• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4616374)   Today's Articles (2430)   Subscriber (49395)
For: Higgins DM, Whitehurst P, Morgan AM. The effect of carbon fiber couch inserts on surface dose with beam size variation. Med Dosim 2002;26:251-4. [PMID: 11704460 DOI: 10.1016/s0958-3947(01)00071-1] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Number Cited by Other Article(s)
1
Verde Nolasco A, de Faria LO. Head and Neck Immobilization Masks: Increase in Dose Surface Evaluated by EBT3, TLD‐100 and PBC Method. PRECISION RADIATION ONCOLOGY 2020. [DOI: 10.1002/pro6.1097] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]  Open
2
Photon beam attenuation characteristics of three commercial radiation therapy treatment couch-tops. JOURNAL OF RADIOTHERAPY IN PRACTICE 2018. [DOI: 10.1017/s1460396918000158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
3
Sdrolia A, Tambe N, Marsden JE, Wilson ML, Colley WP, Beavis AW. Investigation of the bolusing effect of the Varian Exact TM IGRT couch on flattened and flattening filter-free (FFF) photon beams of a Varian TrueBeam linac. Biomed Phys Eng Express 2018. [DOI: 10.1088/2057-1976/aaeb11] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
4
Sedaghatian T, Momennezhad M, Rasta SH, Makhdoomi Y, Abdollahian S. An Update of Couch Effect on the Attenuation of Megavoltage Radiotherapy Beam and the Variation of Absorbed Dose in the Build-up Region. J Biomed Phys Eng 2017;7:279-288. [PMID: 29082219 PMCID: PMC5654134] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2016] [Accepted: 09/22/2016] [Indexed: 06/07/2023]
5
Sheykhoo A, Abdollahi S, Hadizadeh Yazdi MH, Ghorbani M, Mohammadi M. Effects of Siemens TT-D carbon fiber table top on beam attenuation, and build up region of 6 MV photon beam. Rep Pract Oncol Radiother 2017;22:19-28. [PMID: 27790074 PMCID: PMC5071548 DOI: 10.1016/j.rpor.2016.09.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2015] [Revised: 06/29/2016] [Accepted: 09/01/2016] [Indexed: 10/20/2022]  Open
6
Sigamani A, Nambiraj A, Yadav G, Giribabu A, Srinivasan K, Gurusamy V, Raman K, Karunakaran K, Thiyagarajan R. Surface dose measurements and comparison of unflattened and flattened photon beams. J Med Phys 2016;41:85-91. [PMID: 27217619 PMCID: PMC4871008 DOI: 10.4103/0971-6203.181648] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]  Open
7
Gardner SJ, Gulam M, Song K, Li H, Huang Y, Zhao B, Qin Y, Snyder K, Kim J, Gordon J, Chetty IJ, Wen N. Generation and verification of QFix kVue Calypso-compatible couch top model for a dedicated stereotactic linear accelerator with FFF beams. J Appl Clin Med Phys 2015. [PMID: 26219010 PMCID: PMC5690015 DOI: 10.1120/jacmp.v16i4.5441] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]  Open
8
A practical method of modeling a treatment couch using cone-beam computed tomography for intensity-modulated radiation therapy and RapidArc treatment delivery. Med Dosim 2015;40:304-13. [PMID: 25934344 DOI: 10.1016/j.meddos.2015.03.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2014] [Revised: 02/15/2015] [Accepted: 03/29/2015] [Indexed: 11/22/2022]
9
Park JI, Ye SJ, Kim HJ, Park JM. Dosimetric effects of immobilization devices on SABR for lung cancer using VMAT technique. J Appl Clin Med Phys 2015;16:5217. [PMID: 25679178 PMCID: PMC5689970 DOI: 10.1120/jacmp.v16i1.5217] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2014] [Revised: 10/19/2014] [Accepted: 10/06/2014] [Indexed: 12/31/2022]  Open
10
Olch AJ, Gerig L, Li H, Mihaylov I, Morgan A. Dosimetric effects caused by couch tops and immobilization devices: Report of AAPM Task Group 176. Med Phys 2014;41:061501. [DOI: 10.1118/1.4876299] [Citation(s) in RCA: 78] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
11
Foo J, Stensmyr R. Depth dose comparison of measured and calculated dose for the Eclipse virtual carbon couch top models with air gap variation. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2013;36:457-63. [PMID: 24132584 DOI: 10.1007/s13246-013-0224-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2013] [Accepted: 10/08/2013] [Indexed: 11/26/2022]
12
Chan MF, Chiu-Tsao ST, Li J, Schupak K, Parhar P, Burman C. Confirmation of Skin Doses Resulting from Bolus Effect of Intervening Alpha-cradle and Carbon Fiber Couch in Radiotherapy. Technol Cancer Res Treat 2012;11:571-81. [PMID: 22712603 DOI: 10.7785/tcrt.2012.500269] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]  Open
13
Kry SF, Smith SA, Weathers R, Stovall M. Skin dose during radiotherapy: a summary and general estimation technique. J Appl Clin Med Phys 2012;13:3734. [PMID: 22584171 PMCID: PMC5716567 DOI: 10.1120/jacmp.v13i3.3734] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2011] [Revised: 12/27/2011] [Accepted: 12/28/2011] [Indexed: 11/23/2022]  Open
14
Seppälä JKH, Kulmala JAJ. Increased beam attenuation and surface dose by different couch inserts of treatment tables used in megavoltage radiotherapy. J Appl Clin Med Phys 2011;12:3554. [PMID: 22089010 PMCID: PMC5718753 DOI: 10.1120/jacmp.v12i4.3554] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2011] [Revised: 03/14/2011] [Accepted: 04/25/2011] [Indexed: 11/23/2022]  Open
15
The effect of the carbon fibre insert for the Varian Exact™ couch on the attenuation and build-up of high energy photon beams. JOURNAL OF RADIOTHERAPY IN PRACTICE 2011. [DOI: 10.1017/s1460396910000373] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
16
Mihaylov IB, Bzdusek K, Kaus M. Carbon fiber couch effects on skin dose for volumetric modulated arcs. Med Phys 2011;38:2419-23. [DOI: 10.1118/1.3576106] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]  Open
17
Li H, Lee AK, Johnson JL, Zhu RX, Kudchadker RJ. Characterization of dose impact on IMRT and VMAT from couch attenuation for two Varian couches. J Appl Clin Med Phys 2011;12:3471. [PMID: 21844859 PMCID: PMC5718645 DOI: 10.1120/jacmp.v12i3.3471] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2010] [Revised: 03/02/2011] [Accepted: 03/02/2011] [Indexed: 11/23/2022]  Open
18
Chiu-Tsao ST, Chan MF. Evaluation of two-dimensional bolus effect of immobilization/support devices on skin doses: a radiochromic EBT film dosimetry study in phantom. Med Phys 2010;37:3611-20. [PMID: 20831069 DOI: 10.1118/1.3439586] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]  Open
19
Smith DW, Christophides D, Dean C, Naisbit M, Mason J, Morgan A. Dosimetric characterization of the iBEAM evo carbon fiber couch for radiotherapy. Med Phys 2010;37:3595-606. [DOI: 10.1118/1.3451114] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
20
Court L, Urribarri J, Makrigiorgos M. Carbon fiber couches and skin sparing. J Appl Clin Med Phys 2010;11:3241. [PMID: 20592705 PMCID: PMC5719947 DOI: 10.1120/jacmp.v11i2.3241] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2009] [Accepted: 01/16/2010] [Indexed: 11/25/2022]  Open
21
Marguet M, Garcia R, Bordage MC. Évaluation d’une nouvelle table, Exact® IGRT (Varian), sur l’atténuation du faisceau de traitement et la qualité des images. Cancer Radiother 2010;14:42-9. [DOI: 10.1016/j.canrad.2009.07.041] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2008] [Revised: 07/03/2009] [Accepted: 07/13/2009] [Indexed: 11/24/2022]
22
Gerig LH, Niedbala M, Nyiri BJ. Dose perturbations by two carbon fiber treatment couches and the ability of a commercial treatment planning system to predict these effects. Med Phys 2009;37:322-8. [DOI: 10.1118/1.3271364] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
23
Mihaylov IB, Penagaricano J, Moros EG. Quantification of the skin sparing effect achievable with high-energy photon beams when carbon fiber tables are used. Radiother Oncol 2009;93:147-52. [PMID: 19515440 DOI: 10.1016/j.radonc.2009.05.008] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2008] [Revised: 05/05/2009] [Accepted: 05/08/2009] [Indexed: 12/25/2022]
24
Lee KW, Wu JK, Jeng SC, Hsueh Liu YW, Cheng JCH. Skin Dose Impact from Vacuum Immobilization Device and Carbon Fiber Couch in Intensity Modulated Radiation Therapy for Prostate Cancer. Med Dosim 2009;34:228-32. [DOI: 10.1016/j.meddos.2008.10.001] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2008] [Revised: 09/25/2008] [Accepted: 10/23/2008] [Indexed: 11/24/2022]
25
Njeh CF, Raines TW, Saunders MW. Determination of the photon beam attenuation by the Brainlab imaging couch: angular and field size dependence. J Appl Clin Med Phys 2009;10:16-27. [PMID: 19692980 PMCID: PMC5720553 DOI: 10.1120/jacmp.v10i3.2979] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2008] [Revised: 03/23/2009] [Accepted: 03/10/2009] [Indexed: 11/23/2022]  Open
26
Effect of a carbon fiber tabletop on the surface dose and attenuation for high-energy photon beams. ACTA ACUST UNITED AC 2008;26:539-44. [DOI: 10.1007/s11604-008-0271-6] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2008] [Accepted: 07/18/2008] [Indexed: 11/30/2022]
27
Spezi E, Angelini AL, Romani F, Guido A, Bunkheila F, Ntreta M, Ferri A. Evaluating the influence of the Siemens IGRT carbon fibre tabletop in head and neck IMRT. Radiother Oncol 2008;89:114-22. [DOI: 10.1016/j.radonc.2008.06.011] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2008] [Revised: 06/08/2008] [Accepted: 06/14/2008] [Indexed: 11/26/2022]
28
Spezi E, Ferri A. Dosimetric Characteristics of the Siemens IGRT Carbon Fiber Tabletop. Med Dosim 2007;32:295-8. [DOI: 10.1016/j.meddos.2006.11.006] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2006] [Accepted: 11/15/2006] [Indexed: 11/16/2022]
29
Butson MJ, Cheung T, Yu PKN. Megavoltage x-ray skin dose variation with an angle using grid carbon fibre couch tops. Phys Med Biol 2007;52:N485-92. [DOI: 10.1088/0031-9155/52/20/n03] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
30
Myint WK, Niedbala M, Wilkins D, Gerig LH. Investigating treatment dose error due to beam attenuation by a carbon fiber tabletop. J Appl Clin Med Phys 2006;7:21-7. [PMID: 17533341 PMCID: PMC5722426 DOI: 10.1120/jacmp.v7i3.2247] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2006] [Revised: 06/28/2006] [Accepted: 12/31/1969] [Indexed: 11/23/2022]  Open
31
McCormack S, Diffey J, Morgan A. The effect of gantry angle on megavoltage photon beam attenuation by a carbon fiber couch insert. Med Phys 2005;32:483-7. [PMID: 15789595 DOI: 10.1118/1.1852792] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
32
Hadley SW, Kelly R, Lam K. Effects of immobilization mask material on surface dose. J Appl Clin Med Phys 2005;6:1-7. [PMID: 15770192 PMCID: PMC5723508 DOI: 10.1120/jacmp.v6i1.1957] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]  Open
33
Vieira SC, Kaatee RSJP, Dirkx MLP, Heijmen BJM. Two-dimensional measurement of photon beam attenuation by the treatment couch and immobilization devices using an electronic portal imaging device. Med Phys 2003;30:2981-7. [PMID: 14655945 DOI: 10.1118/1.1620491] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA