1
|
Martis R, Emilia O, Nurdiati DS, Brown J. Intermittent auscultation (IA) of fetal heart rate in labour for fetal well-being. Cochrane Database Syst Rev 2017; 2:CD008680. [PMID: 28191626 PMCID: PMC6464556 DOI: 10.1002/14651858.cd008680.pub2] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
BACKGROUND The goal of fetal monitoring in labour is the early detection of a hypoxic baby. There are a variety of tools and methods available for intermittent auscultation (IA) of the fetal heart rate (FHR). Low- and middle-income countries usually have only access to a Pinard/Laënnec or the use of a hand-held Doppler device. Currently, there is no robust evidence to guide clinical practice on the most effective IA tool to use, timing intervals and length of listening to the fetal heart for women during established labour. OBJECTIVES To evaluate the effectiveness of different tools for IA of the fetal heart rate during labour including frequency and duration of auscultation. SEARCH METHODS We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (19 September 2016), contacted experts and searched reference lists of retrieved articles. SELECTION CRITERIA All published and unpublished randomised controlled trials (RCTs) or cluster-RCTs comparing different tools and methods used for intermittent fetal auscultation during labour for fetal and maternal well-being. Quasi-RCTs, and cross-over designs were not eligible for inclusion. DATA COLLECTION AND ANALYSIS All review authors independently assessed eligibility, extracted data and assessed risk of bias for each trial. Data were checked for accuracy. MAIN RESULTS We included three studies (6241 women and 6241 babies), but only two studies are included in the meta-analyses (3242 women and 3242 babies). Both were judged as high risk for performance bias due to the inability to blind the participants and healthcare providers to the interventions. Evidence was graded as moderate to very low quality; the main reasons for downgrading were study design limitations and imprecision of effect estimates. Intermittent Electronic Fetal Monitoring (EFM) using Cardiotocography (CTG) with routine Pinard (one trial)There was no clear difference between groups in low Apgar scores at five minutes (reported as < six at five minutes after birth) (risk ratio (RR) 0.66, 95% confidence interval (CI) 0.24 to 1.83, 633 babies, very low-quality evidence). There were no clear differences for perinatal mortality (RR 0.88, 95% CI 0.34 to 2.25; 633 infants, very low-quality evidence). Neonatal seizures were reduced in the EFM group (RR 0.05, 95% CI 0.00 to 0.89; 633 infants, very low-quality evidence). Other important infant outcomes were not reported: mortality or serious morbidity (composite outcome), cerebral palsy or neurosensory disability. For maternal outcomes, women allocated to intermittent electronic fetal monitoring (EFM) (CTG) had higher rates of caesarean section for fetal distress (RR 2.92, 95% CI 1.78 to 4.80, 633 women, moderate-quality evidence) compared with women allocated to routine Pinard. There was no clear difference between groups in instrumental vaginal births (RR 1.46, 95% CI 0.86 to 2.49, low-quality evidence). Other outcomes were not reported (maternal mortality, instrumental vaginal birth for fetal distress and or acidosis, analgesia in labour, mobility or restriction during labour, and postnatal depression). Doppler ultrasonography with routine Pinard (two trials)There was no clear difference between groups in Apgar scores < seven at five minutes after birth (reported as < six in one of the trials) (average RR 0.76, 95% CI 0.20 to 2.87; two trials, 2598 babies, I2 = 72%, very low-quality evidence); there was high heterogeneity for this outcome. There was no clear difference between groups for perinatal mortality (RR 0.69, 95% CI 0.09 to 5.40; 2597 infants, two studies, very low-quality evidence), or neonatal seizures (RR 0.05, 95% CI 0.00 to 0.91; 627 infants, one study, very low-quality evidence). Other important infant outcomes were not reported (cord blood acidosis, composite of mortality and serious morbidity, cerebral palsy, neurosensory disability). Only one study reported maternal outcomes. Women allocated to Doppler ultrasonography had higher rates of caesarean section for fetal distress compared with those allocated to routine Pinard (RR 2.71, 95% CI 1.64 to 4.48, 627 women, moderate-quality evidence). There was no clear difference in instrumental vaginal births between groups (RR 1.35, 95% CI 0.78 to 2.32, 627 women, low-quality evidence). Other maternal outcomes were not reported. Intensive Pinard versus routine Pinard (one trial)One trial compared intensive Pinard (a research midwife following the protocol in a one-to-one care situation) with routine Pinard (as per protocol but midwife may be caring for more than one woman in labour). There was no clear difference between groups in low Apgar score (reported as < six this trial) (RR 0.90, 95% CI 0.35 to 2.31, 625 babies, very low-quality evidence). There were also no clear differences identified for perinatal mortality (RR 0.56, 95% CI 0.19 to 1.67; 625 infants, very low-quality evidence), or neonatal seizures (RR 0.68, 95% CI 0.24 to 1.88, 625 infants, very low-quality evidence)). Other infant outcomes were not reported. For maternal outcomes, there were no clear differences between groups for caesarean section or instrumental delivery (RR 0.70, 95% CI 0.35 to 1.38, and RR 1.21, 95% CI 0.69 to 2.11, respectively, 625 women, both low-quality evidence)) Other outcomes were not reported. AUTHORS' CONCLUSIONS Using a hand-held (battery and wind-up) Doppler and intermittent CTG with an abdominal transducer without paper tracing for IA in labour was associated with an increase in caesarean sections due to fetal distress. There was no clear difference in neonatal outcomes (low Apgar scores at five minutes after birth, neonatal seizures or perinatal mortality). Long-term outcomes for the baby (including neurodevelopmental disability and cerebral palsy) were not reported. The quality of the evidence was assessed as moderate to very low and several important outcomes were not reported which means that uncertainty remains regarding the use of IA of FHR in labour.As intermittent CTG and Doppler were associated with higher rates of caesarean sections compared with routine Pinard monitoring, women, health practitioners and policy makers need to consider these results in the absence of evidence of short- and long-term benefits for the mother or baby.Large high-quality randomised trials, particularly in low-income settings, are needed. Trials should assess both short- and long-term health outcomes, comparing different monitoring tools and timing for IA.
Collapse
Affiliation(s)
- Ruth Martis
- The University of AucklandLiggins InstitutePark RoadGraftonAucklandNew Zealand1142
| | - Ova Emilia
- Universitas Gadjah MadaDepartment of Obstetrics and Gynaecology, Faculty of MedicineJl. Farmako, SekipYogyakartaDaerah Istimewa YogyakartaIndonesia55281
| | - Detty S Nurdiati
- Universitas Gadjah MadaDepartment of Obstetrics and Gynaecology, Faculty of MedicineJl. Farmako, SekipYogyakartaDaerah Istimewa YogyakartaIndonesia55281
| | - Julie Brown
- The University of AucklandLiggins InstitutePark RoadGraftonAucklandNew Zealand1142
| | | |
Collapse
|
2
|
Kwon JY, Park IY. Fetal heart rate monitoring: from Doppler to computerized analysis. Obstet Gynecol Sci 2016; 59:79-84. [PMID: 27004196 PMCID: PMC4796090 DOI: 10.5468/ogs.2016.59.2.79] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2015] [Revised: 11/17/2015] [Accepted: 11/17/2015] [Indexed: 11/08/2022] Open
Abstract
The monitoring of fetal heart rate (FHR) status is an important method to check well-being of the baby during labor. Since the electronic FHR monitoring was introduced 40 years ago, it has been expected to be an innovative screening test to detect fetuses who are becoming hypoxic and who may benefit from cesarean delivery or operative vaginal delivery. However, several randomized controlled trials have failed to prove that electronic FHR monitoring had any benefit of reducing the perinatal mortality and morbidity. Also it is now clear that the FHR monitoring had high intra- and interobserver disagreements and increased the rate of cesarean delivery. Despite such limitations, the FHR monitoring is still one of the most important obstetric procedures in clinical practice, and the cardiotocogram is the most-used equipment. To supplement cardiotocogram, new methods of computerized FHR analysis and electrocardiogram have been developed, and several clinical researches have been currently performed. Computerized equipment makes us to analyze beat-to-beat variability and short term heart rate patterns. Furthermore, researches about multiparameters of FHR variability will be ongoing.
Collapse
Affiliation(s)
- Ji Young Kwon
- Department of Obstetrics and Gynecology, The Catholic University of Korea College of Medicine, Seoul, Korea
| | - In Yang Park
- Department of Obstetrics and Gynecology, The Catholic University of Korea College of Medicine, Seoul, Korea
| |
Collapse
|
3
|
Xu A, Durosier LD, Ross MG, Hammond R, Richardson BS, Frasch MG. Adaptive brain shut-down counteracts neuroinflammation in the near-term ovine fetus. Front Neurol 2014; 5:110. [PMID: 25071698 PMCID: PMC4074896 DOI: 10.3389/fneur.2014.00110] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2014] [Accepted: 06/13/2014] [Indexed: 11/18/2022] Open
Abstract
Objective: Repetitive umbilical cord occlusions (UCOs) in ovine fetus leading to severe acidemia result in adaptive shut-down of electrocortical activity [electrocorticogram (ECoG)] as well as systemic and brain inflammation. We hypothesized that the fetuses with earlier ECoG shut-down as a neuroprotective mechanism in response to repetitive UCOs will show less brain inflammation and, moreover, that chronic hypoxia will impact this relationship. Methods: Near-term fetal sheep were chronically instrumented with ECoG leads, vascular catheters, and a cord occluder and then underwent repetitive UCOs for up to 4 h or until fetal arterial pH was <7.00. Eight animals, hypoxic prior to the UCOs (SaO2 <55%), were allowed to recover 24 h post insult, while 14 animals, 5 of whom also were chronically hypoxic, were allowed to recover 48 h post insult, after which brains were perfusion-fixed. Time of ECoG shut-down and corresponding pH were noted, as well as time to then reach pH <7.00 (ΔT). Microglia (MG) were counted as a measure of inflammation in gray matter layers 4–6 (GM4–6) where most ECoG activity is generated. Results are reported as mean ± SEM for p < 0.05. Results: Repetitive UCOs resulted in worsening acidosis over 3–4 h with arterial pH decreasing to 6.97 ± 0.02 all UCO groups’ animals, recovering to baseline by 24 h. ECoG shut-down occurred 52 ± 7 min before reaching pH <7.00 at pH 7.23 ± 0.02 across the animal groups. MG counts were inversely correlated to ΔT in 24 h recovery animals (R = −0.84), as expected. This was not the case in normoxic 48 h recovery animals, and, surprisingly, in hypoxic 48 h recovery animals, this relationship was reversed (R = 0.90). Conclusion: Adaptive brain shut-down during labor-like worsening acidemia counteracts neuroinflammation in a hypoxia- and time-dependent manner.
Collapse
Affiliation(s)
- Alex Xu
- Department of Obstetrics and Gynecology, Western University , London, ON , Canada
| | - Lucien Daniel Durosier
- Department of Obstetrics and Gynaecology and Department of Neurosciences, CHU Sainte-Justine Centre de Recherche, Université de Montréal , Montréal, QC , Canada
| | - Michael G Ross
- Department of Obstetrics and Gynecology, LA BioMed at Harbor-UCLA Medical Center , Torrance, CA , USA
| | - Robert Hammond
- Department of Pathology, Western University , London, ON , Canada
| | - Bryan S Richardson
- Department of Obstetrics and Gynecology, Western University , London, ON , Canada
| | - Martin G Frasch
- Department of Obstetrics and Gynaecology and Department of Neurosciences, CHU Sainte-Justine Centre de Recherche, Université de Montréal , Montréal, QC , Canada
| |
Collapse
|
4
|
Reeves I, Rosario G, Young M, Lewis K, Washington K, Millis RM. Hemodynamic correlates of low umbilical cord vitamin D and ionized calcium. Clin Exp Hypertens 2013; 36:459-64. [PMID: 24164451 DOI: 10.3109/10641963.2013.846361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Vitamin D deficiency and hypocalcemia are associated with gestational hypertension. Therefore, we hypothesized that umbilical cord [Ca(2+)] and [vitamin D] are correlated with perinatal blood pressures. Mothers and newborns comprised vitamin D sufficient (vitamin D ≥ 50 nM, range 52-111 nM, n = 14), and vitamin D deficient groups (vitamin D < 50 nM, range 13-49 nM, n = 29). Cord [Ca²⁺] was negatively correlated with maternal systolic pressure (SBP) (r = -0.56, p < 0.01) and positively correlated with neonatal SBP (r = +0.55, p < 0.01) in the vitamin D deficient group. We conclude that low umbilical cord [vitamin D] and [Ca²⁺] may predispose mothers to higher and newborns to lower blood pressures.
Collapse
Affiliation(s)
- Inez Reeves
- Division of Neonatology, Department of Pediatrics and Child Health
| | | | | | | | | | | |
Collapse
|
5
|
Bugg GJ, Siddiqui F, Thornton JG. Oxytocin versus no treatment or delayed treatment for slow progress in the first stage of spontaneous labour. Cochrane Database Syst Rev 2013:CD007123. [PMID: 23794255 DOI: 10.1002/14651858.cd007123.pub3] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
BACKGROUND Slow progress in the first stage of spontaneous labour is associated with an increased caesarean section rate and fetal and maternal morbidity. Oxytocin has long been advocated as a treatment for slow progress in labour but it is unclear to what extent it improves the outcomes for that labour and whether it actually reduces the caesarean section rate or maternal and fetal morbidity. This review will address the use of oxytocin and whether it improves the outcomes for women who are progressing slowly in labour compared to situations where it is not used or where its administration is delayed. OBJECTIVES To determine if the use of oxytocin for the treatment of slow progress in the first stage of spontaneous labour is associated with a reduction in the incidence of caesarean sections, or maternal and fetal morbidity compared to situations where it is not used or where its administration is delayed. SEARCH METHODS We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (23 February 2013) and bibliographies of relevant papers. SELECTION CRITERIA Randomised controlled trials which compared oxytocin with either placebo, no treatment or delayed oxytocin in the active stage of spontaneous labour in low-risk women at term. DATA COLLECTION AND ANALYSIS Two authors independently assessed studies for inclusion, assessed risk of bias and extracted data. We sought additional information from trial authors. MAIN RESULTS We included eight studies in the review involving a total of 1338 low-risk women in the first stage of spontaneous labour at term. Two comparisons were made; 1) the use of oxytocin versus placebo or no treatment (three trials); 2) the early use of oxytocin versus its delayed use (five trials). There were no significant differences in the rates of caesarean section or instrumental vaginal delivery in either comparison. Early use of oxytocin resulted in an increase in uterine hyperstimulation associated with fetal heart changes. However, the early use of oxytocin versus its delayed use resulted in no significant differences in a range of neonatal and maternal outcomes. Use of early oxytocin resulted in a statistically significant reduction in the mean duration in labour of approximately two hours but did not increase the normal delivery rate. There was significant heterogeneity for this analysis and we carried out a random-effects meta-analysis; however, all of the trials are strongly in the same direction so it is reasonable to conclude that this is the true effect. We also performed a random-effects meta-analysis for the four other analyses which showed substantial heterogeneity in the review. AUTHORS' CONCLUSIONS For women making slow progress in spontaneous labour, treatment with oxytocin as compared with no treatment or delayed oxytocin treatment did not result in any discernable difference in the number of caesarean sections performed. In addition there were no detectable adverse effects for mother or baby. The use of oxytocin was associated with a reduction in the time to delivery of approximately two hours which might be important to some women. However, if the primary goal of this treatment is to reduce caesarean section rates, then doctors and midwives may have to look for alternative options.
Collapse
Affiliation(s)
- George J Bugg
- Department of Obstetrics and Gynaecology, Nottingham University Hospitals NHS Trust, Nottingham,
| | | | | |
Collapse
|
6
|
Alfirevic Z, Devane D, Gyte GML. Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour. Cochrane Database Syst Rev 2013:CD006066. [PMID: 23728657 DOI: 10.1002/14651858.cd006066.pub2] [Citation(s) in RCA: 97] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
BACKGROUND Cardiotocography (known also as electronic fetal monitoring), records changes in the fetal heart rate and their temporal relationship to uterine contractions. The aim is to identify babies who may be short of oxygen (hypoxic), so additional assessments of fetal well-being may be used, or the baby delivered by caesarean section or instrumental vaginal birth. OBJECTIVES To evaluate the effectiveness of continuous cardiotocography during labour. SEARCH METHODS We searched the Cochrane Pregnancy and Childbirth Group Trials Register (31 December 2012) and reference lists of retrieved studies. SELECTION CRITERIA Randomised and quasi-randomised controlled trials involving a comparison of continuous cardiotocography (with and without fetal blood sampling) with (a) no fetal monitoring, (b) intermittent auscultation (c) intermittent cardiotocography. DATA COLLECTION AND ANALYSIS Two review authors independently assessed study eligibility, quality and extracted data from included studies. MAIN RESULTS Thirteen trials were included with over 37,000 women; only two were judged to be of high quality.Compared with intermittent auscultation, continuous cardiotocography showed no significant improvement in overall perinatal death rate (risk ratio (RR) 0.86, 95% confidence interval (CI) 0.59 to 1.23, n = 33,513, 11 trials), but was associated with a halving of neonatal seizures (RR 0.50, 95% CI 0.31 to 0.80, n = 32,386, nine trials). There was no significant difference in cerebral palsy rates (RR 1.75, 95% CI 0.84 to 3.63, n = 13,252, two trials). There was a significant increase in caesarean sections associated with continuous cardiotocography (RR 1.63, 95% CI 1.29 to 2.07, n = 18,861, 11 trials). Women were also more likely to have an instrumental vaginal birth (RR 1.15, 95% CI 1.01 to 1.33, n = 18,615, 10 trials).Data for subgroups of low-risk, high-risk, preterm pregnancies and high-quality trials were consistent with overall results. Access to fetal blood sampling did not appear to influence the difference in neonatal seizures nor any other prespecified outcome. AUTHORS' CONCLUSIONS Continuous cardiotocography during labour is associated with a reduction in neonatal seizures, but no significant differences in cerebral palsy, infant mortality or other standard measures of neonatal well-being. However, continuous cardiotocography was associated with an increase in caesarean sections and instrumental vaginal births. The challenge is how best to convey these results to women to enable them to make an informed choice without compromising the normality of labour.
Collapse
Affiliation(s)
- Zarko Alfirevic
- Department of Women’s and Children’s Health, The University of Liverpool, Liverpool, UK.
| | | | | |
Collapse
|
7
|
Frasch MG, Keen AE, Gagnon R, Ross MG, Richardson BS. Monitoring fetal electrocortical activity during labour for predicting worsening acidemia: a prospective study in the ovine fetus near term. PLoS One 2011; 6:e22100. [PMID: 21789218 PMCID: PMC3137606 DOI: 10.1371/journal.pone.0022100] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2011] [Accepted: 06/16/2011] [Indexed: 11/19/2022] Open
Abstract
Background Severe fetal acidemia during labour with arterial pH below 7.00 is associated with increased risk of hypoxic-ischemic brain injury. Electronic fetal heart rate (FHR) monitoring, the mainstay of intrapartum surveillance, has poor specificity for detecting fetal acidemia. We studied brain electrical activity measured with electrocorticogram (ECOG) in the near term ovine fetus subjected to repetitive umbilical cord occlusions (UCO) inducing FHR decelerations, as might be seen in human labour, to delineate the time-course for ECOG changes with worsening acidemia and thereby assess the potential clinical utility of fetal ECOG. Methodology/Principal Findings Ten chronically catheterized fetal sheep were studied through a series of mild, moderate and severe UCO until the arterial pH was below 7.00. At a pH of 7.24±0.04, 52±13 min prior to the pH dropping <7.00, spectral edge frequency (SEF) increased to 23±2 Hz from 3±1 Hz during each FHR deceleration (p<0.001) and was correlated to decreases in FHR and in fetal arterial blood pressure during each FHR deceleration (p<0.001). Conclusions/Significance The UCO-related changes in ECOG occurred in advance of the pH decreasing below 7.00. These ECOG changes may be a protective mechanism suppressing non-essential energy needs when oxygen supply to the fetal brain is decreased acutely. By detecting such “adaptive brain shutdown,” the need for delivery in high risk pregnant patients may be more accurately predicted than with FHR monitoring alone. Therefore, monitoring fetal electroencephalogram (EEG, the human equivalent of ECOG) during human labour may be a useful adjunct to FHR monitoring.
Collapse
Affiliation(s)
- Martin G Frasch
- Department of Obstetrics and Gynecology, Lawson Health Research Institute, The University of Western Ontario, London, Ontario, Canada.
| | | | | | | | | |
Collapse
|
8
|
Bugg GJ, Siddiqui F, Thornton JG. Oxytocin versus no treatment or delayed treatment for slow progress in the first stage of spontaneous labour. Cochrane Database Syst Rev 2011:CD007123. [PMID: 21735408 DOI: 10.1002/14651858.cd007123.pub2] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
BACKGROUND Slow progress in the first stage of spontaneous labour is associated with an increased caesarean section rate and fetal and maternal morbidity. Oxytocin has long been advocated as a treatment for slow progress in labour but it is unclear to what extent it improves the outcomes for that labour and whether it actually reduces the caesarean section rate or maternal and fetal morbidity. This review will address the use of oxytocin and whether it improves the outcomes for women who are progressing slowly in labour compared to situations where it is not used or where its administration is delayed. OBJECTIVES To determine if the use of oxytocin for the treatment of slow progress in the first stage of spontaneous labour is associated with a reduction in the incidence of caesarean sections, or maternal and fetal morbidity compared to situations where it is not used or where its administration is delayed. SEARCH STRATEGY We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 April 2011) and bibliographies of relevant papers. SELECTION CRITERIA Randomised controlled trials which compared oxytocin with either placebo, no treatment or delayed oxytocin in the active stage of spontaneous labour in low-risk women at term. DATA COLLECTION AND ANALYSIS Two authors independently assessed studies for inclusion, assessed risk of bias and extracted data. We sought additional information from trial authors. MAIN RESULTS We included eight studies in the review involving a total of 1338 low-risk women in the first stage of spontaneous labour at term. Two comparisons were made; 1) the use of oxytocin versus placebo or no treatment (three trials); 2) the early use of oxytocin versus its delayed use (five trials). There were no significant differences in the rates of caesarean section or instrumental vaginal delivery in either comparison. Early use of oxytocin resulted in an increase in uterine hyperstimulation associated with fetal heart changes. However, the early use of oxytocin versus its delayed use resulted in no significant differences in a range of neonatal and maternal outcomes. Use of early oxytocin resulted in a statistically significant reduction in the mean duration in labour of approximately two hours but did not increase the normal delivery rate. There was significant heterogeneity for this analysis and we carried out a random-effects meta-analysis; however, all of the trials are strongly in the same direction so it is reasonable to conclude that this is the true effect. We also performed a random-effects meta-analysis for the four other analyses which showed substantial heterogeneity in the review. AUTHORS' CONCLUSIONS For women making slow progress in spontaneous labour, treatment with oxytocin as compared with no treatment or delayed oxytocin treatment did not result in any discernable difference in the number of caesarean sections performed. In addition there were no detectable adverse effects for mother or baby. The use of oxytocin was associated with a reduction in the time to delivery of approximately two hours which might be important to some women. However, if the primary goal of this treatment is to reduce caesarean section rates, then doctors and midwives may have to look for alternative options.
Collapse
Affiliation(s)
- George J Bugg
- Department of Obstetrics and Gynaecology, Nottingham University Hospitals NHS Trust, Queen's Medical Centre Campus, Derby Road, Nottingham, UK, NG12 4AA
| | | | | |
Collapse
|
9
|
Martis R, Emilia O, Nurdiati DS. Intermittent auscultation (IA) of fetal heart rate in labour for fetal well-being. Cochrane Database Syst Rev 2010. [DOI: 10.1002/14651858.cd008680] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
10
|
Devane D, Lalor JG, Daly S, McGuire W, Smith V. Cardiotocography versus intermittent auscultation of fetal heart on admission to labour ward for assessment of fetal wellbeing. THE COCHRANE DATABASE OF SYSTEMATIC REVIEWS 2010. [DOI: 10.1002/14651858.cd005122.pub3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
11
|
Pinchefsky E, Al-Macki N, Shevell M. Term intra-partum asphyxia: an analysis of acute non-specific supportive criteria and non-CNS organ injury. Eur J Paediatr Neurol 2010; 14:313-9. [PMID: 19811936 DOI: 10.1016/j.ejpn.2009.09.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/05/2009] [Revised: 09/01/2009] [Accepted: 09/03/2009] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The purpose of this study was to describe the frequencies and relationships of non-specific non-essential diagnostic criteria and non-CNS organ system injury in term intra-partum asphyxia. METHODS All children with term intra-partum asphyxia encountered in a single pediatric neurology practice with at least two years follow-up and an abnormal neurologic outcome were identified. RESULTS A total of 40 children (28 males, 12 females) were identified. Twenty-four had moderate NE and sixteen severe NE. The mean number of non-specific non-essential diagnostic criteria (out of a possible 7) was 4.75+/-1.39 SD. Sixty percent had five or more criteria and all criteria were present in only 10% of newborns. The mean number of non-CNS organ systems affected was 2.88+/-1.96 SD (out of a possible 6). Ten percent of our sample showed no evident non-CNS organ injury acutely. CONCLUSION Most asphyxiated neonates failed to consistently satisfy all elements of present consensus statements.
Collapse
Affiliation(s)
- Elana Pinchefsky
- Faculty of Medicine, McGill University, Montreal, Quebec, Canada
| | | | | |
Collapse
|
12
|
Di Napoli A, Di Lallo D, Franco F, Scapillati ME, Zocchetti C, Agostino R, Orzalesi M. Access to level III perinatal care for pregnancies of very short duration (<32 weeks). J Perinat Med 2010; 37:236-43. [PMID: 19196214 DOI: 10.1515/jpm.2009.049] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
AIMS To evaluate to which extent pregnancies of very short duration (<32 weeks' gestation) are concentrated in level III centers. METHODS Area-based study in the 57 maternity units of the Lazio Region (Italy), years 2003-2004, including: 1012 live births (gestational age 22-31 weeks), 261 fetal losses (22-31 weeks) and 209 induced abortions (22-25 weeks). Variables associated with access to a level III unit were evaluated through multivariable logistic regression models. RESULTS 83.7% of all pregnancies <32 weeks (88.8% of live births, 71.6% of fetal losses and 75.1% of induced abortions) were admitted to a level III perinatal center; 23.4% of live newborns, delivered in a level III hospital, were subsequently transferred to a same level facility. The probability that a fetal loss was not treated in a level III perinatal unit was higher for women without pregnancy complication, with lower education level, and living outside the metropolitan area. CONCLUSIONS Regionalization of perinatal care in Lazio is not satisfactory. Concentration of high-risk deliveries in level III centers is good, but in utero transfer is insufficient. This study can help to define the effectiveness of different organizational systems on access to locally available perinatal facilities and to optimize general organizational patterns of perinatal care.
Collapse
|
13
|
Gourounti K, Sandall J. Admission cardiotocography versus intermittent auscultation of fetal heart rate: Effects on neonatal Apgar score, on the rate of caesarean sections and on the rate of instrumental delivery—A systematic review. Int J Nurs Stud 2007; 44:1029-35. [DOI: 10.1016/j.ijnurstu.2006.06.002] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2005] [Revised: 05/29/2006] [Accepted: 06/18/2006] [Indexed: 10/24/2022]
|
14
|
Murphy PA, Fullerton JT. Development of the Optimality Index as a New Approach to Evaluating Outcomes of Maternity Care. J Obstet Gynecol Neonatal Nurs 2006; 35:770-8. [PMID: 17105643 DOI: 10.1111/j.1552-6909.2006.00105.x] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Evaluating perinatal outcomes within a framework of normalcy is a new focus of measurement. As maternal and child health clinicians and researchers look to evaluate care practices that are both of high quality and cost-effective, it is important to have measurement tools that assess differences among all women giving birth. The Optimality Index-US shifts the focus from rare adverse events to evidence-based optimal events. This article describes the continuing development of the index and discusses clinical implications for obstetric nurse clinicians.
Collapse
|
15
|
Alfirevic Z, Devane D, Gyte GML. Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour. Cochrane Database Syst Rev 2006:CD006066. [PMID: 16856111 DOI: 10.1002/14651858.cd006066] [Citation(s) in RCA: 155] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
BACKGROUND Cardiotocography (sometimes known as electronic fetal monitoring), records changes in the fetal heart rate and their temporal relationship to uterine contractions. The aim is to identify babies who may be short of oxygen (hypoxic), so additional assessments of fetal well-being may be used, or the baby delivered by caesarean section or instrumental vaginal birth. OBJECTIVES To evaluate the effectiveness of continuous cardiotocography during labour. SEARCH STRATEGY We searched the Cochrane Pregnancy and Childbirth Group Trials Register (March 2006), CENTRAL (The Cochrane Library 2005, Issue 4), MEDLINE (1966 to December 2005), EMBASE (1974 to December 2005), Dissertation Abstracts (1980 to December 2005) and the National Research Register (December 2005). SELECTION CRITERIA Randomised and quasi-randomised controlled trials involving a comparison of continuous cardiotocography (with and without fetal blood sampling) with (a) no fetal monitoring, (b) intermittent auscultation (c) intermittent cardiotocography. DATA COLLECTION AND ANALYSIS Two authors independently assessed eligibility, quality and extracted data. MAIN RESULTS Twelve trials were included (over 37,000 women); only two were high quality. Compared to intermittent auscultation, continuous cardiotocography showed no significant difference in overall perinatal death rate (relative risk (RR) 0.85, 95% confidence interval (CI) 0.59 to 1.23, n = 33,513, 11 trials), but was associated with a halving of neonatal seizures (RR 0.50, 95% CI 0.31 to 0.80, n = 32,386, nine trials) although no significant difference was detected in cerebral palsy (RR 1.74, 95% CI 0.97 to 3.11, n = 13,252, two trials). There was a significant increase in caesarean sections associated with continuous cardiotocography (RR 1.66, 95% CI 1.30 to 2.13, n =18,761, 10 trials). Women were also more likely to have an instrumental vaginal birth (RR 1.16, 95% CI 1.01 to 1.32, n = 18,151, nine trials). Data for subgroups of low-risk, high-risk, preterm pregnancies and high quality trials were consistent with overall results. Access to fetal blood sampling did not appear to influence the difference in neonatal seizures nor any other prespecified outcome. AUTHORS' CONCLUSIONS Continuous cardiotocography during labour is associated with a reduction in neonatal seizures, but no significant differences in cerebral palsy, infant mortality or other standard measures of neonatal well-being. However, continuous cardiotocography was associated with an increase in caesarean sections and instrumental vaginal births. The real challenge is how best to convey this uncertainty to women to enable them to make an informed choice without compromising the normality of labour.
Collapse
Affiliation(s)
- Z Alfirevic
- University of Liverpool, Division of Perinatal and Reproductive Medicine, First Floor, Liverpool Women's NHS Foundation Trust, Crown Street, Liverpool, UK L8 7SS.
| | | | | |
Collapse
|
16
|
Devane D, Lalor JG, Daly S, McGuire W. Cardiotocography versus intermittent auscultation of fetal heart on admission to labour ward for assessment of fetal wellbeing. THE COCHRANE DATABASE OF SYSTEMATIC REVIEWS 2005. [DOI: 10.1002/14651858.cd005122] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
17
|
Abstract
Despite 40 years of cumulative clinical experience, and a number of randomized clinical trials, electronic fetal heart rate monitoring is perceived by many obstetrical caregivers as a suboptimal method of intrapartum fetal assessment. Fetal pulse oximetry emerged 15 years ago as a promising new technology intended to improve assessment of fetal condition during labor. A large amount of physiologic data and one large randomized clinical trial have brought this technology into clinical practice. We know that fetal acidemia is rare when the arterial oxygen saturation is >30% but fetal pulse oximetry as currently understood and applied does not reduce the overall cesarean rate. Thus, many clinicians remain unconvinced of the benefit of this technology and its utilization has stalled in the US and Europe. We need to further understand if there is a way to use fetal pulse oximetry in the setting of labor dystocia and a non-reassuring fetal heart rate pattern. Although hypoxemia is an accepted mechanism of fetal brain injury, other potential mechanisms should be explored. Current controversies and fertile areas of research are presented.
Collapse
Affiliation(s)
- Gary A Dildy
- School of Medicine, Louisiana State University Health Sciences Center, 1542 Tulane Avenue, New Orleans, LA 70112-2822, USA.
| |
Collapse
|
18
|
Van de Velde M, Teunkens A, Hanssens M, Vandermeersch E, Verhaeghe J. Intrathecal Sufentanil and Fetal Heart Rate Abnormalities: A Double-Blind, Double Placebo-Controlled Trial Comparing Two Forms of Combined Spinal Epidural Analgesia with Epidural Analgesia in Labor. Anesth Analg 2004; 98:1153-1159. [PMID: 15041616 DOI: 10.1213/01.ane.0000101980.34587.66] [Citation(s) in RCA: 86] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
UNLABELLED Combined spinal epidural analgesia (CSE) for labor pain relief has become increasingly popular. However, the effect of intrathecal sufentanil on the incidence of uterine hyperactivity and fetal heart rate (FHR) abnormalities remains controversial. We hypothesized that the use of intrathecal sufentanil in a dose of 7.5 microg is more likely to induce a nonreassuring FHR tracing than a small dose of spinal sufentanil combined with bupivacaine or epidural analgesia. Three-hundred parturients were randomized into three groups. In the first group, epidural analgesia was initiated with 12.5 mg of bupivacaine, 12.5 microg of epinephrine, and 7.5 microg of sufentanil in a volume of 10 mL (EPD group). In Group 2, initial intrathecal analgesia consisted of 2.5 mg of bupivacaine, 2.5 microg of epinephrine, and 1.5 microg of sufentanil (BSE group); in Group 3, spinal analgesia consisted of 7.5 microg of sufentanil (SUF group). Analgesia was maintained in all groups with patient-controlled epidural analgesia using bupivacaine 0.125%, 1.25 microg/mL of epinephrine, and 0.75 microg/mL of sufentanil (bolus, 4 mL; lockout, 15 min). Cardiotocography was monitored continuously 15 min before analgesia and for 60 min after the start of analgesia. The quality of analgesia, labor, and neonatal outcome and side effects were recorded. Twenty-four percent of patients in the SUF group developed FHR abnormalities (bradycardia or late decelerations) during the first hour after initiation of analgesia compared with 12% in the BSE group and 11% in the EPD group. Uterine hyperactivity occurred in 12% of parturients in the SUF group but in only 2% in the other groups. Onset of analgesia was more rapid in both CSE groups as compared with the EPD group. However, 29% of patients in the BSE group developed severe hypotension, requiring IV ephedrine (29% in the BSE group versus 7% and 12% in the EPD and SUF groups, respectively). All these differences reached statistical significance. The present data corroborate previous recommendations of caution when performing CSE using a large dose (7.5 microg or more) of spinal sufentanil because of the risk of uterine hyperactivity and FHR abnormalities. IMPLICATIONS Combined spinal epidural analgesia (CSE) produces pain relief during labor. Fetal heart rate changes after CSE using intrathecal sufentanil have been reported. We performed a randomized, blinded trial confirming that fetal heart rate changes are more frequent after CSE using 7.5 micro g of intrathecal sufentanil as compared with other forms of neuraxial labor analgesia.
Collapse
MESH Headings
- Adult
- Analgesia, Epidural/adverse effects
- Analgesia, Obstetrical/adverse effects
- Analgesia, Patient-Controlled
- Analgesics, Opioid/administration & dosage
- Analgesics, Opioid/adverse effects
- Anesthetics, Local
- Apgar Score
- Bupivacaine
- Dose-Response Relationship, Drug
- Double-Blind Method
- Female
- Heart Rate/drug effects
- Heart Rate, Fetal/drug effects
- Humans
- Infant, Newborn
- Injections, Spinal
- Nerve Block
- Pain Measurement
- Pregnancy
- Pregnancy Outcome
- Sufentanil/administration & dosage
- Sufentanil/adverse effects
- Uterine Contraction/drug effects
Collapse
Affiliation(s)
- M Van de Velde
- Departments of *Anesthesiology and †Obstetrics and Gynecology, University Hospitals Gasthuisberg, Katholieke Universiteit Leuven, Herestraat, Belgium
| | | | | | | | | |
Collapse
|