Almog N, Zgadzai O, Kuppusamy P, Zur Y, Baruch L, Machluf M, Blank A. Hand-held electron spin resonance scanner for subcutaneous oximetry using OxyChip. Magn Reson Med 2024; 92:430-439. [PMID: 38411265 PMCID: PMC11055674 DOI: 10.1002/mrm.30066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2024] [Revised: 02/07/2024] [Accepted: 02/08/2024] [Indexed: 02/28/2024]
Abstract
PURPOSE Electron spin resonance (ESR) is used to measure oxygen partial pressure (pO2) in biological media with many clinical applications. Traditional clinical ESR involves large magnets that encompass the subject of measurement. However, certain applications might benefit from a scanner operating within local static magnetic fields. Our group recently developed such a compact scanner for transcutaneous (surface) pO2 measurements of skin tissue. Here we extend this capability to subsurface (subcutaneous) pO2 measurements and verify it using an artificial tissue emulating (ATE) phantom. METHODS We introduce a new scanner, tailored for subcutaneous measurements up to 2 mm beneath the skin's surface. This scanner captures pulsed ESR signals from embedded approximate 1-mm oxygen-sensing solid paramagnetic implant, OxyChip. The scanner features a static magnetic field source, producing a uniform region outside its surface, and a compact microwave resonator, for exciting and receiving ESR signals. RESULTS ESR readings derived from an OxyChip, positioned approximately 1.5 mm from the scanner's surface, embedded in ATE phantom, exhibited a linear relation of 1/T2 versus pO2 for pO2 levels at 0, 7.6, 30, and 160 mmHg, with relative reading accuracy of about 10%. CONCLUSION The compact ESR scanner can report pO2 data in ATE phantom from an external position relative to the scanner. Implementing this scanner in preclinical and clinical applications for subcutaneous pO2 measurements is a feasible next phase for this development. This innovative design also has the potential to operate in conjunction with artificial skin graft for wound healing, combining therapeutic and pO2 diagnostic features.
Collapse
Affiliation(s)
- Nir Almog
- Schulich Faculty of Chemistry, Technion – Israel Institute of Technology, Haifa 32000, Israel
| | - Oleg Zgadzai
- Schulich Faculty of Chemistry, Technion – Israel Institute of Technology, Haifa 32000, Israel
| | - Periannan Kuppusamy
- Departments of Radiology, Radiation Oncology, and Medicine, Geisel School of Medicine, Dartmouth College, Lebanon, NH 03756, USA
| | - Yehonatan Zur
- Faculty of Biotechnology and Food Engineering, Technion – Israel Institute of Technology, Haifa 32000, Israel
| | - Limor Baruch
- Faculty of Biotechnology and Food Engineering, Technion – Israel Institute of Technology, Haifa 32000, Israel
| | - Marcelle Machluf
- Faculty of Biotechnology and Food Engineering, Technion – Israel Institute of Technology, Haifa 32000, Israel
| | - Aharon Blank
- Schulich Faculty of Chemistry, Technion – Israel Institute of Technology, Haifa 32000, Israel
| |
Collapse
|
2
|
Šedivý M, Santana V, Sojka A, Laguta O, Neugebauer P. MEPROS - Modular electron paramagnetic resonance operating software for multifunctional high-frequency EPR spectrometer. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2023; 355:107556. [PMID: 37751649 DOI: 10.1016/j.jmr.2023.107556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 09/07/2023] [Accepted: 09/11/2023] [Indexed: 09/28/2023]
Abstract
We present a software solution developed in LabVIEW for a home-built High-Frequency Electron Paramagnetic Resonance (HF-EPR) spectrometer. A modular approach was applied to control the spectrometer subsystems and simplify the adaptation to hardware changes during the development. The solution implements measuring procedures for conventional Continuous Wave EPR (CW-EPR), Frequency-Swept EPR (FS-EPR), and Two-Dimensional EPR (2D-EPR) mapping, which are relevant in different cases. The software's automation capabilities were tested in several trial measurements to obtain CW-EPR spectra of Silicon Carbide doped by vanadium (SiC + V) at various temperatures and microwave frequencies, multi-frequency spectra via 2D-EPR mapping, and dense FS-EPR data of a lithium phthalocyanine crystal rotated in a magnetic field. Several prospective modifications of the software are discussed in the conclusion. A modular character allows the easy re-use of code portions in other experimental setups. The spectrometer and the software are currently deployed and utilized in a laboratory of EPR spectroscopy at Central European Institute of Technology (CEITEC) in Brno, and data obtained by it has been already used in a number of publications.
Collapse
Affiliation(s)
- Matúš Šedivý
- Magneto-Optical and THz Spectroscopy, Central European Institute of Technology (CEITEC), Brno University of Technology (BUT), Czech Republic; Department of Microelectronics, Faculty of Electrical Engineering and Communication, Brno University of Technology, Czech Republic.
| | - Vinicius Santana
- Magneto-Optical and THz Spectroscopy, Central European Institute of Technology (CEITEC), Brno University of Technology (BUT), Czech Republic
| | - Antonín Sojka
- Magneto-Optical and THz Spectroscopy, Central European Institute of Technology (CEITEC), Brno University of Technology (BUT), Czech Republic
| | - Oleksii Laguta
- Magneto-Optical and THz Spectroscopy, Central European Institute of Technology (CEITEC), Brno University of Technology (BUT), Czech Republic
| | - Petr Neugebauer
- Magneto-Optical and THz Spectroscopy, Central European Institute of Technology (CEITEC), Brno University of Technology (BUT), Czech Republic.
| |
Collapse
|
3
|
Sojka A, Price BD, Sherwin MS. Order-of-magnitude SNR improvement for high-field EPR spectrometers via 3D printed quasi-optical sample holders. SCIENCE ADVANCES 2023; 9:eadi7412. [PMID: 37729398 PMCID: PMC10511183 DOI: 10.1126/sciadv.adi7412] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Accepted: 08/18/2023] [Indexed: 09/22/2023]
Abstract
Here, we present a rapidly prototyped, cost-efficient, and 3D printed quasi-optical sample holder for improving the signal-to-noise ratio (SNR) in modern, resonator-free, and high-field electron paramagnetic resonance (HFEPR) spectrometers. Such spectrometers typically operate in induction mode: The detected EPR ("cross-polar") signal is polarized orthogonal to the incident ("co-polar") radiation. The sample holder makes use of an adjustable sample positioner that allows for optimizing the sample position to maximize the 240-gigahertz magnetic field B1 and a rooftop mirror that allows for small rotations of the microwave polarization to maximize the cross-polar signal and minimize the co-polar background. When optimally tuned, the sample holder was able to improve co-polar isolation by ≳20 decibels, which is proven beneficial for maximizing the SNR in rapid-scan, pulsed, and continuous-wave EPR experiments. In rapid-scan mode, the improved SNR enabled the recording of entire EPR spectra of a narrow-line radical in millisecond time scales, which, in turn, enabled real-time monitoring of a sample's evolving line shape.
Collapse
Affiliation(s)
- Antonín Sojka
- Department of Physics, University of California, Santa Barbara, Santa Barbara, CA, USA
- Institute for Terahertz Science and Technology, University of California, Santa Barbara, Santa Barbara, CA 93106, USA
| | - Brad D. Price
- Department of Physics, University of California, Santa Barbara, Santa Barbara, CA, USA
- Institute for Terahertz Science and Technology, University of California, Santa Barbara, Santa Barbara, CA 93106, USA
| | - Mark S. Sherwin
- Department of Physics, University of California, Santa Barbara, Santa Barbara, CA, USA
- Institute for Terahertz Science and Technology, University of California, Santa Barbara, Santa Barbara, CA 93106, USA
| |
Collapse
|
4
|
O'Connell RC, Tseytlin O, Bobko AA, Eubank TD, Tseytlin M. Rapid scan EPR: Automated digital resonator control for low-latency data acquisition. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2022; 345:107308. [PMID: 36356489 PMCID: PMC10266206 DOI: 10.1016/j.jmr.2022.107308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/20/2022] [Revised: 10/05/2022] [Accepted: 10/06/2022] [Indexed: 06/05/2023]
Abstract
Automation has become an essential component of modern scientific instruments which often capture large amounts of complex dynamic data. Algorithms are developed to read multiple sensors in parallel with data acquisition and to adjust instrumental parameters on the fly. Decisions are made on a time scale unattainable to the human operator. In addition to speed, automation reduces human error, improves the reproducibility of experiments, and improves the reliability of acquired data. An automatic digital control (ADiC) was developed to reliably sustain critical coupling of a resonator over a wide range of time-varying loading conditions. The ADiC uses the computational power of a microcontroller that directly communicates with all system components independent of a personal computer (PC). The PC initiates resonator tuning and coupling by sending a command to MC via serial port. After receiving the command, ADiC establishes critical coupling conditions within approximately 5 ms. A printed circuit board resonator was designed to permit digital control. The performance of the resonator together with the ADiC was evaluated by varying the resonator loading from empty to heavily loaded. For the loading, samples containing aqueous sodium chloride that strongly absorb electromagnetic waves were used. A previously reported rapid scan (RS) electron paramagnetic resonance (EPR) imaging instrument was upgraded by the incorporation of ADiC. RS spectra and an in vivo image of oxygen in a mouse tumor model have been acquired using the upgraded system. ADiC robustly sustained critical coupling of the resonator to the transmission line during these measurements. The design implemented in this study can be used in slow-scan and pulsed EPR with modifications.
Collapse
Affiliation(s)
- Ryan C O'Connell
- Department of Biochemistry and Molecular Medicine, West Virginia University, Morgantown, WV 26506, USA; In Vivo Multifunctional Magnetic Resonance Center at Robert C. Byrd Health Sciences Center, West Virginia University, Morgantown, WV 26506, USA
| | - Oxana Tseytlin
- Department of Biochemistry and Molecular Medicine, West Virginia University, Morgantown, WV 26506, USA; In Vivo Multifunctional Magnetic Resonance Center at Robert C. Byrd Health Sciences Center, West Virginia University, Morgantown, WV 26506, USA
| | - Andrey A Bobko
- Department of Biochemistry and Molecular Medicine, West Virginia University, Morgantown, WV 26506, USA; In Vivo Multifunctional Magnetic Resonance Center at Robert C. Byrd Health Sciences Center, West Virginia University, Morgantown, WV 26506, USA
| | - Timothy D Eubank
- In Vivo Multifunctional Magnetic Resonance Center at Robert C. Byrd Health Sciences Center, West Virginia University, Morgantown, WV 26506, USA; Department of Microbiology, Immunology and Cell Biology, West Virginia University, Morgantown, WV 26506, USA
| | - Mark Tseytlin
- Department of Biochemistry and Molecular Medicine, West Virginia University, Morgantown, WV 26506, USA; West Virginia University Cancer Institute, Morgantown, WV 26506, USA; In Vivo Multifunctional Magnetic Resonance Center at Robert C. Byrd Health Sciences Center, West Virginia University, Morgantown, WV 26506, USA.
| |
Collapse
|
5
|
Viswakarma N, Siddiqui E, Patel S, Hameed S, Schreiber W, Swartz HM, Epel B, Kotecha M. In Vivo Partial Oxygen Pressure Assessment in Subcutaneous and Intraperitoneal Sites Using Imaging of Solid Oxygen Probe. Tissue Eng Part C Methods 2022; 28:264-271. [PMID: 35509263 DOI: 10.1089/ten.tec.2022.0061] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
The purpose of this study was to assess the natural partial oxygen pressure (pO2) of subcutaneous (SC) and intraperitoneal (IP) sites in mice to determine their relative suitability as sites for placement of implants. The pO2 measurements were performed using oxygen imaging of solid probes using lithium phthalocyanine (LiPc) as the oxygen sensitive material. LiPc is a water-insoluble crystalline probe whose spin-lattice and spin-spin relaxation rates (R1 and R2) are sensitive to the local oxygen concentration. To facilitate direct in vivo oxygen imaging, we prepared a solid probe containing encapsulated LiPc crystals in polydimethylsiloxane (PDMS), an oxygen-permeable and bioinert polymer. Although LiPc-PDMS or similar probes have been used in repeated spectroscopic or average oxygen measurements using continuous wave electron paramagnetic resonance (EPR) since the late 1990s and now have advanced to clinical applications, they have not been used for pulse EPR oxygen imaging. One LiPc-PDMS probe of 2 mm diameter and 10 mm length was implanted in SC or IP sites (left or right side) in each animal. The pO2 imaging of implanted LiPc-PDMS probes was performed weekly for 6 weeks using O2M preclinical 25 mT oxygen imager, JIVA-25™, using the pulse inversion recovery electron spin echo method. At week 6, the probes were recovered, and histological examinations were performed. We report in this study, first-ever solid probe oxygen imaging of implanted devices and pO2 assessment of SC and IP sites.
Collapse
Affiliation(s)
- Navin Viswakarma
- Oxygen Measurement Core, O2M Technologies, LLC, Chicago, Illinois, USA
| | - Eliyas Siddiqui
- Oxygen Measurement Core, O2M Technologies, LLC, Chicago, Illinois, USA
| | - Sonny Patel
- Oxygen Measurement Core, O2M Technologies, LLC, Chicago, Illinois, USA
| | - Safa Hameed
- Oxygen Measurement Core, O2M Technologies, LLC, Chicago, Illinois, USA
| | | | | | - Boris Epel
- Oxygen Measurement Core, O2M Technologies, LLC, Chicago, Illinois, USA.,Department of Radiation and Cellular Oncology, The University of Chicago, Chicago, Illinois, USA
| | | |
Collapse
|
6
|
Cristea D, Wolfson H, Ahmad R, Twig Y, Kuppusamy P, Blank A. Compact electron spin resonance skin oximeter: Properties and initial clinical results. Magn Reson Med 2020; 85:2915-2925. [PMID: 33210362 DOI: 10.1002/mrm.28595] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2020] [Revised: 10/22/2020] [Accepted: 10/22/2020] [Indexed: 01/22/2023]
Abstract
PURPOSE Skin oxygen level is of significance for the diagnosis and treatment of many clinical problems, such as chronic wounds and diabetic foot ulcers. Furthermore, skin oxygen levels can be correlated to arterial oxygen partial pressure, thereby revealing potentially dangerous conditions such as hyperoxia (too much oxygen), which may occur in ventilated neonates. Traditionally, skin oxygen levels are measured using electrochemical methods and, more recently, also by fluorescence lifetime techniques. These approaches suffer from several drawbacks, rendering them suboptimal. The purpose of this work is to develop an electron spin resonance (ESR) -based method for monitoring oxygen partial pressure (pO2 ) in skin tissue. METHODS A compact sensor for pulsed ESR is designed and constructed. Our ESR-based method makes use of a unique exogenous paramagnetic spin probe that is placed on the skin in a special partially sealed sticker, and subsequently measuring its signal with the compact pulsed ESR sensor that includes a miniature magnet and a small S-band (~2.3 GHz) microwave resonator. The inverse of the spin-spin relaxation time (1/T2 ) measured by ESR is shown to be linearly correlated with pO2 levels. RESULTS The sensor and its matching sticker were tested both in vitro and in vivo (with human subjects). Measured skin pO2 levels reached equilibrium after ~2-3 h and were found to be comparable to those measured by continuous-wave (CW) ESR using a large electromagnet. CONCLUSIONS A compact pulsed ESR sensor with a matching paramagnetic sticker can be used for pO2 monitoring of the skin tissue, similar to large bulky CW ESR systems.
Collapse
Affiliation(s)
- David Cristea
- Schulich Faculty of Chemistry, Technion-Israel Institute of Technology, Haifa, Israel
| | - Helen Wolfson
- Schulich Faculty of Chemistry, Technion-Israel Institute of Technology, Haifa, Israel
| | - Rizwan Ahmad
- Department of Biomedical Engineering, Ohio State University, Columbus, Ohio, USA
| | - Ygal Twig
- Schulich Faculty of Chemistry, Technion-Israel Institute of Technology, Haifa, Israel
| | - Periannan Kuppusamy
- Departments of Radiology and Medicine, Geisel School of Medicine, Dartmouth College, Lebanon, New Hampshire, USA
| | - Aharon Blank
- Schulich Faculty of Chemistry, Technion-Israel Institute of Technology, Haifa, Israel
| |
Collapse
|
7
|
Pursley R, Enomoto A, Wu H, Brender JR, Pohida T, Subramanian S, Krishna MC, Devasahayam N. Towards reduction of SAR in scaling up in vivo pulsed EPR imaging to larger objects. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2019; 299:42-48. [PMID: 30579225 PMCID: PMC6753525 DOI: 10.1016/j.jmr.2018.12.011] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/25/2018] [Revised: 12/10/2018] [Accepted: 12/13/2018] [Indexed: 06/09/2023]
Abstract
An excessive RF power requirement is one of the main obstacles in the clinical translation of EPR imaging. The radio frequency (RF) pulses used in EPR imaging to excite electron spins must be very short to match their fast relaxation. With traditional pulse schemes and ninety degree flip angles, this can lead to either unsafe specific absorption rate (SAR) levels or unfeasibly long repetition times. In spectroscopy experiments, it has been shown that stochastic excitation and correlation detection can reduce the power while maintaining sensitivity but have yet to be applied to imaging experiments. Stochastic excitation is implemented using a pseudo-random phase modulation of the input stimulus. Using a crossed coil resonator assembly comprised of an outer saddle coil and an inner surface coil, it was possible to obtain a minimum isolation of ∼50 dB across a 12 MHz bandwidth. An incident peak RF power of 5 mW was used to excite the system. The low background signal obtained from this resonator allowed us to generate images with 32 dB (>1000:1) signal-to-noise ratio (SNR) while exciting with a traditional pulse sequence in a phantom containing the solid paramagnetic probe NMP-TCNQ (N-methyl pyridinium tetracyanoquinodimethane). Using two different stochastic excitation schemes, we were able to achieve a greater than 4-fold increase in SNR at the same peak power and number of averages, compared to single pulse excitation. This procedure allowed imaging at significantly lower RF power levels than used in conventional EPR imaging system configurations. Similar techniques may enable clinical applications for EPR imaging by facilitating the use of larger RF coils while maintaining a safe SAR level.
Collapse
Affiliation(s)
- Randall Pursley
- Signal Processing and Instrumentation Section, Computational Bioscience and Engineering Laboratory, Office of Intramural Research, National Institutes of Health, Bethesda, MD 20892, United States.
| | - Ayano Enomoto
- Radiation Biology Branch, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD 20892, United States; Department of Biophysical Chemistry, Nagasaki International University, Japan
| | - Haitao Wu
- Image Probe Development Center, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD 20892, United States
| | - Jeffrey R Brender
- Radiation Biology Branch, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD 20892, United States
| | - Thomas Pohida
- Signal Processing and Instrumentation Section, Computational Bioscience and Engineering Laboratory, Office of Intramural Research, National Institutes of Health, Bethesda, MD 20892, United States
| | - Sankaran Subramanian
- Radiation Biology Branch, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD 20892, United States; Indian Institute of Technology, Madras, Chennai, India
| | - Murali C Krishna
- Radiation Biology Branch, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD 20892, United States
| | - Nallathamby Devasahayam
- Radiation Biology Branch, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD 20892, United States
| |
Collapse
|
8
|
Abstract
EPR (electron paramagnetic resonance) based biological oximetry is a powerful tool that accurately and repeatedly measures tissue oxygen levels. In vivo determination of oxygen in tissues is crucial for the diagnosis and treatment of a number of diseases. Here, we report the first successful fabrication and remarkable properties of nanofiber sensors for EPR-oximetry applications. Lithium octa-n-butoxynaphthalocyanine (LiNc- BuO), an excellent paramagnetic oxygen sensor, was successfully encapsulated in 300-500 nm diameter fibers consisting of a core of polydimethylsiloxane (PDMS) and a shell of polycaprolactone (PCL) by electrospinning. This core-shell nanosensor (LiNc-BuO-PDMS-PCL) shows a linear dependence of linewidth versus oxygen partial pressure (pO2). The nanofiber sensors have response and recovery times of 0.35 s and 0.55 s, respectively, these response and recovery times are ~12 times and ~218 times faster than those previously reported for PDMS-LiNc-BuO chip sensors. This greater responsiveness is likely due to the high porosity and excellent oxygen permeability of the nanofibers. Electrospinning of the structurally flexible PDMS enabled the fabrication of fibers having tailored spin densities. Core-shell encapsulation ensures the non-exposure of embedded LiNc-BuO and mitigates potential biocompatibility concerns. In vitro evaluation of the fiber performed under exposure to cultured cells showed that it is both stable and biocompatible. The unique combination of biocompatibility due to the PCL 'shell,' the excellent oxygen transparency of the PDMS core, and the excellent oxygen-sensing properties of LiNc-BuO makes LiNc-BuO-PDMS-PCL platform promising for long-term oximetry and repetitive oxygen measurements in both biological systems and clinical applications.
Collapse
|
9
|
Takeshita K, Kinoshita S, Okazaki S. Simple Method for Quantification of Gadolinium Magnetic Resonance Imaging Contrast Agents Using ESR Spectroscopy. Chem Pharm Bull (Tokyo) 2012; 60:31-6. [DOI: 10.1248/cpb.60.31] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Affiliation(s)
- Keizo Takeshita
- Laboratory of Analytical Chemistry, Faculty of Pharmaceutical Sciences, Sojo University
| | - Shota Kinoshita
- Laboratory of Analytical Chemistry, Faculty of Pharmaceutical Sciences, Sojo University
| | - Shoko Okazaki
- Laboratory of Analytical Chemistry, Faculty of Pharmaceutical Sciences, Sojo University
| |
Collapse
|
10
|
Ahmad R, Kuppusamy P. Theory, instrumentation, and applications of electron paramagnetic resonance oximetry. Chem Rev 2010; 110:3212-36. [PMID: 20218670 PMCID: PMC2868962 DOI: 10.1021/cr900396q] [Citation(s) in RCA: 103] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Affiliation(s)
- Rizwan Ahmad
- Center for Biomedical EPR Spectroscopy and Imaging, Davis Heart and Lung Research Institute, Department of Internal Medicine, The Ohio State University, Columbus, Ohio 43210, USA
| | | |
Collapse
|
11
|
Takeshita K, Kawaguchi K, Fujii-Aikawa K, Ueno M, Okazaki S, Ono M, Krishna MC, Kuppusamy P, Ozawa T, Ikota N. Heterogeneity of regional redox status and relation of the redox status to oxygenation in a tumor model, evaluated using electron paramagnetic resonance imaging. Cancer Res 2010; 70:4133-40. [PMID: 20442282 DOI: 10.1158/0008-5472.can-09-4369] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
It is widely accepted that redox status, along with the partial pressure of oxygen (pO(2)), determines the efficacy of some therapeutic methods applied to treat tumors, including radiation. Redox status, evaluated by the reduction of a nitroxyl probe, was reportedly heterogeneous in a mouse tumor model. However, neither variation of heterogeneity of the redox status among mice nor the relation of the redox status to pO(2) in tumors has been characterized sufficiently. In this study, the regional reduction status in a mouse radiation-induced fibrosarcoma tumor model was evaluated using sequential three-dimensional electron paramagnetic resonance (EPR) imaging after i.v. injection of a tissue-permeable nitroxyl probe, HM-PROXYL. The regional decay of HM-PROXYL signal obeyed first-order kinetics, and the amplitude of the reduction rate and extent of its heterogeneity in a tumor varied among six mice. The tissue pO(2) was measured using EPR oximetry with lithium phthalocyanine (LiPc) microcrystals implanted within the tumor. The location of LiPc was determined with EPR imaging. A sequential image was obtained following the injection of HM-PROXYL, even after LiPc implantation, by choosing an HM-PROXYL signal peak which does not overlap with the signal of LiPc. The relationship between pO(2) and the reduction rate at the region of pO(2) measurement was found to be low (r = 0.357) in 13 tumor-bearing mice, indicating that the extent of oxygenation does not necessarily affect the redox status under air-breathing conditions. The results strongly indicate the necessity of measurements of both redox status and oxygenation in every tumor to characterize tumor physiology.
Collapse
Affiliation(s)
- Keizo Takeshita
- Faculty of Pharmaceutical Sciences, Sojo University, Kumamoto, Japan.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
In vivo measurement of tissue oxygen using electron paramagnetic resonance spectroscopy with oxygen-sensitive paramagnetic particle, lithium phthalocyanine. Methods Mol Biol 2010; 610:29-39. [PMID: 20013170 DOI: 10.1007/978-1-60327-029-8_2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
The partial pressure of oxygen (pO(2)) plays a determining role in the energy metabolism of aerobic cells. However, low pO(2) level induces pathophysiological conditions such as tumor hypoxia, ischemia or reperfusion injury, and delayed/altered wound healing. Especially, pO(2) level in the tumor is known to be related to tumor progression and effectiveness of radiotherapy. To monitor the pO(2) levels in vivo, continuous wave (CW) and time-domain (TD) electron paramagnetic resonance (EPR) spectroscopy method was used, in which surface coil resonator and Lithium phthalocyanine (LiPc) as oxygen sensor were crucial. Once LiPc particles are embedded in a desired location of organ/tissue, the pO(2) level can be monitored repeatedly and non-invasively. This method is based on the effect of oxygen concentration on the EPR spectra of LiPc which offers several advantages as follows: (1) high sensitivity, (2) minimum invasiveness, (3) repeated measurements, (4) absence of toxicity (non-toxic), and (5) measurement in a local region of the tissue with embedded LiPc. Therefore, in this chapter, we describe the method using CW and TD EPR spectroscopy with oxygen-sensitive particle, LiPc, for in vivo monitoring of oxygen.
Collapse
|
13
|
Abstract
The technique of electron paramagnetic resonance (EPR) spectroscopy is more than 50 years old, but only recently it has been used for in vivo studies. Its limited application in the past was due to the problem of high nonresonant dielectric loss of the exciting frequency because of high water content in biological samples. However, with the development of spectrometers working at lower frequencies (1,200 MHz and below) during the last 15 years, it is now possible to conduct in vivo measurements on a variety of animals and isolated organs. This is further facilitated by the development of new resonators with high sensitivity and appropriate stability for in vivo applications. It now has become feasible to obtain new insights into the complex aspects of physiology and pathophysiology using in vivo EPR. Among several important applications of this technique, the in vivo tissue pO(2) (partial pressure of oxygen) and redox measurements seem to be the most extensive use of this technique. In this chapter, we describe the procedure for in vivo pO(2) and redox measurements in animal models.
Collapse
|
14
|
Inagawa M, Yoshikawa H, Yokoyama T, Awaga K. Electrochemical structural transformation and reversible doping/dedoping of lithium phthalocyanine thin films. Chem Commun (Camb) 2009:3389-91. [DOI: 10.1039/b902903f] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
15
|
Pandian RP, Dolgos M, Marginean C, Woodward PM, Hammel PC, Manoharan PT, Kuppusamy P. Molecular packing and magnetic properties of lithium naphthalocyanine crystals: hollow channels enabling permeability and paramagnetic sensitivity to molecular oxygen. JOURNAL OF MATERIALS CHEMISTRY 2009; 19:4138-4147. [PMID: 19809598 PMCID: PMC2756769 DOI: 10.1039/b901886g] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The synthesis, structural framework, magnetic and oxygen-sensing properties of a lithium naphthalocyanine (LiNc) radical probe are presented. LiNc was synthesized in the form of a microcrystalline powder using a chemical method and characterized by electron paramagnetic resonance (EPR) spectroscopy, magnetic susceptibility, powder X-ray diffraction analysis, and mass spectrometry. X-Ray powder diffraction studies revealed a structural framework that possesses long, hollow channels running parallel to the packing direction. The channels measured approximately 5.0 × 5.4 Å(2) in the two-dimensional plane perpendicular to the length of the channel, enabling diffusion of oxygen molecules (2.9 × 3.9 Å(2)) through the channel. The powdered LiNc exhibited a single, sharp EPR line under anoxic conditions, with a peak-to-peak linewidth of 630 mG at room temperature. The linewidth was sensitive to surrounding molecular oxygen, showing a linear increase in pO(2) with an oxygen sensitivity of 31.2 mG per mmHg. The LiNc microcrystals can be further prepared as nano-sized crystals without the loss of its high oxygen-sensing properties. The thermal variation of the magnetic properties of LiNc, such as the EPR linewidth, EPR intensity and magnetic susceptibility revealed the existence of two different temperature regimes of magnetic coupling and hence differing columnar packing, both being one-dimensional antiferromagnetic chains but with differing magnitudes of exchange coupling constants. At a temperature of ∼50 K, LiNc crystals undergo a reversible phase transition. The high degree of oxygen-sensitivity of micro- and nano-sized crystals of LiNc, combined with excellent stability, should enable precise and accurate measurements of oxygen concentration in biological systems using EPR spectroscopy.
Collapse
Affiliation(s)
- Ramasamy P. Pandian
- Center for Biomedical EPR Spectroscopy and Imaging, Davis Heart and Lung Research Institute, Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University, Columbus, OH 43210, USA
| | - Michelle Dolgos
- Department of Chemistry, The Ohio State University, Columbus, OH, 43210, USA
| | - Camelia Marginean
- Department of Physics, The Ohio State University, Columbus, OH 43210, USA
| | - Patrick M. Woodward
- Department of Chemistry, The Ohio State University, Columbus, OH, 43210, USA
| | - P. Chris Hammel
- Department of Physics, The Ohio State University, Columbus, OH 43210, USA
| | | | - Periannan Kuppusamy
- Center for Biomedical EPR Spectroscopy and Imaging, Davis Heart and Lung Research Institute, Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University, Columbus, OH 43210, USA
| |
Collapse
|
16
|
Som S, Potter LC, Ahmad R, Vikram DS, Kuppusamy P. EPR oximetry in three spatial dimensions using sparse spin distribution. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2008; 193:210-217. [PMID: 18538600 PMCID: PMC2630719 DOI: 10.1016/j.jmr.2008.05.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2008] [Revised: 05/01/2008] [Accepted: 05/01/2008] [Indexed: 05/26/2023]
Abstract
A method is presented to use continuous wave electron paramagnetic resonance imaging for rapid measurement of oxygen partial pressure in three spatial dimensions. A particulate paramagnetic probe is employed to create a sparse distribution of spins in a volume of interest. Information encoding location and spectral linewidth is collected by varying the spatial orientation and strength of an applied magnetic gradient field. Data processing exploits the spatial sparseness of spins to detect voxels with nonzero spin and to estimate the spectral linewidth for those voxels. The parsimonious representation of spin locations and linewidths permits an order of magnitude reduction in data acquisition time, compared to four-dimensional tomographic reconstruction using traditional spectral-spatial imaging. The proposed oximetry method is experimentally demonstrated for a lithium octa-n-butoxy naphthalocyanine (LiNc-BuO) probe using an L-band EPR spectrometer.
Collapse
Affiliation(s)
- Subhojit Som
- Department of Electrical and Computer Engineering, The Ohio State University, Columbus, OH 43210, USA
| | - Lee C. Potter
- Department of Electrical and Computer Engineering, The Ohio State University, Columbus, OH 43210, USA
| | - Rizwan Ahmad
- Center for Biomedical EPR Spectroscopy and Imaging, Davis Heart and Lung Research Institute, Department of Internal Medicine, The Ohio State University, Columbus, Ohio 43210, USA
| | - Deepti S. Vikram
- Center for Biomedical EPR Spectroscopy and Imaging, Davis Heart and Lung Research Institute, Department of Internal Medicine, The Ohio State University, Columbus, Ohio 43210, USA
| | - Periannan Kuppusamy
- Center for Biomedical EPR Spectroscopy and Imaging, Davis Heart and Lung Research Institute, Department of Internal Medicine, The Ohio State University, Columbus, Ohio 43210, USA
| |
Collapse
|
17
|
Matsumoto S, Espey MG, Utsumi H, Devasahayam N, Matsumoto KI, Matsumoto A, Hirata H, Wink DA, Kuppusamy P, Subramanian S, Mitchell JB, Krishna MC. Dynamic monitoring of localized tumor oxygenation changes using RF pulsed electron paramagnetic resonance in conscious mice. Magn Reson Med 2008; 59:619-25. [PMID: 18224698 DOI: 10.1002/mrm.21500] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Oxygenation status is a key determinant in both tumor growth and responses to therapeutic interventions. The oxygen partial pressure (pO2) was assessed using a novel pulsed electron paramagnetic resonance (EPR) spectroscopy at 750 MHz. Crystals of lithium phthalocyanine (LiPc) implanted into either squamous cell carcinoma (SCC) tumor or femoral muscle on opposing legs of mice were tested by pulsed EPR. The results showed pO2 of SCC tumor was 2.7 +/- 0.4 mmHg, while in the femoral muscle it was 6.1 +/- 0.9 mmHg. A major advantage of pulsed EPR oximetry over conventional continuous-wave (CW) EPR oximetry is the lack of influence from subject motion, while avoiding artifacts associated with modulation or power saturation. Resonators in pulsed EPR are overcoupled to minimize recovery time. This makes changes in coupling associated with object motion minimal without influencing spectral quality. Consequently, pulsed EPR oximetry enables approximately a temporal resolution of approximately one second in pO2 monitoring in conscious subjects, avoiding significant influence of anesthetics on the physiology being studied. The pO2 in SCC tumor and muscle was found to be higher without anesthesia (3.9 +/- 0.5 mmHg for tumor, 8.8 +/- 1.2 mmHg for muscle). These results support the advantage of pulsed EPR in examining pO2 in conscious animals with LiPc chronically implanted in predetermined regions.
Collapse
Affiliation(s)
- Shingo Matsumoto
- Radiation Biology Branch, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, Maryland 20892-1002, USA
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Sostaric JZ, Pandian RP, Bratasz A, Kuppusamy P. Encapsulation of a highly sensitive EPR active oxygen probe into sonochemically prepared microspheres. J Phys Chem B 2007; 111:3298-303. [PMID: 17388464 PMCID: PMC2533636 DOI: 10.1021/jp0682356] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
High-power ultrasound (20 kHz) was used to encapsulate a solution of perchlorotriphenylmethyl triester (PTM-TE, a stable organic free radical) dissolved in hexamethyldisiloxane (HMDS) into a polymerized shell of bovine serum albumin (BSA). The size distribution of the microspheres was between 0.5 and 3 microm with a maximum at approximately 1.2 microm. The electron paramagnetic resonance spectrum of PTM-TE consists of a single, sharp line which is sensitive to the surrounding concentration of oxygen. It was found that the technique of encapsulating a solution of PTM-TE dissolved in HMDS into the BSA microspheres resulted in an overall loss of EPR signal intensity from the washed suspension of microspheres. However, the encapsulated PTM-TE/HMDS solution remained sensitive to the partial pressure of oxygen in the surrounding environment. The microspheres were found to be useful for determining the partial pressure of oxygen in the muscle and tumor tissue of mice.
Collapse
Affiliation(s)
| | | | | | - Periannan Kuppusamy
- Corresponding author. Periannan Kuppusamy, Tel: 614-292-8998; Fax: 614-292-8454; E-mail:
| |
Collapse
|
19
|
Isenberg JS, Hyodo F, Matsumoto KI, Romeo MJ, Abu-Asab M, Tsokos M, Kuppusamy P, Wink DA, Krishna MC, Roberts DD. Thrombospondin-1 limits ischemic tissue survival by inhibiting nitric oxide-mediated vascular smooth muscle relaxation. Blood 2006; 109:1945-52. [PMID: 17082319 PMCID: PMC1801044 DOI: 10.1182/blood-2006-08-041368] [Citation(s) in RCA: 93] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
The nitric oxide (NO)/cGMP pathway, by relaxing vascular smooth muscle cells, is a major physiologic regulator of tissue perfusion. We now identify thrombospondin-1 as a potent antagonist of NO for regulating F-actin assembly and myosin light chain phosphorylation in vascular smooth muscle cells. Thrombospondin-1 prevents NO-mediated relaxation of precontracted vascular smooth muscle cells in a collagen matrix. Functional magnetic resonance imaging demonstrated that an NO-mediated increase in skeletal muscle perfusion was enhanced in thrombospondin-1-null relative to wild-type mice, implicating endogenous thrombospondin-1 as a physiologic antagonist of NO-mediated vasodilation. Using a random myocutaneous flap model for ischemic injury, tissue survival was significantly enhanced in thrombospondin-1-null mice. Improved flap survival correlated with increased recovery of oxygen levels in the ischemic tissue of thrombospondin-1-null mice as measured by electron paramagnetic resonance oximetry. These findings demonstrate an important antagonistic relation between NO/cGMP signaling and thrombospondin-1 in vascular smooth muscle cells to regulate vascular tone and tissue perfusion.
Collapse
Affiliation(s)
- Jeff S Isenberg
- Laboratory of Pathology, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD 20892-1500, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
20
|
|
21
|
Matsumoto A, Matsumoto S, Sowers AL, Koscielniak JW, Trigg NJ, Kuppusamy P, Mitchell JB, Subramanian S, Krishna MC, Matsumoto KI. Absolute oxygen tension (pO(2)) in murine fatty and muscle tissue as determined by EPR. Magn Reson Med 2006; 54:1530-5. [PMID: 16276490 DOI: 10.1002/mrm.20714] [Citation(s) in RCA: 70] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The absolute partial pressure of oxygen (pO(2)) in the mammary gland pad and femoral muscle of female mice was measured using EPR oximetry at 700 MHz. A small quantity of lithium phthalocyanine (LiPc) crystals was implanted in both mammary and femoral muscle tissue of female C3H mice. Subsequent EPR measurements were carried out 1-30 days after implantation with or without control of core body temperature. The pO(2) values in the tissue became stable 2 weeks after implantation of LiPc crystals. The pO(2) level was found to be higher in the femoral muscle than in the mammary tissue. However, the pO(2) values showed a strong dependence on the core body temperature of the mice. The pO(2) values were responsive to carbogen (95% O(2), 5% CO(2)) breathing even 44-58 days after the implantation of LiPc. The LiPc linewidth was also sensitive to changes in the blood supply even 60 days after implantation of the crystals. This study further validates the use of LiPc crystals and EPR oximetry for long-term non-invasive assessment of pO(2) levels in tissues, underscores the importance of maintaining normal body core temperature during the measurements, and demonstrates that mammary tissue functions at a lower pO(2) level than muscle in female C3H mice.
Collapse
Affiliation(s)
- Atsuko Matsumoto
- Radiation Biology Branch, Center for Cancer Research, National Cancer Institute, Bethesda, MD 20892-1002, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
22
|
Diakova G, Bryant RG. The aqueous reference for ESR oximetry. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2006; 178:329-33. [PMID: 16256384 DOI: 10.1016/j.jmr.2005.10.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2005] [Revised: 10/03/2005] [Accepted: 10/06/2005] [Indexed: 05/05/2023]
Abstract
The interaction of molecular oxygen with derivatives of nitroxide EPR spin labels has been investigated using nuclear spin-relaxation spectroscopy in aqueous and nonaqueous solvents. The proton spin-lattice relaxation rate induced by oxygen provides a measure of the local concentration of oxygen, which we find is dependent on solvent. In water, the hydrophobic effect increases the local concentration of oxygen in the nonpolar portions of solute molecules. For nitroxides reduced to the hydroxylamine in aqueous solutions, we find that the local concentration of oxygen is approximately twice that associated with a free diffusion hard sphere limit, while in octane, this effect is absent. These results show that nitroxide based ESR oximetry may suffer a reference concentration shift of order a factor of two if the aqueous nitroxide spectrum or relaxation is used as the reference.
Collapse
Affiliation(s)
- Galina Diakova
- Chemistry Department, University of Virginia, Charlottesville, VA 22901, USA
| | | |
Collapse
|
23
|
Sakata YS, Grinberg OY, Grinberg S, Springett R, Swartz HM. Simultaneous NIR-EPR spectroscopy of rat brain oxygenation. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2005; 566:357-62. [PMID: 16594173 DOI: 10.1007/0-387-26206-7_47] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Changes in cerebral oxygenation were simultaneously monitored by electric paramagnetic resonance (EPR) oximetry and near-infrared spectroscopy (NIRS). The tissue oxygen tension (t-pO2) was measured with an L-band (1.2 GHz) EPR spectrometer with an external loop resonator and the concentration of oxyhemoglobin [HbO2] and deoxyhemoglobin [Hb] were measured with a full-spectral NIRS system. Mean cerebral hemoglobin saturation (SmcO2) was calculated from the absolute [HbO2] and [Hb]. Six adult male rats were implanted with lithium phthalocyanine (LiPc) crystals into the left cerebral cortex. The change in oxygenation of the brain was induced by altering the inspired oxygen fraction (FiO2) in air from 0.30 at baseline to 0.0, 0.05, 0.10, and 0.15 for 1, 2, 5, and 5 minutes, respectively, followed by reoxygenation with an FiO2 = 0.30. Although both t-pO2 and SmcO2 values showed a decrease during reduced FiO2 followed by recovery on reoxygenation, it was found that SmcO2 recovered more rapidly than t-PO2 during the recovery phase. The recovery of t-pO2 is not only related to blood oxygenation, but also to delivery, consumption, and diffusion of oxygen into the tissue from the vascular system. Further studies will be required to determine the exact mechanisms for the delay between the recovery of SmcO2 and t-pO2.
Collapse
|
24
|
Ilangovan G, Zweier JL, Kuppusamy P. Mechanism of oxygen-induced EPR line broadening in lithium phthalocyanine microcrystals. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2004; 170:42-48. [PMID: 15324756 DOI: 10.1016/j.jmr.2004.05.018] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2004] [Revised: 05/17/2004] [Indexed: 05/24/2023]
Abstract
EPR oximetry has been recognized as an important tool for determining oxygen concentration in biological tissues, in vivo. The method relies on the use of oxygen-sensitive paramagnetic probes whose linewidth varies predictably, mostly linear, with oxygen concentration. Lithium phthalocyanine (LiPc) radical has emerged as the probe of choice due to its superior EPR sensitivity, oxygen response, and biocompatibility. However, there are certain limitations in the preparation of this material in a pure and usable form. In our efforts to improve the synthesis of this material for reliable use in oximetry applications, we developed microcrystalline particulates that showed several advantages over other probes. Despite its advantages, the probe shows linear response to pO2 only in the range of 0-70 mmHg, beyond which a saturation behavior is observed. The goal of this study was to understand the mechanism of the interaction of oxygen with LiPc in order to interpret the experimentally observed linewidths. We propose a dual-spin model in which the freely diffusing spins of LiPc are converted to fixed spins by adsorption of molecular oxygen. The proposed mechanism was verified from the effect of oxygenation/deoxygenation processes on the linewidth of LiPc. In summary, we demonstrated that adsorption of oxygen molecules on LiPc contributes to a nonlinear line-broadening effect. This understanding is important for the future design of new EPR oximetry probes.
Collapse
Affiliation(s)
- Govindasamy Ilangovan
- Center for Biomedical EPR Spectroscopy and Imaging, Davis Heart and Lung Research Institute, The Ohio State University, 420 West 12th Avenue, Columbus, OH 43210, USA
| | | | | |
Collapse
|
25
|
Pandian RP, Parinandi NL, Ilangovan G, Zweier JL, Kuppusamy P. Novel particulate spin probe for targeted determination of oxygen in cells and tissues. Free Radic Biol Med 2003; 35:1138-48. [PMID: 14572616 DOI: 10.1016/s0891-5849(03)00496-9] [Citation(s) in RCA: 132] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
The synthesis and characterization of a new lithium octa-n-butoxy-substituted naphthalocyanine radical probe (LiNc-BuO) and its use in the determination of concentration of oxygen (oximetry) by electron paramagnetic resonance (EPR) spectroscopy are reported. The probe is synthesized as a needle-shaped microcrystalline particulate. The particulate shows a single-line EPR spectrum that is highly exchange-narrowed with a line-width of 210 mG. The EPR line-width is sensitive to molecular oxygen showing a linear relationship between the line-width and concentration of oxygen (pO(2)) with a sensitivity of 8.5 mG/mmHg. We studied a variety of physicochemical and biological properties of LiNc-BuO particulates to evaluate the suitability of the probe for in vivo oximetry. The probe is unaffected by biological oxidoreductants, stable in tissues for several months, and can be successfully internalized in cells. We used this probe to monitor changes in concentration of oxygen in the normal muscle and RIF-1 tumor tissue of mice as a function of tumor growth. The data showed a rapid decrease in the tumor pO(2) with increase of tumor volume. Human arterial smooth muscle cells, upon internalization of the LiNc-BuO probe, showed a marked oxygen gradient across the cell membrane. In summary, the newly synthesized octa-n-butoxy derivative of lithium naphthalocyanine has unique properties that are useful for determining oxygen concentration in chemical and biological systems by EPR spectroscopy and also for magnetic tagging of cells.
Collapse
Affiliation(s)
- Ramasamy P Pandian
- Center for Biomedical EPR Spectroscopy and Imaging, Department of Internal Medicine, Davis Heart and Lung Research Institute, The Ohio State University, Columbus, OH 43210, USA
| | | | | | | | | |
Collapse
|
26
|
Ilangovan G, Pal R, Zweier JL, Kuppusamy P. Electrochemical Preparation and EPR Studies of Lithium Phthalocyanine. 4. Effect of Nitric Oxide. J Phys Chem B 2002. [DOI: 10.1021/jp026360l] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Govindasamy Ilangovan
- Biomedical EPR Imaging Center, Dorothy M. Davis Heart & Lung Research Institute, The Ohio State University, 420 West 12th Avenue, Columbus, Ohio 43210
| | - Ranjeeta Pal
- Biomedical EPR Imaging Center, Dorothy M. Davis Heart & Lung Research Institute, The Ohio State University, 420 West 12th Avenue, Columbus, Ohio 43210
| | - Jay L. Zweier
- Biomedical EPR Imaging Center, Dorothy M. Davis Heart & Lung Research Institute, The Ohio State University, 420 West 12th Avenue, Columbus, Ohio 43210
| | - Periannan Kuppusamy
- Biomedical EPR Imaging Center, Dorothy M. Davis Heart & Lung Research Institute, The Ohio State University, 420 West 12th Avenue, Columbus, Ohio 43210
| |
Collapse
|
27
|
Ilangovan G, Li H, Zweier JL, Kuppusamy P. Electrochemical Preparation and EPR Studies of Lithium Phthalocyanine. 3. Measurements of Oxygen Concentration in Tissues and Biochemical Reactions. J Phys Chem B 2001. [DOI: 10.1021/jp010130+] [Citation(s) in RCA: 43] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
28
|
Panagiotelis I, Nicholson I, Hutchison JM. Electron spin relaxation time measurements using radiofrequency longitudinally detected ESR and application in oximetry. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2001; 149:74-84. [PMID: 11273754 DOI: 10.1006/jmre.2000.2282] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Longitudinally detected ESR (LODESR) involves transverse ESR irradiation with a modulated source and observing oscillations in the spin magnetization parallel to the main magnetic field. In this study, radiofrequency-LODESR was used for oximetry by measuring the relaxation times of the electron. T1e and T2e were measured by investigating LODESR signal magnitude as a function of detection frequency. We have also predicted theoretically and verified experimentally the LODESR signal phase dependence on detection frequency and relaxation times. These methods are valid even for inhomogeneous lines provided that T1e>>T2e. We have also developed a new method for measuring T1e, valid for inhomogeneous spectra, for all values of T1e and T2e, based on measuring the spectral area as a function of detection frequency. We have measured T1e and T2e for lithium phthalocyanine crystals, for the nitroxide TEMPOL, and for the single line agent Triarylmethyl (TAM). Furthermore, we have collected spectra from aqueous solutions of TEMPOL and TAM at different oxygen concentrations and confirmed that T1e values are reduced with increased oxygen concentration. We have also measured the spin-lattice electronic relaxation time for degassed aqueous solutions of the same agents at different agent concentrations. T1e decreases as a function of concentration for TAM while it remains independent of free radical concentration for TEMPOL, a major advantage for oxygen mapping. This method, combined with the ability of LODESR to provide images of exogenous free radicals in vivo, presents an attractive alternative to the conventional transverse ESR linewidth based oximetry methods.
Collapse
Affiliation(s)
- I Panagiotelis
- Department of Biomedical Physics and Bio-Engineering, University of Aberdeen, Foresterhill, Aberdeen, AB25 2ZD, United Kingdom
| | | | | |
Collapse
|
29
|
Ilangovan G, Zweier JL, Kuppusamy P. Electrochemical Preparation and EPR Studies of Lithium Phthalocyanine. Part 2: Particle-Size-Dependent Line Broadening by Molecular Oxygen and Its Implications as an Oximetry Probe. J Phys Chem B 2000. [DOI: 10.1021/jp0013863] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Govindasamy Ilangovan
- The EPR Center and Division of Cardiology, Department of Medicine, Johns Hopkins University, School of Medicine, 5501 Hopkins Bayview Circle, Baltimore, Maryland 21224
| | - Jay L. Zweier
- The EPR Center and Division of Cardiology, Department of Medicine, Johns Hopkins University, School of Medicine, 5501 Hopkins Bayview Circle, Baltimore, Maryland 21224
| | - Periannan Kuppusamy
- The EPR Center and Division of Cardiology, Department of Medicine, Johns Hopkins University, School of Medicine, 5501 Hopkins Bayview Circle, Baltimore, Maryland 21224
| |
Collapse
|
30
|
Ilangovan G, Zweier JL, Kuppusamy P. Electrochemical Preparation and EPR Studies of Lithium Phthalocyanine: Evaluation of the Nucleation and Growth Mechanism and Evidence for Potential-Dependent Phase Formation. J Phys Chem B 2000. [DOI: 10.1021/jp9935182] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Govindasamy Ilangovan
- The EPR Center and Division of Cardiology, Department of Medicine, Johns Hopkins University School of Medicine, 5501 Hopkins Bayview Circle, Baltimore, Maryland 21224
| | - Jay L. Zweier
- The EPR Center and Division of Cardiology, Department of Medicine, Johns Hopkins University School of Medicine, 5501 Hopkins Bayview Circle, Baltimore, Maryland 21224
| | - Periannan Kuppusamy
- The EPR Center and Division of Cardiology, Department of Medicine, Johns Hopkins University School of Medicine, 5501 Hopkins Bayview Circle, Baltimore, Maryland 21224
| |
Collapse
|