1
|
Wang Z, Bian L, Mo C, Kukula M, Schug KA, Brotto M. Targeted quantification of lipid mediators in skeletal muscles using restricted access media-based trap-and-elute liquid chromatography-mass spectrometry. Anal Chim Acta 2017; 984:151-161. [PMID: 28843558 DOI: 10.1016/j.aca.2017.07.024] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2017] [Revised: 06/15/2017] [Accepted: 07/09/2017] [Indexed: 12/18/2022]
Abstract
Lipid mediators (LMs) are a class of bioactive metabolites of the essential polyunsaturated fatty acids (PUFA), which are involved in many physiological processes. Their quantification in biological samples is critical for understanding their functions in lifestyle and chronic diseases, such as diabetes, as well allergies, cancers, and in aging processes. We developed a rapid, and sensitive LC-MS/MS method to quantify the concentrations of 14 lipid mediators of interest in mouse skeletal muscle tissue without time-consuming liquid-liquid or solid-phase extractions. A restricted-access media (RAM) based trap was used prior to LC-MS as cleanup process to prevent the analytical column from clogging and deterioration. The system enabled automatic removal of residual proteins and other biological interferences presented in the tissue extracts; the target analytes were retained in the trap and then eluted to an analytical column for separation. Matrix evaluation tests demonstrated that the use of the combined RAM trap and chromatographic separation efficiently eliminated the biological or chemical matrix interferences typically encountered in bioanalytical analysis. Using 14 LM standards and 12 corresponding deuterated compounds as internal standards, the five-point calibration curves, established over the concentration range of 0.031-320 ng mL-1, demonstrated good linearity of r2 > 0.9903 (0.9903-0.9983). The lower detection limits obtained were 0.016, 0.031, 0.062, and 0.31 ng mL-1 (0.5, 1, 2, and 10 pg on column), respectively, depending on the specific compounds. Good accuracy (87.1-114.5%) and precision (<13.4%) of the method were observed for low, medium, and high concentration quality control samples. The method was applied to measure the amount of 14 target LMs in mouse skeletal muscle tissues. All 14 analytes in this study were successfully detected and quantified in the gastrocnemius muscle samples, which provided crucial information for both age and gender-related aspects of LMs signaling in skeletal muscles previously unknown. This method could be applied to advance the understanding of skeletal muscle pathophysiology to study the role of LMs in health and disease. Furthermore, we will expand the application of this methodology to humans and other tissues/matrices in the near future.
Collapse
Affiliation(s)
- Zhiying Wang
- College of Nursing and Health Innovation, The University of Texas at Arlington, 411 S. Nedderman Dr., Arlington, TX 76019, USA
| | - Liangqiao Bian
- Shimadzu Center for Advanced Analytical Chemistry, The University of Texas at Arlington, 700 Planetarium Place, Arlington, TX 76019, USA
| | - Chenglin Mo
- College of Nursing and Health Innovation, The University of Texas at Arlington, 411 S. Nedderman Dr., Arlington, TX 76019, USA
| | - Maciej Kukula
- Shimadzu Center for Advanced Analytical Chemistry, The University of Texas at Arlington, 700 Planetarium Place, Arlington, TX 76019, USA
| | - Kevin A Schug
- Department of Chemistry and Biochemistry, The University of Texas at Arlington, 700 Planetarium Place, Arlington, TX 76019, USA
| | - Marco Brotto
- College of Nursing and Health Innovation, The University of Texas at Arlington, 411 S. Nedderman Dr., Arlington, TX 76019, USA.
| |
Collapse
|
2
|
Cox S, Bailey J, White M, Gordon K, Souza M. Determination of Meloxicam in Egg Whites and Yolks Using Reverse Phase Chromatography. J Chromatogr Sci 2017; 55:610-616. [PMID: 28334796 DOI: 10.1093/chromsci/bmx014] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2016] [Accepted: 02/15/2017] [Indexed: 11/14/2022]
Abstract
A new method of analysis has been developed and validated for the determination of meloxicam in egg whites and yolks. Following a liquid extraction for the whites and a solid phase extraction for the yolks, samples were separated on an XBridge C18 column and quantified using ultraviolet detection at 360 nm. The mobile phase was a mixture of water with glacial acetic acid and acetonitrile, with a flow rate of 1 mL/min. The procedure produced a linear graph over the concentration range 5-1500 ng/mL with a lower limit of quantification of 5 ng/mL. Intra- and inter-assay variability was 10% or less for both the whites and yolks. The average recovery for whites was 96% and the average recovery in yolks was 97%.
Collapse
Affiliation(s)
- Sherry Cox
- Department of Biomedical and Diagnostic Sciences, College of Veterinary Medicine, University of Tennessee, 2407 River Drive, Knoxville, TN 37996, USA
| | - Joan Bailey
- Department of Biomedical and Diagnostic Sciences, College of Veterinary Medicine, University of Tennessee, 2407 River Drive, Knoxville, TN 37996, USA
| | - Molly White
- Department of Biomedical and Diagnostic Sciences, College of Veterinary Medicine, University of Tennessee, 2407 River Drive, Knoxville, TN 37996, USA
| | - Kristen Gordon
- Department of Biomedical and Diagnostic Sciences, College of Veterinary Medicine, University of Tennessee, 2407 River Drive, Knoxville, TN 37996, USA
| | - Marcy Souza
- Department of Biomedical and Diagnostic Sciences, College of Veterinary Medicine, University of Tennessee, 2407 River Drive, Knoxville, TN 37996, USA
| |
Collapse
|
3
|
Ndunda EN, Mizaikoff B. Molecularly imprinted polymers for the analysis and removal of polychlorinated aromatic compounds in the environment: a review. Analyst 2016; 141:3141-56. [DOI: 10.1039/c6an00293e] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Molecularly imprinted polymers selective to polychlorinated aromatic compounds for application in environmental studies.
Collapse
Affiliation(s)
- Elizabeth N. Ndunda
- Institute of Analytical and Bioanalytical Chemistry
- Ulm University
- 89081 Ulm
- Germany
| | - Boris Mizaikoff
- Institute of Analytical and Bioanalytical Chemistry
- Ulm University
- 89081 Ulm
- Germany
| |
Collapse
|
4
|
High-Performance Liquid Chromatography Determination of Meloxicam and Piroxicam with Ultraviolet Detection. ACTA ACUST UNITED AC 2014. [DOI: 10.1155/2014/521697] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
A simple accurate and sensitive high-performance liquid chromatographic method for the determination of meloxicam and piroxicam concentrations in small volume plasma samples has been developed. Following a liquid extraction using chloroform, samples were separated by reversed-phase high-performance liquid chromatography on an XBridge C18 column (4.6 × 250 mm) and quantified using ultraviolet detection at 360 nm. The mobile phase was a mixture of water with glacial acetic acid (pH 3.0) and acetonitrile (50 : 50), with a flow rate of 1.0 mL/min. The standard curve ranged from 5 to 10,000 ng/mL for meloxicam in bearded dragon (Pogona vitticeps) plasma and piroxicam in crane (Grus rubicunda) plasma. Intra- and interassay variability for meloxicam and piroxicam were less than 10% and the average recovery was greater than 90% for both drugs. This method was developed in bearded dragon and crane plasma and should be applicable to any species, making it useful for those investigators dealing with small sample volumes, particularly when conducting pharmacokinetics studies which require multiple sampling from the same animal.
Collapse
|
5
|
Yang SH, Fan H, Classon RJ, Schug KA. Restricted access media as a streamlined approach toward on-line sample preparation: Recent advancements and applications. J Sep Sci 2013; 36:2922-38. [DOI: 10.1002/jssc.201300595] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2013] [Revised: 06/16/2013] [Accepted: 06/21/2013] [Indexed: 01/22/2023]
Affiliation(s)
- Samuel H. Yang
- Department of Chemistry and Biochemistry; The University of Texas at Arlington; Arlington TX USA
| | - Hui Fan
- Department of Chemistry and Biochemistry; The University of Texas at Arlington; Arlington TX USA
| | | | - Kevin A. Schug
- Department of Chemistry and Biochemistry; The University of Texas at Arlington; Arlington TX USA
| |
Collapse
|
6
|
Hobl EL, Mader RM, Jilma B, Duhm B, Mustak M, Bröll H, Högger P, Erlacher L. A randomized, double-blind, parallel, single-site pilot trial to compare two different starting doses of methotrexate in methotrexate-naïve adult patients with rheumatoid arthritis. Clin Ther 2012; 34:1195-203. [PMID: 22516039 DOI: 10.1016/j.clinthera.2012.03.059] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/26/2012] [Indexed: 11/18/2022]
Abstract
BACKGROUND Methotrexate (MTX) is a cornerstone in the treatment of rheumatoid arthritis. Despite its widespread use, expert opinions differ about the optimal MTX starting dosage to achieve rapid onset of action while averting increased occurrence of adverse effects. Plasma concentrations have not been assessed in previous studies that monitored clinical efficacy. OBJECTIVE This study was performed to compare the pharmacokinetic parameters and clinical response of a standard (15 mg) and an accelerated (25 mg) dosing regimen, each administered orally once a week. METHODS This randomized, controlled, double-blind, parallel, single-site study included 19 MTX-naïve patients older than 18 years with rheumatoid arthritis. Patients participated for 16 weeks. Disease activity was assessed using the Disease Activity Score in 28 joints (DAS-28) as the primary outcome parameter. Plasma MTX concentrations were measured using HPLC at weeks 1, 5, 10, and 16. Tolerability was assessed via routine blood analysis (hematology and clinical chemistry) and a patient questionnaire to monitor adverse events. Reported or observed adverse events were recorded along with information about their severity and causal relationship to the study medication. RESULTS Nineteen white patients (13 women and 6 men; mean age, 56 years; and mean weight, 74 kg) participated. At study entry, mean (SD) DAS-28-4v (erythrocyte sedimentation rate) was 4.73 (1.02). Health Assessment Questionnaire scores were 1.45 (0.85); for C-reactive protein, 11.45 (10.04) mg/dL; for alkaline phosphatase, 73.58 (19.91) U/L; for aspartate aminotransferase, 23.32 (7.13) U/L; and for creatinine, 0.87 (0.22) mg/dL. Although pharmacokinetic parameters such as AUC and C(max) were significantly higher after the accelerated dosing regimen, clinical activity scores (DAS-28) and inflammation parameters (C-reactive protein) did not indicate a significant benefit of an accelerated starting regimen. Considering toxicity, no elevation in liver function enzymes and no decrease in renal function were observed using the accelerated dosing (statistical significance set at P ≤ 0.05). No serious adverse events were noted. All observed adverse events were classified as study related. Overall, adverse events were noted in 58% of patients. Comparison of the two doses revealed that 60% of patients receiving the standard dosing regimen and 56% of patients receiving the accelerated dosing regimen reported adverse events, the most frequent being gastrointestinal. These events were generally self-limiting. CONCLUSIONS Differences in clinical response between these two small selected patient groups who received an initial oral dose of either 15 or 25 mg MTX per week did not reach the level of statistical significance. The overall incidence of adverse effects, all classified as study related, was 58%, with 60% of patients receiving the standard dosage and 56% of patients receiving the accelerated dosing regimen reporting adverse effects. However, because of the small sample size, this study was not powered to detect differences in the incidence of adverse events between the two dosing groups. ClinicalTrials.gov identifier: NCT00695188.
Collapse
Affiliation(s)
- Eva-Luise Hobl
- Department of Clinical Pharmacology, Medical University of Vienna, Austria
| | | | | | | | | | | | | | | |
Collapse
|
7
|
Liquid chromatography-tandem mass spectrometry method for the determination of meloxicam and its metabolite 5-carboxymeloxicam in human plasma. Bioanalysis 2011; 1:63-70. [PMID: 21083189 DOI: 10.4155/bio.09.10] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND To develop and validate a rapid, sensitive and selective liquid chromatography-electrospray ionization mass spectrometric method for the determination of meloxicam and its metabolite 5-carboxymeloxicam in human plasma. RESULTS A liquid extraction method was chosen for sample clean-up. Meloxicam, 5-carboxymeloxicam and isoxicam (internal standard) were analyzed on an XBridge™ C18 column with 65% methanol in 10 mM ammonium formate (pH 3.0) and detected in selected reaction monitoring mode. The standard curves were linear over the concentration range 10-2500 ng/ml for meloxicam and 2-100 ng/ml for 5-carboxymeloxicam. Matrix effects were practically absent. CONCLUSIONS This method has been successfully applied to the pharmacokinetic study of meloxicam and 5-carboxymeloxicam after oral administration of meloxicam (15 mg) to 30 volunteers.
Collapse
|
8
|
Wa C, Mallik R, Hage DS. Development of immunoaffinity restricted access media for rapid extractions of low-mass analytes. Anal Chem 2008; 80:8751-62. [PMID: 18937423 DOI: 10.1021/ac801233t] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Restricted access media using antibodies as immobilized ligands were developed for the rapid and selective capture of small analytes by immunoextraction, giving rise to materials referred to as immunoaffinity restricted access media (IA-RAM). To make such a material, intact antibodies for the desired target were first immobilized onto porous silica, with antibodies at or near the outer surface of the support then being treated with papain (or a related agent) to release and remove their binding domains. The result was a support in which only antibodies deep within the pores remained intact and able to bind to the target. Items evaluated in the development of such media included the immobilization method used for the antibodies, the pore size of the support, and the amount of papain and time that were used for support treatment. A theoretical model was also developed to describe the extent of binding domain removal based on the measured polypeptide content of the IA-RAM support before and after treatment with papain. The final optimized conditions for making the IA-RAM supports were used to prepare columns that contained antifluorescein antibodies. Injections of fluorescein and fluorescein-labeled bovine serum albumin onto these IA-RAM columns gave selective and quantitative extraction of fluorescein in 1-2 s. This approach can be used with other antibodies and low-mass targets and should be valuable for such applications as the rapid separation of drugs from drug-protein complexes or the isolation of labeled/modified peptides from intact proteins that contain the same modification or label.
Collapse
Affiliation(s)
- Chunling Wa
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska 68588-0304, USA
| | | | | |
Collapse
|
9
|
Vignaduzzo SE, Castellano PM, Kaufman TS. Method development and validation for the simultaneous determination of meloxicam and pridinol mesylate using RP-HPLC and its application in drug formulations. J Pharm Biomed Anal 2008; 46:219-25. [DOI: 10.1016/j.jpba.2007.09.011] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2007] [Revised: 09/10/2007] [Accepted: 09/12/2007] [Indexed: 11/25/2022]
|
10
|
Natishan TK. Recent Developments of Achiral HPLC Methods in Pharmaceuticals Using Various Detection Modes. J LIQ CHROMATOGR R T 2007. [DOI: 10.1081/jlc-120030603] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Affiliation(s)
- Theresa K. Natishan
- a Merck & Co., Inc., Merck Research Laboratories , RY818‐C215, P.O. Box 2000, Rahway , New Jersey , 07065 , USA
| |
Collapse
|
11
|
Sadílek P, Šatínský D, Solich P. Using restricted-access materials and column switching in high-performance liquid chromatography for direct analysis of biologically-active compounds in complex matrices. Trends Analyt Chem 2007. [DOI: 10.1016/j.trac.2007.02.002] [Citation(s) in RCA: 103] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
12
|
Farhadi K, Karimpour A. Electrochemical Determination of Meloxicam in Pharmaceutical Preparation and Biological Fluids Using Oxidized Glassy Carbon Electrodes. Chem Pharm Bull (Tokyo) 2007; 55:638-42. [PMID: 17409562 DOI: 10.1248/cpb.55.638] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The adsorptive and electrochemical behaviors of meloxicam (MLC) was investigated on a glassy carbon electrode that was electrochemically treated by anodic oxidation at +1.8 V, following potential cycling in the potential range from -0.8 to 1.0 V vs. Ag/AgCl reference electrode. The resulting electrode showed a good activity to improve the electrochemical response of the drug. MLC was accumulated at an electrochemically activated glassy carbon electrode (phosphate buffer pH 6) in a certain time and then determined by linear sweep voltammetry. The oxidative peak currents showed a linear function in the concentration ranges of 0.02 to 10 microM using a 240 s preconcentration time. The preconcentration medium-exchange approach was utilized for the selective determination of the drug in spiked urine and plasma samples with satisfactory results. The recovery values of the proposed method obtained 105% (RSD 2.5%) and 100% (RSD 1.8%) for urine and plasma samples, respectively. Also, the proposed method has been successfully used for determination of MLC in tablets.
Collapse
Affiliation(s)
- Khalil Farhadi
- Department of Chemistry, Faculty of Science, Urmia University, Iran.
| | | |
Collapse
|
13
|
Voltammetric Determination of Meloxicam in Pharmaceutical Formulation and Human Serum at Glassy Carbon Electrode Modified by Cysteic Acid Formed by Electrochemical Oxidation of L-cysteine. SENSORS 2006. [DOI: 10.3390/s6091139] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
14
|
Taha EA, Salama NN, Fattah LESA. Spectrofluorimetric and Spectrophotometric Stability-Indicating Methods for Determination of Some Oxicams Using 7-Chloro-4-nitrobenz-2-oxa-1,3-diazole (NBD-Cl). Chem Pharm Bull (Tokyo) 2006; 54:653-8. [PMID: 16651760 DOI: 10.1248/cpb.54.653] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Two sensitive and selective spectrofluorimetric and spectrophotometric stability-indicating methods have been developed for the determination of some non-steroidal anti-inflammatory oxicam derivatives namely lornoxicam (Lx), tenoxicam (Tx) and meloxicam (Mx) after their complete alkaline hydrolysis. The methods are based on derivatization of alkaline hydrolytic products with 7-chloro-4-nitrobenz-2-oxa-1,3-diazole (NBD-Cl). The products showed an absorption maximum at 460 nm for the three studied drugs and fluorescence emission peak at 535 nm in methanol. The color was stable for at least 48 h. The optimum conditions of the reaction were investigated and it was found that the reaction proceeds quantitatively at pH 8, after heating in a boiling water bath for 30 min. The methods were found to be linear in the ranges of 1-10 microg ml(-1) for Lx and Tx and 0.5-4.0 microg ml(-1) for Mx for spectrophotometric method, while 0.05-1.0 microg ml(-1) for Lx and Tx and 0.025-0.4 microg ml(-1) for Mx for the spectrofluorimetric method. The validity of the methods was assessed according to USP guidelines. Statistical analysis of the results revealed high accuracy and good precision. The suggested procedures could be used for the determination of the above mentioned drugs in pure and dosage forms as well as in the presence of their degradation products.
Collapse
Affiliation(s)
- Elham Anwer Taha
- National Organization for Drug Control and Research, 6 Abou Hazem Street, Pyramids Avenue, Giza, Egypt.
| | | | | |
Collapse
|
15
|
Liu H, Zhang L, Hao Y, Wang Q, He P, Fang Y. Flow-injection chemiluminescence determination of meloxicam by oxidation with N-bromosuccinimide. Anal Chim Acta 2005. [DOI: 10.1016/j.aca.2005.02.078] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
16
|
Souverain S, Rudaz S, Veuthey JL. Restricted access materials and large particle supports for on-line sample preparation: an attractive approach for biological fluids analysis. J Chromatogr B Analyt Technol Biomed Life Sci 2004; 801:141-56. [PMID: 14751782 DOI: 10.1016/j.jchromb.2003.11.043] [Citation(s) in RCA: 213] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
An analytical process generally involves four main steps: (1) sample preparation; (2) analytical separation; (3) detection; and (4) data handling. In the bioanalytical field, sample preparation is often considered as the time-limiting step. Indeed, the extraction techniques commonly used for biological matrices such as liquid-liquid extraction (LLE) and solid-phase extraction (SPE) are achieved in the off-line mode. In order to perform a high throughput analysis, efforts have been engaged in developing a faster sample purification process. Among different strategies, the introduction of special extraction sorbents, such as the restricted access media (RAM) and large particle supports (LPS), allowing the direct and repetitive injection of complex biological matrices, represents a very attractive approach. Integrated in a liquid chromatography (LC) system, these extraction supports lead to the automation, simplification and speeding up of the sample preparation process. In this paper, RAM and LPS are reviewed and particular attention is given to commercially available supports. Applications of these extraction supports, are presented in single column and column-switching configurations, for the direct analysis of compounds in various biological fluids.
Collapse
Affiliation(s)
- S Souverain
- Laboratory of Pharmaceutical Analytical Chemistry, School of Pharmacy, University of Geneva, 20 Bd. d'Yvoy, 12114 Geneva, Switzerland
| | | | | |
Collapse
|