Elrod RW, Pelt CE, Mason JB, Volkmar AJ, Polkowksi GG, Coronado RA, Martin JR. Could Novel Radiographic Findings Help Identify Aseptic Tibial Loosening? J Arthroplasty 2023:S0883-5403(23)00051-7. [PMID: 36716899 DOI: 10.1016/j.arth.2023.01.031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Revised: 11/17/2022] [Accepted: 01/20/2023] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Aseptic loosening following total knee arthroplasty remains one of the leading causes of long-term failure. Radiographic identification of loose implants can be challenging with standard views. The purpose of this study was to compare the incidence of novel radiographic findings of anterior heterotopic bone formation and medial or lateral cyst formation in patients who have aseptic loosening to patients who have well-fixed implants. METHODS A retrospective radiographic review was performed on 48 patients' revised secondary to aseptic tibial loosening. This cohort was compared to two additional cohorts; 48 patients returning for routine postoperative follow-up (control 1), and 48 patients revised secondary to infection or instability who had well-fixed implants (control 2). RESULTS There were 41 of 48 (85%) patients who had implant loosening and were noted to have anterior heterotopic bone formation compared to 1 of 48 (2%) patients in control 1 and 3 of 48 (6%) patients in control 2 (P ≤ .0001). There were 43 of 48 (90%) patients who had implant loosening and had medial cyst formation compared to 3 of 48 (6%) patients in control 1 and 5 of 48 (10%) in control 2 (P ≤ .0001). There were 42 of 48 (88%) patients who had implant loosening and had lateral cyst formation compared to 2 of 48 (4%) patients in control 1 and 4 of 48 (8%) in control 2 (P ≤ .0001). CONCLUSION In this study, we describe novel radiographic findings of anterior heterotopic bone formation and cysts that develop in patients who have aseptic loosening following primary total knee arthroplasty. We believe that these radiographic features may lead to easier identification of aseptic loosening.
Collapse
Affiliation(s)
- Robert W Elrod
- Department of Orthopaedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Christopher E Pelt
- Department of Orthopaedic Surgery, University of Utah Health, Salt Lake City, Utah
| | - J Bohannan Mason
- Department of Orthopaedic Surgery, Carolinas Medical Center, Charlotte, North Carolina
| | - Alexander J Volkmar
- Department of Orthopaedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Gregory G Polkowksi
- Department of Orthopaedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Rogelio A Coronado
- Department of Orthopaedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - J Ryan Martin
- Department of Orthopaedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| |
Collapse
|
2
|
Mjöberg B. Hip prosthetic loosening and periprosthetic osteolysis: A commentary. World J Orthop 2022; 13:574-577. [PMID: 35949708 PMCID: PMC9244959 DOI: 10.5312/wjo.v13.i6.574] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Revised: 06/02/2022] [Accepted: 06/14/2022] [Indexed: 02/06/2023] Open
Abstract
Prosthetic loosening and periprosthetic osteolysis have been debated for decades, both in terms of the timing and nature of the triggering events. The hypothesis of wear-particle-induced loosening states that wear particles cause a foreign-body response leading to periprosthetic osteolysis and ultimately to late prosthetic loosening, i.e., that the osteolysis precedes the loosening. The theory of early loosening, on the other hand, postulates that the loosening is already initiated during or shortly after surgery, i.e., that the osteolysis is secondary to the loosening. This commentary focuses on the causal relationship between prosthetic loosening and periprosthetic osteolysis.
Collapse
Affiliation(s)
- Bengt Mjöberg
- Department of Orthopedics, Lund University, Lund SE-221 00, Sweden
| |
Collapse
|
3
|
Mjöberg B. Hip prosthetic loosening: A very personal review. World J Orthop 2021; 12:629-639. [PMID: 34631447 PMCID: PMC8472441 DOI: 10.5312/wjo.v12.i9.629] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 05/03/2021] [Accepted: 08/03/2021] [Indexed: 02/06/2023] Open
Abstract
Hip prosthetic loosening is often difficult to detect at an early stage, and there has been uncertainty for a long time as to when the loosening occurs and thus to the basic causes. By comparing different diagnostic methods, we found that loosening is best defined as prosthetic migration and measured by radiostereometric analysis. Convincing evidence indicates that poor interlock, poor bone quality, and resorption of a necrotic bone bed may initiate loosening during or shortly after surgery; this forms the basis of the theory of early loosening. Biomechanical factors do affect the subsequent progression of loosening, which may increase subclinically during a long period of time. Eventually, the loosening may be detected on standard radiographs and may be interpreted as late loosening but should to be interpreted as late detection of loosening. The theory of early loosening explains the rapid early migration, the development of periprosthetic osteolysis and granulomas, the causality between wear and loosening, and largely the epidemiology of clinical failure of hip prostheses. Aspects discussed are definition of loosening, the pattern of early migration, the choice of migration threshold, the current understanding of loosening, a less exothermic bone cement, cemented taper-slip stems, a new exciting computed tomography-based technique for simpler implant migration studies, and research suggestions.
Collapse
Affiliation(s)
- Bengt Mjöberg
- Department of Orthopedics, Lund University, Lund SE-221 00, Sweden
| |
Collapse
|
4
|
McArthur BA, Scully R, Patrick Ross F, Bostrom MPG, Falghren A. Mechanically Induced Periprosthetic Osteolysis: A Systematic Review. HSS J 2019; 15:286-296. [PMID: 31624485 PMCID: PMC6778158 DOI: 10.1007/s11420-018-9641-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/14/2017] [Accepted: 09/25/2018] [Indexed: 02/07/2023]
Abstract
BACKGROUND Peri-prosthetic bone loss can result from chemical, biological, and mechanical factors. Mechanical stimulation via fluid pressure and flow at the bone-implant interface may be a significant cause. Evidence supporting mechanically induced osteolysis continues to grow, but there is no synthesis of published clinical and basic science data. QUESTIONS/PURPOSES We sought to review the literature on two questions: (1) What published evidence supports the concept of mechanically induced osteolysis? (2) What is the proposed mechanism of mechanically induced osteolysis, and does it differ from that of particle-induced osteolysis? METHODS A systematic review was performed of the PubMed and Web of Science databases. Additional relevant articles were recommended by the senior authors based on their expert opinion. Abstracts were reviewed and the manuscripts pertaining to the study questions were read in full. Studies showing support of mechanically induced osteolysis were quantified and findings summarized. RESULTS We identified 49 articles of experimental design supporting the hypothesis that mechanical stimulation of peri-prosthetic bone from fluid pressure and flow can induce osteolysis. While the molecular mechanisms may overlap with those implicated in particle-induced osteolysis, mechanically induced osteolysis appears to be mediated by distinct and parallel pathways. CONCLUSIONS The role of mechanical stimuli is increasingly recognized in the pathogenesis of peri-prosthetic osteolysis. Current research aims to elucidate the molecular mechanisms to better target therapeutic interventions.
Collapse
Affiliation(s)
- Benjamin A. McArthur
- Department of Surgery and Perioperative Care, Dell Medical School at the University of Texas, Texas Orthopedics Sports and Rehabilitation Associates, 4215 Benner Road, Ste. 300, Kyle, TX 78640 USA
| | - Ryan Scully
- Department of Orthopedic Surgery, George Washington University, 2300 M Street, NW, Washington, DC, 20037 USA
| | - F. Patrick Ross
- Hospital for Special Surgery, 535 E. 70th Street, New York, NY 10021 USA
| | | | | |
Collapse
|
5
|
|
6
|
Moran MM, Wilson BM, Ross RD, Virdi AS, Sumner DR. Arthrotomy-based preclinical models of particle-induced osteolysis: A systematic review. J Orthop Res 2017; 35:2595-2605. [PMID: 28548682 PMCID: PMC5702596 DOI: 10.1002/jor.23619] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2016] [Accepted: 05/24/2017] [Indexed: 02/04/2023]
Abstract
We completed a systematic literature review of in vivo animal models that use arthrotomy-based methods to study particle-induced peri-implant osteolysis. The purpose of the review was to characterize the models developed to date, to determine the questions addressed, to assess scientific rigor and transparency, and to identify gaps in knowledge. We probed three literature databases (Medline, Embase, and Scopus) and found 77 manuscripts that fit the search parameters. In the most recent 10 years, researchers mainly used rat and mouse models, whereas in the previous 20 years, large animal, canine, and rabbit models were more common. The studies have demonstrated several pathophysiology pathways, including macrophage migration, particle phagocytosis, increased local production of cytokines and lysosomal enzymes, elevated bone resorption, and suppressed bone formation. The effect of variation in particle characteristics and concentration received limited attention with somewhat mixed findings. Particle contamination by endotoxin was shown to exacerbate peri-implant osteolysis. The possibility of early diagnosis was demonstrated through imaging and biomarker approaches. Several studies showed that both local and systemic delivery of bisphosphonates inhibits the development of particle-induced osteolysis. Other methods of inhibiting osteolysis include the use of anabolic agents and altering the implant design. Few studies examined non-surgical rescue of loosened implants, with conflicting results with alendronate. We found that the manuscripts often lacked the methodological detail now advocated by the ARRIVE guidelines, suggesting that improvement in reporting would be useful to maximize rigor and transparency. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2595-2605, 2017.
Collapse
Affiliation(s)
- Meghan M. Moran
- Department of Anatomy and Cell Biology, Rush University Medical Center
| | | | - Ryan D. Ross
- Department of Anatomy and Cell Biology, Rush University Medical Center
| | - Amarjit S. Virdi
- Department of Anatomy and Cell Biology, Rush University Medical Center
| | | |
Collapse
|
7
|
Amirhosseini M, Andersson G, Aspenberg P, Fahlgren A. Mechanical instability and titanium particles induce similar transcriptomic changes in a rat model for periprosthetic osteolysis and aseptic loosening. Bone Rep 2017; 7:17-25. [PMID: 28795083 PMCID: PMC5544474 DOI: 10.1016/j.bonr.2017.07.003] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/15/2016] [Revised: 07/24/2017] [Accepted: 07/26/2017] [Indexed: 01/30/2023] Open
Abstract
Wear debris particles released from prosthetic bearing surfaces and mechanical instability of implants are two main causes of periprosthetic osteolysis. While particle-induced loosening has been studied extensively, mechanisms through which mechanical factors lead to implant loosening have been less investigated. This study compares the transcriptional profiles associated with osteolysis in a rat model for aseptic loosening, induced by either mechanical instability or titanium particles. Rats were exposed to mechanical instability or titanium particles. After 15 min, 3, 48 or 120 h from start of the stimulation, gene expression changes in periprosthetic bone tissue was determined by microarray analysis. Microarray data were analyzed by PANTHER Gene List Analysis tool and Ingenuity Pathway Analysis (IPA). Both types of osteolytic stimulation led to gene regulation in comparison to unstimulated controls after 3, 48 or 120 h. However, when mechanical instability was compared to titanium particles, no gene showed a statistically significant difference (fold change ≥ ± 1.5 and adjusted p-value ≤ 0.05) at any time point. There was a remarkable similarity in numbers and functional classification of regulated genes. Pathway analysis showed several inflammatory pathways activated by both stimuli, including Acute Phase Response signaling, IL-6 signaling and Oncostatin M signaling. Quantitative PCR confirmed the changes in expression of key genes involved in osteolysis observed by global transcriptomics. Inflammatory mediators including interleukin (IL)-6, IL-1β, chemokine (C-C motif) ligand (CCL)2, prostaglandin-endoperoxide synthase (Ptgs)2 and leukemia inhibitory factor (LIF) showed strong upregulation, as assessed by both microarray and qPCR. By investigating genome-wide expression changes we show that, despite the different nature of mechanical implant instability and titanium particles, osteolysis seems to be induced through similar biological and signaling pathways in this rat model for aseptic loosening. Pathways associated to the innate inflammatory response appear to be a major driver for osteolysis. Our findings implicate early restriction of inflammation to be critical to prevent or mitigate osteolysis and aseptic loosening of orthopedic implants.
Collapse
Affiliation(s)
- Mehdi Amirhosseini
- Division of Cell Biology, Department of Clinical and Experimental Medicine, Faculty of Medicine and Health Sciences, Linköping University, Linköping, Sweden
- Corresponding author.
| | - Göran Andersson
- Division of Pathology, Department of Laboratory Medicine, Karolinska Institutet, Karolinska University Hospital, Huddinge, Sweden
| | - Per Aspenberg
- Orthopedics, Department of Clinical and Experimental Medicine, Faculty of Medicine and Health Sciences, Linköping University, Linköping, Sweden
| | - Anna Fahlgren
- Division of Cell Biology, Department of Clinical and Experimental Medicine, Faculty of Medicine and Health Sciences, Linköping University, Linköping, Sweden
| |
Collapse
|
8
|
Schunck A, Kronz A, Fischer C, Buchhorn GH. Release of zirconia nanoparticles at the metal stem-bone cement interface in implant loosening of total hip replacements. Acta Biomater 2016; 31:412-424. [PMID: 26612414 DOI: 10.1016/j.actbio.2015.11.044] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2015] [Revised: 11/16/2015] [Accepted: 11/19/2015] [Indexed: 11/28/2022]
Abstract
In a previous failure analysis performed on femoral components of cemented total hip replacements, we determined high volumes of abraded bone cement. Here, we describe the topography of the polished surface of polymethyl methacrylate (PMMA) bone cement containing zirconia radiopacifier, analyzed by scanning electron microscopy and vertical scanning interferometry. Zirconia spikes protruded about 300nm from the PMMA matrix, with pits of former crystal deposition measuring about 400nm in depth. We deduced that the characteristically mulberry-shaped agglomerates of zirconia crystals are ground and truncated into flat surfaces and finally torn out of the PMMA matrix. Additionally, evaluation of in vitro PMMA-on-PMMA articulation confirmed that crystal agglomerations of zirconia were exposed to grain pullout, fatigue, and abrasion. In great quantities, micron-sized PMMA wear and zirconia nanoparticles accumulate in the cement-bone interface and capsular tissues, thereby contributing to osteolysis. Dissemination of nanoparticles to distant lymph nodes and organs of storage has been reported. As sufficient information is lacking, foreign body reactions to accumulated nanosized zirconia in places of long-term storage should be investigated. STATEMENT OF SIGNIFICANCE The production of wear particles of PMMA bone cement in the interface to joint replacement devices, presents a local challenge. The presence of zirconia particles results in frustrated digestion attempts by macrophages, liberation of inflammatory mediators, and necrosis leading to aseptic inflammation and osteolyses. Attempts to minimize wear of articulating joints reduced the attention to the deterioration of cement cuffs. We therefore investigated polished surfaces of retrieved cuffs to demonstrate their morphology and to measure surface roughness. Industrially admixed agglomerates of the radiopacifier are abraded to micron and nano-meter sized particles. The dissemination of zirconia particles in the reticulo-endothelial system to storage organs is a possible burden. Research to replace the actual contrast media by non-particulate material deserves more attention.
Collapse
Affiliation(s)
- Antje Schunck
- University Hospital Göttingen, Department of Orthopedics/Biomaterials Research Laboratory, Robert-Koch-Str. 40, 37075 Göttingen, Germany.
| | - Andreas Kronz
- University of Göttingen, Department of Geochemistry, Goldschmidtstr. 1, 37077 Göttingen, Germany.
| | - Cornelius Fischer
- University of Bremen, MARUM/Department of Geosciences, Klagenfurter Str., 28359 Bremen, Germany.
| | - Gottfried Hans Buchhorn
- University Hospital Göttingen, Department of Orthopedics/Biomaterials Research Laboratory, Robert-Koch-Str. 40, 37075 Göttingen, Germany.
| |
Collapse
|
9
|
Kwak HS, Yoo JJ, Lee YK, Koo KH, Yoon KS, Kim HJ. The result of revision total hip arthroplasty in patients with metallosis following a catastrophic failure of a polyethylene liner. Clin Orthop Surg 2015; 7:46-53. [PMID: 25729518 PMCID: PMC4329532 DOI: 10.4055/cios.2015.7.1.46] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2014] [Accepted: 10/13/2014] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Wear cannot be completely prevented after total hip arthroplasty. If severe polyethylene (PE) liner wear develops, the so-called catastrophic failure occurs and metallosis develops. We postulated that longevity of the new implant may be affected after revision surgery for metallosis following a catastrophic failure of a PE liner due to the substantial amount of PE wear particles and infiltration of the metal particles in this catastrophic condition. METHODS Twenty-three hips of 23 patients were identified because they showed metallosis during revision total hip arthroplasties performed in Seoul National University Hospital between January 1996 and August 2004. They were followed for at least 6.5 years after the index revision total hip arthroplasty. The clinical and radiological results of revision total hip arthroplasties in these patients were evaluated. RESULTS The median Harris hip score increased from 60 points before revision total hip arthroplasties to 90 points at the final follow-up. Osteolysis was detected at an average of 9.3 years after revision total hip arthroplasties in 13 hips and acetabular cup loosening at average 9.8 years after revision total hip arthroplasties in 9 hips. With radiographic evidence of osteolysis and loosening as the end points, the 15-year survival rates were 28.2% and 56.0%, respectively. CONCLUSIONS The survival rate of revision total hip arthroplasty in patients with metallosis following a catastrophic failure of a PE liner was low.
Collapse
Affiliation(s)
- Hong Suk Kwak
- Department of Orthopedic Surgery, Joint and Spine Center, SMG-SNU Boramae Medical Center, Seoul National University College of Medicine, Seoul, Korea
| | - Jeong Joon Yoo
- Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul, Korea
| | - Young-Kyun Lee
- Department of Orthopedic Surgery, Seoul National University Bundang Hospital, Seongnam, Korea
| | - Kyung-Hoi Koo
- Department of Orthopedic Surgery, Seoul National University Bundang Hospital, Seongnam, Korea
| | - Kang Sup Yoon
- Department of Orthopedic Surgery, Joint and Spine Center, SMG-SNU Boramae Medical Center, Seoul National University College of Medicine, Seoul, Korea
| | - Hee Joong Kim
- Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul, Korea. ; Medical Research Center, Seoul National University, Seoul, Korea
| |
Collapse
|
10
|
Boeckstyns MEH, Toxvaerd A, Bansal M, Vadstrup LS. Wear particles and osteolysis in patients with total wrist arthroplasty. J Hand Surg Am 2014; 39:2396-404. [PMID: 25227599 DOI: 10.1016/j.jhsa.2014.07.046] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/14/2014] [Revised: 07/22/2014] [Accepted: 07/23/2014] [Indexed: 02/02/2023]
Abstract
PURPOSE To determine whether the amount of polyethylene debris in the interphase tissue between prosthesis and bone in patients with total wrist arthroplasty correlated with the degree of periprosthetic osteolysis (PPO); and to investigate the occurrence of metal particles in the periprosthetic tissue, the level of chrome and cobalt ions in the blood, and the possible role of infectious or rheumatoid activity in the development of PPO. METHODS Biopsies were taken from the implant-bone interphase in 13 consecutive patients with total wrist arthroplasty and with at least 3 years' follow-up. Serial annual radiographs were performed prospectively for the evaluation of PPO. We collected blood samples for white blood cell count, C-reactive protein, and metallic ion level. RESULTS A radiolucent zone of greater than 2 mm was observed juxta-articular to the radial component in 4 patients and at the carpal component in 3. The magnitude of the radiolucent zone tended to level out over time. We observed subsidence of the implant in 3 patients on the carpal side and in none on the radial side. The amount of polyethylene and metallic debris was generally small and did not correlate with the width of the radiolucent zone. The blood levels of chrome and cobalt ions were normal. There was no evidence of infectious or rheumatoid activity. CONCLUSIONS Polyethylene wear has been accepted as a major cause of osteolysis in total hip arthroplasty, and metallic debris has also been cited to be an underlying cause. However, our hypothesis that polyethylene debris correlated with the degree of PPO could not be confirmed. Also, metallic debris and infectious or rheumatoid activity did not correlate with PPO. TYPE OF STUDY/LEVEL OF EVIDENCE Prognostic I.
Collapse
Affiliation(s)
- Michel E H Boeckstyns
- Clinic of Hand Surgery, Gentofte Hospital, University of Copenhagen, Denmark, NY; Department of Pathology, Herlev Hospital, University of Copenhagen, Denmark, NY; Department of Pathology, Hospital for Special Surgery, New York, NY.
| | - Anders Toxvaerd
- Clinic of Hand Surgery, Gentofte Hospital, University of Copenhagen, Denmark, NY; Department of Pathology, Herlev Hospital, University of Copenhagen, Denmark, NY; Department of Pathology, Hospital for Special Surgery, New York, NY
| | - Manjula Bansal
- Clinic of Hand Surgery, Gentofte Hospital, University of Copenhagen, Denmark, NY; Department of Pathology, Herlev Hospital, University of Copenhagen, Denmark, NY; Department of Pathology, Hospital for Special Surgery, New York, NY
| | - Lars Soelberg Vadstrup
- Clinic of Hand Surgery, Gentofte Hospital, University of Copenhagen, Denmark, NY; Department of Pathology, Herlev Hospital, University of Copenhagen, Denmark, NY; Department of Pathology, Hospital for Special Surgery, New York, NY
| |
Collapse
|
11
|
Li N, Xu Z, Wooley PH, Zhang J, Yang SY. Therapeutic potentials of naringin on polymethylmethacrylate induced osteoclastogenesis and osteolysis, in vitro and in vivo assessments. DRUG DESIGN DEVELOPMENT AND THERAPY 2013; 8:1-11. [PMID: 24376342 PMCID: PMC3864877 DOI: 10.2147/dddt.s52714] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Wear debris associated periprosthetic osteolysis represents a major pathological process associated with the aseptic loosening of joint prostheses. Naringin is a major flavonoid identified in grapefruit. Studies have shown that naringin possesses many pharmacological properties including effects on bone metabolism. The current study evaluated the influence of naringin on wear debris induced osteoclastic bone resorption both in vitro and in vivo. The osteoclast precursor cell line RAW 264.7 was cultured and stimulated with polymethylmethacrylate (PMMA) particles followed by treatment with naringin at several doses. Tartrate resistant acid phosphatase (TRAP), calcium release, and gene expression profiles of TRAP, cathepsin K, and receptor activator of nuclear factor-kappa B were sequentially evaluated. PMMA challenged murine air pouch and the load bearing tibia titanium pin-implantation mouse models were used to evaluate the effects of naringin in controlling PMMA induced bone resorption. Histological analyses and biomechanical pullout tests were performed following the animal experimentation. The in vitro data clearly demonstrated the inhibitory effects of naringin in PMMA induced osteoclastogenesis. The naringin dose of 10 μg/mL exhibited the most significant influence on the suppression of TRAP activities. Naringin treatment also markedly decreased calcium release in the stimulated cell culture medium. The short-term air pouch mouse study revealed that local injection of naringin ameliorated the PMMA induced inflammatory tissue response and subsequent bone resorption. The long-term tibia pin-implantation mouse model study suggested that daily oral gavage of naringin at 300 mg/kg dosage for 30 days significantly alleviated the periprosthetic bone resorption. A significant increase of periprosthetic bone volume and regaining of the pin stability were found in naringin treated mice. Overall, this study suggests that naringin may serve as a potential therapeutic agent to treat wear debris associated osteolysis.
Collapse
Affiliation(s)
- Nianhu Li
- Department of Surgery, Orthopedics, University of Kansas School of Medicine, Wichita, KS, USA ; Department of Orthopedics, Affiliated Hospital to Shandong University of Traditional Chinese Medicine, Jinan, People's Republic of China
| | - Zhanwang Xu
- Department of Orthopedics, Affiliated Hospital to Shandong University of Traditional Chinese Medicine, Jinan, People's Republic of China
| | - Paul H Wooley
- Department of Surgery, Orthopedics, University of Kansas School of Medicine, Wichita, KS, USA ; Orthopaedic Research Institute, Via Christi Wichita Hospitals, Wichita, KS, USA
| | - Jianxin Zhang
- Department of Orthopedics, Affiliated Hospital to Shandong University of Traditional Chinese Medicine, Jinan, People's Republic of China
| | - Shang-You Yang
- Department of Surgery, Orthopedics, University of Kansas School of Medicine, Wichita, KS, USA ; Orthopaedic Research Institute, Via Christi Wichita Hospitals, Wichita, KS, USA
| |
Collapse
|
12
|
Rao AJ, Zwingenberger S, Valladares R, Li C, Lane Smith R, Goodman SB, Nich C. Direct subcutaneous injection of polyethylene particles over the murine calvaria results in dramatic osteolysis. INTERNATIONAL ORTHOPAEDICS 2013; 37:1393-8. [PMID: 23604215 DOI: 10.1007/s00264-013-1887-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2013] [Accepted: 03/26/2013] [Indexed: 12/23/2022]
Abstract
PURPOSE The murine calvarial model has been widely employed for the in vivo study of particle-induced osteolysis, the most frequent cause of aseptic loosening of total joint replacements. Classically, this model uses an open surgical technique in which polyethylene (PE) particles are directly spread over the calvarium for the induction of osteolysis. We evaluated a minimally invasive modification of the calvarial model by using a direct subcutaneous injection of PE particles. METHODS Polyethylene (PE) particles were injected subcutaneously over the calvaria of C57BL6J ten-week-old mice ("injection" group) or were implanted after surgical exposure of the calvaria ("open" group) (n = 5/group). For each group, five additional mice received no particles and served as controls. Particle-induced osteolysis was evaluated two weeks after the procedure using high-definition microCT imaging. RESULTS Polyethylene particle injection over the calvaria resulted in a 40% ± 1.8% decrease in the bone volume fraction (BVF), compared to controls. Using the "open surgical technique", the BVF decreased by 16% ± 3.8% as compared to controls (p < 0.0001). CONCLUSIONS Direct subcutaneous injection of PE particles over the murine calvaria produced more profound resorption of bone. Polyethylene particle implantation by injection is less invasive and reliably induces osteolysis to a greater degree than the open technique. This subcutaneous injection method will prove useful for repetitive injections of particles, and the assessment of potential local or systemic therapies.
Collapse
Affiliation(s)
- Allison J Rao
- Department of Orthopaedic Surgery, Orthopaedic Research Laboratories, Stanford University School of Medicine, Stanford, CA, USA
| | | | | | | | | | | | | |
Collapse
|
13
|
Alidousti H, Taylor M, Bressloff NW. Do capsular pressure and implant motion interact to cause high pressure in the periprosthetic bone in total hip replacement? J Biomech Eng 2012; 133:121001. [PMID: 22206418 DOI: 10.1115/1.4005455] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
When there is a debonding at the bone-implant interface, the difference in stiffness between the implant and the bone can result in micromotion, allowing existing gaps to open further or new gaps to be created during physiological loading. It has been suggested that periprosthetic fluid flow and high pressure may play an important role in osteolysis development in the proximity of these gaps. To explain this phenomenon, the concepts of "effective joint space" and "pumping stem" have been cited in many studies. However, there is no clear understanding of the factors causing, or contributing to, these mechanisms. It is likely that capsular pressure, gap dimensions, and micromotion of the gap during cyclic loading of an implant can play a defining role in inducing periprosthetic flow. In order to obtain a better understanding of the main influences on periprosthetic flows and the development of osteolysis, steady state and transient 2D computational fluid dynamic simulations were performed for the joint capsule of the lateral side of a stem-femur system, and a gap in communication with the capsule and the surrounding bone. It was shown that high capsular pressure may be the main driving force for high fluid pressure and flow in the bone surrounding the gap, while micromotion of only very long and narrow gaps can cause significant pressure and flow in the bone. At low capsular pressure, micromotion induced large flows in the gap region; however, the flow in the bone tissue was almost unaffected. The results also revealed the existence of high velocity spikes in the bone region at the bottom of the gap. These velocity spikes can exert excessive fluid shear stress on the bone cells and disturb the local biological balance of the surrounding interstitial fluid which can result in osteolysis development. High capsular pressure was observed to be the main cause of these velocity spikes whereas, at low capsular pressure, gap micromotion of only very long and narrow gaps generated significant velocity spikes in the bone at the bottom of the gaps.
Collapse
Affiliation(s)
- Hamidreza Alidousti
- School of Engineering Sciences, University of Southampton, Highfield, Southampton, UK
| | | | | |
Collapse
|
14
|
Johansson L, Edlund U, Fahlgren A, Aspenberg P. Fluid-induced osteolysis: modelling and experiments. Comput Methods Biomech Biomed Engin 2011; 14:305-18. [PMID: 21390935 DOI: 10.1080/10255842.2010.484808] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
A model to calculate bone resorption driven by fluid flow at the bone-soft tissue interface is developed and used as a basis for computer calculations, which are compared to experiments where bone is subjected to fluid flow in a rat model. Previous models for bone remodelling calculations have been based on the state of stress, strain or energy density of the bone tissue as the stimulus for remodelling. We believe that there is experimental support for an additional pathway where an increase in the amount of the cells directly involved in bone removal, the osteoclasts, is caused by fluid pressure, flow velocity or other parameters related to fluid flow at the bone-soft tissue interface, resulting in bone resorption.
Collapse
Affiliation(s)
- Lars Johansson
- Department of Management and Engineering, Linköping University, Linköping, Sweden.
| | | | | | | |
Collapse
|
15
|
Maoqiang L, Zhenan Z, Fengxiang L, Gang W, Yuanqing M, Ming L, Xin Z, Tingting T. Enhancement of osteoblast differentiation that is inhibited by titanium particles through inactivation of NFATc1 by VIVIT peptide. J Biomed Mater Res A 2011; 95:727-34. [PMID: 20725976 DOI: 10.1002/jbm.a.32891] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Bone formation, which is inhibited by particulate wear debris, is a pathological factor that contributes to periprosthetic osteolysis. Although the nuclear factor of activated T cells c1 (NFATc1) is known to be involved in osteoblast differentiation, and its effect on osteoblasts in response to wear particles remains unclear. In this study, we investigated the role of NFATc1 in the regulation of osteoblastic differentiation of rat calvaria (RC) cells (a cell-culture model comprising many osteoprogenitors) that were challenged with titanium (Ti) particles. The results showed that the Ti particles inhibited osteoblastic differentiation and mineralization of RC cells. NFATc1 plays a critical role in the Ti-particle inhibition process of the osteoblastic differentiation in RC cells. Inactivation of NFATc1 by the 11R-VIVIT peptide potently enhanced osteoblast differentiation and mineralization inhibition by the Ti particles. The 11R-VIVIT peptide does not have a toxic effect on the RC cells. On the basis of these data, we conclude that inactivation of NFATc1 by the 11R-VIVIT peptide may provide a promising therapeutic target for the treatment of periprosthetic osteolysis by increasing bone formation.
Collapse
Affiliation(s)
- Li Maoqiang
- Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, 639 Zhi Zao Ju Road, Shanghai, China
| | | | | | | | | | | | | | | |
Collapse
|
16
|
Yun HH, Shon WY, Hong SJ, Yoon JR, Yang JH. Relationship between the pelvic osteolytic volume on computed tomography and clinical outcome in patients with cementless acetabular components. INTERNATIONAL ORTHOPAEDICS 2010; 35:1453-9. [PMID: 20927513 DOI: 10.1007/s00264-010-1132-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2010] [Revised: 09/22/2010] [Accepted: 09/23/2010] [Indexed: 11/25/2022]
Abstract
The purpose of this study was to evaluate the relationship between the pelvic osteolytic volume on computed tomography (CT) and clinical outcome in patients with cementless acetabular components. We reviewed 87 patients (104 hips) who met the following inclusion criteria: (1) there was evidence of pelvic osteolysis on CT at a minium of five years postoperatively, (2) all cups and stems were radiographically stable at the time of CT, (3) the follow-up period after CT was a minimum of two years clinically. The mean pelvic osteolytic volume was 2.3 ± 6.9 cm(3). The mean Harris hip score (HHS) at CT was 92.3 ± 7.9 points. Inversely moderate correlation (r = -0.569, P < 0.05) was found between the HHS at CT and pelvic osteolytic volume. In ten cases of hips with acetabular revisions, the mean pelvic osteolytic volume was 16.3 ± 26.9 cm(3). The mean HHS at CT and HHS at reoperation was 87.6 ± 9.2 points and 73.4 ± 8.8 points, respectively, with significant difference (P < 0.05). The area under curve (ROC) analysis showed that the optimal cutoff value of the osteolytic volume was 4.8 cm(3) with 100% each for sensitivity and specificity. We conclude that the amount of pelvic osteolytic volume on CT may be used to guide treatment decision-making in patients with well-fixed cementless acetabular components who show evidence of pelvic osteolysis.
Collapse
Affiliation(s)
- Ho Hyun Yun
- Department of Orthopaedics, Seoul Veterans Hospital, Seoul, South Korea
| | | | | | | | | |
Collapse
|
17
|
Johansson L, Edlund U, Fahlgren A, Aspenberg P. Bone resorption induced by fluid flow. J Biomech Eng 2009; 131:094505. [PMID: 19725702 DOI: 10.1115/1.3194756] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
A model where bone resorption is driven by stimulus from fluid flow is developed and used as a basis for computer simulations, which are compared with experiments. Models for bone remodeling are usually based on the state of stress, strain, or energy density of the bone tissue as the stimulus for remodeling. We believe that there is experimental support for an additional pathway, where an increase in the amount of osteoclasts, and thus osteolysis, is caused by the time history of fluid flow velocity, fluid pressure, or other parameters related to fluid flow at the bone/soft tissue interface of the porosities in the bone.
Collapse
Affiliation(s)
- Lars Johansson
- Department of Management and Engineering, Linkoping University, Linkoping, Sweden.
| | | | | | | |
Collapse
|
18
|
Khayyeri H, Checa S, Tägil M, Prendergast PJ. Corroboration of mechanobiological simulations of tissue differentiation in an in vivo bone chamber using a lattice-modeling approach. J Orthop Res 2009; 27:1659-66. [PMID: 19514073 DOI: 10.1002/jor.20926] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
It is well established that the mechanical environment modulates tissue differentiation, and a number of mechanoregulatory theories for describing the process have been proposed. In this study, simulations of an in vivo bone chamber experiment were performed that allowed direct comparison with experimental data. A mechanoregulation theory for mesenchymal stem cell differentiation based on a combination of fluid flow and shear strain (computed using finite element analysis) was implemented to predict tissue differentiation inside mechanically controlled bone chambers inserted into rat tibae. To simulate cell activity, a lattice approach with stochastic cell migration, proliferation, and selected differentiation was adopted; because of its stochastic nature, each run of the simulation gave a somewhat different result. Simulations predicted the load-dependency of the tissue differentiation inside the chamber and a qualitative agreement with histological data; however, the full variability found between specimens in the experiment could not be predicted by the mechanoregulation algorithm. This result raises the question whether tissue differentiation predictions can be linked to genetic variability in animal populations.
Collapse
Affiliation(s)
- Hanifeh Khayyeri
- Trinity Centre for Bioengineering, School of Engineering, Trinity College Dublin, Ireland
| | | | | | | |
Collapse
|
19
|
The Boston Keratoprosthesis: comparing corneal epithelial cell compatibility with titanium and PMMA. Cornea 2009; 28:808-11. [PMID: 19574903 DOI: 10.1097/ico.0b013e31819670ac] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
PURPOSE To determine in vitro whether titanium is superior in corneal cell compatibility to standard polymethyl-methacrylate (PMMA) for the Boston Keratoprosthesis (KPro). METHODS Human corneal-limbal epithelial (HCLE) cells were cultured 24, 48, 72, 96, 120, 144, or 168 hours in culture plates alone (controls) or with PMMA or titanium discs. Experiments were performed in triplicate and repeated (final n = 6). To determine if a soluble, toxic factor is emitted from materials, concurrent experiments at 48 and 144 hours were performed with discs placed in Transwell Supports, with HCLE cells plated beneath. As an additional test for soluble factors, cells were incubated 24 hours with disc-conditioned media, and number of viable cells per well was quantified at each timepoint by proliferation assay. To determine if delayed cell proliferation was attributable to cell death, HCLE cell death was measured under all conditions and quantified at each timepoint by cytotoxicity assay. The effects of material on HCLE cell proliferation over time was determined by repeated measures ANOVA. P < 0.05 was statistically significant. RESULTS HCLE cell proliferation was greater in wells with titanium discs compared to PMMA. Differences between the test discs and control non-disc cocultures were statistically significant over time for both cell proliferation (P = 0.001) and death (P = 0.0025). No significant difference was found using Transwells (P = 0.9836) or disc-conditioned media (P = 0.36). CONCLUSION This in vitro HCLE cell model demonstrates significantly increased cell proliferation and decreased cell death with cell/titanium contact compared to cell/PMMA contact. Moreover, differences are unlikely attributable to a soluble factor. Prospective in vivo analysis of the two KPro biomaterials is indicated.
Collapse
|
20
|
Bylski D, Wedemeyer C, Xu J, Sterner T, Löer F, von Knoch M. Alumina ceramic particles, in comparison with titanium particles, hardly affect the expression of RANK-, TNF-alpha-, and OPG-mRNA in the THP-1 human monocytic cell line. J Biomed Mater Res A 2009; 89:707-16. [PMID: 18449944 DOI: 10.1002/jbm.a.31956] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Particle-induced osteolysis is the most frequent cause of aseptic loosening after total joint replacement. We performed a study to illuminate the effect of ceramic particles with different diameters and concentrations on the mRNA expression of certain key regulators in particle-induced aseptic osteolysis (RANK, RANKL, OPG, and TNF-alpha) in THP-1 macrophage-like cells. Titanium particles were used as a positive control. RNA was analyzed by quantitative RTPCR. Our results demonstrate that alumina ceramic particles, regardless of particle size, caused only slight upregulations of RANK, TNF-alpha, and OPG mRNA, whose levels were significantly lower in comparison with those of titanium particles (p < 0.05). The continuous increasing tendency to time and particle-dependent mRNA expression of all the parameters stimulated by titanium particles was not found after stimulation with ceramic materials. Even after the concentration of ceramic particles was increased, only a mild upregulation of mRNA expression was found. Furthermore, we observed that the bioinert properties of ceramic particles did not change much in diameters ranging from 0.5 to 1.5 microm. At most of the measuring time points, there was no significant difference between the reactions of the large and small particles in this range. Our results support the theory about the relative bioinert properties of alumina ceramic particles.
Collapse
Affiliation(s)
- David Bylski
- Department of Orthopaedics, University of Duisburg-Essen, Germany
| | | | | | | | | | | |
Collapse
|
21
|
Bartlett GE, Gill HS, Murray DW, Beard DJ. In vitro influence of stem surface finish and mantle conformity on pressure generation in cemented hip arthroplasty. Acta Orthop 2009; 80:139-43. [PMID: 19404792 PMCID: PMC2823161 DOI: 10.3109/17453670902947382] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Under physiological loads, debonded cemented femoral stems have been shown to move within their cement mantle and generate a fluid pump that may facilitate peri-prosthetic osteolysis by pressurizing fluid and circulating wear debris. The long-term physiological loading of rough and polished tapered stems in vitro has shown differences in performance, with greater interface pressures generated by the rough stems. In this study we investigated the individual effects of stem surface finish, degree of mantle wear, and mode of loading on the stem pump mechanism. METHOD Rough and polished stems were loaded under different regimes in artificially worn cement mantles that permitted either 2 or 5 degrees of rotational stem movement, and the interface pressures were compared. RESULTS The pressures generated by the rough and polished stems were similar in either type of mantle. The pattern of pressure generation in the 2-degree mantles was similar to the pressures generated by rough stems after long-term loading, but the high posterior wall pressures fell and the tip pressures increased in the 5-degree mantles. The torsional loads were principal drivers of pressure generation in all areas of the interface other than the implant tip, where axial loading predominated. INTERPRETATION Femoral stems with rotational instability under cyclic torsional loads generate elevated interface fluid pressures and flows independently of stem surface finish. The rough surface finish is only important in creating this instability in tapered stems.
Collapse
Affiliation(s)
- Gavin E Bartlett
- OOEC Nuffield Department of Orthopaedic Surgery, University of OxfordOxfordUK
| | - Harinderjit S Gill
- OOEC Nuffield Department of Orthopaedic Surgery, University of OxfordOxfordUK
| | - David W Murray
- OOEC Nuffield Department of Orthopaedic Surgery, University of OxfordOxfordUK
| | - David J Beard
- OOEC Nuffield Department of Orthopaedic Surgery, University of OxfordOxfordUK
| |
Collapse
|
22
|
Hoenders CSM, Harmsen MC, van Luyn MJA. The local inflammatory environment and microorganisms in “aseptic” loosening of hip prostheses. J Biomed Mater Res B Appl Biomater 2008; 86:291-301. [DOI: 10.1002/jbm.b.30992] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
23
|
What experimental approaches (eg, in vivo, in vitro, tissue retrieval) are effective in investigating the biologic effects of particles? J Am Acad Orthop Surg 2008; 16 Suppl 1:S63-7. [PMID: 18612016 PMCID: PMC2735389 DOI: 10.5435/00124635-200800001-00013] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Understanding the complex cellular and tissue mechanisms and interactions resulting in periprosthetic osteolysis requires a number of experimental approaches, each of which has its own set of advantages and limitations. In vitro models allow for the isolation of individual cell populations and have furthered our understanding of particle-cell interactions; however, they are limited because they do not mimic the complex tissue environment in which multiple cell interactions occur. In vivo animal models investigate the tissue interactions associated with periprosthetic osteolysis, but the choice of species and whether the implant system is subjected to mechanical load or to unloaded conditions are critical in assessing whether these models can be extrapolated to the clinical condition. Rigid analysis of retrieved tissue from clinical cases of osteolysis offers a different approach to studying the biologic process of osteolysis, but it is limited in that the tissue analyzed represents the end-stage of this process and, thus, may not reflect this process adequately.
Collapse
|
24
|
Abstract
An overwhelming consensus exists that wear particles are the primary driving force in aseptic loosening of orthopaedic implants. Nonetheless, considerable evidence has emerged demonstrating that various other factors can modulate the biologic activity of orthopaedic wear particles. Two of the most studied modulating factors are bacterial endotoxins and implant motion.
Collapse
|
25
|
Hilborn J, Bjursten LM. A new and evolving paradigm for biocompatibility. J Tissue Eng Regen Med 2007; 1:110-9. [DOI: 10.1002/term.4] [Citation(s) in RCA: 70] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
26
|
Abstract
Osteolysis remains a common mode of total hip arthroplasty failure. In vitro and animal models have been used to determine the pathophysiology of osteolysis by carefully dissecting the biochemical pathways leading to particulate wear debris and periprosthetic bone loss. Numerous cytokines and inflammatory mediators, including TNF-alpha and IL-1, are critical participants in this cascade and may represent prime targets for pharmacologic intervention. Osteoclasts, the end effector cells involved in the osteolytic process, also represent potential targets. Cell surface receptors on osteoclast precursors, such as receptor activator of NF-kappaB (RANK) (on osteoclasts) and RANK-ligand (RANKL) (on stromal cells), provide opportunities to arrest osteoclast maturation. Enhancing the naturally occurring osteoprotegerin is another recent attempt at modulating osteoclast behavior and a possible target for pharmacologic therapies. Other nonoperative strategies include intercepting tumor necrosis factor-alpha activity, interfering with the RANK-RANKL interaction necessary for osteoclast development and maturation, bisphosphonate therapy, and using viral vectors to deliver genes. Although each of these approaches has potential benefits, there are substantial challenges to effective implementation. Until there is convincing evidence of efficacy in human clinical trials, we recommend vigilant screening and appropriate surgery with component loosening or substantial likelihood of loosening, periprosthetic fracture, or major bone loss.
Collapse
Affiliation(s)
- Carl T Talmo
- Department of Orthopedic Surgery, Massachusetts General Hospital, Harvard Medical School, 55 Fruit St, YAW 3B, Boston, MA 02114, USA
| | | | | |
Collapse
|
27
|
Abstract
The aseptic prosthetic loosening of hip and knee prosthesis is the most important cause of implant insufficiency. Bone loss as a result of the biological effect of wear particles is the main cause of such loosening. Wear particles develop their biological activity along different cellular pathways, above all via macrophages, foreign body giant cells as well as fibroblasts of the periprosthetic membrane. These cells induce particle-dependent bone resorption by means of proinflammatory cytokines, such as IL-1beta, TNF-alpha, IL-6 and PGE2. These factors induce the activation of osteoclasts as well as the suppression of osteoblasts. Neutrophil granulocytes and lymphocytes do not play an important role in the process of aseptic loosening. The different wear particles, such as ultra-high molecular weight polyethylene, metal particles, ceramic particles and polymethylmethacrylate can be morphologically recognized very easily. From the clinical point of view, the differentiation between acute or chronic implant infection and particle induced prosthetic loosening is very important, with the histomorphological differential diagnosis between septic and aseptic loosening and their combination being the key clinicopathological factor.
Collapse
Affiliation(s)
- M Otto
- Institut für Pathologie Trier und Referenzzentrum für Implantatpathologie/Biomaterialien.
| | | | | | | |
Collapse
|
28
|
Abstract
Periprosthetic osteolysis remains the leading complication of total hip arthroplasty, often resulting in aseptic loosening of the implant, and a requirement for revision surgery. Wear-generated particular debris is the main cause of initiating this destructive process. The purpose of this article is to review recent advances in our understanding of how wear debris causes osteolysis, and emergent strategies for the avoidance and treatment of this disease. The most important cellular target for wear debris is the macrophage, which responds to particle challenge in two distinct ways, both of which contribute to increased bone resorption. First, it is well known that wear debris activates proinflammatory signaling, which leads to increased osteoclast recruitment and activation. More recently, it has been established that wear also inhibits the protective actions of antiosteoclastogenic cytokines such as interferon gamma, thus promoting differentiation of macrophages to bone-resorbing osteoclasts. Osteoblasts, fibroblasts, and possibly lymphocytes may also be involved in responses to wear. At a molecular level, wear particles activate MAP kinase cascades, NFkappaB and other transcription factors, and induce expression of suppressors of cytokine signaling. Strategies to reduce osteolysis by choosing bearing surface materials with reduced wear properties (such as metal-on-metal) should be balanced by awareness that reducing particle size may increase biological activity. Finally, although therapeutic agents against proinflammatory mediators [such as tumor necrosis factor (TNF)] and osteoclasts (bisphosphonates and molecules blocking RANKL signaling) have shown promise in animal models, no approved treatments are yet available to osteolysis patients. Considerable efforts are underway to develop such therapies, and to identify novel targets for therapeutic intervention.
Collapse
Affiliation(s)
- P. Edward Purdue
- Osteolysis Research Laboratory, Hospital for Special Surgery, 535 East 70th Street, New York, NY 10021 USA
| | - Panagiotis Koulouvaris
- Osteolysis Research Laboratory, Hospital for Special Surgery, 535 East 70th Street, New York, NY 10021 USA
| | - Bryan J. Nestor
- Osteolysis Research Laboratory, Hospital for Special Surgery, 535 East 70th Street, New York, NY 10021 USA
| | - Thomas P. Sculco
- Osteolysis Research Laboratory, Hospital for Special Surgery, 535 East 70th Street, New York, NY 10021 USA
| |
Collapse
|
29
|
Wang J, Diaz J, Sabokbar A, Athanasou N, Kjellson F, Tanner K, McCarthy I, Lidgren L. In vitro and in vivo biological responses to a novel radiopacifying agent for bone cement. J R Soc Interface 2006; 2:71-8. [PMID: 16849166 PMCID: PMC1578263 DOI: 10.1098/rsif.2004.0009] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Iodixanol (IDX) and iohexol (IHX) have been investigated as possible radiopacification agents for polymethylmethacrylate (PMMA) bone cement, to replace the currently used barium sulphate and zirconia. IDX and IHX are both water-soluble iodine-based contrast media and for the last 20 years have been used extensively in clinical diagnostic procedures such as contrast media enhanced computed tomography, angiography and urography. One of the major reasons to remove the current radiopacifying agents is their well-documented cytotoxicity and their potential to increase bone resorption. Using in vitro bone resorption assays, the effect of PMMA particles plus IDX or IHX to induce osteoclast formation and lacunar resorption on dentine slices has been investigated. These responses have been compared with the in vitro response to PMMA particles containing the conventional radiopacifying agents, that is, barium sulphate and zirconia. In parallel, the in vivo reaction, in terms of new bone formation, to particles of these materials has been tested using a bone harvest chamber in rabbit tibiae. In vitro cell culture showed that PMMA containing IHX resulted in significantly less bone resorption than PMMA containing the conventional opacifiers. In vivo testing, however, showed no significant differences between the amounts of new bone formed around cement samples containing the two iodine-based opacifying agents in particulate form, although both led to fewer inflammatory cells than particles of PMMA containing zirconia. Our results suggest that a non-ionic radiopacifier could be considered as an alternative to the conventional radiopacifying agents used in biomaterials in orthopaedic surgery.
Collapse
Affiliation(s)
- J.S Wang
- Department of Orthopaedics, Lund UniversityLund 22185, Sweden
| | - J Diaz
- Nuffield Orthopaedic CentreWindmill Road, Headington, Oxford OX3 7LD, UK
| | - A Sabokbar
- Nuffield Orthopaedic CentreWindmill Road, Headington, Oxford OX3 7LD, UK
| | - N Athanasou
- Nuffield Orthopaedic CentreWindmill Road, Headington, Oxford OX3 7LD, UK
| | - F Kjellson
- Department of Orthopaedics, Lund UniversityLund 22185, Sweden
| | - K.E Tanner
- Department of Materials, Queen Mary University of LondonMile End Road, London E1 4NS, UK
- Author for correspondence ()
| | - I.D McCarthy
- Department of Orthopaedics, Lund UniversityLund 22185, Sweden
| | - L Lidgren
- Department of Orthopaedics, Lund UniversityLund 22185, Sweden
| |
Collapse
|
30
|
von Schewelov T, Carlsson A, Dahlberg L. Cross-linked N-telopeptide of type I collagen (NTx) in urine as a predictor of periprosthetic osteolysis. J Orthop Res 2006; 24:1342-8. [PMID: 16718682 DOI: 10.1002/jor.20152] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Periprosthetic osteolysis is often nonsymptomatic and hard to visualize by conventional radiography. Cross-linked N-telopeptide of type I collagen (NTx), a marker of osteoclast mediated bone resorption, has been suggested to evaluate local particulate-induced osteolysis in patients operated on with a total hip prosthesis. Urine specimens were sampled after hip joint replacement in 160 patients. NTx was analyzed by a commercially available ELISA kit. Osteolysis was identified in the acetabulum and confirmed at operation. Using analysis of covariance to correct for differences in age, gender, and time after operation, NTx (mean SD) was 36+/-12 BCE/nM creatinine in patients with osteolysis (n=33) and 27+/-13 BCE/nM creatinine in patients without osteolysis (n=127) (p=0.003). Eighteen hips of 38 (47%), demonstrating an annual wear of more than 0.2 mm and an NTx value above 29 BCE/nM creatinine, had been revised due to osteolysis. The osteolysis prevalence in this group was increased 10 times (CI 4-23, p<0.05). Indeed, NTx release and annual wear were both associated with increased prevalence of osteolysis, however, independently of each other. NTx seems a feasible marker of periprosthetic osteolysis. A preoperative baseline NTx level is likely needed for its use as a predictor of periprosthetic osteolysis in individual cases.
Collapse
Affiliation(s)
- Thord von Schewelov
- Department of Orthopedics, Lund University, Malmö University Hospital, SE-205 02 Malmö, Sweden.
| | | | | |
Collapse
|
31
|
Sun SG, Ma BA, Zhou Y, Zhang MH, Fan QY. Effects of bone cement particles on the function of pseudocapsule-derived fibroblasts. Acta Orthop 2006; 77:320-8. [PMID: 16752297 DOI: 10.1080/17453670610046091] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND Despite the wide clinical use of bone cement, little is known about cellular responses to the debris from this material. We thus investigated the effects of bone cement particles on the secretion of soluble osteotropic factors in prosthetic pseudomembrane-derived fibroblasts. METHODS Bone cement particles were added to fibroblasts maintained in tissue culture. The secretions of soluble receptor activator for nuclear factor kappa B ligand and osteoprotegerin together with interleukin-6 and tumor necrosis factor-alpha were assessed by enzyme-linked immunosorbent assays. The fibroblasts were also co-cultured with osteoclast precursors in the presence and absence of particles, and we assessed osteoclast formation and bone resorption. RESULTS The particles produced an increase in the secretion of soluble receptor activator for nuclear factor kappa B ligand, interleukin-6 and tumor necrosis factor-alpha, but not osteoprotegerin. At a concentration of 88 particles/cell, bone cement particles yielded a 2-fold increase (327 pg/mL) in soluble receptor activator for nuclear factor kappa B ligand secretion, a 5-fold (239 pg/mL) increase in interleukin-6 secretion and 4-fold (129 pg/mL) increase in tumor necrosis factor-alpha secretion. The particles also enhanced bone resorption in the co-culture group. Both the increase in soluble receptor activator for nuclear factor kappa B ligand secretion and the increase in bone resorption were inhibited by the addition of neutralizing antibodies to the proinflammatory cytokines. INTERPRETATION Our findings show that bone cement particles are capable of stimulating the secretion of soluble receptor activator for nuclear factor kappa B ligand in pseudocapsule-derived fibroblasts by increasing the secretion of proinflammatory cytokines, and may also promote implant loosening.
Collapse
Affiliation(s)
- Si Guo Sun
- Department of Orthopedic Surgery, Tangdu Hospital, the Fourth Military Medical University, Xi'an, 710038. China
| | | | | | | | | |
Collapse
|
32
|
Evans CE, Mylchreest S, Mee AP, Berry JL, Andrew JG. Cyclic hydrostatic pressure and particles increase synthesis of 1,25-dihydroxyvitamin D3 by human macrophages in vitro. Int J Biochem Cell Biol 2006; 38:1540-6. [PMID: 16690344 DOI: 10.1016/j.biocel.2006.03.004] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2005] [Revised: 03/09/2006] [Accepted: 03/10/2006] [Indexed: 10/24/2022]
Abstract
1,25-Dihydroxyvitamin D(3) has a pivotal role in bone resorption and osteoclast activity. As activated macrophages are known to synthesise 1,25-dihydroxyvitamin D(3), this study examined whether pressure modulated its synthesis. Pressure and particles have been shown to increase synthesis of pro-resorptive cytokines and other factors by cultured macrophages. Human peripheral blood macrophages were isolated, cultured and exposed to pressure (similar to that found in the human joint) and/or particles. Synthesis of 1,25-dihydroxyvitamin D(3) by macrophages was assayed using high pressure liquid chromatography and in situ hybridization. Synthesis of 1,25-dihydroxyvitamin D(3) but not 24,25-dihydroxyvitamin D(3) was increased in macrophages under pressure. In situ hybridization demonstrated an increase in 1alpha-hydroxylase expression in response to pressure or particles and simultaneous exposure to both stimuli generated higher expression of 1alpha-hydroxylase. In conclusion, this is the first study to demonstrate that mechanical loading, in the form of pressure, stimulates 1,25-dihydroxyvitamin D(3) synthesis in human macrophages. These findings have implications for the in vivo situation, as they suggest that 1,25-dihydroxyvitamin D(3) could be one factor stimulating osteoclastic bone resorption in pathologies, such as arthritis or implant loosening, where intra-articular or intra-osseous pressure is raised or where wear particles interact with macrophages.
Collapse
Affiliation(s)
- C E Evans
- Division of Laboratory & Regenerative Medicine, Stopford Building, The Medical School, University of Manchester, Oxford Road, Manchester M13 9PT, UK.
| | | | | | | | | |
Collapse
|
33
|
Evans CE, Mylchreest S, Andrew JG. Age of donor alters the effect of cyclic hydrostatic pressure on production by human macrophages and osteoblasts of sRANKL, OPG and RANK. BMC Musculoskelet Disord 2006; 7:21. [PMID: 16519799 PMCID: PMC1475864 DOI: 10.1186/1471-2474-7-21] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2005] [Accepted: 03/06/2006] [Indexed: 11/29/2022] Open
Abstract
Background Cyclic hydrostatic pressure within bone has been proposed both as a stimulus of aseptic implant loosening and associated bone resorption and of bone formation. We showed previously that cyclical hydrostatic pressure influenced macrophage synthesis of several factors linked to osteoclastogenesis. The osteoprotegerin/soluble receptor activator of NF-kappa β ligand /receptor activator of NF-kappa β (OPG/ RANKL/ RANK) triumvirate has been implicated in control of bone resorption under various circumstances. We studied whether cyclical pressure might affect bone turnover via effects on OPG/ sRANKL/ RANK. Methods In this study, cultures of human osteoblasts or macrophages (supplemented with osteoclastogenic factors) or co-cultures of macrophages and osteoblasts (from the same donor), were subjected to cyclic hydrostatic pressure. Secretion of OPG and sRANKL was assayed in the culture media and the cells were stained for RANK and osteoclast markers. Data were analysed by nonparametric statistics. Results In co-cultures of macrophages and osteoblasts, pressure modulated secretion of sRANKL or OPG in a variable manner. Examination of the OPG:sRANKL ratio in co cultures without pressurisation showed that the ratio was greater in donors <70 years at the time of operation (p < 0.05 Mann Whitney U) than it was in patients >70 years. However, with pressure the difference in the OPG:sRANKL ratios between young and old donors was not significant. It was striking that in some patients the OPG:sRANKL ratio increased with pressure whereas in some it decreased. The tendency was for the ratio to decrease with pressure in patients younger than 70 years, and increase in patients ≥ 70 years (Fishers exact p < 0.01). Cultures of osteoblasts alone showed a significant increase in both sRANKL and OPG with pressure, and again there was a decrease in the ratio of OPG:RANKL. Secretion of sRANKL by cultures of macrophages alone was not modulated by pressure. Only sRANKL was assayed in this study, but transmembrane RANKL may also be important in this system. Macrophages subjected to pressure (both alone and in co-culture) stained more strongly for RANK on immunohistochemstry than non-pressurized controls and 1,25-dihydroxyvitamin D3 (1,25 D3) further increased this. Immunocytochemical staining also demonstrated that more cells in pressurized co-cultures exhibited osteoclast markers (tartrate-resistant acid phosphatase, vitronectin receptor and multinuclearity) than did unpressurized controls. Conclusion These data show that in co-cultures of osteoblasts and macrophages the ratio of OPG : sRANKL was decreased by pressure in younger patients but increased in older patients. As falls in this ratio promote bone resorption, this finding may be important in explaining the relatively high incidence of osteolysis around orthopaedic implants in young patients. The finding that secretion of OPG and sRANKL by osteoblasts in monoculture was sensitive to hydrostatic pressure, and that hydrostatic pressure stimulated the differentiation of macrophages into cells exhibiting osteoclast markers indicates that both osteoblasts and preosteoclasts are sensitive to cyclic pressure. However, the effects of pressure on cocultures were not simply additive and coculture appears useful to examine the interaction of these cell types. These findings have implications for future therapies for aseptic loosening and for the development of tests to predict the development of this condition.
Collapse
Affiliation(s)
- CE Evans
- Laboratory & Regenerative Medicine, Stopford Building, The Medical School, University of Manchester, Oxford Road, Manchester M13 9PT, UK
| | - S Mylchreest
- Laboratory & Regenerative Medicine, Stopford Building, The Medical School, University of Manchester, Oxford Road, Manchester M13 9PT, UK
| | - JG Andrew
- Department of Orthopaedic Surgery, Ysbyty Gwynedd, Bangor, LL57 2PW, UK
| |
Collapse
|
34
|
Ingham E, Fisher J. The role of macrophages in osteolysis of total joint replacement. Biomaterials 2005; 26:1271-86. [PMID: 15475057 DOI: 10.1016/j.biomaterials.2004.04.035] [Citation(s) in RCA: 379] [Impact Index Per Article: 19.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2003] [Accepted: 04/19/2004] [Indexed: 12/12/2022]
Abstract
The osteolysis associated with conventional polyethylene on metal total joint replacements is associated with the formation of an inflamed periprosthetic membrane rich in macrophages, cytokines and implant-derived wear particles. There is a wealth of evidence to indicate that the presence and activation of macrophages in the periprosthetic tissues around joint replacements is stimulated by UHMWPE particles. Particles within the size range 0.1-1.0 microm have been shown to be the most reactive. Animal studies have provided increasing evidence that, of the milieu of cytokines produced by particle-stimulated macrophages, TNF-alpha is a key cytokine involved in osteolysis. Recent advances in the understanding of the mechanisms of osteoclastogenesis and osteoclast activation at the cellular and molecular level have indicated that bone marrow-derived macrophages may play a dual role in osteolysis associated with total joint replacement. Firstly, as the major cell in host defence responding to UHMWPE particles via the production of cytokines and secondly as precursors for the osteoclasts responsible for the ensuing bone resorption.
Collapse
Affiliation(s)
- Eileen Ingham
- School of Biochemistry and Molecular Biology, Institute of Medical and Biological Engineering, Division of Microbiology, University of Leeds, Leeds LS2 9JT, UK.
| | | |
Collapse
|
35
|
Haynes DR, Crotti TN, Zreiqat H. Regulation of osteoclast activity in peri-implant tissues. Biomaterials 2004; 25:4877-85. [PMID: 15109848 DOI: 10.1016/j.biomaterials.2004.01.003] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2003] [Accepted: 12/27/2003] [Indexed: 01/22/2023]
Abstract
Implants, particularly joint replacement prostheses, are one of the great success stories of modern medicine. However, too many implants fail prematurely, mainly due to aseptic bone loss around the implant. This paper reviews our current understanding of the role of osteoclasts in this peri-implant bone lysis. Prosthetic particles, often produced by articulating prostheses, are one of the major causes of elevated osteoclast lysis of peri-implant bone. Over the past decade there have been major advances in our understanding of the factors that regulate osteoclast activity, many of which were found to be important in osteoclast formation and activity in the peri-implant tissues. These factors are targets of a number of recently developed drugs that have been used successfully to prevent and treat peri-implant bone lysis in experimental models. Treatments such as these are being used in a number of bone loss pathologies in humans and have the potential for successful treatment of peri-implant osteolysis. In addition, understanding how different biomaterials influence the expression of key osteoclastogenic factors may allow us to select biomaterials for implantation that will last the lifetime of the recipient.
Collapse
Affiliation(s)
- D R Haynes
- Department of Pathology, University of Adelaide, Adelaide, 5005 South Australia, Australia.
| | | | | |
Collapse
|
36
|
Abstract
Implants, particularly joint replacement prostheses, are one of the great success stories of modern medicine. However, too many implants fail prematurely, mainly due to aseptic bone loss around the implant. This paper reviews our current understanding of the role of osteoclasts in this peri-implant bone lysis. Prosthetic particles, often produced by articulating prostheses, are one of the major causes of elevated osteoclast lysis of peri-implant bone. Over the past decade there have been major advances in our understanding of the factors that regulate osteoclast activity, many of which were found to be important in osteoclast formation and activity in the peri-implant tissues. These factors are targets of a number of recently developed drugs that have been used successfully to prevent and treat peri-implant bone lysis in experimental models. Treatments such as these are being used in a number of bone loss pathologies in humans and have the potential for successful treatment of peri-implant osteolysis. In addition, understanding how different biomaterials influence the expression of key osteoclastogenic factors may allow us to select biomaterials for implantation that will last the lifetime of the recipient.
Collapse
Affiliation(s)
- D R Haynes
- Department of Pathology, University of Adelaide, Adelaide, 5005 South Australia, Australia.
| | | | | |
Collapse
|
37
|
Massin P, Chappard D, Flautre B, Hardouin P. Migration of polyethylene particles around nonloosened cemented femoral components from a total hip arthroplasty-an autopsy study. J Biomed Mater Res B Appl Biomater 2004; 69:205-15. [PMID: 15116410 DOI: 10.1002/jbm.b.30001] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Three cemented femoral components from total hip arthroplasties retrieved at autopsy were examined in regard to the migration of birefringent polyethylene particles across the fixation interfaces. They were obtained from two patients who died from unrelated causes. They had been in place, respectively, for 8 and 9 years (first patient) and for 9 years (second patient). Osteolysis was present in the acetabular side only. The femoral components were not loosened. Histologic sections were performed at four levels of the femoral components, and polyethylene particles were counted with the use of a semiautomatic image analyzer. Sections below the tip of the stem were treated by deorganification and the lysate was centrifuged in the attempt to isolate wear debris. Particles were found at both interfaces (bone-cement and metal-cement) and in the cancellous bone between the trabeculae. They were also present in the Haversian canals of the cortical bone. Particles of various sizes were found in the medullary canal beneath the tip of the stem. In scanning electron microscopy, they appeared to have irregular shapes. Wear debris can migrate across the cement-bone interface of nonloosened implants. They appear to progress through the porosity of the cancellous bone.
Collapse
Affiliation(s)
- Philippe Massin
- Department of Orthopaedic Surgery, Angers University Hospital, 4 rue Larrey, 49033 Angers CEDEX 01, France.
| | | | | | | |
Collapse
|
38
|
Fujishiro T, Nishikawa T, Shibanuma N, Akisue T, Takikawa S, Yamamoto T, Yoshiya S, Kurosaka M. Effect of cyclic mechanical stretch and titanium particles on prostaglandin E2 production by human macrophages in vitro. J Biomed Mater Res A 2004; 68:531-6. [PMID: 14762933 DOI: 10.1002/jbm.a.20098] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Early implant instability has been proposed as a critical factor in the onset and progression of aseptic loosening and periprosthetic osteolysis in total joint arthroplasties. Previous in vitro studies have reported that macrophages stimulated with cyclic mechanical strain release inflammatory mediators. Little is known, however, about the response of these cells to mechanical strain with particles, which is often a component of the physical environment of the cell. We therefore studied the production of prostaglandin E(2) (PGE(2)), an important mediator in aseptic loosening and periprosthetic osteolysis in total joint arthroplasties, for human macrophages treated with mechanical stretch alone, titanium particles alone, and mechanical stretch and particles combined. A combination of mechanical stretch and titanium particles resulted in a statistically synergistic elevation of levels of PGE(2) compared with the levels found with either stretch or particles alone. Exposure of human macrophages to mechanical stretch with particles upregulated the expression of cyclooxygenase (COX)-2 mRNA but not COX-1 mRNA, this expression resulting in a 97-fold increase in PGE(2) production compared to the nonstimulated cells. The current study is the first to investigate the effects of mechanical stretch with particles on cultured macrophages and include an investigation of the time course of PGE(2) production and COX-2 mRNA expression. Our results suggest that, while mechanical strain may be one of the primary factors responsible for macrophage activation and periprosthetic osteolysis, mechanical strain with particles load may contribute significantly to the osteolytic potential of macrophages in vitro. The synergistic effect observed between mechanical stretch and particles could accelerate implant loosening and implies that reduction in either cyclic mechanical strain or wear debris load would lead to a reduction of osteolysis.
Collapse
Affiliation(s)
- Takaaki Fujishiro
- Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1, Kusunoki-cho, Chuo-ku, Kobe 650-0017, Japan.
| | | | | | | | | | | | | | | |
Collapse
|
39
|
Greenfield EM, Bi Y, Ragab AA, Goldberg VM, Nalepka JL, Seabold JM. Does endotoxin contribute to aseptic loosening of orthopedic implants? ACTA ACUST UNITED AC 2004; 72:179-85. [PMID: 15449253 DOI: 10.1002/jbm.b.30150] [Citation(s) in RCA: 117] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Aseptic loosening of orthopedic implants caused by wear particles is a major clinical problem. This review examines the hypothesis that bacterial endotoxin contributes to aseptic loosening. Clinical findings support this hypothesis: bacterial biofilms exist on many implants from patients with aseptic loosening and antibiotics in bone cement reduce the rate of aseptic loosening. Three approaches were used to demonstrate that adherent endotoxin increases bioactivity of titanium particles. These experiments measured cytokine production and osteoclast differentiation in vitro and murine calvarial osteolysis in vivo. First, removal of >99.9% of the adherent endotoxin from titanium particles significantly ablates their biological activity. Second, adding lipopolysaccharide back to these "endotoxin-free" particles restores their biological activity. Third, cells or mice that are genetically hyporesponsive to endotoxin are significantly less responsive to titanium particles than are wild-type controls. Other investigators have confirmed and extended these results to include virtually all orthopedically relevant types of particles, including authentic titanium alloy particles retrieved from patients with loosening. Our recent studies suggest that adherent endotoxin on orthopedic implants may also inhibit initial osseointegration of the implants. Taken together, these studies suggest that bacterial endotoxin may have a significant role in induction of aseptic loosening.
Collapse
Affiliation(s)
- Edward M Greenfield
- Department of Orthopaedics, Case Western Reserve University, University Hospitals of Cleveland, Cleveland, OH 44106-5000, USA.
| | | | | | | | | | | |