Meyer F, Garin L, Smati C, Gaspard M, Giannoli C, Rigal D. [Application of the gel test using and anti-IgA antiglobulin for the immunologic diagnosis of autoimmune hemolytic anemia with a negative direct Coombs test].
Transfus Clin Biol 1999;
6:221-6. [PMID:
10472686 DOI:
10.1016/s1246-7820(99)80032-9]
[Citation(s) in RCA: 18] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
Autoimmune hemolytic anemias (AIHA) are characterized by hyperhemolysis associated with the presence of the immunoglobulins IgG, IgM or IgA on the red cell membrane. These immunoglobulins react as auto-antibodies against the red cell auto-antigens of the patient. The diagnosis is supported by clinical and biological signs of hemolysis, and by the identification of the auto-antibodies using the direct antiglobulin test (DAT). Here we report 14 cases of patients who showed the clinical and biological profile of AIHA, but who gave a negative DAT. We therefore tried to determine the presence of IgA on the red cell membrane with a method more sensitive than the DAT: the gel test using anti-IgA. With such a gel test, we demonstrated that there were IgA auto-antibodies on the red cell membrane in the 14 cases, therefore confirming the diagnosis of AIHA. We discuss the interest of performing a gel test with anti-IgA in each case where AIHA is suspected, but in which a negative DAT has been observed.
Collapse