1
|
Weis A, Liang F, Gao J, Barnard RT, Corrie S. RNA and DNA Diagnostics on Microspheres: Current and Emerging Methods. RNA TECHNOLOGIES 2015. [DOI: 10.1007/978-3-319-17305-4_10] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|
2
|
Rödiger S, Liebsch C, Schmidt C, Lehmann W, Resch-Genger U, Schedler U, Schierack P. Nucleic acid detection based on the use of microbeads: a review. Mikrochim Acta 2014. [DOI: 10.1007/s00604-014-1243-4] [Citation(s) in RCA: 60] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
3
|
Hadd AG, Brown JT, Andruss BF, Ye F, WalkerPeach CR. Adoption of array technologies into the clinical laboratory. Expert Rev Mol Diagn 2014; 5:409-20. [PMID: 15934817 DOI: 10.1586/14737159.5.3.409] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
Array-based methods are making substantial contributions to the discovery of disease biomarkers and are fueling the growth of multianalyte testing for disease diagnosis and treatment. The distillation of high-density array results into sets of signature markers promises to improve disease staging, risk stratification and treatment decisions. To accommodate the growing requirement for multiplex testing, clinical laboratories are converting several single-analyte tests into array-based formats. However, adoption of array technologies provides several challenges to the laboratory, which must evaluate these new formats, train laboratory personnel, market the new services and obtain reimbursement for new analytes. Liquid-bead arrays are an attractive format for routine clinical diagnostics due to a combination of appropriate analyte density, simultaneous array decoding and detection, and flexibility for rapid customization. In this review, the suitability of several array platforms to diagnostic testing and applications of liquid-bead arrays for cystic fibrosis testing, multidisease carrier status assays and leukemia subtyping are discussed. As our understanding of the clinical utility of new or established biomarkers and recommendations for testing change, flexibility and adaptability of array platforms will be imperative. Future development of novel assay formats and improved quantitation will expand the number of diseases tested and lead to further integration into the diagnostic laboratory.
Collapse
Affiliation(s)
- Andrew G Hadd
- Ambion Diagnostics, 2130 Woodward Street, Austin, TX 78744, USA.
| | | | | | | | | |
Collapse
|
4
|
Zhao J, Kang L, Hu R, Gao S, Xin W, Chen W, Wang J. Rapid oligonucleotide suspension array-based multiplex detection of bacterial pathogens. Foodborne Pathog Dis 2013; 10:896-903. [PMID: 23947819 DOI: 10.1089/fpd.2012.1476] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
A gene-specific microsphere suspension array coupled with 15-plex polymerase chain reaction (PCR) was developed to screen bacterial samples rapidly for 10 strains of bacteria: Shigella spp. (S. flexneri, S. dysenteriae, and S. sonnei), Staphylococcus aureus, Vibrio cholerae (serology O1 and O139), Legionella pneumophila, and Clostridium botulinum (types A, B, and E). Fifteen sets of highly validated primers were chosen to amplify target genes simultaneously. Corresponding oligonucleotide probes directly conjugated with microsphere sets were used to specifically identify PCR amplicons. Sensitivity tests revealed that the array coupled with single PCR was able to detect purified genomic DNA at concentrations as low as 10 copies/μL, while the multiplex detection limit was 10-10⁴ copies/μL. The assay was validated using water samples artificially spiked with S. aureus and S. dysenteriae, as well as water specimens from swimming pools previously identified to contain S. aureus.
Collapse
Affiliation(s)
- Jinyin Zhao
- 1 State Key Laboratory of Pathogen and Biosecurity, Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences , Beijing, China
| | | | | | | | | | | | | |
Collapse
|
5
|
Affiliation(s)
- Shuko Harada
- University of Alabama at Birmingham Birmingham Alabama
| | - Bruce R. Korf
- University of Alabama at Birmingham Birmingham Alabama
| |
Collapse
|
6
|
Meldgaard M, Szecsi PB, Carlsen BC, Thyssen JP, Johansen JD, Menné T, Stender S. A novel multiplex analysis of filaggrin polymorphisms: a universally applicable method for genotyping. Clin Chim Acta 2012; 413:1488-92. [PMID: 22705401 DOI: 10.1016/j.cca.2012.06.014] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2012] [Revised: 05/24/2012] [Accepted: 06/07/2012] [Indexed: 11/25/2022]
Abstract
BACKGROUND The filaggrin protein is expressed as profilaggrin mainly in stratum granulosum cells of the epidermis. The profilaggrin gene codes for 10-12 filaggrin repeats. The filaggrin protein is important for skin barrier function. Filaggrin deficiency due to functional null-polymorphisms affects 8-10% of the people in Northern Europe and is a strong risk factor for several diseases. Here, we describe a novel method for efficient, multiplexed genotyping of variations in the profilaggrin gene. METHODS Five known techniques were combined: i) allele-specific PCR, ii) PCR with tagged primers, iii) asymmetric PCR, iv) multiplex PCR, and v) hybridization of single-stranded PCR products to spectrally coded microbeads carrying tag sequences as capture probes. Asymmetry of PCR was accomplished by having the tagged and allele-specific forward primers present in limiting concentrations. Asymmetry ensured that the later PCR cycles generated only single-stranded reverse-strand products. This greatly improved the assay sensitivity and allowed for simple optimization. RESULTS The specificity of the tags was verified with single PCR in wildtype and homozygous samples. Only the PCR products with the appropriate anti-tag hybridized to the corresponding beads, demonstrating the specificity of the signal. The hybridization signal is strongly dependent on single-stranded PCR products. After 46 PCR cycles, double-stranded products are clearly present, but only the single-stranded products generated in later cycles hybridize to the beads and elicit the strong signals that allow for unambiguous genotyping. CONCLUSIONS We have tested 17,000 samples for three filaggrin polymorphisms using this method, with a call rate exceeding 99% and a reagent cost of US $ 0.75 per sample. The method is universally applicable for multiplex genotyping of e.g. hereditary hemochromatosis, lactose intolerance, or cystic fibrosis.
Collapse
Affiliation(s)
- Michael Meldgaard
- Department of Clinical Biochemistry, Gentofte Hospital, University of Copenhagen, Denmark.
| | | | | | | | | | | | | |
Collapse
|
7
|
Bickmann JK, Kamin W, Wiebel M, Häuser F, Wenzel JJ, Neukirch C, Stuhrmann M, Lackner KJ, Rossmann H. A Novel Approach to CFTR Mutation Testing by Pyrosequencing-Based Assay Panels Adapted to Ethnicities. Clin Chem 2009; 55:1083-91. [DOI: 10.1373/clinchem.2008.120220] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Abstract
Background: Cystic fibrosis (CF) is a common autosomal recessive genetic disorder caused by a variety of sequence alterations in the CFTR gene [cystic fibrosis transmembrane conductance regulator (ATP-binding cassette sub-family C, member 7)]. Because the relative prevalence of mutations strongly depends on the ethnic background, first-level testing of CF as defined by recent consensus recommendations ought to be adaptable to the ethnicity of patients.
Methods: We therefore developed and implemented a diagnostic approach to first-level testing for CF based on published mutation frequencies and Pyrosequencing (PSQ) technology that we complemented with standard procedures of mutation detection at the second level.
Results: The current test system of PSQ assays for 46 target CF mutations [including CFTRdele2,3 (21 kb) and 1342-6 (T)n (5T/7T/9T)] permits recombinations of single assays to optimize sensitivities for certain ethnicities. By easy expansion of the original mutation panel, the first-level test sensitivities with other ethnic groups would be increased, provided that the mutation frequencies are known. The test was validated with our local, ethnically mixed, but mainly German population (155 patients). The mutation-detection rate for the 92 patients whose CF was confirmed by the sweat test was 89.0% for the patients of German descent (73 of the 92 patients) and 73.7% for the patients of any other origin (19 of the 92 patients). Ethnicity-adapted testing panels for our foreign CF patients would increase the sensitivities for the respective groups by approximately 5%.
Conclusions: PSQ-based genotyping is a reliable, convenient, highly flexible, and inexpensive alternative to conventional methods for first-level testing of CFTR, facilitating flexible adaptation of the analyzed mutation panel to any local ethnic group.
Collapse
Affiliation(s)
| | - Wolfgang Kamin
- CF Center of the Children’s Hospital, Johannes Gutenberg University Mainz, Mainz, Germany
| | - Matthias Wiebel
- Department of Pulmonology, Thorax Clinic of the University Clinic of Heidelberg, Heidelberg, Germany
| | | | | | | | | | - Karl J Lackner
- Department of Clinical Chemistry and Laboratory Medicine, and
| | - Heidi Rossmann
- Department of Clinical Chemistry and Laboratory Medicine, and
| |
Collapse
|
8
|
Pratt VM, Caggana M, Bridges C, Buller AM, DiAntonio L, Highsmith WE, Holtegaard LM, Muralidharan K, Rohlfs EM, Tarleton J, Toji L, Barker SD, Kalman LV. Development of genomic reference materials for cystic fibrosis genetic testing. J Mol Diagn 2009; 11:186-93. [PMID: 19359498 PMCID: PMC2671335 DOI: 10.2353/jmoldx.2009.080149] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/29/2008] [Indexed: 11/20/2022] Open
Abstract
The number of different laboratories that perform genetic testing for cystic fibrosis is increasing. However, there are a limited number of quality control and other reference materials available, none of which cover all of the alleles included in commercially available reagents or platforms. The alleles in many publicly available cell lines that could serve as reference materials have neither been confirmed nor characterized. The Centers for Disease Control and Prevention-based Genetic Testing Reference Material Coordination Program, in collaboration with members of the genetic testing community as well as Coriell Cell Repositories, have characterized an extended panel of publicly available genomic DNA samples that could serve as reference materials for cystic fibrosis testing. Six cell lines [containing the following mutations: E60X (c.178G>T), 444delA (c.312delA), G178R (c.532G>C), 1812-1G>A (c.1680-1G>A), P574H (c.1721C>A), Y1092X (c.3277C>A), and M1101K (c.3302T>A)] were selected from those existing at Coriell, and seven [containing the following mutations: R75X (c.223C>T), R347H (c.1040G>A), 3876delA (c.3744delA), S549R (c.1646A>C), S549N (c.1647G>A), 3905insT (c.3773_3774insT), and I507V (c.1519A>G)] were created. The alleles in these materials were confirmed by testing in six different volunteer laboratories. These genomic DNA reference materials will be useful for quality assurance, proficiency testing, test development, and research and should help to assure the accuracy of cystic fibrosis genetic testing in the future. The reference materials described in this study are all currently available from Coriell Cell Repositories.
Collapse
|
9
|
Lee J, Kim O, Jung J, Na K, Heo P, Hyun J. Simple fabrication of a smart microarray of polystyrene microbeads for immunoassay. Colloids Surf B Biointerfaces 2009; 72:173-80. [PMID: 19410434 DOI: 10.1016/j.colsurfb.2009.03.031] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2009] [Revised: 03/24/2009] [Accepted: 03/30/2009] [Indexed: 11/25/2022]
Abstract
We describe a simple method to fabricate an array of polystyrene microbeads (PS microbeads) conjugated with an elastin-like polypeptide (ELP) on a glass surface using a removable polymer template (RPT). A thin layer of adhesive was spun-cast on glass and cured by UV radiation. Micropatterns of an RPT were then transferred onto the surface by microcontact printing. The adhesion of PS microbeads on the surface depended on the adhesion performance of the adhesive layer, which could be adjusted by irradiation time. An array of PS microbeads conjugated with ELP was used for a smart immunoassay of prostate-specific antigen (PSA), a cancer marker. By controlling the phase transition of ELP molecules, PSA molecules were selectively adhered or released from the bead surface. The selective and reversible binding of PSA molecules on the bead surface was characterized with fluorescence microscopy.
Collapse
Affiliation(s)
- Jonghwan Lee
- Department of Biosystems and Biomaterials Science and Engineering, Seoul National University, Seoul 151-742, Republic of Korea
| | | | | | | | | | | |
Collapse
|
10
|
Newkirk HL, Rogan PK, Miralles M, Knoll JHM. Determination of genomic copy number with quantitative microsphere hybridization. Hum Mutat 2006; 27:376-86. [PMID: 16541397 DOI: 10.1002/humu.20312] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
We developed a novel quantitative microsphere suspension hybridization (QMH) assay for determination of genomic copy number by flow cytometry. Single copy (sc) products ranging in length from 62 to 2,304 nucleotides [Rogan et al., 2001; Knoll and Rogan, 2004] from ABL1 (chromosome 9q34), TEKT3 (17p12), PMP22 (17p12), and HOXB1 (17q21) were conjugated to spectrally distinct polystyrene microspheres. These conjugated probes were used in multiplex hybridization to detect homologous target sequences in biotinylated genomic DNA extracted from fixed cell pellets obtained for cytogenetic studies. Hybridized targets were bound to phycoerythrin-labeled streptavidin; then the spectral emissions of both target and conjugated microsphere were codetected by flow cytometry. Prior amplification of locus-specific target DNA was not required because sc probes provide adequate specificity and sensitivity for accurate copy number determination. Copy number differences were distinguishable by comparing the mean fluorescence intensities (MFI) of test probes with a biallelic reference probe in genomic DNA of patient samples and abnormal cell lines. Concerted 5' ABL1 deletions in patient samples with a chromosome 9;22 translocation and chronic myelogenous leukemia were confirmed by comparison of the mean fluorescence intensities of ABL1 test probes with a HOXB1 reference probe. The relative intensities of the ABL1 probes were reduced to 0.59+/-0.02 fold in three different deletion patients and increased 1.42+/-0.01 fold in three trisomic 9 cell lines. TEKT3 and PMP22 probes detected proportionate copy number increases in five patients with Charcot-Marie-Tooth Type 1a disease and chromosome 17p12 duplications. Thus, the assay is capable of distinguishing one allele and three alleles from a biallelic reference sequence, regardless of chromosomal context.
Collapse
Affiliation(s)
- Heather L Newkirk
- Laboratory of Genomic Disorders, Children's Mercy Hospitals and Clinics, University of Missouri-Kansas City, Kansas City, Missouri 64108, USA
| | | | | | | |
Collapse
|
11
|
Brown JT, Lahey C, Laosinchai-Wolf W, Hadd AG. Polymorphisms in the glucocerebrosidase gene and pseudogene urge caution in clinical analysis of Gaucher disease allele c.1448T>C (L444P). BMC MEDICAL GENETICS 2006; 7:69. [PMID: 16887033 PMCID: PMC1559599 DOI: 10.1186/1471-2350-7-69] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 03/17/2006] [Accepted: 08/03/2006] [Indexed: 11/24/2022]
Abstract
Background Gaucher disease is a potentially severe lysosomal storage disorder caused by mutations in the human glucocerebrosidase gene (GBA). We have developed a multiplexed genetic assay for eight diseases prevalent in the Ashkenazi population: Tay-Sachs, Gaucher type I, Niemann-Pick types A and B, mucolipidosis type IV, familial dysautonomia, Canavan, Bloom syndrome, and Fanconi anemia type C. This assay includes an allelic determination for GBA allele c.1448T>C (L444P). The goal of this study was to clinically evaluate this assay. Methods Biotinylated, multiplex PCR products were directly hybridized to capture probes immobilized on fluorescently addressed microspheres. After incubation with streptavidin-conjugated fluorophore, the reactions were analyzed by Luminex IS100. Clinical evaluations were conducted using de-identified patient DNA samples. Results We evaluated a multiplexed suspension array assay that includes wild-type and mutant genetic determinations for Gaucher disease allele c.1448T>C. Two percent of samples reported to be wild-type by conventional methods were observed to be c.1448T>C heterozygous using our assay. Sequence analysis suggested that this phenomenon was due to co-amplification of the functional gene and a paralogous pseudogene (ΨGBA) due to a polymorphism in the primer-binding site of the latter. Primers for the amplification of this allele were then repositioned to span an upstream deletion in the pseudogene, yielding a much longer amplicon. Although it is widely reported that long amplicons negatively impact amplification or detection efficiency in recently adopted multiplex techniques, this assay design functioned properly and resolved the occurrence of false heterozygosity. Conclusion Although previously available sequence information suggested GBA gene/pseudogene discrimination capabilities with a short amplified product, we identified common single-nucleotide polymorphisms in the pseudogene that required amplification of a larger region for effective discrimination.
Collapse
|
12
|
Korf BR. Overview of molecular genetic diagnosis. CURRENT PROTOCOLS IN HUMAN GENETICS 2006; Chapter 9:Unit 9.1. [PMID: 18428397 DOI: 10.1002/0471142905.hg0901s48] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
This unit describes the two approaches for molecular genetic diagnosis, direct mutation analysis and linkage studies. Direct mutation analysis is possible if the gene responsible for a disorder has been cloned and techniques exist to detect mutations. Genetic linkage analysis is used when polymorphic markers are available that are closely linked to a disease gene but the gene itself has not been cloned, or when it is difficult or impossible to detect mutations in the gene. For direct mutation analysis, the unit offers a review of the types of mutations that can be detected and the strategies that can be employed for their detection. The unit then describes the types of disorders that are best suited for linkage-based analysis and offers guidance for interpreting the data.
Collapse
Affiliation(s)
- Bruce R Korf
- University of Alabama at Birmingham, Birmingham, Alabama, USA
| |
Collapse
|
13
|
Kuller L, Watanabe R, Anderson D, Grant R. Development of a whole-virus multiplex flow cytometric assay for antibody screening of a specific pathogen-free primate colony. Diagn Microbiol Infect Dis 2005; 53:185-93. [PMID: 16243475 DOI: 10.1016/j.diagmicrobio.2005.05.012] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2005] [Accepted: 05/12/2005] [Indexed: 11/25/2022]
Abstract
Our goal was to determine if a multiplex technique using a fluorescent bead-based flow cytometric assay could yield results comparable to traditional enzyme-linked immunosorbent assay (ELISA) in terms of sensitivity, specificity, cross-reactivity, and throughput. We applied both techniques to serologic screening of specific pathogen-free macaques, for type D simian retrovirus, simian T-lymphotropic virus, Cercopithicine herpesvirus 1, and simian immunodeficiency virus, and found a high correlation between the bead-based multiplex assay and ELISA. The multiplex assay demonstrated greater sensitivity with no loss in specificity when compared to the ELISA. A lower false-positive rate with the multiplex assay decreased the number of confirmatory Western blots required. Using the multiplex assay, we were able to screen samples for 4 viruses simultaneously in the time it took to perform a single-virus ELISA, resulting in a faster turnaround time and higher throughput. The multiplexed assay provided greater sensitivity, increased stability, and better performance than ELISA.
Collapse
Affiliation(s)
- LaRene Kuller
- Washington National Primate Research Center, University of Washington, Box 357331, Seattle, 98195, USA
| | | | | | | |
Collapse
|
14
|
Dunbar SA. Applications of Luminex xMAP technology for rapid, high-throughput multiplexed nucleic acid detection. Clin Chim Acta 2005; 363:71-82. [PMID: 16102740 PMCID: PMC7124242 DOI: 10.1016/j.cccn.2005.06.023] [Citation(s) in RCA: 409] [Impact Index Per Article: 21.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2005] [Accepted: 06/06/2005] [Indexed: 02/07/2023]
Abstract
Background As we enter the post-genome sequencing era and begin to sift through the enormous amount of genetic information now available, the need for technologies that allow rapid, cost-effective, high-throughput detection of specific nucleic acid sequences becomes apparent. Multiplexing technologies, which allow for simultaneous detection of multiple nucleic acid sequences in a single reaction, can greatly reduce the time, cost and labor associated with single reaction detection technologies. Methods The Luminex® xMAP™ system is a multiplexed microsphere-based suspension array platform capable of analyzing and reporting up to 100 different reactions in a single reaction vessel. This technology provides a new platform for high-throughput nucleic acid detection and is being utilized with increasing frequency. Here we review specific applications of xMAP technology for nucleic acid detection in the areas of single nucleotide polymorphism (SNP) genotyping, genetic disease screening, gene expression profiling, HLA DNA typing and microbial detection. Conclusions These studies demonstrate the speed, efficiency and utility of xMAP technology for simultaneous, rapid, sensitive and specific nucleic acid detection, and its capability to meet the current and future requirements of the molecular laboratory for high-throughput nucleic acid detection.
Collapse
|
15
|
|