1
|
Murakami K, Rancilio N, Foster L. Feasibility assessment of inspiration breath-hold motion management for tumor tracking during cone-beam computed tomography for setup and radiotherapy in Veterinary Medicine: A pilot study. Vet Radiol Ultrasound 2024; 65:672-678. [PMID: 39005141 DOI: 10.1111/vru.13412] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Revised: 05/08/2024] [Accepted: 07/01/2024] [Indexed: 07/16/2024] Open
Abstract
Radiotherapy (RT) for lung or liver tumors can be challenging due to respiration-induced organ motion (RIOM). There are some methodological solutions to minimize RIOM. We explored a new approach to evaluate the feasibility and reproducibility of RIOM during RT with five total client-owned tumor-bearing animals using a remote-triggered breath-hold ventilator under general anesthesia during image acquisition and RT. There was one stereotactic body radiotherapy, one conventionally fractionated definitive intent, and three conventionally fractionated palliative intent RT cases. Based on repeated cone beam CT, there were no treatment table shifts required prior to initiating beam on. No clinically significant complications such as hypotension occurred during anesthesia. This technique appeared to be safe in this group of patients and was easily clinically implemented and highly reproducible. More complete follow-up data and larger studies are needed to evaluate clinical outcomes with this breath-hold ventilator technique in veterinary RT.
Collapse
Affiliation(s)
- Keiko Murakami
- Department of Veterinary Clinical Sciences, Iowa State University College of Veterinary Medicine, Ames, Iowa, USA
| | - Nicholas Rancilio
- Department of Veterinary Clinical Sciences, Iowa State University College of Veterinary Medicine, Ames, Iowa, USA
| | - Lisa Foster
- Lloyd Veterinary Medical Center, Iowa State University College of Veterinary Medicine, Ames, Iowa, USA
| |
Collapse
|
2
|
Vanhaezebrouck IF, Scarpelli ML. Companion Animals as a Key to Success for Translating Radiation Therapy Research into the Clinic. Cancers (Basel) 2023; 15:3377. [PMID: 37444487 PMCID: PMC10341092 DOI: 10.3390/cancers15133377] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Revised: 06/23/2023] [Accepted: 06/23/2023] [Indexed: 07/15/2023] Open
Abstract
Many successful preclinical findings fail to be replicated during translation to human studies. This leads to significant resources being spent on large clinical trials, and in some cases, promising therapeutics not being pursued due to the high costs of clinical translation. These translational failures emphasize the need for improved preclinical models of human cancer so that there is a higher probability of successful clinical translation. Companion-animal cancers offer a potential solution. These cancers are more similar to human cancer than other preclinical models, with a natural evolution over time, genetic alterations, intact immune system, and a permanent adaptation to the microenvironment. These advantages have led pioneers in veterinary radiation oncology to aid human medicine by elucidating basic principles of radiation biology. More recently, the veterinary and human radiation oncology fields have increasingly collaborated to achieve advancements in education, radiotherapy techniques, and trial networks. This review describes these advancements, including significant prior research findings and the evolution of the veterinary radiation oncology discipline. It concludes by describing how companion-animal models can help shape the future of human radiotherapy. Taken as a whole, this review suggests companion-animal cancers may become widely used for preclinical radiotherapy research.
Collapse
Affiliation(s)
| | - Matthew L. Scarpelli
- School of Health Sciences, Purdue University, 550 W Stadium Ave, West Lafayette, IN 47907, USA;
| |
Collapse
|
3
|
Takemasa K, Kato T, Narita Y, Kato M, Yamazaki Y, Ouchi H, Oyama S, Yamaguchi H, Wada H, Murakami M. The impact of different setup methods on the dose distribution in proton therapy for hepatocellular carcinoma. J Appl Clin Med Phys 2021; 22:63-71. [PMID: 33595910 PMCID: PMC7984466 DOI: 10.1002/acm2.13178] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2020] [Revised: 12/08/2020] [Accepted: 01/06/2021] [Indexed: 11/10/2022] Open
Abstract
Purpose To investigate the impact of different setup methods, vertebral body matching (VM), diaphragm matching (DM), and marker matching (MM), on the dose distribution in proton therapy (PT) for hepatocellular carcinoma (HCC). Materials and Methods Thirty‐eight HCC lesions were studied retrospectively to assess changes in the dose distribution on two computed tomography (CT) scans. One was for treatment planning (1st‐CT), and the other was for dose confirmation acquired during the course of PT (2nd‐CT). The dose coverage of the clinical target volume (CTV‐D98) and normal liver volume that received 30 Gy relative biological effectiveness (RBE) (liver‐V30) were evaluated under each condition. Initial treatment planning on the 1st‐CT was defined as reference, and three dose distributions recalculated using VM, DM, and MM on the 2nd‐CT, were compared to it, respectively. In addition, the relationship between the CTV‐D98 of each method and the distance between the center of mass (COM) of the CTV and the right diaphragm top was evaluated. Results For CTV‐D98, significant differences were observed between the reference and VM and DM, respectively (P = 0.013, P = 0.015). There were also significant differences between MM and VM and DM, respectively (P = 0.018, P = 0.036). Regarding liver‐V30, there was no significant difference in any of the methods, and there were no discernable difference due to the different setup methods. In DM, only two out of 34 cases with a distance from right diaphragm top to COM of CTV of 90 mm or less that CTV‐D98 difference was 5% or more and CTV‐D98 was worse than VM were confirmed. Conclusion Although MM is obviously the most effective method, it is suggested that DM may be particularly effective in cases where the distance from right diaphragm top to COM of CTV of 90 mm or less.
Collapse
Affiliation(s)
- Kimihiro Takemasa
- Department of Radiation Physics and Technology, Southern Tohoku Proton Therapy Center, Fukushima, Japan
| | - Takahiro Kato
- Department of Radiation Physics and Technology, Southern Tohoku Proton Therapy Center, Fukushima, Japan.,Preparing Section for New Faculty of Medical Science, Fukushima Medical University, Fukushima, Japan
| | - Yuki Narita
- Department of Radiation Physics and Technology, Southern Tohoku Proton Therapy Center, Fukushima, Japan
| | - Masato Kato
- Department of Radiation Physics and Technology, Southern Tohoku Proton Therapy Center, Fukushima, Japan
| | - Yuhei Yamazaki
- Department of Radiation Physics and Technology, Southern Tohoku Proton Therapy Center, Fukushima, Japan
| | - Hisao Ouchi
- Department of Radiation Physics and Technology, Southern Tohoku Proton Therapy Center, Fukushima, Japan
| | - Sho Oyama
- Department of Radiation Physics and Technology, Southern Tohoku Proton Therapy Center, Fukushima, Japan
| | - Hisashi Yamaguchi
- Department of Radiation Oncology, Southern Tohoku Proton Therapy Center, Fukushima, Japan
| | - Hitoshi Wada
- Department of Radiation Oncology, Southern Tohoku Proton Therapy Center, Fukushima, Japan
| | - Masao Murakami
- Department of Radiation Oncology, Southern Tohoku Proton Therapy Center, Fukushima, Japan
| |
Collapse
|
4
|
Magestro L, Gieger T, Nolan M. Stereotactic body radiation therapy for heart-base tumors in six dogs. J Vet Cardiol 2018; 20:186-197. [DOI: 10.1016/j.jvc.2018.04.001] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2017] [Revised: 03/22/2018] [Accepted: 04/03/2018] [Indexed: 12/31/2022]
|
5
|
Zhao YT, Liu ZK, Wu QW, Dai JR, Zhang T, Jia AY, Jin J, Wang SL, Li YX, Wang WH. Observation of different tumor motion magnitude within liver and estimate of internal motion margins in postoperative patients with hepatocellular carcinoma. Cancer Manag Res 2017; 9:839-848. [PMID: 29276406 PMCID: PMC5731437 DOI: 10.2147/cmar.s147185] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
Aims To assess motion magnitude in different parts of the liver through surgical clips in postoperative patients with hepatocellular carcinoma and to examine the correlation between the clip and diaphragm motion. Methods Four-dimensional computed tomography images from 30 liver cancer patients under thermoplastic mask immobilization were selected for this study. Three to seven surgical clips were placed in the resection cavity of each patient. The liver volume on computed tomography image was divided into the right upper (RU), right middle (RM), right lower (RL), hilar, and left lobes. Agreement between the clip and diaphragm motion was assessed by calculating intraclass correlation coefficient, and Bland–Altman analysis (Diff). Furthermore, population-based and patient-specific margins for internal motion were evaluated. Results The clips located in the RU lobe showed the largest motion, (7.5±1.6) mm, which was significantly more than in the RM lobe (5.7±2.8 mm, p=0.019), RL lobe (4.8±3.3 mm, p=0.017), and hilar lobe (4.7±2.7 mm, p<0.001) in the cranial–caudal direction. The mean intraclass correlation coefficient values between the clip and diaphragm motion were 0.915, 0.735, 0.678, 0.670, and the mean Diff values between them were 0.1±0.8 mm, 2.3±1.4 mm, 3.1±2.0 mm, 2.4±1.5 mm, when clips were located in the RU lobe, RM lobe, RL lobe, and hilar lobe, respectively. The clip and diaphragm motions had high concordance when clips were located in the RU lobe. Internal margin can be reduced from 5 mm in the cranial–caudal direction based on patient population average and to 3 mm based on patient-specific margins. Conclusions The motion magnitude of clips varied significantly depending on their location within the liver. The diaphragm was a more appropriate surrogate for tumor located in the RU lobe than for other lobes.
Collapse
Affiliation(s)
- Yu-Ting Zhao
- Department of Radiation Oncology, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Zhi-Kai Liu
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Qiu-Wen Wu
- Department of Radiation Oncology, Duke University Medical Center, Durham, NC, USA
| | - Jian-Rong Dai
- Department of Radiation Oncology, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Tao Zhang
- Department of Radiation Oncology, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Angela Y Jia
- Department of Medicine, Weill Cornell Medicine, New York, NY, USA
| | - Jing Jin
- Department of Radiation Oncology, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Shu-Lian Wang
- Department of Radiation Oncology, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Ye-Xiong Li
- Department of Radiation Oncology, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Wei-Hu Wang
- Key laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Department of Radiation Oncology, Peking University Cancer Hospital and Institute, Beijing, China
| |
Collapse
|
6
|
Lesser TG, Schubert H, Güllmar D, Reichenbach JR, Wolfram F. One-lung flooding reduces the ipsilateral diaphragm motion during mechanical ventilation. Eur J Med Res 2016; 21:9. [PMID: 26957315 PMCID: PMC4784448 DOI: 10.1186/s40001-016-0205-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2016] [Accepted: 02/26/2016] [Indexed: 12/25/2022] Open
Abstract
BACKGROUND Diaphragm motion during spontaneous or mechanical respiration hinders image-guided percutaneous interventions of tumours in lung and upper abdomen. Motion-tracking methods can be applied but increase procedure complexity and procedure time. One-lung flooding (OLF) generates a suitable acoustic pathway to lung tumours and likely suppress diaphragm motion. The aim of this study was to quantify the effect of OLF on ipsilateral diaphragm motion during contralateral one-lung ventilation. METHODS To measure the diaphragm motion, M-mode ultrasonography of the right hemidiaphragm was performed during spontaneous breathing and mechanical ventilation, as well as after right-side lung flooding, in three pigs. Diaphragm motion was analysed using magnetic resonance images during left-side lung flooding and mechanical ventilation, in four pigs. RESULTS Double-lung ventilation increased the diaphragm movement in comparison with spontaneous breathing (17.8 ± 4.4 vs. 12.2 ± 3.4 mm, p = 0.014). Diaphragm movement on the flooded side during contralateral one-lung ventilation was significantly reduced compared to that during double-lung ventilation (3.9 ± 1.0 vs. 17.8 ± 4.4 mm, p = 0.041). By analysing the magnetic resonance images, the hemidiaphragm on the flooded side showed an average displacement of 4.2 mm, a maximum displacement of 15 mm close to the ventilated lung and no displacement at the lateral side. CONCLUSION OLF leads to a drastic reduction of diaphragm motion on the ipsilateral side which implies that targeting and motion compensation algorithms for interventions like high-intensity focused ultrasound ablation of intrapulmonary and hepatic lesions might not be required.
Collapse
Affiliation(s)
- Thomas Günther Lesser
- Department of Thoracic and Vascular Surgery, SRH Wald-Klinikum Gera, Teaching Hospital of Friedrich-Schiller University of Jena, Strasse des Friedens 122, 07548, Gera, Germany.
| | - Harald Schubert
- Institute of Animal Experimentation and Animal Welfare, Jena University Hospital, Friedrich-Schiller University, Jena, Germany.
| | - Daniel Güllmar
- Medical Physics Group, Institute of Diagnostic and Interventional Radiology, Jena University Hospital, Friedrich-Schiller University, Jena, Germany.
| | - Jürgen R Reichenbach
- Medical Physics Group, Institute of Diagnostic and Interventional Radiology, Jena University Hospital, Friedrich-Schiller University, Jena, Germany.
| | - Frank Wolfram
- Department of Thoracic and Vascular Surgery, SRH Wald-Klinikum Gera, Teaching Hospital of Friedrich-Schiller University of Jena, Strasse des Friedens 122, 07548, Gera, Germany.
| |
Collapse
|
7
|
Yang J, Cai J, Wang H, Chang Z, Czito BG, Bashir MR, Palta M, Yin FF. Is diaphragm motion a good surrogate for liver tumor motion? Int J Radiat Oncol Biol Phys 2014; 90:952-8. [PMID: 25223297 DOI: 10.1016/j.ijrobp.2014.07.028] [Citation(s) in RCA: 63] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2014] [Revised: 07/17/2014] [Accepted: 07/19/2014] [Indexed: 12/25/2022]
Abstract
PURPOSE To evaluate the relationship between liver tumor motion and diaphragm motion. METHODS AND MATERIALS Fourteen patients with hepatocellular carcinoma (10 of 14) or liver metastases (4 of 14) undergoing radiation therapy were included in this study. All patients underwent single-slice cine-magnetic resonance imaging simulations across the center of the tumor in 3 orthogonal planes. Tumor and diaphragm motion trajectories in the superior-inferior (SI), anterior-posterior (AP), and medial-lateral (ML) directions were obtained using an in-house-developed normalized cross-correlation-based tracking technique. Agreement between the tumor and diaphragm motion was assessed by calculating phase difference percentage, intraclass correlation coefficient, and Bland-Altman analysis (Diff). The distance between the tumor and tracked diaphragm area was analyzed to understand its impact on the correlation between the 2 motions. RESULTS Of all patients, the mean (±standard deviation) phase difference percentage values were 7.1% ± 1.1%, 4.5% ± 0.5%, and 17.5% ± 4.5% in the SI, AP, and ML directions, respectively. The mean intraclass correlation coefficient values were 0.98 ± 0.02, 0.97 ± 0.02, and 0.08 ± 0.06 in the SI, AP, and ML directions, respectively. The mean Diff values were 2.8 ± 1.4 mm, 2.4 ± 1.1 mm, and 2.2 ± 0.5 mm in the SI, AP, and ML directions, respectively. Tumor and diaphragm motions had high concordance when the distance between the tumor and tracked diaphragm area was small. CONCLUSIONS This study showed that liver tumor motion had good correlation with diaphragm motion in the SI and AP directions, indicating diaphragm motion in the SI and AP directions could potentially be used as a reliable surrogate for liver tumor motion.
Collapse
Affiliation(s)
- Juan Yang
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina; School of Information Science and Engineering, Shandong University, Jinan, Shandong, China
| | - Jing Cai
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina
| | - Hongjun Wang
- School of Information Science and Engineering, Shandong University, Jinan, Shandong, China
| | - Zheng Chang
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina
| | - Brian G Czito
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina
| | - Mustafa R Bashir
- Department of Radiology, Duke University Medical Center, Durham, North Carolina
| | - Manisha Palta
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina
| | - Fang-Fang Yin
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina.
| |
Collapse
|
8
|
Iyengar P, Timmerman RD. Stereotactic Ablative Radiotherapy for Lung Cancer. Lung Cancer 2014. [DOI: 10.1002/9781118468791.ch21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
9
|
Muller A, Petrusca L, Auboiroux V, Valette PJ, Salomir R, Cotton F. Management of Respiratory Motion in Extracorporeal High-Intensity Focused Ultrasound Treatment in Upper Abdominal Organs: Current Status and Perspectives. Cardiovasc Intervent Radiol 2013; 36:1464-1476. [DOI: 10.1007/s00270-013-0713-0] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/11/2012] [Accepted: 05/08/2013] [Indexed: 12/25/2022]
|
10
|
CT-guided Navigation of Percutaneous Hepatic and Renal Radiofrequency Ablation under High-frequency Jet Ventilation: Feasibility Study. J Vasc Interv Radiol 2011; 22:1275-8. [DOI: 10.1016/j.jvir.2011.04.013] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2010] [Revised: 04/22/2011] [Accepted: 04/29/2011] [Indexed: 12/31/2022] Open
|
11
|
Fritz P, Kraus HJ, Mühlnickel W, Sassmann V, Hering W, Strauch K. High-frequency jet ventilation for complete target immobilization and reduction of planning target volume in stereotactic high single-dose irradiation of stage I non-small cell lung cancer and lung metastases. Int J Radiat Oncol Biol Phys 2009; 78:136-42. [PMID: 19910142 DOI: 10.1016/j.ijrobp.2009.07.1678] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2008] [Revised: 05/26/2009] [Accepted: 07/06/2009] [Indexed: 12/26/2022]
Abstract
PURPOSE To demonstrate the feasibility of complete target immobilization by means of high-frequency jet ventilation (HFJV); and to show that the saving of planning target volume (PTV) on the stereotactic body radiation therapy (SBRT) under HFJV, compared with SBRT with respiratory motion, can be predicted with reliable accuracy by computed tomography (CT) scans at peak inspiration phase. METHODS AND MATERIALS A comparison regarding different methods for defining the PTV was carried out in 22 patients with tumors that clearly moved with respiration. A movement span of the gross tumor volume (GTV) was defined by fusing respiration-correlated CT scans. The PTV enclosed the GTV positions with a safety margin throughout the breathing cycle. To create a PTV from CT scans acquired under HFJV, the same margins were drawn around the immobilized target. In addition, peak inspiration phase CT images (PIP-CTs) were used to approximate a target immobilized by HFJV. RESULTS The resulting HFJV-PTVs were between 11.6% and 45.4% smaller than the baseline values calculated as respiration-correlated CT-PTVs (median volume reduction, 25.4%). Tentative planning by means of PIP-CT PTVs predicted that in 19 of 22 patients, use of HFJV would lead to a reduction in volume of >or=20%. Using this threshold yielded a positive predictive value of 0.89, as well as a sensitivity of 0.94 and a specificity of 0.5. CONCLUSIONS In all patients, SBRT under HFJV provided a reliable immobilization of the GTVs and achieved a reduction in PTVs, regardless of patient compliance. Tentative planning facilitated the selection of patients who could better undergo radiation in respiratory standstill, both with greater accuracy and lung protection.
Collapse
Affiliation(s)
- Peter Fritz
- Department of Radiotherapy, St Marien-Krankenhaus, Siegen, Germany.
| | | | | | | | | | | |
Collapse
|
12
|
Biro P, Spahn D, Pfammatter T. High-frequency jet ventilation for minimizing breathing-related liver motion during percutaneous radiofrequency ablation of multiple hepatic tumours. Br J Anaesth 2009; 102:650-3. [DOI: 10.1093/bja/aep051] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
|
13
|
Timmerman RD, Kavanagh BD, Cho LC, Papiez L, Xing L. Stereotactic body radiation therapy in multiple organ sites. J Clin Oncol 2007; 25:947-52. [PMID: 17350943 DOI: 10.1200/jco.2006.09.7469] [Citation(s) in RCA: 315] [Impact Index Per Article: 17.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
INTRODUCTION Stereotactic body radiation therapy (SBRT) uses advanced technology to deliver a potent ablative dose to deep-seated tumors in the lung, liver, spine, pancreas, kidney, and prostate. METHODS SBRT involves constructing very compact high-dose volumes in and about the tumor. Tumor position must be accurately assessed throughout treatment, especially for tumors that move with respiration. Sophisticated image guidance and related treatment delivery technologies have developed to account for such motion and efficiently deliver high daily dose. All this serves to allow the delivery of ablative dose fractionation to the target capable of both disrupting tumor mitosis and cellular function. RESULTS Prospective phase I dose-escalation trials have been carried out to reach potent tumoricidal dose levels capable of eradicating tumors with high likelihood. These studies indicate a clear dose-response relationship for tumor control with escalating dose of SBRT. Prospective phase II studies have been reported from several continents consistently showing very high levels of local tumor control. Although late toxicity requires further careful assessment, acute and subacute toxicities are generally acceptable. Patterns of toxicity, both clinical and radiographic, are distinct from those observed with conventionally fractionated radiotherapy as a result of the unique biologic response to ablative fractionation. CONCLUSION Prospective trials using SBRT have confirmed the efficacy of treatment in a variety of patient populations. Although mechanisms of ablative-dose injury remain elusive, ongoing prospective trials offer the hope of finding the ideal application for SBRT in the treatment arsenal.
Collapse
Affiliation(s)
- Robert D Timmerman
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390-9183, USA.
| | | | | | | | | |
Collapse
|
14
|
Keall PJ, Mageras GS, Balter JM, Emery RS, Forster KM, Jiang SB, Kapatoes JM, Low DA, Murphy MJ, Murray BR, Ramsey CR, Van Herk MB, Vedam SS, Wong JW, Yorke E. The management of respiratory motion in radiation oncology report of AAPM Task Group 76. Med Phys 2006; 33:3874-900. [PMID: 17089851 DOI: 10.1118/1.2349696] [Citation(s) in RCA: 1557] [Impact Index Per Article: 81.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
This document is the report of a task group of the AAPM and has been prepared primarily to advise medical physicists involved in the external-beam radiation therapy of patients with thoracic, abdominal, and pelvic tumors affected by respiratory motion. This report describes the magnitude of respiratory motion, discusses radiotherapy specific problems caused by respiratory motion, explains techniques that explicitly manage respiratory motion during radiotherapy and gives recommendations in the application of these techniques for patient care, including quality assurance (QA) guidelines for these devices and their use with conformal and intensity modulated radiotherapy. The technologies covered by this report are motion-encompassing methods, respiratory gated techniques, breath-hold techniques, forced shallow-breathing methods, and respiration-synchronized techniques. The main outcome of this report is a clinical process guide for managing respiratory motion. Included in this guide is the recommendation that tumor motion should be measured (when possible) for each patient for whom respiratory motion is a concern. If target motion is greater than 5 mm, a method of respiratory motion management is available, and if the patient can tolerate the procedure, respiratory motion management technology is appropriate. Respiratory motion management is also appropriate when the procedure will increase normal tissue sparing. Respiratory motion management involves further resources, education and the development of and adherence to QA procedures.
Collapse
|
15
|
Kavanagh BD, McGarry RC, Timmerman RD. Extracranial Radiosurgery (Stereotactic Body Radiation Therapy) for Oligometastases. Semin Radiat Oncol 2006; 16:77-84. [PMID: 16564443 DOI: 10.1016/j.semradonc.2005.12.003] [Citation(s) in RCA: 112] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Extracranial radiosurgery, also known as stereotactic body radiation therapy (SBRT), is an increasingly used method of treatment of limited cancer metastases located in a variety of organs/sites including the spine, lungs, liver, and other areas in the abdomen and pelvis. The techniques used to perform SBRT were initially modeled after intracranial radiosurgery, although considerable evolution in technique and conduct has occurred for extracranial applications. Unlike intracranial radiosurgery, SBRT requires characterization and accounting for inherent organ movement including breathing motion. Potent dose hypofractionation schedules have been used with SBRT such that the treatment is generally both ablative and convenient. Because the treatment is severely damaging to tissues within and about the target, the volume of adjacent normal tissue must be strictly minimized to avoid toxic late effects. Outcomes in various sites show very high rates of local control with toxicity mostly related to tubular tissues like the airways and bowels. With proper conduct though, SBRT can be an extremely effective treatment option for oligometastases.
Collapse
Affiliation(s)
- Brian D Kavanagh
- Department of Radiation Oncology, University of Colorado Comprehensive Cancer Center, Aurora, CO, USA
| | | | | |
Collapse
|