1
|
Pogue BW, Wilson BC. Optical and x-ray technology synergies enabling diagnostic and therapeutic applications in medicine. JOURNAL OF BIOMEDICAL OPTICS 2018; 23:1-17. [PMID: 30350489 PMCID: PMC6197862 DOI: 10.1117/1.jbo.23.12.121610] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/25/2018] [Accepted: 09/24/2018] [Indexed: 05/10/2023]
Abstract
X-ray and optical technologies are the two central pillars for human imaging and therapy. The strengths of x-rays are deep tissue penetration, effective cytotoxicity, and the ability to image with robust projection and computed-tomography methods. The major limitations of x-ray use are the lack of molecular specificity and the carcinogenic risk. In comparison, optical interactions with tissue are strongly scatter dominated, leading to limited tissue penetration, making imaging and therapy largely restricted to superficial or endoscopically directed tissues. However, optical photon energies are comparable with molecular energy levels, thereby providing the strength of intrinsic molecular specificity. Additionally, optical technologies are highly advanced and diversified, being ubiquitously used throughout medicine as the single largest technology sector. Both have dominant spatial localization value, achieved with optical surface scanning or x-ray internal visualization, where one often is used with the other. Therapeutic delivery can also be enhanced by their synergy, where radio-optical and optical-radio interactions can inform about dose or amplify the clinical therapeutic value. An emerging trend is the integration of nanoparticles to serve as molecular intermediates or energy transducers for imaging and therapy, requiring careful design for the interaction either by scintillation or Cherenkov light, and the nanoscale design is impacted by the choices of optical interaction mechanism. The enhancement of optical molecular sensing or sensitization of tissue using x-rays as the energy source is an important emerging field combining x-ray tissue penetration in radiation oncology with the molecular specificity and packaging of optical probes or molecular localization. The ways in which x-rays can enable optical procedures, or optics can enable x-ray procedures, provide a range of new opportunities in both diagnostic and therapeutic medicine. Taken together, these two technologies form the basis for the vast majority of diagnostics and therapeutics in use in clinical medicine.
Collapse
Affiliation(s)
- Brian W. Pogue
- Dartmouth College, Thayer School of Engineering, Geisel School of Medicine, Hanover, New Hampshire, United States
| | - Brian C. Wilson
- University of Toronto, Princess Margaret Cancer Centre/University Health Network, Toronto, Ontario, Canada
| |
Collapse
|
2
|
Monserrate A, Zussman B, Ozpinar A, Niranjan A, Flickinger JC, Gerszten PC. Stereotactic radiosurgery for intradural spine tumors using cone-beam CT image guidance. Neurosurg Focus 2017; 42:E11. [DOI: 10.3171/2016.9.focus16356] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE
Cone-beam CT (CBCT) image guidance technology has been widely adopted for spine radiosurgery delivery. There is relatively little experience with spine radiosurgery for intradural tumors using CBCT image guidance. This study prospectively evaluated a series of intradural spine tumors treated with radiosurgery. Patient setup accuracy for spine radiosurgery delivery using CBCT image guidance for intradural spine tumors was determined.
METHODS
Eighty-two patients with intradural tumors were treated and prospectively evaluated. The positioning deviations of the spine radiosurgery treatments in patients were recorded. Radiosurgery was delivered using a linear accelerator with a beam modulator and CBCT image guidance combined with a robotic couch that allows positioning correction in 3 translational and 3 rotational directions. To measure patient movement, 3 quality assurance CBCTs were performed and recorded in 30 patients: before, halfway, and after the radiosurgery treatment. The positioning data and fused images of planning CT and CBCT from the treatments were analyzed to determine intrafraction patient movements. From each of 3 CBCTs, 3 translational and 3 rotational coordinates were obtained.
RESULTS
The radiosurgery procedure was successfully completed for all patients. Lesion locations included cervical (22), thoracic (17), lumbar (38), and sacral (5). Tumor histologies included schwannoma (27), neurofibromas (18), meningioma (16), hemangioblastoma (8), and ependymoma (5). The mean prescription dose was 17 Gy (range 12–27 Gy) delivered in 1–3 fractions. At the halfway point of the radiation, the translational variations and standard deviations were 0.4 ± 0.5, 0.5 ± 0.8, and 0.4 ± 0.5 mm in the lateral (x), longitudinal (y), and anteroposterior (z) directions, respectively. Similarly, the variations immediately after treatment were 0.5 ± 0.4, 0.5 ± 0.6, and 0.6 ± 0.5 mm along x, y, and z directions, respectively. The mean rotational angles were 0.3° ± 0.4°, 0.3° ± 0.4°, and 0.3° ± 0.4° along yaw, roll, and pitch, respectively, at the halfway point and 0.5° ± 0.5°, 0.4° ± 0.5°, and 0.2° ± 0.3° immediately after treatment.
CONCLUSIONS
Radiosurgery offers an alternative treatment option for intradural spine tumors in patients who may not be optimal candidates for open surgery. CBCT image guidance for patient setup for spine radiosurgery is accurate and successful in patients with intradural tumors.
Collapse
Affiliation(s)
| | | | | | | | - John C. Flickinger
- 2Radiation Oncology, University of Pittsburgh Medical Center; and
- 3Pittsburgh Cancer Institute, Pittsburgh, Pennsylvania
| | - Peter C. Gerszten
- Departments of 1Neurological Surgery and
- 2Radiation Oncology, University of Pittsburgh Medical Center; and
| |
Collapse
|
3
|
Patient specific quality assurance of RapidArc pre treatment plans using semiflex 0.125 cc ionization chamber. Radiat Phys Chem Oxf Engl 1993 2017. [DOI: 10.1016/j.radphyschem.2016.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
4
|
Yu VY, Fahimian BP, Xing L, Hristov DH. Quality control procedures for dynamic treatment delivery techniques involving couch motion. Med Phys 2014; 41:081712. [DOI: 10.1118/1.4886757] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
5
|
Gerszten PC, Quader M, Novotny J, Flickinger JC. Radiosurgery for Benign Tumors of the Spine: Clinical Experience and Current Trends. Technol Cancer Res Treat 2012; 11:133-9. [DOI: 10.7785/tcrt.2012.500242] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
In distinction to the development of the clinical indications for intracranial radiosurgery, spine radiosurgery's initial primary focus was and still remains the treatment of malignant disease. The role of stereotactic radiosurgery for the treatment of intracranial benign tumors has been well established. However, there is much less experience and much more controversy regarding the use of radiosurgery for the treatment of benign tumors of the spine. This study presents the clinical experience and current trends of radiosurgery in the treatment paradigm of benign tumors of the spine as part of a dedicated spine radiosurgery program. Forty consecutive benign spine tumors were treated using cone beam computed tomography (CBCT) image guidance technology for target localization. Lesion location included 13 cervical, 9 thoracic, 11 lumbar, and 7 sacral tumors. Thirty-four cases (85%) were intradural. The most common tumor histologies were schwannoma (15 cases), neurofibroma (7 cases), and meningioma (8 cases). Eighteen cases (45%) had previously undergone open surgical resection, and 4 lesions (10%) had previously been treated with conventional fractionated external beam irradiation techniques. This cohort was compared to a prior institutional experience of 73 consecutive benign spine tumors treated with radiosurgery. No subacute or long term spinal cord or cauda equina toxicity occurred during the follow-up period (median 26 months). Radiosurgery was used as the primary treatment modality in 22 cases (55%) and for recurrence after prior open surgical resection in 18 cases (45%). The mean prescribed dose to the gross tumor volume (GTV) was 14 Gy (range 11 to 17) delivered in a single fraction in 35 cases. In 5 cases in which the tumor was found to be intimately associated with the spinal cord with distortion of the spinal cord itself, the prescribed dose to the GTV was 18 to 21 Gy delivered in 3 fractions. The GTV ranged from 0.37 to 94.5 cm3 (mean 13.2 cm3, median 5.1 cm3). No evidence of tumor growth was seen on serial imaging in any case. Compared to the prior cohort, there was a trend towards increased patient age, GTV, and use of radiosurgery in the post-surgical setting, as well as a simultaneous decrease in the prescription dose. Radiosurgery is a safe and clinically effective treatment alternative for benign spinal neoplasms. While surgical extirpation is currently felt to be the best initial treatment option for most benign spinal tumors, spine radiosurgery has been demonstrated to have long-term clinical and radiographic benefit for the treatment of such lesions. In a similar manner in which spine radiosurgery has become a primary treatment option for a variety of intracranial benign tumors, radiosurgery may become the most favorable treatment alternative for similar histologies when found in the spine. The application of radiosurgery for non-neoplastic spine disease deserves future investigation.
Collapse
Affiliation(s)
- Peter C. Gerszten
- Departments of Neurological Surgery and Radiation Oncology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
| | - Mubina Quader
- Department of Radiation Oncology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
| | - Josef Novotny
- Department of Radiation Oncology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
| | - John C. Flickinger
- Departments of Neurological Surgery and Radiation Oncology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
| |
Collapse
|
6
|
Gerszten PC, Monaco EA, Quader M, Novotny J, Kim JO, Flickinger JC, Huq MS. Setup accuracy of spine radiosurgery using cone beam computed tomography image guidance in patients with spinal implants. J Neurosurg Spine 2010; 12:413-20. [PMID: 20367378 DOI: 10.3171/2009.10.spine09249] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECT Cone beam computed tomography (CBCT) image guidance technology has been adopted for use in spine radiosurgery. There is concern regarding the ability to safely and accurately perform spine radiosurgery without the use of implanted fiducials for image guidance in postsurgical cases in which titanium instrumentation and/or methylmethacrylate (MMA) has been implanted. In this study the authors prospectively evaluated the accuracy of the patient setup for spine radiosurgery by using CBCT image guidance in the context of orthopedic hardware at the site of disease. METHODS The positioning deviations of 31 single-fraction spine radiosurgery treatments in patients with spinal implants were prospectively evaluated using the Elekta Synergy S 6-MV linear accelerator with a beam modulator and CBCT image guidance combined with a robotic couch that allows positioning correction in 3 translational and 3 rotational directions. To measure patient movement, 3 quality-assurance CBCT studies were performed and recorded: before, halfway through, and after radiosurgical treatment. The positioning data and fused images of planning CTs and CBCTs from the treatments were analyzed to determine intrafractional patient movements. From each of 3 CBCTs, 3 translational and 3 rotational coordinates were obtained. RESULTS The prescribed dose to the gross tumor volume for the cohort was 12-18 Gy (mean 14 Gy) utilizing 9-14 coplanar intensity-modulated radiation therapy (IMRT) beams (mean 10 beams). At the halfway point of the radiosurgery, the translational variations and standard deviations were 0.6 +/- 0.6, 0.4 +/- 0.4, and 0.5 +/- 0.5 mm in the lateral (X), longitudinal (Y), and anteroposterior (Z) directions, respectively. The magnitude of the 3D vector (X,Y,Z) was 1.1 +/- 0.7 mm. Similarly, the variations immediately after treatment were 0.5 +/- 0.3, 0.4 +/- 0.4, and 0.5 +/- 0.6 mm along the X, Y, and Z directions, respectively. The 3D vector was 1.0 +/- 0.6 mm. The mean rotational angles were 0.3 +/- 0.4, 0.5 +/- 0.6, and 0.3 +/- 0.4 degrees along yaw, roll, and pitch, respectively, at the halfway point and 0.3 +/- 0.4, 0.6 +/- 0.6, and 0.4 +/- 0.5 degrees immediately after treatment. CONCLUSIONS Cone beam CT image guidance used for patient setup for spine radiosurgery was highly accurate despite the presence of spinal instrumentation and/or MMA at the level of the target volume. The presence of such spinal implants does not preclude safe treatment via spine radiosurgery in these patients.
Collapse
Affiliation(s)
- Peter C Gerszten
- Department of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA.
| | | | | | | | | | | | | |
Collapse
|
7
|
Amin MN, Norrlinger B, Heaton R, Islam M. Image guided IMRT dosimetry using anatomy specific MOSFET configurations. J Appl Clin Med Phys 2008; 9:69-81. [PMID: 18716593 PMCID: PMC5722303 DOI: 10.1120/jacmp.v9i3.2798] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2007] [Revised: 03/20/2008] [Accepted: 03/24/2008] [Indexed: 11/23/2022] Open
Abstract
We have investigated the feasibility of using a set of multiple MOSFETs in conjunction with the mobileMOSFET wireless dosimetry system, to perform a comprehensive and efficient quality assurance (QA) of IMRT plans. Anatomy specific MOSFET configurations incorporating 5 MOSFETs have been developed for a specially designed IMRT dosimetry phantom. Kilovoltage cone beam computed tomography (kV CBCT) imaging was used to increase the positional precision and accuracy of the detectors and phantom, and so minimize dosimetric uncertainties in high dose gradient regions. The effectiveness of the MOSFET based dose measurements was evaluated by comparing the corresponding doses measured by an ion chamber. For 20 head and neck IMRT plans the agreement between the MOSFET and ionization chamber dose measurements was found to be within −0.26±0.88% and 0.06±1.94% (1σ) for measurement points in the high dose and low dose respectively. A precision of 1 mm in detector positioning was achieved by using the X‐Ray Volume Imaging (XVI) kV CBCT system available with the Elekta Synergy Linear Accelerator. Using the anatomy specific MOSFET configurations, simultaneous measurements were made at five strategically located points covering high dose and low dose regions. The agreement between measurements and calculated doses by the treatment planning system for head and neck and prostate IMRT plans was found to be within 0.47±2.45%. The results indicate that a cylindrical phantom incorporating multiple MOSFET detectors arranged in an anatomy specific configuration, in conjunction with image guidance, can be utilized to perform a comprehensive and efficient quality assurance of IMRT plans. PACS number: 87.55.Qr
Collapse
Affiliation(s)
- Md Nurul Amin
- Department of Radiation Physics, Princess Margaret Hospital, University Health Network, Toronto, Ontario, Canada
| | - Bern Norrlinger
- Department of Radiation Physics, Princess Margaret Hospital, University Health Network, Toronto, Ontario, Canada
| | - Robert Heaton
- Department of Radiation Physics, Princess Margaret Hospital, University Health Network, Toronto, Ontario, Canada.,Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| | - Mohammad Islam
- Department of Radiation Physics, Princess Margaret Hospital, University Health Network, Toronto, Ontario, Canada.,Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
8
|
Escudé L, Linero D, Mollà M, Miralbell R. Quality assurance for radiotherapy in prostate cancer: Point dose measurements in intensity modulated fields with large dose gradients. Int J Radiat Oncol Biol Phys 2006. [DOI: 10.1016/j.ijrobp.2006.01.055] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
9
|
Vieira SC, Bolt RA, Dirkx MLP, Visser AG, Heijmen BJM. Fast, daily linac verification for segmented IMRT using electronic portal imaging. Radiother Oncol 2006; 80:86-92. [PMID: 16854483 DOI: 10.1016/j.radonc.2006.06.010] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2005] [Revised: 05/15/2006] [Accepted: 06/27/2006] [Indexed: 11/24/2022]
Abstract
PURPOSE Intensity modulated radiotherapy (IMRT) requires dedicated quality assurance (QA). Recently, we have published a method for fast (1-2 min) and accurate linac quality control for dynamic multileaf collimation, using a portal imaging device. This method is in routine use for daily leaf motion verification. The purpose of the present study was to develop an equivalent procedure for QA of IMRT with segmented (static) multileaf collimation (SMLC). MATERIALS AND METHODS The QA procedure is based on measurements performed during 3- to 8-month periods at Elekta, Siemens and Varian accelerators. On each measurement day, images were acquired for a field consisting of five 3 x 22 cm(2) segments. These 10 monitor unit (MU) segments were delivered in SMLC mode, moving the leaves from left to right. Deviations of realized leaf gap widths from the prescribed width were analysed to study the leaf positioning accuracy. To assess hysteresis in leaf positioning, the sequential delivery of the SMLC segments was also inverted. A static 20 x 20 cm(2) field was delivered with exposures between 1 and 50 MU to study the beam output and beam profile at low exposures. Comparisons with an ionisation chamber were made to verify the EPID dose measurements at low MU. Dedicated software was developed to improve the signal-to-noise ratio and to correct for image distortion. RESULTS AND CONCLUSIONS The observed long-term leaf gap reproducibility (1 standard deviation) was 0.1 mm for the Varian, and 0.2 mm for the Siemens and the Elekta accelerators. In all cases the hysteresis was negligible. Down to the lowest MU, beam output measurements performed with the EPID agreed within 1+/-1% (1SD) with ionisation chamber measurements. These findings led to a fast (3-4 min) procedure for accurate, daily linac quality control for SMLC.
Collapse
Affiliation(s)
- Sandra C Vieira
- Department of Radiation Oncology, Erasmus MC/Daniel den Hoed Cancer Center, Rotterdam, The Netherlands.
| | | | | | | | | |
Collapse
|
10
|
Chauvet I, Petitfils A, Lehobey C, Kristner JY, Brunet Y, Lembrez R, Gaboriaud G, Mazal A, Zefkili S, Rosenwald JC. The sliding slit test for dynamic IMRT: a useful tool for adjustment of MLC related parameters. Phys Med Biol 2005; 50:563-80. [PMID: 15773620 DOI: 10.1088/0031-9155/50/4/001] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
For treatments with dynamic intensity modulated radiotherapy (IMRT), the adjustment of multileaf collimator (MLC) parameters affecting both the optimization algorithm and dose distributions is crucial. The main parameters characterizing the MLC are the transmission (T) and the dosimetric leaf separation (DLS). The aim of this study is twofold: a methodology based on the 'sliding slit' test is proposed to determine (T, DLS) combinations inducing the best conformity between calculations and measurements. Secondly, the effects of the MLC adjustment on measured dose and on optimization are presented for different configurations as the chair test and for the patient dosimetric quality control (DQC). Tests were performed with a Varian 23EX linac operated at 20 MV and equipped with a 120 leaf Millenium dynamic collimator. The treatment planning system was CadPlan/Helios (version 6.3.6). Results demonstrated that the sliding width (SW) strongly depends on the (T, DLS) combinations, and the measured dose is a linear function of the SW. Different (T, DLS) combinations induced a good agreement between calculations and measurements. The influence of the MLC calibration was found to be particularly important on the 'sliding slit' test (11.8% for a gap change of 0.8 mm) but not so much on the chair test and on the DQC. To detect small variations in leaf adjustment and to ensure consistency between calculation and actual dose delivered to patients, a daily check called IMRT MU check is proposed.
Collapse
Affiliation(s)
- I Chauvet
- Department of Medical Physics, Institut Curie, 26 rue d'Ulm, 75005 Paris, France.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Arnfield MR, Otto K, Aroumougame VR, Alkins RD. The use of film dosimetry of the penumbra region to improve the accuracy of intensity modulated radiotherapy. Med Phys 2005; 32:12-8. [PMID: 15719949 DOI: 10.1118/1.1829246] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Accurate measurements of the penumbra region are important for the proper modeling of the radiation beam for linear accelerator-based intensity modulated radiation therapy. The usual data collection technique with a standard ionization chamber artificially broadens the measured beam penumbrae due to volume effects. The larger the chamber, the greater is the spurious increase in penumbra width. This leads to inaccuracies in dose calculations of small fields, including small fields or beam segments used in IMRT. This source of error can be rectified by the use of film dosimetry for penumbra measurements because of its high spatial resolution. The accuracy of IMRT calculations with a pencil beam convolution model in a commercial treatment planning system was examined using commissioning data with and without the benefit of film dosimetry of the beam penumbrae. A set of dose-spread kernels of the pencil beam model was calculated based on commissioning data that included beam profiles gathered with a 0.6-cm-i.d. ionization chamber. A second set of dose-spread kernels was calculated using the same commissioning data with the exception of the penumbrae, which were measured with radiographic film. The average decrease in the measured width of the 80%-20% penumbrae of various square fields of size 3-40 cm, at 5 cm depth in water-equivalent plastic was 0.27 cm. Calculations using the pencil beam model after it was re-commissioned using film dosimetry of the penumbrae gave better agreement with measurements of IMRT fields, including superior reproduction of high dose gradient regions and dose extrema. These results show that accurately measuring the beam penumbrae improves the accuracy of the dose distributions predicted by the treatment planning system and thus is important when commissioning beam models used for IMRT.
Collapse
Affiliation(s)
- Mark R Arnfield
- Department of Radiation Oncology, McKay-Dee Hospital Center, Ogden, Utah 84403, USA.
| | | | | | | |
Collapse
|
12
|
Ayyangar KM, Fung AYC, Li S, Pillai S, Yoe-Sein MM, Zhen W, Enke CA. Dose volume histogram comparison between ADAC Pinnacle and Nomos Corvus systems for IMRT. ACTA ACUST UNITED AC 2005; 28:1-7. [PMID: 15920983 DOI: 10.1007/bf03178857] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
This paper compares dose volume histograms (DVHs) generated by the ADAC Pinnacle and the Nomos Corvus planning systems. Seven prostate cases and seven head and neck cases were selected for review. Plans computed on both systems possessed exactly the same anatomical contours and IMRT segments. The Pinnacle system used the collapsed cone convolution superposition, while Corvus employed a finite size pencil beam (FSPB) convolution. Prostate DVH results demonstrated similar DVH curves from both systems. For each structure, the ratio of Pinnacle dose value divided by Corvus value was calculated. The high dose structures (which might contain tumour) had ratios close to unity, while the low dose structures (the critical organs) had ratios farther away from unity. Almost all ratios were less than unity, indicating a systematic difference that Pinnacle calculated doses were lower than Corvus ones. Head and neck data provided similar findings. A possible cause for this discrepancy could be the beam modelling. The difference in DVH parameters that we discovered between the two systems was about the same order of magnitude as the measurement-computation difference. When low dose is critical, such difference may affect the clinical planning decision.
Collapse
Affiliation(s)
- K M Ayyangar
- Department of Radiation Oncology, University of Nebraska Medical Center, Omaha 68198-7521, USA
| | | | | | | | | | | | | |
Collapse
|
13
|
Winkler P, Zurl B, Guss H, Kindl P, Stuecklschweiger G. Performance analysis of a film dosimetric quality assurance procedure for IMRT with regard to the employment of quantitative evaluation methods. Phys Med Biol 2005; 50:643-54. [PMID: 15773625 DOI: 10.1088/0031-9155/50/4/006] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
A system for dosimetric verification of intensity-modulated radiotherapy (IMRT) treatment plans using absolute calibrated radiographic films is presented. At our institution this verification procedure is performed for all IMRT treatment plans prior to patient irradiation. Therefore clinical treatment plans are transferred to a phantom and recalculated. Composite treatment plans are irradiated to a single film. Film density to absolute dose conversion is performed automatically based on a single calibration film. A software application encompassing film calibration, 2D registration of measurement and calculated distributions, image fusion, and a number of visual and quantitative evaluation utilities was developed. The main topic of this paper is a performance analysis for this quality assurance procedure, with regard to the specification of tolerance levels for quantitative evaluations. Spatial and dosimetric precision and accuracy were determined for the entire procedure, comprising all possible sources of error. The overall dosimetric and spatial measurement uncertainties obtained thereby were 1.9% and 0.8 mm respectively. Based on these results, we specified 5% dose difference and 3 mm distance-to-agreement as our tolerance levels for patient-specific quality assurance for IMRT treatments.
Collapse
Affiliation(s)
- Peter Winkler
- Department of Radiation Oncology, University Medical School, Auenbruggerplatz 32, 8036 Graz, Austria.
| | | | | | | | | |
Collapse
|
14
|
McNiven A, Kron T, Van Dyk J. A multileaf collimator phantom for the quality assurance of radiation therapy planning systems and CT simulators. Int J Radiat Oncol Biol Phys 2004; 60:994-1001. [PMID: 15465218 DOI: 10.1016/j.ijrobp.2004.06.013] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2004] [Revised: 06/02/2004] [Accepted: 06/16/2004] [Indexed: 10/26/2022]
Abstract
PURPOSE The evolution of three-dimensional conformal radiation treatment has led to the use of multileaf collimators (MLCs) in intensity-modulated radiation therapy (IMRT) and other treatment techniques to increase the conformity of the dose distribution. A new quality assurance (QA) phantom has been designed to check the handling of MLC settings in treatment planning and delivery. METHODS AND MATERIALS The phantom consists of a Perspex block with stepped edges that can be rotated in all planes. The design allows for the assessment of several MLC and micro-MLC types from various manufacturers, and is therefore applicable to most radiation therapy institutions employing MLCs. The phantom is computed tomography (CT) scanned as is a patient, and QA assessments can be made of field edge display for a variety of shapes and orientations on both radiation treatment planning systems (RTPS) and computed tomography simulators. RESULTS The dimensions of the phantom were verified to be physically correct within an uncertainty range of 0-0.7 mm. Errors in leaf position larger than 1 mm were easily identified by multiple observers. CONCLUSIONS The MLC geometry phantom is a useful tool in the QA of radiation therapy with application to RTPS, CT simulators, and virtual simulation packages with MLC display capabilities.
Collapse
Affiliation(s)
- Andrea McNiven
- Department of Medical Biophysics, University of Western Ontario, London Regional Cancer Centre, London, Ontario, Canada N6A 4L6
| | | | | |
Collapse
|
15
|
Suh Y, Yi B, Ahn S, Kim J, Lee S, Shin S, Shin S, Choi E. Aperture maneuver with compelled breath (AMC) for moving tumors: A feasibility study with a moving phantom. Med Phys 2004; 31:760-6. [PMID: 15124993 DOI: 10.1118/1.1650565] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Respiration causes target motion, which is known to be one of the technical bottlenecks in radiotherapy, especially for stereotactic radio-surgery and intensity modulated radiotherapy (IMRT). To overcome this problem, aperture maneuver with compelled breath (AMC) has been developed. In order to simulate compelled respiratory motion, a moving phantom using a ventilator was designed. As the air flow was forced to the bellows, which simulates the lungs, by a ventilator, a film connected to the ventilator moved like the respiratory target motion. A software was developed to transfer multileaf collimator motion from breathless to actual periodic breathing conditions. Static fields as well as step-and-shoot IMRT fields were modified in accordance with moving shapes to follow the target position, using the software with the controlled breathing information. Film dosimetry for a small field and for IMRT fields with a moving phantom was performed. To evaluate clinical implementation, five healthy volunteers were tested to breathe through a ventilator, and all of them could adapt the compelled breath without any difficulties. Additive margins for a moving target with AMC were not larger than 3 mm for respiratory organ motions up to 18 mm, while those with the static beam were 9 mm. For IMRT fields, large discrepancies were present between a static target and a moving target with the static beam, while they coincided well with AMC. Clinical acceptable differences between the dose distributions from a static target with the static beam and from a moving target with AMC revealed that this technique could be applied clinically.
Collapse
Affiliation(s)
- Y Suh
- Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, 388-1 Pungnap-dong Songpa-gu, Seoul, 138-736, Korea
| | | | | | | | | | | | | | | |
Collapse
|
16
|
Létourneau D, Gulam M, Yan D, Oldham M, Wong JW. Evaluation of a 2D diode array for IMRT quality assurance. Radiother Oncol 2004; 70:199-206. [PMID: 15028408 DOI: 10.1016/j.radonc.2003.10.014] [Citation(s) in RCA: 175] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2003] [Revised: 10/07/2003] [Accepted: 10/29/2003] [Indexed: 11/16/2022]
Abstract
BACKGROUND AND PURPOSE The QA of intensity modulated radiotherapy (IMRT) dosimetry is a laborious task. The goal of this work is to evaluate the dosimetric characteristics of a new 2D diode array (MapCheck from Sun Nuclear Corporation, Melbourne, Florida) and assess the role it can play in routine IMRT QA. MATERIAL AND METHODS Fundamental properties of the MapCheck such as reproducibility, linearity and temperature dependence are studied for high-energy photon beams. The accuracy of the correction for difference of diode sensitivity is also assessed. The diode array is benchmarked against film and ion chambers for conventional and IMRT treatments. The MapCheck sensitivity to multileaf collimator position errors is determined. RESULTS The diode array response is linear with dose up to 295 cGy. All diodes are calibrated to within +/-1% of each other, and mostly within +/-0.5%. The MapCheck readings are reproducible to within a maximum SD of +/-0.15%. A temperature dependence of 0.57%/ degrees C was noted and should be taken into account for absolute dosimetric measurement. Clinical performance of the MapCheck for relative and absolute dosimetry is demonstrated with seven beam (6 MV) head and neck IMRT plans, and compares well with film and ion chamber measurements. Comparison to calculated dose maps demonstrates that the planning system model underestimates the dose gradients in the penumbra region. CONCLUSIONS The MapCheck offers the dosimetric characteristics required for performing both relative and absolute dose measurements. Its use in the clinic can simplify and reduce the IMRT QA workload.
Collapse
Affiliation(s)
- Daniel Létourneau
- Department of Radiation Oncology, William Beaumont Hospital, 3601 W. Thirteen Mile Road, Royal Oak, MI 48073, USA
| | | | | | | | | |
Collapse
|
17
|
Saw CB, Ayyangar KM, Zhen W, Yoe-Sein M, Pillai S, Enke CA. Clinical implementation of intensity-modulated radiation therapy. Med Dosim 2002; 27:161-9. [PMID: 12074468 DOI: 10.1016/s0958-3947(02)00099-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The clinical implementation of intensity-modulated radiation therapy (IMRT) is a complex process because of the introduction of new treatment planning algorithms and beam delivery systems compared to conventional 3-dimensional conformal radiation therapy (3D-CRT) and the lack of established national performance protocols. IMRT uses an inverse-planning algorithm to create nonuniform fields that are only deliverable through a newly designed beam-modulating delivery system. The intent of this paper is to describe our experience and to elucidate the new clinical procedures that must be executed to have a successful IMRT program. Patients who undergo IMRT at our institution are immobilized and simulated before proceeding to computed tomography scan for patient data acquisition. Treatment planning involves the use of different prescription dose formats and different planning techniques compared to 3D-CRT. The desired dose goals for the target and sensitive structures must be specified before initiating the planning process, which is computer intensive. After the plan is completed, the delivery instructions are transferred to the delivery system via either a floppy disk for MIMiC-based IMRT or through the network for MLC-based IMRT. Target localizations are carried out using orthogonal radiographs. Ultrasound imaging system (BAT) is used to localize the prostate. Dose validation is performed using films, ion chambers or dose-calculation-based techniques.
Collapse
Affiliation(s)
- Cheng B Saw
- Department of Radiation Oncology, University of Nebraska Medical Center, Omaha 68198-7521, USA.
| | | | | | | | | | | |
Collapse
|
18
|
Williams M. A review of intensity modulated radiation therapy: incorporating a report on the seventh education workshop of the ACPSEM--ACT/NSW branch. Australasian College of Physical Scientists and Engineers in Medicine. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2002; 25:91-101. [PMID: 12416585 DOI: 10.1007/bf03178769] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
Intensity modulated radiation therapy (IMRT) is an evolving treatment technique that has become a clinical treatment option in several radiotherapy centres around the world. In August 2001 the ACT/NSW branch of the ACPSEM held its seventh education workshop, the subject was IMRT. This review considers the current use of IMRT and reports on the proceedings of the workshop. The workshop provided some of the theory behind IMRT, discussion of the practical issues associated with IMRT, and also involved presentations from Australian centres that had clinically implemented IMRT. The main topics of discussion were patient selection, plan assessment, multi-disciplinary approach, quality assurance and delivery of IMRT. Key points that were emphasised were the need for a balanced multi-disciplinary approach to IMRT, in both the establishment and maintenance of an IMRT program; the importance of the accuracy of the final dose distribution as compared to the minor in-field fluctuations of individual beams; and that IMRT is an emerging treatment technique, undergoing continuing development and refinement.
Collapse
Affiliation(s)
- M Williams
- The University of New South Wales, Kensington.
| |
Collapse
|
19
|
Abstract
Intensity-modulated radiation therapy (IMRT) requires the use of inverse treatment planning and nonuniform fluence beams delivered by a series of complex radiation portals. The quality assurance procedures for conventional three-dimensional conformal radiation therapy (3D-CRT) have been developed and are in worldwide clinical use, but the more complex nature of IMRT limits the application of much of the quality assurance (QA) procedures developed for IMRT. Although consensus has not yet been reached regarding which procedures will eventually become recommended by official organizations, the field is rapidly coming to agreement on a basic set of procedures. This manuscript describes some of the novel techniques recently developed for IMRT QA, both for the validation of the calculated dose distribution and for assuring that the dose distribution reaches its intended targets.
Collapse
Affiliation(s)
- Daniel A Low
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, MO 63110, USA.
| |
Collapse
|