1
|
Sakatani T, Kasahara T, Irie D, Tsubakimoto Y, Matsuo A, Fujita H, Inoue K. Prognostic value of left ventricular mechanical dyssynchrony induced by exercise stress in patients with normal myocardial perfusion single-photon emission computed tomography. J Nucl Cardiol 2022; 29:1-10. [PMID: 33083982 DOI: 10.1007/s12350-020-02389-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2020] [Accepted: 09/17/2020] [Indexed: 11/28/2022]
Abstract
BACKGROUND Left ventricular mechanical dyssynchrony (LVMD) induced by exercise stress was reported to be clinically useful in detecting multivessel coronary artery diseases. The aim of this study was to compare the prognostic value of LVMD induced by pharmacological stress with that induced by exercise stress. METHODS We retrospectively examined 918 consecutive patients who underwent exercise (N = 310) or pharmacological stress (N = 608) 99mTc-tetrofosmin single-photon emission computed tomography (SPECT) with normal myocardial perfusion. LVMD was evaluated by phase analysis as the indices of phase bandwidth and phase standard deviation (PSD). RESULTS During the follow-up period (2.2 ± 1.9 years), 74 major cardiac events (MCEs) occurred (7 cases of cardiac death, 17 cases of heart failure, and 50 cases of coronary intervention). In global patients, the indices of LVMD on rest images were significantly greater in patients with MCEs (bandwidth (°): 51 ± 31 vs 37 ± 21, P = .001, PSD: 14 ± 9 vs 10 ± 6, P = .001). The exercise stress bandwidth was significantly higher in patients with MCEs (62 ± 37° vs 42 ± 21°, P = .026), as was the pharmacological stress bandwidth (57 ± 35° vs 43 ± 24°, P = .006). Multivariate analysis demonstrated the exercise stress bandwidth to be an independent predictor of MCEs (HR 1.017, CI 1.003 to 1.032, P = .019), but the pharmacological stress bandwidth had no influence on MCEs. CONCLUSIONS LVMD induced by exercise stress was an independent predictor of MCEs in patients with normal perfusion SPECT, whereas that induced by pharmacological stress had no association with further events.
Collapse
Affiliation(s)
- Tomohiko Sakatani
- Department of Cardiology, Japanese Red Cross Kyoto Daini Hospital, 355-5 Haruobi-Cho, Kamigyo-Ku, Kyoto, 602-8026, Japan.
| | - Takeru Kasahara
- Department of Cardiology, Japanese Red Cross Kyoto Daini Hospital, 355-5 Haruobi-Cho, Kamigyo-Ku, Kyoto, 602-8026, Japan
| | - Daisuke Irie
- Department of Cardiology, Japanese Red Cross Kyoto Daini Hospital, 355-5 Haruobi-Cho, Kamigyo-Ku, Kyoto, 602-8026, Japan
| | - Yoshinori Tsubakimoto
- Department of Cardiology, Japanese Red Cross Kyoto Daini Hospital, 355-5 Haruobi-Cho, Kamigyo-Ku, Kyoto, 602-8026, Japan
| | - Akiko Matsuo
- Department of Cardiology, Japanese Red Cross Kyoto Daini Hospital, 355-5 Haruobi-Cho, Kamigyo-Ku, Kyoto, 602-8026, Japan
| | - Hiroshi Fujita
- Department of Cardiology, North Medical Center, Kyoto Prefectural University of Medicine, 481 Otokoyama, Yosano-cho, Kyoto, 629-2261, Japan
| | - Keiji Inoue
- Department of Cardiology, Japanese Red Cross Kyoto Daini Hospital, 355-5 Haruobi-Cho, Kamigyo-Ku, Kyoto, 602-8026, Japan
| |
Collapse
|
2
|
Schindler TH, Leucker T. Revival of an old stressor: Dobutamine-stimulation for PET myocardial perfusion imaging in patients with end-stage liver disease? J Nucl Cardiol 2020; 27:2060-2062. [PMID: 30515744 DOI: 10.1007/s12350-018-01543-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2018] [Accepted: 11/20/2018] [Indexed: 10/27/2022]
Affiliation(s)
- Thomas H Schindler
- Division of Nuclear Medicine, Mallinckrodt Institute of Radiology, Washington University School of Medicine, 510 S. Kingshighway, St. Louis, MO, 63110, USA.
| | - Thorsten Leucker
- Division of Cardiology, Department of Medicine, Johns Hopkins University, Baltimore, MD, USA
| |
Collapse
|
3
|
Short-duration, submaximal intensity exercise stress combined with adenosine triphosphate decreases artifacts in myocardial perfusion single-photon emission computed tomography. BMC Cardiovasc Disord 2020; 20:438. [PMID: 33028207 PMCID: PMC7542686 DOI: 10.1186/s12872-020-01720-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Accepted: 09/30/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Myocardial perfusion single-photon emission computed tomography (SPECT) imaging with stress is a useful examination for detecting coronary artery disease. Since the presence of artifacts is remaining challenges, we aimed to define the minimum intensity of low-grade exercise stress levels combined with drug stress to reduce undesired artifacts and their related factors. METHODS We divided patients with suspicious coronary artery disease into 4 groups as follows: group A, adenosine triphosphate (ATP) for 6 min; group A + 25 W, ATP + 25 W exercise for 6 min; group A + 35 W, ATP + 35 W exercise for 6 min; group A + 45 W, ATP + 45 W exercise for 6 min) and enrolled only those whose summed stress scores were < 3. Undesired artifacts were evaluated on the basis of heart-to-liver activity (H/L) ratio and heart-to-10 pixels below the heart (H/below the H) ratio. RESULTS The logarithmic values of H/L and H/below the H ratios were significantly higher in groups A + 35 W and A + 45 W than in group A (p < 0.05, each). In all the patients, the logarithmic values of H/L and H/below the H ratios positively correlated with the increment of rate pressure product (RPP, p = 0.002 and p = 0.005, respectively) after stress in the univariate analysis. The left ventricular end-diastolic volume (LVEDV) after stress (p = 0.002) negatively correlated with the logarithmic value of H/below the H ratio, but not H/L ratio. Although the increment of RPP was independently associated with the logarithmic values of both H/L (p = 0.001) and H/below the H ratios (p = 0.005), LVEDV was also independently associated with the logarithmic value of H/below the H ratio (p < 0.001) in multivariate regression analysis under adjusting with age and sex. CONCLUSION ATP plus ≥35 W exercise stress for 6 min was useful for reducing undesired artifacts after stress in myocardial perfusion SPECT. LVEDV after stress in addition to the increment of RPP was independently associated with the H/below the H ratio, but not the H/L ratio.
Collapse
|
4
|
Molavipordanjani S, Abedi SM, Hosseinimehr SJ, Fatahian A, Mardanshahi A. The effects of pharmacological interventions, exercise, and dietary supplements on extra-cardiac radioactivity in myocardial perfusion single-photon emission computed tomography imaging. Nucl Med Commun 2020; 41:841-847. [PMID: 32796471 DOI: 10.1097/mnm.0000000000001226] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Myocardial perfusion imaging (MPI) as an imaging modality plays a key role in the monitoring of patients with cardiovascular disease. MPI enables the assessment of cardiovascular disease, the effectiveness of therapy, and viable myocardial tissue. However, MPI suffers from some downfalls and limitations, which can influence its clinical applications. These limitations can arise from the patient's condition, equipment, or the actions of the technologist. In this review, we mainly focused on the different effective parameters on radioactivity uptake of organs including liver, intestines, stomach, and gall bladder and how they affect the quality of the acquired images in nuclear medicine. More importantly, we cover how different suggested medicines, foods and exercise alleviative this problem.
Collapse
Affiliation(s)
- Sajjad Molavipordanjani
- Department of Radiology and Nuclear Medicine, Faculty of Medicine, Mazandaran University of Medical Sciences
| | - Seyed Mohammad Abedi
- Department of Radiology and Nuclear Medicine, Faculty of Medicine, Mazandaran University of Medical Sciences
| | - Seyed Jalal Hosseinimehr
- Department of Radiopharmacy, Faculty of Pharmacy, Pharmaceutical Sciences Research Center, Mazandaran University of Medical Sciences
| | - Alireza Fatahian
- Department of Cardiology, Faculty of Medicine, Mazandaran University of Medical Sciences, Sari, Iran
| | - Alireza Mardanshahi
- Department of Radiology and Nuclear Medicine, Faculty of Medicine, Mazandaran University of Medical Sciences
| |
Collapse
|
5
|
Iiya M, Shimizu M, Fujii H, Suzuki M, Nishizaki M. True complete left bundle branch block reveals dyssynchrony evaluated by semiconductor single-photon emission computed tomography. J Arrhythm 2019; 35:70-78. [PMID: 30805046 PMCID: PMC6373645 DOI: 10.1002/joa3.12148] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2018] [Revised: 11/02/2018] [Accepted: 11/19/2018] [Indexed: 12/02/2022] Open
Abstract
BACKGROUND Conventional complete left bundle branch block (CLBBB) criteria sometimes result in a false-positive diagnosis that does not represent dyssynchrony. Recently, true CLBBB criteria have been proposed to detect responders to cardiac resynchronization therapy (CRT), although their correlation with severity of dyssynchrony or natural prognosis is unclear. METHODS Ninety-four consecutive patients (74 ± 9 years, 63 men) with conventional CLBBB during sinus rhythm underwent semiconductor SPECT. They were divided into two groups: patients with true CLBBB and others. True CLBBB was characterized by the mid-QRS notching/slurring and wide QRS duration (male, ≥140 milliseconds; female, ≥130 milliseconds). Multivariate analysis was performed to detect left ventricular dyssynchrony (LVD), defined as bandwidth ≥145° and/or phase standard deviation (SD) ≥43°. Primary endpoints (hospitalization for heart failure or cardiac death) were evaluated. RESULTS True CLBBB had wider bandwidth (145 ± 83° vs 110 ± 64°, P = 0.024) and higher phase SD (48 ± 26° vs 35 ± 19°, P = 0.007). Ejection fraction (EF), end-diastolic volume (EDV), summed rest score (SRS), and the presence of ischemic heart disease (IHD) showed no differences between groups (P = 0.401, 0.591, 0.165, and 0.212, respectively). Multivariate analysis revealed that true CLBBB, EF, and EDV were significant predictors of LVD (odds ratio, 12.6, 0.90, 1.03; P = 0.003, 0.002, 0.022, respectively). At 3-year follow-up (median 667 days), primary endpoints were comparable in both groups (log-rank, P = 0.92). CONCLUSIONS Patients with true CLBBB had more severe dyssynchrony on single-photon emission computed tomography than patients with nontrue CLBBB. On the other hand, the two groups showed no differences in EF, EDV, the presence of IHD, hospitalization for heart failure, and cardiac death.
Collapse
Affiliation(s)
- Munehiro Iiya
- Department of CardiologyYokohama Minami Kyosai HospitalYokohamaJapan
| | - Masato Shimizu
- Department of CardiologyYokohama Minami Kyosai HospitalYokohamaJapan
| | - Hiroyuki Fujii
- Department of CardiologyYokohama Minami Kyosai HospitalYokohamaJapan
| | - Makoto Suzuki
- Department of CardiologyYokohama Minami Kyosai HospitalYokohamaJapan
| | | |
Collapse
|
6
|
Aggarwal NR, Drozdova A, Askew JW, Kemp BJ, Chareonthaitawee P. Feasibility and diagnostic accuracy of exercise treadmill nitrogen-13 ammonia PET myocardial perfusion imaging of obese patients. J Nucl Cardiol 2015; 22:1273-80. [PMID: 25777780 DOI: 10.1007/s12350-015-0073-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2014] [Accepted: 01/04/2015] [Indexed: 10/23/2022]
Abstract
BACKGROUND Treadmill exercise nitrogen-13 ((13)N)-ammonia positron emission tomography (PET) has logistical challenges and limited literature. We aimed to assess its feasibility, image quality, and diagnostic accuracy in obese and nonobese patients. METHODS AND RESULTS Between 2009 and 2012, 10,804 patients were referred for myocardial perfusion imaging, including 300 for treadmill PET, of whom 265 were included in this study. Treadmill testing and PET were performed using standard procedures. Image quality, perfusion, and summed stress score (SSS) were assessed. Invasive coronary angiography was performed within 90 days of PET in 43 patients. Mean ± SD body mass index (BMI) was 35.7 ± 7.7 kg/m(2) (range 19.5-63.5 kg/m(2)). Feasibility of treadmill (13)N-ammonia PET was 100%. Exercise duration was less for obese patients than nonobese patients (P < .001). Image quality was rated good for 96.9% of obese and 100% of nonobese patients. For all patients, sensitivity was 86.4% and specificity was 74.4%. Diagnostic accuracy did not change significantly with increasing BMI. SSS remained significant in predicting angiographic coronary artery disease after adjustment for age, sex, and Duke treadmill score. CONCLUSIONS Treadmill (13)N-ammonia PET is highly feasible, yields good image quality, and has moderately high diagnostic accuracy in a small subset of obese and nonobese patients who are deemed able to perform treadmill exercise.
Collapse
Affiliation(s)
- Niti R Aggarwal
- Division of Cardiovascular Diseases, Mayo Clinic, 200 First St SW, Rochester, MN, 55905, USA
| | - Adela Drozdova
- International Clinical Research Center - Center of Molecular Imaging, St. Anne's University Hospital Brno, Brno, Czech Republic
| | - J Wells Askew
- Division of Cardiovascular Diseases, Mayo Clinic, 200 First St SW, Rochester, MN, 55905, USA
| | - Bradley J Kemp
- Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN, 55905, USA
| | | |
Collapse
|
7
|
Shimizu M, Fujii H, Yamawake N, Nishizaki M. Cardiac function changes with switching from the supine to prone position: analysis by quantitative semiconductor gated single-photon emission computed tomography. J Nucl Cardiol 2015; 22:301-7. [PMID: 25614336 DOI: 10.1007/s12350-014-0058-3] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2013] [Accepted: 06/02/2014] [Indexed: 11/25/2022]
Abstract
BACKGROUND Prone positioning is required in certain operations such as spinal surgery. Changes in cardiac function in the prone position have been studied with various methodologies. Few studies have investigated changes in left ventricular diastolic function and rhythm in subjects turned prone. METHODS AND RESULTS Cardiac function was evaluated in the supine and prone positions in 90 patients without atrial fibrillation who underwent (99m)Tc-tetrofosmin quantitative gated single-photon emission computed tomography. Three groups of 30 patients each were classified as "no history of myocardial ischemia or cardiomyopathy" (Group A), "history of myocardial infarction" (Group B), and "ischemic heart disease without myocardial infarction history" (Group C). Upon assuming the prone position, the cardiac index and any dyssynchrony worsened in all groups. Ejection fraction changes occurred only in Group B, and diastolic function changes occurred in Groups B and C, but not in Group A. The changes caused by prone positioning were more severe in the patients with poor cardiac function. CONCLUSIONS Prone positioning induces significant changes in systolic and diastolic function, as well as dyssynchrony. The negative effects of prone positioning are more severe in patients with poor baseline cardiac function.
Collapse
Affiliation(s)
- Masato Shimizu
- Department of Cardiology, Yokohama Minami Kyosai Hospital, Yokohama, Japan,
| | | | | | | |
Collapse
|
8
|
Pharmacologic manipulation of coronary vascular physiology for the evaluation of coronary artery disease. Pharmacol Ther 2013; 140:121-32. [DOI: 10.1016/j.pharmthera.2013.06.004] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2013] [Accepted: 05/23/2013] [Indexed: 11/24/2022]
|
9
|
Vasu S, Bandettini WP, Hsu LY, Kellman P, Leung S, Mancini C, Shanbhag SM, Wilson J, Booker OJ, Arai AE. Regadenoson and adenosine are equivalent vasodilators and are superior than dipyridamole- a study of first pass quantitative perfusion cardiovascular magnetic resonance. J Cardiovasc Magn Reson 2013; 15:85. [PMID: 24063278 PMCID: PMC3851492 DOI: 10.1186/1532-429x-15-85] [Citation(s) in RCA: 65] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2012] [Accepted: 09/19/2013] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Regadenoson, dipyridamole and adenosine are commonly used vasodilators in myocardial perfusion imaging for the detection of obstructive coronary artery disease. There are few comparative studies of the vasodilator properties of regadenoson, adenosine and dipyridamole in humans. The specific aim of this study was to determine the relative potency of these three vasodilators by quantifying stress and rest myocardial perfusion in humans using cardiovascular magnetic resonance (CMR). METHODS Fifteen healthy normal volunteers, with Framingham score less than 1% underwent vasodilator stress testing with regadenoson (400 μg bolus), dipyridamole (0.56 mg/kg) and adenosine (140 μg /kg/min) on separate days. Rest perfusion imaging was performed initially. Twenty minutes later, stress imaging was performed at peak vasodilation, i.e. 70 seconds after regadenoson, 4 minutes after dipyridamole infusion and between 3-4 minutes of the adenosine infusion. Myocardial blood flow (MBF) in ml/min/g and myocardial perfusion reserve (MPR) were quantified using a fully quantitative model constrained deconvolution. RESULTS Regadenoson produced higher stress MBF than dipyridamole and adenosine (3.58 ± 0.58 vs. 2.81 ± 0.67 vs. 2.78 ± 0.61 ml/min/g, p = 0.0009 and p = 0.0008 respectively). Regadenoson had a much higher heart rate response than adenosine and dipyridamole respectively (95 ± 11 vs. 76 ± 13 vs. 86 ± 12 beats/ minute) When stress MBF was adjusted for heart rate, there were no differences between regadenoson and adenosine (37.8 ± 6 vs. 36.6 ± 4 μl/sec/g, p = NS), but differences between regadenoson and dipyridamole persisted (37.8 ± 6 vs. 32.6 ± 5 μl/sec/g, p = 0.03). The unadjusted MPR was higher with regadenoson (3.11 ± 0.63) when compared with adenosine (2.7 ± 0.61, p = 0.02) and when compared with dipyridamole (2.61 ± 0.57, p = 0.04). Similar to stress MBF, these differences in MPR between regadenoson and adenosine were abolished when adjusted for heart rate (2.04 ± 0.34 vs. 2.12 ± 0.27, p = NS), but persisted between regadenoson and dipyridamole (2.04 ± 0.34 vs. 1.77 ± 0.33, p = 0.07) and between adenosine and dipyridamole (2.12 ± 0.27 vs. 1.77 ± 0.33, p = 0.01). CONCLUSIONS Based on fully quantitative perfusion using CMR, regadenoson and adenosine have similar vasodilator efficacy and are superior to dipyridamole.
Collapse
Affiliation(s)
- Sujethra Vasu
- Section of Cardiology, Wake Forest University School of Medicine, Medical Center Blvd, Winston-Salem, NC, USA
| | - W Patricia Bandettini
- Cardiovascular and Pulmonary Branch, National Heart, Lung and Blood Institute, National Institutes of Health, Department of Health and Human Services, 10 Center Drive, Building 10, Room B1D416, 20892-1061 Bethesda, MD, USA
| | - Li-Yueh Hsu
- Cardiovascular and Pulmonary Branch, National Heart, Lung and Blood Institute, National Institutes of Health, Department of Health and Human Services, 10 Center Drive, Building 10, Room B1D416, 20892-1061 Bethesda, MD, USA
| | - Peter Kellman
- Cardiovascular and Pulmonary Branch, National Heart, Lung and Blood Institute, National Institutes of Health, Department of Health and Human Services, 10 Center Drive, Building 10, Room B1D416, 20892-1061 Bethesda, MD, USA
| | - Steve Leung
- Cardiovascular and Pulmonary Branch, National Heart, Lung and Blood Institute, National Institutes of Health, Department of Health and Human Services, 10 Center Drive, Building 10, Room B1D416, 20892-1061 Bethesda, MD, USA
| | - Christine Mancini
- Cardiovascular and Pulmonary Branch, National Heart, Lung and Blood Institute, National Institutes of Health, Department of Health and Human Services, 10 Center Drive, Building 10, Room B1D416, 20892-1061 Bethesda, MD, USA
| | - Sujata M Shanbhag
- Cardiovascular and Pulmonary Branch, National Heart, Lung and Blood Institute, National Institutes of Health, Department of Health and Human Services, 10 Center Drive, Building 10, Room B1D416, 20892-1061 Bethesda, MD, USA
| | - Joel Wilson
- Cardiovascular and Pulmonary Branch, National Heart, Lung and Blood Institute, National Institutes of Health, Department of Health and Human Services, 10 Center Drive, Building 10, Room B1D416, 20892-1061 Bethesda, MD, USA
| | | | - Andrew E Arai
- Cardiovascular and Pulmonary Branch, National Heart, Lung and Blood Institute, National Institutes of Health, Department of Health and Human Services, 10 Center Drive, Building 10, Room B1D416, 20892-1061 Bethesda, MD, USA
| |
Collapse
|
10
|
Advances in Cardiac SPECT and PET Imaging: Overcoming the Challenges to Reduce Radiation Exposure and Improve Accuracy. Can J Cardiol 2013; 29:275-84. [DOI: 10.1016/j.cjca.2012.10.003] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2012] [Revised: 09/27/2012] [Accepted: 10/04/2012] [Indexed: 11/22/2022] Open
|
11
|
Trägårdh E, Sjöstrand K, Edenbrandt L. Normal stress databases in myocardial perfusion scintigraphy--how many subjects do you need? Clin Physiol Funct Imaging 2012; 32:455-62. [PMID: 23031066 DOI: 10.1111/j.1475-097x.2012.01149.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2011] [Accepted: 06/08/2012] [Indexed: 11/28/2022]
Abstract
BACKGROUND Commercial normal stress databases in myocardial perfusion scintigraphy (MPS) commonly consist of 30-40 individuals. The aim of the study was to determine how many subjects are needed. METHODS Four normal stress databases were developed using patients who underwent 99mTc MPS: non-corrected images (NC) for male, NC for female, attenuation-corrected images (AC) for male and AC for female subjects. 126 male and 205 female subjects were included. The normal database was created by alternatingly computing the mean of all normal subjects and normalizing the subjects with respect to this mean, until convergence. Coefficients of variation (CV) were created for increasing number of included patients in the four different normal stress databases. RESULTS Normal stress databases with < 35 subjects had a high CV. Mean CV -2 standard deviations (SD) decreased with 28% between two and five included subjects, 71% between two and 35 subjects and 83% between two and 100 included subjects for NC man. CONCLUSIONS We conclude that the commonly used 30-40 individuals for making a normal stress database might not be enough due to the high CV. We propose that normal stress databases should consist of more than 30-40 individuals, preferably more than 50 individuals, both for NC and AC studies.
Collapse
Affiliation(s)
- Elin Trägårdh
- Clinical Physiology and Nuclear Medicine Unit, Skåne University Hospital, Lund University, Malmö, Sweden
| | | | | |
Collapse
|
12
|
Fatima N, Uz Zaman M, Ishaq M, Rasheed SZ, Baloch DJ, Wali A, Bano J, Rehman K. Higher events rate in patients with a normal gated myocardial perfusion imaging with dipyridamole than exercise: "Run for reliability". INDIAN JOURNAL OF NUCLEAR MEDICINE : IJNM : THE OFFICIAL JOURNAL OF THE SOCIETY OF NUCLEAR MEDICINE, INDIA 2012; 27:172-5. [PMID: 23919070 PMCID: PMC3728738 DOI: 10.4103/0972-3919.112722] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
OBJECTIVE The aim of this is to evaluate the negative predictive value (NPV) of a normal gated myocardial perfusion imaging (NGMPI) with exercise and dipyridamole in a propensity matched population. MATERIALS AND METHODS This is a prospective study conducted at Nuclear Cardiology Department of Karachi Institute of Heart Diseases, Karachi from December 2008 until June 2010. A total of 809 patients with a NGMPI with adequate exercise (558/809) or dipyridamole (251/809) stress were included and followed-up for 12-30 months (mean 24 ± 3 months) for fatal or non-fatal myocardial infarctions (MI). RESULTS Mean ejection fraction (%), end diastolic volume (ml), and end systolic volume (ml) in exercise and dipyridamole cohorts were (72 ± 08, 66 ± 11), (68 ± 13, 81 ± 17), and (19 ± 11, 26 ± 12) respectively. On follow-up, in dipyridamole cohort 2 fatal and 6 non-fatal MIs were reported. While in exercise cohort only 2 non-fatal MIs were reported. The NPV of a NGMPI with exercise was 99.7% (95% confidence interval [CI] 98.93-99.96%) with an event rate of 0.3% (95% CI; 0.03-0.6%) and annualized event rate of 0.15%. The NPV of NGMPI with dipyridamole was 96.80% (95% CI; 2.2-4.3%) with an event rate of 3.2% (95% CI; 1.39-3.83%) and annualized event rate of approximately 1.6%. Event free survival for dipyridamole group was significantly lower than exercise analyzed by Log-rank test (14.509, P < 0.001). CONCLUSION A NGMPI with dipyridamole stress has higher event rate (low-NPV) as compared with exercise and this raises concern over its credibility to label these patients into low-risk group.
Collapse
Affiliation(s)
- Nosheen Fatima
- Department of Nuclear Cardiology, Karachi Institute of Heart Diseases, Karachi, Pakistan ; Department of Nuclear Medicine, Dr Ziauddin Medical University, Karachi, Pakistan
| | | | | | | | | | | | | | | |
Collapse
|
13
|
Techasith T, Cury RC. Stress myocardial CT perfusion: an update and future perspective. JACC Cardiovasc Imaging 2011; 4:905-16. [PMID: 21835384 DOI: 10.1016/j.jcmg.2011.04.017] [Citation(s) in RCA: 72] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2011] [Revised: 03/31/2011] [Accepted: 04/07/2011] [Indexed: 10/17/2022]
Abstract
Coronary computed tomography angiography (CTA) has been shown by several multicenter trials to have excellent diagnostic accuracy in the detection and exclusion of significant coronary stenosis. However, a major limitation of coronary CTA is that the physiological significance of stenotic lesions identified is often unknown. Stress myocardial computed tomography perfusion (CTP) is a novel examination that provides both anatomic and physiological information (i.e., myocardial perfusion). Multiple single-center studies have established the feasibility of stress myocardial CTP. Furthermore, it has been illustrated that a combined CTA/CTP protocol improves the diagnostic accuracy to detect hemodynamic significant stenosis as compared with CTA alone; this combined protocol can also be accomplished at a radiation dose comparable to nuclear myocardial perfusion imaging exams. Although initial results hold some promise, stress myocardial CTP is a modality in its infancy. Further research is required to define, validate, and optimize this new technique. However, it is a modality with significant potential, particularly in the evaluation of chest pain patients, given the advantages of short exam time and comprehensive data acquisition. This review highlights how to perform and interpret stress myocardial CTP, summarizes the current literature, and discusses some future directions.
Collapse
|
14
|
Rischpler C, Park MJ, Fung GSK, Javadi M, Tsui BMW, Higuchi T. Advances in PET myocardial perfusion imaging: F-18 labeled tracers. Ann Nucl Med 2011; 26:1-6. [PMID: 22069195 DOI: 10.1007/s12149-011-0552-5] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2011] [Accepted: 10/23/2011] [Indexed: 11/29/2022]
Abstract
Coronary artery disease and its related cardiac disorders represent the most common cause of death in the USA and Western world. Despite advancements in treatment and accompanying improvements in outcome with current diagnostic and therapeutic modalities, it is the correct assignment of these diagnostic techniques and treatment options which are crucial. From a diagnostic standpoint, SPECT myocardial perfusion imaging (MPI) using traditional radiotracers like thallium-201 chloride, Tc-99m sestamibi or Tc-99m tetrofosmin is the most utilized imaging technique. However, PET MPI using N-13 ammonia, rubidium-82 chloride or O-15 water is increasing in availability and usage as a result of the growing number of medical centers with new-generation PET/CT systems taking advantage of the superior imaging properties of PET over SPECT. The routine clinical use of PET MPI is still limited, in part because of the short half-life of conventional PET MPI tracers. The disadvantages of these conventional PET tracers include expensive onsite production and inconvenient on-scanner tracer administration making them unsuitable for physical exercise stress imaging. Recently, two F-18 labeled radiotracers with longer radioactive half-lives than conventional PET imaging agents have been introduced. These are flurpiridaz F 18 (formerly known as F-18 BMS747158-02) and F-18 fluorobenzyltriphenylphosphonium. These longer half-life F-18 labeled perfusion tracers can overcome the production and protocol limitations of currently used radiotracers for PET MPI.
Collapse
Affiliation(s)
- Christoph Rischpler
- Nuklearmedizinische Klinik und Poliklinik, Klinikum rechts der Isar, Technische Universität München, Munich, Germany
| | | | | | | | | | | |
Collapse
|
15
|
Rozanski A, Gransar H, Hayes SW, Friedman JD, Hachamovitch R, Berman DS. Comparison of long-term mortality risk following normal exercise vs adenosine myocardial perfusion SPECT. J Nucl Cardiol 2010; 17:999-1008. [PMID: 21076898 PMCID: PMC2990006 DOI: 10.1007/s12350-010-9300-9] [Citation(s) in RCA: 76] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2010] [Accepted: 09/28/2010] [Indexed: 12/01/2022]
Abstract
BACKGROUND A higher frequency of clinical events has been observed in patients undergoing pharmacological vs exercise myocardial perfusion single-photon emission computed tomography (SPECT). While this difference is attributed to greater age and co-morbidities, it is not known whether these tests also differ in prognostic ability among patients with similar clinical profiles. METHODS AND RESULTS We assessed all-cause mortality rates in 6,069 patients, followed for 10.2 ± 1.7 years after undergoing exercise or adenosine SPECT. We employed propensity analysis to match exercise and adenosine subgroups by age, gender, symptoms, and coronary risk factors. Within our propensity-matched cohorts, adenosine patients had an annualized mortality rate event rates that was more than twice that of exercise patients (3.9% vs 1.6%, P < .0001). Differences in mortality persisted among age groups, including those <55 years old. In the exercise cohort, mortality was inversely related to exercise duration, with comparable mortality noted for patients exercising <3 min and those undergoing adenosine testing. CONCLUSIONS Among patients with normal stress SPECT tests, those undergoing adenosine testing manifest a mortality rate that is substantially higher than that observed among adequately exercising patients, but comparable to that observed among very poorly exercising patients. This elevated risk underscores an important challenge for managing patients undergoing pharmacological stress testing.
Collapse
Affiliation(s)
- Alan Rozanski
- Division of Cardiology, St. Lukes Roosevelt Hospital, New York, NY USA
| | - Heidi Gransar
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, The Burns and Allen Research Institute, 8700 Beverly Building, Room 1258, Los Angeles, CA 90048 USA
| | - Sean W. Hayes
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, The Burns and Allen Research Institute, 8700 Beverly Building, Room 1258, Los Angeles, CA 90048 USA
- David Geffen School of Medicine, University of California, Los Angeles, CA USA
| | - John D. Friedman
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, The Burns and Allen Research Institute, 8700 Beverly Building, Room 1258, Los Angeles, CA 90048 USA
- David Geffen School of Medicine, University of California, Los Angeles, CA USA
| | - Rory Hachamovitch
- Department of Medicine, University of Southern California, Los Angeles, CA USA
| | - Daniel S. Berman
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, The Burns and Allen Research Institute, 8700 Beverly Building, Room 1258, Los Angeles, CA 90048 USA
- David Geffen School of Medicine, University of California, Los Angeles, CA USA
| |
Collapse
|
16
|
Vasodilatory effect of adenosine triphosphate does not change cerebral blood flow: a PET study with (15)O-water. Ann Nucl Med 2009; 23:717-23. [PMID: 19728018 DOI: 10.1007/s12149-009-0294-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2009] [Accepted: 07/28/2009] [Indexed: 10/20/2022]
Abstract
OBJECTIVE Adenosine triphosphate (ATP) is the parent compound of adenosine and well known as a powerful vasodilator. To investigate the effect of ATP on cerebral blood flow (CBF) and cerebral vessels, (15)O-water positron emission tomography (PET) studies were performed to evaluate changes in CBF and blood volume before and after ATP administration. METHODS Ten healthy young volunteers underwent (15)O-water PET scans under the conditions of baseline, 3 and 1 min after ATP continuous infusion. CBF values in cortical regions of the bilateral middle cerebral arteries and basal ganglia were obtained for each subject. Statistical parametric mapping (SPM) was applied for analysis of regional changes. Physiologic parameters, such as blood gas and blood pressure were also measured. RESULTS Cortical CBF showed no significant change after continuous infusion of ATP compared with the baseline. Dilatation of major vessels induced by ATP was visualized on SPM analysis. Heart rates increased and mean blood pressure decreased during ATP administration while blood gas data showed no changes between the different conditions. CONCLUSIONS Intravenous ATP administration caused dilatation of major cerebral vessels but no significant change in CBF under normoventilation and decrease in systemic blood pressure, indicating that this no change in CBF under vasodilatory effect of ATP may be caused by cerebral microvascular autoregulation.
Collapse
|
17
|
Kaya E, Entok E, Cavusoglu Y, Saglam H, Vardareli E, Timuralp B. SHORT-TERM PROGNOSTIC VALUE OF REST Tc99m-MIBI GATED SPECT AFTER ACUTE NON-Q WAVE MYOCARDIAL INFARCTION. ELECTRONIC JOURNAL OF GENERAL MEDICINE 2008. [DOI: 10.29333/ejgm/82600] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
18
|
Kaya E, Saglam H, Ciftci I, Kulac M, Karaca S, Melek M. Evaluation of myocardial perfusion and function by gated SPECT in patients with Behçet's disease. Ann Nucl Med 2008; 22:287-95. [PMID: 18535879 DOI: 10.1007/s12149-007-0115-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2007] [Accepted: 12/13/2007] [Indexed: 10/22/2022]
Abstract
BACKGROUND Behçet's disease (BD) is a systemic multi-system vasculitis that can have a wide range of effects on the cardiovascular system. OBJECTIVE To determine the existence of myocardial perfusion defects caused by coronary microvascular dysfunction in BD and to evaluate coronary arterial distribution and left ventricular systolic function by gated single-photon emission computed tomography (SPECT). METHODS The study population consisted of 23 (15 men and 8 women) patients with BD and 20 healthy controls (12 men and 8 women). Technetium-99m methoxyisobutylisonitrile (Tc-99m MIBI) gated SPECT studies were performed at stress and rest in a 2-day protocol. Stress and rest left ventricular ejection fraction (LVEF) were calculated. Using non-gated SPECT images myocardial perfusion scores [summed stress score (SSS), summed rest score (SRS), summed difference score (SDS), and fix defect score (FDS)] and perfusion defect extent as percentage (stress, rest ischemic, and fix %LV) were determined. Using gated SPECT images, wall motion score indices (stress wall motion score indices and rest wall motion score indices) were calculated. Coronary angiography (CAG) was applied to patients with abnormal myocardial perfusion scintigraphy (MPS). RESULTS The mean ages of the BD and control groups were 39.3 +/- 10.6 years and 36.2 +/- 8.3 years, respectively. No statistically significant differences were observed between the two groups regarding clinical features and cardiologic findings. Abnormal MPS was found in 13 (56.5%) of the BD patients; 3 patients had non-transmural infarcts and 10 patients reversible perfusion defects. Reversible perfusion defects were also found in two controls (10.0%). When the two groups were compared regarding the gated SPECT findings, differences were determined in the following parameters; SSS, SRS, SDS, FDS, stress and rest LVEF, stress and rest %LV, and stress and rest WMSI. In the BD group, when gated SPECT results were compared between those with and without abnormal MPS, differences were determined in SSS, SRS, SDS, FDS, stress and rest %LV, and stress and rest WMSI. Epicardial coronary arteries were normal in CAG. CONCLUSIONS Myocardial perfusion and function are disturbed owing to influenced coronary microvascularity in BD, and CAG is frequently observed to be normal. Gated SPECT is a non-invasive reliable method that simultaneously evaluates the existence, extent and severity of myocardial ischemia or infarction and the wall movements in cardio-Behçet.
Collapse
Affiliation(s)
- Eser Kaya
- Department of Nuclear Medicine, Faculty of Medicine, Afyon Kocatepe University, Inönü Bulvari, Afyonkarahisar, Turkey.
| | | | | | | | | | | |
Collapse
|
19
|
|
20
|
Xie F, Hankins J, Mahrous HA, Porter TR. Detection of Coronary Artery Disease with a Continuous Infusion of Definity Ultrasound Contrast during Adenosine Stress Real Time Perfusion Echocardiography. Echocardiography 2007; 24:1044-50. [DOI: 10.1111/j.1540-8175.2007.00543.x] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
21
|
Heijenbrok-Kal MH, Fleischmann KE, Hunink MGM. Stress echocardiography, stress single-photon-emission computed tomography and electron beam computed tomography for the assessment of coronary artery disease: a meta-analysis of diagnostic performance. Am Heart J 2007; 154:415-23. [PMID: 17719283 DOI: 10.1016/j.ahj.2007.04.061] [Citation(s) in RCA: 113] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/20/2006] [Accepted: 04/29/2007] [Indexed: 11/29/2022]
Abstract
BACKGROUND Many studies have been published on the diagnostic performance of noninvasive tests for the assessment of coronary artery disease. The objective of the present study was to compare the published literature on the diagnostic performance of stress echocardiography, stress single-photon-emission computed tomography (SPECT), and electron beam computed tomography (EBCT). METHODS Meta-analytic studies on the diagnostic performance of imaging tests for coronary artery disease were searched in the Cochrane Library, PubMed, and bibliographies of selected articles. Sensitivities, specificities, and diagnostic odds ratios of the source studies were calculated per modality. Taking into account differences between studies, a random effects summary receiver operating characteristic analysis was performed. RESULTS We analyzed the data of 351 patient series, which were reported in 11 meta-analyses. The sensitivity of EBCT was significantly higher than that of stress SPECT, which had a significantly higher sensitivity than stress echocardiography (respectively, 93.1% [95% confidence interval, 90.7-95.6], 88.1 [95% confidence interval, 86.6-89.6], and 79.1% [95% confidence interval, 77.6-80.5]). The specificity of stress echocardiography was significantly higher than that of stress SPECT, which had a significantly higher specificity than EBCT (respectively, 87.1% [95% confidence interval, 85.7-88.5], 73.0% [95% confidence interval, 69.1-76.9], and 54.5% [95% confidence interval, 45.3-63.8]). The diagnostic odds ratios did not differ significantly between the 3 modalities, which resulted in one underlying summary receiver operating characteristic curve. CONCLUSIONS This study suggests that there are no significant differences in the overall diagnostic performance between stress echocardiography, stress SPECT, and EBCT for the diagnosis of coronary artery disease. However, differences exist in sensitivity and specificity estimates, which may make each modality useful in different settings.
Collapse
Affiliation(s)
- Majanka H Heijenbrok-Kal
- Department of Epidemiology and Biostatistics, Erasmus MC-University Medical Center Rotterdam, Rotterdam, The Netherlands.
| | | | | |
Collapse
|
22
|
Chun KA, Lee J, Lee SW, Ahn BC, Ha JH, Cho IH, Chae SC, Lee KB. Direct comparison of adenosine and adenosine 5'-triphosphate as pharmacologic stress agents in conjunction with Tl-201 SPECT: Hemodynamic response, myocardial tracer uptake, and size of perfusion defects in the same subjects. J Nucl Cardiol 2006; 13:621-8. [PMID: 16945741 DOI: 10.1016/j.nuclcard.2006.05.021] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2006] [Revised: 05/26/2006] [Accepted: 05/26/2006] [Indexed: 11/18/2022]
Abstract
BACKGROUND Adenosine 5'-triphosphate (ATP), a potent and inexpensive coronary vasodilator, was introduced as a pharmacologic stress agent for thallium 201 single photon emission computed tomography (SPECT). However, there has been no direct comparison of ATP and adenosine as myocardial stressors in the same subjects. METHODS AND RESULTS Thirty-six patients underwent consecutive Tl-201 SPECT imaging with adenosine and ATP in a randomly assigned order. There were no changes in clinical status and no invasive procedures were performed between the two tests. The hemodynamic response and side effects were monitored, and myocardial tracer uptake was assessed by use of a visual grading system and quantitative analysis via a CEqual map. The hemodynamic changes and adverse effects did not differ significantly between the two groups. There were no changes in the detection of any perfusion defect on a per-subject basis, except in one. The exact agreement rate for the visual grading of the myocardial tracer uptake was 84.8%. However, the average extent of the perfusion defect and the severity score were higher with adenosine. CONCLUSION The hemodynamic changes and the degree of myocardial uptake were similar between the adenosine and ATP infusion. However, quantitative analysis by use of a CEqual map revealed smaller perfusion defects and lower severity scores in subjects undergoing Tl-201 SPECT with ATP.
Collapse
Affiliation(s)
- Kyung Ah Chun
- Department of Nuclear Medicine, School of Medicine, Kyungpook National University, Daegu, South Korea
| | | | | | | | | | | | | | | |
Collapse
|
23
|
Zoghbi GJ, Htay T, Aqel R, Blackmon L, Heo J, Iskandrian AE. Effect of Caffeine on Ischemia Detection by Adenosine Single-Photon Emission Computed Tomography Perfusion Imaging. J Am Coll Cardiol 2006; 47:2296-302. [PMID: 16750699 DOI: 10.1016/j.jacc.2005.11.088] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/14/2005] [Revised: 11/02/2005] [Accepted: 11/08/2005] [Indexed: 10/24/2022]
Abstract
OBJECTIVES The purpose of this research was to study the effect of one cup of coffee taken 1 h before adenosine stress on the results of myocardial perfusion imaging. BACKGROUND Caffeine is believed to attenuate the coronary hyperemic response to adenosine by competitive blockade of the A2a receptor. Caffeine is commonly withheld before adenosine single-photon emission computed tomography (SPECT) perfusion imaging so as not to mask ischemia detection. METHODS We studied the effect of one 8-oz cup of coffee taken 1 h before adenosine stress in patients who had demonstrable reversible defects on adenosine SPECT perfusion imaging performed while off caffeine. RESULTS There were 22 men and 8 women, age 64 +/- 9 years. The blood level of caffeine 1 h after intake was 3.1 +/- 1.6 mg/l. There were two patients with ST-segment depression before and one after caffeine intake (p = NS). The summed stress score (SSS) based on 17 segments (scale of 0 to 3, 3 being normal) was 44 +/- 5 before and 45 +/- 5 after caffeine (p = NS). The summed difference score was 3.8 +/- 1.9 before and. 3.9 +/- 2.3 after caffeine (p = NS), reflecting that around 50% of the perfusion abnormality was reversible before and after caffeine. Using polar maps, the perfusion abnormality was 12 +/- 10% at baseline and 12 +/- 10% after caffeine (p = NS) in agreement with SSS. The left ventricular ejection fraction by gated SPECT was 50 +/- 13% at baseline and 51 +/- 13 % after caffeine (p = NS). CONCLUSIONS A cup of coffee does not mask the presence or severity of reversible defects induced by adenosine SPECT imaging.
Collapse
Affiliation(s)
- Gilbert J Zoghbi
- Division of Cardiovascular Disease, University of Alabama at Birmingham, Birmingham, Alabama 35294 , USA.
| | | | | | | | | | | |
Collapse
|
24
|
Chow BJW, Beanlands RS, Lee A, DaSilva JN, deKemp RA, Alkahtani A, Ruddy TD. Treadmill Exercise Produces Larger Perfusion Defects Than Dipyridamole Stress N-13 Ammonia Positron Emission Tomography. J Am Coll Cardiol 2006; 47:411-6. [PMID: 16412870 DOI: 10.1016/j.jacc.2005.09.027] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/05/2005] [Revised: 08/30/2005] [Accepted: 09/08/2005] [Indexed: 11/22/2022]
Abstract
OBJECTIVES The aim of this study was to compare treadmill exercise (TEX) and dipyridamole stress on the uptake and retention of N-13 ammonia. BACKGROUND Size and severity of stress-induced myocardial perfusion defects are clinically important. Because ammonia uptake and retention seems to be related to perfusion, viability, and metabolism, exercise stress might induce larger perfusion defects than dipyridamole stress. METHODS Twenty-six patients underwent TEX and dipyridamole stress N-13 ammonia positron emission tomography (PET). Images were assessed with a 17-segment model and a five-point score. Summed stress score (SSS), summed rest score (SRS), and summed difference score (SDS) were calculated. Left ventricular (LV) defect sizes were measured quantitatively with a 70% threshold for abnormal perfusion. RESULTS Compared with dipyridamole stress, TEX yielded larger SSS (9.1 +/- 5.7 vs. 6.9 +/- 5.9; p < 0.01), SDS (5.8 +/- 4.7 vs. 3.7 +/- 4.6; p < 0.02), and percentage of LV stress defect (19.3 +/- 11.5% vs. 13.8 +/- 13.6%; p < 0.02). CONCLUSIONS In patients achieving adequate exercise, TEX N-13 ammonia PET myocardial perfusion imaging (MPI) yields larger stress perfusion defects than dipyridamole stress and might reflect the true myocardial ischemic burden. Treadmill exercise might be the preferred method of stress for routine N-13 ammonia PET MPI.
Collapse
Affiliation(s)
- Benjamin J W Chow
- Division of Cardiology, University of Ottawa Heart Institute, Ottawa, Ontario, Canada.
| | | | | | | | | | | | | |
Collapse
|
25
|
Miller DD. Impact of selective adenosine A2A receptor agonists on cardiac imaging feeling the lightning, waiting on the thunder. J Am Coll Cardiol 2005; 46:2076-8. [PMID: 16325045 DOI: 10.1016/j.jacc.2005.07.061] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2005] [Revised: 07/20/2005] [Accepted: 07/25/2005] [Indexed: 11/21/2022]
|
26
|
Hendel RC, Bateman TM, Cerqueira MD, Iskandrian AE, Leppo JA, Blackburn B, Mahmarian JJ. Initial clinical experience with regadenoson, a novel selective A2A agonist for pharmacologic stress single-photon emission computed tomography myocardial perfusion imaging. J Am Coll Cardiol 2005; 46:2069-75. [PMID: 16325044 DOI: 10.1016/j.jacc.2005.05.097] [Citation(s) in RCA: 101] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/24/2005] [Revised: 04/24/2005] [Accepted: 05/18/2005] [Indexed: 11/20/2022]
Abstract
OBJECTIVES Regadenoson, a selective A2A adenosine receptor agonist, was evaluated for tolerability and effectiveness as a pharmacological stress agent for detecting reversible myocardial hypoperfusion when combined with single-photon emission computed tomography (SPECT). BACKGROUND Adenosine and dipyridamole are nonselective adenosine agonists currently used as pharmacologic stressors. Despite proven safety, these agents often cause undesirable side effects and require a continuous infusion. METHODS This Phase II, multicenter, open-label trial was conducted in 36 patients who had demonstrated ischemia on a 6-min adenosine SPECT imaging study within the previous 2 to 46 days. Patients received regadenoson as a rapid intravenous bolus dose of 400 microg (n = 18) or 500 microg (n = 18). The radiopharmaceutical was then delivered within one minute. The SPECT images were acquired in a standard manner and uniformly processed at a central laboratory. Regadenoson and adenosine studies were presented in random order and interpreted blindly with a 17-segment model by three observers. Additionally, quantitative analysis was performed with 4D-MSPECT software (University of Michigan, Ann Arbor, Michigan). RESULTS Overall agreement for the presence of reversible hypoperfusion was 86%. The 400-mug dose was better tolerated. Overall, regadenoson was well-tolerated; side effects (e.g., chest discomfort, flushing, dyspnea) were generally mild in severity and self-limiting. High-grade atrioventricular block and bronchospasm were not observed. CONCLUSIONS Regadenoson is well-tolerated and seems as effective as adenosine for detecting and quantifying the extent of hypoperfusion observed with SPECT perfusion imaging. Phase III clinical trials are now underway, given the promise of regadenoson's reduced side effects and simplicity of bolus administration.
Collapse
|
27
|
Sakuma H, Suzawa N, Ichikawa Y, Makino K, Hirano T, Kitagawa K, Takeda K. Diagnostic accuracy of stress first-pass contrast-enhanced myocardial perfusion MRI compared with stress myocardial perfusion scintigraphy. AJR Am J Roentgenol 2005; 185:95-102. [PMID: 15972407 DOI: 10.2214/ajr.185.1.01850095] [Citation(s) in RCA: 88] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The purpose of this study was to determine the diagnostic accuracy of stress perfusion MRI acquired with saturation-recovery prepared turbo fast low-angle shot (turbo FLASH) compared with stress myocardial perfusion scintigraphy. Recent studies show that first-pass contrast-enhanced myocardial perfusion MRI can provide noninvasive detection of low-limiting stenosis in the coronary artery. MATERIALS AND METHODS First-pass contrast-enhanced MR images were acquired at rest and during stress in 40 patients with suspected coronary artery disease. All patients underwent thallium-201 SPECT without attenuation correction and coronary angiography. Two reviewers independently assigned one of five confidence grades without knowing the results of coronary angiography for receiver operating characteristic (ROC) analysis. Luminal stenosis >70% on coronary angiography was used as a reference standard. RESULTS On coronary angiography, 70% or greater diameter stenosis of the coronary artery was observed in 21 (52.5%) of 40 patients. The areas under the ROC curve for detection of significant stenosis in the individual coronary artery were 0.86 (observer 1) and 0.84 (observer 2) for MRI. These values were 0.79 (observer 1, p = not significant) and 0.72 (observer 2, p = not significant) for 201Tl SPECT. CONCLUSION The diagnostic accuracy of stress perfusion MRI acquired with saturation-recovery-prepared turbo FLASH was comparable with that of stress 201Tl SPECT. Stress first-pass contrast-enhanced MRI is a noninvasive technique that can be used as an alternative to stress myocardial perfusion scintigraphy.
Collapse
Affiliation(s)
- Hajime Sakuma
- Department of Radiology, Mie University Hospital, 2-174 Edobashi, Tsu, Mie 514-8507, Japan.
| | | | | | | | | | | | | |
Collapse
|
28
|
Salm LP, Bax JJ, Vliegen HW, Langerak SE, Dibbets P, Jukema JW, Lamb HJ, Pauwels EKJ, de Roos A, van der Wall EE. Functional significance of stenoses in coronary artery bypass grafts. Evaluation by single-photon emission computed tomography perfusion imaging, cardiovascular magnetic resonance, and angiography. J Am Coll Cardiol 2005; 44:1877-82. [PMID: 15519022 DOI: 10.1016/j.jacc.2004.07.048] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/11/2004] [Revised: 07/16/2004] [Accepted: 07/29/2004] [Indexed: 10/26/2022]
Abstract
OBJECTIVES This study was designed to perform a head-to-head comparison between single-photon emission computed tomography (SPECT) and cardiovascular magnetic resonance (CMR) to evaluate hemodynamic significance of angiographic findings in bypass grafts. BACKGROUND The hemodynamic significance of a bypass graft stenosis may not always accurately be determined from the coronary angiogram. A variety of diagnostic tests (invasive or noninvasive) can further characterize the hemodynamic consequence of a lesion. METHODS Fifty-seven arterial and vein grafts in 25 patients were evaluated by angiography, SPECT perfusion imaging, and coronary flow velocity reserve determination by CMR. Based on angiography and SPECT, four different groups could be identified: 1) no significant stenosis (<50%), normal perfusion; 2) significant stenosis (>/=50%), abnormal perfusion; 3) significant stenosis, normal perfusion (no hemodynamic significance); and 4) no significant stenosis, abnormal perfusion (suggesting microvascular disease). RESULTS A complete evaluation was obtained in 46 grafts. Single-photon emission computed tomography and CMR provided similar information in 37 of 46 grafts (80%), illustrating good agreement (kappa = 0.61, p < 0.001). Eight grafts perfused a territory with scar tissue. When agreement between SPECT and CMR was restricted to grafts without scar tissue, it improved to 84% (kappa = 0.68). Integration of angiography with SPECT categorized 14 lesions in group 1, 23 in group 2, 6 in group 3, and 3 in group 4. Single-photon emission computed tomography and CMR agreement per group was 86%, 78%, 100%, and 33%, respectively. CONCLUSIONS Head-to-head comparison showed good agreement between SPECT and CMR for functional evaluation of bypass grafts. Cardiovascular magnetic resonance may offer an alternative method to SPECT for functional characterization of angiographic lesions.
Collapse
Affiliation(s)
- Liesbeth P Salm
- Department of Cardiology, Interuniversity Cardiology Institute of the Netherlands, Utrecht, The Netherlands
| | | | | | | | | | | | | | | | | | | |
Collapse
|
29
|
Ishida N, Sakuma H, Motoyasu M, Okinaka T, Isaka N, Nakano T, Takeda K. Noninfarcted myocardium: correlation between dynamic first-pass contrast-enhanced myocardial MR imaging and quantitative coronary angiography. Radiology 2003; 229:209-16. [PMID: 12944596 DOI: 10.1148/radiol.2291021118] [Citation(s) in RCA: 159] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To determine the accuracy of first-pass contrast material-enhanced stress myocardial magnetic resonance (MR) imaging for depiction of myocardial ischemia in patients without myocardial infarction. MATERIALS AND METHODS First-pass contrast-enhanced MR images of the entire left ventricle were acquired in 104 patients at rest and during dipyridamole-induced stress by using an interleaved notched saturation technique. Coronary angiography was performed in all patients, and stress perfusion single photon emission computed tomography (SPECT) was performed in 69 patients. Receiver operating characteristic curve analysis was performed to compare the diagnostic accuracies of first-pass contrast-enhanced stress MR imaging and stress SPECT, with coronary angiography as the reference standard. RESULTS The overall sensitivity of MR imaging for depicting at least one coronary artery with significant stenosis was 90% (69 of 77 patients). The sensitivities of MR imaging for depiction of single-, double-, and triple-vessel stenoses were 85% (33 of 39 patients), 96% (22 of 23 patients), and 100% (15 of 15 patients), respectively. The specificity of MR imaging for identification of patients with significant coronary artery stenoses was 85% (23 of 27 patients). The areas under the receiver operating characteristic curve for detection of significant stenosis in individual coronary arteries were 0.888 (observer 1) and 0.911 (observer 2) for MR imaging and 0.707 (observer 1, P <.001) and 0.750 (observer 2, P <.001) for SPECT. CONCLUSION In patients without myocardial infarction, stress enhancement at dynamic MR imaging correlates more closely with quantitative coronary angiography results than does stress enhancement at SPECT.
Collapse
Affiliation(s)
- Nanaka Ishida
- Department of Radiology, Mie University School of Medicine, 2-174 Edobashi, Tsu, Mie 514-8507, Japan
| | | | | | | | | | | | | |
Collapse
|
30
|
Thompson PD, Ahlberg AW, Moyna NM, Duncan B, Ferraro-Borgida M, White CM, McGill CC, Heller GV. Effect of intravenous testosterone on myocardial ischemia in men with coronary artery disease. Am Heart J 2002; 143:249-56. [PMID: 11835027 DOI: 10.1067/mhj.2002.120144] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
BACKGROUND Studies on the effect of estrogen on atherosclerotic coronary artery disease (CAD) risk in women have produced conflicting results. Similar confusion, but fewer data, exists on the effect of testosterone on CAD risk in men. METHODS We used 99mTc sestamibi single-photon emission computed tomography (SPECT) myocardial perfusion imaging to examine the acute effect of intravenous testosterone in 32 men (mean age, 69.1 +/- 6.4 years) with provocable myocardial ischemia on standard medical therapy. Patients performed 3 exercise (n = 18) or adenosine (n = 16) stress tests during the infusion of placebo or 2 doses of testosterone designed to increase testosterone 2 or 6 times baseline. RESULTS Serum testosterone increased 137 +/- 58% and 488 +/- 113%, and estradiol levels increased 27 +/- 46% and 76 +/- 57%, (P <.001 for all) during the 2 testosterone infusions. There were no differences among the placebo or testosterone groups in peak heart rate, systolic blood pressure, maximal rate pressure product, perfusion imaging scores, or the onset of ST-segment depression. CONCLUSIONS Acute testosterone infusion has neither a beneficial nor a deleterious effect on the onset and magnitude of stress-induced myocardial ischemia in men with stable CAD.
Collapse
Affiliation(s)
- Paul D Thompson
- Division of Cardiology, Hartford Hospital, Hartford, Conn 06102-5037, USA.
| | | | | | | | | | | | | | | |
Collapse
|
31
|
Wright DJ, Williams SG, Lindsay HS, Sheard KL, Thorley PJ, Sivananthan UM. Assessment of adenosine, arbutamine and dobutamine as pharmacological stress agents during (99m)Tc-tetrofosmin SPECT imaging: a randomized study. Nucl Med Commun 2001; 22:1305-11. [PMID: 11711900 DOI: 10.1097/00006231-200112000-00005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
We evaluated the use of adenosine, dobutamine and arbutamine with (99m)Tc-tetrofosmin myocardial perfusion imaging. Forty patients under investigation for suspected coronary artery disease were recruited. Each had a resting scan and two separate stress scans on different days, in a randomized cross-over study. Resultant images were blindly reported in 13 segments per scan as normal, reversible or fixed defects. A score was given (0-3) for segmental defect severity. Haemodynamic responses were as expected for each agent. Subjective side effect scores did not differ overall between agents. Adenosine caused a significantly higher incidence of abnormal taste (54%) than dobutamine and arbutamine (both 23%) and a lower incidence of palpitations (25% vs 69% and 54%, respectively), all P<0.05. Arbutamine caused significantly more chest pain than adenosine (77% vs 46%) though less flushing (35% vs 68%), both P<0.05. Comparison of the results obtained showed highly significant levels of segmental agreement for visual and semi-quantitative analysis between adenosine and arbutamine, kappa value and correlation coefficient of 0.78 and 0.86, respectively, dobutamine and adenosine 0.69 and 0.78, and arbutamine and dobutamine 0.75 and 0.78, all P<0.0001. Adenosine, arbutamine and dobutamine differ in their haemodynamic response and side effect profile but provide highly comparable results during (99m)Tc SPECT imaging.
Collapse
Affiliation(s)
- D J Wright
- The Cardiothoracic Centre, Thomas Drive, Liverpool, L14 3PE, UK.
| | | | | | | | | | | |
Collapse
|
32
|
|
33
|
Kailasnath P, Sinusas AJ. Comparison of Tl-201 with Tc-99m-labeled myocardial perfusion agents: technical, physiologic, and clinical issues. J Nucl Cardiol 2001; 8:482-98. [PMID: 11481571 DOI: 10.1067/mnc.2001.115078] [Citation(s) in RCA: 46] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Affiliation(s)
- P Kailasnath
- Department of Diagnostic Radiology, Yale University School of Medicine, New Haven, Conn, USA
| | | |
Collapse
|
34
|
Kailasnath P, Sinusas AJ. Technetium-99m-labeled myocardial perfusion agents: Are they better than thallium-201? Cardiol Rev 2001; 9:160-72. [PMID: 11304401 DOI: 10.1097/00045415-200105000-00009] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 01/08/2001] [Indexed: 11/25/2022]
Abstract
Currently, thallium-201 (201Tl)- and technetium-99m (99mTc)-labeled tracers are used interchangeably for the detection of coronary artery disease, the assessment of myocardial viability, and risk stratification. This article reviews some of the potential advantages and disadvantages of the 99mTc-labeled tracers relative to 201Tl. The basic myocardial kinetic properties and biodistribution of the commonly used 99mTc-labeled perfusion tracers are compared with those of 201Tl. The clinical value of the 99mTc-labeled perfusion tracers is then compared with that of 201Tl imaging. With regard to imaging physics and radiation safety, the 99mTc-labeled tracers are superior to 201Tl. Cost and tracer availability also may favor 99mTc-labeled perfusion tracers rather than 201Tl imaging. However, the most widely used 99mTc-labeled perfusion tracers currently approved for clinical use-99mTc-sestamibi and 99mTc-tetrofosmin-do not track myocardial flow as well as 201Tl does. This shortcoming of 99mTc-labeled perfusion tracers may reduce the sensitivity of these agents in detecting subcritical coronary artery disease. The most notable new perfusion agent is 99mTc-labeled bis(N-ethoxy, N-ethyl dithiocarbamato) nitrido technetium(v), which is considered to be the 99mTc-labeled equivalent of 201Tl. However, 99mTc-labeled bis(N-ethoxy, N-ethyl dithiocarbamato) nitrido technetium(v) is a neutral compound with kinetic properties that are very different from those of 201Tl. Myocardial perfusion imaging is often conducted in conjunction with exercise or with different pharmacologic stressors, both of which augment regional flow heterogeneity. Each of these stressors has unique effects on the coronary vasculature and influences the behavior of the radiolabeled perfusion agents. The substantial differences in myocardial uptake, clearance kinetics, and biodistribution between each of the 99mTc-labeled perfusion tracers and 201Tl should be considered in the clinical application of perfusion imaging. The myocardial retention of all of the agents is affected by myocardial viability. However, 201Tl demonstrates greater differential clearance from normal and ischemic regions (redistribution), making 201Tl a better agent for assessment of viability, particularly in patients with extremely low flow. In contrast, agents that do not redistribute, such as 99mTc-tetrofosmin, might be better for acute assessment of "risk areas" or of chest pain. Each of the available perfusion tracers has unique advantages and disadvantages that must be considered to ensure its optimal application.
Collapse
Affiliation(s)
- P Kailasnath
- Department of Diagnostic Radiology, Yale University School of Medicine, P.O. Box 208042, TE-2, New Haven, CT 06520-8042, USA
| | | |
Collapse
|
35
|
Tadamura E, Iida H, Matsumoto K, Mamede M, Kubo S, Toyoda H, Shiozaki T, Mukai T, Magata Y, Konishi J. Comparison of myocardial blood flow during dobutamine-atropine infusion with that after dipyridamole administration in normal men. J Am Coll Cardiol 2001; 37:130-6. [PMID: 11153727 DOI: 10.1016/s0735-1097(00)01043-3] [Citation(s) in RCA: 45] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
OBJECTIVES The present study was designed to compare the absolute myocardial blood flow (MBF) after intravenous dipyridamole infusion with that during dobutamine-atropine administration in normal healthy male volunteers. BACKGROUND Both safety and usefulness of dobutamine-atropine stress in myocardial perfusion imaging have been reported. However, no information exists on whether the magnitude ofhyperemia achieved with dipyridamole and dobutamine-atropine is comparable. METHODS Myocardial blood flow was measured with positron emission tomography and 15O-labeled water in 20 healthy young men (23 +/- 3 years) 1) at baseline, 2) after dipyridamole infusion (0.56 mg/kg over 4 min), and 3) during dobutamine (40 microg/kg/min) and atropine (0.25 to 1.0 mg) infusion. RESULTS The MBF was significantly increased during dipyridamole infusion and during dobutamine-atropine stress compared with at rest (4.33 +/- 1.23 and 5.89 +/- 1.58 vs. 0.67 +/- 0.16 ml/min/g, respectively, p < 0.0001). Moreover, dobutamine-atropine infusion produced greater MBF compared with dipyridamole (p = 0.0011), while coronary vascular resistance did not differ significantly after dipyridamole administration and during dobutamine-atropine infusion (17.6 +/- 7.9 vs. 18.6 +/- 5.6 mm Hg/[ml/min/g], respectively). CONCLUSIONS Near maximal coronary vasodilatation caused by dipyridamole is attainable using dobutamine and atropine in young healthy volunteers. Dobutamine in conjunction with atropine is no less effective than dipyridamole in producing myocardial hyperemia.
Collapse
Affiliation(s)
- E Tadamura
- Department of Nuclear Medicine and Diagnostic Imaging, Kyoto University Graduate School of Medicine, Japan.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
36
|
Murthy DR, White CM, Katten D, Ahlberg AW, Salloum A, Heller GV. Effect of intravenous metoprolol or intravenous metoprolol plus glucagon on dobutamine-induced myocardial ischemia. Pharmacotherapy 2000; 20:1303-9. [PMID: 11079278 DOI: 10.1592/phco.20.17.1303.34888] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
STUDY OBJECTIVE To determine the effect of metoprolol on dobutamine stress testing with technetium-99m sestamibi single-photon emission computed tomography imaging and ST-segment monitoring, and to assess the impact of intravenous glucagon on metoprolol's effects. DESIGN Randomized, double-blind, placebo-controlled trial. SETTING Community hospital. PATIENTS Twenty-two patients with known reversible perfusion defects. INTERVENTION Patients underwent dobutamine stress tests per standard protocol. Before dobutamine was begun, no therapy was given during the first visit, and patients were randomized on subsequent visits to receive metoprolol or metoprolol plus glucagon 1 mg. Metoprolol was dosed to achieve a resting predobutamine heart rate below 65 beats/minute or a total intravenous dose of 20 mg. MEASUREMENTS AND MAIN RESULTS Metoprolol reduced maximum heart rate 31%, summed stress scores 29%, and summed difference scores 43% versus control. Metoprolol plus glucagon also reduced the maximum heart rate 29% versus control. Summed stress and summed difference scores were not significantly reduced, although they were 18% and 30% lower, respectively, than control. No significant differences were found in any parameter between metoprolol and metoprolol-glucagon. CONCLUSION During dobutamine stress testing, metoprolol attenuates or eliminates evidence of myocardial ischemia. Glucagon 1 mg, although somewhat effective, does not correct this effect to the extent that it can be administered clinically.
Collapse
Affiliation(s)
- D R Murthy
- Division of Cardiology, Hartford Hospital, Connecticut, USA
| | | | | | | | | | | |
Collapse
|
37
|
Hurwitz GA, McLaughlin DS, Slomka PJ. Comparing the image quality of myocardial perfusion agents in the clinical laboratory: small test groups and large reference populations. Nucl Med Commun 2000; 21:907-15. [PMID: 11130331 DOI: 10.1097/00006231-200010000-00004] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Myocardial perfusion studies have been performed for 6 years using technetium-99m (99Tcm)-sestamibi (MIBI). In this study we evaluated a newer agent, 99Tcm-tetrofosmin (TF), on a trial basis for 2 weeks, and compared the results from each week to those in an adjacent week of MIBI use. The routine protocol included weight-based dosing, frequent dipyridamole use, and separate-day rest and stress wherever possible. During the first week, TF was used with 'usual' image timing, i.e. stress tomography performed 30-60 min after stress, and ancillary immediate images performed 4 min after injection. For the second week, 'early' tomography was performed 15-30 min after stress. TF scans (n = 53) were compared with MIBI scans for the adjacent weeks (n = 54) and with a historical reference series (n = 1800). Blinded analysis was made of tomographic image quality, peak myocardial counts and background activity (lung and abdomen) on immediate and delayed acquisitions and on tomographic reconstructions. The TF and MIBI test groups were similar with respect to gender, weight, stress protocol, tracer doses, imaging times and scintigraphic findings. Using analysis of variance, the tomographic quality scores were similar for the two observers, with stress>rest (P<0.0001), 'usual'>'early' (P<0.001) and MIBI>TF (P<0.05). Myocardial counts were approximately 20% higher with the MIBI test group than with TF at all times after stress (P=0.001), and were similar to the reference population. MIBI with usual timing gave more favourable stress abdominal background ratios than the other three agent/timing combinations. Satisfactory images could be obtained with TF, but no apparent advantage over MIBI could be attained with earlier post-stress imaging. Subtle advantages for MIBI over TF were suggested by comparison of the small test groups. In our local imaging context, these conclusions were reinforced by a large control series.
Collapse
Affiliation(s)
- G A Hurwitz
- Department of Diagnostic Radiology/Nuclear Medicine, London Health Sciences Centre, Ontario, Canada.
| | | | | |
Collapse
|