1
|
Conangla-Planes M, Serres X, Persiva O, Augustín S. Imaging diagnosis of portal hypertension. RADIOLOGIA 2018. [DOI: 10.1016/j.rxeng.2018.04.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
2
|
Conangla-Planes M, Serres X, Persiva O, Augustín S. Diagnóstico por imagen de la hipertensión portal. RADIOLOGIA 2018; 60:290-300. [DOI: 10.1016/j.rx.2017.12.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2017] [Revised: 12/29/2017] [Accepted: 12/30/2017] [Indexed: 12/23/2022]
|
3
|
Schaffner D, von Elverfeldt D, Deibert P, Lazaro A, Merfort I, Lutz L, Neubauer J, Baumstark MW, Kreisel W, Reichardt W. Phase-contrast MR flow imaging: A tool to determine hepatic hemodynamics in rats with a healthy, fibrotic, or cirrhotic liver. J Magn Reson Imaging 2017; 46:1526-1534. [PMID: 28240794 DOI: 10.1002/jmri.25677] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2016] [Accepted: 02/01/2017] [Indexed: 12/14/2022] Open
Abstract
PURPOSE To test a magnetic resonance (MR) scanning protocol as a noninvasive tool to determine hepatic hemodynamics and to assess the degree of liver fibrosis in an animal model of liver fibrosis and cirrhosis. MATERIALS AND METHODS Fifty-four male Wistar rats were studied. Thirty-nine received thioacetamide (TAA) in their drinking water for either 12 or 16 weeks. MR measurements were performed using flow-sensitive 2D phase-contrast MRI and a 9.4T preclinical scanner. The following hemodynamic parameters were investigated: portal cross-sectional area, mean portal flow velocity, and portal and aortic flow volume rate. Therefore, rats (n = 46) were divided into three groups: CON (control, n = 13), FIB (fibrosis, n = 25), and CIR (cirrhosis, n = 8). Furthermore, the degree of liver fibrosis was assessed by a self-established MR score and verified by a standardized histological score (n = 48). RESULTS Portal and aortic flow parameters could be reliably detected. A significant decrease in portal flow velocity was found in FIB (FIB vs. CON: -21%, P = 0.006 and CIR vs. CON: -17%, P = 0.105) and in portal flow volume rate in FIB and CIR (FIB vs. CON: -20%, P = 0.009 and CIR vs. CON: -25%, P = 0.024). If the histological score is taken as standard, the self-established MR score enabled discrimination between healthy and diseased livers (sensitivity to identify diseased livers: 89% and specificity to identify healthy livers: 100%). CONCLUSION This MR scanning protocol presents a noninvasive tool to determine hepatic hemodynamics in healthy and diseased rats. LEVEL OF EVIDENCE 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2017;46:1526-1534.
Collapse
Affiliation(s)
- Denise Schaffner
- Institute for Exercise- und Occupational Medicine, Medical Center, University of Freiburg, Germany
- Faculty of Medicine, University of Freiburg, Germany
- Department of Pharmaceutical Biology and Biotechnology, University of Freiburg, Germany
| | - Dominik von Elverfeldt
- Faculty of Medicine, University of Freiburg, Germany
- Department of Radiology, Medical Physics, Medical Center, University of Freiburg, Germany
| | - Peter Deibert
- Institute for Exercise- und Occupational Medicine, Medical Center, University of Freiburg, Germany
- Faculty of Medicine, University of Freiburg, Germany
| | - Adhara Lazaro
- Institute for Exercise- und Occupational Medicine, Medical Center, University of Freiburg, Germany
- Faculty of Medicine, University of Freiburg, Germany
| | - Irmgard Merfort
- Department of Pharmaceutical Biology and Biotechnology, University of Freiburg, Germany
| | - Lisa Lutz
- Faculty of Medicine, University of Freiburg, Germany
- Institute of Clinical Pathology, Medical Center, University of Freiburg, Germany
| | - Jakob Neubauer
- Faculty of Medicine, University of Freiburg, Germany
- Department of Radiology, Medical Center, University of Freiburg, Germany
| | - Manfred W Baumstark
- Institute for Exercise- und Occupational Medicine, Medical Center, University of Freiburg, Germany
- Faculty of Medicine, University of Freiburg, Germany
| | - Wolfgang Kreisel
- Faculty of Medicine, University of Freiburg, Germany
- Department of Medicine II, Gastroenterology, Hepatology, Endocrinology and Infectious Diseases, Medical Center, University of Freiburg, Germany
| | - Wilfried Reichardt
- Faculty of Medicine, University of Freiburg, Germany
- Department of Radiology, Medical Physics, Medical Center, University of Freiburg, Germany
- German Cancer Consortium (DKTK), Heidelberg, Germany
- German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|
4
|
Abdelaziz O, Attia H. Doppler ultrasonography in living donor liver transplantation recipients: Intra- and post-operative vascular complications. World J Gastroenterol 2016; 22:6145-72. [PMID: 27468207 PMCID: PMC4945976 DOI: 10.3748/wjg.v22.i27.6145] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/28/2016] [Revised: 05/18/2016] [Accepted: 06/13/2016] [Indexed: 02/06/2023] Open
Abstract
Living-donor liver transplantation has provided a solution to the severe lack of cadaver grafts for the replacement of liver afflicted with end-stage cirrhosis, fulminant disease, or inborn errors of metabolism. Vascular complications remain the most serious complications and a common cause for graft failure after hepatic transplantation. Doppler ultrasound remains the primary radiological imaging modality for the diagnosis of such complications. This article presents a brief review of intra- and post-operative living donor liver transplantation anatomy and a synopsis of the role of ultrasonography and color Doppler in evaluating the graft vascular haemodynamics both during surgery and post-operatively in accurately defining the early vascular complications. Intra-operative ultrasonography of the liver graft provides the surgeon with useful real-time diagnostic and staging information that may result in an alteration in the planned surgical approach and corrections of surgical complications during the procedure of vascular anastomoses. The relevant intra-operative anatomy and the spectrum of normal and abnormal findings are described. Ultrasonography and color Doppler also provides the clinicians and surgeons early post-operative potential developmental complications that may occur during hospital stay. Early detection and thus early problem solving can make the difference between graft survival and failure.
Collapse
|
5
|
Rotemberg V, Byram B, Palmeri M, Wang M, Nightingale K. Ultrasonic characterization of the nonlinear properties of canine livers by measuring shear wave speed and axial strain with increasing portal venous pressure. J Biomech 2013; 46:1875-81. [PMID: 23726184 DOI: 10.1016/j.jbiomech.2013.04.027] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2012] [Revised: 04/20/2013] [Accepted: 04/23/2013] [Indexed: 12/13/2022]
Abstract
Elevated hepatic venous pressure is the primary source of complications in advancing liver disease. Ultrasound imaging is ideal for potential noninvasive hepatic pressure measurements as it is widely used for liver imaging. Specifically, ultrasound based stiffness measures may be useful for clinically monitoring pressure, but the mechanism by which liver stiffness increases with hepatic pressure has not been well characterized. This study is designed to elucidate the nonlinear properties of the liver during pressurization by measuring both hepatic shear wave speed (SWS) and strain with increasing pressure. Tissue deformation during hepatic pressurization was tracked in 8 canine livers using successively acquired 3-D B-mode volumes and compared with concurrently measured SWS. When portal venous pressure was increased from clinically normal (0-5mmHg) to pressures representing highly diseased states at 20mmHg, the liver was observed to expand with axial strain measures up to 10%. At the same time, SWS estimates were observed to increase from 1.5-2m/s at 0-5mmHg (baseline) to 3.25-3.5m/s at 20mmHg.
Collapse
Affiliation(s)
- Veronica Rotemberg
- Department of Biomedical Engineering, Duke University, Room 136 Hudson Hall, Box 90281, Durham, NC 27708, USA.
| | | | | | | | | |
Collapse
|
6
|
Ribeiro RT, Marinho RT, Sanches JM. Classification and staging of chronic liver disease from multimodal data. IEEE Trans Biomed Eng 2012; 60:1336-44. [PMID: 23268381 DOI: 10.1109/tbme.2012.2235438] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
Chronic liver disease (CLD) is most of the time an asymptomatic, progressive, and ultimately potentially fatal disease. In this study, an automatic hierarchical procedure to stage CLD using ultrasound images, laboratory tests, and clinical records are described. The first stage of the proposed method, called clinical based classifier (CBC), discriminates healthy from pathologic conditions. When nonhealthy conditions are detected, the method refines the results in three exclusive pathologies in a hierarchical basis: 1) chronic hepatitis; 2) compensated cirrhosis; and 3) decompensated cirrhosis. The features used as well as the classifiers (Bayes, Parzen, support vector machine, and k -nearest neighbor) are optimally selected for each stage. A large multimodal feature database was specifically built for this study containing 30 chronic hepatitis cases, 34 compensated cirrhosis cases, and 36 decompensated cirrhosis cases, all validated after histopathologic analysis by liver biopsy. The CBC classification scheme outperformed the nonhierachical one against all scheme, achieving an overall accuracy of 98.67% for the normal detector, 87.45% for the chronic hepatitis detector, and 95.71% for the cirrhosis detector.
Collapse
Affiliation(s)
- Ricardo T Ribeiro
- Institute for Systems and Robotics, the Escola Superior de Tecnologia da Saúde de Lisboa, Lisbon, Portugal.
| | | | | |
Collapse
|
7
|
Doppler parameters of hepatic and renal hemodynamics in patients with liver cirrhosis. Int J Nephrol 2012; 2012:961654. [PMID: 22811907 PMCID: PMC3397178 DOI: 10.1155/2012/961654] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2012] [Revised: 03/25/2012] [Accepted: 04/24/2012] [Indexed: 01/04/2023] Open
Abstract
Introduction. There are limited studies on simultaneous evaluation of liver and renal blood flow using Doppler methods. We evaluated and compared the changes of liver and renal Doppler US parameters in patients with liver cirrhosis according to the degree of liver disease. Material and Methods. We assessed a large spectrum of liver and renal Doppler US parameters in 67 patients with liver cirrhosis. Results. Significant differences between Child's classes or score, as well as MELD score, were observed in all investigated intrarenal blood flow Doppler US parameters, except renal artery peak systolic velocity, but only in some of the hepatic ones. The deviations of renal Doppler US parameters were also related with the complications of liver cirrhosis, as well as serum urea and creatinine levels. There was relationship between Doppler US parameters of hepatic artery and the corresponding renal artery Doppler US parameters. The changes of Doppler US parameters were age independent. Conclusion. Our results show, renal Doppler US parameters correlate with the severity and complications of liver cirrhosis. Because of dynamic deviations of renal Doppler US parameters with advance of liver cirrhosis, we recommend Doppler US of renal artery as a part of follow up of these patients.
Collapse
|