2
|
Hasan MM, Eto F, Mamun MA, Sato S, Islam A, Waliullah ASM, Chi DH, Takahashi Y, Kahyo T, Naito Y, Kotani M, Ohmura T, Setou M. Desorption ionization using through-hole alumina membrane offers higher reproducibility than 2,5-dihydroxybenzoic acid, a widely used matrix in Fourier transform ion cyclotron resonance mass spectrometry imaging analysis. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2021; 35:e9076. [PMID: 33651445 DOI: 10.1002/rcm.9076] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Revised: 03/01/2021] [Accepted: 03/01/2021] [Indexed: 06/12/2023]
Abstract
RATIONALE DIUTHAME (desorption ionization using through-hole alumina membrane), a recently developed matrix-free ionization-assisting substrate, was examined for reproducibility in terms of mass accuracy and intensity using standard lipid and mouse brain sections. The impregnation property of DIUTHAME significantly improved the reproducibility of mass accuracy and intensity compared with 2,5-dihydroxybenzoic acid (DHB). METHODS Frozen tissue sections were mounted on indium tin oxide-coated glass slides. DIUTHAME and DHB were applied to individual sections. Subsequently, a solution of a phosphatidylcholine standard, PC(18:2/18:2), was poured onto the DIUTHAME and matrix. Finally, the samples were subjected to laser desorption ionization coupled with Fourier transform ion cyclotron resonance mass spectrometry. The reproducibility was tested by calculating the mean ± standard deviation values of mass errors and intensities of individual ion species. RESULTS Analysis of the PC(18:2/18:2) standard showed significantly (p < 0.01) lower mass error for DIUTHAME-MS than for MALDI-MS. Endogenous PC(36:4) analysis in mouse brain section also showed significantly (p < 0.05) lower mass errors for DIUTHAME-MS. Furthermore, we investigated the mass error of some abundant lipid ions in brain sections and observed similar results. DIUTHAME-MS displayed lower signal intensity in standard PC analysis. Interestingly, it offered higher signal intensities for all the endogenous lipid ions. Lower fluctuations of both mass accuracies and signal intensities were observed in DIUTHAME-MS. CONCLUSIONS Our results demonstrated that DIUTHAME-MS offers higher reproducibility for mass accuracies and intensities than MALDI-MS in both standard lipid and mouse brain tissue analyses. It can potentially be used instead of conventional MALDI-MS and mass spectrometry imaging analyses to achieve highly reproducible data for mass accuracy and intensity.
Collapse
Affiliation(s)
- Md Mahmudul Hasan
- Department of Cellular & Molecular Anatomy, Hamamatsu University School of Medicine, 1-20-1 Handayama, Higashi-ku, Hamamatsu, Shizuoka, 431-3192, Japan
| | - Fumihiro Eto
- Department of Cellular & Molecular Anatomy, Hamamatsu University School of Medicine, 1-20-1 Handayama, Higashi-ku, Hamamatsu, Shizuoka, 431-3192, Japan
| | - Md Al Mamun
- Department of Cellular & Molecular Anatomy, Hamamatsu University School of Medicine, 1-20-1 Handayama, Higashi-ku, Hamamatsu, Shizuoka, 431-3192, Japan
| | - Shumpei Sato
- Department of Cellular & Molecular Anatomy, Hamamatsu University School of Medicine, 1-20-1 Handayama, Higashi-ku, Hamamatsu, Shizuoka, 431-3192, Japan
| | - Ariful Islam
- Department of Cellular & Molecular Anatomy, Hamamatsu University School of Medicine, 1-20-1 Handayama, Higashi-ku, Hamamatsu, Shizuoka, 431-3192, Japan
| | - A S M Waliullah
- Department of Cellular & Molecular Anatomy, Hamamatsu University School of Medicine, 1-20-1 Handayama, Higashi-ku, Hamamatsu, Shizuoka, 431-3192, Japan
| | - Do Huu Chi
- Department of Cellular & Molecular Anatomy, Hamamatsu University School of Medicine, 1-20-1 Handayama, Higashi-ku, Hamamatsu, Shizuoka, 431-3192, Japan
| | - Yutaka Takahashi
- Department of Cellular & Molecular Anatomy, Hamamatsu University School of Medicine, 1-20-1 Handayama, Higashi-ku, Hamamatsu, Shizuoka, 431-3192, Japan
| | - Tomoaki Kahyo
- Department of Cellular & Molecular Anatomy, Hamamatsu University School of Medicine, 1-20-1 Handayama, Higashi-ku, Hamamatsu, Shizuoka, 431-3192, Japan
| | - Yasuhide Naito
- Graduate School for the Creation of New Photonics Industries, 1955-1 Kurematsu-cho, Nishi-ku, Hamamatsu, Shizuoka, 431-1202, Japan
| | - Masahiro Kotani
- Hamamatsu Photonics KK, 314-5 Shimokanzo, Iwata, Shizuoka, 438-0193, Japan
| | - Takayuki Ohmura
- Hamamatsu Photonics KK, 314-5 Shimokanzo, Iwata, Shizuoka, 438-0193, Japan
| | - Mitsutoshi Setou
- Department of Cellular & Molecular Anatomy, Hamamatsu University School of Medicine, 1-20-1 Handayama, Higashi-ku, Hamamatsu, Shizuoka, 431-3192, Japan
- International Mass Imaging Center, Hamamatsu University School of Medicine, 1-20-1 Handayama, Higashi-ku, Hamamatsu, Shizuoka, 431-3192, Japan
- Department of Systems Molecular Anatomy, Institute for Medical Photonics Research, Preeminent Medical Photonics Education & Research Center, 1-20-1 Handayama, Higashi-ku, Hamamatsu, Shizuoka, 431-3192, Japan
| |
Collapse
|
3
|
Wei J, Antzutkin ON, Filippov AV, Iuga D, Lam PY, Barrow MP, Dupree R, Brown SP, O'Connor PB. Amyloid Hydrogen Bonding Polymorphism Evaluated by (15)N{(17)O}REAPDOR Solid-State NMR and Ultra-High Resolution Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Biochemistry 2016; 55:2065-8. [PMID: 26983928 DOI: 10.1021/acs.biochem.5b01095] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
A combined approach, using Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) and solid-state NMR (Nuclear Magnetic Resonance), shows a high degree of polymorphism exhibited by Aβ species in forming hydrogen-bonded networks. Two Alzheimer's Aβ peptides, Ac-Aβ(16-22)-NH2 and Aβ(11-25), selectively labeled with (17)O and (15)N at specific amino acid residues were investigated. The total amount of peptides labeled with (17)O as measured by FTICR-MS enabled the interpretation of dephasing observed in (15)N{(17)O}REAPDOR solid-state NMR experiments. Specifically, about one-third of the Aβ peptides were found to be involved in the formation of a specific >C═(17)O···H-(15)N hydrogen bond with their neighbor peptide molecules, and we hypothesize that the rest of the molecules undergo ± n off-registry shifts in their hydrogen bonding networks.
Collapse
Affiliation(s)
| | - Oleg N Antzutkin
- Chemistry of Interfaces, Luleå University of Technology , SE-971 87, Luleå, Sweden
| | - Andrei V Filippov
- Chemistry of Interfaces, Luleå University of Technology , SE-971 87, Luleå, Sweden
| | | | | | | | | | | | | |
Collapse
|
4
|
Nagao T, Yukihira D, Fujimura Y, Saito K, Takahashi K, Miura D, Wariishi H. Power of isotopic fine structure for unambiguous determination of metabolite elemental compositions: in silico evaluation and metabolomic application. Anal Chim Acta 2014; 813:70-6. [PMID: 24528662 DOI: 10.1016/j.aca.2014.01.032] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2013] [Revised: 01/09/2014] [Accepted: 01/13/2014] [Indexed: 01/22/2023]
Abstract
In mass spectrometry (MS)-based metabolomics studies, reference-free identification of metabolites is still a challenging issue. Previously, we demonstrated that the elemental composition (EC) of metabolites could be unambiguously determined using isotopic fine structure, observed by ultrahigh resolution MS, which provided the relative isotopic abundance (RIA) of (13)C, (15)N, (18)O, and (34)S. Herein, we evaluated the efficacy of the RIA for determining ECs based on the MS peaks of 20,258 known metabolites. The metabolites were simulated with a ≤25% error in the isotopic peak area to investigate how the error size effect affected the rate of unambiguous determination of the ECs. The simulation indicated that, in combination with reported constraint rules, the RIA led to unambiguous determination of the ECs for more than 90% of the tested metabolites. It was noteworthy that, in positive ion mode, the process could distinguish alkali metal-adduct ions ([M+Na](+) and [M+K](+)). However, a significant degradation of the EC determination performance was observed when the method was applied to real metabolomic data (mouse liver extracts analyzed by infusion ESI), because of the influence of noise and bias on the RIA. To achieve ideal performance, as indicated in the simulation, we developed an additional method to compensate for bias on the measured ion intensities. The method improved the performance of the calculation, permitting determination of ECs for 72% of the observed peaks. The proposed method is considered a useful starting point for high-throughput identification of metabolites in metabolomic research.
Collapse
Affiliation(s)
- Tatsuhiko Nagao
- Graduate School of Bioresource and Bioenvironmental Sciences, Kyushu University, 6-10-1 Hakozaki, Higashi-ku, Fukuoka 812-8581, Japan
| | - Daichi Yukihira
- Graduate School of Bioresource and Bioenvironmental Sciences, Kyushu University, 6-10-1 Hakozaki, Higashi-ku, Fukuoka 812-8581, Japan
| | - Yoshinori Fujimura
- Innovation Center for Medical Redox Navigation, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Kazunori Saito
- Bruker Daltonics K.K., 3-9 Moriya-cho, Kanagawa-ku, Yokohama 221-0022, Japan
| | - Katsutoshi Takahashi
- Research Institute of Instrumentation Frontier, National Institute of Advanced Industrial Science and Technology, 2-42 Aomi, Koutou-ku, Tokyo 135-0064, Japan
| | - Daisuke Miura
- Innovation Center for Medical Redox Navigation, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan.
| | - Hiroyuki Wariishi
- Innovation Center for Medical Redox Navigation, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan; Faculty of Arts and Science, Kyushu University, 6-10-1 Hakozaki, Higashi-ku, Fukuoka 812-8581, Japan.
| |
Collapse
|
5
|
Nakata MT, Hart GW, Peterson BG. Peak coalescence, spontaneous loss of coherence, and quantification of the relative abundances of two species in the plasma regime: particle-in-cell modeling of Fourier transform ion cyclotron resonance mass spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2010; 21:1712-1719. [PMID: 20621505 DOI: 10.1016/j.jasms.2010.06.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2010] [Revised: 05/18/2010] [Accepted: 06/02/2010] [Indexed: 05/29/2023]
Abstract
Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) is often limited by space-charge effects. Previously, particle-in-cell (PIC) simulations have been used to understand these effects on FTICR-MS signals. However, none have extended fully into the space-charge dominated (plasma) regime. We use a two-dimensional (2-D) electrostatic PIC code, which facilitates work at very high number densities at modest computational cost to study FTICR-MS in the plasma regime. In our simulation, we have observed peak coalescence and the rapid loss of signal coherence, two common experimental problems. This demonstrates that a 2-D model can simulate these effects. The 2-D code can handle a larger numbers of particles and finer spatial resolution than can currently be addressed by 3-D models. The PIC method naturally takes into account image charge and space charge effects in trapped-ion mass spectrometry. We found we can quantify the relative abundances of two closely spaced (such as (7)Be(+) and (7)Li(+)) species in the plasma regime even when their peaks have coalesced. We find that the frequency of the coalesced peak shifts linearly according to the relative abundances of these species. Space charge also affects more widely spaced lines. Singly-ionized (7)BeH and (7)Li have two separate peaks in the plasma regime. Both the frequency and peak area vary nonlinearly with their relative abundances. Under some conditions, the signal exhibited a rapid loss of coherence. We found that this is due to a high order diocotron instability growing in the ion cloud.
Collapse
Affiliation(s)
- M Takeshi Nakata
- Department of Physics and Astronomy, Brigham Young University, Provo, Utah 84602, USA
| | | | | |
Collapse
|
6
|
Miura D, Tsuji Y, Takahashi K, Wariishi H, Saito K. A strategy for the determination of the elemental composition by fourier transform ion cyclotron resonance mass spectrometry based on isotopic peak ratios. Anal Chem 2010; 82:5887-91. [PMID: 20521766 DOI: 10.1021/ac902931x] [Citation(s) in RCA: 72] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
We propose a novel strategy for determining the elemental composition of organic compounds using the peak ratio of isotopic fine structure observed by high-magnetic field Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS). Using 3'-phosphoadenosine 5'-phosphosulfate and CTU guanamine as standard organic compounds, isotopic peaks derived from (15)N-, (34)S-, and (18)O-substituted forms were separated from (13)C-substituted species. Furthermore, these isotopic peaks were quantitatively detected and closely matched the natural abundance of each element. These data successfully led us to determine the one elemental composition in a standard independent manner. The approach should be particularly amenable to the metabolomics research field.
Collapse
Affiliation(s)
- Daisuke Miura
- Innovation Center for Medical Redox Navigation, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 12-8582, Japan
| | | | | | | | | |
Collapse
|
7
|
Boldin IA, Nikolaev EN. Theory of peak coalescence in Fourier transform ion cyclotron resonance mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2009; 23:3213-9. [PMID: 19725021 DOI: 10.1002/rcm.4231] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Peak coalescence, i.e. the merging of two close peaks in a Fourier transform ion cyclotron resonance (FTICR) mass spectrum at a high number of ions, plays an important role in various FTICR experiments. In order to describe the coalescence phenomenon we would like to propose a new theory of motion for ion clouds with close mass-to-charge ratios, driven by a uniform magnetic field and Coulomb interactions between the clouds. We describe the motion of the ion clouds in terms of their averaged drift motion in crossed magnetic and electric fields. The ion clouds are considered to be of constant size and their motion is studied in two dimensions. The theory deals with the first-order approximation of the equations of motion in relation to dm/m, where dm is the mass difference and m is the mass of a single ion. The analysis was done for an arbitrary inter-cloud interaction potential, which makes it possible to analyze finite-size ion clouds of any shape. The final analytical expression for the condition of the onset of coalescence is found for the case of uniformly charged spheres. An algorithm for finding this condition for an arbitrary interaction potential is proposed. The critical number of ions for the peak coalescence to take place is shown to depend quadratically on the magnetic field strength and to be proportional to the cyclotron radius and inversely proportional to the ion masses.
Collapse
Affiliation(s)
- Ivan A Boldin
- Institute for Energy Problems of Chemical Physics, Russian Academy of Sciences, Moscow, Russia
| | | |
Collapse
|
8
|
Tolmachev AV, Masselon CD, Anderson GA, Udseth HR, Smith RD. Frequency shifts due to the interference of resolved peaks in magnitude-mode Fourier-transform ion cyclotron resonance mass spectra. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2002; 13:387-401. [PMID: 11951977 DOI: 10.1016/s1044-0305(02)00349-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
We have obtained relationships for frequency shifts resulting from the interference of spectral components for the magnitude mode Fourier transform. The approximation of a weak perturbation of well resolved peaks has been used. Both the low- and high-pressure limits for Fourier-transform ion cyclotron resonance (FTICR) operation have been considered. We have found that the shifts can be either negative or positive, depending on the initial phase and/or the choice of the time-domain interval. The magnitude of shifts generally does not exceed the peak width. In the approximation of small perturbations the shifts produced by multiple peaks are additive. We have compared theoretical results with experimental shifts for isotopic clusters of multiply charged insulin. Up to 1 ppm frequency variations were experimentally observed for the insulin 5+ charge state, consistent with theoretical estimates. The peak interference is of particular significance in the case of bio-molecular mass spectra having a large number of peaks and covering a considerable dynamic range (i.e., relative abundance). We conclude that the common mass measurement procedure based on the location of the magnitude mode maxima of well resolved peaks can result in systematic mass measurement errors. The relationships obtained provide corrections for the frequency shifts and thus improve the mass measurement accuracy.
Collapse
Affiliation(s)
- Aleksey V Tolmachev
- Environmental Molecular Science Laboratory, Pacific Northwest National Laboratory, Richland, Washington 99352, USA
| | | | | | | | | |
Collapse
|
10
|
Badman ER, Patterson GE, Wells JM, Santini RE, Cooks RG. Differential non-destructive image current detection in a fourier transform quadrupole ion trap. JOURNAL OF MASS SPECTROMETRY : JMS 1999; 34:889-894. [PMID: 10423571 DOI: 10.1002/(sici)1096-9888(199908)34:8<889::aid-jms848>3.0.co;2-c] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Dual-detector differential non-destructive Fourier transform detection in a quadrupole ion trap is shown to improve signal intensity and reduce noise compared with spectra recorded using a single detector. A larger area detector in each end-cap electrode is machined to fit its hyperbolic shape and so minimize field imperfections on the z-axis. Argon, acetophenone and bromobenzene spectra were recorded to allow a comparison between single- and dual-detector (differential) modes of detection and to demonstrate the improvement achieved with differential detection. Copyright 1999 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- ER Badman
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907-1393, USA
| | | | | | | | | |
Collapse
|