1
|
Charlieux F, Abdoul-Carime H. Processes Induced by Electrons at Sub-Ionization Energies Studied by the Correlated Ions-(Ions/Neutrals) Mass Spectrometry. Chemphyschem 2022; 24:e202200722. [PMID: 36562329 DOI: 10.1002/cphc.202200722] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Revised: 12/16/2022] [Accepted: 12/16/2022] [Indexed: 12/24/2022]
Abstract
Sub-ionization energy electrons play a substantial role in the early time of (radiation/photo-) chemistry by generating reactive ions and neutral radicals. As the ions can be easily identified by mass spectrometry methods, information on the neutral species produced in correlation relies mainly on theoretical calculations. Here we show that coupling a double counter-propagative electron beams with a dual (+/-) time-of-flight mass spectrometer is probably the most versatile instrument for studying processes induced by low energy electrons, by providing correlated information between (ion and ion) and (ion and neutral) species. We demonstrate the feasibility of this technique for the prototypical case of carbon tetrachloride, but this method is generally applicable as shown for nitromethane.
Collapse
Affiliation(s)
- Florence Charlieux
- Université de Lyon, Université Lyon 1, Institut de Physique des 2 Infinis, CNRS/IN2P3, UMR5822, 69003, Lyon, France
| | - Hassan Abdoul-Carime
- Université de Lyon, Université Lyon 1, Institut de Physique des 2 Infinis, CNRS/IN2P3, UMR5822, 69003, Lyon, France
| |
Collapse
|
2
|
Xi Y, Muddiman DC. Enhancing Metabolomic Coverage in Positive Ionization Mode Using Dicationic Reagents by Infrared Matrix-Assisted Laser Desorption Electrospray Ionization. Metabolites 2021; 11:810. [PMID: 34940568 PMCID: PMC8708802 DOI: 10.3390/metabo11120810] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2021] [Revised: 11/19/2021] [Accepted: 11/23/2021] [Indexed: 11/16/2022] Open
Abstract
Mass spectrometry imaging is a powerful tool to analyze a large number of metabolites with their spatial coordinates collected throughout the sample. However, the significant differences in ionization efficiency pose a big challenge to metabolomic mass spectrometry imaging. To solve the challenge and obtain a complete data profile, researchers typically perform experiments in both positive and negative ionization modes, which is time-consuming. In this work, we evaluated the use of the dicationic reagent, 1,5-pentanediyl-bis(1-butylpyrrolidinium) difluoride (abbreviated to [C5(bpyr)2]F2) to detect a broad range of metabolites in the positive ionization mode by infrared matrix-assisted laser desorption electrospray ionization mass spectrometry imaging (IR-MALDESI MSI). [C5(bpyr)2]F2 at 10 µM was doped in 50% MeOH/H2O (v/v) electrospray solvent to form +1 charged adducted ions with anionic species (-1 charged) through post-electrospray ionization. This method was demonstrated with sectioned rat liver and hen ovary. A total of 73 deprotonated metabolites from rat liver tissue sections were successfully adducted with [C5(bpyr)2]2+ and putatively identified in the adducted positive ionization polarity, along with 164 positively charged metabolite ions commonly seen in positive ionization mode, which resulted in 44% increased molecular coverage. In addition, we were able to generate images of hen ovary sections showing their morphological features. Following-up tandem mass spectrometry (MS/MS) indicated that this dicationic reagent [C5(bpyr)2]2+ could form ionic bonds with the headgroup of glycerophospholipid ions. The addition of the dicationic reagent [C5(bpyr)2]2+ in the electrospray solvent provides a rapid and effective way to enhance the detection of metabolites in positive ionization mode.
Collapse
Affiliation(s)
- Ying Xi
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695, USA;
| | - David C. Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695, USA;
- Molecular Education, Technology and Research Innovation Center (METRIC), North Carolina State University, Raleigh, NC 27695, USA
| |
Collapse
|
3
|
Müller WH, De Pauw E, Far J, Malherbe C, Eppe G. Imaging lipids in biological samples with surface-assisted laser desorption/ionization mass spectrometry: A concise review of the last decade. Prog Lipid Res 2021; 83:101114. [PMID: 34217733 DOI: 10.1016/j.plipres.2021.101114] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Revised: 06/25/2021] [Accepted: 06/29/2021] [Indexed: 02/06/2023]
Abstract
Knowing the spatial location of the lipid species present in biological samples is of paramount importance for the elucidation of pathological and physiological processes. In this context, mass spectrometry imaging (MSI) has emerged as a powerful technology allowing the visualization of the spatial distributions of biomolecules, including lipids, in complex biological samples. Among the different ionization methods available, the emerging surface-assisted laser desorption/ionization (SALDI) MSI offers unique capabilities for the study of lipids. This review describes the specific advantages of SALDI-MSI for lipid analysis, including the ability to perform analyses in both ionization modes with the same nanosubstrate, the detection of lipids characterized by low ionization efficiency in MALDI-MS, and the possibilities of surface modification to improve the detection of lipids. The complementarity of SALDI and MALDI-MSI is also discussed. Finally, this review presents data processing strategies applied in SALDI-MSI of lipids, as well as examples of applications of SALDI-MSI in biomedical lipidomics.
Collapse
Affiliation(s)
- Wendy H Müller
- Mass Spectrometry Laboratory, MolSys RU, Department of Chemistry, University of Liège, Allée du Six Août, 11 - Quartier Agora, 4000 Liège, Belgium
| | - Edwin De Pauw
- Mass Spectrometry Laboratory, MolSys RU, Department of Chemistry, University of Liège, Allée du Six Août, 11 - Quartier Agora, 4000 Liège, Belgium
| | - Johann Far
- Mass Spectrometry Laboratory, MolSys RU, Department of Chemistry, University of Liège, Allée du Six Août, 11 - Quartier Agora, 4000 Liège, Belgium
| | - Cedric Malherbe
- Mass Spectrometry Laboratory, MolSys RU, Department of Chemistry, University of Liège, Allée du Six Août, 11 - Quartier Agora, 4000 Liège, Belgium
| | - Gauthier Eppe
- Mass Spectrometry Laboratory, MolSys RU, Department of Chemistry, University of Liège, Allée du Six Août, 11 - Quartier Agora, 4000 Liège, Belgium.
| |
Collapse
|
4
|
Dual-polarity SALDI FT-ICR MS imaging and Kendrick mass defect data filtering for lipid analysis. Anal Bioanal Chem 2020; 413:2821-2830. [PMID: 33125540 DOI: 10.1007/s00216-020-03020-w] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 09/30/2020] [Accepted: 10/20/2020] [Indexed: 12/16/2022]
Abstract
Lipids are biomolecules of crucial importance involved in critical biological functions. Yet, lipid content determination using mass spectrometry is still challenging due to their rich structural diversity. Preferential ionisation of the different lipid species in the positive or negative polarity is common, especially when using soft ionisation mass spectrometry techniques. Here, we demonstrate the potency of a dual-polarity approach using surface-assisted laser desorption/ionisation coupled to Fourier transform-ion cyclotron resonance (SALDI FT-ICR) mass spectrometry imaging (MSI) combined with Kendrick mass defect data filtering to (i) identify the lipids detected in both polarities from the same tissue section and (ii) show the complementarity of the dual-polarity data, both regarding the lipid coverage and the spatial distributions of the various lipids. For this purpose, we imaged the same mouse brain section in the positive and negative ionisation modes, on alternate pixels, in a SALDI FT-ICR MS imaging approach using gold nanoparticles (AuNPs) as dual-polarity nanosubstrates. Our study demonstrates, for the first time, the feasibility of (i) a dual-polarity SALDI-MSI approach on the same tissue section, (ii) using AuNPs as nanosubstrates combined with a FT-ICR mass analyser and (iii) the Kendrick mass defect data filtering applied to SALDI-MSI data. In particular, we show the complementarity in the lipids detected both in a given ionisation mode and in the two different ionisation modes. Graphical abstract.
Collapse
|
5
|
Dexter A, Steven RT, Patel A, Dailey LA, Taylor AJ, Ball D, Klapwijk J, Forbes B, Page CP, Bunch J. Imaging drugs, metabolites and biomarkers in rodent lung: a DESI MS strategy for the evaluation of drug-induced lipidosis. Anal Bioanal Chem 2019; 411:8023-8032. [PMID: 31776643 PMCID: PMC6920235 DOI: 10.1007/s00216-019-02151-z] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Revised: 08/30/2019] [Accepted: 09/12/2019] [Indexed: 12/17/2022]
Abstract
Within drug development and pre-clinical trials, a common, significant and poorly understood event is the development of drug-induced lipidosis in tissues and cells. In this manuscript, we describe a mass spectrometry imaging strategy, involving repeated analysis of tissue sections by DESI MS, in positive and negative polarities, using MS and MS/MS modes. We present results of the detected distributions of the administered drug, drug metabolites, lipid molecules and a putative marker of lipidosis, di-docosahexaenoyl (22:6)-bis(monoacylglycerol) phosphate (di-22:6-BMP). A range of strategies have previously been reported for detection, isolation and identification of this compound, which is an isomer of di-docosahexaenoic (22:6 n-3) phosphatidylglycerol (di-22:6 PG), a commonly found lipid that acts as a surfactant in lung tissues. We show that MS imaging using MS/MS can be used to differentiate these compounds of identical mass, based upon the different distributions of abundant fragment ions. Registration of images of these fragments, and detected drugs and metabolites, is presented as a new method for studying drug-induced lipidosis in tissues. Graphical abstract.
Collapse
Affiliation(s)
- Alex Dexter
- National Physical Laboratory, Teddington, London, TW11 0LW, UK
| | - Rory T Steven
- National Physical Laboratory, Teddington, London, TW11 0LW, UK
| | - Aateka Patel
- Institute of Pharmaceutical Science, King's College London, London, WC2R 2LS, UK
| | - Lea Ann Dailey
- Institute of Pharmaceutical Science, King's College London, London, WC2R 2LS, UK
- Martin-Luther-Universität Halle-Wittenberg, 06108, Halle, Saxony-Anhalt, Germany
| | - Adam J Taylor
- National Physical Laboratory, Teddington, London, TW11 0LW, UK
| | - Doug Ball
- Immunoinflammation TAU, GlaxoSmithKline, Stevenage, SG1 2NY, UK
| | - Jan Klapwijk
- Immunoinflammation TAU, GlaxoSmithKline, Stevenage, SG1 2NY, UK
| | - Ben Forbes
- Institute of Pharmaceutical Science, King's College London, London, WC2R 2LS, UK
| | - Clive P Page
- Institute of Pharmaceutical Science, King's College London, London, WC2R 2LS, UK
| | - Josephine Bunch
- National Physical Laboratory, Teddington, London, TW11 0LW, UK.
- Department of Surgery and Cancer, Faculty of Medicine, Imperial College, London, SW7 1LY, UK.
| |
Collapse
|
6
|
Attah IK, Garimella SVB, Webb IK, Nagy G, Norheim RV, Schimelfenig CE, Ibrahim YM, Smith RD. Dual Polarity Ion Confinement and Mobility Separations. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2019; 30:967-976. [PMID: 30834510 PMCID: PMC6520127 DOI: 10.1007/s13361-019-02138-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2018] [Revised: 01/18/2019] [Accepted: 01/18/2019] [Indexed: 05/12/2023]
Abstract
Here, we present simulations and describe the initial implementation of a device capable of performing simultaneous ion mobility (IM) separations of positive and negative ions based upon the structures for lossless ion manipulations (SLIM). To achieve dual polarity ion confinement, the DC fields used for lateral confinement in previous SLIM were replaced with RF fields. Concurrent ion transport and mobility separation in the SLIM device are shown possible due to the nature of the traveling wave (TW) voltage profile which has potential minima at opposite sides of the wave for each ion polarity. We explored the potential for performing simultaneous IM separations of cations and anions over the same SLIM path and the impacts on the achievable IM resolution and resolving power. Initial results suggest comparable IM performance with previous single-polarity SLIM separations can be achieved. We also used ion trajectory simulations to investigate the capability to manipulate the spatial distributions of ion populations based on their polarities by biasing the RF fields and TW potentials on each SLIM surface so as to limit the interactions between opposite polarity ions. Graphical Abstract.
Collapse
Affiliation(s)
- Isaac K Attah
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, USA
| | | | - Ian K Webb
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, USA
| | - Gabe Nagy
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, USA
| | - Randolph V Norheim
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, USA
| | - Colby E Schimelfenig
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, USA
| | - Yehia M Ibrahim
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, USA.
| | - Richard D Smith
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, USA.
| |
Collapse
|
7
|
He M, Jiang Y, Guo D, Xiong X, Fang X, Xu W. Dual-Polarity Ion Trap Mass Spectrometry: Dynamic Monitoring and Controlling Gas-phase Ion-Ion Reactions. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:1262-1270. [PMID: 28547725 DOI: 10.1007/s13361-016-1504-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2016] [Revised: 08/29/2016] [Accepted: 09/08/2016] [Indexed: 06/07/2023]
Abstract
A dual-polarity linear ion trap (LIT) mass spectrometer was developed in this study, and the method for simultaneously controlling and detecting cations and anions was proposed and realized in the LIT. With the application of an additional dipolar DC field on the ejection electrodes of an LIT, dual-polarity mass spectra could be obtained, which include both the mass-to-charge (m/z) ratio and charge polarity information of an ion. Compared with conventional method, the ion ejection and detection efficiency could also be improved by about one-fold. Furthermore, ion-ion reactions within the LIT could be dynamically controlled and monitored by manipulating the distributions of ions with opposite charge polarities. This method was then used to control and study the reaction kinetics of ion-ion reactions, including electron transfer dissociation (ETD) and charge inversion reactions. A dual-polarity collision-induced dissociation (CID) experiment was proposed and performed to enhance the sequence coverage of a peptide ion. Ion trajectory simulations were also carried out for concept validation and system optimization. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Muyi He
- School of Life Science, Beijing Institute of Technology, Beijing, 100081, China
| | - You Jiang
- National Institute of Metrology, Beijing, 100013, China
| | - Dan Guo
- School of Life Science, Beijing Institute of Technology, Beijing, 100081, China
| | | | - Xiang Fang
- National Institute of Metrology, Beijing, 100013, China.
| | - Wei Xu
- School of Life Science, Beijing Institute of Technology, Beijing, 100081, China.
- State Key Laboratory Explosion Science and Technology, Beijing Institute of Technology, Beijing, 100081, China.
- Key Laboratory of Convergence Medical Engineering System and Healthcare Technology, the Ministry of Industry and Information Technology, Beijing Institute of Technology, Beijing, 100081, China.
| |
Collapse
|
8
|
Zeegers GP, Günthardt BF, Zenobi R. Target Plate Material Influence on Fullerene-C60 Laser Desorption/Ionization Efficiency. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2016; 27:699-708. [PMID: 26894888 DOI: 10.1007/s13361-016-1333-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/10/2015] [Revised: 12/03/2015] [Accepted: 12/30/2015] [Indexed: 06/05/2023]
Abstract
Systematic laser desorption/ionization (LDI) experiments of fullerene-C60 on a wide range of target plate materials were conducted to gain insight into the initial ion formation in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. The positive and negative ion signal intensities of precursor, fragment, and cluster ions were monitored, varying both the laser fluence (0-3.53 Jcm(-2)) and the ion extraction delay time (0-950 ns). The resulting species-specific ion signal intensities are an indication for the ionization mechanisms that contribute to LDI and the time frames in which they operate, providing insight in the (MA)LDI primary ionization. An increasing electrical resistivity of the target plate material increases the fullerene-C60 precursor and fragment anion signal intensity. Inconel 625 and Ti90/Al6/V4, both highly electrically resistive, provide the highest anion signal intensities, exceeding the cation signal intensity by a factor ~1.4 for the latter. We present a mechanism based on transient electrical field strength reduction to explain this trend. Fullerene-C60 cluster anion formation is negligible, which could be due to the high extraction potential. Cluster cations, however, are readily formed, although for high laser fluences, the preferred channel is formation of precursor and fragment cations. Ion signal intensity depends greatly on the choice of substrate material, and careful substrate selection could, therefore, allow for more sensitive (MA)LDI measurements. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Guido P Zeegers
- Department of Chemistry and Applied Biosciences, ETH Zürich, Vladimir-Prelog-Weg 3, CH-8093, Zürich, Switzerland
| | - Barbara F Günthardt
- Department of Chemistry and Applied Biosciences, ETH Zürich, Vladimir-Prelog-Weg 3, CH-8093, Zürich, Switzerland
| | - Renato Zenobi
- Department of Chemistry and Applied Biosciences, ETH Zürich, Vladimir-Prelog-Weg 3, CH-8093, Zürich, Switzerland.
| |
Collapse
|
9
|
Alonso E, Zenobi R. Non-linear photoelectron effect contributes to the formation of negative matrix ions in UV-MALDI. Phys Chem Chem Phys 2016; 18:19574-87. [DOI: 10.1039/c6cp00649c] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The mechanism of negative ion formation in matrix-assisted laser desorption/ionization (MALDI) is less well understood than that of positive ions: electron capture, disproportionation, and liberation of negatively charged sample molecules or clusters have been proposed to produce the initial anions in MALDI.
Collapse
Affiliation(s)
- E. Alonso
- Department of Chemistry and Applied Biosciences
- ETH Zürich
- CH-8093 Zürich
- Switzerland
| | - R. Zenobi
- Department of Chemistry and Applied Biosciences
- ETH Zürich
- CH-8093 Zürich
- Switzerland
| |
Collapse
|
10
|
Lai YH, Wang CC, Chen CW, Liu BH, Lin SH, Lee YT, Wang YS. Analysis of Initial Reactions of MALDI Based on Chemical Properties of Matrixes and Excitation Condition. J Phys Chem B 2012; 116:9635-43. [DOI: 10.1021/jp304709q] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Affiliation(s)
- Yin-Hung Lai
- Genomics Research
Center, Academia Sinica, Taipei 115, Taiwan
| | - Chia-Chen Wang
- Genomics Research
Center, Academia Sinica, Taipei 115, Taiwan
- Institute of Biochemistry and
Molecular Biology, National Yang-Ming University, Taipei 112, Taiwan
| | - Chiu Wen Chen
- Genomics Research
Center, Academia Sinica, Taipei 115, Taiwan
| | - Bo-Hong Liu
- Genomics Research
Center, Academia Sinica, Taipei 115, Taiwan
| | - Sheng Hsien Lin
- Department
of Applied Chemistry, National Chiao Tung University, Hsinchu 300, Taiwan
| | - Yuan Tseh Lee
- Genomics Research
Center, Academia Sinica, Taipei 115, Taiwan
| | - Yi-Sheng Wang
- Genomics Research
Center, Academia Sinica, Taipei 115, Taiwan
- Institute of Biochemistry and
Molecular Biology, National Yang-Ming University, Taipei 112, Taiwan
| |
Collapse
|
11
|
Mädler S, Barylyuk K, Boeri Erba E, Nieckarz RJ, Zenobi R. Compelling advantages of negative ion mode detection in high-mass MALDI-MS for homomeric protein complexes. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2012; 23:213-224. [PMID: 22131225 DOI: 10.1007/s13361-011-0274-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2011] [Revised: 10/04/2011] [Accepted: 10/08/2011] [Indexed: 05/31/2023]
Abstract
Chemical cross-linking in combination with high-mass MALDI mass spectrometry allows for the rapid identification of interactions and determination of the complex stoichiometry of noncovalent protein-protein interactions. As the molecular weight of these complexes increases, the fraction of multiply charged species typically increases. In the case of homomeric complexes, signals from multiply charged multimers overlap with singly charged subunits. Remarkably, spectra recorded in negative ion mode show lower abundances of multiply charged species, lower background, higher reproducibility, and, thus, overall cleaner spectra compared with positive ion mode spectra. In this work, a dedicated high-mass detector was applied for measuring high-mass proteins (up to 200 kDa) by negative ion mode MALDI-MS. The influences of sample preparation and instrumental parameters were carefully investigated. Relative signal integrals of multiply charged anions were relatively independent of any of the examined parameters and could thus be approximated easily for the spectra of cross-linked complexes. For example, the fraction of doubly charged anions signals overlapping with the signals of singly charged subunits could be more precisely estimated than in positive ion mode. Sinapinic acid was found to be an excellent matrix for the analysis of proteins and cross-linked protein complexes in both ion modes. Our results suggest that negative ion mode data of chemically cross-linked protein complexes are complementary to positive ion mode data and can in some cases represent the solution phase situation better than positive ion mode.
Collapse
Affiliation(s)
- Stefanie Mädler
- Department of Chemistry and Applied Biosciences, ETH Zurich, 8093 Zurich, Switzerland
| | | | | | | | | |
Collapse
|
12
|
Huang MZ, Cheng SC, Cho YT, Shiea J. Ambient ionization mass spectrometry: A tutorial. Anal Chim Acta 2011; 702:1-15. [PMID: 21819855 DOI: 10.1016/j.aca.2011.06.017] [Citation(s) in RCA: 223] [Impact Index Per Article: 15.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2011] [Revised: 06/07/2011] [Accepted: 06/07/2011] [Indexed: 10/18/2022]
|
13
|
Hsiao CH, Hong CW, Liu BH, Chen CW, Wu CC, Wang YS. Comprehensive molecular imaging of photolabile surface samples with synchronized dual-polarity time-of-flight mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2011; 25:834-42. [PMID: 21416519 DOI: 10.1002/rcm.4914] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/05/2010] [Revised: 12/21/2010] [Accepted: 12/21/2010] [Indexed: 05/24/2023]
Abstract
This work presents the unique features of a novel configuration of a synchronized dual-polarity time-of-flight mass spectrometer for comprehensive surface imaging. Mass spectrometry imaging of surface samples covering positive and negative ion modes is difficult due to rapid signal depletion. This limitation is overcome here by dual-polarity time-of-flight mass spectrometry (DP-TOFMS) via two separate TOF mass analyzers that are installed above a sample surface. The new instrument eliminates the polarity bias characteristic of most mass spectrometers, which is important for the analysis of samples with diverse physical and chemical properties. The experimental results show for the first time that the spatial distribution of positive and negative ions of various photolabile samples can be distinguished, including pigments and conventional matrix-assisted laser desorption/ionization samples. The different positive and negative ion distributions suggest that accurate quantitative information can only be obtained when the entire sample region is examined by DP-TOFMS, which was unfeasible in the past. Such a comprehensive diagnostic method is essential for the molecular imaging of trace compositions in delicate biological tissues, as demonstrated here with a Phyllanthus urinaria leaf that only produced ion signals in the first examination and not in the subsequent measurements.
Collapse
Affiliation(s)
- Chih-Hao Hsiao
- Genomics Research Center, Academia Sinica, Taipei 115, Taiwan
| | | | | | | | | | | |
Collapse
|
14
|
Watrous JD, Alexandrov T, Dorrestein PC. The evolving field of imaging mass spectrometry and its impact on future biological research. JOURNAL OF MASS SPECTROMETRY : JMS 2011; 46:209-22. [PMID: 21322093 PMCID: PMC3303182 DOI: 10.1002/jms.1876] [Citation(s) in RCA: 79] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2010] [Accepted: 11/30/2010] [Indexed: 05/20/2023]
Abstract
Within the past decade, imaging mass spectrometry (IMS) has been increasingly recognized as an indispensable technique for studying biological systems. Its rapid evolution has resulted in an impressive array of instrument variations and sample applications, yet the tools and data are largely confined to specialists. It is therefore important that at this junction the IMS community begin to establish IMS as a permanent fixture in life science research thereby making the technology and/or the data approachable by non-mass spectrometrists, leading to further integration into biological and clinical research. In this perspective article, we provide insight into the evolution and current state of IMS and propose some of the directions that IMS could develop in order to stay on course to become one of the most promising new tools in life science research.
Collapse
Affiliation(s)
- Jeramie D. Watrous
- Department of Pharmacology and Department of Chemistry and Biochemistry, University of California, San Diego, La Jolla, California, USA
| | | | - Pieter C. Dorrestein
- Department of Pharmacology and Department of Chemistry and Biochemistry, University of California, San Diego, La Jolla, California, USA
- Skaggs School of Pharmacy and Pharmaceutical Sciences, University of California, San Diego, La Jolla, California, USA
- Center For Marine Biotechnology and Biomedicine, Scripps Institution of Oceanography
| |
Collapse
|
15
|
Chen HK, Chang CK, Wu CC, Huang MC, Wang YS. Synchronized dual-polarity electrospray ionization mass spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2009; 20:2254-2257. [PMID: 19775909 DOI: 10.1016/j.jasms.2009.08.014] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2009] [Revised: 08/18/2009] [Accepted: 08/19/2009] [Indexed: 05/28/2023]
Abstract
This work describes the synchronized dual-polarity (DP) electrospray ionization (ESI) method and demonstrates the first DP ESI mass spectra obtained using two mass spectrometers. Stable double Taylor cones were produced by applying two counter electric voltages with opposite polarities to one electrosprayer. The development of double Taylor cones required higher extraction voltages than conventional ESI, but DP ESI worked effectively at liquid flow rate range three times wider than conventional ESI. Using pure methanol, the emission currents of the two cones were neutralized and no current was drawn from the sprayer. Synchronized DP mass spectra were obtained using electrospray calibrants dissolved in methanol solution of low water content. For bovine insulin with conventional electrospray solution, the gas-assisted electrospray delivered satisfactory sensitivity and stability for routine mass analyses.
Collapse
Affiliation(s)
- Han-Kwang Chen
- Department of Chemistry, Chi Nan University, Nantou, Taiwan, Republic of China
| | | | | | | | | |
Collapse
|
16
|
Liu BH, Lee YT, Wang YS. Incoherent production reactions of positive and negative ions in matrix-assisted laser desorption/ionization. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2009; 20:1078-86. [PMID: 19299167 DOI: 10.1016/j.jasms.2009.02.012] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2008] [Revised: 02/02/2009] [Accepted: 02/03/2009] [Indexed: 05/08/2023]
Abstract
Utilizing synchronized dual-polarity matrix-assisted laser desorption/ionization (MALDI) mass spectrometry, we found good evidence of the incoherent production of positive and negative matrix ions. Using thin, homogeneous 2,5-dehydroxybenzoic acid (DHB) matrix films, positive and negative matrix ions were found to appear at different threshold laser fluences. The presence of molecular matrix ions of single charge polarity suggests that the existence of DHB ion-pairs may not be a prerequisite in MALDI. Photoelectrons induced by the laser excitation may assist the production of negative DHB ions, as shown in experiments conducted with stainless steel and glass substrates. At high laser fluences, the relative yield of positive and negative matrix ions remained constant when homogeneous matrix films were used, but it fluctuated significantly with inhomogeneous crystal morphology. This result is also inconsistent with the hypothesis that matrix ion-pairs are essential primary ions. Evidence from both low and high laser fluences suggests that the productions of positive and negative matrix ions in MALDI may occur via independent pathways.
Collapse
Affiliation(s)
- Bo-Hong Liu
- Department of Chemistry, National Taiwan University, Taipei, Taiwan ROC
| | | | | |
Collapse
|
17
|
Fitch WL, He L, Tu YP, Alexandrova L. Application of polarity switching in the identification of the metabolites of RO9237. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2007; 21:1661-8. [PMID: 17465015 DOI: 10.1002/rcm.3009] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Polarity switching mass spectrometry is an efficient way to collect structural data on drug metabolites. The value of this approach is illustrated with the in vitro metabolism of RO9237. Metabolites are identified by positive and negative electrospray ionization (ESI) full scan mass spectrometry, MS/MS and MS(3) using unlabelled and (14)C-radiolabelled versions of the drug. Comparison of the relative detectability of these metabolites by +ESI and -ESI shows that neither ESI mode is universal. It is advantageous to screen for metabolites using both positive and negative ionization modes. This is especially true for phase II metabolism which tends to make molecules more polar and often more acidic. Identification of phase II metabolites also benefits greatly from MS(3) experiments because the conjugating groups typically are cleaved in MS/MS and information on the core structure is only obtained in MS(3). A special case of phase II metabolism is the generation of glutathione (GSH) conjugates from reactive metabolites. The detection of GSH conjugates also benefits from generating both positive and negative ESI mass spectral data.
Collapse
Affiliation(s)
- William L Fitch
- Drug Metabolism and Pharmacokinetics Department, Roche Palo Alto, LLC, 3431 Hillview Ave., Palo Alto, CA 94304, USA.
| | | | | | | |
Collapse
|