1
|
Afsharpaiman S, Zare M, Yasemi M, Jamialahmadi T, Sahebkar A. The Prevalence of Infectious Keratitis after Keratorefractive Surgery: A Systematic Review and Meta-Analysis Study. J Ophthalmol 2020; 2020:6329321. [PMID: 32774907 PMCID: PMC7407012 DOI: 10.1155/2020/6329321] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2020] [Accepted: 04/24/2020] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND The keratorefractive surgeries (KRS) are one of the most common ocular surgeries. One of the dangerous complications of these surgeries is infectious keratitis (IK), which is the second cause of blindness after cataract surgery. The purpose of this study was to estimate the prevalence of IK after KRS in different parts of the world. METHODS In order to obtain relevant studies, all national and international databases including IranMedex, SID, Magiran, IranDoc, Medlib, ScienceDirect, PubMed, Scopus, Cochrane, Embase, Web of Science, and Google Scholar were searched using standard keywords. RESULTS IK prevalence after KRS was 0.000496% (0.000145% for the left eye and 0.000149% for the right eye). IK prevalence after KRS in the United States, Europe, and Asia was 0.000667%, 0.000473%, and 0.000045%, respectively, in all of which the common microorganisms were Staphylococci. Meta-regression showed no significant association between IK after KRS and either sample size or publication year of the studies. IK prevalence after KRS in the right eye was more than that in the left one. Also, the probability of IK incidence after LASIK surgery was more than PRK and LASEK. In the evaluation of continents, IK after KRS in the United States was more frequent compared with Europe and Asia. CONCLUSIONS This study provided data as to the overall prevalence of IK following KRS and its variations according to the types of eye, surgery, pathogenic microorganism, and geographical location.
Collapse
Affiliation(s)
- Shahla Afsharpaiman
- Health Research Center, Life Style Institute, Bagiyatallah University of Medical Sciences, Tehran, Iran
| | - Musa Zare
- Department of Ophthalmology, Jahrom University of Medical Sciences, Jahrom, Iran
| | - Masoud Yasemi
- Health Research Center, Life Style Institute, Bagiyatallah University of Medical Sciences, Tehran, Iran
| | - Tannaz Jamialahmadi
- Department of Food Science and Technology, Quchan Branch, Islamic Azad University, Quchan, Iran
- Department of Nutrition, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Amirhossein Sahebkar
- Halal Research Center of IRI, FDA, Tehran, Iran
- Biotechnology Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran
- Neurogenic Inflammation Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| |
Collapse
|
2
|
Shortt AJ, Allan BDS, Evans JR. Laser-assisted in-situ keratomileusis (LASIK) versus photorefractive keratectomy (PRK) for myopia. Cochrane Database Syst Rev 2013:CD005135. [PMID: 23440799 DOI: 10.1002/14651858.cd005135.pub3] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Myopia (also known as short-sightedness or near-sightedness) is an ocular condition in which the refractive power of the eye is greater than is required, resulting in light from distant objects being focused in front of the retina instead of directly on it. The two most commonly used surgical techniques to permanently correct myopia are photorefractive keratectomy (PRK) and laser-assisted in-situ keratomileusis (LASIK). OBJECTIVES To compare the effectiveness and safety of LASIK and PRK for correction of myopia by examining post-treatment uncorrected visual acuity, refractive outcome, loss of best spectacle-corrected visual acuity, pain scores, flap complications in LASIK, subepithelial haze, adverse events, quality of life indices and higher order aberrations. SEARCH METHODS We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2012, Issue 11), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to November 2012), EMBASE (January 1980 to November 2012), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to November 2012), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 15 November 2012. We also searched the reference lists of the studies and the Science Citation Index. SELECTION CRITERIA We included randomised controlled trials comparing LASIK and PRK for the correction of any degree of myopia. DATA COLLECTION AND ANALYSIS Two authors independently assessed trial quality and extracted data. We summarised data using the odds ratio and mean difference. We combined odds ratios using a random-effects model after testing for heterogeneity. MAIN RESULTS We included 13 trials (1135 participants, 1923 eyes) in this review. Nine of these trials randomised eyes to treatment, two trials randomised people to treatment and treated both eyes, and two trials randomised people to treatment and treated one eye. None of the paired trials reported an appropriate paired analysis. We considered the overall quality of evidence to be low for most outcomes because of the risk of bias in the included trials. There was evidence that LASIK gives a faster visual recovery than PRK and is a less painful technique. Results at one year after surgery were comparable: most analyses favoured LASIK but they were not statistically significant. AUTHORS' CONCLUSIONS LASIK gives a faster visual recovery and is a less painful technique than PRK. The two techniques appear to give similar outcomes one year after surgery. Further trials using contemporary techniques are required to determine whether LASIK and PRK as currently practised are equally safe. Randomising eyes to treatment is an efficient design, but only if analysed properly. In future trials, more efforts could be made to mask the assessment of outcome.
Collapse
Affiliation(s)
- Alex J Shortt
- The Moorfields Eye Hospital/UCL Institute of Ophthalmology National Institute for Health Research Biomedical Research Centre,London, UK.
| | | | | |
Collapse
|
3
|
Abstract
PURPOSE To report a patient who presented an infectious keratitis 4 years after laser in situ keratomileusis (LASIK) without any other predisposing risk factor than the LASIK procedure itself. CASE REPORT We report a 32-year-old man operated by LASIK in January 2006 who presented with infectious keratitis in the OD in April 2010. Clinical examination showed a corneal abscess at 10-o'clock position in the interface and fibrin and Tyndall 4+ in the anterior chamber. Microbiological analysis identified Pseudomonas aeruginosa as the cause of infection. The patient was given ofloxacin, sulfate neomycin, polymyxin B, and prednisolone acetate to be used every 2 h. Treatment led to clinical improvement with resolution of corneal infiltrate. Keratitis with intact epithelium by Pseudomonas can occur up to 4 years after LASIK. CONCLUSIONS LASIK treatment is a predisposing factor for bacterial keratitis even years after surgery. This report demonstrates the importance of continued postoperative vigilance by patient and his/her clinician.
Collapse
|
4
|
A perfluoropolyether corneal inlay for the correction of refractive error. Biomaterials 2011; 32:3158-65. [PMID: 21306775 DOI: 10.1016/j.biomaterials.2011.01.047] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2010] [Accepted: 01/12/2011] [Indexed: 11/24/2022]
Abstract
This study assessed the long-term biological response of a perfluoropolyether-based polymer developed as a corneal inlay to correct refractive error. The polymer formulation met chemical and physical specifications and was non-cytotoxic when tested using standard in vitro techniques. It was cast into small microporous membranes that were implanted as inlays into corneas of rabbits (n = 5) and unsighted humans (n = 5 + 1 surgical control) which were monitored for up to 23 and 48 months respectively. Overall, the inlays were well tolerated during study period with the corneas remaining clear and holding a normal tear film and with no increased vascularisation or redness recorded. Inlays in three human corneas continued past 48 months without sequelae. Inlays in two human corneas were removed early due to small, focal erosions developing 5 and 24 months post-implantation. Polymer inlays maintained their integrity and corneal position for the study duration although the optical clarity of the inlays reduced slowly with time. Inlays induced corneal curvature changes in human subjects that showed stability with time and the refractive effect was reversed when the inlay was removed. Outcomes showed the potential of a perfluoropolyether inlay as a biologically acceptable corneal implant with which to provide stable correction of refractive error.
Collapse
|
5
|
Garg P, Chaurasia S, Vaddavalli PK, Muralidhar R, Mittal V, Gopinathan U. Microbial Keratitis After LASIK. J Refract Surg 2010; 26:209-16. [DOI: 10.3928/1081597x-20100224-07] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2008] [Accepted: 04/02/2009] [Indexed: 11/20/2022]
|
6
|
Llovet F, de Rojas V, Interlandi E, Martín C, Cobo-Soriano R, Ortega-Usobiaga J, Baviera J. Infectious keratitis in 204 586 LASIK procedures. Ophthalmology 2009; 117:232-8.e1-4. [PMID: 20006909 DOI: 10.1016/j.ophtha.2009.07.011] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2008] [Revised: 06/30/2009] [Accepted: 07/06/2009] [Indexed: 10/20/2022] Open
Abstract
PURPOSE To investigate the incidence, culture results, risk factors, and visual outcomes of infectious keratitis after LASIK, and examine treatment strategies. DESIGN Retrospective study. PARTICIPANTS We included 107 613 patients who underwent LASIK at Clínica Baviera (Instituto Oftalmológico Europeo, Spain) from September 2002 to May 2008. METHODS The medical records of post-LASIK patients (204 586 eyes) were reviewed to identify cases of infectious keratitis. Incidence, risk factors, clinical course, days to diagnosis, medical and surgical treatment, and final visual outcomes were recorded. MAIN OUTCOME MEASURES Incidence of post-LASIK infectious keratitis, culture results, response to treatment, and visual outcome. RESULTS Post-LASIK infectious keratitis was diagnosed in 72 eyes from 63 patients. Onset of infection was early (within 7 days after surgery) in 62.5% of cases. Cultures were positive in 21 of 54 cases in which samples were taken. The most frequently isolated microorganism was Staphylococcus epidermidis (9 cases). Immediate flap lifting and irrigation with antibiotics was performed in 54 eyes; late flap lifting was subsequently required in 10 out of 18 cases initially treated with topical antibiotics alone. One case required flap amputation owing to flap necrosis. Final best spectacle-corrected visual acuity (BSCVA) was >or=20/20 in 38 cases (52.7%) and >or=20/40 in 67 cases (93.05%); final BSCVA was <20/40 in 5 cases (6.94%). CONCLUSIONS The incidence of post-LASIK infectious keratitis was 0.035% per procedure. Infectious keratitis after LASIK is a potentially vision-threatening complication. The appearance of infections in asymptomatic patients highlights the need for a proper schedule of follow-up appointments. Prompt and aggressive management of this LASIK complication with early flap lifting, scraping, culture, and irrigation with antibiotics is strongly recommended. Proper management can result in preserving useful vision. FINANCIAL DISCLOSURE(S) The authors have no proprietary or commercial interest in any of the materials discussed in this article.
Collapse
|
7
|
Mimura T, Azar DT. Current Concepts, Classification, and History of Refractive Surgery. Ophthalmology 2009. [DOI: 10.1016/b978-0-323-04332-8.00015-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022] Open
|
8
|
|
9
|
Jongsareejit A. Clinical Results With the Medennium Phakic Refractive Lens for the Correction of High Myopia. J Refract Surg 2006; 22:890-7. [PMID: 17124884 DOI: 10.3928/1081-597x-20061101-09] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the predictability, safety, stability, complications, and biocompatibility of the phakic refractive lens (PRL) as a posterior chamber intraocular lens to correct high myopia. METHODS Fifty eyes of 31 patients who underwent posterior chamber PRL implantation were evaluated prospectively. Mean preoperative myopia was -12.54 +/- 4.22 diopters (D) (range: -4.50 to -23.50 D) and mean astigmatic refractive power was -1.38 +/- 1.24 D (range: -1.00 to -4.50 D). Surgical implantation was performed through a 3.0- to 4.0-mm clear cornea sutureless incision using parabulbar (sub-Tenon's) anesthesia. Intra- and postoperative complications were recorded. RESULTS Three months after surgery, the mean spherical equivalent refraction was -0.21 +/- 0.42 D (range: +1.00 to -1.75 D). At 6 and 12 months, mean spherical equivalent refraction was -0.23 +/- 0.38 D (range: 0 to -1.25 D). At the last examination, uncorrected visual acuity was > or = 20/40 in 41 (82%) eyes and > or = 20/20 in 22 (44%) eyes. Best spectacle-corrected visual acuity (BSCVA) was > or = 20/40 in 42 (84%) eyes and > or = 20/20 in 27 (54%) eyes. Comparison of pre- and postoperative BSCVA at 12 months showed that 12 (36.4%) of 33 eyes gained > or =1 lines of BSCVA and 7 (21.2%) of 33 eyes gained > or =2 lines. One (2%) eye developed anterior subcapsular cataract requiring lens exchange, and 1 (2%) eye developed acute angle closure glaucoma requiring YAG-iridotomy. One (2%) eye developed macular hemorrhage. CONCLUSIONS At 6 months and 1 and 2 years, PRL implantation yielded encouraging visual and refractive results with excellent biocompatibility. The efficacy, stability, and short-term safety of this lens was established. Serious complications, such as cataract and acute angle closure glaucoma, may occur, and long-term safety needs to be evaluated.
Collapse
Affiliation(s)
- Amporn Jongsareejit
- Department of Ophtholmology and Visual Sciences, Prasat Neurological Institute, Bangkok, Thailand.
| |
Collapse
|
10
|
Shortt AJ, Allan BDS. Photorefractive keratectomy (PRK) versus laser-assisted in-situ keratomileusis (LASIK) for myopia. Cochrane Database Syst Rev 2006:CD005135. [PMID: 16625626 DOI: 10.1002/14651858.cd005135.pub2] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
BACKGROUND Myopia (also known as short-sightedness or near-sightedness) is an ocular condition in which the refractive power of the eye is greater than is required, resulting in light from distant objects being focused in front of the retina instead of directly on it. The two most commonly used surgical techniques to permanently correct myopia are photorefractive keratectomy (PRK) and laser-assisted in-situ keratomileusis (LASIK). OBJECTIVES The aim of this review was to compare the effectiveness and safety of PRK and LASIK for correction of myopia. SEARCH STRATEGY We searched the Cochrane Central Register of Controlled Trials (CENTRAL) in The Cochrane Library (2005, Issue 3), MEDLINE (1966 to September 2005), EMBASE (1980 to September 2005) and LILACs (1982 to 3 November 2005). We also searched the reference lists of the studies and the Science Citation Index. SELECTION CRITERIA We included randomised controlled trials comparing PRK and LASIK for correction of any degree of myopia. We also included data on adverse events from prospective multicentre consecutive case series in the Food and Drugs Administration (FDA) trials database (http//www.fda.gov/cdrh/LASIK/lasers.htm). DATA COLLECTION AND ANALYSIS Two authors independently assessed trial quality and extracted data. Data were summarised using odds ratio and mean difference. Odds ratios were combined using a random-effects model after testing for heterogeneity. MAIN RESULTS This review included six randomised controlled trials involving a total of 417 eyes, of which 201 were treated with PRK and 216 with LASIK. We found that although LASIK gives a faster visual recovery than PRK, the effectiveness of these two procedures is comparable. We found some evidence that LASIK may be less likely than PRK to result in loss of best spectacle-corrected visual acuity. AUTHORS' CONCLUSIONS LASIK gives a faster visual recovery than PRK but the effectiveness of these two procedures is comparable. Further trials using contemporary techniques are required to determine whether LASIK and PRK are equally safe.
Collapse
Affiliation(s)
- A J Shortt
- Moorfields Eye Hospital, 162 City Road, London, UK, EC1V 2PD.
| | | |
Collapse
|
11
|
Fernández DC, Niazy AM, Kurtz RM, Djotyan GP, Juhasz T. A finite element model for ultrafast laser-lamellar keratoplasty. Ann Biomed Eng 2006; 34:169-83. [PMID: 16474919 DOI: 10.1007/s10439-005-9014-3] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2005] [Accepted: 08/22/2005] [Indexed: 11/28/2022]
Abstract
A biomechanical model of the human cornea is employed in a finite element formulation for simulating the effects of Ultrafast Laser-Lamellar Keratoplasty. Several computer simulations were conducted to study curvature changes of the central corneal zone under various physiological and surgical factors. These factors included the combined effect of corneal flap and residual stromal bed thickness on corneal curvature; the effect of the shape of the lenticle on the surgical procedure outcomes and the effect of flap thickness on stress distribution in the cornea. The results were validated by comparing computed refractive power changes with clinical results. The effect of flap thickness on the amount of central flattening indicates that for flap thickness values 28% over the corneal thickness, central corneal flattening decreases. Moreover, the change in corneal curvature induced by subtraction of a plano-convex lenticle under a uniform flap, naturally imply a smaller change in the structure of the anterior layers of the cornea, but a bigger deformation in the structure of the posterior layers that are left behind the resection of the lenticle. In addition, the model also verified that the corneal curvature increased peripherally with simultaneous thinning centrally after subtraction of corneal tissue. This result shows that not only the treated zone is affected by the surgery, indicating the important role of the biomechanical response of the corneal tissue to refractive surgery, which is unaccounted for in current ablation algorithms. The results illustrate the potentialities of finite element modeling as an aid to the surgeon in evaluating variables.
Collapse
Affiliation(s)
- D Cabrera Fernández
- Bascom Palmer Eye Institute, Department of Ophthalmology, University of Miami Miller School of Medicine, Miami, FL 33136, USA.
| | | | | | | | | |
Collapse
|
12
|
Cabrera Fernández D, Niazy AM, Kurtz RM, Djotyan GP, Juhasz T. Finite element analysis applied to cornea reshaping. JOURNAL OF BIOMEDICAL OPTICS 2005; 10:064018. [PMID: 16409083 DOI: 10.1117/1.2136149] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
A 2-D finite element model of the cornea is developed to simulate corneal reshaping and the resulting deformation induced by refractive surgery. In the numerical simulations, linear and nonlinear elastic models are applied when stiffness inhomogeneities varying with depth are considered. Multiple simulations are created that employ different geometric configurations for the removal of the corneal tissue. Side-by-side comparisons of the different constitutive laws are also performed. To facilitate the comparison, the material property constants are identified from the same experimental data, which are obtained from mechanical tests on corneal strips and membrane inflation experiments. We then validate the resulting models by comparing computed refractive power changes with clinical results. Tissue deformations created by simulated corneal tissue removal using finite elements are consistent with clinically observed postsurgical results. The model developed provides a much more predictable refractive outcome when the stiffness inhomogeneities of the cornea and nonlinearities of the deformations are included in the simulations. Finite element analysis is a useful tool for modeling surgical effects on the cornea and developing a better understanding of the biomechanics of the cornea. The creation of patient-specific simulations would allow surgical outcomes to be predicted based on individualized finite element models.
Collapse
Affiliation(s)
- Delia Cabrera Fernández
- University of Miami, Department of Ophthalmology, Miller School of Medicine, Bascom Palmer Eye Institute, Miami, Florida 33136, USA.
| | | | | | | | | |
Collapse
|
13
|
Donnenfeld ED, Kim T, Holland EJ, Azar DT, Palmon FR, Rubenstein JB, Daya S, Yoo SH. ASCRS White Paper. J Cataract Refract Surg 2005; 31:2008-11. [PMID: 16338575 DOI: 10.1016/j.jcrs.2005.10.030] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/05/2005] [Indexed: 11/29/2022]
|
14
|
Taneri S, Feit R, Azar DT. Safety, efficacy, and stability indices of LASEK correction in moderate myopia and astigmatism. J Cataract Refract Surg 2004; 30:2130-7. [PMID: 15474826 DOI: 10.1016/j.jcrs.2004.02.070] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/18/2004] [Indexed: 11/30/2022]
Abstract
PURPOSE To evaluate the visual outcomes and complications in low to moderate levels of myopia and astigmatism treated with laser-assisted subepithelial keratectomy (LASEK) with a focus on postoperative recovery. SETTING Massachusetts Eye and Ear Infirmary, Harvard Medical School, Boston, Massachusetts, USA. METHODS A retrospective analysis of a case series of eyes treated with LASEK from 1996 to July 2002 with a follow-up of 2 years was performed. The LASEK technique involved creating an epithelial flap with 25 to 45 seconds of exposure to 20% alcohol, ablating the corneal surface using 3 different excimer lasers and nomogram adjustment, and repositioning the flap and applying a bandage contact lens. The main outcome measures were uncorrected visual acuity (UCVA), efficacy index, manifest refraction, best spectacle-corrected visual acuity (BSCVA), safety index, retreatment rate, and complications. RESULTS One hundred seventy-one eyes (85 right eyes and 86 left eyes) of 105 patients were studied. Preoperatively, the mean spherical equivalent was -2.99 diopters (D) +/- 1.43 (SD) (range -0.38 to -7.75 D) and the mean cylinder, -0.78 +/- 0.73 D. The UCVA ranged from 20/800 to 20/32, and the BSCVA ranged from 20/63 to 20/16; the median was 20/20. One week postoperatively, 96% of eyes had a UCVA of 20/40 or better but definitive visual recovery took more than 4 weeks in some eyes. Approximately 95% of eyes were within +/-1.0 D of emmetropia after 4 to 52 weeks; the remaining 5% did not show major deviations. At 4 to 52 weeks, only 1 eye was overcorrected by more than 1.0 D of manifest refraction. The safety index remained close to 1.0 for the follow-up after 4 weeks. The efficacy index displayed a plateau at 0.9 from 1 month to 1 year. No serious complication (including recurrent erosion syndrome) was encountered. The mean follow-up was 31 weeks, and the retreatment rate was 2.9% up to 2 years of follow-up. CONCLUSIONS The long-term safety and effectiveness of LASEK for the correction of low to moderate myopia and astigmatism were demonstrated. The treatment effect stabilized after 4 weeks.
Collapse
Affiliation(s)
- Suphi Taneri
- Department of Ophthalmology, Massachusetts Eye and Ear Infirmary and the Schepens Eye Research Institute, Harvard Medical School, Boston, MA 02114, USA
| | | | | |
Collapse
|
15
|
Solomon R, Donnenfeld ED, Azar DT, Holland EJ, Palmon FR, Pflugfelder SC, Rubenstein JB. Infectious keratitis after laser in situ keratomileusis: Results of an ASCRS survey. J Cataract Refract Surg 2003; 29:2001-6. [PMID: 14604725 DOI: 10.1016/s0886-3350(03)00512-1] [Citation(s) in RCA: 89] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
To investigate the incidence, culture results, treatment, and visual outcomes of infectious keratitis after laser in situ keratomileusis (LASIK) worldwide, the Cornea Clinical Committee of the American Society of Cataract and Refractive Surgery (ASCRS) contacted 8600 United States and international ASCRS members by e-mail and asked them to respond to a questionnaire about post-LASIK infectious keratitis. One hundred sixteen infections were reported by 56 LASIK surgeons who had performed an estimated 338 550 procedures. Seventy-six cases presented in the first week after surgery, 7 during the second week, 17 between the second and fourth weeks, and 16 after 1 month. Forty-seven cases were not diagnosed on initial presentation. The most common organisms cultured were atypical mycobacteria and staphylococci. Empiric therapy is not recommended as most of the organisms are opportunistic and not responsive to conventional therapy. Flap elevation and culturing should be performed when post-LASIK infectious keratitis is suspected.
Collapse
Affiliation(s)
- Renée Solomon
- Ophthalmic Consultants of Long Island, Rockville Centre, East Meadow, New York, USA
| | | | | | | | | | | | | |
Collapse
|
16
|
Solomon R, Donnenfeld ED, Perry HD, Doshi S, Biser S. Slitlamp stretching of the corneal flap after laser in situ keratomileusis to reduce corneal striae. J Cataract Refract Surg 2003; 29:1292-6. [PMID: 12900234 DOI: 10.1016/s0886-3350(03)00046-4] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
PURPOSE To examine the efficacy of treating immediate postoperative corneal striae and poor flap alignment by stretching the corneal flap at the slitlamp with a cotton-tip applicator and compare the results using this technique with those using the conventional technique of refloating the flap with balanced salt solution (BSS(R)). SETTING TLC Laser Eye Center, Garden City, New York, USA. METHODS Charts of 7154 eyes having laser in situ keratomileusis (LASIK) were reviewed retrospectively. During the 11 months prior to January 1, 2000, 3516 eyes had LASIK. Patients with flap striae or a malpositioned flap at the immediate slitlamp evaluation were treated by refloating the flap (Group A). During the 11 months subsequent to January 1, 2000, 3638 eyes had LASIK. Patients with flap striae or a malpositioned flap at the immediate slitlamp evaluation were treated by flap stretching with a cotton-tip applicator (Group B). The number of eyes that required retreatment for flap striae was analyzed. RESULTS Twenty-nine eyes in Group A (0.82%) required retreatment for visually significant flap striae after day 1, and 11 eyes in Group B (0.30%) required retreatment. A loss of best corrected visual acuity occurred in 3 Group A eyes and 2 Group B eyes. CONCLUSIONS During the immediate postoperative period, stretching the flap with a cotton-tip applicator was a simple, safe, and effective technique for reducing visually significant flap striae. Unlike refloating the flap with BSS, flap stretching at the slitlamp does not require additional anesthesia, exposure time, or dehydration of the ocular surface.
Collapse
Affiliation(s)
- Renée Solomon
- Ophthalmic Consultants of Long Island, Rockville Centre, New York, USA
| | | | | | | | | |
Collapse
|
17
|
Abstract
PURPOSE To report the occurrence, management, and outcome of late-onset traumatic dehiscence and dislocation of laser in situ keratomileusis (LASIK) flaps. METHODS Two interventional case reports of patients with late-onset LASIK corneal flap dislocation after ocular trauma occurring at 7 and 26 months after surgery, respectively. RESULTS The flaps were lifted, stretched, and repositioned after irrigation and scraping of the stromal bed and the underside of the flap. A bandage contact lens was placed, and topical antibiotic and corticosteroids were given postoperatively. The dislocated corneal flaps were successfully repositioned in both cases. The patient whose dislocated flap was repositioned 4 hours after the trauma recovered his uncorrected visual acuity (UCVA) of 20/20 1 week after the procedure and had a well-positioned flap with a clear interface. The patient who was managed 48 hours after the injury required repeat flap repositioning at 10 and 24 days after the initial procedure for treatment of persistent folds and striae in the visual axis. His uncorrected visual acuity 2 weeks after the third flap repositioning was 20/40 + 2. Diffuse lamellar keratitis developed in both patients that resolved with the use of topical corticosteroids. CONCLUSION Laser in situ keratomileusis corneal flaps are vulnerable to traumatic dehiscence and dislocation, which can occur more than 2 years after the procedure.
Collapse
Affiliation(s)
- Joseph Anthony J Tumbocon
- Department of Ophthalmology, Toronto Western Hospital, University of Toronto, Toronto, Ontario, Canada
| | | | | | | |
Collapse
|
18
|
Donnenfeld ED, Solomon R, Biser S. Laser in situ keratomileusis after penetrating keratoplasty. Int Ophthalmol Clin 2002; 42:67-87. [PMID: 12409923 DOI: 10.1097/00004397-200210000-00008] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Affiliation(s)
- Eric D Donnenfeld
- Ophthalmic Consultants of Long Island, Rockville, Centre, NY 11570, USA
| | | | | |
Collapse
|
19
|
Abstract
PURPOSE Some case reports have shown that abnormal focal steepening of the cornea appears to cause monocular diplopia by prismatic effect. The purpose of this study was to ascertain prospectively if the pattern of corneal distortion was related specifically to persistent monocular diplopia. METHODS We selected 16 visually normal eyes (controls) and two groups of volunteers in which abnormal focal steepening of the cornea was expected to be found: 40 eyes of 20 volunteers who wore rigid gas-permeable contact lenses (RGP) for myopia and 10 eyes of seven patients with keratoconus. New charts that consisted of white dials on a black background were prepared for detection and measurement of secondary images. Any secondary image that could not be eliminated by any trial lens correction was defined as a persistent secondary image, using the charts. Corneal topography from all subjects was classified: round or oval, symmetric or asymmetric bowtie, abnormal focal steepening accompanied by contact lens-induced corneal warpage or keratoconus, or amorphous. We analyzed the relationship between the persistent secondary image and the corneal topographical patterns. RESULTS A persistent secondary image was detected from seven eyes of RGP wearers and all keratoconus eyes. All corneal topographies of the seven RGP eyes with a persistent secondary image showed abnormal focal steepening related to contact lens-induced corneal warpage. The direction of the persistent secondary image was approximately consistent with the location of the focal steepening as seen on the corneal topography. CONCLUSION Abnormal focal steepening of the cornea that appeared to produce a prismatic difference between two parts of the cornea was specifically related to persistent monocular diplopia.
Collapse
Affiliation(s)
- Kazuo Takei
- Department of Ophthalmology, Institute of Clinical Medicine, University of Tsukuba, Japan.
| |
Collapse
|
20
|
Abstract
PURPOSE To evaluate the efficacy, safety, and biocompatibility of a collagen polymer implantable contact lens (ICL) (Staar Collamer) as a posterior chamber phakic intraocular lens (IOL) to correct high myopia. SETTING Departments of Ophthalmology, Helsinki University Central Hospital, Helsinki, and Tampere University Hospital, Tampere, Finland. METHODS A Staar Collamer posterior chamber phakic IOL was implanted in 38 eyes of 22 patients with a mean age of 39 years (range 24 to 54 years). The mean preoperative myopia was -15.10 diopters (D) (range -7.75 to -29.00 D). Surgical implantation was performed through a 3.0 mm clear corneal sutureless incision using paraocular anesthesia. The patients were followed clinically up to 3 years. The mean follow-up was 13.6 months (range 6 to 24 months) for refractive data and 22.3 months (range 6 to 35 months) for complications. The possible inflammatory response to the ICL was measured using a laser flare meter in 12 eyes. RESULTS Postoperatively, all eyes had a significant increase in uncorrected visual acuity, allowing all but 3 patients (5 eyes) to manage most activities without spectacles. The mean spherical equivalent refraction at the last examination was -2.00 D +/- 2.48 (SD) (range +0.13 to -13.00 D), within +/-1.00 D of the targeted refraction in 31 eyes (81.6%) and within +/-0.50 D in 27 eyes (71.1%). In eyes in which the preoperative myopia was less than -18.00 D (n = 28), the achieved refraction was within +/-1.00 D of the intended refraction in 27 eyes (96.4%) and within +/-0.50 D in 24 eyes (85.7%). The refraction remained stable with a statistically insignificant change (P >.05) at each interval during the follow-up. The best corrected visual acuity (BCVA) improved by 1 or more lines in 23 of 32 eyes (71.9%) at 1 year. Two eyes (6.3%) lost 1 line of BCVA. Laser flare photometry showed normal aqueous flare values (11.71 +/- 6.61 photon counts/ms) in the 12 eyes measured at least 6 months after ICL implantation. Pupillary block glaucoma requiring surgical intervention occurred in 3 patients (7.9%). One patient (2.6%) developed cataract 1.5 years after ICL implantation; both ICLs were removed, and the refractive errors were corrected by lensectomy and implantation of low-power posterior chamber IOLs. One patient (2.6%) showed progression of dry macular degeneration at 17 months. CONCLUSION At 1 year, ICL implantation had good visual and refractive results with excellent biocompatibility. Long-term follow-up is required to confirm that significant complications do not occur in most patients over time.
Collapse
Affiliation(s)
- Risto J Uusitalo
- Helsinki University Eye Hospital, PO Box 220, 00029 HUS, Helsinki, Finland.
| | | | | | | |
Collapse
|
21
|
Pallikaris IG, Kymionis GD, Astyrakakis NI. Corneal ectasia induced by laser in situ keratomileusis. J Cataract Refract Surg 2001; 27:1796-802. [PMID: 11709254 DOI: 10.1016/s0886-3350(01)01090-2] [Citation(s) in RCA: 303] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
PURPOSE To identify factors that can lead to corneal ectasia after laser in situ keratomileusis (LASIK). SETTING University refractive surgery center. METHODS In this retrospective study, the charts of all patients (2873 eyes) who had LASIK between May 1995 and November 1999 were reviewed. Fourteen patients (19 eyes, 0.66%) developed post-LASIK ectasia. The mean follow-up was 16.32 months (range 6 to 42 months). RESULTS No patient with an attempted correction less than 8.00 diopters or a residual corneal bed thickness greater than 325 microm experienced post-LASIK ectasia. There was a statistically significant positive correlation between corneal residual bed thickness and increasing patient age. CONCLUSION Despite the limitations of the small sample size, the study's results suggest that parameters besides residual corneal bed thickness (eg, age, attempted correction) may have to be considered to avoid post-LASIK ectasia.
Collapse
Affiliation(s)
- I G Pallikaris
- Department of Ophthalmology, Vardinoyannion Eye Institute of Crete, University of Crete, Heraklio, Greece
| | | | | |
Collapse
|
22
|
Pisella PJ, Auzerie O, Bokobza Y, Debbasch C, Baudouin C. Evaluation of corneal stromal changes in vivo after laser in situ keratomileusis with confocal microscopy. Ophthalmology 2001; 108:1744-50. [PMID: 11581044 DOI: 10.1016/s0161-6420(01)00771-0] [Citation(s) in RCA: 87] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
PURPOSE To assess by in vivo confocal microscopy the modifications of the corneal stroma after laser in situ keratomileusis (LASIK) for myopia. DESIGN Nonrandomized comparative (self-controlled) trial. PARTICIPANTS Sixteen eyes of 13 patients were examined before surgery and at days 8, 30, and 90, and 9 eyes were examined at 6 months postoperatively using an in vivo confocal microscope. TESTING/INTERVENTION: Stromal morphologic changes, keratocyte density, flap thickness, and subclinical haze were evaluated and compared at different time points. LASIK was performed with a Flapmaker microkeratome (Solan Ophthalmic products, Jacksonville, FL) and a Lasersight LSX excimer laser (LaserSight Technologies Inc., Winter Park, FL). MAIN OUTCOME MEASURE Confocal microscopy results. RESULTS Microfolds at the Bowman's layer were found in most eyes, as well as variable reflectivity particles (pa) located at the interface level in all eyes examined postoperatively. The density of these particles significantly decreased with time with, respectively, 504 +/- 101 pa/mm2 at day 8 and 380 +/- 111 pa/mm2 at day 30 (P = 0.003), 332 +/- 100 pa/mm2 at month 3 and 312 +/- 40 pa/mm2 at month 6. The mean flap and the activated-cells area thicknesses were, respectively, 102 +/- 26 microm and 61 +/- 19 microm and showed significant negative correlation (P < 0.0001). The intensity of the added peak (47.3 microm 8.6%), corresponding to the subclinical haze, realized by Z-scan measure, was also negatively correlated with flap thickness (P = 0.01). Keratocyte (k) density quantified in the posterior stroma significantly increased from day 0 (480 +/- 67 k/mm2) to day 8 (701 +/- 41 k/mm2, P < 0.0001 compared with day 0) and day 30 (917 +/- 143 k/mm2, P = 0.0006, compared with day 0) but significantly decreased at 3 months postoperatively (597 +/- 56 k/mm2, P < 0.0001 compared with day 30) to reach the initial level at month 6 (502 +/- 41 k/mm2, nonsignificant compared with day 0). There was no correlation between preoperative or postoperative spherical equivalent and the density of particles, keratocytes, and the haze intensity. CONCLUSIONS This study confirms the presence of microfolds and particles at the interface level, as well as subclinical impairment. Evaluation of keratocyte density constitutes a major contribution of confocal microscopy toward an understanding of the keratocyte response to corneal wound healing after corneal refractive surgery. Moreover, flap thickness seems to be involved in the postoperative cellular activation with a higher response when thin.
Collapse
Affiliation(s)
- P J Pisella
- Department of Ophthalmology, Ambroise Paré Hôpital, AP-HP, Quinze-Vingts National Hospital University Paris-V, France
| | | | | | | | | |
Collapse
|
23
|
Tole DM, McCarty DJ, Couper T, Taylor HR. Comparison of Laser in situ Keratomileusis and Photorefractive Keratectomy for the Correction of Myopia of -6.00 Diopters or Less. J Refract Surg 2001; 17:46-54. [PMID: 11201777 DOI: 10.3928/1081-597x-20010101-06] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the safety and efficacy of laser in situ keratomileusis (LASIK) compared to photorefractive keratectomy (PRK) for the correction of low or moderate myopia (-0.50 to -6.00 D) at 6 months after surgery. METHODS The study population comprised a non-randomized consecutive series of 622 eyes of 392 patients who were treated with the Nidek EC-5000 excimer laser. LASIK was performed using the ACS Chiron microkeratome on 314 eyes and surface PRK on 308 eyes. All patients were treated using a standard protocol, then assessed at 1, 3, and 6 months postoperatively. RESULTS Forty-four percent of the LASIK group and 67% of the PRK group attended their 6-month examination. Eighty percent of patients (111 eyes) after LASIK and 65% (136 eyes) after PRK had an uncorrected visual acuity of 20/20 or better. Spherical equivalent refraction was within +/-0.50 D of intended refraction in 78% (109 eyes) for LASIK and 82% (170 eyes) for PRK. Loss of two more lines of best spectacle-corrected visual acuity at 6 months occurred in 1.4% (2 eyes) of the LASIK group and 1.0% (2 eyes) of the PRK group. CONCLUSION At 1 month follow-up, the percentage of eyes that achieved 20/20 uncorrected visual acuity was greater in the LASIK group than in the PRK group. At 6 months, visual and refractive outcomes of LASIK and PRK were similar. Although flap related complications occurred only after LASIK, the overall risk of loss of best spectacle-corrected visual acuity was not significantly greater than for PRK.
Collapse
Affiliation(s)
- D M Tole
- Centre for Eye Research Australia, University of Melbourne, Royal Victorian Eye and Ear Hospital
| | | | | | | |
Collapse
|
24
|
Melki SA, Talamo JH, Demetriades AM, Jabbur NS, Essepian JP, O'Brien TP, Azar DT. Late traumatic dislocation of laser in situ keratomileusis corneal flaps. Ophthalmology 2000; 107:2136-9. [PMID: 11097584 DOI: 10.1016/s0161-6420(00)00405-x] [Citation(s) in RCA: 81] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
PURPOSE To report the management and outcome of late-onset traumatic dislocation of laser in situ keratomileusis (LASIK) flaps. DESIGN Retrospective, observational case series. PARTICIPANTS Four patients with late-onset LASIK flap dislocation occurring after mechanical trauma at various intervals (10 days-2 months) after the procedure. INTERVENTION In all cases of postoperative traumatic LASIK flap dislocation, the flap was refloated with scraping and irrigation of the underlying stromal bed within 12 hours of the injury. A bandage contact lens was placed, and a regimen including topical antibiotics and corticosteroids was instituted in all cases. MAIN OUTCOME MEASURES Best spectacle-corrected visual acuity and complications associated with the surgery were monitored. RESULTS Postoperative follow-up ranged from 4 to 21 months. Nonprogressive epithelial ingrowth was noted in one patient and diffuse lamellar keratitis developed in another patient. All patients recovered pretrauma spectacle-corrected visual acuity. CONCLUSIONS Corneal LASIK flaps are prone to mechanical dislocation as late as 2 months after the procedure. Appropriate management results in recovery of optimal visual outcomes.
Collapse
Affiliation(s)
- S A Melki
- Massachusetts Eye & Ear Infirmary, Boston, Massachusetts, USA
| | | | | | | | | | | | | |
Collapse
|
25
|
Moilanen JA, Vesaluoma MH, Vesti ET, Vaajoensuu TP, Partinen MM, Tervo TM. Photorefractive Keratectomy in Ophthalmic Residents. J Refract Surg 2000; 16:731-8. [PMID: 11110314 DOI: 10.3928/1081-597x-20001101-09] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To find out how ophthalmologists themselves experience the correction of myopia after photorefractive keratectomy. Visuomotor functions were of special interest. METHODS Four ophthalmology residents and one medical engineer underwent photorefractive keratectomy for myopia. Objective measurements including refraction, corneal topography, perimetry, contrast sensitivity, pattern visual evoked potentials, in vivo confocal microscopy, and a car driving simulator test were performed preoperatively, postoperatively, and at 6 months. Subjective evaluation was reported. RESULTS Performing ophthalmological examinations and microsurgery without spectacles was easier postoperatively and was appreciated by the four ophthalmology residents. Minimal haze formation, good accuracy, and normal performance in the car driving simulator were also observed. Visual fields, contrast sensitivity, and pattern visual evoked potentials did not show changes. Negative observations included postoperative pain for 2 to 4 days, dry eye symptoms, a period of anisometropia between operations, and hypersensitivity of the lids. CONCLUSIONS The four ophthalmic residents were satisfied with the outcome of their refractive surgery. Low to moderate myopic correction did not affect the objective measurements of high and low contrast sensitivity, pattern visual evoked potentials, or simulated car driving in dark illumination.
Collapse
Affiliation(s)
- J A Moilanen
- Department of Ophthalmology, University of Helsinki, Finland.
| | | | | | | | | | | |
Collapse
|
26
|
Rose K, Harper R, Tromans C, Waterman C, Goldberg D, Haggerty C, Tullo A. Quality of life in myopia. Br J Ophthalmol 2000; 84:1031-4. [PMID: 10966960 PMCID: PMC1723631 DOI: 10.1136/bjo.84.9.1031] [Citation(s) in RCA: 101] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
BACKGROUND The safety and predictability of refractive surgery for all degrees of myopia is now becoming established. It is therefore appropriate to evaluate whether there is a patient driven demand for such treatments and, if so, to establish guidelines for its provision within the National Health Service (NHS). METHODS A comparative study was designed to assess the effect of degree of myopia on quality of life ("high" (n = 30) -10.00D, worse eye; "moderate" (n = 40) -4.00 to -9.75D, worse eye; "low" (n = 42) <-4. 00D, worse eye) compared with a group of patients with keratoconus (n = 30) treated by optical correction. Data collection included binocular logMAR visual acuity, Pelli-Robson low contrast letter sensitivity, questionnaires to assess subjective visual function (VF-14) and effect on quality of life (VQOL), and semi-structured interviews. RESULTS There were no significant differences in any of the measures between patients with a high degree of myopia and those with keratoconus, or between those with a low and those with a moderate degree of myopia. However, those with a high degree of myopia had highly significantly poorer logMAR, VF-14, and VQOL scores than those with low and moderate myopia (p<0.001). Interview data supported these findings with patients with a high degree of myopia and those with keratoconus reporting that psychological, cosmetic, practical, and financial factors affected their quality of life. CONCLUSION Compared with low and moderate myopia, patients with a high degree of myopia experience impaired quality of life similar to that of patients with keratoconus. Criteria should therefore be identified to enable those in sufficient need to obtain refractive surgical treatment under the NHS.
Collapse
Affiliation(s)
- K Rose
- Academic Department of Ophthalmology, Manchester Royal Eye Hospital, Manchester M13 9WH
| | | | | | | | | | | | | |
Collapse
|
27
|
|
28
|
Holland SP, Srivannaboon S, Reinstein DZ. Avoiding serious corneal complications of laser assisted in situ keratomileusis and photorefractive keratectomy. Ophthalmology 2000; 107:640-52. [PMID: 10768325 DOI: 10.1016/s0161-6420(99)00131-1] [Citation(s) in RCA: 119] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022] Open
Abstract
OBJECTIVE To identify avoidable factors that can lead to serious complications of laser refractive surgery (photorefractive keratectomy [PRK] and laser assisted in situ keratomileusis [LASIK]). DESIGN Noncomparative case series. PARTICIPANTS Twenty-seven eyes of 19 patients who had undergone either LASIK or PRK with severe complications accrued retrospectively. INTERVENTION Review of clinical records. MAIN OUTCOME MEASURES Symptoms, refractive outcome, and assessment of avoidable factors contributing to the complication. RESULTS Patients were analyzed in four groups: group 1, scarring with ectasia; group 2, unrecognized keratoconus; group 3, flap related LASIK complications; and group 4, multiple retreatments. The 8 eyes with scarring and ectasia presented with the worst vision, 20/400 uncorrected visual acuity and 20/200 best spectacle-corrected visual acuity, with avoidable factors considered as high or difficult prescriptions with multiple retreatments. Four eyes in two patients with possible forme fruste keratoconus showed worsening irregular astigmatism. Laser assisted in situ keratomileusis flap complications included six eyes with partial laser treatment under an incomplete flap with subsequent severe irregular astigmatism. Six eyes in three patients who had undergone an average of three multiple retreatments showed decreased vision with irregular astigmatism. CONCLUSIONS Certain severe complications of laser refractive surgery likely can be avoided by using caution when treating high prescriptions, particularly with retreatments, recognizing early keratoconus and avoiding laser treatment under a partial flap in LASIK.
Collapse
Affiliation(s)
- S P Holland
- Department of Ophthalmology, University of British Columbia, Vancouver, Canada
| | | | | |
Collapse
|
29
|
Sletten KR, Yen KG, Sayegh S, Loesel F, Eckhoff C, Horvath C, Meunier M, Juhasz T, Kurtz RM. An In Vivo Model of Femtosecond Laser Intrastromal Refractive Surgery. Ophthalmic Surg Lasers Imaging Retina 1999. [DOI: 10.3928/1542-8877-19991101-10] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
30
|
Donnenfeld ED, Kornstein HS, Amin A, Speaker MD, Seedor JA, Sforza PD, Landrio LM, Perry HD. Laser in situ keratomileusis for correction of myopia and astigmatism after penetrating keratoplasty. Ophthalmology 1999; 106:1966-74; discussion 1974-5. [PMID: 10519594 DOI: 10.1016/s0161-6420(99)90410-4] [Citation(s) in RCA: 74] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
PURPOSE To determine the safety and effectiveness of laser in situ keratomileusis (LASIK) for visual rehabilitation of residual myopia and astigmatism after penetrating keratoplasty. DESIGN Prospective, noncomparative case series. PARTICIPANTS LASIK was performed on 23 eyes of 22 patients unable to wear glasses or contact lenses after penetrating keratoplasty due to anisometropia, high astigmatism, and/or contact lens-intolerance. METHODS All patients underwent LASIK for visual rehabilitation after penetrating keratoplasty. Uncorrected visual acuity and best spectacle-corrected visual acuity, degree of anisometropia, and corneal transplant integrity were recorded before surgery, as well as at 1 month, 3 months, 6 months, and 12 months after LASIK surgery. RESULTS The mean spherical equivalent before surgery was -7.58+/-4.42 diopters (D), which was reduced to -1.09+/-2.01 D, -0.79+/-1.84 D, -0.77+/-1.25 D, and -1.57+/-1.20 D, respectively, at 1, 3, 6, and 12 months after LASIK. The mean cylinder before surgery was 3.64+/-1.72 D, which was reduced to 1.98+/-1.15 D, 1.64+/-1.14 D, 1.48+/-0.92 D, and 1.29+/-1.04 D, respectively, at 1, 3, 6, and 12 months after LASIK. Spherical equivalent anisometropia was reduced from a mean of 6.88+/-4.4 D to 1.42+/-1.05 D at the final examination. Best-corrected visual acuity remained the same or improved in 21 of 23 eyes and decreased by 1 and 3 lines in 2 patients. There were no surgical flap or corneal transplant complications. CONCLUSIONS LASIK is a viable treatment alternative for myopia and astigmatism after penetrating keratoplasty in patients who are contact lens-intolerant. LASIK is more effective in treating myopia than astigmatism after penetrating keratoplasty.
Collapse
Affiliation(s)
- E D Donnenfeld
- Department of Ophthalmology, North Shore University Hospital, Manhasset, New York 11530, USA
| | | | | | | | | | | | | | | |
Collapse
|
31
|
Abstract
Recent reports of retinal pathology associated with laser refractive surgery are documented. The overall risk of retinal disease following photorefractive keratectomy or laser-assisted in situ keratomileusis is discussed, and the potential causal associations between anterior segment laser and posterior segment pathology are assessed.
Collapse
Affiliation(s)
- D G Charteris
- Vitreoretinal Unit, Moorfields Eye Hospital, London, UK
| |
Collapse
|
32
|
Excimer laser photorefractive keratectomy (PRK) for myopia and astigmatism11Prepared by the Committee on Ophthalmic Procedures Assessment Refractive Surgery Panel, Christopher J. Rapuano, MD, Chair, and approved by the American Academy of Ophthalmology’s Board of Trustees December 14, 1998. Ophthalmology 1999. [DOI: 10.1016/s0161-6420(99)90085-4] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|