O'Meara JM, Börjesson J, Chettle DR, Mattsson S. Normalisation with coherent scatter signal: improvements in the calibration procedure of the 57Co-based in vivo XRF bone-Pb measurement.
Appl Radiat Isot 2001;
54:319-25. [PMID:
11200895 DOI:
10.1016/s0969-8043(99)00279-1]
[Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The feasibility of a normalised calibration variable to account for interpatient variability for in vivo 57Co XRF (X-ray fluorescence) finger bone-lead measurements was assessed. Normalising the lead X-ray intensities to the coherent scatter signal was investigated by experiment and Monte Carlo simulation. The X-ray to coherent ratios for a fixed lead concentration were within 5-10% of the mean, within uncertainty, over a physiologically relevant range of finger bone sizes and overlying tissue thicknesses. This is an acceptable level of variation to introduce, as it is less than the uncertainty of a typical in vivo measurement. Normalisation has several advantages compared with the current method of correcting for interpatient variation, as it eliminates the need for transporting extensive equipment to on-site measurements, reduces the subject dose by a factor of two, and increases the objectivity of the bone-Pb assessment.
Collapse