• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4631606)   Today's Articles (3017)   Subscriber (49878)
For: Lund O, Pilegaard HK, Ilkjaer LB, Nielsen SL, Arildsen H, Albrechtsen OK. Performance profile of the Starr-Edwards aortic cloth covered valve, track valve, and silastic ball valve. Eur J Cardiothorac Surg 1999;16:403-13. [PMID: 10571086 DOI: 10.1016/s1010-7940(99)00249-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]  Open
Number Cited by Other Article(s)
1
De Martino A, Falcetta G, Milano AD, Bortolotti U. Modern concepts from old ideas in manufacture of cardiac valve prostheses. Indian J Thorac Cardiovasc Surg 2020;36:502-505. [PMID: 33061161 PMCID: PMC7525892 DOI: 10.1007/s12055-020-00941-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2019] [Revised: 02/10/2020] [Accepted: 02/12/2020] [Indexed: 11/29/2022]  Open
2
Amrane M, Soulat G, Carpentier A, Jouan J. Starr-Edwards aortic valve: 50+ years and still going strong: a case report. EUROPEAN HEART JOURNAL-CASE REPORTS 2017;1:ytx014. [PMID: 31020072 PMCID: PMC6176978 DOI: 10.1093/ehjcr/ytx014] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/06/2017] [Accepted: 10/26/2017] [Indexed: 11/13/2022]
3
Celik T, Bozlar U, Celik M, Demirkol S, Iyisoy A, Cingoz F. Giant left atrium in a patient with Starr-Edwards caged ball implanted three decades ago. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2010;12:266-7. [PMID: 21130710 DOI: 10.1016/j.carrev.2010.09.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2010] [Revised: 09/02/2010] [Accepted: 09/02/2010] [Indexed: 11/28/2022]
4
Si MS, Zapolanski A. A 37-Year-Old Smeloff-Cutter Aortic Valve. Ann Thorac Surg 2009;87:628-9. [PMID: 19161800 DOI: 10.1016/j.athoracsur.2008.07.018] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2007] [Revised: 06/08/2008] [Accepted: 07/09/2008] [Indexed: 10/21/2022]
5
Ikizler M, Birdane A, Sevin B. An old friend is still at work: 34-year-old well functioning Starr-Edwards aortic prosthesis without anticoagulation. Int J Cardiol 2006;116:e1-3. [PMID: 17052780 DOI: 10.1016/j.ijcard.2006.07.167] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/06/2006] [Accepted: 07/22/2006] [Indexed: 11/26/2022]
6
Shiono M, Sezai Y, Sezai A, Hata M, Iida M, Negishi N. Long-Term Results of the Cloth-Covered Starr-Edwards Ball Valve. Ann Thorac Surg 2005;80:204-9. [PMID: 15975368 DOI: 10.1016/j.athoracsur.2005.02.003] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/06/2004] [Revised: 01/22/2005] [Accepted: 02/01/2005] [Indexed: 11/20/2022]
7
Shiono M, Sezai A, Hata M, Iida M, Negishi N, Sezai Y. Valve dysfunction of the cloth-covered Starr-Edwards ball valve. Circ J 2005;69:844-9. [PMID: 15988111 DOI: 10.1253/circj.69.844] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
8
Tayama K, Akashi H, Tayama E, Fukunaga S, Kawara T, Kosuga KI, Aoyagi S. Replacement of an aortic Starr-Edwards ball valve prosthesis 28 years after implantation. Circ J 2004;68:507-8. [PMID: 15118298 DOI: 10.1253/circj.68.507] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
9
Naito Y, Nakajima M, Inoue H, Hibino N, Mizutani E, Tsuchiya K. Unexpected durability of Smeloff-Cutter aortic ball valve prosthesis. Ann Thorac Surg 2003;75:1633-5. [PMID: 12735595 DOI: 10.1016/s0003-4975(02)04784-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
10
Casselman FP, Bots ML, Van Lommel W, Knaepen PJ, Lensen R, Vermeulen FE. Repeated thromboembolic and bleeding events after mechanical aortic valve replacement. Ann Thorac Surg 2001;71:1172-80. [PMID: 11308155 DOI: 10.1016/s0003-4975(00)02683-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
11
Lund O, Nielsen SL, Arildsen H, Ilkjaer LB, Pilegaard HK. Standard aortic St. Jude valve at 18 years: performance profile and determinants of outcome. Ann Thorac Surg 2000;69:1459-65. [PMID: 10881823 DOI: 10.1016/s0003-4975(00)01191-7] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA