1
|
Al Kindi AH, Mandisha AF, Hammam M, Salem A. Redo mitral valve replacement using valve-on-valve technique in a patient with severe posterior mitral annular calcification. BMJ Case Rep 2021; 14:14/7/e243527. [PMID: 34290026 DOI: 10.1136/bcr-2021-243527] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Redo mitral valve replacement surgery due to bioprosthetic valve failure can carry serious surgical challenges. In addition to the usual redo sternotomy risk, there is risk of circumflex coronary artery injury or atrioventricular disruption from explanting the prosthesis. Alternatives to prosthesis explantation may be needed in some cases.We report a case of mitral bioprosthetic valve failure in a young patient who had a history of atrioventricular disruption during the first surgery and had pericardial patch repair of the defect. The risk of explanting the bioprosthesis during redo surgery was very high. Therefore, we performed valve replacement using valve-on-valve technique in which the new valve is implanted within the sewing ring of the previous bioprosthesis without explanting the valve. This technique converted a very highly futile surgery to a conventional redo surgery risk. The patient had a successful surgery with no intraoperative or postoperative complications.
Collapse
Affiliation(s)
- Adil H Al Kindi
- Cardiothoracic Surgery, Sultan Qaboos University Hospital, Al Khod, Oman
| | | | - Mohamed Hammam
- Cardiothoracic Surgery, Sultan Qaboos University Hospital, Al Khod, Oman
| | - AbdelMaged Salem
- Cardiothoracic Surgery, Sultan Qaboos University Hospital, Al Khod, Oman
| |
Collapse
|
2
|
Aoyagi S, Tomoeda H, Kawano H, Yokose S, Fukunaga S. Doppler Echocardiographic Evaluation of Prosthetic Valves in Tricuspid Position. Asian Cardiovasc Thorac Ann 2016; 11:193-7. [PMID: 14514546 DOI: 10.1177/021849230301100302] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Doppler echocardiographic characteristics of 29 normally functioning prosthetic valves (23 mechanical, 6 biological) and 8 obstructed mechanical prostheses in the tricuspid position are reported. In normally functioning prostheses, peak velocity, mean pressure gradient, and pressure-half time were 1.25 ± 0.18 m·sec−1, 2.6 ± 1.1 mm Hg, and 122.6 ± 30.7 msec, respectively. Although no significant differences were seen in peak velocity and mean pressure gradient between mechanical and biological valves, the pressure half-time was significantly greater in biological valves. All normally functioning prostheses had a mean pressure gradient ⩽5.5 mm Hg and pressure half-time < 200 msec. In obstructed bileaflet valves, peak velocity was 1.66 ± 0.28 m·sec−1, mean pressure gradient was 6.1 ± 2.8 mm Hg, and pressure half-time was 265.8 ± 171.7 msec. These Doppler data were significantly greater than those in normally functioning valves where the mean pressure gradient was ⩽5.1 mm Hg and the pressure half-time was ⩽156 msec in all except one patient. Pathological obstruction of a tricuspid prosthesis can be strongly suspected in patients with a mean pressure gradient > 5.5 mm Hg and a pressure half-time > 200 msec on Doppler echocardiography.
Collapse
Affiliation(s)
- Shigeaki Aoyagi
- Department of Surgery, Kurume University School of Medicine, Kurume, Japan.
| | | | | | | | | |
Collapse
|
3
|
Valvular performance and aortic regurgitation following transcatheter aortic valve replacement using Edwards valve versus CoreValve for severe aortic stenosis: A Meta-analysis. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2016; 17:248-55. [DOI: 10.1016/j.carrev.2016.02.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2015] [Revised: 02/07/2016] [Accepted: 02/09/2016] [Indexed: 11/20/2022]
|
4
|
Bogunovic N, Horstkotte D, Faber L, Bogunovic L, van Buuren F. Echocardiographically derived effective valve opening area in mitral prostheses: a comparative analysis of various calculations using continuity equation and pressure half time method. Heart Vessels 2015; 31:932-8. [PMID: 26049365 DOI: 10.1007/s00380-015-0690-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2014] [Accepted: 05/01/2015] [Indexed: 10/23/2022]
Abstract
Detection of dysfunctional mitral valve prostheses (MP) remains complex even though being optimized by considering echocardiographically derived prosthetic effective orifice area (VA). The purpose was to compare VA in MP, calculated by the continuity equation (CE) using peak velocities (CEVpeak), mean velocities (CEVmean), velocity-time integrals (CEVTI) and the pressure half time method using 220 ms as constant first (PHT220) as well as optimized constants. In 267 consecutive patients with normally functioning MP, we investigated VA within the first postoperative month. With increasing prosthetic sizes, mean VA values also increase in all calculations. The statistical curves demonstrate no significant difference in graphical steepness but show different levels. Comparison of mean VA showed the known systematic higher values of PHT220 and significantly decreased results when using CEVTI. This systematic difference between mean VA applying PHT220 versus CEVTI is approximately 1.0 cm(2) for all prosthetic sizes. Calculations via CEVpeak were close to the results of CEVTI. CEVmean produced values, which graphically correspond to the PHT220 curve. Only PHT220 detected the constructional equal prosthetic inner ring width between 29 and 31 mm. To compensate the systematic difference between CEVTI and PHT220, an optimized constant of 140 ms was calculated to be applied in PHT (PHT140). VA is a robust and, therefore, preferable parameter for investigating MP. If needed, both CE and PHT are applicable with a systematical difference between CEVTI and PHT220. An optimized constant of 140 ms (PHT140) should be applied when calculating VA of mitral valve prostheses via PHT.
Collapse
Affiliation(s)
- Nikola Bogunovic
- Department of Cardiology, Heart and Diabetes Centre North Rhine-Westphalia, Ruhr University Bochum, Georgstr. 11, 32545, Bad Oeynhausen, Germany.
| | - Dieter Horstkotte
- Department of Cardiology, Heart and Diabetes Centre North Rhine-Westphalia, Ruhr University Bochum, Georgstr. 11, 32545, Bad Oeynhausen, Germany
| | - Lothar Faber
- Department of Cardiology, Heart and Diabetes Centre North Rhine-Westphalia, Ruhr University Bochum, Georgstr. 11, 32545, Bad Oeynhausen, Germany
| | - Lukas Bogunovic
- Department of Physics, University of Bielefeld, Bielefeld, Germany
| | - Frank van Buuren
- Department of Cardiology, Heart and Diabetes Centre North Rhine-Westphalia, Ruhr University Bochum, Georgstr. 11, 32545, Bad Oeynhausen, Germany
| |
Collapse
|
5
|
Malhotra A, Pawar SR, Srivastava A, Yadav BS, Kaushal R, Sharma P, Songra M. Clinical and hemodynamic study of tilting disc heart valve: Single-center study. Asian Cardiovasc Thorac Ann 2014; 22:519-25. [PMID: 24646514 DOI: 10.1177/0218492313475640] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND The TTK Chitra heart valve has been developed and widely used in India. This study aimed to evaluate its hemodynamics, complications, and event-free survival in comparison with other commonly used prosthetic valves. The role of color Doppler echocardiography in the follow-up of patients with prosthetic valves was also studied. PATIENTS AND METHODS Two hundred patients underwent 249 valve replacements (122 mitral, 29 aortic, 49 both). Total follow-up was 451 patient-years. RESULTS There were 18 late deaths (3.98% ± 0.92% per patient-year). One mitral valve replacement patient (0.36% ± 0.36% per patient-year) developed valve thrombosis. Two aortic valve replacement patients (2.74% ± 1.91% per patient-year), 2 double-valve replacement patients (1.95% ± 1.36% per patient-year) and 3 mitral valve replacement patients (1.08% ± 0.62% per patient-year) developed embolic complications. Freedom from all valve related mortality and morbidity at 4 years was 86% ± 4% for mitral valve replacement, 56% ± 10% for double-valve replacement, and 89% ± 6% for aortic valve replacement. The average peak gradient, mean gradient, and average peak velocity for the aortic and mitral positions were found to be comparable to those of other commonly used valves. CONCLUSION The performance of this valve in terms of hemodynamic complications, mortality, and morbidity is comparable to other valves in common use. Hemodynamic gradients are more reproducible than effective orifice area, hence more beneficial for follow-up.
Collapse
|
6
|
Spethmann S, Dreger H, Schattke S, Baldenhofer G, Saghabalyan D, Stangl V, Laule M, Baumann G, Stangl K, Knebel F. Doppler haemodynamics and effective orifice areas of Edwards SAPIEN and CoreValve transcatheter aortic valves. Eur Heart J Cardiovasc Imaging 2012; 13:690-6. [PMID: 22307868 DOI: 10.1093/ehjci/jes021] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
AIMS Transcatheter aortic valve implantation (TAVI) is a new therapy for severe aortic stenosis in high-risk patients. So far, no reference values for the echocardiographic assessment of this new class of heart valves have been established. The aim of our study was to determine Doppler haemodynamics and the effective orifice area (EOA). METHODS AND RESULTS We retrospectively analysed the earliest transthoracic echocardiographic examinations of 146 stable patients after successful TAVI (median 8±20 days). Doppler examinations were analysed for peak instantaneous velocity, peak, and the mean systolic gradient. EOA was determined using the continuity equation. Patients with severe paravalvular aortic or mitral valve regurgitation were excluded. The overall peak instantaneous velocity (n=146) was 2.0±0.4 m/s with a peak systolic gradient of 17.1±7.4 mmHg and a mean gradient of 9.3±4.5 mmHg. The mean EOA was 1.82±0.43 cm2 with an indexed EOA of 1.0±0.27 cm2/m2. In general, all prostheses showed similar values-with the exception of the Edwards Sapien 23 mm which was associated with higher velocities and peak pressure gradients. CONCLUSION Our study establishes the normal range for Doppler haemodynamics of four transcatheter aortic valve prostheses. Compared with previously published data of surgically implanted bioprostheses percutaneous valves tend to have similar EOA values but lower mean peak velocities and pressure gradients. In comparison with physiological haemodynamics; however, this new class of heart valves is still associated with a mild obstruction.
Collapse
Affiliation(s)
- Sebastian Spethmann
- Charité Campus Mitte, Universitätsmedizin, Charitéplatz 1, D-10117 Berlin, Germany.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
7
|
|
8
|
Nellessen U, Inselmann G, Ludwig J, Jahns R, Capell AJ, Eigel P. Rest and exercise hemodynamics before and after valve replacement--a combined Doppler/catheter study. Clin Cardiol 2009; 23:32-8. [PMID: 10680027 PMCID: PMC6655087 DOI: 10.1002/clc.4960230107] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Hemodynamic improvement is a common finding following valve replacement. However, despite a normally functioning prosthesis and normal left ventricular ejection fraction, some patients may show an abnormal hemodynamic response to exercise. METHODS In a combined catheter/Doppler study, rest and exercise hemodynamics were evaluated in 23 patients following aortic (n = 12) (Group 1) or mitral valve (n = 11) (Group 2) replacement and compared with preoperative findings. Patient selection was based on absence of coronary artery disease and left ventricular failure as shown by preoperative angiography. Cardiac output, pulmonary artery pressure, pulmonary capillary pressure, and pulmonary resistance were measured by right heart catheterization, whereas the gradient across the valve prosthesis was determined by Doppler echocardiography. Postoperative evaluation was done at rest and during exercise. The mean follow-up was 8.2 +/- 2.2 years in Group 1 and 4.2 +/- 1 years in Group 2. RESULTS With exercise, there was a significant rise in cardiac output in both groups. In Group 1, mean pulmonary pressure/capillary pressure decreased from 24 +/- 9/18 +/- 9 mmHg preoperatively to 18 +/- 2/12 +/- 4 mmHg postoperatively (p < 0.05), and increased to 43 +/- 12/30 +/- 8 mmHg with exercise (p < 0.05). The corresponding values for Group 2 were 36 +/- 12/24 +/- 6 mmHg preoperatively, 24 +/- 7/17 +/- 6 mmHg postoperatively (p < 0.05), and 51 +/- 2/38 +/- 4 mmHg with exercise (p < 0.05). Pulmonary vascular resistance was 109 +/- 56 dyne.s.cm-5 preoperatively, 70 +/- 39 dyne.s.cm-5 postoperatively (p < 0.05), and 70 +/- 36 dyne.s.cm-5 with exercise in Group 1. The corresponding values for Group 2 were 241 +/- 155 dyne.s.cm-5, 116 +/- 39 dyne.s.cm-5 (p < 0.05), and 104 +/- 47 dyne.s.cm-5. There was a significant increase in the gradients across the valve prosthesis in both groups, showing a significant correlation between the gradient at rest and exercise. No correlation was found between valve prosthesis gradient and pulmonary pressures. CONCLUSION Exercise-induced pulmonary hypertension and abnormal left ventricular filling pressures seem to be a frequent finding following aortic or mitral valve replacement. Both hemodynamic abnormalities seem not to be determined by obstruction to flow across the valve prosthesis and may be concealed, showing nearly normal values at rest but a pathologic response to physical stress.
Collapse
Affiliation(s)
- U Nellessen
- Johanniter-Krankenhaus der Altmark, Stendal gGmbH, Medizinische Klinik II, Germany
| | | | | | | | | | | |
Collapse
|
9
|
Sadeghpour A, Saadatifar H, Kiavar M, Esmaeilzadeh M, Maleki M, Ojaghi Z, Noohi F, Samiei N, Mohebbi A. Doppler Echocardiographic Assessment of Pulmonary Prostheses: A Comprehensive Assessment Including Velocity Time Integral Ratio and Prosthesis Effective Orifice Area. CONGENIT HEART DIS 2008; 3:415-21. [DOI: 10.1111/j.1747-0803.2008.00223.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
10
|
Jayawardena S, Sooriabalan D, Burzyantseva O, Sinnapunayagm S. Paravalvular mitral valve leakage presenting as congestive heart failure, missed by TTE but diagnosed by TEE: a case report. CASES JOURNAL 2008; 1:216. [PMID: 18838002 PMCID: PMC2569914 DOI: 10.1186/1757-1626-1-216] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/13/2008] [Accepted: 10/06/2008] [Indexed: 11/10/2022]
Abstract
BACKGROUND Diagnosis of prosthetic valve leakage by the transthoracic echocardiogram (TTE) technique is more difficult. These limitations are diminished with the use of transesophageal echocardiogram (TEE) techniques. CASE REPORT A 71 year old Caucasian male presented with symptoms and signs of congestive heart failure. Past medical history included a bio-prosthetic mitral valve replacement for severe mitral regurgitation. TTE showed possible mitral regurgitation. As the TTE did not correlate with the finding of a high E-velocity, a TEE was performed, which showed a significant paravalvular leak of moderate severity around the bio-prosthetic mitral valve. CONCLUSION There should be a high degree of suspicion to diagnose a paravalvular leak.
Collapse
|
11
|
Bhindi R, Bull S, Schrale RG, Wilson N, Ormerod OJ. Surgery Insight: percutaneous treatment of prosthetic paravalvular leaks. ACTA ACUST UNITED AC 2008; 5:140-7. [DOI: 10.1038/ncpcardio1112] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2007] [Accepted: 11/29/2007] [Indexed: 11/09/2022]
|
12
|
Aslam AK, Aslam AF, Vasavada BC, Khan IA. Prosthetic heart valves: Types and echocardiographic evaluation. Int J Cardiol 2007; 122:99-110. [PMID: 17434628 DOI: 10.1016/j.ijcard.2006.12.037] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/26/2006] [Revised: 12/15/2006] [Accepted: 12/30/2006] [Indexed: 11/30/2022]
Abstract
In the last five decades multiple different models of prosthetic valves have been developed. The purpose of this article is to provide a comprehensive source of information for the types and the echocardiographic evaluation of the prosthetic heart valves.
Collapse
Affiliation(s)
- Ahmad Kamal Aslam
- Division of Cardiology, Beth Israel Medical Center, 16th Street 1st Avenue, New York, NY 10003, USA.
| | | | | | | |
Collapse
|
13
|
Gottdiener JS, Bednarz J, Devereux R, Gardin J, Klein A, Manning WJ, Morehead A, Kitzman D, Oh J, Quinones M, Schiller NB, Stein JH, Weissman NJ. American Society of Echocardiography recommendations for use of echocardiography in clinical trials. J Am Soc Echocardiogr 2005; 17:1086-119. [PMID: 15452478 DOI: 10.1016/j.echo.2004.07.013] [Citation(s) in RCA: 329] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
|
14
|
Kumar P, Dalvi B, Chikkatur R, Kandhachar P, Parida R, Ahuja V, Jadhav UE, Tendolkar A. TTK Chitra tilting disc valve: Hemodynamic evaluation. Indian J Thorac Cardiovasc Surg 2004. [DOI: 10.1007/s12055-004-0060-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
|
15
|
Tong AT, Roudaut R, Ozkan M, Sagie A, Shahid MSA, Pontes Júnior SC, Carreras F, Girard SE, Arnaout S, Stainback RF, Thadhani R, Zoghbi WA. Transesophageal echocardiography improves risk assessment of thrombolysis of prosthetic valve thrombosis: results of the international PRO-TEE registry. J Am Coll Cardiol 2004; 43:77-84. [PMID: 14715187 DOI: 10.1016/j.jacc.2003.08.028] [Citation(s) in RCA: 149] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
OBJECTIVES The goal of this study was to evaluate whether quantitation of thrombus burden with transesophageal echocardiography (TEE) can help risk-stratify patients undergoing thrombolysis of prosthetic valve thrombosis (PVT). BACKGROUND Thrombolytic therapy of PVT has an unpredictable risk of embolization and complications. METHODS An international registry of patients with suspected PVT undergoing two-dimensional/Doppler and TEE before thrombolysis was established. All TEE studies were reviewed and quantitated by a single observer blinded to all data. RESULTS From 1985 to 2001, 107 patients (71 females; age 24 to 86 years) from 14 centers (6 in the U.S.) were identified. The majority of cases involved the mitral valve (79 mitral, 13 aortic, and 15 tricuspid). Hemodynamic success rate was achieved in 85% and was similar across valves. Overall complications were observed in 17.8%, and death in 5.6%. Predictors of complications were: New York Heart Association (NYHA) functional class, presence of shock, sinus tachycardia, hypotension, previous history of stroke, thrombus extension beyond the valve ring, and thrombus area. Multivariate analysis demonstrated that two variables were independent predictors of complications: thrombus area by TEE (odds ratio [OR] 2.41 per 1 cm2 increment, 95% confidence interval [CI] 1.12 to 5.19) and prior history of stroke (OR 4.55, 95% CI 1.35 to 15.38). A thrombus area <0.8 cm2 identified patients at lower risk for complications from thrombolysis, irrespective of NYHA functional class. CONCLUSIONS In PVT, the thrombus size imaged with TEE is a significant independent predictor of outcome. Transesophageal echocardiography can identify low-risk groups for thrombolysis irrespective of symptom severity and is therefore recommended in the management of prosthetic valve thrombosis.
Collapse
Affiliation(s)
- Ann T Tong
- Baylor College of Medicine, Houston, Texas, USA
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Pehrsson SK, Eriksson MJ, Lentell JC, Bowald S. Early results of a new mechanical tri-leaflet heart valve prosthesis--"Tricusp": an animal study. SCAND CARDIOVASC J 2003; 37:235-9. [PMID: 12944213 DOI: 10.1080/14017430310001681] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
OBJECTIVE A new tri-leaflet mechanical heart valve made of titanium was inserted in the mitral position to evaluate early results. METHODS AND RESULTS Five sheep were followed between 3 and 6 months (mean 4.7 months) and performed very well clinically during the follow-up period. In three of five animals a minor para-valvular leakage without hemodynamic importance was observed. The invasive pressure measurements at the end of follow-up revealed only minor transvalvular pressure differences between 1 and 4 mmHg (mean 2.4 mmHg). Similar results were obtained by echo-Doppler technique. Histological examination of the tissue around the valve showed no signs of foreign body reaction or chronic inflammatory reaction. CONCLUSION This new tri-leaflet heart valve has shown an excellent hemodynamic performance and good tissue compatibility, and therefore may be an alternative to other currently used valve prostheses.
Collapse
|
17
|
Chambers JB, Oo L, Narracott A, Lawford PM, Blauth CI. Nominal size in six bileaflet mechanical aortic valves: a comparison of orifice size and biologic equivalence. J Thorac Cardiovasc Surg 2003; 125:1388-93. [PMID: 12830058 DOI: 10.1016/s0022-5223(03)00039-4] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
OBJECTIVES Nominal size remains the standard by which valves are compared, but its relationship with orifice area and the patient tissue annulus diameter may differ according to valve design. The aims of this study were to measure the orifice size and compare biologic equivalence in six bileaflet mechanical heart valve designs. METHODS The inflow aspect of each of 29 valves was photographed then digitized, and the maximum internal diameter and orifice area were calculated. Biologic equivalence was assessed with a series of machined polypropylene blocks. RESULTS The orifice area ranged between 159 and 222 mm(2) for the six size 19 valves. The internal diameter ranged from 1.6 to 4.6 mm less than the manufacturer's nominal size. Biologic equivalence assessed from an estimate of tissue annulus diameter with machined blocks ranged from 1.0 and 3.5 mm larger than nominal size for the intra-annular valves. This diameter ranged from 3.5 mm smaller to 1.5 mm larger than nominal size for the supra-annular valves. CONCLUSION There are major differences between nominal size and biologic equivalence. This may lead to confusion when attempting to make comparisons between different valve designs with the same nominal size. A clearer sizing nomenclature is required and could be based on in vitro assessment of tissue annulus diameter or an alphanumeric code.
Collapse
Affiliation(s)
- John B Chambers
- Cardiothoracic Centre, Guy's and St Thomas' Hospitals, London, United Kingdom.
| | | | | | | | | |
Collapse
|
18
|
Emery RW, Van Nooten GJ, Tesar PJ. The initial experience with the ATS Medical mechanical cardiac valve prosthesis. Ann Thorac Surg 2003; 75:444-52. [PMID: 12607652 DOI: 10.1016/s0003-4975(02)04537-x] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND From May 1994 through October 2000, a total of 1,146 patients underwent valve replacement with the ATS Medical mechanical cardiac valve prosthesis under a study protocol approved by international ethics committees (non-United States participants) or under a United States Food and Drug Administration-approved Investigational Device Exemption study. The study took place at 19 domestic and three international centers. METHODS As required by the Food and Drug Administration's Heart Valve Guidance Document, only isolated implants were included in the study (double-valve implants were excluded), with operative and follow-up data collected from each center. RESULTS Aortic valve replacement (AVR) was conducted in 801 patients (309 with coronary bypass) and mitral valve replacement (MVR) in 345 patients (78 with coronary bypass). Overall operative (< or = 30 days post implant) mortality was 2.1% (17 AVR = 2.1%, 7 MVR = 2.0%), 7 of which (AVR = 4, MVR = 3) were valve related. In 2,086 patient-years (1,459 AVR patient-years, 627 MVR patient-years) of follow-up, there were an additional 50 patient deaths of these, 18 were valve related, 9 due to anticoagulant related bleeding, 5 sudden/unexplained, and 1 each after stroke, thrombosis, prosthetic valve endocarditis, and thromboembolism. Late (>30 days post implant) valve-related complications included: transient and chronic thromboembolism (27 AVR (linearized rate 1.85%/patient-year) and 20 MVR (3.19%/patient-year), of which 11/47 (0.53%/patient-year) had chronic deficits, thrombosis (1 AVR = 0.07%/patient-year and 4 MVR = 0.64%/patient-year), paravalvular leak (10 AVR = 0.69%/patient-year and 8 MVR = 1.28%/patient-year), anticoagulant related hemorrhage (34 AVR = 2.33%/patient-year and 8 MVR = 1.28%/patient-year), prosthetic valve endocarditis (3 AVR = 0.21%/patient-year and 2 MVR = 0.32%/patient-year), and structural valve failure or dysfunction (0%). Echocardiographic gradients were proportional to valve size and did not significantly change over the follow-up period. CONCLUSIONS This study documented the ATS Medical mechanical cardiac valve prosthesis to be a valuable addition to the surgeon's armamentarium in the treatment of cardiac valvular disease.
Collapse
Affiliation(s)
- Robert W Emery
- Cardiac Surgical Associates, Minneapolis, Minnesota, USA.
| | | | | |
Collapse
|
19
|
Fernandes V, Olmos L, Nagueh SF, Quiñones MA, Zoghbi WA. Peak early diastolic velocity rather than pressure half-time is the best index of mechanical prosthetic mitral valve function. Am J Cardiol 2002; 89:704-10. [PMID: 11897213 DOI: 10.1016/s0002-9149(01)02343-8] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Reliable screening of mechanical prosthetic mitral valve (PMV) dysfunction by transthoracic echocardiography (TTE) is mandatory because transesophageal echocardiography (TEE) cannot be routinely used. However, acoustic shadowing seriously hampers detection of PMV dysfunction with TTE, particularly regurgitation. To identify TTE indexes that can detect PMV dysfunction (regurgitation or obstruction), 134 patients (age 60 +/- 12 years, 64 men) with PMV who underwent TTE and TEE within 3 +/- 5 days were assessed. There were 73 normal and 61 dysfunctional valves (40 regurgitant, 21 obstructive). By multivariate analysis, peak E velocity was the best predictor of a dysfunctional valve. Both peak E velocity (E > or =1.9 m/s; sensitivity 92%, specificity 78%) and the ratio of velocity-time integrals of flow through the prosthesis to that of the left ventricular outflow (VTI(pmv/)VTI(lvo) > or =2.2; sensitivity 91%, specificity 74%) were successful in detecting PMV dysfunction. Although pressure half-time (PHT) readily identified PMV obstruction, it did not detect regurgitation. Logistic models including peak E velocity and VTI(pmv)/VTI(lvo) or PHT were equally successful in detecting PMV dysfunction. However, all 3 variables were needed to best distinguish among normal, obstructed, and regurgitant valves. A peak E velocity > or =1.9 m/s and VTI(pmv)/VTI(lvo) ratio > or =2.2 predicted valve regurgitation in 83% of valves when PHT was < 130 ms, and valve stenosis in 95% when PHT was >130 ms. Importantly, a peak E velocity < 1.9 m/s, VTI(pmv)/VTI(lvo) ratio < 2.2, and a PHT < 130 ms had a predictive accuracy for a normal valve of 98%. Thus, TTE Doppler indexes can be used as screening parameters of PMV dysfunction and help select patients for further diagnostic evaluation with TEE.
Collapse
Affiliation(s)
- Valerian Fernandes
- Section of Cardiology, Department of Medicine, Baylor College of Medicine, and The DeBakey Heart Center, Houston, Texas 77030, USA
| | | | | | | | | |
Collapse
|
20
|
Quiñones MA, Otto CM, Stoddard M, Waggoner A, Zoghbi WA. Recommendations for quantification of Doppler echocardiography: a report from the Doppler Quantification Task Force of the Nomenclature and Standards Committee of the American Society of Echocardiography. J Am Soc Echocardiogr 2002; 15:167-84. [PMID: 11836492 DOI: 10.1067/mje.2002.120202] [Citation(s) in RCA: 1565] [Impact Index Per Article: 71.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Miguel A Quiñones
- American Society of Echocardiography, 1500 Sunday Drive, Suite 102, Raleigh, NC 27607, USA
| | | | | | | | | |
Collapse
|
21
|
Azpitarte J, Sánchez-Ramos J, Urda T, Vivancos R, Oyonarte JM, Malpartida F. [Prosthetic valve thrombosis: which is the most appropriate initial therapy?]. Rev Esp Cardiol 2001; 54:1367-76. [PMID: 11754805 DOI: 10.1016/s0300-8932(01)76519-0] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
INTRODUCTION AND OBJECTIVES This study aims to investigate what is the best initial therapy for patients with obstructive prosthetic valve thrombosis. METHODS Data from 47 patients diagnosed with prosthetic valve thrombosis in two tertiary hospitals during an 8-years period were analyzed. RESULTS The involved prostheses were in mitral position in 34 cases (2 biological valves), in aortic position in 12, and in double mitral and aortic position in one. The thrombosis was not obstructive in 12 patients. In the remaining 35 patients, the prosthetic obstruction was treated by heparin (n = 2), thrombolysis (n = 19), or direct surgery (n = 14). There was no mortality in the thrombolytic group, although 6 patients needed surgery before discharge because of an abnormal prosthetic residual gradient (n = 5) or a persisting abnormal disc valve motion (n = 1). Five out of 14 patients of direct surgery died, 2 before the planned operation could be performed. Thus, mortality rate, in an intention to treat analysis, was very favourable to thrombolytic therapy (p = 0.008); and this, despite the higher index of clinical severity (on a scale from 0 to 4) was superior in this group of thrombolyzed patients: 3.3 0.6 vs. 2.1 0.9 in those who underwent surgery; p < 0.0001. CONCLUSIONS In terms of mortality rate, thrombolysis is a better alternative than direct surgery to fight against obstructive prosthetic valve thrombosis. Even if the result is suboptimal, it allows the performance of surgery in better clinical conditions and, thus, with minor risk.
Collapse
Affiliation(s)
- J Azpitarte
- Servicios de Cardiología de los Hospitales Virgen de las Nieves de Granada y aCarlos de Haya Málaga.
| | | | | | | | | | | |
Collapse
|
22
|
O'Rourke DJ, Palac RT, Malenka DJ, Marrin CA, Arbuckle BE, Plehn JF. Outcome of mild periprosthetic regurgitation detected by intraoperative transesophageal echocardiography. J Am Coll Cardiol 2001; 38:163-6. [PMID: 11451267 DOI: 10.1016/s0735-1097(01)01361-4] [Citation(s) in RCA: 121] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
OBJECTIVES The goal of this study was to determine the outcome of trivial or mild periprosthetic regurgitation (PPR) identified by intraoperative transesophageal echocardiography (TEE). BACKGROUND The clinical significance, natural history and correlates of trivial or mild PPR detected early after surgery are unknown. METHODS Between 1992 and 1997, 608 consecutive patients underwent isolated aortic valve replacement or mitral valve replacement at Dartmouth-Hitchcock Medical Center. Of these, 113 patients (18.3%) were found to have trivial or mild PPR at surgery by TEE. Follow-up transthoracic echocardiograms (early TTEs) were obtained within six weeks of surgery in 99.0% of patients and late TTEs (mean 2.1 years) in 54.3%. Clinical, intraoperative and outcome variables associated with PPR were identified using t test, chi-square and logistic regression analyses. RESULTS By univariate analysis, compared with patients without PPR, patients with PPR were older, of smaller body surface area (BSA), had degenerative valve disease more often and were more likely to receive a bioprosthetic valve. By multivariate analysis, smaller BSA and the use of a bioprosthesis were the strongest predictors of PPR (p < 0.01). At early TTE, PPR was not observed (n = 56) or remained unchanged (n = 44) in all patients. At late TTE, four patients were found to have progression of their PPR. All four patients had bioprosthetic valves. Two of these patients had endocarditis, and one had primary valvular degeneration. The fourth patient had progressive PPR. CONCLUSIONS Trivial or mild PPR is a frequent finding on intraoperative TEE. Smaller body size and the use of a bioprosthetic valve are significantly associated with PPR. The clinical significance and natural history of PPR is benign in most cases.
Collapse
Affiliation(s)
- D J O'Rourke
- Section of Cardiology, Veterans Affairs Hospital, White River Junction, Vermont, USA. Daniel.O'
| | | | | | | | | | | |
Collapse
|
23
|
Renzulli A, De Feo M, De Santo L, Corte AD, Dialetto G, Cotrufo M. Standard 19mm St Jude aortic valves in patients with body surface less than 1.7m 2. Int J Artif Organs 2001. [DOI: 10.1177/039139880102400411] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Although new models of bileaflet valves with improved orifice have been devised, aortic valve replacement with 19mm prostheses still raises concerns about long term effects of residual transprosthetic gradient. We reviewed our experience with 19 mm standard model St Jude prostheses in 68 patients operated on between January 1983 and December 1995. Clinical late assessment was performed to evaluate the incidence of valve related complications. Postoperative echocardiography was performed to evaluate hemodynamic performance of the prostheses. Mean body surface area was 1.66±0.14m2. Late postoperative peak gradient was 53.85±7.16 mmHg; mean gradient was 34.80±5.55 mm Hg; effective orifice area was 1.93±0.05 cm2. Thirteen-year actuarial survival has been 90.89 ± 0.6%; thirteen-year freedom from embolism 89.41 ± 0.7% and freedom from hemorrhage 98.25 ± 0.02%. No case of prosthetic endocarditis, thrombosis, or reoperation was observed during follow-up.
Collapse
Affiliation(s)
- A. Renzulli
- Department of Cardio-Thoracic and Respiratory Sciences, V. Monaldi Hospital, Second University of Naples, Naples - Italy
| | - M. De Feo
- Department of Cardio-Thoracic and Respiratory Sciences, V. Monaldi Hospital, Second University of Naples, Naples - Italy
| | - L.S. De Santo
- Department of Cardio-Thoracic and Respiratory Sciences, V. Monaldi Hospital, Second University of Naples, Naples - Italy
| | - A. Della Corte
- Department of Cardio-Thoracic and Respiratory Sciences, V. Monaldi Hospital, Second University of Naples, Naples - Italy
| | - G. Dialetto
- Department of Cardio-Thoracic and Respiratory Sciences, V. Monaldi Hospital, Second University of Naples, Naples - Italy
| | - M. Cotrufo
- Department of Cardio-Thoracic and Respiratory Sciences, V. Monaldi Hospital, Second University of Naples, Naples - Italy
| |
Collapse
|
24
|
Ismeno G, Renzulli A, De Feo M, Della Corte A, Covino FE, Cotrufo M. Standard versus hemodynamic plus 19-mm St Jude Medical aortic valves. J Thorac Cardiovasc Surg 2001; 121:723-8. [PMID: 11279414 DOI: 10.1067/mtc.2001.113023] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
OBJECTIVE We reviewed our experience with aortic valve replacement using 19-mm St Jude Medical prostheses (St Jude Medical, Inc, St Paul, Minn) in 119 patients, among which 68 (group A) had a Standard model and 51 (group B) had a Hemodynamic Plus model. METHODS Comparison between the 2 models included analysis of early and late mortality and all valve-related complications. Postoperative echocardiography was performed to evaluate the hemodynamic performance of both prosthetic models. Laboratory tests were performed to evaluate the amount of red blood cell damage caused by the transprosthetic turbulent flow. RESULTS Average body surface area was 1.66 +/- 0.14 m(2) in group A and 1.65 +/- 0.16 m(2) in group B (P =.72). There was no statistically significant difference between the 2 groups in terms of preoperative variables (sex, cardiac rhythm, body surface area, preoperative gradients, and New York Heart Association class). Five-year follow-up was 100% complete. Although group A patients had significantly higher postoperative peak and mean gradients (P =.0001) and a lower effective orifice area (P =.0001), no statistical differences were found in terms of late (5-year) survival (P =.6) and postoperative complications (P =.09). Moreover, postoperative left ventricular mass was found to be similar in the 2 groups (P =.18). Hematologic evaluation did not show any significant difference between the 2 groups as to incidence of hemolysis. CONCLUSIONS Aortic valve replacement with 19-mm aortic prostheses in patients with a body surface area of less than 1.7 m(2) allows good results. Although Hemodynamic Plus models have better hemodynamic results, no significant difference was found in terms of clinical results and clinical hemolysis.
Collapse
Affiliation(s)
- G Ismeno
- Department of Cardio-Thoracic and Respiratory Sciences, V. Monaldi Hospital, Second University of Naples, Italy
| | | | | | | | | | | |
Collapse
|
25
|
Novaro GM, Connolly HM, Miller FA. Doppler hemodynamics of 51 clinically and echocardiographically normal pulmonary valve prostheses. Mayo Clin Proc 2001; 76:155-60. [PMID: 11213303 DOI: 10.1016/s0025-6196(11)63122-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
OBJECTIVE To determine the normal Doppler hemodynamics of various pulmonary valve prostheses (PVPs). PATIENTS AND METHODS We retrospectively analyzed comprehensive Doppler echocardiographic examinations of 51 patients (mean age, 27.8 years; range, 1-59 years) with PVPs that were normal on clinical and 2-dimensional echocardiographic examinations to establish the normal hemodynamics of various types and sizes of PVPs. The earliest complete postoperative transthoracic echocardiogram was identified for each patient. Doppler examinations were analyzed for peak instantaneous velocity, right ventricular outflow tract velocity, and peak and mean systolic gradient. The frequency of prosthetic regurgitation was also noted. RESULTS The average +/- SD peak instantaneous velocity for all PVPs was 2.24+/-0.6 m/s, with an average peak systolic gradient of 20.4+/-10.4 mm Hg and an average mean systolic gradient of 11.0+/-5.1 mm Hg. The mean right ventricular outflow tract velocity was 1.0+/-0.2 m/s. Pulmonary homografts were found to have significantly lower peak velocities (average, 1.8+/-0.6 m/s) than all heterografts combined (average, 2.4+/-0.5 m/s; P=.002). Prosthetic regurgitation was more common in pulmonary homografts (88%) than in heterografts combined (29%; P<.001). CONCLUSION This study establishes the normal range for Doppler hemodynamics of various PVPs, specifically homografts and heterografts, in both pediatric and adult patients.
Collapse
Affiliation(s)
- G M Novaro
- Department of Internal Medicine, Mayo Clinic, Rochester, Minn. 55905, USA
| | | | | |
Collapse
|
26
|
Abstract
TEE overcomes many of the imaging constraints associated with transthoracic echocardiography for the assessment of valvular anatomy and function. Additional imaging artifacts and constraints associated with prosthetic valves are minimized or overcome with TEE. As such, TEE allows assessment of prosthetic valve anatomy and function and paraprosthetic anatomy, and serves as the diagnostic imaging modality of choice for patients with suspected prosthesis dysfunction or endocarditis.
Collapse
Affiliation(s)
- D S Bach
- Division of Cardiology, Department of Medicine, University of Michigan, Ann Arbor, Michigan, USA.
| |
Collapse
|
27
|
Connolly HM, Oh JK, Schaff HV, Roger VL, Osborn SL, Hodge DO, Tajik AJ. Severe aortic stenosis with low transvalvular gradient and severe left ventricular dysfunction:result of aortic valve replacement in 52 patients. Circulation 2000; 101:1940-6. [PMID: 10779460 DOI: 10.1161/01.cir.101.16.1940] [Citation(s) in RCA: 249] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND The outcome of aortic valve replacement in patients with severe aortic stenosis, low transvalvular gradient, and severe left ventricular dysfunction is not well known. METHODS AND RESULTS Between 1985 and 1995, 52 patients with left ventricular ejection fraction (EF) < or =35% and aortic stenosis with transvalvular mean gradient <30 mm Hg underwent aortic valve replacement. The mean (+/-SD) preoperative characteristics included EF, 26+/-8%; aortic valve mean gradient, 23+/-4 mm Hg; aortic valve area, 0.7+/-0.2 cm(2); and cardiac output, 3.7+/-1.2 L/min. Simultaneous coronary artery bypass graft surgery was performed in 32 patients (62%). Perioperative (30-day) mortality was 21% (11 of 52 patients). Ten additional patients died during follow-up. Advanced age (P=0.048) and small aortic prosthesis size (P=0.03) were significant predictors of hospital mortality by univariate analysis. By multivariate analysis, the only predictor of surgical mortality was smaller prosthesis size. The only predictor of postoperative survival was improvement in postoperative functional class (P=0.04). Postoperative functional improvement occurred in most patients. Postoperative EF was assessed in 93% of survivors; 74% demonstrated improvement. Positive change in EF was related to smaller preoperative aortic valve area and female sex. CONCLUSIONS Despite severe left ventricular dysfunction, low transvalvular mean gradient, and increased operative mortality, aortic valve replacement was associated with improved functional status. Postoperative survival was related to younger patient age and larger aortic prosthesis size, and medium-term survival was related to improved postoperative functional class.
Collapse
Affiliation(s)
- H M Connolly
- Division of Cardiovascular Diseases and Internal Medicine, Mayo Clinic and Mayo Foundation, Rochester, MN 55905, USA
| | | | | | | | | | | | | |
Collapse
|
28
|
Affiliation(s)
- M Zabalgoitia
- Echocardiography Laboratories, University of Texas Health Science Center, San Antonio, USA
| |
Collapse
|
29
|
Botnar R, Nagel E, Scheidegger MB, Pedersen EM, Hess O, Boesiger P. Assessment of prosthetic aortic valve performance by magnetic resonance velocity imaging. MAGMA (NEW YORK, N.Y.) 2000; 10:18-26. [PMID: 10697222 DOI: 10.1007/bf02613108] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
OBJECTIVES Magnetic resonance (MRI) velocity mapping was used to evaluate non-invasively the flow profiles of the ascending aorta in normal volunteers and in patients with an aortic (mechanical) valve prosthesis. BACKGROUND In patients with artificial aortic valves the flow profile in the ascending aorta is severely altered. These changes have been associated with an increased risk of thrombus formation and mechanical hemolysis. METHODS Velocity profiles were determined 30 mm distal to the aortic valve in six healthy volunteers and seven patients with aortic valve replacement (replacement within the last 2 years) using ECG triggered phase contrast MRI. Peak flow, mean flow and mean reverse flow were measured in intervals of 25 ms during the entire heart cycle. Systolic reverse flow, end-systolic closing and diastolic leakage volume were calculated for all subjects. RESULTS Peak flow velocity during mid-systole was significantly higher in patients with valvular prosthesis than in normals (mean + SD, 1.9 +/- 0.4 m/s vs. 1.2 +/- 0.03 m/s, P < 0.001) with a double peak and a zone of reversed flow close to the inner (left lateral) wall of the ascending aorta of the patients. Closing volume was significantly larger in patients than in controls (-3.3 +/- 1.2 ml/beat vs. -0.9 +/- 0.5 ml/beat; P < 0.001). There was reverse flow during systole in valvular patients amounting to 15.7 +/- 6.7% of total cardiac output compared to 2.3 +/- 1.2% in controls (P < 0.001). Diastolic mean flow was negative in patients after valve replacement but not in controls (-11.0 +/- 15.2 ml/beat vs. 6.8 +/- 3.2 ml/beat; P < 0.01). CONCLUSIONS The following three major quantitative observations have been made in the present study: (1) Mechanical valve prostheses have an increased peak flow velocity with a systolic reverse flow at the inner (left lateral) wall of the ascending aorta. (2) A double peak flow velocity pattern can be observed in patients with bileaflet (mechanical) prosthesis. (3) The blood volume required for leaflet closure and the diastolic leakage blood volume are significantly higher for the examined bileaflet valve than for native heart valves.
Collapse
Affiliation(s)
- R Botnar
- Institute of Biomedical Engineering, University of Zurich and Swiss Federal Institute of Technology.
| | | | | | | | | | | |
Collapse
|
30
|
Evangelista Masip (coordinador) A, Alonso Gómez ÁM, Durán RM, Yagüela MM, Oliver Ruiz JM, Padial LR, Tobaruela A. Guías de práctica clínica de la Sociedad Española de Cardiología en ecocardiografía. Rev Esp Cardiol 2000. [DOI: 10.1016/s0300-8932(00)75144-x] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
31
|
Rallidis LS, Moyssakis IE, Ikonomidis I, Nihoyannopoulos P. Natural history of early aortic paraprosthetic regurgitation: a five-year follow-up. Am Heart J 1999; 138:351-7. [PMID: 10426851 DOI: 10.1016/s0002-8703(99)70124-9] [Citation(s) in RCA: 170] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
OBJECTIVES To assess the incidence and natural course of paravalvular leaks detected early after aortic valve replacement. BACKGROUND Although the use of echocardiography has simplified the postoperative assessment of patients with aortic valve replacement, there are no data regarding the natural history of early detected paravalvular aortic leaks. METHODS Eighty-four consecutive patients with aortic valve replacement were prospectively followed clinically every 6 months and by echocardiography early (11 +/- 7 days), at midterm (27 +/- 3 months), and late (63 +/- 4 months) after aortic valve replacement. The competence of artificial valves was assessed by Doppler color flow mapping. RESULTS Paraprosthetic leaks were detected in 40 (47.6%) aortic prostheses during the early study; the majority (90%) were small. All leaks remained unchanged during the follow-up period. Left ventricular dimensions and function did not differ between patients with or without paravalvular leak during the follow-up. Left ventricular fractional shortening, however, increased during the intermediate study in both subgroups, indicating improved left ventricular function overall. Three patients had severe paravalvular regurgitation suddenly develop from late infective endocarditis, and 1 patient had a degenerative tissue valve failure 4 years after implantation. CONCLUSIONS Paraprosthetic aortic leaks detected early after surgery, in the absence of valve infection, are common, are usually small, and have a benign course. However, the development of new, usually severe, regurgitation should raise the suspicion of prosthetic valve endocarditis or bioprosthetic valve failure.
Collapse
Affiliation(s)
- L S Rallidis
- Cardiology Department, Hammersmith Hospital, Imperial College School of Medicine, Du Cane Road, London, United Kingdom
| | | | | | | |
Collapse
|
32
|
Eriksson MJ, Rosfors S, Rådegran K, Brodin LA. Effects of exercise on Doppler-derived pressure difference, valve resistance, and effective orifice area in different aortic valve prostheses of similar size. Am J Cardiol 1999; 83:619-22, A10. [PMID: 10073878 DOI: 10.1016/s0002-9149(98)00930-8] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The effects of increased transvalvular volume flow on Doppler-derived measurements were compared in similarly sized, normally functioning, mechanical prostheses, stented and stentless porcine bioprostheses, and homografts. Homograft and stentless valves showed the largest effective orifice area and the lowest pressure differences and valve resistance at rest and during exercise-induced increase in flow rates.
Collapse
Affiliation(s)
- M J Eriksson
- Department of Clinical Physiology, Karolinska Hospital and Karolinska Institute, Stockholm, Sweden.
| | | | | | | |
Collapse
|
33
|
Olmos L, Salazar G, Barbetseas J, Quiñones MA, Zoghbi WA. Usefulness of transthoracic echocardiography in detecting significant prosthetic mitral valve regurgitation. Am J Cardiol 1999; 83:199-205. [PMID: 10073821 DOI: 10.1016/s0002-9149(98)00824-8] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
To identify the transthoracic echo-Doppler (TTE) variables most predictive of significant mitral regurgitation (MR) of mechanical prosthetic valves, TTE and trans-esophageal echo (TEE) studies were independently reviewed in 57 patients (mean age [+/-SD] 59+/-12.5 years) undergoing both studies within 2+/-3 days. Several 2-dimensional and Doppler hemodynamic variables from the TTE studies were derived. Prosthetic MR was significant (moderate or severe) by TEE in 20 patients, whereas mild or no MR was seen in 37 patients. The best univariate predictors of significant MR by TTE were peak velocity of mitral inflow, mean gradient, tricuspid regurgitation velocity, isovolumic relaxation time, and ratio of time velocity integral of mitral inflow to time velocity integral in the left ventricular outflow (TVI(MV)/TVI(LVO)). Peak mitral velocity and TVI(MV)/TVI(LVO) were the best predictors of significant MR and performed similarly (area under the receiver-operating characteristic curve: 0.97 for both). A peak velocity of > or =1.9 m/s was 90% sensitive and 89% specific for significant prosthetic MR, whereas a TVI(MV)/TVI(LVO) > or =2.5 had a sensitivity and specificity of 89% and 91%, respectively. A decision tree was constructed to assess the conditional probabilities of having significant MR given all the possible outcomes of the 2 best predictors. None of the patients with peak velocity < 1.9 m/s and TVI(MV)/TVI(LVO) <2.5 by TTE had significant MR. Conversely, all patients with peak velocity > or =1.9 m/s and TVI(MV)/TVI(LVO) > or =2.5 had significant MR. The use of more complex algorithms did not further improve the results. Thus, measurements of hemodynamic Doppler variables on TTE examination can accurately identify a large number of patients without significant prosthetic MR, thereby reducing the need for further investigation with TEE.
Collapse
Affiliation(s)
- L Olmos
- Department of Medicine, Baylor College of Medicine, The Methodist Hospital, Houston, Texas 77030, USA
| | | | | | | | | |
Collapse
|
34
|
Van Nooten G, Caes F, François K, Van Belleghem Y, Taeymans Y. Stentless or stented aortic valve implants in elderly patients? Eur J Cardiothorac Surg 1999; 15:31-6. [PMID: 10077370 DOI: 10.1016/s1010-7940(98)00288-7] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/17/2022] Open
Abstract
OBJECTIVE To assess differences in indication and mid-term results between stentless and stented procedures in elderly patients, we followed aortic valve patients over a period of 5 years. METHODS In a consecutive series of 154 elderly aortic patients in regular sinus rhythm from 1992 to 1997, we inserted 103 stentless (Toronto SPVTM, St Jude Medical Inc., St Paul, Minneapolis, MN) and 51 stented (Carpentier-Edwards supra annular porcine, Baxter Inc., Irvine, CA) bioprostheses in the aortic position. RESULTS All 154 patients seemed preoperatively eligible for a stentless procedure. Mean age was 74.8 years (range 67-86 years) with a majority of female patients. The surgeon's (in)experience, major dilatation or calcifications of the ascending aorta and aberrant coronary anatomy were the most common reasons for drawback from the stentless procedure (51/154 patients). Aortic clamp time was significantly higher in the stentless vs. stented group (70 vs. 57 min, P < 0.0001). The large average 25.3 mm size of the stentless prostheses (vs. 23.7 mm stented) stands in full contrast with the low mean body surface area of 1.68 m2 (vs. 1.70 m2) of the patients. We encountered. respectively. 5 and 2 hospital-deaths (P = n.s.). The follow-up period ranged from 6 to 66 months and was 97% complete, yielding, respectively, 302 and 139 patient-years. Survival (Kaplan-Meier method) was statistically higher in favor of the stentless procedures (log rank: P = 0.03). All survivors progressed markedly to a mean postoperative NYHA class 1.3 respectively, 1.4 (vs. preop. 3.3 and 3.2). Echocardiographic transvalvular gradients compared favorable for the stentless group in the small under 25 mm valves (P = 0.02 for 23 mm sized valves between groups) with improved left ventricular function and a significant decrease of left ventricular end diastolic diameter (LVEDD 48.0 vs. 56.5 mm) at 1 year follow-up. Cusp calcifications on control echocardiography were detected earlier (beyond 3 years) in the stented group, without signs of early significant regurgitation or dysfunction in both groups, except for one patient necessitating re-operation. CONCLUSION Although the implantation technique is much more demanding for stentless procedures, reflected by a longer aortic clamp-time, and remains impossible in some cases, elderly, small sized patients take full benefit of their large, non-obstructive prostheses.
Collapse
Affiliation(s)
- G Van Nooten
- Cardiac Surgery Department, University Hospital Gent, Ghent, Belgium.
| | | | | | | | | |
Collapse
|
35
|
Solowiejczyk DE, Yamada I, Cape EG, Manduley RA, Gersony WM, Jones M, Valdes-Cruz LM. Simultaneous Doppler and catheter transvalvular pressure gradients across St Jude bileaflet mitral valve prosthesis: in vivo study in a chronic animal model with pediatric valve sizes. J Am Soc Echocardiogr 1998; 11:1145-54. [PMID: 9923995 DOI: 10.1016/s0894-7317(98)80011-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
A mixture of valve types has been used in previous in vivo studies to assess the accuracy of Doppler echocardiography compared with catheter-measured pressure gradients across prosthetic mitral valves. However, limited data exist regarding the most commonly used bileaflet mechanical valve. We studied 14 sheep with St Jude Medical mechanical mitral valves. Continuous wave Doppler data were obtained across each of the 3 valve orifices. Hemodynamic data were obtained simultaneously by direct measurements with catheters. Valve sizes commonly used in the pediatric population in the mitral position (23 mm, 25 mm, and 27 mm) were studied. Linear regression analyses of Doppler-predicted versus catheter-measured gradients provided correlation coefficients ranging from 0.75 to 0.91. Agreement analysis demonstrated a scatter of Doppler data about the regression line. Although a reasonably good correlation of Doppler-predicted peak and mean pressure gradients across bileaflet mechanical valves exists in the mitral position, caution is needed when this method is applied to patients. Doppler overestimation was greatest across the 23-mm valves. Analyses of the specific orifice interrogated demonstrated higher estimated pressure gradients across the central orifice compared with the side orifices.
Collapse
Affiliation(s)
- D E Solowiejczyk
- Division of Pediatric Cardiology, Columbia Presbyterian Medical Center, New York, NY 10032, USA.
| | | | | | | | | | | | | |
Collapse
|
36
|
Reisner SA, Harpaz D, Skulski R, Borenstein D, Milo S, Meltzer RS. Hemodynamic performance of four mechanical bileaflet prosthetic valves in the mitral position: an echocardiographic study. EUROPEAN JOURNAL OF ULTRASOUND : OFFICIAL JOURNAL OF THE EUROPEAN FEDERATION OF SOCIETIES FOR ULTRASOUND IN MEDICINE AND BIOLOGY 1998; 8:193-200. [PMID: 9971902 DOI: 10.1016/s0929-8266(98)00076-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
OBJECTIVES The CarboMedics, Duromedics, Sorin Bicarbon and the St. Jude Medical valves are bileaflet mechanical prostheses of modern but different design. Choosing a valve with the best hemodynamic profile is of clinical importance in patients with small ventricles and a small mitral annulus. METHODS The hemodynamic performance of these valves in the mitral position was compared in 76 asymptomatic, ambulatory patients with normally functioning prosthesis and left ventricle, using Doppler echocardiography. Of the 76 patients studied, 22 had the CarboMedics, 16 had the Duromedics, 17 had the Sorin Bicarbon and 21 had the St. Jude prosthesis. The patients ages ranged from 18 to 81 years. There were 44 women and 32 men. The time from implantation to echocardiographic study ranged from 1 to 55 months. RESULTS The echocardiographic study was performed earlier after surgery in the Sorin Bicarbon group. There was no significant difference in women/man ratio, incidence of atrial fibrillation, left ventricular or left atrial diameters between the four groups. The mean prosthesis size was significantly smaller for Sorin Bicarbon and Duromedics valves compared to the CarboMedics and the St. Jude valves (mean+/-SD, 27.2+/-1.3, 27.1+/-1.1 and 30.0+/-1.9 and 30.0+/-2.7 mm, respectively, P<0.001). Despite its smaller size the Sorin Bicarbon valve had significantly larger effective valve area by Doppler compared to the CarboMedics valve (290+/-40 vs 250+/-60 mm2, respectively, P=0.014). The ratio of effective valve area to prosthesis size was significantly larger for the Sorin Bicarbon valve when compared with any other type of prosthesis. CONCLUSIONS (1) The Sorin Bicarbon bileaflet valve offered the best hemodynamic results that may be explained by the valve's large leaflet opening angle and small thickness of the leaflets. (2) Since the Sorin Bicarbon is the newest bileaflet valve, durability of this valve remains uncertain.
Collapse
Affiliation(s)
- S A Reisner
- Department of Cardiology, Ramban and Walfson Medical Center, Faculty of Medicine, Technion-Israel Institute of Technology, 31096, Haifa, Israel
| | | | | | | | | | | |
Collapse
|
37
|
Abstract
Mechanical prosthetic valve thrombosis is a life-threatening complication necessitating immediate intervention. The presenting signs and symptoms of this illness are somewhat variable, but physical examination and transesophageal echocardiography enable rapid diagnosis. To avoid catastrophic complications, valve replacement or debridement, or thrombolysis in the correct setting, must be performed without delay. It is not entirely clear which therapy is superior. For any given patient, the risks of thrombolytic therapy, including bleeding, systemic embolism, and failure to restore valvular function, must be weighed against the risks of surgical intervention. Once the decision is made to operate, the choice of valve replacement versus debridement is one best made intraoperatively, upon visual inspection of the valve apparatus. Despite aggressive therapy, morbidity and mortality from prosthetic valve thrombosis and its treatment are not trivial. Fortunately, with current prosthetic devices and aggressive prophylactic anticoagulation, the incidence of prosthetic valve thrombosis remains low. Antiplatelet therapy may offer additional benefit to patients being prophylaxed with warfarin. This report details the case of a woman with aortic and mitral prosthetic valves who presented with heart failure and evidence of severe aortic prosthetic dysfunction after a period of suboptimal anticoagulation. She successfully underwent debridement of the mitral prosthesis and replacement of the aortic valve. The relevant literature is reviewed.
Collapse
|
38
|
Barbetseas J, Nagueh SF, Pitsavos C, Toutouzas PK, Quiñones MA, Zoghbi WA. Differentiating thrombus from pannus formation in obstructed mechanical prosthetic valves: an evaluation of clinical, transthoracic and transesophageal echocardiographic parameters. J Am Coll Cardiol 1998; 32:1410-7. [PMID: 9809956 DOI: 10.1016/s0735-1097(98)00385-4] [Citation(s) in RCA: 162] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
OBJECTIVES We sought to determine the clinical and echocardiographic parameters that differentiate thrombus from pannus formation as the etiology of obstructed mechanical prosthetic valves. BACKGROUND Distinction of thrombus from pannus on obstructed prosthetic valves is essential because thrombolytic therapy has emerged as an alternative to reoperation. METHODS We analyzed clinical, transthoracic and transesophageal echocardiography (TEE) data in 23 patients presenting with 24 obstructed prosthetic valves and compared the findings to pathology at surgery. RESULTS Fourteen valves had thrombus and 10 had pannus formation. Patients with thrombus had a shorter duration from time of valve insertion to malfunction, shorter duration of symptoms, but similar New York Heart Association functional class at the time of operation. Patients with thrombus had a lower rate of adequate anticoagulation (21% vs. 89%; p=0.0028). Pannus formation was more common in the aortic position (70% vs. 21%; p=0.035). Abnormal prosthetic valve motion was detected by TEE in all cases with thrombus formation but in 60% with pannus (p=0.0198). Thrombi were larger than pannuses (total length 2.8+/-2.47 cm vs. 1.17+/-0.43 cm; p=0.038). This was mostly due to extension of thrombi into the left atrium in prosthetic mitral valves. Thrombi appeared as a soft mass on the valve in 92% of cases, whereas 29% of pannuses had a soft echo density (p= 0.007). Ultrasound video intensity ratio, derived as the videointensity of the mass to that of the prosthetic valve, was lower in the thrombus group (0.46+/-0.14 vs. 0.71+/-0.17, p=0.006). A videointensity ratio of <0.70 had a positive predictive value of 87% and a negative predictive value of 89% for thrombus. Duration from onset of symptoms to reoperation of <1 month separated thrombus from pannus formation. The best objective clinical parameter for prediction of thrombus was inadequate anticoagulation, whereas the best TEE parameters were qualitative and quantitative ultrasound intensity of the mass. The presence of either inadequate anticoagulation or a soft mass by TEE improved the predictive power of either parameter alone and was similar to that of ultrasound videointensity ratio. CONCLUSIONS Duration of symptoms, anticoagulation status and qualitative and quantitative ultrasound intensity of the mass obstructing a mechanical prosthetic valve can help differentiate pannus formation from thrombus and may therefore be of value in refining the selection of patients for thrombolytic therapy of prosthetic valve obstruction.
Collapse
Affiliation(s)
- J Barbetseas
- Department of Internal Medicine, Baylor College of Medicine, The Methodist Hospital, Houston, Texas 77030, USA
| | | | | | | | | | | |
Collapse
|
39
|
Mykén PS, Berggren HE, Larsson S, Roberts B, Wallentin I, Caidahl K. Long-term Doppler echocardiographic results of aortic or mitral valve replacement with Biocor porcine bioprosthesis. J Thorac Cardiovasc Surg 1998; 116:599-608. [PMID: 9766588 DOI: 10.1016/s0022-5223(98)70166-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
Abstract
OBJECTIVES Our objectives were to evaluate the long-term bioprosthetic and cardiac functional outcome after insertion (over a 10-year period) of a new-generation porcine zero pressure-fixed Biocor bioprosthesis, as well as to determine the echocardiographic accuracy for selection of patients requiring reoperation. The long-term systematic Doppler echocardiographic assessment after valve replacement with this bioprosthesis is lacking. METHODS Between January 1983 and January 1993, we inserted 756 Biocor prostheses in the aortic (619) or mitral (137) positions. All 51 patients who had a reoperation during the follow-up time were evaluated echocardiographically before reoperation. Additionally, 263 of 446 patients (59%) with aortic bioprostheses and 42 of 74 patients (57%) with mitral bioprostheses who were alive in January 1993 had long-term echocardiographic follow-up. RESULTS Group A: Normally functioning bioprostheses were found in the aortic position in 242 of 263 patients and in the mitral position in 33 of 42 patients. Group B: Thirty patients had abnormal bioprosthetic function. Eleven patients had regurgitation, 3 had a combined lesion, and signs of calcification appeared in 16 patients with aortic valves, all with a peak gradient of above 60 mm Hg. Group C: Patients who had a reoperation (41 aortic and 10 mitral) within the follow-up period were followed up echocardiographically from the detection of a possible valve dysfunction until reoperation, and the findings accorded well with those at operation in 49 of 51 patients. CONCLUSIONS These findings suggest that, during a long-term follow-up, most bioprostheses function normally, facilitating improved heart function. Abnormalities in a bioprosthesis usually develop gradually, enabling their detection by Doppler echocardiographic evaluations performed regularly or in case of any symptomatic deterioration.
Collapse
Affiliation(s)
- P S Mykén
- Department of Thoracic and Cardiovascular Surgery, Sahlgrenska University Hospital, Göteborg, Sweden
| | | | | | | | | | | |
Collapse
|
40
|
Çam N, Gerçekoğlu H, Çelik S, Gürsürer M, Tayyareci G, Karabulut H, Narin A, Tezel T, Yiğiter B. Dobutamine Stress Test to Evaluate Different Sizes of Prosthetic Aortic Valves. Asian Cardiovasc Thorac Ann 1998. [DOI: 10.1177/021849239800600305] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Dobutamine stress testing and Doppler echocardiography were used to assess hemodynamics in 27 patients aged 16 to 54 years with various sizes and types of aortic valve prosthesis. All patients underwent a symptom-limited treadmill exercise test within two days of the dobutamine test. There was no significant difference in ejection fractions and transvalvular gradients at rest and during dobutamine stress between St. Jude Medical, Medtronic-Hall, and Carbomedics valves. Exercise duration did not differ significantly among the different types of valve. When patients were classified by their underlying lesion, those with aortic stenosis and those with aortic insufficiency had similar ejection fractions and transvalvular gradients at rest and during dobutamine stress. The mean and peak transvalvular gradients at rest and during dobutamine stress were significantly different in patients with different valve sizes but the extent of the increase in gradients during stress was not significant. Linear regression analysis revealed that both peak and mean gradients during dobutamine stress could be predicted by the resting gradients. There was a negative correlation between valve size and gradients at rest and during stress, while there was a significant correlation between exercise duration and valve size. Dobutamine stress echocardiography was useful for studying hemodynamics in patients with aortic valve prostheses and the findings show that valvular size was the main determinant of exercise capacity.
Collapse
Affiliation(s)
| | - Hakan Gerçekoğlu
- Department of Cardiovascular Surgery Siyami Ersek Thoracic and Cardiovascular Surgery Center İstanbul, Turkey
| | | | | | | | - Hasan Karabulut
- Department of Cardiovascular Surgery Siyami Ersek Thoracic and Cardiovascular Surgery Center İstanbul, Turkey
| | | | | | - Besim Yiğiter
- Department of Cardiovascular Surgery Siyami Ersek Thoracic and Cardiovascular Surgery Center İstanbul, Turkey
| |
Collapse
|
41
|
Abstract
Significant advances in imaging modalities have occurred to evaluate prosthetic valve function and associated complications. These developments involve predominantly the introduction of Doppler technology for the non-invasive determination of gradients and valve areas and TEE for an improved assessment of valve structure, function, and associated complications. The current role of cinefluoroscopy is mostly to complement TEE in the evaluation of motion of mechanical prosthetic valves in the aortic position. Cardiac catheterization is now rarely needed to assess valve function. Diagnosis of prosthetic valve obstruction can be performed in the majority of cases with transthoracic Doppler echocardiography. Differentiation of valve obstruction from normal valve function in small valves with high flow conditions, however, may be difficult. Because of this and the variability in normal valves among different prostheses, knowledge of the type and size of the implanted valve is essential. Patients and ultrasound laboratories are encouraged to seek and provide this information on a routine basis. Although transthoracic echocardiography is the main diagnostic modality for the serial evaluation of prosthetic valve function, it is important to recognize its limitations in assessing prosthetic mitral regurgitation and evaluating structural abnormalities of prosthetic valves. These are the situations in which TEE has the most impact. A summary of general indications of TEE in prosthetic valves is provided in Table 6. Finally, a baseline transthoracic Doppler study is essential in the overall follow-up and serial evaluation of valve function. For future comparisons, the best indices of valve functions are those obtained for patients as their own control, from a baseline Doppler echocardiographic study performed early after the operation.
Collapse
Affiliation(s)
- J Barbetseas
- Department of Medicine, Baylor College of Medicine, Houston, Texas, USA
| | | |
Collapse
|
42
|
Chakraborty B, Quek S, Pin DZ, Siong CT, Kheng TL. Evaluation of normal hemodynamic profile of CarboMedics prosthetic valves by Doppler echocardiography. Angiology 1997; 48:1055-61. [PMID: 9404832 DOI: 10.1177/000331979704801206] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The authors investigated 163 CarboMedics bileaflet prosthetic valves--81 mitral prostheses (MP), and 82 aortic prostheses (AP)--to determine acceptable pressure gradients across normally functioning prostheses and effective mitral valve orifice (MVO) area by Doppler echocardiography. In MP, the mean gradient was 3.6+/-1.7 mm Hg, peak transmitral gradient was 8.7+/-3.7 mm Hg, and mean effective valve area was 2.3+/-0.7 cm2. There was a significant overlap in mean and peak transaortic gradients even with valves of the same size. In AP, the mean gradient was 14.7+/-5.1 mm Hg and peak pressure gradient was 26.1+/-8.2 mm Hg. They observed a weak inverse correlation between valve size and gradients in AP. Mean and peak pressure gradients tended to be higher with smaller valve sizes, but differences were statistically significant (P < 0.5) only when they compared the smallest vs the largest valves. Trivial to mild regurgitation was detected in 28.4% of MP and 54.8% of AP. From the data they conclude that CarboMedics valves offer relatively little resistance to forward flow, both in the mitral and aortic positions, and their hemodynamic profile is comparable to that of the St. Jude bileaflet valves described in published literature.
Collapse
Affiliation(s)
- B Chakraborty
- Department of Cardiology, Singapore General Hospital, Outram Park
| | | | | | | | | |
Collapse
|
43
|
Saad RM, Barbetseas J, Olmos L, Rubio N, Zoghbi WA. Application of the continuity equation and valve resistance to the evaluation of St. Jude Medical prosthetic aortic valve dysfunction. Am J Cardiol 1997; 80:1239-42. [PMID: 9359564 DOI: 10.1016/s0002-9149(97)00652-8] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Doppler echocardiography was applied to the assessment of patients with surgically documented St. Jude medical aortic valve dysfunction. Derivation of effective orifice area and Doppler velocity index with the continuity equation and calculation of valve resistance accurately differentiated stenotic from regurgitant and normal valves.
Collapse
Affiliation(s)
- R M Saad
- Department of Medicine, Baylor College of Medicine, and The Methodist Hospital Echocardiography Laboratory Houston, Texas 77030, USA
| | | | | | | | | |
Collapse
|
44
|
Zabalgoitia M, Kopec K, Abochamh DA, Oneschuk L, Herrera CJ, O'Rourke RA. Usefulness of dobutamine echocardiography in the hemodynamic assessment of mechanical prostheses in the aortic valve position. Am J Cardiol 1997; 80:523-6. [PMID: 9285673 DOI: 10.1016/s0002-9149(97)00410-4] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Dobutamine stress echocardiography is a simple, safe, and readily available method to evaluate prosthetic valve hemodynamics under various flow conditions. A normal response of aortic valve prostheses to dobutamine infusion is a 100% increment in transprosthetic pressure gradients with an unchanged valve area.
Collapse
Affiliation(s)
- M Zabalgoitia
- Department of Medicine/Cardiology, The University of Texas Health Science Center at San Antonio, 78284-7872, USA
| | | | | | | | | | | |
Collapse
|
45
|
Cheitlin MD, Alpert JS, Armstrong WF, Aurigemma GP, Beller GA, Bierman FZ, Davidson TW, Davis JL, Douglas PS, Gillam LD. ACC/AHA Guidelines for the Clinical Application of Echocardiography. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Clinical Application of Echocardiography). Developed in collaboration with the American Society of Echocardiography. Circulation 1997; 95:1686-744. [PMID: 9118558 DOI: 10.1161/01.cir.95.6.1686] [Citation(s) in RCA: 377] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
|
46
|
Shimada I, Okabayashi H, Nishina T, Minatoya K, Soga Y, Matsubayashi K, Kamikawa Y, Tanabe A, Kanai Y, Miyamoto AT. Doppler Hemodynamics of CarboMedics Prosthetic Valves in Aortic Position at Rest and Exercise. Asian Cardiovasc Thorac Ann 1996. [DOI: 10.1177/021849239600400305] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
To evaluate the size adequacy of CarboMedics prosthetic heart valves, Doppler pressure gradients after aortic valve replacement were determined at rest and immediately after exercise in 83 patients, at a mean time of 18.8 days after aortic valve replacement with CarboMedics prosthetic heart valves (31 standard and 52 R-series). There were 54 males and 29 females, average age 55 years; 12 had pure aortic stenosis, 47 had aortic regurgitation, and 24 had combined lesions. Exercise significantly increased (p < 0.01) the peak velocity (from 2.50 to 2.88 m/sec), the peak pressure gradient (from 25.9 to 34.6 mm Hg), and the mean pressure gradient (from 13.9 to 18.4 mm Hg). Significant differences were observed even in patients with seemingly large valve sizes. Significant correlation (p < 0.0001) was observed between pressure gradients at rest and immediately after exercise, as well as between pressure gradients and theoretical performance index. A theoretical performance index larger than 1.0 cm2/m2 was needed to obtain a postexercise Doppler peak pressure gradient of less than 60 mm Hg early after aortic valve replacement using either the Carbomedics standard or R-series prosthetic heart valves.
Collapse
|
47
|
Aoyagi S, Fukunaga S, Suzuki S, Nishi Y, Oryoji A, Kosuga K. Obstruction of mechanical valve prostheses: clinical diagnosis and surgical or nonsurgical treatment. Surg Today 1996; 26:400-6. [PMID: 8782297 DOI: 10.1007/bf00311926] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Twenty patients underwent nonsurgical and/or surgical treatment for obstruction of mechanical prosthetic valves. The obstructed prosthetic valve was in the aortic position in 11 patients, in the mitral position in 5, and in the tricuspid position in 4. Twelve patients had a bileaflet valve (3 aortic, 5 mitral, 4 tricuspid), and 8 had a tilting disk valve (all aortic). The diagnosis of prosthetic valve obstruction was made by cineradiography and echocardiography. Thrombolytic therapy was instituted in a series of our 10 most recent patients (11 cases), except for one patient with acute renal failure, regardless of the position of the obstructed prosthetic valve. Successful thrombolysis was achieved in 6 cases (54.5%). Six patients required surgical treatment subsequent to either failed or incomplete thrombolysis, and one patient died of congestive heart failure 1 month after surgery. Nonfatal neurologic events occurred in 2 cases (18.2%). A total of 16 patients underwent surgical treatment. Two (12.6%) of the 16 patients died of causes unrelated to the operative procedures before discharge from the hospital. These results suggest that thrombolytic therapy appears to be an attractive nonsurgical alternative for valve thrombosis when the patient's clinical condition is not critical, and thus surgical treatment should only be performed in an emergency on seriously ill patients.
Collapse
Affiliation(s)
- S Aoyagi
- Second Department of Surgery, Kurume University School of Medicine, Japan
| | | | | | | | | | | |
Collapse
|
48
|
Van Nooten G, Caes F, François K, Missault L, Van Belleghem Y. Clinical experience with the first 100 ATS heart valve implants. CARDIOVASCULAR SURGERY (LONDON, ENGLAND) 1996; 4:288-92. [PMID: 8782921 DOI: 10.1016/0967-2109(95)00123-9] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Between May 1992 and March 1994, 100 consecutive patients had 119 new ATS mechanical bileaflet valves inserted (61 aortic, 50 mitral, eight tricuspid). The mean age of the patients was 63.7 (range 13-82) years. The follow-up period ranged from 5 to 27 months and was complete in all cases. Before surgery, 53 aortic valve patients were in New York Heart Association functional class III or higher. This improved to a mean of 1.3 postoperatively, all patients being in classes I or II. One patient died in hospital, and another 3 months after implantation (actuarial survival rate 98%). One patient had an embolic event 9 days after an aortic valve reoperation which caused a parietal infarction. One tricuspid valve blocked in the open position 6 weeks after implantation as a result of inadequate anticoagulation and was successfully unblocked after 2 days of intensive thrombolytic therapy. Patients were treated by mild anticoagulation without developing bleeding complications. Echocardiographic, transoesophageal and transthoracic valvular gradients compared favourably with the gradients reported in other mechanical valves (including small aortic valves). The haemodynamics were excellent without evidence of significant regurgitation. This was confirmed by an in vitro hydrodynamic evaluation of the valve using a pulse duplicator system. The valve closure caused little noise and was as a result well tolerated.
Collapse
Affiliation(s)
- G Van Nooten
- Cardiac Surgery Department, University Hospital Ghent, Belgium
| | | | | | | | | |
Collapse
|
49
|
Hurrell DG, Schaff HV, Tajik AJ. Thrombolytic therapy for obstruction of mechanical prosthetic valves. Mayo Clin Proc 1996; 71:605-13. [PMID: 8642893 DOI: 10.4065/71.6.605] [Citation(s) in RCA: 46] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
This report describes two patients who were treated for obstruction of St. Jude tricuspid valve prostheses. In the patient with the hypereosinophilic syndrome, right heart failure developed 15 days after valve replacement. The other patient had symptoms of right heart failure for 8 weeks; these occurred 15 months after valve implantation. In both patients, thrombolytic therapy was successful and without major sequelae. Herein we review the literature on the use of thrombolysis for obstructed mechanical prosthetic valves and completely summarize the English literature; the efficacy of thrombolysis for obstructed prosthetic valves and the associated morbidity and mortality are emphasized. Recommendations for thrombolysis in clinical practice are provided.
Collapse
Affiliation(s)
- D G Hurrell
- Division of Cardiovascular Diseases, Mayo Clinic Rochester, Minnesota 55905, USA
| | | | | |
Collapse
|
50
|
Affiliation(s)
- B Wranne
- Department of Clinical Physiology, Linköping Heart Centre, University Hospital, Sweden
| | | | | | | | | |
Collapse
|