1
|
Camacho KJ, Tchoul O, Xu Y, Finny A, Kizekai L, McLaughlin J, Byrd S, Addepalli B, Xu M, Lauber M. Bridged Ethylene Polyethylene Oxide Surfaces to Improve Packing Materials for Widepore Size Exclusion Chromatography. J Sep Sci 2024; 47:e202400541. [PMID: 39425498 DOI: 10.1002/jssc.202400541] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2024] [Revised: 09/23/2024] [Accepted: 09/27/2024] [Indexed: 10/21/2024]
Abstract
Here, we describe the preparation of bridged ethylene polyethylene oxide (BE-PEO) surface-modified silica packing materials for size exclusion chromatography. BE-PEO surface-modified silica was hydrolyzed and subsequent 1H nuclear magnetic resonance analysis of hydrolysis products confirmed the successful formation of BE-PEO bonded surface. Silica particles exhibiting 3 µm diameters and 1000 Å nominal pore diameters were selected as a base material for this work out of the critical need to improve analytical capabilities for the testing of cell and gene therapy drug products. Accelerated high pH aging study revealed significant enhancement in column stability. Multi-angle light scattering noise measurements showed inordinately lower baseline noise. Moreover, we evaluated the chromatographic performance of BE-PEO silica-packed columns through separations of a protein test mixture, DNA ladder, monoclonal antibody-based therapeutics, and adeno-associated viruses. BE-PEO silica columns demonstrated high resolution, high recovery separations that were confirmed to be reproducible and capable of extended column lifetimes and exhibited low ionic and hydrophobic secondary interactions. In summary, BE-PEO silica particles have yielded a new level of performance, improved base stability, and inherently lower baseline noise. These novel widepore particles will facilitate more sensitive size-based detection and characterization of large biologics in the form of advanced gene therapy products.
Collapse
Affiliation(s)
| | - Oksana Tchoul
- Consumables and Lab Automation, Waters Corporation, Milford, Massachusetts, USA
| | - Yuehong Xu
- Consumables and Lab Automation, Waters Corporation, Milford, Massachusetts, USA
| | - Abraham Finny
- Consumables and Lab Automation, Waters Corporation, Milford, Massachusetts, USA
| | - Lavelay Kizekai
- Consumables and Lab Automation, Waters Corporation, Milford, Massachusetts, USA
| | - Justin McLaughlin
- Consumables and Lab Automation, Waters Corporation, Milford, Massachusetts, USA
| | - Steven Byrd
- Consumables and Lab Automation, Waters Corporation, Milford, Massachusetts, USA
| | | | - MingCheng Xu
- Consumables and Lab Automation, Waters Corporation, Milford, Massachusetts, USA
| | - Matthew Lauber
- Consumables and Lab Automation, Waters Corporation, Milford, Massachusetts, USA
| |
Collapse
|
2
|
Haseeb A, Fernandes MX, Samuelsson J. Modelling the pH dependent retention and competitive adsorption of charged and ionizable solutes in mixed-mode and reversed-phase liquid chromatography. J Chromatogr A 2024; 1730:465058. [PMID: 38876077 DOI: 10.1016/j.chroma.2024.465058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2024] [Revised: 06/04/2024] [Accepted: 06/06/2024] [Indexed: 06/16/2024]
Abstract
This study investigated the influence of pH on the retention of solutes using a mixed-mode column with carboxyl (-COOH) groups acting as weak cation exchanger bonded to the terminal of C18 ligands (C18-WCX column) and a traditional reversed-phase C18 column. First, a model based on electrostatic theory was derived and successfully used to predict the retention of charged solutes (charged, and ionizable) as a function of mobile phase pH on a C18-WCX column. While the Horváth model predicts the pH-dependent retention of ionizable solutes in reversed-phase liquid chromatography (RPLC) solely based on solute ionization, the developed model incorporates the concept of surface potential generated on the surface of the stationary phase and its variation with pH. To comprehensively understand the adsorption process, adsorption isotherms for these solutes were individually acquired on the C18-WCX and reversed-phase C18 columns. The adsorption isotherms followed the Langmuir model for the uncharged solute and the electrostatically modified Langmuir model for charged solutes. The elution profiles for the single components were calculated from these isotherms using the equilibrium dispersion column model and were found to be in close agreement with the experimental elution profiles. To enable modelling of two-component cases involving charged solute(s), a competitive adsorption isotherm model based on electrostatic theory was derived. This model was later successfully used to calculate the elution profiles of two components for scenarios involving (a) a C18 Column: two charged solutes, (b) a C18 Column: one charged and one uncharged solute, and (c) a C18-WCX Column: two charged solutes. The strong alignment between the experimental and calculated elution profiles in all three scenarios validated the developed competitive adsorption model.
Collapse
Affiliation(s)
- Abdul Haseeb
- Department of Engineering and Chemical Sciences, Karlstad University, SE-651 88 Karlstad, Sweden
| | - Miguel Xavier Fernandes
- Department of Engineering and Chemical Sciences, Karlstad University, SE-651 88 Karlstad, Sweden
| | - Jörgen Samuelsson
- Department of Engineering and Chemical Sciences, Karlstad University, SE-651 88 Karlstad, Sweden.
| |
Collapse
|
3
|
Nilsson JM, Balgoma D, Pettersson C, Lennernäs H, Heindryckx F, Hedeland M. Ammonium bicarbonate buffers combined with hybrid surface technology columns improve the peak shape of strongly tailing lipids. Anal Chim Acta 2024; 1316:342811. [PMID: 38969401 DOI: 10.1016/j.aca.2024.342811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2024] [Revised: 05/30/2024] [Accepted: 05/31/2024] [Indexed: 07/07/2024]
Abstract
BACKGROUND Lipids such as phosphatidic acids (PAs) and cardiolipins (CLs) present strongly tailing peaks in reversed phase liquid chromatography, which entails low detectability. They are usually analyzed by hydrophilic interaction liquid chromatography (HILIC), which hampers high-throughput lipidomics. Thus, there is a great need for improved analytical methods in order to obtain a broader coverage of the lipidome in a single chromatographic method. We investigated the effect of ammonium bicarbonate (ABC) on peak asymmetry and detectability, in comparison with ammonium formate (AFO) on both a conventional BEH C18 column and an HST-CSH C18 column. RESULTS The combination of 2.5 mM ABC buffer pH 8 with an HST-CSH C18 column produced significantly improved results, reducing the asymmetry factor at 10 % peak height of PA 16:0/18:1 from 8.4 to 1.6. Furthermore, on average, there was up to a 54-fold enhancement in the peak height of its [M - H]- ion compared to AFO and the BEH C18 column. We confirmed this beneficial effect on other strongly tailing lipids, with accessible phosphate moieties e.g., cardiolipins, phosphatidylinositol phosphate, phosphatidylinositol bisphosphate, phosphorylated ceramide and phosphorylated sphingosine. Furthermore, we found an increased detectability of phospho- and sphingolipids up to 28 times in negative mode when using an HST-CSH C18 column. The method was successfully applied to mouse liver samples, where previously undetected endogenous phospholipids could be analyzed with improved chromatographic separation. SIGNIFICANCE In conclusion, the use of 2.5 mM ABC substantially improved the peak shape of PAs and enhanced the detectability of the lipidome in negative mode on an RPLC-ESI-Q-TOF-MS system on both BEH C18 and HST-CSH C18 columns. This method provides a wider coverage of the lipidome with one single injection for future lipidomic applications in negative mode.
Collapse
Affiliation(s)
- Jenny M Nilsson
- Department of Medicinal Chemistry, Uppsala Biomedical Centre, Uppsala University, Box 574, 75123 Uppsala, Sweden
| | - David Balgoma
- Department of Medicinal Chemistry, Uppsala Biomedical Centre, Uppsala University, Box 574, 75123 Uppsala, Sweden; Instituto de Biomedicina y Genética Molecular (IBGM), CSIC-Universidad de Valladolid, C/ Sanz y Forés 3, 47003, Valladolid, Spain
| | - Curt Pettersson
- Department of Medicinal Chemistry, Uppsala Biomedical Centre, Uppsala University, Box 574, 75123 Uppsala, Sweden
| | - Hans Lennernäs
- Department of Pharmaceutical Biosciences, Uppsala Biomedical Centre, Uppsala University, Box 591, 75123 Uppsala, Sweden
| | - Femke Heindryckx
- Department of Medical Cell Biology, Uppsala Biomedical Centre, Uppsala University, Box 571, 75123 Uppsala, Sweden
| | - Mikael Hedeland
- Department of Medicinal Chemistry, Uppsala Biomedical Centre, Uppsala University, Box 574, 75123 Uppsala, Sweden.
| |
Collapse
|
4
|
Yeung D, Spicer V, Zahedi RP, Krokhin OV. Paradigm Shift: Major Role of Ion-Pairing-Dependent Size Exclusion Effects in Bottom-Up Proteomics Reversed-Phase Peptide Separations. Anal Chem 2024; 96:9721-9728. [PMID: 38807522 DOI: 10.1021/acs.analchem.4c02035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/30/2024]
Abstract
Can reversed-phase peptide retention be the same for C8 and C18 columns? or increase for otherwise identical columns with a smaller surface area? Can replacing trifluoroacetic acid (TFA) with formic acid (FA) improve the peak shape? According to our common understanding of peptide chromatography, absolutely not. Surprisingly, a thorough comparison of the peptide separation selectivity of 100 and 120 Å fully porous C18 sorbents to maximize the performance of our in-house proteomics LC-MS/MS setup revealed an unexpectedly higher peptide retentivity for a wider pore packing material, despite it having a smaller surface area. Concurrently, the observed increase in peptide retention─which drives variation in separation selectivity between 100 and 120 Å pore size materials─was more pronounced for smaller peptides. These findings contradict the central dogmas that underlie the development of all peptide RP-HPLC applications: (i) a larger surface area leads to higher retention and (ii) increasing the pore size should benefit the retention of larger analytes. Based on our intriguing findings, we compared reversed-phase high-performance liquid chromatography peptide retention for a total of 20 columns with pore sizes between 60 and 300 Å using FA- and TFA-based eluents. Our results unequivocally attest that the larger size of ion pairs in FA- vs TFA-based eluents leads to the observed impact on selectivity and peptide retention. For FA, peptide retention peaks at 200 Å pore size, compared to between 120 and 200 Å for TFA. However, the decrease in retention for narrow-pore particles is more profound in FA. Our findings suggest that common assumptions about analyte size and accessible surface area should be revisited for ion-pair RP separation of small peptides, typical for proteomic applications that are predominantly applying FA eluents. Hybrid silica-based materials with pore sizes of 130-200 Å should be specifically targeted for bottom-up proteomic applications to obtain both superior peak shape and peptide retentivity. This challenging task of attaining the best RPLC column for proteomics calls for closer collaboration between LC column manufacturers and proteomic LC specialists.
Collapse
Affiliation(s)
- Darien Yeung
- Department of Biochemistry and Medical Genetics, University of Manitoba, 336 BMSB, 745 Bannatyne Avenue, Winnipeg R3E 0J9, Canada
| | - Victor Spicer
- Manitoba Centre for Proteomics and Systems Biology, 799 JBRC, 715 McDermot Avenue, Winnipeg R3E 3P4, Canada
| | - Rene P Zahedi
- Department of Biochemistry and Medical Genetics, University of Manitoba, 336 BMSB, 745 Bannatyne Avenue, Winnipeg R3E 0J9, Canada
- Manitoba Centre for Proteomics and Systems Biology, 799 JBRC, 715 McDermot Avenue, Winnipeg R3E 3P4, Canada
- Department of Internal Medicine, University of Manitoba, 799 JBRC, 715 McDermot Avenue, Winnipeg R3E 3P4, Canada
- Paul Albrechtsen Research Institute, Cancer Care Manitoba, Winnipeg, Manitoba R3E 0 V9, Canada
| | - Oleg V Krokhin
- Manitoba Centre for Proteomics and Systems Biology, 799 JBRC, 715 McDermot Avenue, Winnipeg R3E 3P4, Canada
- Department of Internal Medicine, University of Manitoba, 799 JBRC, 715 McDermot Avenue, Winnipeg R3E 3P4, Canada
- Department of Chemistry, University of Manitoba, 360 Parker Building, 144 Dysart Road, Winnipeg R3T 2N2, Canada
| |
Collapse
|
5
|
Villacrés C, Mizero B, Spicer V, Viner R, Saba J, Patel B, Snovida S, Jensen P, Huhmer A, Krokhin OV. Toward an Ultimate Solution for Peptide Retention Time Prediction: The Effect of Column Temperature on Separation Selectivity. J Proteome Res 2024; 23:1488-1494. [PMID: 38530092 DOI: 10.1021/acs.jproteome.4c00018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/27/2024]
Abstract
We studied the effect of the column temperature on the selectivity of reversed-phase peptide separation in bottom-up proteomics. The number of peptide identifications from 2 h liquid chromatography with tandem mass spectrometry (LC-MS/MS) acquisitions reaches a plateau at 45-55 °C, driven simultaneously by improved separation efficiency, a gradual decrease in peptide retention, and possible on-column degradation of peptides at elevated temperatures. Performing 2D LC-MS/MS acquisitions at 25, 35, 45, and 55 °C resulted in the identification of ∼100,000 and ∼120,000 unique peptides for nonmodified and tandem mass tags (TMT)-labeled samples, respectively. These peptide collections were used to investigate the temperature-driven retention features. The latter is governed by the specific temperature response of individual residues, peptide hydrophobicity and length, and amphipathic helicity. On average, peptide retention decreased by 0.56 and 0.5% acetonitrile for each 10 °C increase for label-free and TMT-labeled peptides, respectively. This generally linear response of retention shifts allowed the extrapolation of predictive models beyond the studied temperature range. Thus, (trap) column cooling from room temperature to 0 °C will allow the retention of an additional 3% of detectable tryptic peptides. Meanwhile, the application of 90 °C would result in the loss of ∼20% of tryptic peptides that were amenable to MS/MS-based identification.
Collapse
Affiliation(s)
- Carina Villacrés
- Manitoba Centre for Proteomics and Systems Biology, Winnipeg R3E 3P4, Canada
| | - Benilde Mizero
- Department of Chemistry, University of Manitoba, Winnipeg R3T 2N2, Canada
| | - Victor Spicer
- Manitoba Centre for Proteomics and Systems Biology, Winnipeg R3E 3P4, Canada
| | - Rosa Viner
- Thermo Fisher Scientific, San Jose, California 95134, United States
| | - Julian Saba
- Thermo Fisher Scientific, San Jose, California 95134, United States
| | | | - Sergei Snovida
- Thermo Fisher Scientific, Rockford, Illinois 61101, United States
| | - Penny Jensen
- Thermo Fisher Scientific, Rockford, Illinois 61101, United States
| | - Andreas Huhmer
- Thermo Fisher Scientific, San Jose, California 95134, United States
| | - Oleg V Krokhin
- Manitoba Centre for Proteomics and Systems Biology, Winnipeg R3E 3P4, Canada
- Department of Chemistry, University of Manitoba, Winnipeg R3T 2N2, Canada
- Department of Internal Medicine, University of Manitoba, Winnipeg R3E 3P4, Canada
| |
Collapse
|
6
|
Walter TH, Yang J. Assessment of the reproducibility of a C 18 bonded phase based on ethylene-bridged hybrid organic/inorganic particles. J Chromatogr A 2024; 1716:464637. [PMID: 38217961 DOI: 10.1016/j.chroma.2024.464637] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Revised: 01/05/2024] [Accepted: 01/07/2024] [Indexed: 01/15/2024]
Abstract
The batch-to-batch reproducibility of an endcapped trifunctional C18 bonded phase based on ethylene-bridged hybrid particles was assessed using a modified version of a chromatographic test developed by Neue and coworkers. The test involves the isocratic separation of six compounds chosen to probe different characteristics of the stationary phase, including hydrophobicity, hydrogen bonding and cation-exchange. The assessment was based on results for a total of 471 batches manufactured and tested over a 19 year time span. The results were compared to those for an endcapped monofunctional C18 bonded phase on silica particles, based on results generated for 246 batches over 29 years. Overall, both stationary phases show similar reproducibility, with relative standard deviations for the relative retentions ranging from 0.1 to 3.2 %.
Collapse
Affiliation(s)
- Thomas H Walter
- Waters Corporation, 34 Maple Street, Milford, MA 01757, USA.
| | - Jun Yang
- Waters Corporation, 34 Maple Street, Milford, MA 01757, USA
| |
Collapse
|
7
|
Tang H, Wang Y, Si S, Li H, Chen DDY. Quantification of perfluorinated compounds in atmospheric particulate shows potential connection with environmental event. J Environ Sci (China) 2024; 136:237-247. [PMID: 37923434 DOI: 10.1016/j.jes.2022.08.036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Revised: 08/28/2022] [Accepted: 08/30/2022] [Indexed: 11/07/2023]
Abstract
A method of quantification of perfluorinated compounds (PFCs) from atmospheric particulate matter (APM) is described. A single step pretreatment method, selective pressurized liquid extraction (SPLE), was developed to reduce the high matrix background and avoid contamination from commonly used multiple sample pretreatment steps. An effective sorbent was selected to purify the PFCs during SPLE, followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS), for quantification of PFCs. Conditions affecting the SPLE efficiency, including temperature, static extraction time, and number of extraction cycles used, were studied. The optimum conditions were found to be 120°C, 10 min, and 3 cycles, respectively. LC-MS/MS method was developed to obtain the optimal sensitivity specific to PFCs. The method detection limits (MDLs) were 0.006 to 0.48 ng/g for the PFCs studied and the linear response range was from 0.1 to 100 ng/g. To ensure accurate values were obtained, each step of the experiment was evaluated and controlled to prevent contamination. The optimized method was tested by performing spiking experiments in natural particulate matter matrices and good rates of recovery and reproducibility were obtained for all target compounds. Finally, the method was successfully used to measure 16 PFCs in the APM samples collected in Beijing over five years from 2015 to 2019. It is observed that some PFCs follow the trend of total PFC changes, and can be attributed to the environment influencing events and policy enforcement, while others don't seem to change as much with time of the year or from year to year.
Collapse
Affiliation(s)
- Hua Tang
- National Institute of Metrology, 18 Beisanhuandonglu, Chaoyang District, Beijing 100029, China.
| | - Ying Wang
- School of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China
| | - Shengling Si
- Si Chuan Zhong Ce Biao Wu Technology Co. Ltd., Sichuan 610052, China
| | - Hongli Li
- School of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China
| | - David Da Yong Chen
- School of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China; Department of Chemistry, University of British Columbia, Vancouver V6T 1Z1, BC, Canada.
| |
Collapse
|
8
|
Further Evaluation of the Base Stability of Hydrophilic Interaction Chromatography Columns Packed with Silica or Ethylene-Bridged Hybrid Particles. SEPARATIONS 2023. [DOI: 10.3390/separations10030175] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/08/2023] Open
Abstract
One of the fundamental attributes of a liquid chromatography column is its stability when exposed to acidic and basic mobile phases. However, there have been relatively few reports to date on the stability of hydrophilic interaction chromatography (HILIC) columns. Here, we report the results of stability evaluations carried out for HILIC columns packed with ethylene-bridged hybrid or silica particles using accelerated conditions, employing a 100% aqueous pH 11.3 ammonium bicarbonate mobile phase at 70 °C. Under these conditions, the primary mode of column failure was a loss of efficiency due to the formation of voids resulting from the hydrolysis of the particles. We investigated the dependence of stability on the surface area of both unbonded and sulfobetaine-bonded ethylene-bridged hybrid stationary phases. The results show a clear trend of stability increasing as the surface area decreases. Several commercially available HILIC columns that are recommended for use with high-pH mobile phases were also evaluated. The results show times to 50% loss of the initial efficiency ranging from 0.3 to 9.9 h. Columns containing unbonded, sulfobetaine-bonded or diol-bonded ethylene-bridged hybrid stationary phases had longer lifetimes than amino-bonded silica or sulfobetaine-bonded, hybrid-coated, superficially porous silica columns.
Collapse
|
9
|
Fekete S, Doneanu C, Addepalli B, Gaye M, Nguyen J, Alden B, Birdsall R, Han D, Isaac G, Lauber M. Challenges and emerging trends in liquid chromatography-based analyses of mRNA pharmaceuticals. J Pharm Biomed Anal 2023; 224:115174. [PMID: 36446261 PMCID: PMC9678211 DOI: 10.1016/j.jpba.2022.115174] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Revised: 11/13/2022] [Accepted: 11/16/2022] [Indexed: 11/23/2022]
Abstract
Lipid encapsulated messenger RNA (LNP mRNA) has garnered a significant amount of interest from the pharmaceutical industry and general public alike. This attention has been catalyzed by the clinical success of LNP mRNA for SARS-CoV-2 vaccination as well as future promises that might be fulfilled by the biotechnology pipeline, such as the in vivo delivery of a CRISPR/Cas9 complex that can edit patient cells to reduce levels of low-density lipoprotein. LNP mRNAs are comprised of various chemically diverse molecules brought together in a sophisticated intermolecular complex. This can make it challenging to achieve thorough analytical characterization. Nevertheless, liquid chromatography is becoming an increasingly relied upon technique for LNP mRNA analyses. Although there have been significant advances in all types of LNP mRNA analyses, this review focuses on recent developments and the possibilities of applying anion exchange (AEX) and ion pairing reversed phase (IP-RP) liquid chromatography for intact mRNAs as well as techniques for oligo mapping analysis, 5' endcap testing and lipid compositional assays.
Collapse
|
10
|
Haseeb A, Rova M, Samuelsson J. Method development for the acquisition of adsorption isotherm of ion pair reagents Tributylamine and Triethylamine in ion pair chromatography. J Chromatogr A 2023; 1687:463687. [PMID: 36470076 DOI: 10.1016/j.chroma.2022.463687] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Revised: 11/25/2022] [Accepted: 11/26/2022] [Indexed: 11/29/2022]
Abstract
Tributylamine (TBuA) and triethylamine (TEtA) are the most commonly used ion pair reagents in ion pair chromatography especially for the analysis of oligonucleotides. In order to improve the understanding of the retention and separation mechanism of oligonucleotides in ion pair chromatography, it is important to understand the retention mechanism and the nature of interaction of these ion pair reagents with the stationary phase in the chromatographic column. Adsorption isotherm is helpful in evaluating such interactions, and subsequently predicting the retention mechanism. Alkylamines are very polar molecules which lack suitable chromophore and are commonly present in charged forms. Therefore, their determination and the subsequent acquisition of their adsorption isotherms using traditional liquid chromatography is very difficult. In this study, we first developed an analytical method for the determination of TBuA and TEtA in a typical chromatographic mobile phase (acetonitrile-water) and then used the same method to acquire the adsorption isotherms for tributylammonium acetate (TBuAA) and triethylammonium acetate (TEtAA). This method started with the conversion of the alkylammonium ions to free neutral forms by treating the sample with a strong base, followed by pentane-mediated extraction and finally the analysis of the extracts using gas chromatography-flame ionization detector (GC-FID). This three-step method was validated for parameters like range, linearity, intra-day and inter-day precision and accuracy, limit of detection and limit of quantitation. For the adsorption isotherms, the C18 column was first equilibrated with the solutions having different concentrations of alkylammonium ions and then stripped with eluent devoid of alkylammonium ions. Several stripping eluents were investigated and it was discovered that the eluent requirement could be decreased by the addition of sodium chloride. The effluents from the stripping phase were collected and analyzed using the developed analytical method to acquire the adsorption data. Under the investigated conditions, adsorption of TBuAA and TEtAA showed type III and type I isotherm behavior respectively.
Collapse
Affiliation(s)
- Abdul Haseeb
- Department of Engineering and Chemical Sciences, Karlstad University, Karlstad SE-651 88, Sweden
| | - Maria Rova
- Department of Engineering and Chemical Sciences, Karlstad University, Karlstad SE-651 88, Sweden
| | - Jörgen Samuelsson
- Department of Engineering and Chemical Sciences, Karlstad University, Karlstad SE-651 88, Sweden.
| |
Collapse
|
11
|
Liu B, Li H, Quan K, Chen J, Qiu H. Periodic mesoporous organosilica for chromatographic stationary phases: From synthesis strategies to applications. Trends Analyt Chem 2023. [DOI: 10.1016/j.trac.2022.116895] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
12
|
Hecht ES, Obiorah EC, Liu X, Morrison L, Shion H, Lauber M. Microflow size exclusion chromatography to preserve micromolar affinity complexes and achieve subunit separations for native state mass spectrometry. J Chromatogr A 2022; 1685:463638. [DOI: 10.1016/j.chroma.2022.463638] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2022] [Revised: 11/02/2022] [Accepted: 11/04/2022] [Indexed: 11/09/2022]
|
13
|
A method of isolating and analysing drugs from cancer cells for preclinical research. J Chromatogr A 2022; 1682:463500. [PMID: 36162249 DOI: 10.1016/j.chroma.2022.463500] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 09/09/2022] [Accepted: 09/11/2022] [Indexed: 11/23/2022]
Abstract
The presented paper describes a new isolation method of recovery and analysis of selected drugs developed for preclinical research. The method uses the RP-HPLC technique (in a single chromatographic separation) and serves the recovery and analysis of selected drugs from neoplastic cells. It enables the determination of cytostatics statins, fibrates, and pioglitazone. Chromatographic separations of the tested compounds were carried out on a Gemini-NX 5 µ C18 (4.6 × 150 mm i.d.) column, in a gradient system with a mobile phase consisting of ACN (0.1% TFA) and water (0.1% TFA) at ambient temperature. The separations were carried out at a flow of 1 ml/min and UV detection of 220 nm. The inter-day and intra-day precision and accuracy of the method were determined. Extending the extraction time at reduced temperature resulted in a significant increase in the recovery of the pharmaceuticals in comparison with traditional extraction methods. The presence of the tested pharmaceuticals at defined retention times was confirmed by mass spectrometry. A recovery procedure for the tested compounds from biological material (medium, cell pellets) was developed at a level ranging between 93 and 99%. The utility of the new HPLC method has been confirmed in drug absorption studies as screening tests for the analysis of the new therapeutic compositions on melanoma cell lines.
Collapse
|
14
|
Gilar M, Berthelette KD, Walter TH. Contribution of ionic interactions to stationary phase selectivity in hydrophilic interaction chromatography. J Sep Sci 2022; 45:3264-3275. [PMID: 35347885 PMCID: PMC9545918 DOI: 10.1002/jssc.202200165] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Revised: 03/21/2022] [Accepted: 03/24/2022] [Indexed: 11/09/2022]
Abstract
We compared the separation selectivities of 19 different hydrophilic interaction chromatography columns. The stationary phases included underivatized silica and hybrid particles, cyano-bonded silica, materials with neutral ligands such as amide, diol, pentahydroxy, and urea, zwitterionic sorbents, and mixed-mode materials with amine functionalities. A set of 77 small molecules was used to evaluate the columns. We visualized the retention behavior of the different columns using retention time correlation plots. The analytes were classified as cations, anions, or neutral based on their estimated charge under the separation conditions. This involved adjusting the dissociation constants of the analytes for the acetonitrile content of the mobile phase and experimentally determining the pH of the mobile phase containing 70% acetonitrile. The retention correlation plots show that the selectivity differences strongly depended on ionic interactions. Comparisons of the neutral stationary phases (e.g., diol vs. amide) showed more similar selectivity than did comparisons of neutral columns versus columns with cation or anion exchange activity (bare silica or amine columns, respectively). The zwitterionic columns did not behave as perfectly neutral. The correlation plots indicated that they exhibited either cation or anion exchange activity, although to a lesser degree than the silica and amine-containing stationary phases.
Collapse
Affiliation(s)
- Martin Gilar
- Separations R&DWaters CorporationMilfordMassachusettsUSA
| | | | | |
Collapse
|
15
|
Fekete S, Kizekai L, Sarisozen YT, Lawrence N, Shiner S, Lauber M. Investigating the secondary interactions of packing materials for size-exclusion chromatography of therapeutic proteins. J Chromatogr A 2022; 1676:463262. [DOI: 10.1016/j.chroma.2022.463262] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2022] [Revised: 06/14/2022] [Accepted: 06/16/2022] [Indexed: 11/29/2022]
|
16
|
Evaluation of the Base Stability of Hydrophilic Interaction Chromatography Columns Packed with Silica or Ethylene-Bridged Hybrid Particles. SEPARATIONS 2022. [DOI: 10.3390/separations9060146] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/07/2022] Open
Abstract
Stability as a function of mobile phase pH is an important consideration when selecting a chromatographic column. While the pH stability of reversed-phase columns is widely studied, there are relatively few reports of the stability of hydrophilic interaction chromatography (HILIC) columns. We evaluated the stability of silica and ethylene-bridged hybrid HILIC columns when used with mobile phases containing basic buffers. The predominant mode of column degradation observed in our studies was a decrease in efficiency due to voiding, resulting from the hydrolysis of the silica particles. Associated with this were increases in tailing factors. Retention factor changes were also noted but were smaller than the efficiency losses. The dependence of the rate of efficiency decrease on the key variables of temperature, mobile phase pH and water content were studied for an unbonded silica column. The effect of the acetonitrile concentration on the pH of the mixed aqueous/acetonitrile mobile phases was also investigated. Using conditions found to cause a 50% decrease in efficiency after approximately five hours of exposure to the basic solution, we evaluated eight different commercially available HILIC columns containing silica or ethylene-bridged hybrid particles. The results show large differences between the stability of the silica and ethylene-bridged hybrid particle stationary phases, with the latter exhibiting greater stability.
Collapse
|
17
|
Walter TH, Alden BA, Belanger JL, Berthelette K, Boissel C, DeLano M, Kizekai L, Nguyen JM, Shiner SJ. Modifying the Metal Surfaces in HPLC Systems and Columns to Prevent Analyte Adsorption and Other Deleterious Effects. LCGC NORTH AMERICA 2022. [DOI: 10.56530/lcgc.na.pm7270x6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Interactions of certain analytes with metal surfaces in high performance liquid chromatography (HPLC) instruments and columns cause a range of deleterious effects, including peak broadening and tailing, low peak areas, and the formation of new peaks due to chemical reactions. To mitigate these effects, we have developed a novel surface modification technology in which a hybrid organic/inorganic surface based on an ethylene-bridged siloxane chemistry is applied to the metal components in HPLC instruments and columns. We demonstrate the impact of this technology on peak symmetry, peak area, and injection-to-injection and column-to-column reproducibility for several metal-sensitive analytes. We also show an example of the mitigation of an on-column oxidation reaction. A variant of this technology has recently been developed for size-exclusion chromatography of proteins. An example is shown demonstrating the use of this variant applied to size-exclusion columns for the separation of a monoclonal antibody monomer and higher molecular weight species. Together, these results highlight the importance of preventing interactions of analytes with metal surfaces in HPLC in order to achieve accurate and precise results.
Collapse
|
18
|
Fekete S, DeLano M, Harrison AB, Shiner SJ, Belanger JL, Wyndham KD, Lauber MA. Size Exclusion and Ion Exchange Chromatographic Hardware Modified with a Hydrophilic Hybrid Surface. Anal Chem 2022; 94:3360-3367. [PMID: 35143179 DOI: 10.1021/acs.analchem.1c05466] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Certain biomolecules have proven to be difficult to analyze by liquid chromatography (LC), especially under certain chromatographic conditions. The separation of proteins in aqueous mobile phases is one such example because there is the potential for both hydrophobic and ionic secondary interactions to occur with chromatographic hardware to the detriment of peak recovery, peak shape, and the overall sensitivity of the LC analysis. To decrease non-specific adsorption and undesired secondary interactions between column hardware and biomolecules, we have developed and applied a new hydrophilically modified hybrid surface (h-HST) for size exclusion chromatography (SEC) and anion exchange (AEX) separations of proteins and nucleic acids. This surface incorporates additional oxygen and carbon atoms onto an ethylene bridge hybrid siloxane polymer. As a result, it exhibits reduced electrostatic properties and hydrophilicity that facilitates challenging aqueous separations. Flow injection tests with a phosphate buffer showed superior protein recovery from an h-HST frit when compared to unmodified ethylene-bridged hybrid HST, titanium, stainless steel, and PEEK frits. When applied to SEC of rituximab, ramucirumab, and trastuzumab emtansine with a 50 mM ammonium acetate buffer, this new hydrophilic chromatographic hardware yielded improved monomer and aggregate recovery, higher plate numbers, and more symmetrical peaks. AEX columns also benefited from h-HST hardware. An acidic mAb (eculizumab) showed improved recovery, more stable retention, and a sharper peak when eluted from an h-HST versus SS column. Moreover, AEX separations of intact mRNA samples (Cas9 and EPO mRNA) were improved, where it was seen that h-HST column hardware provided higher sensitivity and more repeatable peak areas from injection to injection. As such, there is significant potential in the use of h-HST chromatographic hardware to facilitate more robust and more sensitive analyses for a multitude of challenging separations and analytes.
Collapse
Affiliation(s)
- Szabolcs Fekete
- Waters Corporation, CMU-Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| | - Mathew DeLano
- Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, United States
| | | | - Stephen J Shiner
- Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, United States
| | | | - Kevin D Wyndham
- Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, United States
| | - Matthew A Lauber
- Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, United States
| |
Collapse
|
19
|
Li YS, Wang YT, Tseng WL, Lu CY. Peptide-based chiral derivatizing reagents in nano-scale liquid chromatography: Effect of the oxidation state of cysteine moiety on enantioseparation of ibuprofen. Microchem J 2022. [DOI: 10.1016/j.microc.2021.106933] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
20
|
Walter TH, Alden BA, Berthelette K, Field JA, Lawrence NL, McLaughlin J, Patel AV. Characterization of a highly stable zwitterionic hydrophilic interaction chromatography stationary phase based on hybrid organic/inorganic particles. J Sep Sci 2021; 45:1389-1399. [PMID: 34937126 PMCID: PMC9487986 DOI: 10.1002/jssc.202100859] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Revised: 12/14/2021] [Accepted: 12/16/2021] [Indexed: 11/08/2022]
Abstract
We have characterized a sulfobetaine stationary phase based on 1.7 μm ethylene-bridged hybrid organic/inorganic particles, which is intended for use in hydrophilic interaction chromatography. The efficiency of columns packed with this material were determined as a function of flow rate, demonstrating a minimum reduced plate height of 2.4. The batch-to-batch reproducibility was assessed using the separation of a mixture of acids, bases and neutrals. We compared the retention and selectivity of the hybrid sulfobetaine stationary phase to that of several benchmark materials. The hybrid sulfobetaine material gave strong retention for polar neutrals and high selectivity for methyl groups, hydroxy groups and configurational isomers. Large differences in cation and anion retention were observed among the columns. We characterized the acid and base stability of the hybrid sulfobetaine stationary phase, using accelerated tests at pH 1.3 and 11.0, both at 70°C. The results support a recommended pH range of 2 to 10. We also investigated the performance of columns packed with this material for metal-sensitive analytes, comparing conventional stainless steel column hardware to hardware that incorporates hybrid surface technology to mitigate interactions with metal surfaces. Compared to the conventional columns, the hybrid surface technology columns showed greatly improved peak shape. This article is protected by copyright. All rights reserved.
Collapse
|
21
|
Zhang S, Tang R, Wang D, Ma S, Jia S, Gao Z, Gong B, Ou J. Fabrication of highly crosslinked and monodispersed silicon-containing polymeric microspheres via photo-initiated polymerization and their application in capillary liquid chromatography. J Chromatogr A 2021; 1659:462643. [PMID: 34735962 DOI: 10.1016/j.chroma.2021.462643] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 10/19/2021] [Accepted: 10/21/2021] [Indexed: 11/25/2022]
Abstract
Although inorganic silica-based and polymeric micron-sized spheres have widely been explored as column packing materials in high performance liquid chromatography (HPLC), they are still suffering the problems of either alkali corrosion of silica or polymer swelling. It is still necessary to search simple approaches for fabrication of monodisperse micron-sized hybrid particles as packing materials in HPLC. A novel kind of silicon-containing polyacrylate microspheres was designed and fabricated via two-step swelling and photo-initiated polymerization approach using 3-(allylpropylsilane) propyl acrylate (TAPA) containing both acrylate and vinyl groups and trimethylolpropane triacrylate (TRIM) as precursors. After carefully optimizing the fabrication conditions, the monodisperse micron-sized microspheres could be acquired as chromatographic packing, exhibiting excellent mechanical stability and reproducibility. Due to existence of electron-rich vinyl groups, three kinds of thiols such as octadecanethiol (ODT), dithiothreitol (DTT) and trimethylolpropane tris(3-mercaptopropionate) (TTMP) were facilely anchored onto the surface of microsphere via photo-initiated thiol-ene click reaction. They were applied in the separation of small molecules by cLC-UV and complex biosamples by cLC-MS/MS. A total of 6691 unique peptides from 1771 unique proteins was identified by ODT-modified microsphere, which was higher than those by unmodified and DTT/TTMP-modified poly(TAPA-co-TRIM) microspheres. It was expected this kind of hybrid microspheres can be further modified and widely applied in chromatographic field, offering great potential in commercialization.
Collapse
Affiliation(s)
- Shuai Zhang
- School of Chemistry and Chemical Engineering, Key Laboratory for Chemical Engineering and Technology, State Ethnic Affairs Commission, North Minzu University, Yinchuan, P. R. China; CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
| | - Ruizhi Tang
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
| | | | - Shujuan Ma
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
| | - Shicong Jia
- School of Chemistry and Chemical Engineering, Key Laboratory for Chemical Engineering and Technology, State Ethnic Affairs Commission, North Minzu University, Yinchuan, P. R. China; CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
| | - Zheng Gao
- School of Chemistry and Chemical Engineering, Key Laboratory for Chemical Engineering and Technology, State Ethnic Affairs Commission, North Minzu University, Yinchuan, P. R. China; CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
| | - Bolin Gong
- School of Chemistry and Chemical Engineering, Key Laboratory for Chemical Engineering and Technology, State Ethnic Affairs Commission, North Minzu University, Yinchuan, P. R. China.
| | - Junjie Ou
- School of Chemistry and Chemical Engineering, Key Laboratory for Chemical Engineering and Technology, State Ethnic Affairs Commission, North Minzu University, Yinchuan, P. R. China; CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China; University of Chinese Academy of Sciences, Beijing 100049, China.
| |
Collapse
|
22
|
Nguyen JM, Gilar M, Koshel B, Donegan M, MacLean J, Li Z, Lauber MA. Assessing the impact of nonspecific binding on oligonucleotide bioanalysis. Bioanalysis 2021; 13:1233-1244. [PMID: 34472373 DOI: 10.4155/bio-2021-0115] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Abstract
Aim: Accurate and reliable quantification of oligonucleotides can be difficult, which has led to an increased focus on bioanalytical methods for more robust analyses. Recent advances toward mitigating sample losses on liquid chromatography (LC) systems have produced recovery advantages for oligonucleotide separations. Results & methodology: LC instruments and columns constructed from MP35N metal alloy and stainless steel columns were compared against LC hardware modified with hybrid inorganic-organic silica surfaces. Designed to minimize metal-analyte adsorption, these surfaces demonstrated a 73% increase in 25-mer phosphorothioate oligonucleotide recovery using ion-pairing reversed-phase LC versus standard LC surfaces, most particularly upon initial use. Conclusion: Hybrid silica chromatographic surfaces improve the performance, detection limits and reproducibility of oligonucleotide bioanalytical assays.
Collapse
Affiliation(s)
- Jennifer M Nguyen
- School of Science, University of Copenhagen, Rolighedsvej 30, 1958 Frederiksberg, Denmark
- Waters Corporation, 34 Maple Street, Milford, MA 01757, USA
| | - Martin Gilar
- Waters Corporation, 34 Maple Street, Milford, MA 01757, USA
| | - Brooke Koshel
- Waters Corporation, 34 Maple Street, Milford, MA 01757, USA
| | | | - Jason MacLean
- Waters Corporation, 34 Maple Street, Milford, MA 01757, USA
| | - Zhimin Li
- Waters Corporation, 34 Maple Street, Milford, MA 01757, USA
| | | |
Collapse
|
23
|
Birdsall RE, Kellett J, Ippoliti S, Ranbaduge N, Lauber MA, Yu YQ, Chen W. Reducing metal-ion mediated adsorption of acidic peptides in RPLC-based assays using hybrid silica chromatographic surfaces. J Chromatogr B Analyt Technol Biomed Life Sci 2021; 1179:122700. [PMID: 34329890 DOI: 10.1016/j.jchromb.2021.122700] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Revised: 03/05/2021] [Accepted: 04/02/2021] [Indexed: 10/21/2022]
Abstract
In this study we evaluate column hardware exhibiting a novel hybrid silica surface in its ability to mitigate metal-induced adsorption artifacts such as chromatographic peak tailing for acidic amino acid residue containing peptides. Using a conventional reversed-phase liquid chromatography (RPLC)-based method, chromatographic performance of a peptide map was compared using a traditional stainless-steel column and an equivalent column bearing a novel hybrid silica surface. Tailing factors for six peptides containing acidic amino acid residues (Tf ≥ 1.50) were observed to be reduced up to 80% to a nominal value Tf ≤ 1.2 with R.S.D. % ≤ 4%. Furthermore, recovery for two of the identified peptides exhibited increased recovery in addition to reduced peak tailing when using the column bearing the hybrid silica surface. Performance was unaffected for peaks where there were no implications of metal induced effects. Collectively, this study demonstrates that the novel hybrid silica surface can effectively reduce peak tailing for acidic residue containing peptides.
Collapse
Affiliation(s)
- Robert E Birdsall
- Waters Corporation, 34 Maple Street, Milford, MA 01757, United States.
| | - Jacob Kellett
- Waters Corporation, 34 Maple Street, Milford, MA 01757, United States.
| | - Samantha Ippoliti
- Waters Corporation, 34 Maple Street, Milford, MA 01757, United States.
| | - Nilini Ranbaduge
- Waters Corporation, 34 Maple Street, Milford, MA 01757, United States.
| | - Matthew A Lauber
- Waters Corporation, 34 Maple Street, Milford, MA 01757, United States.
| | - Ying Qing Yu
- Waters Corporation, 34 Maple Street, Milford, MA 01757, United States.
| | - Weibin Chen
- Waters Corporation, 34 Maple Street, Milford, MA 01757, United States.
| |
Collapse
|
24
|
Walter TH, Blaze M. T. M, Boissel C. Electrospray ionization mass spectrometry ion suppression/enhancement caused by column bleed for three mixed-mode reversed-phase/anion-exchange high-performance liquid chromatography columns. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2021; 35:e9098. [PMID: 33830546 PMCID: PMC8244038 DOI: 10.1002/rcm.9098] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Revised: 04/05/2021] [Accepted: 04/06/2021] [Indexed: 06/12/2023]
Abstract
RATIONALE Mixed-mode reversed-phase/anion exchange liquid chromatography is useful for separations of mixtures containing anions (e.g. ionized acids). However, when using this form of liquid chromatography with mass spectrometry detection, the bleed of amine-containing hydrolysis products from the columns may cause ion suppression or enhancement. METHODS Using electrospray ionization tandem quadrupole mass spectrometry detection, we determined the ion suppression or enhancement caused by column bleed for three mixed-mode reversed-phase/weak anion-exchange columns containing stationary phases that differ in chemical structure. Two of the stationary phases are based on silica particles, while the third uses ethylene-bridged hybrid organic/inorganic particles, which have improved hydrolytic stability. Mixtures of acidic and basic analytes were combined with the chromatography flow postcolumn, both with and without a column, and their mass spectrometry ion signal responses (peak areas) were determined. The ratio of signal response with and without a column is the matrix factor. Positive ion electrospray measurements were carried out using 0.1% formic acid (pH ~ 2.7) as a mobile phase additive, and 10mM ammonium formate (pH ~ 6.4) was used for negative ion electrospray detection. RESULTS The matrix factors under both positive and negative ionization modes were closest to 1 (0.74-1.16) for the hybrid particle-based columns, showing minimal ion suppression or enhancement. In contrast, the silica-based columns gave matrix factors ranging from 0.04 to 1.86, indicating high levels of ion suppression or enhancement. These results may be explained by the differences in the structures of the stationary phases, which affect the relative amounts of hydrolysis products that elute from the columns. CONCLUSIONS The low levels of mass spectrometry ion suppression or enhancement caused by column bleed from the hybrid particle-based columns should allow for accurate quantitative mass spectrometric detection combined with mixed-mode reversed-phase/weak anion-exchange chromatography.
Collapse
|
25
|
Tanna N, Mullin LG, Rainville PD, Wilson ID, Plumb RS. Improving LC/MS/MS-based bioanalytical method performance and sensitivity via a hybrid surface barrier to mitigate analyte - Metal surface interactions. J Chromatogr B Analyt Technol Biomed Life Sci 2021; 1179:122825. [PMID: 34218093 DOI: 10.1016/j.jchromb.2021.122825] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 06/01/2021] [Accepted: 06/03/2021] [Indexed: 12/16/2022]
Abstract
The accurate determination of the pharmacokinetics (PK) of a candidate drug molecule is critical in both drug discovery and development. Over the last 30 years, the sensitivity and selectivity of LC/MS has resulted in it being established as the technology of choice for these studies. However, unwanted chemical interactions between analyte(s) and the metal components in a chromatography system can result in poor peak shape and reduction in signal response, which can adversely affect the analysis of low concentrations of drugs and their metabolites in biological samples. This study evaluated the benefits of employing an inert hybrid surface technology (HST) applied to the metallic components in the LC flow path, column frits and column wall to mitigate these interactions. The results obtained were compared with that of an identical conventional LC for the bioanalysis of two steroid phosphate drugs (dexamethasone phosphate and hydrocortisone phosphate) and an epidermal growth factor receptor (EGFR) inhibitor (gefitinib) in human plasma. The results showed that for the two steroid phosphates, the peak width was reduced by 20%, peak tailing factors reduced by up to 30% and the assay sensitivity improved by factors of 7.5 and 10. This resulted in a significant improvement in the limit of detection. The new LC system also improved the reproducibility of peak integration for gefitinib, thereby reducing assay coefficients of variation (%CV) from greater than 10% to less than 5% at the lower limit of quantification.
Collapse
Affiliation(s)
- Nikunj Tanna
- Waters Corporation, 34 Maple St, Milford, MA 01757, USA.
| | - Lauren G Mullin
- Waters Corporation, Stamford Avenue, Altrincham Road, Wilmslow SK9 4AX, UK
| | | | - Ian D Wilson
- Computational and Systems Medicine, Department of Metabolism, Digestion and Reproduction Imperial College, London SW7 2AZ, UK
| | | |
Collapse
|
26
|
Gilar M, DeLano M, Gritti F. Mitigation of analyte loss on metal surfaces in liquid chromatography. J Chromatogr A 2021; 1650:462247. [PMID: 34087520 DOI: 10.1016/j.chroma.2021.462247] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Revised: 04/21/2021] [Accepted: 05/07/2021] [Indexed: 10/21/2022]
Abstract
The adsorptive loss of acidic analytes in liquid chromatography was investigated using metal frits. Repetitive injections of acidic small molecules or an oligonucleotide were made on individual 2.1 or 4.6 mm i.d. column frits. Losses were observed for adenosine 5'-(α,β-methylene) diphosphate, 2-pyridinol 1-oxide and the 25-mer phosphorothioate oligonucleotide Trecovirsen (GEM91) on stainless steel and titanium frits. Analyte adsorption was greatest at acidic pH due to the positive charge on the metal oxide surface. Analyte recovery increased when a series of injections was performed; this effect is known as sample conditioning. Nearly complete recovery was achieved when the metal adsorptive sites were saturated with the analyte. A similar effect was achieved by conditioning the frits with phosphoric, citric or etidronic acids, or their buffered solutions. These procedures can be utilized to mitigate analyte loss. However, the effect is temporary, as the conditioning agent is gradually removed by the running mobile phase. Metal frits modified with hybrid organic/inorganic surface technology were shown to mitigate analyte-to-metal surface interactions and improve recovery of acidic analytes. Quantitative recovery of a 15-35 mer oligodeoxythymidine mixture was achieved using column hardware modified with hybrid surface technology, without a need for column conditioning prior to analysis.
Collapse
Affiliation(s)
- Martin Gilar
- Waters Corporation, 34 Maple Street, Milford, MA 01757, USA.
| | - Mathew DeLano
- Waters Corporation, 34 Maple Street, Milford, MA 01757, USA
| | - Fabrice Gritti
- Waters Corporation, 34 Maple Street, Milford, MA 01757, USA
| |
Collapse
|
27
|
Static vs. Dynamic Electrostatic Repulsion Reversed Phase Liquid Chromatography: Solutions for Pharmaceutical and Biopharmaceutical Basic Compounds. SEPARATIONS 2021. [DOI: 10.3390/separations8050059] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Many efforts have been made to separate basic compounds, which are challenging to resolve in reversed phase liquid chromatography. In this process, they are strongly retained and the peak shape undergoes significant distortion. The principal origin of this has been identified with the non-negligible interaction with residual deprotonated silanols. Consequently, all solutions that efficiently shield silanols are being sought. This review is an upgrade on the use of the electrostatic repulsion reversed phase (ERRP) approach: retention of bases, in protonated form, can be achieved by modulating the charge repulsion caused by the presence of positive charges in the chromatographic system. This study successfully (i) introduced fixed positive charges in the structure of stationary phases, (ii) used cationic and hydrophobic additives in the mobile phase, and (iii) used the ERRP-like approach employed at the preparative level for peptide purification.
Collapse
|
28
|
DeLano M, Walter TH, Lauber MA, Gilar M, Jung MC, Nguyen JM, Boissel C, Patel AV, Bates-Harrison A, Wyndham KD. Using Hybrid Organic-Inorganic Surface Technology to Mitigate Analyte Interactions with Metal Surfaces in UHPLC. Anal Chem 2021; 93:5773-5781. [PMID: 33798331 DOI: 10.1021/acs.analchem.0c05203] [Citation(s) in RCA: 36] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Interactions of analytes with metal surfaces in high-performance liquid chromatography (HPLC) instruments and columns have been reported to cause deleterious effects ranging from peak tailing to a complete loss of the analyte signal. These effects are due to the adsorption of certain analytes on the metal oxide layer on the surface of the metal components. We have developed a novel surface modification technology and applied it to the metal components in ultra-HPLC (UHPLC) instruments and columns to mitigate these interactions. A hybrid organic-inorganic surface, based on an ethylene-bridged siloxane chemistry, was developed for use with reversed-phase and hydrophilic interaction chromatography. We have characterized the performance of UHPLC instruments and columns that incorporate this surface technology and compared the results with those obtained using their conventional counterparts. We demonstrate improved performance when using the hybrid surface technology for separations of nucleotides, a phosphopeptide, and an oligonucleotide. The hybrid surface technology was found to result in higher and more consistent analyte peak areas and improved peak shape, particularly when using low analyte mass loads and acidic mobile phases. Reduced abundances of iron adducts in the mass spectrum of a peptide were also observed when using UHPLC systems and columns that incorporate hybrid surface technology. These results suggest that this technology will be particularly beneficial in UHPLC/mass spectrometry investigations of metal-sensitive analytes.
Collapse
Affiliation(s)
- Mathew DeLano
- Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, United States
| | - Thomas H Walter
- Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, United States
| | - Matthew A Lauber
- Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, United States
| | - Martin Gilar
- Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, United States
| | - Moon Chul Jung
- Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, United States
| | - Jennifer M Nguyen
- Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, United States
| | - Cheryl Boissel
- Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, United States
| | - Amit V Patel
- Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, United States
| | | | - Kevin D Wyndham
- Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, United States
| |
Collapse
|
29
|
Walter TH, Alden BA, Field JA, Lawrence NL, Osterman DL, Patel AV, DeLoffi MA. Characterization of a highly stable mixed-mode reversed-phase/weak anion-exchange stationary phase based on hybrid organic/inorganic particles. J Sep Sci 2021; 44:1005-1014. [PMID: 33354922 PMCID: PMC7986357 DOI: 10.1002/jssc.202001136] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Revised: 12/18/2020] [Accepted: 12/20/2020] [Indexed: 12/18/2022]
Abstract
We have characterized Atlantis ethylene-bridged hybrid C18 anion-exchange, a mixed-mode reversed-phase/weak anion-exchange stationary phase designed to give greater retention for anions (e.g., ionized acids) compared to conventional reversed-phase materials. The retention and selectivity of this stationary phase were compared to that of three benchmark materials, using a mixture of six polar compounds that includes an acid, two bases, and three neutrals. The compatibility of the ethylene-bridged hybrid C18 anion-exchange material with 100% aqueous mobile phases was also evaluated. We investigated the batch-to-batch reproducibility of the ethylene-bridged hybrid C18 anion-exchange stationary phase for 27 batches across three different particle sizes (1.7, 2.5, and 5 μm) and found it to be comparable to that of one of the most reproducible C18 stationary phases. We also characterized the acid and base stability of the ethylene-bridged hybrid C18 anion-exchange stationary phase and the results show it to be usable over a wide pH range, from 2 to 10. The extended upper pH limit relative to silica-based reversed-phase/weak anion-exchange materials is enabled by the use of ethylene-bridged hybrid organic/inorganic particles. The improved base stability allows Atlantis ethylene-bridged hybrid C18 anion-exchange to be used with a wider range of mobile phase pH values, opening up a greater range of selectivity options.
Collapse
|
30
|
Kadlecová Z, Kalíková K, Ansorge M, Gilar M, Tesařová E. The effect of particle and ligand types on retention and peak shape in liquid chromatography. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105466] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
31
|
Kadlecová Z, Kalíková K, Folprechtová D, Tesařová E, Gilar M. Method for evaluation of ionic interactions in liquid chromatography. J Chromatogr A 2020; 1625:461301. [DOI: 10.1016/j.chroma.2020.461301] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Revised: 05/29/2020] [Accepted: 05/31/2020] [Indexed: 01/17/2023]
|
32
|
De Vos J, Baron GV, Wirth MJ, Terryn H, Kaal ER, Eeltink S. Evaluation of particle and bed integrity of aqueous size-exclusion columns packed with sub-2 µm particles operated at high pressure. J Chromatogr A 2020; 1621:461064. [PMID: 32336499 DOI: 10.1016/j.chroma.2020.461064] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2019] [Revised: 03/19/2020] [Accepted: 03/23/2020] [Indexed: 12/22/2022]
Abstract
The performance of columns packed with 1.7 µm particles for aqueous size-exclusion chromatography was assessed at high-pressure conditions and linked to particle- and column-bed integrity. Decreasing the particle size from 3.5 µm to 1.7 µm increases the resolution due to the improved mass-transfer characteristics, allowing to significantly speed-up analysis without compromising the selectivity. A sub-minute separation of intact proteins was realized on a 4.6 mm i.d × 75 mm long column packed with 1.7 µm SEC particles applying a flow rate of 1.8 mL/min, corresponding to a column pressure of 530 bar. Ultra-high pressure operation (exceeding manufacturer's recommendations) resulted in peak deformation, a shift towards earlier retention times, and an alteration in selectivity. To gain insights in the mechanisms of column deterioration, short 30 mm long columns were operated at UHPLC conditions, maximizing the pressure drop over individual particles. This resulted in the presence of fractured particles situated at the column outlet, as verified by scanning electron micrographs. Mercury-intrusion porosimetry and argon-adsorption measurements did not reveal significant differences in intraparticle volume between particle batches sampled before and after pressure stress testing. As particles at the column outlet fracture (but not collapse) at high pressure operation, a void was formed at the column inlet. The degradation of the separation performance appeared to be the result of a decrease in interparticle pore volume.
Collapse
Affiliation(s)
- Jelle De Vos
- Vrije Universiteit Brussel (VUB), Department of Chemical Engineering, Pleinlaan 2, B-1050, Brussels, Belgium.
| | - Gino V Baron
- Vrije Universiteit Brussel (VUB), Department of Chemical Engineering, Pleinlaan 2, B-1050, Brussels, Belgium
| | - Mary J Wirth
- Purdue University, Department of Chemistry, Purdue, United States
| | - Herman Terryn
- Vrije Universiteit Brussel (VUB), Department of Materials and Chemistry, Research group of Electrochemical and Surface Engineering, Brussels, Belgium
| | - Erwin R Kaal
- DSM Biotechnology Center, part of DSM Food specialties b.v., Delft, Netherlands
| | - Sebastiaan Eeltink
- Vrije Universiteit Brussel (VUB), Department of Chemical Engineering, Pleinlaan 2, B-1050, Brussels, Belgium
| |
Collapse
|
33
|
Hochstrasser J, Svidrytski A, Höltzel A, Priamushko T, Kleitz F, Wang W, Kübel C, Tallarek U. Morphology-transport relationships for SBA-15 and KIT-6 ordered mesoporous silicas. Phys Chem Chem Phys 2020; 22:11314-11326. [PMID: 32406894 DOI: 10.1039/d0cp01861a] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Quantitative morphology-transport relationships are derived for ordered mesoporous silicas through direct numerical simulation of hindered diffusion in realistic geometrical models of the pore space obtained from physical reconstruction by electron tomography. We monitor accessible porosity and effective diffusion coefficients resulting from steric and hydrodynamic interactions between passive tracers and the pore space confinement as a function of λ = dtracer/dmeso (ratio of tracer diameter to mean mesopore diameter) in SBA-15 (dmeso = 9.1 nm) and KIT-6 (dmeso = 10.5 nm) silica samples. For λ = 0, the pointlike tracers reproduce the true diffusive tortuosities. For 0 ≤λ < 0.5, the derived hindrance factor quantifies the extent to which diffusion of finite-size tracers through the materials is hindered compared with free diffusion in the bulk liquid. The hindrance factor connects the transport properties of the ordered silicas to their mesopore space morphologies and enables quantitative comparison with random mesoporous silicas. Key feature of the ordered silicas is a narrow, symmetric mesopore size distribution (∼10% relative standard deviation), which engenders a sharper decline of the accessible-porosity window with increasing λ than observed for random silicas with their wide, asymmetric mesopore size distributions. As support structures, ordered mesoporous silicas should offer benefits for applications where spatial confinement effects and molecular size-selectivity are of prime importance. On the other hand, random mesoporous silicas enable higher diffusivities for λ > 0.3, because the larger pores carry most of the diffusive flux and keep pathways open when smaller pores have closed off.
Collapse
Affiliation(s)
- Janika Hochstrasser
- Department of Chemistry, Philipps-Universität Marburg, Hans-Meerwein-Straße 4, 35032 Marburg, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
34
|
Manetto S, Mazzoccanti G, Ciogli A, Villani C, Gasparrini F. Ultra-high performance separation of basic compounds on reversed-phase columns packed with fully/superficially porous silica and hybrid particles by using ultraviolet transparent hydrophobic cationic additives. J Sep Sci 2020; 43:1653-1662. [PMID: 32043722 DOI: 10.1002/jssc.201901333] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2019] [Revised: 02/06/2020] [Indexed: 12/22/2022]
Abstract
The use of the tetrabutylammonium additive was investigated in the ultra-high performance reversed-phase liquid chromatographic elution of basic molecules of pharmaceutical interest. When added to the mobile phase at low pH, the hydrophobic tetrabutylammonium cation interacts with the octadecyl chains and with the residual silanols, thus imparting a positive charge to the stationary phase, modulating retention and improving peak shape of protonated basic solutes. Two sources of additive were tested: a mixture of tetrabutylammonium hydroxide/trifluoroacetic acid and tetrabutylammonium hydrogen sulfate. Retention and peak shape of 11 basic pharmaceutical compounds were evaluated on commercially available ultra-fast columns packed with octadecyl stationary phases (Ascentis Express C18 2.0 µm, Acquity BEH C18 1.7 µm, Titan C18 1.9 µm). All columns benefit from the use of additive, especially tetrabutylammonium hydrogen sulfate, providing very symmetric peaks with reasonable retention times. Focusing on the probe compounds amitriptyline and sertraline, efficiency and asymmetry values were investigated at increasing retention factor. The trend is very different to that obtained in reversed-phase conditions and the effect lies in the complex molecular interaction mechanisms based on hydrophobic and ion exchange interactions as well as electrostatic repulsion.
Collapse
Affiliation(s)
- Simone Manetto
- Dipartimento di Chimica e Tecnologie del Farmaco, "Sapienza" Università di Roma, Rome, Italy
| | - Giulia Mazzoccanti
- Dipartimento di Chimica e Tecnologie del Farmaco, "Sapienza" Università di Roma, Rome, Italy
| | - Alessia Ciogli
- Dipartimento di Chimica e Tecnologie del Farmaco, "Sapienza" Università di Roma, Rome, Italy
| | - Claudio Villani
- Dipartimento di Chimica e Tecnologie del Farmaco, "Sapienza" Università di Roma, Rome, Italy
| | - Francesco Gasparrini
- Dipartimento di Chimica e Tecnologie del Farmaco, "Sapienza" Università di Roma, Rome, Italy
| |
Collapse
|
35
|
Hettiarachchi K, Hayes M, Desai AJ, Wang J, Ren Z, Greshock TJ. Subminute micro-isolation of pharmaceuticals with ultra-high pressure liquid chromatography. J Pharm Biomed Anal 2019; 176:112794. [PMID: 31437749 DOI: 10.1016/j.jpba.2019.112794] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2019] [Revised: 07/16/2019] [Accepted: 07/28/2019] [Indexed: 11/26/2022]
Abstract
The drive for faster separations while maintaining quality and yield remains an important consideration for enhanced productivity as well as cost reduction for drug discovery laboratories in the pharmaceutical industry. High-throughput experimentation (HTE) and high-throughput screening (HTS) techniques can benefit from rapid and efficient isolation of product at high purity and recovery from microgram-scale crude reaction mixtures. In this study we describe the isolation of small molecule and biomolecule crude mixtures at the microgram-scale (100-2500 μg) in single or library format with methods as fast as 1.0 min and system pressures averaging 10,000 psi with an ultra-high pressure liquid chromatography (UHPLC) setup. UHPLC technology provides several advantages for rapid (<1.0 min) separations with small-particle (1.8-3.5 μm) size 4.6 × 50 mm C18 columns such as minimal extra column and delay volume, fast detector response time, and higher linear velocities for improved speed and resolution. We typically see a 5-10 fold improvement in purification time and overall sample processing time with low fraction volumes and same-day drying when compared with traditional semi-preparative techniques. There is a significant 50-fold reduction in solvent usage per run, resulting in a much lower cost of solvent and waste handling. Fluidic pathways have been optimized for collection into tared high-density 96 or 384 well 2D barcoded storage tubes in a microtiter plate (MTP) layout. Coupling the system to robotics has enabled us to implement a fully integrated automation platform with additional capabilities for small-scale purification at high speed and reduced cost of materials. The resulting arrays of small-quantity, high-purity compounds enable synthetic route scouting for HTE and HTS for biological target validation.
Collapse
Affiliation(s)
- Kanaka Hettiarachchi
- Discovery Chemistry, Merck & Co., Inc., 213. E. Grand Ave., South San Francisco, CA 94080, USA.
| | - Michael Hayes
- Discovery Chemistry, Merck & Co., Inc., 213. E. Grand Ave., South San Francisco, CA 94080, USA
| | - Aditya J Desai
- Pharmacology, Merck & Co., Inc., 213. E. Grand Ave., South San Francisco, CA 94080, USA
| | - Jun Wang
- Discovery Chemistry, Merck & Co., Inc., 213. E. Grand Ave., South San Francisco, CA 94080, USA
| | - Zhao Ren
- Pharmacology, Merck & Co., Inc., 213. E. Grand Ave., South San Francisco, CA 94080, USA
| | - Thomas J Greshock
- Discovery Chemistry, Merck & Co., Inc., 213. E. Grand Ave., South San Francisco, CA 94080, USA
| |
Collapse
|
36
|
Aristizabal-Henao JJ, Fernandes MF, Duncan RE, Stark KD. Development of a Rapid Ultra High-Performance Liquid Chromatography/Tandem Mass Spectrometry Method for the Analysis of sn-1 and sn-2 Lysophosphatidic Acid Regioisomers in Mouse Plasma. Lipids 2019; 54:479-486. [PMID: 31236951 DOI: 10.1002/lipd.12172] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2019] [Revised: 05/27/2019] [Accepted: 05/28/2019] [Indexed: 12/11/2022]
Abstract
Lysophosphatidic acids (lysoPtdOH) are involved in several physiological processes including cell proliferation, inflammation, and glucose metabolism. However, measuring lysoPtdOH is challenging due to inadequate extraction techniques, poor chromatographic resolution, or the inability to discriminate between sn-1 and sn-2 regioisomers. In the present work, we developed a high-throughput (10 min run times) ultra-high-performance liquid chromatography-tandem mass spectrometry method capable of discriminating lysoPtdOH species by their fatty acyl composition and sn-localization on glycerol backbones. We quantitated sn-1/sn-2 regioisomeric pairs of lysoPtdOH with 16:0, 18:0, 18:1, 18:2, 20:4, and 22:6 fatty acyl chains using 50 μL of mouse plasma. The method presented here can be expanded to profile more lysoPtdOH species, and has the potential to be used in clinical settings to quickly screen lysoPtdOH profiles. Finally, the ability to discriminate between sn-1 and sn-2 isomers can provide insights regarding the metabolic origins and fates of specific lysoPtdOH molecules.
Collapse
Affiliation(s)
- Juan J Aristizabal-Henao
- Department of Kinesiology, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| | - Maria F Fernandes
- Department of Kinesiology, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| | - Robin E Duncan
- Department of Kinesiology, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| | - Ken D Stark
- Department of Kinesiology, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| |
Collapse
|
37
|
Liang Y, Zhang L, Zhang Y. Well-Defined Materials for High-Performance Chromatographic Separation. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2019; 12:451-473. [PMID: 30939031 DOI: 10.1146/annurev-anchem-061318-114854] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Chromatographic separation has been widely applied in various fields, such as chemical engineering, precision medicine, energy, and biology. Because chromatographic separation is based on differential partitioning between the mobile phase and stationary phase and affected by band dispersion and mass transfer resistance from these two phases, the materials used as the stationary phase play a decisive role in separation performance. In this review, we discuss the design of separation materials to achieve the separation with high efficiency and high resolution and highlight the well-defined materials with uniform pore structure and unique properties. The achievements, recent developments, challenges, and future trends of such materials are discussed. Furthermore, the surface functionalization of separation ma-terials for further improvement of separation performance is reviewed. Finally, future research directions and the challenges of chromatographic separation are presented.
Collapse
Affiliation(s)
- Yu Liang
- CAS Key Lab of Separation Sciences for Analytical Chemistry, National Chromatographic Research and Analysis Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China;
| | - Lihua Zhang
- CAS Key Lab of Separation Sciences for Analytical Chemistry, National Chromatographic Research and Analysis Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China;
| | - Yukui Zhang
- CAS Key Lab of Separation Sciences for Analytical Chemistry, National Chromatographic Research and Analysis Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China;
| |
Collapse
|
38
|
Kozlov O, Kadlecová Z, Gilar M, Gondová T, Kalíková K, Tesařová E. Systematic evaluation of selected supercritical fluid chromatography diol‐ and diethylamine‐based columns for application in hydrophilic interaction liquid chromatography. SEPARATION SCIENCE PLUS 2019. [DOI: 10.1002/sscp.201900023] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Affiliation(s)
- Oleksandr Kozlov
- Department of Analytical ChemistryFaculty of ScienceP. J. Šafárik University Košice Slovak Republic
| | - Zuzana Kadlecová
- Department of Physical and Macromolecular ChemistryFaculty of ScienceCharles University Prague Czech Republic
| | | | - Taťána Gondová
- Department of Analytical ChemistryFaculty of ScienceP. J. Šafárik University Košice Slovak Republic
| | - Květa Kalíková
- Department of Physical and Macromolecular ChemistryFaculty of ScienceCharles University Prague Czech Republic
| | - Eva Tesařová
- Department of Physical and Macromolecular ChemistryFaculty of ScienceCharles University Prague Czech Republic
| |
Collapse
|
39
|
Fan L, Chen XD, Mercadé-Prieto R. On the nature of the optimum cleaning concentration for dairy fouling: High NaOH concentrations inhibit the cleavage of non-covalent interactions in whey protein aggregates. Lebensm Wiss Technol 2019. [DOI: 10.1016/j.lwt.2018.11.050] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
40
|
Žuvela P, Skoczylas M, Jay Liu J, Ba Czek T, Kaliszan R, Wong MW, Buszewski B, Héberger K. Column Characterization and Selection Systems in Reversed-Phase High-Performance Liquid Chromatography. Chem Rev 2019; 119:3674-3729. [PMID: 30604951 DOI: 10.1021/acs.chemrev.8b00246] [Citation(s) in RCA: 148] [Impact Index Per Article: 29.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Reversed-phase high-performance liquid chromatography (RP-HPLC) is the most popular chromatographic mode, accounting for more than 90% of all separations. HPLC itself owes its immense popularity to it being relatively simple and inexpensive, with the equipment being reliable and easy to operate. Due to extensive automation, it can be run virtually unattended with multiple samples at various separation conditions, even by relatively low-skilled personnel. Currently, there are >600 RP-HPLC columns available to end users for purchase, some of which exhibit very large differences in selectivity and production quality. Often, two similar RP-HPLC columns are not equally suitable for the requisite separation, and to date, there is no universal RP-HPLC column covering a variety of analytes. This forces analytical laboratories to keep a multitude of diverse columns. Therefore, column selection is a crucial segment of RP-HPLC method development, especially since sample complexity is constantly increasing. Rationally choosing an appropriate column is complicated. In addition to the differences in the primary intermolecular interactions with analytes of the dispersive (London) type, individual columns can also exhibit a unique character owing to specific polar, hydrogen bond, and electron pair donor-acceptor interactions. They can also vary depending on the type of packing, amount and type of residual silanols, "end-capping", bonding density of ligands, and pore size, among others. Consequently, the chromatographic performance of RP-HPLC systems is often considerably altered depending on the selected column. Although a wide spectrum of knowledge is available on this important subject, there is still a lack of a comprehensive review for an objective comparison and/or selection of chromatographic columns. We aim for this review to be a comprehensive, authoritative, critical, and easily readable monograph of the most relevant publications regarding column selection and characterization in RP-HPLC covering the past four decades. Future perspectives, which involve the integration of state-of-the-art molecular simulations (molecular dynamics or Monte Carlo) with minimal experiments, aimed at nearly "experiment-free" column selection methodology, are proposed.
Collapse
Affiliation(s)
- Petar Žuvela
- Department of Chemistry , National University of Singapore , Singapore 117543 , Singapore
| | - Magdalena Skoczylas
- Department of Environmental Chemistry and Bioanalytics, Center for Modern Interdisciplinary Technologies , Nicolaus Copernicus University , Wileńska 4 , 87-100 Toruń , Poland
| | - J Jay Liu
- Department of Chemical Engineering , Pukyong National University , 365 Sinseon-ro , Nam-gu, 48-513 Busan , Korea
| | | | | | - Ming Wah Wong
- Department of Chemistry , National University of Singapore , Singapore 117543 , Singapore
| | - Bogusław Buszewski
- Department of Environmental Chemistry and Bioanalytics, Center for Modern Interdisciplinary Technologies , Nicolaus Copernicus University , Wileńska 4 , 87-100 Toruń , Poland
| | | |
Collapse
|
41
|
Li J, Xu L, Shi ZG. Waxberry-like hierarchically porous ethyl-bridged hybrid silica microsphere: A substrate for enzyme catalysis and high-performance liquid chromatography. J Chromatogr A 2018; 1587:79-87. [PMID: 30527847 DOI: 10.1016/j.chroma.2018.11.073] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2018] [Revised: 11/22/2018] [Accepted: 11/28/2018] [Indexed: 10/27/2022]
Abstract
In this study, the ethyl-bridged hybrid silica microsphere with hierarchically meso-macroporous structure was initially synthesized through a method combining dispersion polymerization with sol-gel transition and phase separation. The flow-through macropores rendered the microsphere a rough surface like a waxberry, and thus the material was named as waxberry-like ethyl-bridged hybrid silica sphere (WEHS). WEHS was characteristic of appropriate alkali-stability, which was highly difficult for the pure silica. Additionally, WEHS possessed hierarchical meso- and macropores, which added additional value for faster mass transfer than the conventional fully porous silica materials. Taking the advantages of WEHS, it was successfully applied as the substrate to immobilize lipase; the prepared immobilized lipase exhibited high catalytic activity and favorable reusability under alkaline conditions, which was significant in pitch control of neutral-alkaline papermaking industry. Moreover, as the high-performance liquid chromatographic stationary phase matrix, WEHS made the separation under alkaline mobile phase into a reality for the silica-based materials. Besides, an ultra-fast and efficient separation in minutes was achieved with lower consumption of solvents and saving analytical time, which is highly desired in modern analysis. In general, WEHS was a novel and promising candidate in the myriads of silica-based materials.
Collapse
Affiliation(s)
- Jing Li
- Department of Chemistry, Wuhan University, Wuhan, 430072, China; Tongji School of Pharmacy, Huazhong University of Science and Technology, Wuhan, 430030, China
| | - Li Xu
- Tongji School of Pharmacy, Huazhong University of Science and Technology, Wuhan, 430030, China
| | - Zhi-Guo Shi
- Department of Chemistry, Wuhan University, Wuhan, 430072, China.
| |
Collapse
|
42
|
Huang TY, Chi LM, Chien KY. Size-exclusion chromatography using reverse-phase columns for protein separation. J Chromatogr A 2018; 1571:201-212. [DOI: 10.1016/j.chroma.2018.08.020] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2018] [Revised: 08/03/2018] [Accepted: 08/09/2018] [Indexed: 01/02/2023]
|
43
|
Use of Cyclodextrin as a Novel Agent in the SEC-HPLC Mobile Phase to Mitigate the Interactions of Proteins or Peptide or their Impurities with the Residual Silanols of Commercial SEC-HPLC Columns with Improved Separation and Resolution. Pharm Res 2018; 35:168. [DOI: 10.1007/s11095-018-2446-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2018] [Accepted: 06/14/2018] [Indexed: 10/28/2022]
|
44
|
Vieira AT, Assunção RMN, Faria AM. Stationary phase based on cellulose dodecanoate physically immobilized on silica particles for high-performance liquid chromatography. J Chromatogr A 2018; 1572:72-81. [PMID: 30153982 DOI: 10.1016/j.chroma.2018.08.048] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2018] [Revised: 08/19/2018] [Accepted: 08/21/2018] [Indexed: 10/28/2022]
Abstract
The chemical agent free preparation of a stationary phase using a natural macromolecule was the focus of this paper. Thermal immobilization of cellulose dodecanoate on silica particles was used for the preparation of a stationary phase without the use of chemical reagents. Cellulose modification was performed to produce a hydrophobic macromolecule with solubility in common organic solvents. The new stationary phase was characterized morphologically and physico-chemically, presenting as spherical particles immobilized with a thin cellulose dodecanoate layer. The degree of substitution of cellulose dodecanoate was 1.7, which resulted in a separation mechanism in reversed phase mode, but with lower hydrophobicity and higher steric selectivity, which are properties from cellulose. These characteristics resulted in a stationary phase with intrinsic selectivity that was able to separate mixtures of polar drugs, homologs of an anionic surfactant and omeprazole isomers, which are not well resolved in typical C18 phases. Considering that cellulose is a natural polymer and the preparation method of stationary phase involves only physical processes of silica modification, the final material presents as a stationary phase with specific retention properties coming from both dodecanoate and cellulose.
Collapse
Affiliation(s)
- Andressa T Vieira
- Instituto de Ciências Exatas e Naturais do Pontal, Universidade Federal de Uberlândia, 38304-402 Ituiutaba, MG, Brazil
| | - Rosana M N Assunção
- Instituto de Ciências Exatas e Naturais do Pontal, Universidade Federal de Uberlândia, 38304-402 Ituiutaba, MG, Brazil
| | - Anizio M Faria
- Instituto de Ciências Exatas e Naturais do Pontal, Universidade Federal de Uberlândia, 38304-402 Ituiutaba, MG, Brazil.
| |
Collapse
|
45
|
Wu C, Liang Y, Zhu X, Zhao Q, Fang F, Zhang X, Liang Z, Zhang L, Zhang Y. Macro-mesoporous organosilica monoliths with bridged-ethylene and terminal-vinyl: High-density click functionalization for chromatographic separation. Anal Chim Acta 2018; 1038:198-205. [PMID: 30278903 DOI: 10.1016/j.aca.2018.07.004] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2018] [Revised: 06/20/2018] [Accepted: 07/02/2018] [Indexed: 11/24/2022]
Abstract
A novel kind of macro-mesoporous organosilica monolith, with not only bridged-ethylene groups incorporated into the skeleton but also terminal-vinyl groups protruded from the pore-wall, was prepared so that high-loaded double bonds were achieved. Via highly efficient "thiol-ene" click reaction of such high-loaded double bonds, the surface coverage of C18 groups on monolith could be 5.54 μmol m-2, significantly larger than that of the reported separation materials, beneficial to improvement of separation resolution, especially for peptide separation. The separation performance was evaluated using alkylbenzenes and standard peptides. Furthermore, the tryptic digests of complex sample was successfully analyzed. Because of high separation resolution of our prepared hybrid monolith, the peak capacity for 6-h gradient was achieved as 482. Coupling to LTQ Orbitrap Velos Mass Spectrometry, 22523 tryptic peptides from 4423 proteins were identified from the HeLa cells, more than that using the other long-gradient separation by the same system reported, showing great promising of such monolith for large-scale in-depth proteomic analysis.
Collapse
Affiliation(s)
- Ci Wu
- CAS Key Lab of Separation Sciences for Analytical Chemistry, National Chromatographic Research and Analysis Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, China; Inspection and Quarantine Technical Center of Dalian Entry-Exit Inspection and Quarantine Bureau, Dalian, 116100, China
| | - Yu Liang
- CAS Key Lab of Separation Sciences for Analytical Chemistry, National Chromatographic Research and Analysis Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, China
| | - Xudong Zhu
- CAS Key Lab of Separation Sciences for Analytical Chemistry, National Chromatographic Research and Analysis Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, China
| | - Qun Zhao
- CAS Key Lab of Separation Sciences for Analytical Chemistry, National Chromatographic Research and Analysis Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, China
| | - Fei Fang
- CAS Key Lab of Separation Sciences for Analytical Chemistry, National Chromatographic Research and Analysis Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, China
| | - Xiaodan Zhang
- CAS Key Lab of Separation Sciences for Analytical Chemistry, National Chromatographic Research and Analysis Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, China
| | - Zhen Liang
- CAS Key Lab of Separation Sciences for Analytical Chemistry, National Chromatographic Research and Analysis Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, China
| | - Lihua Zhang
- CAS Key Lab of Separation Sciences for Analytical Chemistry, National Chromatographic Research and Analysis Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, China.
| | - Yukui Zhang
- CAS Key Lab of Separation Sciences for Analytical Chemistry, National Chromatographic Research and Analysis Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, China
| |
Collapse
|
46
|
Buszewska-Forajta M, Markuszewski MJ, Kaliszan R. Free silanols and ionic liquids as their suppressors in liquid chromatography. J Chromatogr A 2018; 1559:17-43. [DOI: 10.1016/j.chroma.2018.04.002] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2017] [Revised: 03/28/2018] [Accepted: 04/01/2018] [Indexed: 12/21/2022]
|
47
|
Chu Z, Zhang L, Zhang W. Preparation and evaluation of maltose modified polymer-silica composite based on cross-linked poly glycidyl methacrylate as high performance liquid chromatography stationary phase. Anal Chim Acta 2018; 1036:179-186. [PMID: 30253830 DOI: 10.1016/j.aca.2018.06.027] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2018] [Revised: 06/07/2018] [Accepted: 06/09/2018] [Indexed: 12/13/2022]
Abstract
A new maltose modified polymer-silica composite was fabricated and applied as high performance liquid chromatography (HPLC) stationary phase. The cross-linked poly glycidyl methacrylate (pGMA) layer was chemically bonded to the outer surface as well as pore inner surface of silica beads via in-situ polymerization, and then maltose was modified onto the polymer layer via a [3 + 2] "click" reaction. The porous spherical silica (4 μm diameter) with 300 Å pore size was selected as the matrix so that the 3.25 nm-thick polymer layer fabricated on the pore inner surface would not affect its permeability. The typical 'U-shape' retention curves indicated a mixed-mode retention mechanism of the as-synthesized stationary phase. Both polar and non-polar analytes could be well separated on the stationary phase with column efficiency reaching 123809 plates/m for guanosine in hydrophilic interaction liquid chromatography (HILIC) mode and 46808 plates/m for fluorene in reversed-phase liquid chromatography (RPLC) mode, respectively. Nucleotides and their bases were baseline separated with good peak shape without any buffer salt in mobile phase, suggesting the effective shielding of the silanol groups. The packing material also showed excellent chromatographic repeatability with intraday RSDs of the retention time of five nucleosides less than 0.048% (n = 3) and interday RSDs less than 0.33% (n = 7) and great pH stability (from 1.5 to 10.2). Finally, the stationary phase was applied to the separation of ginseng extract.
Collapse
Affiliation(s)
- Zhanying Chu
- Shanghai Key Laboratory of Functional Materials Chemistry, School of Chemistry & Molecular Engineering, East China University of Science and Technology, Shanghai, 200237, PR China
| | - Lingyi Zhang
- Shanghai Key Laboratory of Functional Materials Chemistry, School of Chemistry & Molecular Engineering, East China University of Science and Technology, Shanghai, 200237, PR China.
| | - Weibing Zhang
- Shanghai Key Laboratory of Functional Materials Chemistry, School of Chemistry & Molecular Engineering, East China University of Science and Technology, Shanghai, 200237, PR China.
| |
Collapse
|
48
|
Huo Z, Wan Q, Chen L. Synthesis and evaluation of porous polymethylsilsesquioxane microspheres as low silanol activity chromatographic stationary phase for basic compound separation. J Chromatogr A 2018; 1553:90-100. [DOI: 10.1016/j.chroma.2018.04.024] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2018] [Revised: 04/05/2018] [Accepted: 04/10/2018] [Indexed: 11/29/2022]
|
49
|
Tassi M, De Vos J, Chatterjee S, Sobott F, Bones J, Eeltink S. Advances in native high-performance liquid chromatography and intact mass spectrometry for the characterization of biopharmaceutical products. J Sep Sci 2017; 41:125-144. [DOI: 10.1002/jssc.201700988] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2017] [Revised: 09/29/2017] [Accepted: 09/29/2017] [Indexed: 12/21/2022]
Affiliation(s)
- Marco Tassi
- Department of Chemical Engineering; Vrije Universiteit Brussel (VUB); Brussels Belgium
| | - Jelle De Vos
- Department of Chemical Engineering; Vrije Universiteit Brussel (VUB); Brussels Belgium
| | - Sneha Chatterjee
- Biomolecular & Analytical Mass Spectrometry; Antwerp University; Antwerp Belgium
| | - Frank Sobott
- Biomolecular & Analytical Mass Spectrometry; Antwerp University; Antwerp Belgium
- Astbury Centre for Structural Molecular Biology; University of Leeds; Leeds UK
- School of Molecular and Cellular Biology; University of Leeds; Leeds UK
| | - Jonathan Bones
- The National Institute for Bioprocessing Research and Training (NIBRT); Dublin Ireland
| | - Sebastiaan Eeltink
- Department of Chemical Engineering; Vrije Universiteit Brussel (VUB); Brussels Belgium
| |
Collapse
|
50
|
Peng SH, Yue XY, Wang YL, Wei Q, Cui SP, Nie ZR, Li QY. C18-Free Organic–Inorganic Hybrid Silica Particles Derived from Sole Silsesquioxane for Reversed-Phase HPLC. Chromatographia 2017. [DOI: 10.1007/s10337-017-3428-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|