1
|
Godage NH, Olomukoro AA, Emmons RV, Gionfriddo E. In vivo analytical techniques facilitated by contemporary materials. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116290] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
2
|
Baumann KY, Church MK, Clough GF, Quist SR, Schmelz M, Skov PS, Anderson CD, Tannert LK, Giménez-Arnau AM, Frischbutter S, Scheffel J, Maurer M. Skin microdialysis: methods, applications and future opportunities-an EAACI position paper. Clin Transl Allergy 2019; 9:24. [PMID: 31007896 PMCID: PMC6456961 DOI: 10.1186/s13601-019-0262-y] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2019] [Accepted: 03/25/2019] [Indexed: 12/20/2022] Open
Abstract
Skin microdialysis (SMD) is a versatile sampling technique that can be used to recover soluble endogenous and exogenous molecules from the extracellular compartment of human skin. Due to its minimally invasive character, SMD can be applied in both clinical and preclinical settings. Despite being available since the 1990s, the technique has still not reached its full potential use as a tool to explore pathophysiological mechanisms of allergic and inflammatory reactions in the skin. Therefore, an EAACI Task Force on SMD was formed to disseminate knowledge about the technique and its many applications. This position paper from the task force provides an overview of the current use of SMD in the investigation of the pathogenesis of chronic inflammatory skin diseases, such as atopic dermatitis, chronic urticaria, psoriasis, and in studies of cutaneous events during type 1 hypersensitivity reactions. Furthermore, this paper covers drug hypersensitivity, UVB-induced- and neurogenic inflammation, and drug penetration investigated by SMD. The aim of this paper is to encourage the use of SMD and to make the technique easily accessible by providing an overview of methodology and applications, supported by standardized operating procedures for SMD in vivo and ex vivo.
Collapse
Affiliation(s)
- Katrine Y Baumann
- RefLab ApS, Copenhagen, Denmark.,2Department of Immunology and Microbiology, University of Copenhagen, Copenhagen, Denmark
| | - Martin K Church
- 3Department of Dermatology and Allergy, Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117 Berlin, Germany
| | | | - Sven Roy Quist
- 5Clinic of Dermatology, Otto-von-Guericke University, Magdeburg, Germany.,Skin Center MDZ, Mainz, Germany
| | - Martin Schmelz
- 7Department of Experimental Pain Research, CBTM, Medical Faculty Mannheim, Heidelberg University, Heidelberg, Germany
| | - Per Stahl Skov
- RefLab ApS, Copenhagen, Denmark.,8Odense Research Center for Anaphylaxis (ORCA), Department of Dermatology and Allergy Center, Odense University Hospital, Odense, Denmark
| | - Chris D Anderson
- 9Department of Clinical and Experimental Medicine, Linköping University, Linköping, Sweden
| | - Line Kring Tannert
- 8Odense Research Center for Anaphylaxis (ORCA), Department of Dermatology and Allergy Center, Odense University Hospital, Odense, Denmark
| | - Ana Maria Giménez-Arnau
- 10Department of Dermatology, Hospital del Mar, Institut Mar d'Investigacions Mèdiques, Universitat Autònoma, Barcelona, Spain
| | - Stefan Frischbutter
- 3Department of Dermatology and Allergy, Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117 Berlin, Germany
| | - Jörg Scheffel
- 3Department of Dermatology and Allergy, Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117 Berlin, Germany
| | - Marcus Maurer
- 3Department of Dermatology and Allergy, Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117 Berlin, Germany
| |
Collapse
|
3
|
Hammarlund-Udenaes M. Microdialysis as an Important Technique in Systems Pharmacology—a Historical and Methodological Review. AAPS JOURNAL 2017; 19:1294-1303. [DOI: 10.1208/s12248-017-0108-2] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/26/2017] [Accepted: 06/01/2017] [Indexed: 01/03/2023]
|
4
|
Challenges for the in vivo quantification of brain neuropeptides using microdialysis sampling and LC-MS. Bioanalysis 2016; 8:1965-85. [PMID: 27554986 DOI: 10.4155/bio-2016-0119] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
In recent years, neuropeptides and their receptors have received an increased interest in neuropharmacological research. Although these molecules are considered relatively small compared with proteins, their in vivo quantification using microdialysis is more challenging than for small molecules. Low microdialysis recoveries, aspecific adsorption and the presence of various multiply charged precursor ions during ESI-MS/MS detection hampers the in vivo quantification of these low abundant biomolecules. Every step in the workflow, from sampling until analysis, has to be optimized to enable the sensitive analysis of these compounds in microdialysates.
Collapse
|
5
|
A Review on Microdialysis Calibration Methods: the Theory and Current Related Efforts. Mol Neurobiol 2016; 54:3506-3527. [PMID: 27189617 DOI: 10.1007/s12035-016-9929-8] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2016] [Accepted: 05/03/2016] [Indexed: 10/21/2022]
Abstract
Microdialysis is a sampling technique first introduced in the late 1950s. Although this technique was originally designed to study endogenous compounds in animal brain, it is later modified to be used in other organs. Additionally, microdialysis is not only able to collect unbound concentration of compounds from tissue sites; this technique can also be used to deliver exogenous compounds to a designated area. Due to its versatility, microdialysis technique is widely employed in a number of areas, including biomedical research. However, for most in vivo studies, the concentration of substance obtained directly from the microdialysis technique does not accurately describe the concentration of the substance on-site. In order to relate the results collected from microdialysis to the actual in vivo condition, a calibration method is required. To date, various microdialysis calibration methods have been reported, with each method being capable to provide valuable insights of the technique itself and its applications. This paper aims to provide a critical review on various calibration methods used in microdialysis applications, inclusive of a detailed description of the microdialysis technique itself to start with. It is expected that this article shall review in detail, the various calibration methods employed, present examples of work related to each calibration method including clinical efforts, plus the advantages and disadvantages of each of the methods.
Collapse
|
6
|
Chu J, Koudriavtsev V, Hjort K, Dahlin AP. Fluorescence imaging of macromolecule transport in high molecular weight cut-off microdialysis. Anal Bioanal Chem 2014; 406:7601-9. [PMID: 25286875 DOI: 10.1007/s00216-014-8192-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2014] [Revised: 08/29/2014] [Accepted: 09/15/2014] [Indexed: 11/30/2022]
Abstract
When microdialysis (MD) membrane exceeds molecular weight cut-off (MWCO) of 100 kDa, the fluid mechanics are in the ultrafiltration regime. Consequently, fluidic mass transport of macromolecules in the perfusate over the membrane may reduce the biological relevance of the sampling and cause an inflammatory response in the test subject. Therefore, a method to investigate the molecular transport of high MWCO MD is presented. An in vitro test chamber was fabricated to facilitate the fluorescent imaging of the MD sampling process, using fluoresceinylisothiocyanate (FITC) dextran and fluorescence microscopy. Qualitative studies on dextran behavior inside and outside the membrane were performed. Semiquantitative results showed clear dextran leakage from both 40 and 250 kDa dextran when 100 kDa MWCO membranes were used. Dextran 40 kDa leaked out with an order of magnitude higher concentration and the leakage pattern resembled more of a convective flow pattern compared with dextran 250 kDa, where the leakage pattern was more diffusion based. No leakage was observed when dextran 500 kDa was used as a colloid osmotic agent. The results in this study suggest that fluorescence imaging could be used as a method for qualitative and semiquantitative molecular transport and fluid dynamics studies of MD membranes and other hollow fiber catheter membranes.
Collapse
Affiliation(s)
- Jiangtao Chu
- Department of Engineering Sciences, Uppsala University, Box 534, 751 21, Uppsala, Sweden
| | | | | | | |
Collapse
|
7
|
Wetterhall M, Bergquist J, Hillered L, Hjort K, Dahlin AP. Identification of human cerebrospinal fluid proteins and their distribution in an in vitro microdialysis sampling system. Eur J Pharm Sci 2014; 57:34-40. [DOI: 10.1016/j.ejps.2013.12.011] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2013] [Accepted: 12/07/2013] [Indexed: 10/25/2022]
|
8
|
Wen XD, Yang J, Ma RH, Gao W, Qi LW, Li P, Bauer BA, Du GJ, Zhang Z, Somogyi J, Wang CZ, Yuan CS. Analysis of Panax notoginseng metabolites in rat bile by liquid chromatography-quadrupole time-of-flight mass spectrometry with microdialysis sampling. J Chromatogr B Analyt Technol Biomed Life Sci 2012; 895-896:162-8. [PMID: 22465198 PMCID: PMC3336018 DOI: 10.1016/j.jchromb.2012.03.009] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2011] [Revised: 02/18/2012] [Accepted: 03/07/2012] [Indexed: 01/07/2023]
Abstract
A dynamic microdialysis sampling method with liquid chromatography-quadrupole time-of-flight mass spectrometry (Q-TOF-MS) was developed for rapid and sensitive analysis of the metabolite profile of Panax notoginseng extract (PNE) in rat bile. In vivo studies in male Sprague-Dawley rats were performed with microdialysis probes implanted into the bile duct before bile samples were collected from 0 to 12h. Metabolites of PNE were identified using dynamic adjustment of the fragmentor voltage to produce structure-relevant fragment ions. The mass accuracy of precursor and fragment ions was typically within 5 ppm of the theoretical values. We identified 7 compounds: 4 parent compounds (notoginsenoside R1, ginsenosides Rg1, Rb1, and Rd) and 3 metabolites (ginsenosides Rg2, Rh2, and compound K). Data from this study suggest that this microdialysis technique could be used in notoginseng saponin metabolic animal studies.
Collapse
Affiliation(s)
- Xiao-Dong Wen
- Tang Center for Herbal Medicine Research and Department of Anesthesia & Critical Care, Pritzker School of Medicine, The University of Chicago, 5841 South Maryland Avenue, Chicago, Illinois, 60637, USA
- State Key Laboratory of Natural Medicines, China Pharmaceutical University, Nanjing 210009, China
| | - Jie Yang
- State Key Laboratory of Natural Medicines, China Pharmaceutical University, Nanjing 210009, China
| | - Rong-Hua Ma
- State Key Laboratory of Natural Medicines, China Pharmaceutical University, Nanjing 210009, China
| | - Wen Gao
- State Key Laboratory of Natural Medicines, China Pharmaceutical University, Nanjing 210009, China
| | - Lian-Wen Qi
- State Key Laboratory of Natural Medicines, China Pharmaceutical University, Nanjing 210009, China
| | - Ping Li
- State Key Laboratory of Natural Medicines, China Pharmaceutical University, Nanjing 210009, China
| | - Brent A. Bauer
- Complementary and Integrative Medicine Program, Mayo Clinic, Rochester, Minnesota 55905, USA
| | - Guang-Jian Du
- Tang Center for Herbal Medicine Research and Department of Anesthesia & Critical Care, Pritzker School of Medicine, The University of Chicago, 5841 South Maryland Avenue, Chicago, Illinois, 60637, USA
| | - Zhiyu Zhang
- Tang Center for Herbal Medicine Research and Department of Anesthesia & Critical Care, Pritzker School of Medicine, The University of Chicago, 5841 South Maryland Avenue, Chicago, Illinois, 60637, USA
| | - Jacqueline Somogyi
- Tang Center for Herbal Medicine Research and Department of Anesthesia & Critical Care, Pritzker School of Medicine, The University of Chicago, 5841 South Maryland Avenue, Chicago, Illinois, 60637, USA
| | - Chong-Zhi Wang
- Tang Center for Herbal Medicine Research and Department of Anesthesia & Critical Care, Pritzker School of Medicine, The University of Chicago, 5841 South Maryland Avenue, Chicago, Illinois, 60637, USA
| | - Chun-Su Yuan
- Tang Center for Herbal Medicine Research and Department of Anesthesia & Critical Care, Pritzker School of Medicine, The University of Chicago, 5841 South Maryland Avenue, Chicago, Illinois, 60637, USA
| |
Collapse
|
9
|
Holmgaard R, Benfeldt E, Nielsen JB, Gatschelhofer C, Sorensen JA, Höfferer C, Bodenlenz M, Pieber TR, Sinner F. Comparison of Open-Flow Microperfusion and Microdialysis Methodologies When Sampling Topically Applied Fentanyl and Benzoic Acid in Human Dermis Ex Vivo. Pharm Res 2012; 29:1808-20. [DOI: 10.1007/s11095-012-0705-9] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2011] [Accepted: 02/08/2012] [Indexed: 11/30/2022]
|
10
|
Prieto A, Rodil R, Quintana JB, Rodríguez I, Cela R, Möder M. Evaluation of low-cost disposable polymeric materials for sorptive extraction of organic pollutants in water samples. Anal Chim Acta 2011; 716:119-27. [PMID: 22284886 DOI: 10.1016/j.aca.2011.12.023] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2011] [Revised: 12/09/2011] [Accepted: 12/10/2011] [Indexed: 11/27/2022]
Abstract
The capabilities of four commercially available and low cost polymeric materials for the extraction of polar and non-polar contaminants (logK(ow)=-0.07-6.88, from caffeine to octocrylene, respectively) from water samples was compared. Tested sorbents were polyethersulphone, polypropylene and Kevlar, compared to polydimethylsiloxane as reference material. Parameters that affect the extraction process such as pH and ionic strength of the sample, extraction time and desorption conditions were thoroughly investigated. A set of experimental partition coefficients (K(pw)), at two different experimental conditions, was estimated for the best suited materials and compared with the theoretical octanol-water (K(ow)) partition coefficients of the analytes. Polyethersulphone displayed the largest extraction yields for both polar and non-polar analytes, with higher K(pw) and lower matrix effects than polydimethylsiloxane and polypropylene. Thus, a sorptive microextraction method, followed by large volume injection (LVI) gas chromatography-tandem mass spectrometry (GC-MS/MS), was proposed using the former sorbent (2 mg) for the simultaneous determination of model compounds in water samples. Good linearity (>0.99) was obtained for most of the analytes, except in the case of 4-nonylphenol (0.9466). Precision (n=4) at 50 and 500 ng L(-1) levels was in the 2-24% and limits of detection (LODs) were in the 0.6-25 ng L(-1) range for all the analytes studied.
Collapse
Affiliation(s)
- Ailette Prieto
- Department of Analytical Chemistry, University of the Basque Country, Bilbao, Spain.
| | | | | | | | | | | |
Collapse
|
11
|
Helmy A, De Simoni MG, Guilfoyle MR, Carpenter KLH, Hutchinson PJ. Cytokines and innate inflammation in the pathogenesis of human traumatic brain injury. Prog Neurobiol 2011; 95:352-72. [PMID: 21939729 DOI: 10.1016/j.pneurobio.2011.09.003] [Citation(s) in RCA: 158] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2011] [Revised: 09/04/2011] [Accepted: 09/06/2011] [Indexed: 01/31/2023]
Abstract
There is an increasing recognition that following traumatic brain injury, a cascade of inflammatory mediators is produced, and contributes to the pathological consequences of central nervous system injury. This review summarises the key literature from pre-clinical models that underlies our understanding of innate inflammation following traumatic brain injury before focussing on the growing evidence from human studies. In addition, the underlying molecular mediators responsible for blood brain barrier dysfunction have been discussed. In particular, we have highlighted the different sampling methodologies available and the difficulties in interpreting human data of this sort. Ultimately, understanding the innate inflammatory response to traumatic brain injury may provide a therapeutic avenue in the treatment of central nervous system disease.
Collapse
Affiliation(s)
- Adel Helmy
- Division of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge, Box 167, Addenbrooke's Hospital, Hills Road, Cambridge, CB2 0QQ, UK.
| | | | | | | | | |
Collapse
|
12
|
Ocular microdialysis: a continuous sampling technique to study pharmacokinetics and pharmacodynamics in the eye. Bioanalysis 2011; 2:487-507. [PMID: 21083257 DOI: 10.4155/bio.10.2] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
The unique anatomy and physiology of the eye present many challenges to the successful development and delivery of ophthalmic drugs. Any therapeutic strategy developed to control the progression of anterior and posterior segment diseases requires continuous monitoring of effective drug concentrations in the relevant ocular tissues and fluids. Ocular microdialysis has gained popularity in recent years due to its ability to continuously monitor drug concentrations and substantially reduce the number of animals needed. The intrusive nature of ocular microdialysis experimentation has restricted these studies to animal models. This review article intends to highlight various aspects of ocular microdialysis and its relevance in examining the disposition of drugs in the anterior and posterior segments.
Collapse
|
13
|
Bungay PM, Wang T, Yang H, Elmquist WF. Utilizing transmembrane convection to enhance solute sampling and delivery by microdialysis: theory and in vitro validation. J Memb Sci 2010; 348:131-149. [PMID: 20161534 DOI: 10.1016/j.memsci.2009.10.050] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Microdialysis is a well-developed membrane-based tool relying on diffusion to sample diffusible constituents of complex media, such as biological tissue. The objective of this research is to expand the utility of microdialysis by combining transmembrane convection with diffusion to enhance solute exchange between microdialysis probes and the surrounding medium. We have developed a mathematical model to describe probe performance and performed validation experiments utilizing tracer solutes and commercially available probes with 100-kDa molecular weight cutoff membranes. Diffusive and fluid permeabilities of the probe membranes are evaluated for probes immersed in well-stirred bathing media in vitro. Transmembrane convection alters the solute extraction fraction, i.e., the fractional loss of a solute from the probe perfusate during delivery and the fractional gain by the perfusate during sampling. The extraction fraction change depends upon the magnitude and direction (inward or outward) of fluid movement across the membrane. However, for solutes with zero reflection coefficients, equality is maintained between these delivery and sampling extraction fractions. This equality is a prerequisite for probe calibration approaches that rely on analyte delivery from the perfusate. Thus, we have provided the theoretical and experimental basis for exploiting convection in a quantitative manner to enhance solute delivery and sampling in microdialysis applications.
Collapse
Affiliation(s)
- Peter M Bungay
- Laboratory of Bioengineering and Physical Science, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, MD 20892
| | | | | | | |
Collapse
|
14
|
De Los Rios J, Sahuquillo J, Merino M, Poca M, Expósito L. Microdiálisis de alta resolución. Aspectos metodológicos y aplicación al estudio de la respuesta inflamatoria cerebral. Neurocirugia (Astur) 2009. [DOI: 10.1016/s1130-1473(09)70140-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|