1
|
Bressán I, Martínez OF, Astolfo MA. Bioanalytical validation and clinical application of a liquid chromatography-tandem mass spectrometry method for the quantification of 3-orthomethyldopa, 5-hydroxytryptophan, 5-hydroxyindolacetic acid and homovanillic acid in human cerebrospinal fluid. J Pharm Biomed Anal 2024; 248:116321. [PMID: 38959757 DOI: 10.1016/j.jpba.2024.116321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2024] [Revised: 05/26/2024] [Accepted: 06/20/2024] [Indexed: 07/05/2024]
Abstract
Inherited disorders of monoamine neurotransmitters are a subset of inborn errors of metabolism affecting biochemical pathways of catecholamines, serotonin or their enzymatic cofactors. Usually, their clinical presentation is similar to those of other common neurological syndromes. For this reason, they are frequently under-recognized and misdiagnosed. Because cerebrospinal fluid concentration of catecholamine metabolites (3-orthomethyldopa and homovanillic acid) and serotonin metabolites (5-hydroxytryptophan and 5-hydroxyindolacetic acid) presents a direct correlation with their brain levels, analysis of this group of compounds is critical to reach an accurate diagnosis. Although there are several published liquid chromatography-based bioanalytical methods for the quantification of these compounds, most of them present disadvantages, making their application difficult to implement in routine clinical practice. In this study, a rapid and simple UHPLC-MS/MS method for simultaneous quantification of 3-orthomethyldopa, 5-hydroxytryptophan, 5-hydroxyindolacetic acid and homovanillic acid in human cerebrospinal fluid was validated. All the evaluated performance parameters, including linearity, carryover, accuracy and precision (within and between-day), lower limit of quantitation, recovery, matrix effect and stability under different conditions met the acceptance criteria from international guidelines. Additionally, 10 human cerebrospinal fluid samples collected via lumbar puncture from 10 pediatric patients were quantified using the validated method to assess its clinical application and diagnostic utility for inherited monoamine neurotransmitter metabolism.
Collapse
Affiliation(s)
- Ignacio Bressán
- Laboratory of Chromatography and Mass Spectrometry, Hospital Italiano de Buenos Aires, Tte. Juan Domingo Perón 4190, Buenos Aires C1181ACH, Argentina; Department of Chemistry, Instituto Universitario del Hospital Italiano de Buenos Aires, Potosí 4265, Buenos Aires C1181ACH, Argentina.
| | - Ornella Fracalossi Martínez
- Laboratory of Chromatography and Mass Spectrometry, Hospital Italiano de Buenos Aires, Tte. Juan Domingo Perón 4190, Buenos Aires C1181ACH, Argentina
| | - María Agustina Astolfo
- Laboratory of Chromatography and Mass Spectrometry, Hospital Italiano de Buenos Aires, Tte. Juan Domingo Perón 4190, Buenos Aires C1181ACH, Argentina
| |
Collapse
|
2
|
Oligonucleotides Isolation and Separation—A Review on Adsorbent Selection. Int J Mol Sci 2022; 23:ijms23179546. [PMID: 36076941 PMCID: PMC9455468 DOI: 10.3390/ijms23179546] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 08/18/2022] [Accepted: 08/19/2022] [Indexed: 11/24/2022] Open
Abstract
Oligonucleotides have many important applications, including as primers in polymerase chain reactions and probes for DNA sequencing. They are proposed as a diagnostic and prognostic tool for various diseases and therapeutics in antisense therapy. Accordingly, it is necessary to develop liquid chromatography and solid phase extraction methods to separate oligonucleotides and isolate them from biological samples. Many reviews have been written about the determination of these compounds using the separation technique or sample preparation for their isolation. However, presumably, there are no articles that critically review the adsorbents used in liquid chromatography or solid phase extraction. The present publication reviews the literature from the last twenty years related to supports (silica, polymers, magnetic nanoparticles) and their modifications. The discussed issues concern reversed phase (alkyl, aromatic, cholesterol, mixed ligands), ion-exchange (strong and weak ones), polar (silica, polyhydroxy, amide, zwitterionic), and oligonucleotide-based adsorbents.
Collapse
|
3
|
Controllable fabrication of pico/femtoliter pipette sampling probes and visual sample volume determination. Talanta 2020; 218:121096. [DOI: 10.1016/j.talanta.2020.121096] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2020] [Revised: 04/25/2020] [Accepted: 04/27/2020] [Indexed: 12/11/2022]
|
4
|
Abstract
The chemistry of DNA and its repair selectivity control the influence of genomic oxidative stress on the development of serious disorders such as cancer and heart diseases. DNA is oxidized by endogenous reactive oxygen species (ROS) in vivo or in vitro as a result of high energy radiation, non-radiative metabolic processes, and other consequences of oxidative stress. Some oxidations of DNA and tumor suppressor gene p53 are thought to be mutagenic when not repaired. For example, site-specific oxidations of p53 tumor suppressor gene may lead to cancer-related mutations at the oxidation site codon. This review summarizes the research on the primary products of the most easily oxidized nucleobase guanine (G) when different oxidation methods are used. Guanine is by far the most oxidized DNA base. The primary initial oxidation product of guanine for most, but not all, pathways is 8-oxoguanine (8-oxoG). With an oxidation potential much lower than G, 8-oxoG is readily susceptible to further oxidation, and the products often depend on the oxidants. Specific products may control the types of subsequent mutations, but mediated by gene repair success. Site-specific oxidations of p53 tumor suppressor gene have been reported at known mutation hot spots, and the codon sites also depend on the type of oxidants. Modern methodologies using LC-MS/MS for codon specific detection and identification of oxidation sites are summarized. Future work aimed at understanding DNA oxidation in nucleosomes and interactions between DNA damage and repair is needed to provide a better picture of how cancer-related mutations arise.
Collapse
Affiliation(s)
- Di Jiang
- Department of ChemistryUniversity of ConnecticutStorrsCT 06269United States
| | - James F. Rusling
- Department of ChemistryUniversity of ConnecticutStorrsCT 06269United States
- Department of SurgeryNeag Cancer Center, UConn HealthFarmingtonCT 06032United States
- Institute of Material ScienceUniversity of ConnecticutStorrsCT 06269United States
- School of ChemistryNational University of Ireland at GalwayIreland
| |
Collapse
|
5
|
Recent technical and biological development in the analysis of biomarker N-deoxyguanosine-C8-4-aminobiphenyl. J Chromatogr B Analyt Technol Biomed Life Sci 2018; 1087-1088:49-60. [PMID: 29709872 DOI: 10.1016/j.jchromb.2018.04.041] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2018] [Revised: 04/05/2018] [Accepted: 04/23/2018] [Indexed: 12/12/2022]
Abstract
4-Aminobiphenyl (4-ABP) which is primarily formed during tobacco combustion and overheated meat is a major carcinogen responsible for various cancers. Its adducted form, N-deoxyguanosine-C8-4-aminobiphenyl (dG-C8-4-ABP), has long been employed as a biomarker for assessment of the risk for cancer. In this review, the metabolism and carcinogenisity of 4-ABP will be discussed, followed by a discussion of the current common approaches of analyzing dG-C8-4-ABP. The major part of this review will be on the history and recent development of key methods for detection and quantitation of dG-C8-4-ABP in complex biological samples and their biological applications, from the traditional 2P-postlabelling and immunoassay methods to modern liquid chromatography-mass spectrometry (LC-MS) with the latter as the focus. Many vital biological discoveries based on dG-C8-4-ABP have been published by using the nanoLC-MS with column switching platform in our laboratory, which has also been adopted and further improved by many other researchers. We hope this review can provide a perspective of the challenges that had to be addressed in reaching our present goals and possibly bring new ideas for those who are still working on the frontline of DNA adducts area.
Collapse
|
6
|
A review of nanoscale LC-ESI for metabolomics and its potential to enhance the metabolome coverage. Talanta 2018; 182:380-390. [PMID: 29501168 DOI: 10.1016/j.talanta.2018.01.084] [Citation(s) in RCA: 65] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2017] [Revised: 01/29/2018] [Accepted: 01/30/2018] [Indexed: 12/22/2022]
Abstract
Liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) platforms are widely used to perform high throughput untargeted profiling of biological samples for metabolomics-based approaches. However, these LC-ESI platforms usually favour the detection of metabolites present at relatively high concentrations because of analytical limitations such as ion suppression, thus reducing overall sensitivity. To counter this issue of sensitivity, the latest in terms of analytical platforms can be adopted to enable a greater portion of the metabolome to be analysed in a single analytical run. Here, nanoflow liquid chromatography-nanoelectrospray ionisation (nLC-nESI), which has previously been utilised successfully in proteomics, is explored for use in metabolomic and exposomic research. As a discovery based field, the markedly increased sensitivity of these nLC-nESI platforms offer the potential to uncover the roles played by low abundant signalling metabolites (e.g. steroids, eicosanoids) in health and disease studies, and would also enable an improvement in the detection of xenobiotics present at trace levels in biological matrices to better characterise the chemical exposome. This review aims to give an insight into the advantages associated with nLC-nESI for metabolomics-based approaches. Initially we detail the source of improved sensitivity prior to reviewing the available approaches to achieving nanoflow rates and nanospray ionisation for metabolomics. The robustness of nLC-nESI platforms was then assessed using the literature available from a metabolomic viewpoint. We also discuss the challenging point of sample preparation which needs to be addressed to fully enjoy the benefits of these nLC-nESI platforms. Finally, we assess metabolomic analysis utilising nano scale platforms and look ahead to the future of metabolomics using these new highly sensitive platforms.
Collapse
|
7
|
Blum BC, Mousavi F, Emili A. Single-platform ‘multi-omic’ profiling: unified mass spectrometry and computational workflows for integrative proteomics–metabolomics analysis. Mol Omics 2018; 14:307-319. [DOI: 10.1039/c8mo00136g] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Advances in instrumentation and analysis tools are permitting evermore comprehensive interrogation of diverse biomolecules and allowing investigators to move from linear signaling cascades to network models, which more accurately reflect the molecular basis of biological systems and processes.
Collapse
Affiliation(s)
- Benjamin C. Blum
- Center for Network Systems Biology
- Boston University School of Medicine
- Boston
- USA
- Department of Biochemistry
| | - Fatemeh Mousavi
- Donnelly Centre
- Department of Molecular Genetics
- University of Toronto
- Toronto
- Canada
| | - Andrew Emili
- Center for Network Systems Biology
- Boston University School of Medicine
- Boston
- USA
- Department of Biochemistry
| |
Collapse
|
8
|
Jiang D, Malla S, Fu YJ, Choudhary D, Rusling JF. Direct LC-MS/MS Detection of Guanine Oxidations in Exon 7 of the p53 Tumor Suppressor Gene. Anal Chem 2017; 89:12872-12879. [PMID: 29116749 PMCID: PMC5777150 DOI: 10.1021/acs.analchem.7b03487] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Oxidation of DNA by reactive oxygen species (ROS) yields 8-oxo-7,8-dihydroguanosine (8-oxodG) as primary oxidation product, which can lead to downstream G to T transversion mutations. DNA mutations are nonrandom, and mutations at specific codons are associated with specific cancers, as widely documented for the p53 tumor suppressor gene. Here, we present the first direct LC-MS/MS study (without isotopic labeling or hydrolysis) of primary oxidation sites of p53 exon 7. We oxidized a 32 base pair (bp) double-stranded (ds) oligonucleotide representing exon 7 of the p53 gene. Oxidized oligonucleotides were cut by a restriction endonuclease to provide small strands and enable positions and amounts of 8-oxodG to be determined directly by LC-MS/MS. Oxidation sites on the oligonucleotide generated by two oxidants, catechol/Cu2+/NADPH and Fenton's reagent, were located and compared. Guanines in codons 243, 244, 245, and 248 were most frequently oxidized by catechol/Cu2+/NADPH with relative oxidation of 5.6, 7.2, 2.6, and 10.7%, respectively. Fenton's reagent oxidations were more specific for guanines in codons 243 (20.3%) and 248 (10.4%). Modeling of docking of oxidizing species on the ds-oligonucleotide were consistent with the experimental codon oxidation sites. Significantly, codons 244 and 248 are mutational "hotspots" in nonsmall cell and small cell lung cancers, supporting a possible role of oxidation in p53 mutations leading to lung cancer.
Collapse
Affiliation(s)
- Di Jiang
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Spundana Malla
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
| | - You-jun Fu
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Dharamainder Choudhary
- Department of Surgery and Neag Cancer Center, UConn Health, Farmington, Connecticut 06032, United States
| | - James F. Rusling
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
- Department of Surgery and Neag Cancer Center, UConn Health, Farmington, Connecticut 06032, United States
- Institute of Material Science, University of Connecticut, Storrs, Connecticut 06269, United States
- School of Chemistry, National University of Ireland at Galway, Galway H91 TK33, Ireland
| |
Collapse
|
9
|
Eeltink S, Wouters S, Dores-Sousa JL, Svec F. Advances in organic polymer-based monolithic column technology for high-resolution liquid chromatography-mass spectrometry profiling of antibodies, intact proteins, oligonucleotides, and peptides. J Chromatogr A 2017; 1498:8-21. [PMID: 28069168 DOI: 10.1016/j.chroma.2017.01.002] [Citation(s) in RCA: 63] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2016] [Revised: 11/22/2016] [Accepted: 01/02/2017] [Indexed: 11/27/2022]
Abstract
This review focuses on the preparation of organic polymer-based monolithic stationary phases and their application in the separation of biomolecules, including antibodies, intact proteins and protein isoforms, oligonucleotides, and protein digests. Column and material properties, and the optimization of the macropore structure towards kinetic performance are also discussed. State-of-the-art liquid chromatography-mass spectrometry biomolecule separations are reviewed and practical aspects such as ion-pairing agent selection and carryover are presented. Finally, advances in comprehensive two-dimensional LC separations using monolithic columns, in particular ion-exchange×reversed-phase and reversed-phase×reversed-phase LC separations conducted at high and low pH, are shown.
Collapse
Affiliation(s)
- Sebastiaan Eeltink
- Vrije Universiteit Brussel, Department of Chemical Engineering, Pleinlaan 2, B-1050 Brussels, Belgium.
| | - Sam Wouters
- Vrije Universiteit Brussel, Department of Chemical Engineering, Pleinlaan 2, B-1050 Brussels, Belgium
| | - José Luís Dores-Sousa
- Vrije Universiteit Brussel, Department of Chemical Engineering, Pleinlaan 2, B-1050 Brussels, Belgium
| | - Frantisek Svec
- Beijing Advanced Innovation Center for Soft Matter Science and Engineering, Beijing University of Chemical Technology, Beijing, China
| |
Collapse
|
10
|
Zhu X, Liang Y, Weng Y, Chen Y, Jiang H, Zhang L, Liang Z, Zhang Y. Gold-Coated Nanoelectrospray Emitters Fabricated by Gravity-Assisted Etching Self-Termination and Electroless Deposition. Anal Chem 2016; 88:11347-11351. [DOI: 10.1021/acs.analchem.6b03422] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Affiliation(s)
- Xudong Zhu
- Key Laboratory of Separation Science for Analytical Chemistry, National Chromatographic R & A Center, Dalian Institute of Chemical Physics, Chinese Academy of Science, Dalian, 116023, China
- University of Chinese Academy of Sciences, Beijing 100039, China
| | - Yu Liang
- Key Laboratory of Separation Science for Analytical Chemistry, National Chromatographic R & A Center, Dalian Institute of Chemical Physics, Chinese Academy of Science, Dalian, 116023, China
| | - Yejing Weng
- Key Laboratory of Separation Science for Analytical Chemistry, National Chromatographic R & A Center, Dalian Institute of Chemical Physics, Chinese Academy of Science, Dalian, 116023, China
- University of Chinese Academy of Sciences, Beijing 100039, China
| | - Yuanbo Chen
- Key Laboratory of Separation Science for Analytical Chemistry, National Chromatographic R & A Center, Dalian Institute of Chemical Physics, Chinese Academy of Science, Dalian, 116023, China
- University of Chinese Academy of Sciences, Beijing 100039, China
| | - Hao Jiang
- Key Laboratory of Separation Science for Analytical Chemistry, National Chromatographic R & A Center, Dalian Institute of Chemical Physics, Chinese Academy of Science, Dalian, 116023, China
- University of Chinese Academy of Sciences, Beijing 100039, China
| | - Lihua Zhang
- Key Laboratory of Separation Science for Analytical Chemistry, National Chromatographic R & A Center, Dalian Institute of Chemical Physics, Chinese Academy of Science, Dalian, 116023, China
| | - Zhen Liang
- Key Laboratory of Separation Science for Analytical Chemistry, National Chromatographic R & A Center, Dalian Institute of Chemical Physics, Chinese Academy of Science, Dalian, 116023, China
| | - Yukui Zhang
- Key Laboratory of Separation Science for Analytical Chemistry, National Chromatographic R & A Center, Dalian Institute of Chemical Physics, Chinese Academy of Science, Dalian, 116023, China
| |
Collapse
|
11
|
Mikulášek K, Jaroň KS, Kulhánek P, Bittová M, Havliš J. Sequence-dependent separation of trinucleotides by ion-interaction reversed-phase liquid chromatography-A structure-retention study assisted by soft-modelling and molecular dynamics. J Chromatogr A 2016; 1469:88-95. [PMID: 27692640 DOI: 10.1016/j.chroma.2016.09.060] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2016] [Revised: 09/22/2016] [Accepted: 09/24/2016] [Indexed: 10/21/2022]
Abstract
We studied sequence-dependent retention properties of synthetic 5'-terminal phosphate absent trinucleotides containing adenine, guanine and thymine through reversed-phase liquid chromatography (RPLC) and QSRR modelling. We investigated the influence of separation conditions, namely mobile phase composition (ion interaction agent content, pH and organic constituent content), on sequence-dependent separation by means of ion-interaction RPLC (II-RPLC) using two types of models: experimental design-artificial neural networks (ED-ANN), and linear regression based on molecular dynamics data. The aim was to determine those properties of the above-mentioned analytes responsible for the retention dependence of the sequence. Our results show that there is a deterministic relation between sequence and II-RPLC retention properties of the studied trinucleotides. Further, we can conclude that the higher the content of ion-interaction agent in the mobile phase, the more prominent these properties are. We also show that if we approximate the polar component of solvation energy in QSRR by the electrostatic work in transferring molecules from vacuum to water, and the non-polar component by the solvent accessible surface area, these parameters best describe the retention properties of trinucleotides. There are some exceptions to this finding, namely sequences 5'-NAN-3', 5'-ANN-3', 5'-TGN-3', 5'-NTA-3'and 5'-NGA-3' (N stands for generic nucleotide). Their role is still unknown, but since linear regression including these specific constellations showed a higher observable variance coverage than the model with only the basic descriptors, we may assume that solvent-analyte interactions are responsible for the exceptional behaviour of 5'-NAN-3' & 5'-ANN-3' trinucleotides and some intramolecular interactions of neighbouring nucleobases for 5'-TGN-3', 5'-NTA-3'and 5'-NGA-3' trinucleotides.
Collapse
Affiliation(s)
- Kamil Mikulášek
- Masaryk University, Faculty of Science, Department of Chemistry, Kamenice 5, 62500 Brno, Czech Republic; Masaryk University, CEITEC - Central European Institute of Technology, Kamenice 5, 62500 Brno, Czech Republic
| | - Kamil S Jaroň
- Academy of Sciences of the Czech Republic, Institute of Vertebrate Biology, Květná 8, 603 65 Brno, Czech Republic
| | - Petr Kulhánek
- Masaryk University, CEITEC - Central European Institute of Technology, Kamenice 5, 62500 Brno, Czech Republic; Masaryk University, Faculty of Science, National Centre of Biomolecular Research, Kamenice 5, 62500 Brno, Czech Republic
| | - Miroslava Bittová
- Masaryk University, Faculty of Science, Department of Chemistry, Kamenice 5, 62500 Brno, Czech Republic
| | - Jan Havliš
- Masaryk University, CEITEC - Central European Institute of Technology, Kamenice 5, 62500 Brno, Czech Republic; Masaryk University, Faculty of Science, National Centre of Biomolecular Research, Kamenice 5, 62500 Brno, Czech Republic.
| |
Collapse
|
12
|
Close ED, Nwokeoji AO, Milton D, Cook K, Hindocha DM, Hook EC, Wood H, Dickman MJ. Nucleic acid separations using superficially porous silica particles. J Chromatogr A 2016; 1440:135-144. [PMID: 26948761 PMCID: PMC4801196 DOI: 10.1016/j.chroma.2016.02.057] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2015] [Revised: 02/17/2016] [Accepted: 02/19/2016] [Indexed: 01/31/2023]
Abstract
Ion pair reverse-phase liquid chromatography has been widely employed for nucleic acid separations. A wide range of alternative stationary phases have been utilised in conjunction with ion pair reverse-phase chromatography, including totally porous particles, non-porous particles, macroporous particles and monolithic stationary phases. In this study we have utilised superficially porous silica particles in conjunction with ion pair reverse-phase liquid chromatography for the analysis of nucleic acids. We have investigated a range of different pore-sizes and phases for the analysis of a diverse range of nucleic acids including oligonucleotides, oligoribonucleotides, phosphorothioate oligonucleotides and high molecular weight dsDNA and RNA. The pore size of the superficially porous silica particles was shown to significantly affect the resolution of the nucleic acids. Optimum separations of small oligonucleotides such as those generated in RNase mapping experiments were obtained with 80Å pore sizes and can readily be interfaced with mass spectrometry analysis. Improved resolution of larger oligonucleotides (>19mers) was observed with pore sizes of 150Å. The optimum resolution for larger dsDNA/RNA molecules was achieved using superficially porous silica particles with pore sizes of 400Å. Furthermore, we have utilised 150Å pore size solid-core particles to separate typical impurities of a fully phosphorothioated oligonucleotide, which are often generated in the synthesis of this important class of therapeutic oligonucleotide.
Collapse
Affiliation(s)
- Elizabeth D Close
- Department of Chemical and Biological Engineering, ChELSI Institute, University of Sheffield, Mappin Street, Sheffield S1 3JD, UK
| | - Alison O Nwokeoji
- Department of Chemical and Biological Engineering, ChELSI Institute, University of Sheffield, Mappin Street, Sheffield S1 3JD, UK
| | - Dafydd Milton
- Thermo Fisher Scientific, Stafford House, Boundary Way, Hemel Hempstead HP2 7GE, UK
| | - Ken Cook
- Thermo Fisher Scientific, Stafford House, Boundary Way, Hemel Hempstead HP2 7GE, UK
| | - Darsha M Hindocha
- GlaxoSmithKline, Medicines Research Centre, Gunnels Wood Road, Stevenage, Hertfordshire SG1 2NY, UK
| | - Elliot C Hook
- GlaxoSmithKline, Medicines Research Centre, Gunnels Wood Road, Stevenage, Hertfordshire SG1 2NY, UK
| | - Helen Wood
- GlaxoSmithKline, Medicines Research Centre, Gunnels Wood Road, Stevenage, Hertfordshire SG1 2NY, UK
| | - Mark J Dickman
- Department of Chemical and Biological Engineering, ChELSI Institute, University of Sheffield, Mappin Street, Sheffield S1 3JD, UK.
| |
Collapse
|
13
|
Liu S, Wang Y. Mass spectrometry for the assessment of the occurrence and biological consequences of DNA adducts. Chem Soc Rev 2015; 44:7829-54. [PMID: 26204249 PMCID: PMC4787602 DOI: 10.1039/c5cs00316d] [Citation(s) in RCA: 102] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Exogenous and endogenous sources of chemical species can react, directly or after metabolic activation, with DNA to yield DNA adducts. If not repaired, DNA adducts may compromise cellular functions by blocking DNA replication and/or inducing mutations. Unambiguous identification of the structures and accurate measurements of the levels of DNA adducts in cellular and tissue DNA constitute the first and important step towards understanding the biological consequences of these adducts. The advances in mass spectrometry (MS) instrumentation in the past 2-3 decades have rendered MS an important tool for structure elucidation, quantification, and revelation of the biological consequences of DNA adducts. In this review, we summarized the development of MS techniques on these fronts for DNA adduct analysis. We placed our emphasis of discussion on sample preparation, the combination of MS with gas chromatography- or liquid chromatography (LC)-based separation techniques for the quantitative measurement of DNA adducts, and the use of LC-MS along with molecular biology tools for understanding the human health consequences of DNA adducts. The applications of mass spectrometry-based DNA adduct analysis for predicting the therapeutic outcome of anti-cancer agents, for monitoring the human exposure to endogenous and environmental genotoxic agents, and for DNA repair studies were also discussed.
Collapse
Affiliation(s)
- Shuo Liu
- Environmental Toxicology Graduate Program, University of California, Riverside, California, USA
| | - Yinsheng Wang
- Environmental Toxicology Graduate Program, University of California, Riverside, California, USA and Department of Chemistry, University of California, Riverside, CA 92521-0403, USA.
| |
Collapse
|
14
|
Malla S, Kadimisetty K, Fu YJ, Choudhary D, Jansson I, Schenkman JB, Rusling JF. CHEMICAL SELECTIVITY OF NUCLEOBASE ADDUCTION RELATIVE TO IN VIVO MUTATION SITES ON EXON 7 FRAGMENT OF P53 TUMOR SUPPRESSOR GENE. Chem Sci 2015; 6:5554-5563. [PMID: 26417421 PMCID: PMC4583204 DOI: 10.1039/c5sc01403d] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2015] [Accepted: 06/24/2015] [Indexed: 01/03/2023] Open
Abstract
Damage to p53 tumor suppressor gene is found in half of all human cancers. Databases integrating studies of large numbers of tumors and cancer cell cultures show that mutation sites of specific p53 codons are correlated with specific types of cancers. If the most frequently damaged p53 codons in vivo correlate with the most frequent chemical damage sites in vitro, predictions of organ-specific cancer risks might result. Herein, we describe LC-MS/MS methodology to reveal codons with metabolite-adducted nucleobases by LC-MS/MS for oligonucleotides longer than 20 base pairs. Specifically, we used a known carcinogen, benzo[a]pyrene-7,8-dihydrodiol-9,10-epoxide (BPDE) to determine the most frequently adducted nucleobases within codons. We used a known sequence of 32 base pairs (bp) representing part of p53 exon 7 with 5 possible reactive hot spots. This is the first nucleobase reactivity study of a double stranded DNA p53 fragment featuring more than 20 base pairs with multiple reactive sites. We reacted the 32 bp fragment with benzo[a]pyrene metabolite BPDE that undergoes nucleophilic substitution by DNA bases. Liquid chromatography-mass spectrometry (LC-MS/MS) was used for sequencing of oligonucleotide products from the reacted 32 bp fragment after fragmentation by a restriction endonuclease. Analysis of the adducted p53 fragment compared with unreacted fragment revealed guanines of codons 248 and 244 as most frequently targeted, which are also mutated with high frequency in human tumors. Codon 248 is mutated in non-small cell and small cell lung, head and neck, colorectal and skin cancer, while codon 244 is mutated in small cell lung cancer, all of which involve possible BDPE exposure. Results suggest the utility of this approach for screening of adducted p53 gene by drugs and environmental chemicals to predict risks for organ specific cancers.
Collapse
Affiliation(s)
- Spundana Malla
- Department of Chemistry , University of Connecticut , Storrs , CT 06269 , USA .
| | - Karteek Kadimisetty
- Department of Chemistry , University of Connecticut , Storrs , CT 06269 , USA .
| | - You-Jun Fu
- Department of Chemistry , University of Connecticut , Storrs , CT 06269 , USA .
| | - Dharamainder Choudhary
- Department of Surgery , University of Connecticut Health Center , Farmington , CT 06032 , USA
| | - Ingela Jansson
- Department of Cell Biology , University of Connecticut Health Center , Farmington , CT 06032 , USA
| | - John B. Schenkman
- Department of Cell Biology , University of Connecticut Health Center , Farmington , CT 06032 , USA
| | - James F. Rusling
- Department of Chemistry , University of Connecticut , Storrs , CT 06269 , USA .
- Department of Cell Biology , University of Connecticut Health Center , Farmington , CT 06032 , USA
- Institute of Material Science , University of Connecticut , Storrs , CT 06269 , USA
- School of Chemistry , National University of Ireland at Galway , Ireland
| |
Collapse
|
15
|
Li S, Limbach PA. Identification of RNA sequence isomer by isotope labeling and LC-MS/MS. JOURNAL OF MASS SPECTROMETRY : JMS 2014; 49:1191-1198. [PMID: 25395135 DOI: 10.1002/jms.3449] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/20/2014] [Revised: 07/22/2014] [Accepted: 07/23/2014] [Indexed: 06/04/2023]
Abstract
Recently, we developed a method for modified ribonucleic acid (RNA) analysis based on the comparative analysis of RNA digests (CARD). Within this CARD approach, sequence or modification differences between two samples are identified through differential isotopic labeling of two samples. Components present in both samples will each be labeled, yielding doublets in the CARD mass spectrum. Components unique to only one sample should be detected as singlets. A limitation of the prior singlet identification strategy occurs when the two samples contain components of unique sequence but identical base composition. At the first stage of mass spectrometry, these sequence isomers cannot be differentiated and would appear as doublets rather than singlets. However, underlying sequence differences should be detectable by collision-induced dissociation tandem mass spectrometry (CID MS/MS), as y-type product ions will retain the original enzymatically incorporated isotope label. Here, we determine appropriate instrumental conditions that enable CID MS/MS of isotopically labeled ribonuclease T1 (RNase T1) digestion products such that the original isotope label is maintained in the product ion mass spectrum. Next, we demonstrate how y-type product ions can be used to differentiate singlets and doublets from isomer sequences. We were then able to extend the utility of this approach by using CID MS/MS for the confirmation of an expected RNase T1 digestion product within the CARD analysis of an Escherichia coli mutant strain even in the presence of interfering and overlapping digestion products from other transfer RNAs.
Collapse
Affiliation(s)
- Siwei Li
- Rieveschl Laboratories for Mass Spectrometry, Department of Chemistry, University of Cincinnati, PO Box 210172, Cincinnati, OH, 45221-0172, USA
| | | |
Collapse
|
16
|
Grova N, Salquèbre G, Hardy EM, Schroeder H, Appenzeller BMR. Tetrahydroxylated-benzo[a]pyrene isomer analysis after hydrolysis of DNA-adducts isolated from rat and human white blood cells. J Chromatogr A 2014; 1364:183-91. [PMID: 25239702 DOI: 10.1016/j.chroma.2014.08.082] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2014] [Revised: 08/22/2014] [Accepted: 08/26/2014] [Indexed: 11/27/2022]
Abstract
Since exposure to benzo[a]pyrene is suspected to be associated with several health issues, significant efforts have been made to develop efficient strategies for the assessment of human exposure to this ubiquitous compound. In this context, a method was developed for the analysis of four tetrahydroxylated-benzo[a]pyrene isomers resulting from the hydrolysis of their respective diol-epoxide precursors which are involved in DNA-adduct formation. The analytical sensitivity necessary to reach environmental levels of concentration was obtained by using gas chromatography-tandem mass spectrometry. The recovery determined at the four concentration levels were estimated in average at 83% for benzo[a]pyrene-r-7,t-8,t-9,c-10-tetrahydrotetrol(±), 29% for benzo[a]pyrene-r-7,t-8,t-9,t-10-tetrahydrotetrol(±), and 82% for benzo[a]pyrene-r-7,t-8,C-9,c-10-tetrahydrotetrol(±). The coefficient of determination of the calibration curve was above 0.997 for all the analytes investigated and the limit of quantification ranged from 0.5 to 2 adduct/10(8) nucleotides. The precision was between 5.3% and 22.3%. The suitability of the method was firstly evaluated by the analysis of DNA isolated from white blood cells of rats submitted after controlled exposure to benzo[a]pyrene. The four targeted tetra-OH-benzo[a]pyrenes as well as two unknown isomers were detected in all the treated animals. Benzo[a]pyrene-r-7,t-8,c-9,c-10-tetrahydrotetrol(±) appeared as the most abundant isomer in both treated and control animals followed by benzo[a]pyrene-r-7,t-8,t-9,c-10-tetrahydrotetrol(±). The method was afterwards applied to the analysis of DNA isolated from white blood cells of human volunteers. The results confirmed that this method was sufficiently sensitive to monitor environmental levels of exposure since all the specimens analyzed were above the limit of quantification for benzo[a]pyrene-r-7,t-8,t-9,c-10-tetrahydrotetrol(±) and two of them were positive for benzo[a]pyrene-r-7,t-8,c-9,c-10-tetrahydrotetrol(±), thereby highlighting interspecies differences in the nature of the tetrahydroxylated-benzo[a]pyrene isomers formed. This study confirms the necessity to focus on all the tetrahydroxylated-benzo[a]pyrene isomers, which could be indicators of benzo[a]pyrene-associated toxicity related to an individual's own metabolism, rather than limit to a single form.
Collapse
Affiliation(s)
- Nathalie Grova
- Laboratory of Analytical Human Biomonitoring, CRP-Santé, Luxembourg, 1511, Luxembourg France.
| | - Guillaume Salquèbre
- Laboratory of Analytical Human Biomonitoring, CRP-Santé, Luxembourg, 1511, Luxembourg France
| | - Emilie M Hardy
- Laboratory of Analytical Human Biomonitoring, CRP-Santé, Luxembourg, 1511, Luxembourg France
| | - Henri Schroeder
- Unité de Recherche Animal et Fonctionnalités des Produits Animaux, INRA UC340, 54505, Vandoeuvre-lès-Nancy, France
| | - Brice M R Appenzeller
- Laboratory of Analytical Human Biomonitoring, CRP-Santé, Luxembourg, 1511, Luxembourg France
| |
Collapse
|
17
|
Sharma VK, Xiong W, Glick J, Vouros P. Determination of site selectivity of different carcinogens for preferential mutational hot spots in oligonucleotide fragments by ion-pair reversed-phase nano liquid chromatography tandem mass spectrometry. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2014; 20:63-72. [PMID: 24881456 DOI: 10.1255/ejms.1268] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Ion-pair reversed-phase nano liquid chromatography coupled with nanospray ion trap mass spectrometry was used to investigate site selectivity of the known carcinogens N-acetoxy-2-acetylaminofluorene, N-hydroxy-4-aminobiphenyl and (+/-)-anti-benzo[a]pyrene diol epoxide with the synthetic double-strand 14-mer long oligonucleotide fragment of the p53 gene containing two mutational hot-spot codons (5'-P-ACC155 CGC156 GTC157 CGC158 GC/5'-GCG CGG ACG CGG GT). The investigation was performed using a monolithic polystyrene divinylbenzene capillary column and triethylammonium bicarbonate as an ion-pair reagent. The exact location of the carcinogen on the modified oligonucleotide backbone was determined using characteristic collision-induced dissociation fragmentation patterns obtained under negative-ion mode ionization. In all these cases, the adducted, isomeric oligonucleotides formed were chromatographically resolved and structural identification was performed without any prior deoxyribonucleic acid cleavage or hydrolysis. The knowledge of the site specificity of a carcinogen, especially at purported mutational hot spots, is of paramount importance (1) in establishing the identity of biomarkers for an early risk assessment of the formed DNA adducts, (2) developing repair mechanisms for the formed carcinogen adducted DNA, and (3) understanding the nature of the covalent bond formed and mapping the frequency of the adduction process.
Collapse
|
18
|
Shi S, Zhao B, Yagnik G, Zhou F. An interface for sensitive analysis of monoamine neurotransmitters by ion-pair chromatography-electrospray ionization-mass spectrometry with continuous online elimination of ion-pair reagents. Anal Chem 2013; 85:6598-602. [PMID: 23767971 PMCID: PMC3780787 DOI: 10.1021/ac401396j] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
A challenge in coupling ion-pair chromatography (IPC) online with electrospray ionization-mass spectrometry (ESI-MS) is that the nonvolatile ion-pair reagent (e.g., alkyl sulfate for amines or tetrabutylammonium for carboxylic acids) in the mobile phase suppresses the ESI-MS signals in the gas phase and their accumulation can clog the MS sampling interface. Consequently, IPC-ESI-MS is conducted either with a volatile ion-pair reagent, which could compromise the analyte separation efficiency, or with a downstream ion-exchange column to rid the ion-pair reagents of the mobile phase. In the latter approach, the limited capacity of ion-exchange columns requires frequent off-line column regeneration, which affects the separation throughput and prohibits long separations from being performed. A dual-valve, dual-ion exchange column interface of IPC-ESI-MS is designed for undisrupted separations and simultaneous column regeneration. Owing to the efficacy in removing the ion-pair reagent, the detection of eluents of monoamine neurotransmitters by an ion trap MS results in the limits of detection of 0.03 μM for dopamine or DA and 0.01 μM for 5-hydroxytryptamine or 5-HT. These values are lower than those obtained with ion trap MS of similar sensitivity when combined with the use of specialized chromatographic columns or sample preconcentration. Excellent reproducibility was attained with repeatedly regenerated ion-exchange columns (RSD = 4-6%) for an extended period of time (RSD < 6% for 6 days). DA and 5-HT in rat straital extracts were analyzed, and our data demonstrate that interferences inherent in the tissues and the ion-pair reagent have been successfully eliminated. This simple interface should be readily amenable to the separation and MS analysis of other types of polar compounds in complex sample media.
Collapse
Affiliation(s)
- Shuyun Shi
- Department of Chemistry and Biochemistry, California State University, Los Angeles, Los Angeles, California 90032
- College of Chemistry and Chemical Engineering, Central South University, Changsha, Hunan, P. R. China 410083
| | - Binqing Zhao
- Department of Chemistry and Biochemistry, California State University, Los Angeles, Los Angeles, California 90032
| | - Gargey Yagnik
- Department of Chemistry and Biochemistry, California State University, Los Angeles, Los Angeles, California 90032
| | - Feimeng Zhou
- Department of Chemistry and Biochemistry, California State University, Los Angeles, Los Angeles, California 90032
| |
Collapse
|
19
|
Bittová M, Havliš J, Fuksová H, Vrbková B, Trnková L. Toward reading the sequence of short oligonucleotides from their retention factors obtained by means of hydrophilic interaction chromatography and ion-interaction reversed-phase liquid chromatography. J Sep Sci 2013; 35:3227-34. [PMID: 23175142 DOI: 10.1002/jssc.201200482] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2012] [Revised: 08/17/2012] [Accepted: 08/17/2012] [Indexed: 11/08/2022]
Abstract
Retention characteristics of selected synthetic 5'-terminal phosphate absent penta-nucleotides containing adenine, guanine, and thymine were studied in relation to their sequence by hydrophilic interaction chromatography and ion-interaction reversed-phase liquid chromatography. The organic solvent content, pH, and buffer concentration in mobile phases were evaluated as influential separation conditions. Data demonstrate that both compared chromatographic modes can be used to separate synthetic penta-nucleotides according to their nucleotide composition. Moreover, reversed-phase liquid chromatography allows separation according to their sequence. We have found a simple linear additive model to describe the retention order in both separation modes in regard to their sequence. In hydrophilic interaction chromatography, the retention behavior is controlled primarily by the hydrophilicity of involved nucleotides and minimally by their sequence position. For reversed-phase liquid chromatography, the nucleotide hydrophobicity plays an important role in their retention properties and the influence of their location in sequence on the retention increases toward the center and decreases toward the termini. Our results show that the penta-nucleotide sequence, and thus its spatial arrangement induced by the surrounding environment, is highly related to the retention properties, so it may be hypothetically used to read the sequence from the retention properties acquired under particular separation conditions.
Collapse
Affiliation(s)
- Miroslava Bittová
- Faculty of Science, Department of Chemistry, Masaryk University, Brno, Czech Republic
| | | | | | | | | |
Collapse
|
20
|
Affiliation(s)
- Natalia Tretyakova
- Department of Medicinal Chemistry, University of Minnesota, Minneapolis, Minnesota 55455, USA.
| | | | | |
Collapse
|
21
|
Klaene JJ, Sharma VK, Glick J, Vouros P. The analysis of DNA adducts: the transition from (32)P-postlabeling to mass spectrometry. Cancer Lett 2012; 334:10-9. [PMID: 22960573 DOI: 10.1016/j.canlet.2012.08.007] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2012] [Revised: 07/20/2012] [Accepted: 08/07/2012] [Indexed: 10/27/2022]
Abstract
The technique of (32)P-postlabeling, which was introduced in 1982 for the analysis of DNA adducts, has long been the method of choice for in vivo studies because of its high sensitivity as it requires only <10μg DNA to achieve the detection of 1 adduct in 10(10) normal bases. (32)P-postlabeling has therefore been utilized in numerous human and animal studies of DNA adduct formation. Like all techniques (32)P-postlabeling does have several disadvantages including the use of radioactive phosphorus, lack of internal standards, and perhaps most significantly does not provide any structural information for positive identification of unknown adducts, a shortcoming that could significantly hamper progress in the field. Structural methods have since been developed to allow for positive identification of DNA adducts, but to this day, the same level of sensitivity and low sample requirements provided by (32)P-postlabeling have not been matched. In this mini review we will discuss the (32)P-postlabeling method and chronicle the transition to mass spectrometry via the hyphenation of gas chromatography, capillary electrophoresis, and ultimately liquid chromatography which, some 30years later, is only just starting to approach the sensitivity and low sample requirements of (32)P-postlabeling. This paper focuses on the detection of bulky carcinogen-DNA adducts, with no mention of oxidative damage or small alkylating agents. This is because the (32)P-postlabeling assay is most compatible with bulky DNA adducts. This will also allow a more comprehensive focus on a subject that has been our particular interest since 1990.
Collapse
Affiliation(s)
- Joshua J Klaene
- Department of Chemistry and Chemical Biology, Barnett Institute, Northeastern University, Boston, MA 02115, United States
| | - Vaneet K Sharma
- Department of Chemistry and Chemical Biology, Barnett Institute, Northeastern University, Boston, MA 02115, United States
| | - James Glick
- Department of Chemistry and Chemical Biology, Barnett Institute, Northeastern University, Boston, MA 02115, United States
| | - Paul Vouros
- Department of Chemistry and Chemical Biology, Barnett Institute, Northeastern University, Boston, MA 02115, United States.
| |
Collapse
|
22
|
Sharma VK, Glick J, Vouros P. Reversed-phase ion-pair liquid chromatography electrospray ionization tandem mass spectrometry for separation, sequencing and mapping of sites of base modification of isomeric oligonucleotide adducts using monolithic column. J Chromatogr A 2012; 1245:65-74. [PMID: 22652552 DOI: 10.1016/j.chroma.2012.05.003] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2012] [Revised: 05/01/2012] [Accepted: 05/01/2012] [Indexed: 11/17/2022]
Abstract
In this manuscript, an efficient high resolution reversed phase-ion pairing-liquid chromatography electrospray ionization tandem mass spectrometry (RP-IP-LC-MS/MS) method for separation of isomeric modified oligonucleotides using a polymeric (styrene-divinylbenzene) monolithic capillary column is presented. The effects of different ion pairing reagents (IPR), their concentration, mobile phase additives and conditions were evaluated towards achieving the highest possible resolution and chromatographic separation of isomeric oligonucleotides. Ion pairing reagents and mobile phase conditions were evaluated using as model N-acetylaminofluorene [AAF] adducted ss-oligonucleotides (CCC CGA GCA ATC TCA AT). The optimized mobile phase conditions were then applied for the mapping of sites of base modification of AAF adducted 15-base pair oligonucleotide fragments containing codon 135 of the p53 gene and for profiling a complex synthetic oligonucleotide mixture. The optimized method utilizes a monolithic poly(styrene-divinylbenzene) capillary column, triethylammonium bicarbonate as ion pairing reagent and methanol as organic modifier to perform IP-RPLC-ESI-MS/MS separation. The results show that the method is simultaneously applicable not only to oligonucleotide fragments adducted separately by different carcinogens but also to the analysis of multiple adducts in the same oligonucleotide fragment in a single experiment. The method presents itself as a tool for the identification, characterization and mapping of oligonucleotide adducts as biomarkers for DNA damage from carcinogens.
Collapse
Affiliation(s)
- Vaneet K Sharma
- Department of Chemistry and Chemical Biology, Barnett Institute, Northeastern University, Boston, MA 02115, USA
| | | | | |
Collapse
|
23
|
Sharma VK, Glick J, Liao Q, Shen C, Vouros P. GenoMass software: a tool based on electrospray ionization tandem mass spectrometry for characterization and sequencing of oligonucleotide adducts. JOURNAL OF MASS SPECTROMETRY : JMS 2012; 47:490-501. [PMID: 22689626 PMCID: PMC3375619 DOI: 10.1002/jms.2054] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
The analysis of DNA adducts is of importance in understanding DNA damage, and in the last few years mass spectrometry (MS) has emerged as the most comprehensive and versatile tool for routine characterization of modified oligonucleotides. The structural analysis of modified oligonucleotides, although routinely analyzed using mass spectrometry, is followed by a large amount of data, and a significant challenge is to locate the exact position of the adduct by computational spectral interpretation, which still is a bottleneck. In this report, we present an additional feature of the in-house developed GenoMass software, which determines the exact location of an adduct in modified oligonucleotides by connecting tandem mass spectrometry (MS/MS) to a combinatorial isomer library generated in silico for nucleic acids. The performance of this MS/MS approach using GenoMass software was evaluated by MS/MS data interpretation for an unadducted and its corresponding N-acetylaminofluorene (AAF) adducted 17-mer (5'OH-CCT ACC CCT TCC TTG TA-3'OH) oligonucleotide. Further computational screening of this AAF adducted 17-mer oligonucleotide (5'OH-CCT ACC CCT TCC TTG TA-3'OH) from a complex oligonucleotide mixture was performed using GenoMass. Finally, GenoMass was also used to identify the positional isomers of the AAF adducted 15-mer oligonucleotide (5'OH-ATGAACCGGAGGCCC-3'OH). GenoMass is a simple, fast, data interpretation software that uses an in silico constructed library to relate the MS/MS sequencing approach to identify the exact location of adduct on oligonucleotides.
Collapse
Affiliation(s)
- Vaneet K Sharma
- Department of Chemistry and Chemical Biology, Barnett Institute, Northeastern University, Boston, MA, 02115, USA
| | - James Glick
- Department of Chemistry and Chemical Biology, Barnett Institute, Northeastern University, Boston, MA, 02115, USA
| | - Qing Liao
- Shenitech LLC, Acton, MA, 01720, USA
| | | | - Paul Vouros
- Department of Chemistry and Chemical Biology, Barnett Institute, Northeastern University, Boston, MA, 02115, USA
| |
Collapse
|
24
|
Can NO. HPLC determination of cefprozil in tablets using monolithic and C18 silica columns. J Sep Sci 2011; 34:2223-31. [PMID: 21557474 DOI: 10.1002/jssc.201100170] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2011] [Revised: 03/20/2011] [Accepted: 03/28/2011] [Indexed: 02/04/2023]
Abstract
Cefprozil (CPZ) is a second-generation semi-synthetic cephalosporin antibiotic that commonly exists as the mixture of Z and E diastereoisomers, at the ratio of approximately 9:1. A novel reversed-phase HPLC method for the determination of CPZ in tablets was described. The separation of CPZ diastereoisomers and caffeine (internal standard) was carried out by applying the same analytical and instrumental conditions on two stationary phases, which have different surface chemistries. The columns used in the study were monolithic silica Merck Chromolith Performance RP-18e and conventional C18 silica Phenomenex Synergi Hydro RP columns. In total, 10 μL aliquots of samples were injected into the system and eluted using water-acetonitrile (90:10, v/v) solution, which was pumped through the column at a flow rate of 1.0 mL/min. The analyte peaks were detected at 200 nm using diode array detector with high specificity. CPZ diastereoisomers and caffeine were measured within 13 min using the C18 column, whereas <5 min was required for the monolithic one. Validation studies were performed according to official recommendations. Value of a monolithic column for the assay of diastereoisomers in pharmaceutical tablets was evaluated for the first time and found as a powerful alternative to highly efficient C18 columns.
Collapse
Affiliation(s)
- Nafiz O Can
- Department of Analytical Chemistry, Faculty of Pharmacy, Anadolu University, Eskisehir, Turkey.
| |
Collapse
|
25
|
Levin DS, Shepperd BT, Gruenloh CJ. Combining ion pairing agents for enhanced analysis of oligonucleotide therapeutics by reversed phase-ion pairing ultra performance liquid chromatography (UPLC). J Chromatogr B Analyt Technol Biomed Life Sci 2011; 879:1587-95. [PMID: 21514903 DOI: 10.1016/j.jchromb.2011.03.051] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2011] [Revised: 03/21/2011] [Accepted: 03/25/2011] [Indexed: 02/06/2023]
Abstract
The burgeoning field of oligonucleotide therapeutics is based upon synthetically derived biopolymers comprised of relatively simple RNA and DNA building blocks. Significant gains in knowledge around mechanisms of action (RNA interference, RNA splicing, etc.) and oligonucleotide design (ASO, siRNA, DsiRNA, miRNA, locked nucleic acid, etc.) have been the main drivers of recent investment for this field [1,2]. As therapeutics, there is currently great interest in oligonucleotides due to the reduced time required to achieve lead molecules and to their potential for treating previously untractable diseases. One of the more challenging areas for the field of oligonucleotide therapeutics is the development of high-quality analysis schemes for the determination of purity in drug substance and product. This, in part, is due to the fact that the synthesis of oligonucleotides results in a significant number of closely related impurities that are not easily removed during purification [1]. As a result, these macromolecules (4000-8000 MW on average, depending on chain length) and their soup of closely related impurities are typically not well resolved from one another via conventional chromatographic approaches. One of the more common chromatographic techniques used for oligonucleotide analysis is reversed phase-ion pairing liquid chromatography (RP-IP). Our research led us to the discovery that the use of multiple ion pairing agents combined in the mobile phase can improve the overall chromatographic resolution and peak shape of the oligonucleotide analytes over the use of a single ion pairing agent alone, resulting in enhanced purity analysis and the opportunity to identify related impurities with greater certainty. In addition, the use of combined ion pairing agents allowed for the development of a "universal" method which has provided superior chromatography for several different oligonucleotide compounds and their related impurities regardless of differences in nucleotide sequence. The RP-IP UPLC method conditions are ESI-MS compatible and have allowed for the mass identification of five positional isomeric impurities chromatographically resolved and present at less than 1% of the nominal parent peak area.
Collapse
Affiliation(s)
- Daren S Levin
- Exploratory Development Sciences, GlaxoSmithKline, RTP, NC 27709, USA.
| | | | | |
Collapse
|
26
|
Huang HY, Cheng YJ, Liu WL, Hsu YF, Lee S. Poly(divinylbenzene-alkyl methacrylate) monolithic stationary phases in capillary electrochromatography. J Chromatogr A 2010; 1217:5839-47. [DOI: 10.1016/j.chroma.2010.07.050] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2010] [Revised: 07/15/2010] [Accepted: 07/17/2010] [Indexed: 12/01/2022]
|
27
|
Oberacher H. Frontiers of mass spectrometry in nucleic acids analysis. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2010; 16:351-365. [PMID: 20530841 DOI: 10.1255/ejms.1045] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Nucleic acids research is a highly competitive field of research. A number of well established methods are available. The current output of high throughput ("next generation") sequencing technologies is impressive, and still technologies are continuing to make progress regarding read lengths, bp per second, accuracy and costs. Although in the 1990s MS was considered as an analytical platform for sequencing, it was soon realized that MS will never be competitive. Thus, the focus shifted from de novo sequencing towards other areas of application where MS has proven to be a powerful analytical tool. Potential niches for the application of MS in nucleic acids research include genotyping of genetic markers (single nucleotide polymorphisms, short tandem repeats, and combinations thereof), quality control of synthetic oligonucleotides, metabolic profiling of therapeutics, characterization of modified nucleobases in DNA and RNA molecules, and the study of non covalent interactions among nucleic acids as well as interactions of nucleic acids with drugs and proteins. The diversity of possible applications for MS highlights its significance for nucleic acid research.
Collapse
Affiliation(s)
- Herbert Oberacher
- Institute of Legal Medicine, Innsbruck Medical University, Innsbruck, Austria.
| |
Collapse
|
28
|
Randall KL, Argoti D, Paonessa JD, Ding Y, Oaks Z, Zhang Y, Vouros P. An improved liquid chromatography-tandem mass spectrometry method for the quantification of 4-aminobiphenyl DNA adducts in urinary bladder cells and tissues. J Chromatogr A 2009; 1217:4135-43. [PMID: 19932483 DOI: 10.1016/j.chroma.2009.11.006] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2009] [Revised: 09/30/2009] [Accepted: 11/02/2009] [Indexed: 12/01/2022]
Abstract
Exposure to 4-aminobiphenyl (4-ABP), an environmental and tobacco smoke carcinogen that targets the bladder urothelium, leads to DNA adduct formation and cancer development [1]. Two major analytical challenges in DNA adduct analysis of human samples have been limited sample availability and the need to reach detection limits approaching the part-per-billion threshold. By operating at nano-flow rates and incorporating a capillary analytical column in addition to an online sample enrichment step, we have developed a sensitive and quantitative HPLC-MS/MS method appropriate for the analysis of such samples. This assay for the deoxyguanosine adduct of 4-ABP (dG-C8-4-ABP) gave mass detection limits of 20amol in 1.25microg of DNA (5 adducts in 10(9) nucleosides) with a linear range of 70amol to 70fmol. 4-ABP-exposed human bladder cells and rat bladder tissue were analyzed in triplicate, and higher dose concentrations led to increased numbers of detected adducts. It was subsequently established that sample requirements could be further reduced to 1microg digestions and the equivalent of 250ng DNA per injection for the detection of low levels of dG-C8-4-ABP in a matrix of exfoliated human urothelial cell DNA. This method is appropriate for the characterization and quantification of DNA adducts in human samples and can lead to a greater understanding of their role in carcinogenesis and also facilitate evaluation of chemopreventive agents.
Collapse
Affiliation(s)
- Kristen L Randall
- Barnett Institute and Department of Chemistry and Chemical Biology, Northeastern University, 360 Huntington Ave, Boston, MA 02115, USA
| | | | | | | | | | | | | |
Collapse
|
29
|
Gibson GTT, Mugo SM, Oleschuk RD. Nanoelectrospray emitters: trends and perspective. MASS SPECTROMETRY REVIEWS 2009; 28:918-936. [PMID: 19479726 DOI: 10.1002/mas.20248] [Citation(s) in RCA: 101] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
The benefits of electrospray ionization are many, including sensitivity, robustness, simplicity and the ability to couple continuous flow methods with mass spectrometry. The technique has seen further improvement by lowering flow rates to the nanoelectrospray regime (<1,000 nL/min), where sample consumption is minimized and sensitivity increases. The move to nanoelectrospray has required a shift in the design of the electrospray source which has mostly involved the emitter itself. The emitter has seen an evolution in architecture as the shape and geometry of the device have proved pivotal in the formation of sufficiently small droplets for sensitive MS detection at these flow rates. There is a clear movement toward the development of emitters that produce multiple Taylor cones. Such multielectrospray emitters have been shown to provide enhanced sensitivity and sample utilization. This article reviews the development of nanoelectrospray emitters, including factors such as geometry and the manner of applying voltage. Designs for emitters that take advantage of multielectrospray are emphasized.
Collapse
Affiliation(s)
- Graham T T Gibson
- Department of Chemistry, Queen's University, Kingston, Ontario, Canada K7L 3N6
| | | | | |
Collapse
|
30
|
Su S, Gibson GTT, Mugo SM, Marecak DM, Oleschuk RD. Microstructured Photonic Fibers as Multichannel Electrospray Emitters. Anal Chem 2009; 81:7281-7. [DOI: 10.1021/ac901026t] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Shuqin Su
- Department of Chemistry, Queen’s University, Kingston, Ontario, Canada K7L 3N6
| | - Graham T. T. Gibson
- Department of Chemistry, Queen’s University, Kingston, Ontario, Canada K7L 3N6
| | - Samuel M. Mugo
- Department of Chemistry, Queen’s University, Kingston, Ontario, Canada K7L 3N6
| | - Dale M. Marecak
- Department of Chemistry, Queen’s University, Kingston, Ontario, Canada K7L 3N6
| | - Richard D. Oleschuk
- Department of Chemistry, Queen’s University, Kingston, Ontario, Canada K7L 3N6
| |
Collapse
|
31
|
Glick J, Xiong W, Lin Y, Noronha AM, Wilds CJ, Vouros P. The influence of cytosine methylation on the chemoselectivity of benzo[a]pyrene diol epoxide-oligonucleotide adducts determined using nanoLC/MS/MS. JOURNAL OF MASS SPECTROMETRY : JMS 2009; 44:1241-8. [PMID: 19536795 PMCID: PMC2752873 DOI: 10.1002/jms.1605] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Benzo[a]pyrene is a major carcinogen implicated in human lung cancer. Almost 60% of human lung cancers have a mutation in the p53 tumor suppressor gene at several specific codons. An on-line nanoLC/MS/MS method using a monolithic nanocolumn was applied to investigate the chemoselectivity of the carcinogenic diol epoxide metabolite, (+/-)-(7R,8S,9S,10R)-benzo[a]pyrene 7,8-diol 9,10-epoxide [(+/-)-anti-benzo[a]pyrene diol epoxide (BPDE)], which was reacted in vitro with a synthesized 14-mer double stranded oligonucleotide (5'-ACCCG5CG7TCCG11CG13C-3'/5'-GCGCGGGCGCGGGT-3') derived from the p53 gene. This sequence contained codons 157 and 158, which are considered mutational 'hot spots' and have also been reported as chemical 'hot spots' for the formation of BPDE-DNA adducts. In evaluating the effect of cytosine methylation on BPDE-DNA adduct binding, it was found that codon 156, containing the nucleobase G5 instead of the mutational hot spot codons 157 (G7) and 158 (G11), was the preferential chemoselective binding site for BPDE. In all permethylated cases studied, the relative ratio for adduction was found to be G5 >> G11 > G13 > G7. Permethylation of CpG dinucleotide sites on either the nontranscribed or complementary strand did not change the order of sequence preference but did enhance the relative adduction level of the G11 CpG site (codon 158) approximately two-fold versus the unmethylated oligomer. Permethylation of all CpG dinucleotide sites on the duplex changed the order of relative adduction to G5 >> G7 > G11 > G13. The three- to four-fold increase in adduction at the mutational hot spot codon 157 (G(7)) relative to the unmethylated or single-stranded permethylated cases suggests a possible relationship between the state of methylation and adduct formation for a particular mutation site in the p53 gene. Using this method, only 125 ng (30 pmol) of adducted oligonucleotide was analyzed with minimal sample cleanup and high chromatographic resolution of positional isomers in a single chromatographic run.
Collapse
Affiliation(s)
- James Glick
- Barnett Institute and Department of Chemistry, Northeastern University, Boston, MA 02115, USA
| | - Wennan Xiong
- Barnett Institute and Department of Chemistry, Northeastern University, Boston, MA 02115, USA
| | - Yiqing Lin
- Barnett Institute and Department of Chemistry, Northeastern University, Boston, MA 02115, USA
| | - Anne M. Noronha
- Department of Chemistry & Biochemistry, Concordia University, Montreal, Quebec H4B 1R6, Canada
| | - Christopher J. Wilds
- Department of Chemistry & Biochemistry, Concordia University, Montreal, Quebec H4B 1R6, Canada
| | - Paul Vouros
- Barnett Institute and Department of Chemistry, Northeastern University, Boston, MA 02115, USA
- Correspondence to: Paul Vouros, Barnett Institute and Department of Chemistry, Northeastern University, Boston, MA 02115, USA.
| |
Collapse
|
32
|
Liao Q, Shen C, Vouros P. GenoMass--a computer software for automated identification of oligonucleotide DNA adducts from LC-MS analysis of DNA digests. JOURNAL OF MASS SPECTROMETRY : JMS 2009; 44:549-560. [PMID: 19053159 PMCID: PMC2752885 DOI: 10.1002/jms.1532] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
In the investigation of oligonucleotides, DNA and their adducts by LC-MS, a myriad of data are generated that make manual data processing quite difficult. This paper describes a 'reversed pseudo-combinatorial' approach for fragment identification and the software implementation of this approach. Combinatorial isomer libraries are generated in silico to represent the digestion products of oligonucleotides, DNA or DNA adducts of various sizes. The software automatically calculates ion masses of each isomeric segment of the library, searches for them in complicated LC-MS data, lists their intensities and plots extracted ion chromatograms (EIC). This customized new data analysis tool has enabled a study of the enzymatic behavior of a nuclease system in the digestion of normal and adducted DNA, and in the recognition of oligomers containing a carcinogen bound to a nucleobase. The software program potentially can be further expanded to postulate unknown DNA sequences and recognize the adduction sites.
Collapse
Affiliation(s)
- Qing Liao
- Mass Spectrometry Center, FAS Center for System Biology, Harvard University, Cambridge, MA 02138, USA
| | | | - Paul Vouros
- Department of Chemistry and Chemical Biology, Northeastern University, Boston, MA 02115, USA
| |
Collapse
|
33
|
Chowdhury G, Guengerich FP. Direct detection and mapping of sites of base modification in DNA fragments by tandem mass spectrometry. Angew Chem Int Ed Engl 2008; 47:381-4. [PMID: 18022988 DOI: 10.1002/anie.200703942] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Goutam Chowdhury
- Department of Biochemistry, Center in Molecular Toxicology, Vanderbilt University School of Medicine, 638 Robinson Research Building, 2220 Pierce Ave., Nashville, TN 37232, USA
| | | |
Collapse
|
34
|
Chowdhury G, Guengerich F. Direct Detection and Mapping of Sites of Base Modification in DNA Fragments by Tandem Mass Spectrometry. Angew Chem Int Ed Engl 2008. [DOI: 10.1002/ange.200703942] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
35
|
Forensic DNA fingerprinting by liquid chromatography-electrospray ionization mass spectrometry. Biotechniques 2007; 43:vii-xiii. [PMID: 18019345 DOI: 10.2144/000112581] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
The determination of the molecular mass of a DNA sequence has several benefits over conventional fragment-length analysis that are advantageous to the forensic field: (i) sequence variation is captured that increases the power of discrimination compared with that obtained by conventional fragment-length analysis. First experiments showed that this increase makes up to 20%-30% for STR analysis. The new technical approach does not invalidate established developments and data, but adds to this information with additional discriminative categories. (ii) ICEMS is faster and cheaper than electrophoresis, does not require internal size standards, allelic ladders, or spectral calibration, which are necessary for fluorescence-based electrophoresis. (iii) ICEMS can unequivocally detect any single sequence variation in DNA molecules with lengths up to 250 nucleotides. This allows for maximum discrimination of forensically relevant DNA fragments, covering all sorts of STRs, SNPs, and also the analysis of the hypervariable segments of mtDNA. More effort, however, needs to be put into software development that escorts the analysis and data interpretation processes to make this technology manageable for the practical user.
Collapse
|