Iezzi R, Cotroneo AR, Filippone A, Di Fabio F, Quinto F, Colosimo C, Bonomo L. Multidetector CT in Abdominal Aortic Aneurysm Treated with Endovascular Repair: Are Unenhanced and Delayed Phase Enhanced Images Effective for Endoleak Detection?
Radiology 2006;
241:915-21. [PMID:
17032909 DOI:
10.1148/radiol.2413050959]
[Citation(s) in RCA: 78] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE
To retrospectively determine the sensitivity and specificity of unenhanced, delayed enhanced phase (DEP), and arterial enhanced phase (AEP) multi-detector row computed tomography (CT) for depicting endoleaks during follow-up of endovascular aneurysm repair.
MATERIALS AND METHODS
Fifty patients (two women, 48 men; mean age, 72 years) underwent follow-up multi-detector row CT 1, 6, and 12 months after endovascular aneurysm repair. Unenhanced CT was performed with 2.5-mm collimation; 1-mm collimation was used with AEP and DEP examinations. Two independent readers assessed the presence of endoleak in three reading sessions: AEP (session A), unenhanced and AEP (session B), and AEP and DEP (session C). At 6- and 12-month follow-up, a fourth set was included: 1-month unenhanced and AEP (session D). Sensitivity, specificity, and positive predictive value of each session were calculated. Triple-phase multi-detector row CT was the reference standard.
RESULTS
At 1 month, sensitivity, specificity, and positive predictive value, respectively, were 79%, 75%, and 55% for session A; 93%, 97%, and 93% for session B; and 93%, 78%, and 62% for session C. At 6 months, sensitivity, specificity, and positive predictive value, respectively, were 92%, 68%, and 48% for session A; 92%, 100%, and 100% for session B; and 100%, 84%, and 67% for session C. At 12 months, sensitivity, specificity, and positive predictive value, respectively, were 80%, 80%, and 50% for session A; 90%, 98%, and 90% for session B; and 100%, 80%, and 56% for session C. Sensitivity did not significantly differ (P > .05) among reading sessions A, B, and C, whereas specificity and positive predictive values in session B were significantly higher (P < .001). For 6- and 12-month follow-up, no significant differences (P > .05) were found between sessions D and B.
CONCLUSION
The combination of AEP and unenhanced imaging performed at 1-month follow-up offers improved specificity and positive predictive values compared with AEP alone. DEP imaging does not significantly increase sensitivity for detection of endoleaks, but it does depict low-flow endoleaks not seen at AEP.