1
|
Chen Y, Brook MA. Starch-Directed Synthesis of Worm-Shaped Silica Microtubes. MATERIALS (BASEL, SWITZERLAND) 2023; 16:2831. [PMID: 37049125 PMCID: PMC10096145 DOI: 10.3390/ma16072831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/26/2023] [Revised: 03/28/2023] [Accepted: 03/31/2023] [Indexed: 06/19/2023]
Abstract
Many strategies have been adopted to prepare silica materials with highly controlled structures, typically using sol-gel chemistry. Frequently, the alkoxysilanes used in sol-gel chemistry are based on monoalcohols, e.g., Si(OEt)4. The structural control over silica synthesis achieved by these precursors is highly sensitive to pH and solvency. Alkoxysilanes derived from the sugar alcohol glycerol (diglycerylsilane) react more slowly and with much less sensitivity to pH. We report that, in the presence of cooled aqueous starch solutions, glyceroxysilanes undergo transesterification with the sugars on starch, leading to (hollow) microtubules resembling worms of about 400 nm in diameter. The tubes arise from the pre-assembly of starch bundles, which occurs only well below room temperature. It is straightforward to treat the first-formed starch/silica composite with the enzyme amylase to, in a programmed fashion, increasingly expose porosity, including the worm morphology, while washing away untethered silica and digested starch to leave an open, highly porous materials. Sintering at 600 °C completely removes the starch silane moieties.
Collapse
|
2
|
Covey T. Where have all the ions gone, long time passing? Tandem quadrupole mass spectrometers with atmospheric pressure ionization sensitivity gains since the mid-1970s. A perspective. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2022:e9354. [PMID: 35830299 DOI: 10.1002/rcm.9354] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Revised: 05/09/2022] [Accepted: 07/07/2022] [Indexed: 06/15/2023]
Abstract
The gains in sensitivity since 1975 for quadrupole mass spectrometers equipped with atmospheric pressure ionization (API), and in particular triple quadrupole mass spectrometers (QqQs) since 1981, have been driven by the needs of the environmental, biomedical, agricultural, and other scientific research, industrial, regulatory, legal, and sporting communities to continually achieve lower limits of quantitation and identification. QqQs have realized a one-million-fold improvement in sensitivity attempting to address these needs over the past two score years. It is the purpose of this article to describe how that came about, not through an exhaustive review of the literature, but rather by describing what general approaches were used across the industry to improve sensitivity and provide some examples to illustrate its evolution. The majority of the gains came from the ion source and its interface to the vacuum system. "Sampling efficiency" is a measurement of the losses in this area so will be a focus of this review. The discovery of the phenomenon of collisional focusing was key to improving sampling efficiency because it enabled designs that increased the ion-containing gas loads from the ion source, using staged differential pumping backed by increasingly larger pumps, and prevented the scattering losses of ions in the resulting gas expansion inside vacuum. Likewise, systems with smaller pumps and lower ion-containing gas loads could be designed with size and cost reduction in mind while maintaining reasonable sampling efficiencies. As a consequence, advancements in the designs of both larger and smaller turbomolecular vacuum pumps were accelerated by pump manufacturers to accommodate the explosive growth in the use of API-QqQ and API-ion trap mass spectrometers that occurred in the 1990s and continued into the new millennium. Sampling efficiency was further improved by increasing the ion yield from electrospray by increasing the rate of droplet desolvation. An estimate of the practical limit to further sensitivity improvements beyond what has been achieved to date is provided to shed light on what to expect in the future. Lastly, the implications and unforeseen consequences of the sensitivity gains are considered with a particular focus on how they have enabled a dramatic increase in daily sample throughput on triple quadrupole and other types of mass spectrometers.
Collapse
|
3
|
Poddar S, Sharmeen S, Hage DS. Affinity monolith chromatography: A review of general principles and recent developments. Electrophoresis 2021; 42:2577-2598. [PMID: 34293192 PMCID: PMC9536602 DOI: 10.1002/elps.202100163] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 07/07/2021] [Accepted: 07/18/2021] [Indexed: 12/28/2022]
Abstract
Affinity monolith chromatography (AMC) is a liquid chromatographic technique that utilizes a monolithic support with a biological ligand or related binding agent to isolate, enrich, or detect a target analyte in a complex matrix. The target-specific interaction exhibited by the binding agents makes AMC attractive for the separation or detection of a wide range of compounds. This article will review the basic principles of AMC and recent developments in this field. The supports used in AMC will be discussed, including organic, inorganic, hybrid, carbohydrate, and cryogel monoliths. Schemes for attaching binding agents to these monoliths will be examined as well, such as covalent immobilization, biospecific adsorption, entrapment, molecular imprinting, and coordination methods. An overview will then be given of binding agents that have recently been used in AMC, along with their applications. These applications will include bioaffinity chromatography, immunoaffinity chromatography, immobilized metal-ion affinity chromatography, and dye-ligand or biomimetic affinity chromatography. The use of AMC in chiral separations and biointeraction studies will also be discussed.
Collapse
Affiliation(s)
- Saumen Poddar
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, 68588, USA
| | - Sadia Sharmeen
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, 68588, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, 68588, USA
| |
Collapse
|
4
|
Some Applications of Liquid Chromatography-Mass Spectrometry in the Biomedical Field. ACTA ACUST UNITED AC 2018. [DOI: 10.1016/bs.coac.2017.09.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/12/2023]
|
5
|
Aduri NG, Ernst HA, Prabhala BK, Bhatt S, Boesen T, Gajhede M, Mirza O. Human proton coupled folic acid transporter is a monodisperse oligomer in the lauryl maltose neopentyl glycol solubilized state. Biochem Biophys Res Commun 2017; 495:1738-1743. [PMID: 29208467 DOI: 10.1016/j.bbrc.2017.12.008] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2017] [Accepted: 12/01/2017] [Indexed: 01/23/2023]
Abstract
The human proton coupled folic acid transporter PCFT is the major import route for dietary folates. Mutations in the gene encoding PCFT cause hereditary folic acid malabsorption, which manifests itself by compromised folate absorption from the intestine and also in impaired folate transport into the central nervous system. Since its recent discovery, PCFT has been the subject of numerous biochemical studies aiming at understanding its structure and mechanism. One major focus has been its oligomeric state, with some reports supporting oligomers and others a monomer. Here, we report the overexpression and purification of recombinant PCFT. Following detergent screening, n-Dodecyl β-D-maltoside (DDM) and lauryl maltose neopentyl glycol (LMNG) were chosen for further work as they exhibited the most optimal solubilization. We found that purified detergent solubilized PCFT was able to bind folic acid, thus indicating a functionally active protein. Size exclusion chromatography showed that PCFT in DDM was polydisperse; the LMNG preparation was clearly monodisperse but with shorter retention time than the major DDM peak. To assess the oligomeric state negative stain electron microscopy was performed which showed a particle with the size of a PCFT dimer.
Collapse
Affiliation(s)
- Nanda G Aduri
- Department of Drug Design and Pharmacology, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Heidi A Ernst
- Department of Drug Design and Pharmacology, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Bala K Prabhala
- Department of Drug Design and Pharmacology, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Shweta Bhatt
- Department of Drug Design and Pharmacology, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Thomas Boesen
- Interdisciplinary Nanoscience Center, Aarhus University, Gustav Wieds Vej 14, 8000 Aarhus, Denmark
| | - Michael Gajhede
- Department of Drug Design and Pharmacology, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Osman Mirza
- Department of Drug Design and Pharmacology, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.
| |
Collapse
|
6
|
Li Z, Hage DS. Analysis of stereoselective drug interactions with serum proteins by high-performance affinity chromatography: A historical perspective. J Pharm Biomed Anal 2017; 144:12-24. [PMID: 28094095 PMCID: PMC5505820 DOI: 10.1016/j.jpba.2017.01.026] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2016] [Revised: 01/06/2017] [Accepted: 01/10/2017] [Indexed: 01/09/2023]
Abstract
The interactions of drugs with serum proteins are often stereoselective and can affect the distribution, activity, toxicity and rate of excretion of these drugs in the body. A number of approaches based on affinity chromatography, and particularly high-performance affinity chromatography (HPAC), have been used as tools to study these interactions. This review describes the general principles of affinity chromatography and HPAC as related to their use in drug binding studies. The types of serum agents that have been examined with these methods are also discussed, including human serum albumin, α1-acid glycoprotein, and lipoproteins. This is followed by a description of the various formats based on affinity chromatography and HPAC that have been used to investigate drug interactions with serum proteins and the historical development for each of these formats. Specific techniques that are discussed include zonal elution, frontal analysis, and kinetic methods such as those that make use of band-broadening measurements, peak decay analysis, or ultrafast affinity extraction.
Collapse
Affiliation(s)
- Zhao Li
- Department of Chemistry, University of Nebraska, Lincoln, NE, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska, Lincoln, NE, USA.
| |
Collapse
|
7
|
Hage DS. Analysis of Biological Interactions by Affinity Chromatography: Clinical and Pharmaceutical Applications. Clin Chem 2017; 63:1083-1093. [PMID: 28396561 DOI: 10.1373/clinchem.2016.262253] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2016] [Accepted: 12/02/2016] [Indexed: 12/27/2022]
Abstract
BACKGROUND The interactions between biochemical and chemical agents in the body are important in many clinical processes. Affinity chromatography and high-performance affinity chromatography (HPAC), in which a column contains an immobilized biologically related binding agent, are 2 methods that can be used to study these interactions. CONTENT This review presents various approaches that can be used in affinity chromatography and HPAC to characterize the strength or rate of a biological interaction, the number and types of sites that are involved in this process, and the interactions between multiple solutes for the same binding agent. A number of applications for these methods are examined, with an emphasis on recent developments and high-performance affinity methods. These applications include the use of these techniques for fundamental studies of biological interactions, high-throughput screening of drugs, work with modified proteins, tools for personalized medicine, and studies of drug-drug competition for a common binding agent. SUMMARY The wide range of formats and detection methods that can be used with affinity chromatography and HPAC for examining biological interactions makes these tools attractive for various clinical and pharmaceutical applications. Future directions in the development of small-scale columns and the coupling of these methods with other techniques, such as mass spectrometry or other separation methods, should continue to increase the flexibility and ease with which these approaches can be used in work involving clinical or pharmaceutical samples.
Collapse
Affiliation(s)
- David S Hage
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE.
| |
Collapse
|
8
|
Matsuda R, Jobe D, Beyersdorf J, Hage DS. Analysis of drug-protein binding using on-line immunoextraction and high-performance affinity microcolumns: Studies with normal and glycated human serum albumin. J Chromatogr A 2015; 1416:112-20. [PMID: 26381571 PMCID: PMC4587353 DOI: 10.1016/j.chroma.2015.09.023] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2015] [Revised: 09/02/2015] [Accepted: 09/05/2015] [Indexed: 02/03/2023]
Abstract
A method combining on-line immunoextraction microcolumns with high-performance affinity chromatography (HPAC) was developed and tested for use in examining drug-protein interactions with normal or modified proteins. Normal human serum albumin (HSA) and glycated HSA were used as model proteins for this work. High-performance immunoextraction microcolumns with sizes of 1.0-2.0 cm × 2.1mm i.d. and containing anti-HSA polyclonal antibodies were developed and tested for their ability to bind normal HSA or glycated HSA. These microcolumns were able to extract up to 82-93% for either type of protein at 0.05-0.10 mL/min and had a binding capacity of 0.34-0.42 nmol HSA for a 1.0 cm × 2.1mm i.d. microcolumn. The immunoextraction microcolumns and their adsorbed proteins were tested for use in various approaches for drug binding studies. Frontal analysis was used with the adsorbed HSA/glycated HSA to measure the overall affinities of these proteins for the drugs warfarin and gliclazide, giving comparable values to those obtained previously using similar protein preparations that had been covalently immobilized within HPAC columns. Zonal elution competition studies with gliclazide were next performed to examine the specific interactions of this drug at Sudlow sites I and II of the adsorbed proteins. These results were also comparable to those noted in prior work with covalently immobilized samples of normal HSA or glycated HSA. These experiments indicated that drug-protein binding studies can be carried out by using on-line immunoextraction microcolumns with HPAC. The same method could be used in the future with clinical samples and other drugs or proteins of interest in pharmaceutical studies or biomedical research.
Collapse
Affiliation(s)
- Ryan Matsuda
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - Donald Jobe
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - Jared Beyersdorf
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA.
| |
Collapse
|
9
|
Zheng X, Li Z, Beeram S, Podariu M, Matsuda R, Pfaunmiller EL, White CJ, Carter N, Hage DS. Analysis of biomolecular interactions using affinity microcolumns: a review. J Chromatogr B Analyt Technol Biomed Life Sci 2014; 968:49-63. [PMID: 24572459 PMCID: PMC4112177 DOI: 10.1016/j.jchromb.2014.01.026] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2013] [Revised: 01/16/2014] [Accepted: 01/19/2014] [Indexed: 12/15/2022]
Abstract
Affinity chromatography has become an important tool for characterizing biomolecular interactions. The use of affinity microcolumns, which contain immobilized binding agents and have volumes in the mid-to-low microliter range, has received particular attention in recent years. Potential advantages of affinity microcolumns include the many analysis and detection formats that can be used with these columns, as well as the need for only small amounts of supports and immobilized binding agents. This review examines how affinity microcolumns have been used to examine biomolecular interactions. Both capillary-based microcolumns and short microcolumns are considered. The use of affinity microcolumns with zonal elution and frontal analysis methods are discussed. The techniques of peak decay analysis, ultrafast affinity extraction, split-peak analysis, and band-broadening studies are also explored. The principles of these methods are examined and various applications are provided to illustrate the use of these methods with affinity microcolumns. It is shown how these techniques can be utilized to provide information on the binding strength and kinetics of an interaction, as well as on the number and types of binding sites. It is further demonstrated how information on competition or displacement effects can be obtained by these methods.
Collapse
Affiliation(s)
- Xiwei Zheng
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - Zhao Li
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - Sandya Beeram
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - Maria Podariu
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - Ryan Matsuda
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - Erika L Pfaunmiller
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - Christopher J White
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - NaTasha Carter
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA.
| |
Collapse
|
10
|
Forsberg EM, Sicard C, Brennan JD. Solid-phase biological assays for drug discovery. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2014; 7:337-359. [PMID: 25000820 DOI: 10.1146/annurev-anchem-071213-020241] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
In the past 30 years, there has been a significant growth in the use of solid-phase assays in the area of drug discovery, with a range of new assays being used for both soluble and membrane-bound targets. In this review, we provide some basic background to typical drug targets and immobilization protocols used in solid-phase biological assays (SPBAs) for drug discovery, with emphasis on particularly labile biomolecular targets such as kinases and membrane-bound receptors, and highlight some of the more recent approaches for producing protein microarrays, bioaffinity columns, and other devices that are central to small molecule screening by SPBA. We then discuss key applications of such assays to identify drug leads, with an emphasis on the screening of mixtures. We conclude by highlighting specific advantages and potential disadvantages of SPBAs, particularly as they relate to particular assay formats.
Collapse
Affiliation(s)
- Erica M Forsberg
- Biointerfaces Institute, McMaster University, Hamilton, Ontario L8S 4L8, Canada;
| | | | | |
Collapse
|
11
|
Ng E, Schriemer DC. Emerging challenges in ligand discovery: new opportunities for chromatographic assay. Expert Rev Proteomics 2014; 2:891-900. [PMID: 16307518 DOI: 10.1586/14789450.2.6.891] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Ligand discovery initiatives are facing interesting challenges as ever-increasing numbers of proteins are entering screening programs. As an answer to steady pressure to improve performance in drug discovery, ligand discovery can expect to play an expanded role in generating small molecules as probes to help uncover the function of novel proteins. Chromatographic assay formats can offer new entry points into standard interaction characterization (binding and rate constants) as well as powerful, scaleable methods for compound screening. This review presents recent advancements in chromatographic assay technology, with a particular focus on frontal affinity chromatography as a platform technology for interaction analysis.
Collapse
Affiliation(s)
- Ella Ng
- University of Calgary, SAMS Centre for Proteomics, Department of Biochemistry & Molecular Biology, Health Sciences Center, 3330 Hospital Drive NW, Calgary, Alberta, T2N 4N1, Canada.
| | | |
Collapse
|
12
|
Smith AME, Awuah E, Capretta A, Brennan JD. A matrix-assisted laser desorption/ionization tandem mass spectrometry method for direct screening of small molecule mixtures against an aminoglycoside kinase. Anal Chim Acta 2013; 786:103-10. [DOI: 10.1016/j.aca.2013.05.027] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2013] [Revised: 05/10/2013] [Accepted: 05/11/2013] [Indexed: 11/26/2022]
|
13
|
Liu C, Zhang Q, Kang J. Enzyme inhibitor screening by CE with an on-column immobilized enzyme microreactor created by an ionic binding technique. Methods Mol Biol 2013; 984:321-327. [PMID: 23386354 DOI: 10.1007/978-1-62703-296-4_23] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Enzymes are an important class of drug targets. In the early stage of the drug discovery, the major task is to find out the inhibitors of a given enzyme target in a compound library. Herein we describe a method for screening the enzyme inhibitors in the complex mixtures (such as the natural extracts) by capillary electrophoresis with an on-column immobilized enzyme microreactor. The enzyme molecules are immobilized on the capillary wall via ionic binding with the positively charged coating, which was created by simply flushing the column with a solution of polyelectrolyte hexadimethrine bromide. The activities of the immobilized enzymes are assayed by performing the electrophoretic separation and thereafter determining the product of the enzyme-mediated reaction. Enzyme inhibition can be read out directly from the reduced peak area of product in comparison with that in the reference electropherogram obtained in the absence of any inhibitor.
Collapse
Affiliation(s)
- Chao Liu
- Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai, PR China
| | | | | |
Collapse
|
14
|
Matsuda R, Anguizola J, Joseph K, Hage DS. Analysis of drug interactions with modified proteins by high-performance affinity chromatography: binding of glibenclamide to normal and glycated human serum albumin. J Chromatogr A 2012; 1265:114-22. [PMID: 23092871 PMCID: PMC3489001 DOI: 10.1016/j.chroma.2012.09.091] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2012] [Revised: 09/14/2012] [Accepted: 09/26/2012] [Indexed: 10/27/2022]
Abstract
High-performance affinity chromatography (HPAC) was used to examine the changes in binding that occur for the sulfonylurea drug glibenclamide with human serum albumin (HSA) at various stages of glycation for HSA. Frontal analysis on columns containing normal HSA or glycated HSA indicated glibenclamide was interacting through both high affinity sites (association equilibrium constant, K(a), 1.4-1.9 × 10(6)M(-1) at pH 7.4 and 37 °C) and lower affinity sites (K(a), 4.4-7.2 × 10(4)M(-1)). Competition studies were used to examine the effect of glycation at specific binding sites of HSA. An increase in affinity of 1.7- to 1.9-fold was seen at Sudlow site I with moderate to high levels of glycation. An even larger increase of 4.3- to 6.0-fold in affinity was noted at Sudlow site II for all of the tested samples of glycated HSA. A slight decrease in affinity may have occurred at the digitoxin site, but this change was not significant for any individual glycated HSA sample. These results illustrate how HPAC can be used as tool for examining the interactions of relatively non-polar drugs like glibenclamide with modified proteins and should lead to a more complete understanding of how glycation can alter the binding of drugs in blood.
Collapse
Affiliation(s)
- Ryan Matsuda
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304 (USA)
| | - Jeanethe Anguizola
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304 (USA)
| | - K.S. Joseph
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304 (USA)
| | - David S. Hage
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304 (USA)
| |
Collapse
|
15
|
Calleri E, Ambrosini S, Temporini C, Massolini G. New monolithic chromatographic supports for macromolecules immobilization: Challenges and opportunities. J Pharm Biomed Anal 2012; 69:64-76. [DOI: 10.1016/j.jpba.2012.01.032] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2011] [Revised: 01/19/2012] [Accepted: 01/20/2012] [Indexed: 01/15/2023]
|
16
|
Hage DS, Anguizola JA, Bi C, Li R, Matsuda R, Papastavros E, Pfaunmiller E, Vargas J, Zheng X. Pharmaceutical and biomedical applications of affinity chromatography: recent trends and developments. J Pharm Biomed Anal 2012; 69:93-105. [PMID: 22305083 DOI: 10.1016/j.jpba.2012.01.004] [Citation(s) in RCA: 126] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2011] [Revised: 01/04/2012] [Accepted: 01/06/2012] [Indexed: 10/14/2022]
Abstract
Affinity chromatography is a separation technique that has become increasingly important in work with biological samples and pharmaceutical agents. This method is based on the use of a biologically related agent as a stationary phase to selectively retain analytes or to study biological interactions. This review discusses the basic principles behind affinity chromatography and examines recent developments that have occurred in the use of this method for biomedical and pharmaceutical analysis. Techniques based on traditional affinity supports are discussed, but an emphasis is placed on methods in which affinity columns are used as part of HPLC systems or in combination with other analytical methods. General formats for affinity chromatography that are considered include step elution schemes, weak affinity chromatography, affinity extraction and affinity depletion. Specific separation techniques that are examined include lectin affinity chromatography, boronate affinity chromatography, immunoaffinity chromatography, and immobilized metal ion affinity chromatography. Approaches for the study of biological interactions by affinity chromatography are also presented, such as the measurement of equilibrium constants, rate constants, or competition and displacement effects. In addition, related developments in the use of immobilized enzyme reactors, molecularly imprinted polymers, dye ligands and aptamers are briefly considered.
Collapse
Affiliation(s)
- David S Hage
- Chemistry Department, University of Nebraska, Lincoln, NE 68588-0304, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Forsberg EM, Green JRA, Brennan JD. Continuous Flow Immobilized Enzyme Reactor–Tandem Mass Spectrometry for Screening of AChE Inhibitors in Complex Mixtures. Anal Chem 2011; 83:5230-6. [PMID: 21591743 DOI: 10.1021/ac200534t] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Erica M. Forsberg
- Department of Chemistry and Chemical Biology, McMaster University, 1280 Main Street West, Hamilton, ON, Canada L8S 4M1
| | - James R. A. Green
- Department of Chemistry and Chemical Biology, McMaster University, 1280 Main Street West, Hamilton, ON, Canada L8S 4M1
| | - John D. Brennan
- Department of Chemistry and Chemical Biology, McMaster University, 1280 Main Street West, Hamilton, ON, Canada L8S 4M1
| |
Collapse
|
18
|
Vuignier K, Schappler J, Veuthey JL, Carrupt PA, Martel S. Drug-protein binding: a critical review of analytical tools. Anal Bioanal Chem 2010; 398:53-66. [PMID: 20454782 DOI: 10.1007/s00216-010-3737-1] [Citation(s) in RCA: 271] [Impact Index Per Article: 19.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2010] [Revised: 04/08/2010] [Accepted: 04/08/2010] [Indexed: 11/26/2022]
Abstract
The extent of drug binding to plasma proteins, determined by measuring the free active fraction, has a significant effect on the pharmacokinetics and pharmacodynamics of a drug. It is therefore highly important to estimate drug-binding ability to these macromolecules in the early stages of drug discovery and in clinical practice. Traditionally, equilibrium dialysis is used, and is presented as the reference method, but it suffers from many drawbacks. In an attempt to circumvent these, a vast array of different methods has been developed. This review focuses on the most important approaches used to characterize drug-protein binding. A description of the principle of each method with its inherent strengths and weaknesses is outlined. The binding affinity ranges, information accessibility, material consumption, and throughput are compared for each method. Finally, a discussion is included to help users choose the most suitable approach from among the wealth of methods presented.
Collapse
Affiliation(s)
- Karine Vuignier
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Quai E-Ansermet 30, 1211 Geneva 4, Switzerland
| | | | | | | | | |
Collapse
|
19
|
Yoo MJ, Hage DS. Evaluation of silica monoliths in affinity microcolumns for high-throughput analysis of drug-protein interactions. J Sep Sci 2009; 32:2776-85. [PMID: 19630007 PMCID: PMC2765799 DOI: 10.1002/jssc.200900346] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Silica monoliths in affinity microcolumns were tested for the high-throughput analysis of drug-protein interactions. HSA was used as a model protein for this work, while carbamazepine and R-warfarin were used as model analytes. A comparison of HSA silica monoliths of various lengths indicated columns as short as 1 to 3 mm could be used to provide reproducible estimates of retention factors or plate heights. Benefits of using smaller columns for this work included the lower retention times and lower back pressures that could be obtained versus traditional HPLC affinity columns, as well as the smaller amount of protein that is required for column preparation. One disadvantage of decreasing column length was the lower precision that resulted in retention factor and plate height measurements. A comparison was also made between microcolumns containing silica particles versus silica monoliths. It was demonstrated with R-warfarin that supports could be used in HSA microcolumns for the determination of retention factors or plate heights. However, the higher efficiency of the silica monolith made this the preferred support for work at higher flow rates or when a larger number of plates are needed during the rapid analysis of drug-protein interactions.
Collapse
Affiliation(s)
- Michelle J. Yoo
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304 (USA)
| | - David S. Hage
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304 (USA)
| |
Collapse
|
20
|
Calleri E, Temporini C, Caccialanza G, Massolini G. Target-Based Drug Discovery: the Emerging Success of Frontal Affinity Chromatography Coupled to Mass Spectrometry. ChemMedChem 2009; 4:905-16. [DOI: 10.1002/cmdc.200800436] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
21
|
SAKAI-KATO K, ISHIKURA K. Integration of Biomolecules into Analytical Systems by Means of Silica Sol-Gel Technology. ANAL SCI 2009; 25:969-78. [DOI: 10.2116/analsci.25.969] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
| | - Keiko ISHIKURA
- Division of Drugs, National Institute of Health Sciences
| |
Collapse
|
22
|
Cademartiri R, Brook MA, Pelton R, Brennan JD. Macroporous silica using a “sticky” Stöber process. ACTA ACUST UNITED AC 2009. [DOI: 10.1039/b815447c] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
23
|
Development of an immobilized GPR17 receptor stationary phase for binding determination using frontal affinity chromatography coupled to mass spectrometry. Anal Biochem 2008; 384:123-9. [PMID: 18835238 DOI: 10.1016/j.ab.2008.09.010] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2008] [Revised: 08/14/2008] [Accepted: 09/08/2008] [Indexed: 11/23/2022]
Abstract
A liquid chromatographic stationary phase containing immobilized membranes from cells expressing the P2Y-like receptor GPR17 is described. Cellular membranes from 1321N1 cells transiently transfected with GPR17 vector [GPR17+] and from the same cell line transfected with the corresponding empty vector [GPR17(-)] were entrapped on immobilized artificial membrane (IAM) support and packed into 6.6-mm-i.d. glass columns to create GPR17(+)-IAM and GPR17(-)-IAM stationary phases. Frontal chromatography experiments on both GPR17(+)-IAM and GPR17(-)-IAM demonstrated the presence of a specific interaction with GPR17 only in the former that was maximized by increasing the membrane/IAM ratio. GPR17(+)-IAM was used in frontal affinity chromatography experiments to calculate the dissociation constants (K(d)) of three ligands-the antagonist cangrelor (formerly AR-C69931MX, a P2Y(12)/P2Y(13) antagonist), MRS2179 (a P2Y(1) receptor antagonist), and the agonist UDP-all of which have been reported to also interact with GPR17. Immobilized GPR17 retained its ability to specifically bind the three analytes, as demonstrated by the agreement of the calculated K(d) values with previously reported data. Preliminary ranking experiments suggest the application of GPR17(+)-IAM in ranking affinity studies for the selection of new potential candidates.
Collapse
|
24
|
Lebert JM, Forsberg EM, Brennan JD. Solid-phase assays for small molecule screening using sol-gel entrapped proteins. Biochem Cell Biol 2008; 86:100-10. [PMID: 18443623 DOI: 10.1139/o08-010] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
With compound libraries exceeding one million compounds, the ability to quickly and effectively screen these compounds against relevant pharmaceutical targets has become crucial. Solid-phase assays present several advantages over solution-based methods. For example, a higher degree of miniaturization can be achieved, functional- and affinity-based studies are possible, and a variety of detection methods can be used. Unfortunately, most protein immobilization methods are either too harsh or require recombinant proteins and thus are not amenable to delicate proteins such as kinases and membrane-bound receptors. Sol-gel encapsulation of proteins in an inorganic silica matrix has emerged as a novel solid-phase assay platform. In this minireview, we discuss the development of sol-gel derived protein microarrays and sol-gel based monolithic bioaffinity columns for the high-throughput screening of small molecule libraries and mixtures.
Collapse
Affiliation(s)
- Julie M Lebert
- Chemical Biology Program, Department of Chemistry, McMaster University, 1280 Main St. W, Hamilton, ON L8S4M1, Canada
| | | | | |
Collapse
|
25
|
Sharma J, Besanger TR, Brennan JD. Assaying Small-Molecule−Receptor Interactions by Continuous Flow Competitive Displacement Chromatography/Mass Spectrometry. Anal Chem 2008; 80:3213-20. [DOI: 10.1021/ac702421e] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Jai Sharma
- Department of Chemistry, McMaster University, Hamilton, Ontario L8S 4M1, Canada
| | - Travis R. Besanger
- Department of Chemistry, McMaster University, Hamilton, Ontario L8S 4M1, Canada
| | - John D. Brennan
- Department of Chemistry, McMaster University, Hamilton, Ontario L8S 4M1, Canada
| |
Collapse
|
26
|
Ng ESM, Chan NWC, Lewis DF, Hindsgaul O, Schriemer DC. Frontal affinity chromatography-mass spectrometry. Nat Protoc 2007; 2:1907-17. [PMID: 17703202 DOI: 10.1038/nprot.2007.262] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Frontal affinity chromatography (FAC) is a biophysical method for the discovery and characterization of molecular interactions in a flow-based system. Several different modes of analysis are possible by interfacing to the mass spectrometer, including robust single-compound characterizations as well as high-throughput screening of over 1,000 compounds per run. The method supports thermodynamic and kinetic characterization of interactions for a wide range of molecular species and possesses similarities to flow-based biosensors such as surface plasmon resonance. It offers sensitive detection of ligands present well below their respective dissociation constants, and can be assembled from readily available laboratory components. Direct coupling of the FAC cartridge to the mass spectrometer is useful for the interrogation of single compounds or mixtures of limited complexity. An offline fractionation schema is more appropriate for discovery-mode applications. A high-performance FAC system enabling both modes can be assembled in 2-3 h. Measurements of dissociation constants can be made with such a system in 0.5-3 h, and the system supports higher-throughput screening modes at a rate of 10,000 compounds d(-1).
Collapse
Affiliation(s)
- Ella S M Ng
- Department of Biochemistry and Molecular Biology, University of Calgary, Calgary, Alberta, Canada
| | | | | | | | | |
Collapse
|
27
|
Affinity selection-mass spectrometry screening techniques for small molecule drug discovery. Curr Opin Chem Biol 2007; 11:518-26. [PMID: 17931956 DOI: 10.1016/j.cbpa.2007.07.011] [Citation(s) in RCA: 151] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2007] [Revised: 07/21/2007] [Accepted: 07/27/2007] [Indexed: 11/24/2022]
|
28
|
Rupcich N, Nutiu R, Li Y, Brennan JD. Solid-phase enzyme activity assay utilizing an entrapped fluorescence-signaling DNA aptamer. Angew Chem Int Ed Engl 2007; 45:3295-9. [PMID: 16619330 DOI: 10.1002/anie.200504576] [Citation(s) in RCA: 56] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- Nicholas Rupcich
- Department of Chemistry, McMaster University, 1280 Main St. W. Hamilton, ON L8S 4M1, Canada
| | | | | | | |
Collapse
|
29
|
Chan N, Lewis D, Kelly M, Ng ESM, Schriemer DC. Frontal Affinity Chromatography – Mass Spectrometry for Ligand Discovery and Characterization. ACTA ACUST UNITED AC 2007. [DOI: 10.1002/9783527610907.ch6] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
30
|
Hodgson RJ, Besanger TR, Brook MA, Brennan JD. Inhibitor screening using immobilized enzyme reactor chromatography/mass spectrometry. Anal Chem 2007; 77:7512-9. [PMID: 16316156 DOI: 10.1021/ac050761q] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
We describe the coupling of capillary-scale monolithic enzyme reactor columns directly to a tandem mass spectrometer for screening of enzyme inhibitors. A two-channel nanoLC system is used to continuously infuse substrate or substrate/inhibitor mixtures through the column, allowing continuous variation of inhibitor concentration by simply altering the ratio of flow from the two pumps. In the absence of inhibitor, infusion of substrate leads to formation of product, and both substrate and product ions can be simultaneously monitored in a quantitative manner by MS/MS. The presence of inhibitor leads to a decrease in product and an increase in substrate concentration in the column eluent. Knowing the product/substrate ratio and the total analyte concentration (P + S), the concentration of product eluting, and hence the relative enzyme activity, can be determined. Both IC50 and KI values can then be obtained by direct MS detection of the effect of inhibitors on relative activity. Inhibitor screening is demonstrated using reusable, sol-gel derived, monolithic capillary columns containing adenosine deaminase, directly interfaced to ESI-MS/MS. On-column enzyme activity was assessed by monitoring inosine and adenosine elution. It is shown that the method can be used for automated screening of the effects of compound mixtures on ADA activity and to determine the KI value of the known inhibitor, erythro-9-(2-hydroxy-3-nonyl)adenine, even when the compound is present within a mixture.
Collapse
Affiliation(s)
- Richard J Hodgson
- Department of Chemistry, McMaster University, Hamilton, Ontario, Canada
| | | | | | | |
Collapse
|
31
|
Martic S, Brennan JD, Brook MA, Ackloo S, Nagy N. Towards the development of a covalently tethered MALDI system — A study of allyl-modified MALDI matrixes. CAN J CHEM 2007. [DOI: 10.1139/v06-185] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
An emerging application of matrix-assisted laser desorption ionization (MALDI) mass spectrometry is the analysis of low molecular weight (LMW) compounds, often via coupled liquid chromatography — MALDI-MS methods. However, in many cases, the low molecular weight region of MALDI mass spectra is obscured by the presence of signals originating from the matrix, suggesting that the development of tethered MALDI matrixes may be required to optimize MS performance for such compounds. To gain insight into potential sites for covalent attachment of MALDI matrixes, we have systematically investigated the role played by a variety of functional group motifs in determining matrix efficiency for three common MALDI matrixes, as judged both by total signal intensity and background noise from matrix decomposition for a set of LMW compounds. A series of allyl derivatives of standard matrixes was prepared, and the efficiency of these materials in the MALDI experiment was measured. All modifications of established matrixes, e.g., 2,5-dihydroxybenzoic acid (DHB), α-cyano-4-hydroxycinnamic acid (CHCA), and caffeic acid (CA), or close analogues led to decreased absolute signal intensity and signal-to-background levels. Improved performance was generally observed with (i) the presence of a phenolic group (carboxylic acids were less effective) (ii) crystalline derivatives, and (iii) compounds that had high extinction coefficients at wavelengths near to that of the exciting laser (337 nm). The most interesting derivatives were the O-allyl ether (15) and N-allyl amide (16) of caffeic acid. These compounds did not facilitate signals from all four analytes tested. However, the observed spectra contained fewer signals from the matrix than from the parent compound CA. These compounds demonstrate that functionalization of MALDI matrixes, ultimately leading to tethered matrixes, is possible without jeopardizing signal intensity.Key words: MALDI, protected matrix, phenol, caffeic acid, allyl ether.
Collapse
|
32
|
Abstract
The combined use of monolithic supports with selective affinity ligands as stationary phases has recently given rise to a new method known as affinity monolith chromatography (AMC). This review will discuss the basic principles behind AMC and examine the types of supports and ligands that have been employed in this method. Approaches for placing affinity ligands in monoliths will be considered, including methods based on covalent immobilization, biospecific adsorption, entrapment, and the formation of coordination complexes. Several reported applications will then be presented, such as the use of AMC for bioaffinity chromatography, immunoaffinity chromatography, immobilized metal-ion affinity chromatography, dye-ligand affinity chromatography, and biomimetic chromatography. Other applications that will be discussed are chiral separations and studies of biological interactions based on AMC.
Collapse
Affiliation(s)
- Rangan Mallik
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | | |
Collapse
|
33
|
Rupcich N, Nutiu R, Li Y, Brennan JD. Solid-Phase Enzyme Activity Assay Utilizing an Entrapped Fluorescence-Signaling DNA Aptamer. Angew Chem Int Ed Engl 2006. [DOI: 10.1002/ange.200504576] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
34
|
Tang ZM, Kang JW. Enzyme Inhibitor Screening by Capillary Electrophoresis with an on-Column Immobilized Enzyme Microreactor Created by an Ionic Binding Technique. Anal Chem 2006; 78:2514-20. [PMID: 16615758 DOI: 10.1021/ac052030w] [Citation(s) in RCA: 83] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
A novel strategy for screening the enzyme inhibitors from the complex mixtures by capillary electrophoresis with an on-column immobilized enzyme microreactor created by an ionic binding technique is reported. The enzyme microreactor was prepared in two steps: First, the capillary wall was dynamically coated with a polycationic electrolyte hexadimethrine bromide (HDB) by simply flushing the column using the HDB solution. Subsequently, a plug of the enzyme solution was injected and incubated for 5 min to permit the enzyme molecules to immobilize on the positively charged coating via ionic binding. To demonstrate this strategy, angiotensin-converting enzyme (ACE) was employed as a model for the enzyme immobilization, inhibition study, and inhibitor screening. It has been proved that such a prepared immobilized ACE microreactor displays a high enough activity and stability. Furthermore, the immobilized enzyme microreactor could be easily renewed. The inhibition study or inhibitor screening was accomplished through the following procedure: (i) the substrate solution was injected and incubated within the microreactor for a short time span; (ii) subsequently, the voltage was applied to separate the product of the enzyme reaction from the unreacted substrate based on their different mobilities, the peak area of the product representing the enzyme activity; (iii) a certain amount of enzyme inhibitor or candidate compound was spiked into the substrate solution to assay the reduction of the immobilized enzyme activity. Thus, the inhibitors can be easily identified if the reduced peak area of the product is observed in electropherograms. Because the injection volume of the capillary was only 9.8 nL and the enzyme could be reusable, the assay cost could be dramatically reduced. The screening of a small compound library containing natural extracts and commercially available inhibitors was performed. The present approach has proved to be simple, rapid, and robust.
Collapse
Affiliation(s)
- Zhong-Mei Tang
- Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Fenglin Road 354, Shanghai, 200032, China
| | | |
Collapse
|
35
|
Besanger TR, Hodgson RJ, Green JRA, Brennan JD. Immobilized enzyme reactor chromatography: Optimization of protein retention and enzyme activity in monolithic silica stationary phases. Anal Chim Acta 2006; 564:106-15. [PMID: 17723368 DOI: 10.1016/j.aca.2005.12.066] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2005] [Revised: 12/19/2005] [Accepted: 12/29/2005] [Indexed: 11/22/2022]
Abstract
Our group recently reported on the application of protein-doped monolithic silica columns for immobilized enzyme reactor chromatography, which allowed screening of enzyme inhibitors present in mixtures using mass spectrometry for detection. The enzyme was immobilized by entrapment within a bimodal meso/macroporous silica material prepared by a biocompatible sol-gel processing route. While such columns proved to be useful for applications such as screening of protein-ligand interactions, significant amounts of entrapped proteins leached from the columns owing to the high proportion of macropores within the materials. Herein, we describe a detailed study of factors affecting the morphology of protein-doped bioaffinity columns and demonstrate that specific pH values and concentrations of poly(ethylene glycol) can be used to prepare essentially mesoporous columns that retain over 80% of initially loaded enzyme in an active and accessible form and yet still retain sufficient porosity to allow pressure-driven flow in the low muL/min range. Using the enzyme gamma-glutamyl transpeptidase (gamma-GT), we further evaluated the catalytic constants of the enzyme entrapped in capillary columns with different silica morphologies as a function of flowrate and backpressure using the enzyme reactor assay mode. It was found that the apparent activity of the enzyme was highest in mesoporous columns that retained high levels of enzyme. In such columns, enzyme activity increased by approximately 2-fold with increases in both flowrate (from 250 to 1000 nL/min) and backpressure generated (from 500 to 2100 psi) during the chromatographic activity assay owing to increases in k(cat) and decreases in K(M), switching from diffusion controlled to reaction controlled conditions at ca. 2000 psi. These results suggest that columns with minimal macropore volumes (<5%) are advantageous for the entrapment of soluble proteins for bioaffinity and bioreactor chromatography.
Collapse
Affiliation(s)
- Travis R Besanger
- Department of Chemistry, McMaster University, 1280 Main St. West, Hamilton, Ont. L8S 4M1, Canada
| | | | | | | |
Collapse
|
36
|
Besanger TR, Hodgson RJ, Guillon D, Brennan JD. Monolithic membrane-receptor columns: Optimization of column performance for frontal affinity chromatography/mass spectrometry applications. Anal Chim Acta 2006. [DOI: 10.1016/j.aca.2005.12.062] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
37
|
Kato M, Saka-Kato K, Toyo'oka T. Miniaturization of an analytical system using immobilized biomolecules for high-throughput screening. Anal Bioanal Chem 2005; 384:50-2. [PMID: 16328236 DOI: 10.1007/s00216-005-0200-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2005] [Revised: 10/18/2005] [Accepted: 10/26/2005] [Indexed: 10/25/2022]
Affiliation(s)
- Masaru Kato
- Department of Analytical Chemistry, School of Pharmaceutical Sciences, COE Program in the 21st Century, University of Shizuoka, 52-1 Yada Suruga Shizuoka, 422-8526, Shizuoka, Japan.
| | | | | |
Collapse
|
38
|
Kato M, Sakai-Kato K, Toyo'oka T. Silica sol-gel monolithic materials and their use in a variety of applications. J Sep Sci 2005. [DOI: 10.1002/jssc.200500225] [Citation(s) in RCA: 92] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
39
|
Hodgson RJ, Brook MA, Brennan JD. Capillary-Scale Monolithic Immunoaffinity Columns for Immunoextraction with In-Line Laser-Induced Fluorescence Detection. Anal Chem 2005; 77:4404-12. [PMID: 16013853 DOI: 10.1021/ac048142p] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A bimodal meso/macroporous monolithic silica capillary column containing an entrapped antibody was prepared by a biocompatible sol-gel process and used for nanoflow immunoaffinity chromatography and immunoextraction studies. Stationary phases were prepared by combining the protein-compatible silane precursor diglycerylsilane with an aqueous solution containing 10,000 Da poly(ethylene glycol) and the antibody. An analytical method was developed that was capable of determining both the dissociation constant and binding site content for the anti-fluorescein antibody within the stationary phase. The assay showed that while the antibody residing in macropores was easily removed, approximately 20% of initially loaded antibody remained active and accessible after several washes, consistent with the antibody being entrapped within the mesopores of the sol-gel matrix. The dissociation constants for fluorescein binding to the anti-fluorescein antibody were similar in solution and in the meso/macroporous silica, indicating that the entrapped antibody retained its native conformation within such a matrix. The mixture was loaded into a 250-microm-i.d. fused-silica capillary where the polymer phase separated from the silica followed by gelation of the silica. The capillary-scale immunoaffinity columns could be operated at low back pressure using a syringe pump and were capable of performing chromatographic separations that were dependent on the presence of the antibody within the stationary phase. Such columns could also be operated using in-line laser-induced fluorescence detection. The use of the capillary-scale monolithic columns for on-column immunoextraction and preconcentration is also demonstrated.
Collapse
Affiliation(s)
- Richard J Hodgson
- Department of Chemistry, McMaster University, Hamilton, Ontario, L8S 4M1, Canada
| | | | | |
Collapse
|