1
|
Cox S, Bergman J, Hawkins S, Sladky K. Development of a method for the determination of hydromorphone in plasma by LC-MS. Biomed Chromatogr 2018; 32:e4357. [DOI: 10.1002/bmc.4357] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2018] [Revised: 07/20/2018] [Accepted: 07/24/2018] [Indexed: 11/08/2022]
Affiliation(s)
- Sherry Cox
- Department of Biomedical and Diagnostic Sciences; The University of Tennessee, College of Veterinary Medicine; Knoxville TN USA
| | - Joan Bergman
- Department of Biomedical and Diagnostic Sciences; The University of Tennessee, College of Veterinary Medicine; Knoxville TN USA
| | - Shawna Hawkins
- Department of Surgical Sciences, School of Veterinary Medicine; The University of Wisconsin; Madison Wisconsin USA
| | - Kurt Sladky
- Department of Surgical Sciences, School of Veterinary Medicine; The University of Wisconsin; Madison Wisconsin USA
| |
Collapse
|
2
|
Moeller KE, Kissack JC, Atayee RS, Lee KC. Clinical Interpretation of Urine Drug Tests: What Clinicians Need to Know About Urine Drug Screens. Mayo Clin Proc 2017; 92:774-796. [PMID: 28325505 DOI: 10.1016/j.mayocp.2016.12.007] [Citation(s) in RCA: 97] [Impact Index Per Article: 13.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2016] [Revised: 11/21/2016] [Accepted: 12/12/2016] [Indexed: 10/19/2022]
Abstract
Urine drug testing is frequently used in clinical, employment, educational, and legal settings and misinterpretation of test results can result in significant adverse consequences for the individual who is being tested. Advances in drug testing technology combined with a rise in the number of novel misused substances present challenges to clinicians to appropriately interpret urine drug test results. Authors searched PubMed and Google Scholar to identify published literature written in English between 1946 and 2016, using urine drug test, screen, false-positive, false-negative, abuse, and individual drugs of abuse as key words. Cited references were also used to identify the relevant literature. In this report, we review technical information related to detection methods of urine drug tests that are commonly used and provide an overview of false-positive/false-negative data for commonly misused substances in the following categories: cannabinoids, central nervous system (CNS) depressants, CNS stimulants, hallucinogens, designer drugs, and herbal drugs of abuse. We also present brief discussions of alcohol and tricyclic antidepressants as related to urine drug tests, for completeness. The goal of this review was to provide a useful tool for clinicians when interpreting urine drug test results and making appropriate clinical decisions on the basis of the information presented.
Collapse
Affiliation(s)
| | | | - Rabia S Atayee
- UCSD Skaggs School of Pharmacy and Pharmaceutical Sciences, La Jolla, CA
| | - Kelly C Lee
- UCSD Skaggs School of Pharmacy and Pharmaceutical Sciences, La Jolla, CA
| |
Collapse
|
3
|
Valtier S, Mueck RL, Bebarta VS. Quantitative method for analysis of hydrocodone, hydromorphone and norhydrocodone in human plasma by liquid chromatography–tandem mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2013; 925:40-5. [PMID: 23523877 DOI: 10.1016/j.jchromb.2013.02.030] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2012] [Revised: 02/14/2013] [Accepted: 02/25/2013] [Indexed: 11/18/2022]
Affiliation(s)
- Sandra Valtier
- Clinical Research Division, 59th Medical Wing, Lackland AFB, TX 78236-5319, USA.
| | | | | |
Collapse
|
4
|
Valtier S, Bebarta VS. Excretion Profile of Hydrocodone, Hydromorphone and Norhydrocodone in Urine Following Single Dose Administration of Hydrocodone to Healthy Volunteers. J Anal Toxicol 2012; 36:507-14. [DOI: 10.1093/jat/bks058] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
5
|
Sun L, Pan Y, Ding L, Luo X, Yan Z, Liu C, Qian Y, Chu Y. Determination of hydromorphone in human plasma by a sensitive RP-HPLC–ESI-MS method and its application to a clinical pharmacokinetic study in postoperative patients after low dose intravenous administration with infusion pump. J Pharm Biomed Anal 2012; 61:15-21. [DOI: 10.1016/j.jpba.2011.11.012] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2011] [Revised: 11/09/2011] [Accepted: 11/10/2011] [Indexed: 10/15/2022]
|
6
|
Hao GT, Chen Y, Dong RH, Qu HY, Liang YG, Li YY, Zheng ZJ, Gao HZ, Liu ZY. Simultaneous Determination of Hydrocodone, and Its Two Metabolites in Human Plasma by HPLC–MS–MS. Chromatographia 2011. [DOI: 10.1007/s10337-011-2118-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
7
|
Zhang R, Wang B, Wei C, Yuan G, Guo R. Determination and Pharmacokinetic Study of Hydrocodone in Human Plasma by Liquid Chromatography Coupled with Tandem Mass Spectrometry. ACTA ACUST UNITED AC 2009; 37:203-7. [DOI: 10.1080/10731190903198574] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
8
|
Kline KG, Finney GL, Wu CC. Quantitative strategies to fuel the merger of discovery and hypothesis-driven shotgun proteomics. BRIEFINGS IN FUNCTIONAL GENOMICS AND PROTEOMICS 2009; 8:114-25. [PMID: 19398505 DOI: 10.1093/bfgp/elp008] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The ultimate goal of most shotgun proteomic pipelines is the discovery of novel biomarkers to direct the development of quantitative diagnostics for the detection and treatment of disease. Differential comparisons of biological samples identify candidate peptides that can serve as proxys of candidate proteins. While these discovery approaches are robust and fairly comprehensive, they have relatively low throughput. When merged with targeted mass spectrometry, this pipeline can fuel hypothesis-driven studies and the development of novel diagnostics and therapeutics.
Collapse
|
9
|
Bioanalytical hydrophilic interaction chromatography: recent challenges, solutions and applications. Bioanalysis 2009; 1:239-53. [DOI: 10.4155/bio.09.12] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
Hydrophilic interaction chromatography (HILIC) has, in recent years, been shown to be an important supplement to reversed-phase liquid chromatography for polar analytes. HILIC, in conjunction with tandem mass spectrometry (MS/MS), has been steadily gaining acceptance in the analysis of polar compounds from complex biological matrices. This hyphenated technique offers the advantages of improved sensitivity by employing high organic content in the mobile phase, shortened sample preparation time with direct injection of the organic-solvent extracts of biological samples and the potential for ultra-fast analysis because of low-column backpressure. This article reviews recent challenges presented by HILIC, advancements in the better understanding of retention characteristics of analytes with different mobile- and stationary-phase compositions and solutions to ion suppression and interference problems encountered in HILIC–MS/MS assays. Applications of HILIC–MS/MS are summarized, including those for pharmacokinetic studies, metabolic studies, therapeutic drug monitoring and clinical diagnostics.
Collapse
|
10
|
Hsieh Y. Potential of HILIC-MS in quantitative bioanalysis of drugs and drug metabolites. J Sep Sci 2008; 31:1481-91. [DOI: 10.1002/jssc.200700451] [Citation(s) in RCA: 102] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
11
|
Ismaiel OA, Halquist MS, Elmamly MY, Shalaby A, Karnes HT. Monitoring phospholipids for assessment of matrix effects in a liquid chromatography-tandem mass spectrometry method for hydrocodone and pseudoephedrine in human plasma. J Chromatogr B Analyt Technol Biomed Life Sci 2007; 859:84-93. [PMID: 17936695 DOI: 10.1016/j.jchromb.2007.09.007] [Citation(s) in RCA: 67] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2007] [Revised: 09/05/2007] [Accepted: 09/06/2007] [Indexed: 10/22/2022]
Abstract
Matrix effects resulting in ion suppression or enhancement have been shown to be a source of variability and inaccuracy in bioanalytical mass spectrometry. Glycerophosphocholines may cause significant matrix ionization effects during quantitative LC/MS/MS analysis and are known to fragment to form characteristic ions (m/z 184) in electrospray mass spectrometry. This ion was used to monitor ion suppression effects in the determination of hydrocodone and pseudoephedrine in human plasma as a means to track and avoid these effects. The m/z 184 ion fragment was detected in both plasma extracts and solutions of phosphatidylcholine. Post-column infusion studies showed that the ion suppression for both drugs and internal standards correlated with the elution of phospholipids. HPLC conditions were adjusted to chromatographically resolve the peaks of interest from the phospholipids. Upon repeated injection, the elution time of the phospholipids decreased while elution of the analyte peaks remained unchanged. This resulted in co-elution and significantly affected peak shape and internal standard response for the analytes. It was decided to use the phospholipid fragment to monitor this matrix effect in validation samples. The resulting method demonstrated intra-day and inter-day precision within 4.5 and 5.6% for hydrocodone and pseudoephedrine, respectively, and accuracy within 8.9 and 8.7% for hydrocodone, and pseudoephedrine, respectively. There was no statistically significant difference in the internal standard response for the determination with and without monitoring the phospholipid fragment ion. We found that monitoring the phospholipid fragment was useful in method development to avoid the matrix effects, and in routine analysis to provide a practical way to ensure the avoidance of matrix effects in each individual sample.
Collapse
Affiliation(s)
- Omnia A Ismaiel
- Virginia Commonwealth University, School of Pharmacy, Department of Pharmaceutics, PO Box 980533, 410 N 12th Street, Richmond, VA 23298-0533, United States.
| | | | | | | | | |
Collapse
|
12
|
Deventer K, Pozo OJ, Van Eenoo P, Delbeke FT. Development of a qualitative liquid chromatography/tandem mass spectrometric method for the detection of narcotics in urine relevant to doping analysis. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2007; 21:3015-23. [PMID: 17708509 DOI: 10.1002/rcm.3142] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
A new screening procedure for 18 narcotics in urine for anti-doping purposes has been developed using liquid chromatography/triple quadrupole mass spectrometry (LC/MS). Electrospray ionization (ESI) was used as interface. Infusion experiments were performed for all substances to investigate their mass spectrometric behaviour in terms of selecting product specific ions. These product ions were then used to develop a tandem mass spectrometric method using selected reaction monitoring (SRM). For the LC/MS analysis, chromatography was performed on an octadecylsilane column. The total run time of the chromatographic method was 5.5 min. For the sample preparation prior to LC/MS analysis, the urine samples were liquid-liquid extracted at pH 9.5 after overnight enzymatic hydrolysis. Two extraction solvents were evaluated: dichloromethane/methanol 9/1 (v/v), which is currently used for the extraction of narcotics, and diethyl ether, used for the extraction of steroids. With diethyl ether the detection limits for all compounds ranged between 0.5 and 20 ng/mL and with the mixture containing dichloromethane the detection limits ranged between 0.5 and 10 ng/mL. Taking into account the minimum required performance limits of the World Anti-Doping Agency of 200 ng/mL for narcotics, diethyl ether can also be considered as extraction solvent for narcotics. Finally, the described method was applied to the analysis of urine samples previously found to contain narcotics by our routine gas chromatography/mass spectrometry (GC/MS) method.
Collapse
Affiliation(s)
- Koen Deventer
- Ghent University (UGent), Department of Clinical Chemistry, Microbiology and Immunology, Doping Control Laboratory (DoCoLab), Technologiepark 30, B-9052 Zwijnaarde, Belgium.
| | | | | | | |
Collapse
|
13
|
Musshoff F, Trafkowski J, Kuepper U, Madea B. An automated and fully validated LC-MS/MS procedure for the simultaneous determination of 11 opioids used in palliative care, with 5 of their metabolites. JOURNAL OF MASS SPECTROMETRY : JMS 2006; 41:633-40. [PMID: 16541404 DOI: 10.1002/jms.1021] [Citation(s) in RCA: 83] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
A fully validated liquid chromatographic procedure coupled with electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) is presented for quantitative determination of the opioids buprenorphine, codeine, fentanyl, hydromorphone, methadone, morphine, oxycodone, oxymorphone, piritramide, tilidine, and tramadol together with their metabolites bisnortilidine, morphine-glucuronides, norfentanyl, and nortilidine in blood plasma after an automatically performed solid-phase extraction (SPE). Separation was achieved in 35 min on a Phenomenex C12 MAX-RP column (4 microm, 150 x 2 mm) using a gradient of ammonium formiate buffer (pH 3.5) and acetonitrile. The validation data were within the required limits. The assay was successfully applied to authentic plasma samples, allowing confirmation of the diagnosis of overdose situations as well as monitoring of patients' compliance, especially in patients under palliative care.
Collapse
Affiliation(s)
- F Musshoff
- Institute of Forensic Medicine, Stiftsplatz 12, 53111 Bonn, Germany.
| | | | | | | |
Collapse
|
14
|
Li W, Li Y, Francisco DT, Naidong W. Hydrophilic interaction liquid chromatographic tandem mass spectrometric determination of atenolol in human plasma. Biomed Chromatogr 2005; 19:385-93. [PMID: 15651086 DOI: 10.1002/bmc.462] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
A hydrophilic interaction liquid chromatographic method with tandem mass spectrometry for the determination of atenolol, a beta-blocking agent, in human plasma has been developed and validated over the curve range of 10--2000 ng/mL. The assay was based on protein precipitation followed by evaporation of the extraction solvent, reconstitution with acetonitrile, and chromatography on an Hypersil silica column (50 x 4.6 mm) using a low aqueous--high organic mobile phase. The mobile phase consists of 85% acetonitrile, 15% water, 0.5% acetic acid and 0.04% trifluoroacetic acid and runs isocratically at a flow rate of 2.0 mL/min. The column ef fluent was split so that 50% of it was transferred into the LC-MS/MS interface operated in positive electrospray ionization mode. The chromatographic run time was 2.0 min per injection. Atenolol and the internal standard, atenolol-d(7), showed a retention time of 1.0 min. The inter-day and intra-day precision and accuracy of the quality control samples were <5.3% relative standard deviation and <8.0% relative error, respectively. To explore the application of the current method for the analysis of other beta-blocking agents, propranolol and metoprolol were tested under the same chromatographic conditions with retention times of 0.68 and 0.75 min, respectively. The present method could be used for therapeutic drug monitoring, pharmacokinetic and drug--drug interaction studies of beta-blocking agents.
Collapse
Affiliation(s)
- Wenkui Li
- Covance Laboratories Inc., Madison, WI 53704, USA
| | | | | | | |
Collapse
|
15
|
Naidong W. Bioanalytical liquid chromatography tandem mass spectrometry methods on underivatized silica columns with aqueous/organic mobile phases. J Chromatogr B Analyt Technol Biomed Life Sci 2004; 796:209-24. [PMID: 14581062 DOI: 10.1016/j.jchromb.2003.08.026] [Citation(s) in RCA: 190] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
This review article summarizes the recent progress on bioanalytical LC-MS/MS methods using underivatized silica columns and aqueous/organic mobile phases. Various types of polar analytes were extracted by using protein precipitation (PP), liquid/liquid extraction (LLE) or solid-phase extraction (SPE) and were then analyzed using LC-MS/MS on the silica columns. Use of silica columns and aqueous/organic mobile phases could significantly enhance LC-MS/MS method sensitivity, due to the high organic content in the mobile phase. Thanks to the very low backpressure generated from the silica column with low aqueous/high organic mobile phases, LC-MS/MS methods at high flow rates are feasible, resulting in significant timesaving. Because organic solvents have weaker eluting strength than water, direct injection of the organic solvent extracts from the reversed-phase solid-phase extraction onto the silica column was possible. Gradient elution on the silica columns using aqueous/organic mobile phases was also demonstrated. Contrary to what is commonly perceived, the silica column demonstrated superior column stability. This technology can be a valuable supplement to the reversed-phase LC-MS/MS.
Collapse
Affiliation(s)
- Weng Naidong
- Covance Laboratories Inc., 3301 Kinsman Boulevard, Madison, WI 53704, USA.
| |
Collapse
|
16
|
Vanderford BJ, Pearson RA, Rexing DJ, Snyder SA. Analysis of Endocrine Disruptors, Pharmaceuticals, and Personal Care Products in Water Using Liquid Chromatography/Tandem Mass Spectrometry. Anal Chem 2003; 75:6265-74. [PMID: 14616010 DOI: 10.1021/ac034210g] [Citation(s) in RCA: 298] [Impact Index Per Article: 14.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A method has been developed for the trace analysis of 27 compounds from a diverse group of pharmaceuticals, steroids, pesticides, and personal care products. The method employs solid-phase extraction (SPE) and liquid chromatography/tandem mass spectrometry (LC/MS/MS), using electrospray ionization (ESI) in both positive and negative modes and atmospheric pressure chemical ionization in positive mode. Unlike many previous methods, a single SPE procedure using 1 L of water coupled to a simple LC method is used for all ionization modes. Instrument detection limits for most compounds were below 1.0 pg on column with reporting limits of 1.0 ng/L in water. Recoveries for most compounds in deionized water were greater than 80%. Sulfuric acid was found to be the preferred sample preservative, and structures of all MS/MS product ions are proposed. Matrix effects from waters with a high content of treated municipal effluent were observed in both ESI modes and are discussed in the paper.
Collapse
Affiliation(s)
- Brett J Vanderford
- Southern Nevada Water Authority, 243 Lakeshore Road, Boulder City, Nevada 89005, USA.
| | | | | | | |
Collapse
|
17
|
Eerkes A, Shou WZ, Naidong W. Liquid/liquid extraction using 96-well plate format in conjunction with hydrophilic interaction liquid chromatography-tandem mass spectrometry method for the analysis of fluconazole in human plasma. J Pharm Biomed Anal 2003; 31:917-28. [PMID: 12684104 DOI: 10.1016/s0731-7085(02)00672-6] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
A bioanalytical method using automated sample transferring, automated liquid/liquid extraction (LLE) and hydrophilic interaction liquid chromatography-tandem mass spectrometry was developed for the determination of fluconazole in human plasma. Samples of 0.05 ml were transferred into 96-well plate using automatic liquid handler (Multiprobe II). Automated LLE was carried out on a 96-channel programmable liquid handling workstation (Quadra 96) using methyl-tetra butyl ether as the extraction solvent. The extract was evaporated to dryness, reconstituted, and injected onto a silica column using an aqueous-organic mobile phase. The chromatographic run time was 2.0 min per injection, with retention times of 1.47 and 1.44 min for fluconazole and internal standard (IS) ritonavir, respectively. The detection was by monitoring fluconazole at m/z 307-->238 and IS at m/z 721-->296, respectively. The standard curve range was 0.5-100 ng ml(-1). The inter-day precision and accuracy of the quality control samples were <7.1% relative standard deviation and <2.2% relative error.
Collapse
Affiliation(s)
- Angela Eerkes
- Covance Laboratories Inc, Department of Bioanalytical Chemistry, 3301 Kinsman Boulevard, Madison, WI 53704, USA
| | | | | |
Collapse
|
18
|
Chapter 5 Automation tools and strategies for bioanalysis. ACTA ACUST UNITED AC 2003. [DOI: 10.1016/s1464-3456(03)80007-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|
19
|
Current literature in mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2002; 37:765-776. [PMID: 12125010 DOI: 10.1002/jms.254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
|
20
|
Shou WZ, Chen YL, Eerkes A, Tang YQ, Magis L, Jiang X, Naidong W. Ultrafast liquid chromatography/tandem mass spectrometry bioanalysis of polar analytes using packed silica columns. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2002; 16:1613-1621. [PMID: 12203228 DOI: 10.1002/rcm.762] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Ultrafast liquid chromatography/tandem mass spectrometry (LC/MS/MS) bioanalysis was demonstrated with the use of packed silica columns operated under elevated flow rates. A special effort has been made to achieve ultrafast analysis without sacrificing chromatographic resolution. Two multiple analyte/metabolites assays, (1) morphine/morphine-6-glucuronide(M6G)/morphine-3-glucuronide(M3G) and (2) midazolam/1'-hydroxymidazolam/4-hydroxymidazolam, were used to demonstrate the speed, sensitivity, peak shape and separation of the ultrafast methods utilizing silica columns. In both methods adequate chromatographic separation was a necessity because quantitation results would be otherwise compromised due to cross interference between different selected reaction monitoring (SRM) transitions. Baseline resolutions between morphine, M6G and M3G in human plasma extracts were achieved within 30 s on a 50 x 3 mm Betasil silica column operated at 4 mL/min of isocratic acetonitrile/water mobile phase. The total injection-to-injection cycle time was 48 s with a simple, single-autosampler/single-column setup, when a Shimadzu SIL-HT autosampler was used. Baseline resolution between 1'-hydroxymidazolam and 4-hydroxymidalolam in monkey plasma extracts was achieved within 33 s using similar conditions. Due to the absence of carry-over in this case, no rinsing of the injection needle was necessary, resulting in a cycle time of only 39 s/sample. These ultrafast methods were successfully used to analyze extracted biological samples and proved to be reproducible, reliable and generated equivalent pharmaco-kinetic (PK) results to those obtained by regular flow LC/MS/MS analysis to support discovery PK studies.
Collapse
Affiliation(s)
- Wilson Z Shou
- Covance Laboratories Inc., 3301 Kinsman Boulevard, Madison, WI 53704, USA.
| | | | | | | | | | | | | |
Collapse
|
21
|
Naidong W, Shou WZ, Addison T, Maleki S, Jiang X. Liquid chromatography/tandem mass spectrometric bioanalysis using normal-phase columns with aqueous/organic mobile phases - a novel approach of eliminating evaporation and reconstitution steps in 96-well SPE. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2002; 16:1965-1975. [PMID: 12362389 DOI: 10.1002/rcm.817] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Bioanalytical methods using automated 96-well solid-phase extraction (SPE) and liquid chromatography with electrospray tandem mass spectrometry (LC/MS/MS) are widely used in the pharmaceutical industry. SPE methods typically require manual steps of drying of the eluates and reconstituting of the analytes with a suitable injection solvent possessing elution strength weaker than the mobile phase. In this study, we demonstrated a novel approach of eliminating these two steps in 96-well SPE by using normal-phase LC/MS/MS methods with low aqueous/high organic mobile phases, which consisted of 70-95% organic solvent, 5-30% water, and small amount of volatile acid or buffer. While the commonly used SPE elution solvents (i.e. acetonitrile and methanol) have stronger elution strength than a mobile phase on reversed-phase chromatography, they are weaker elution solvents than a mobile phase for normal-phase LC/MS/MS and therefore can be injected directly. Analytical methods for a range of polar pharmaceutical compounds, namely, omeprazole, metoprolol, fexofenadine, pseudoephedrine as well as rifampin and its metabolite 25-desacetyl-rifampin, in biological fluids, were developed and optimized based on the foregoing principles. As a result of the time saving, a batch of 96 samples could be processed in one hour. These bioanalytical LC/MS/MS methods were validated according to "Guidance for Industry - Bioanalytical Method Validation" recommended by the Food and Drug Administration (FDA) of the United States.
Collapse
Affiliation(s)
- Weng Naidong
- Bioanalytical Chemistry Department, Covance Laboratories, Inc., 3301 Kinsman Boulevard, Madison, WI 53704, USA.
| | | | | | | | | |
Collapse
|