1
|
Hayter EA, Azibere S, Skrajewski LA, Soule LD, Spence DM, Martin RS. A 3D-printed, multi-modal microfluidic device for measuring nitric oxide and ATP release from flowing red blood cells. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:3171-3179. [PMID: 35959771 PMCID: PMC10227723 DOI: 10.1039/d2ay00931e] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
In this paper, a 3D-printed multi-modal device was designed and fabricated to simultaneously detect nitric oxide (NO) and adenosine triphosphate (ATP) in red blood cell suspensions prepared from whole blood. Once a sample was injected into the device, NO was first detected (via amperometry) using a three-electrode, dual-opposed, electrode configuration with a platinum-black/Nafion coated gold working electrode. After in-line amperometric detection of NO, ATP was detected via a chemiluminescence reaction, with a luciferin/luciferase solution continuously pumped into an integrated mixing T and the resulting light being measured with a PMT underneath the channel. The device was optimized for mixing/reaction conditions, limits of detection (40 nM for NO and 30 nM for ATP), and sensitivity. This device was used to determine the basal (normoxic) levels of NO and ATP in red blood cells, as well as an increase in concentration of both analytes under hypoxic conditions. Finally, the effect of storing red blood cells in a commonly used storage solution was also investigated by monitoring the production of NO and ATP over a three-week storage time.
Collapse
Affiliation(s)
- Elizabeth A Hayter
- Department of Chemistry, Saint Louis University, 3501 Laclede Ave St. Louis, MO, USA, 63103.
| | - Samuel Azibere
- Department of Chemistry, Saint Louis University, 3501 Laclede Ave St. Louis, MO, USA, 63103.
| | - Lauren A Skrajewski
- Department of Biomedical Engineering, Institute for Quantitative Health Science & Engineering, Michigan State University, USA
| | - Logan D Soule
- Department of Biomedical Engineering, Institute for Quantitative Health Science & Engineering, Michigan State University, USA
| | - Dana M Spence
- Department of Biomedical Engineering, Institute for Quantitative Health Science & Engineering, Michigan State University, USA
| | - R Scott Martin
- Department of Chemistry, Saint Louis University, 3501 Laclede Ave St. Louis, MO, USA, 63103.
- Center for Additive Manufacturing, Saint Louis University, USA
| |
Collapse
|
2
|
Geiger M, Hayter E, Martin R, Spence D. Red blood cells in type 1 diabetes and multiple sclerosis and technologies to measure their emerging roles. J Transl Autoimmun 2022; 5:100161. [PMID: 36039310 PMCID: PMC9418496 DOI: 10.1016/j.jtauto.2022.100161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Revised: 07/14/2022] [Accepted: 07/21/2022] [Indexed: 11/15/2022] Open
Affiliation(s)
- M. Geiger
- Institute of Quantitative Health Sciences and Engineering, Michigan State University, East Lansing, MI 48824, USA
- Department of Biomedical Engineering, Michigan State University, East Lansing, MI 48824, USA
| | - E. Hayter
- Department of Chemistry, Saint Louis University, St. Louis, MO 63103, USA
| | - R.S. Martin
- Department of Chemistry, Saint Louis University, St. Louis, MO 63103, USA
| | - D. Spence
- Institute of Quantitative Health Sciences and Engineering, Michigan State University, East Lansing, MI 48824, USA
- Department of Biomedical Engineering, Michigan State University, East Lansing, MI 48824, USA
- Corresponding author. 775 Woodlot Drive, East Lansing, MI 48824, USA.
| |
Collapse
|
3
|
He S, Cheng Z. Near-Infrared II Optical Imaging. Mol Imaging 2021. [DOI: 10.1016/b978-0-12-816386-3.00025-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
|
4
|
Dulay S, Rivas L, Miserere S, Pla L, Berdún S, Parra J, Eixarch E, Gratacós E, Illa M, Mir M, Samitier J. in vivo Monitoring with micro-implantable hypoxia sensor based on tissue acidosis. Talanta 2020; 226:122045. [PMID: 33676640 DOI: 10.1016/j.talanta.2020.122045] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Revised: 12/17/2020] [Accepted: 12/21/2020] [Indexed: 12/22/2022]
Abstract
Hypoxia is a common medical problem, sometimes difficult to detect and caused by different situations. Control of hypoxia is of great medical importance and early detection is essential to prevent life threatening complications. However, the few current methods are invasive, expensive, and risky. Thus, the development of reliable and accurate sensors for the continuous monitoring of hypoxia is of vital importance for clinical monitoring. Herein, we report an implantable sensor to address these needs. The developed device is a low-cost, miniaturised implantable electrochemical sensor for monitoring hypoxia in tissue by means of pH detection. This technology is based on protonation/deprotonation of polypyrrole conductive polymer. The sensor was optimized in vitro and tested in vivo intramuscularly and ex vivo in blood in adult rabbits with respiration-induced hypoxia and correlated with the standard device ePOCTM. The sensor demonstrated excellent sensitivity and reproducibility; 46.4 ± 0.4 mV/pH in the pH range of 4-9 and the selectivity coefficient exhibited low interference activity in vitro. The device was linear (R2 = 0.925) with a low dispersion of the values (n = 11) with a cut-off of 7.1 for hypoxia in vivo and ex vivo. Statistics with one-way ANOVA (α = 0.05), shows statistical differences between hypoxia and normoxia states and the good performance of the pH sensor, which demonstrated good agreement with the standard device. The sensor was stable and functional after 18 months. The excellent results demonstrated the feasibility of the sensors in real-time monitoring of intramuscular tissue and blood for medical applications.
Collapse
Affiliation(s)
- Samuel Dulay
- Nanobioengineering Group, Institute for Bioengineering of Catalonia (IBEC) Barcelona Institute of Science and Technology (BIST), 12 Baldiri Reixac 15-21, Barcelona, 08028, Spain
| | - Lourdes Rivas
- Nanobioengineering Group, Institute for Bioengineering of Catalonia (IBEC) Barcelona Institute of Science and Technology (BIST), 12 Baldiri Reixac 15-21, Barcelona, 08028, Spain
| | - Sandrine Miserere
- Nanobioengineering Group, Institute for Bioengineering of Catalonia (IBEC) Barcelona Institute of Science and Technology (BIST), 12 Baldiri Reixac 15-21, Barcelona, 08028, Spain
| | - Laura Pla
- Fetal Medicine Research Center, BCNatal. Hospital Clínic and Hospital Sant Joan de Déu, Universitat de Barcelona. Building Helios 2, Sabino Arana Street 1, 08028, Barcelona, Spain
| | - Sergio Berdún
- Fetal Medicine Research Center, BCNatal. Hospital Clínic and Hospital Sant Joan de Déu, Universitat de Barcelona. Building Helios 2, Sabino Arana Street 1, 08028, Barcelona, Spain
| | - Johanna Parra
- Fetal Medicine Research Center, BCNatal. Hospital Clínic and Hospital Sant Joan de Déu, Universitat de Barcelona. Building Helios 2, Sabino Arana Street 1, 08028, Barcelona, Spain
| | - Elisenda Eixarch
- Fetal Medicine Research Center, BCNatal. Hospital Clínic and Hospital Sant Joan de Déu, Universitat de Barcelona. Building Helios 2, Sabino Arana Street 1, 08028, Barcelona, Spain; Institut D'Investigacions Biomèdiques August Pi I Sunyer (IDIBAPS), Barcelona, Spain
| | - Eduard Gratacós
- Fetal Medicine Research Center, BCNatal. Hospital Clínic and Hospital Sant Joan de Déu, Universitat de Barcelona. Building Helios 2, Sabino Arana Street 1, 08028, Barcelona, Spain; Institut D'Investigacions Biomèdiques August Pi I Sunyer (IDIBAPS), Barcelona, Spain
| | - Míriam Illa
- Fetal Medicine Research Center, BCNatal. Hospital Clínic and Hospital Sant Joan de Déu, Universitat de Barcelona. Building Helios 2, Sabino Arana Street 1, 08028, Barcelona, Spain
| | - Mònica Mir
- Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Monforte de Lemos 3-5, Pabellón 11, 28029, Madrid, Spain; Nanobioengineering Group, Institute for Bioengineering of Catalonia (IBEC) Barcelona Institute of Science and Technology (BIST), 12 Baldiri Reixac 15-21, Barcelona, 08028, Spain; Department of Electronics and Biomedical Engineering, Universitat de Barcelona, Martí I Franquès 1, 08028, Barcelona, Spain.
| | - Josep Samitier
- Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Monforte de Lemos 3-5, Pabellón 11, 28029, Madrid, Spain; Nanobioengineering Group, Institute for Bioengineering of Catalonia (IBEC) Barcelona Institute of Science and Technology (BIST), 12 Baldiri Reixac 15-21, Barcelona, 08028, Spain; Department of Electronics and Biomedical Engineering, Universitat de Barcelona, Martí I Franquès 1, 08028, Barcelona, Spain
| |
Collapse
|
5
|
Xiong J, Xie R, Wang Y, Wang C, Ai Y, Zheng W, Ding M, Gao J, Wang J, Liang Q. Nitrite-Responsive Hydrogel: Smart Drug Release Depending on the Severity of the Nitric Oxide-Related Disease. ACS APPLIED MATERIALS & INTERFACES 2020; 12:51185-51197. [PMID: 33146508 DOI: 10.1021/acsami.0c13688] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Nitric oxide (NO) is known as one of the most important biomarkers of many diseases. However, the development of NO-triggered drug releasing platforms is challenging due to the low concentration and short lifetime of NO in vivo. In this work, a novel nitrite (NO2-)-responsive hydrogel (DHPL-GEL), which can be used for smart drug release depending on the severity of the NO-related disease, is demonstrated. A dihydropyridine cross-linking agent is designed to construct DHPL-GEL to enable the responsive degradation of the hydrogel triggered by NO2-. On-demand release of the drug loaded in DHPL-GEL was observed under the stimulation of various concentrations of NO2- at the physiological level both in vitro and in vivo. In the inflammatory arthritis rat model, the DHPL-GEL drug delivery system showed a better therapeutic effect and less side effects than the traditional therapy and nonresponsive hydrogel drug delivery system, demonstrating the promising application of the NO2--responsive hydrogel for the treatment of NO-related diseases.
Collapse
Affiliation(s)
- Jialiang Xiong
- MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology, Beijing Key Lab of Microanalytical Methods & Instrumentation, Department of Chemistry, Center for Synthetic and Systems Biology, Tsinghua University, Beijing 100084, P. R. China
| | - Ruoxiao Xie
- MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology, Beijing Key Lab of Microanalytical Methods & Instrumentation, Department of Chemistry, Center for Synthetic and Systems Biology, Tsinghua University, Beijing 100084, P. R. China
| | - Yu Wang
- MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology, Beijing Key Lab of Microanalytical Methods & Instrumentation, Department of Chemistry, Center for Synthetic and Systems Biology, Tsinghua University, Beijing 100084, P. R. China
| | - Chenlong Wang
- MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology, Beijing Key Lab of Microanalytical Methods & Instrumentation, Department of Chemistry, Center for Synthetic and Systems Biology, Tsinghua University, Beijing 100084, P. R. China
| | - Yongjian Ai
- MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology, Beijing Key Lab of Microanalytical Methods & Instrumentation, Department of Chemistry, Center for Synthetic and Systems Biology, Tsinghua University, Beijing 100084, P. R. China
| | - Wenchen Zheng
- MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology, Beijing Key Lab of Microanalytical Methods & Instrumentation, Department of Chemistry, Center for Synthetic and Systems Biology, Tsinghua University, Beijing 100084, P. R. China
| | - Mingyu Ding
- MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology, Beijing Key Lab of Microanalytical Methods & Instrumentation, Department of Chemistry, Center for Synthetic and Systems Biology, Tsinghua University, Beijing 100084, P. R. China
| | - Jianyi Gao
- China Astronaut Research and Training Center, Beijing 100094, P. R. China
| | - Jiaping Wang
- China Astronaut Research and Training Center, Beijing 100094, P. R. China
| | - Qionglin Liang
- MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology, Beijing Key Lab of Microanalytical Methods & Instrumentation, Department of Chemistry, Center for Synthetic and Systems Biology, Tsinghua University, Beijing 100084, P. R. China
| |
Collapse
|
6
|
Liu X, Feng T, Ji W, Wang Z, Zhang M. A cobalt corrole/carbon nanotube enables simultaneous electrochemical monitoring of oxygen and ascorbic acid in the rat brain. Analyst 2019; 145:70-75. [PMID: 31720591 DOI: 10.1039/c9an01946d] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
It is of interest to in vivo monitor the co-dynamics of different substances. However, the tracking of multiple species is still challenging. In this work, we demonstrate an in vivo electrochemical method by using multi-potential step amperometry to in vivo detect ascorbic acid (AA) and oxygen (O2) simultaneously. In order to achieve good selectivity and high sensitivity for both AA and O2, we design a cobalt corrole [Co(tpfc)(py)2] (tpfc = 5,10,15-tris(penta-fluorophenyl) corrole, py = pyridine, denoted as Co-TPFC) and carbon nanotube nanocomposite to modify a carbon fiber microelectrode (Co-TPFC/MWNT/CFE). This Co-TPFC/MWNT/CFE exhibits excellent electrocatalytic properties towards the reduction of O2 preceding a 4e process and facilitates the oxidation of AA at low potential in the physiological environment. Based on this, we realize simultaneous detection of AA and O2 using two-potential steps (one cathodic (-0.2 V) and the other anodic (+0.05 V)) with 1 second step time. Both in vitro and in vivo experiments proved the feasibility of this method. This demonstrated strategy is useful for us to understand various physiological and pathological processes associated with O2 and AA co-dynamics, and also provides an idea for detecting multiple substances simultaneously.
Collapse
Affiliation(s)
- Xiaomeng Liu
- Department of Chemistry, Renmin University of China, Beijing 100872, China.
| | | | | | | | | |
Collapse
|
7
|
Brown MD, Schoenfisch MH. Electrochemical Nitric Oxide Sensors: Principles of Design and Characterization. Chem Rev 2019; 119:11551-11575. [DOI: 10.1021/acs.chemrev.8b00797] [Citation(s) in RCA: 58] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Affiliation(s)
- Micah D. Brown
- Department of Chemistry, University of North Carolina at Chapel Hill, CB 3290, Chapel Hill, North Carolina 27599, United States
| | - Mark H. Schoenfisch
- Department of Chemistry, University of North Carolina at Chapel Hill, CB 3290, Chapel Hill, North Carolina 27599, United States
| |
Collapse
|
8
|
Xiao T, Li X, Wei H, Ji W, Yue Q, Yu P, Mao L. In Vivo Monitoring of Oxygen Fluctuation Simultaneously at Multiple Sites of Rat Cortex during Spreading Depression. Anal Chem 2018; 90:13783-13789. [DOI: 10.1021/acs.analchem.8b04348] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Affiliation(s)
- Tongfang Xiao
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, the Chinese Academy of Sciences (CAS), CAS Research/Education Center for Excellence in Molecule Science, Beijing 100190, China
| | - Xianchan Li
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, the Chinese Academy of Sciences (CAS), CAS Research/Education Center for Excellence in Molecule Science, Beijing 100190, China
| | - Huan Wei
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, the Chinese Academy of Sciences (CAS), CAS Research/Education Center for Excellence in Molecule Science, Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Wenliang Ji
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, the Chinese Academy of Sciences (CAS), CAS Research/Education Center for Excellence in Molecule Science, Beijing 100190, China
| | - Qingwei Yue
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, the Chinese Academy of Sciences (CAS), CAS Research/Education Center for Excellence in Molecule Science, Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Ping Yu
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, the Chinese Academy of Sciences (CAS), CAS Research/Education Center for Excellence in Molecule Science, Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Lanqun Mao
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, the Chinese Academy of Sciences (CAS), CAS Research/Education Center for Excellence in Molecule Science, Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
9
|
Abstract
Recent progress in the electrochemical field enabled development of miniaturized sensing devices that can be used in biological settings to obtain fundamental and practical biochemically relevant information on physiology, metabolism, and disease states in living systems. Electrochemical sensors and biosensors have demonstrated potential for rapid, real-time measurements of biologically relevant molecules. This chapter provides an overview of the most recent advances in the development of miniaturized sensors for biological investigations in living systems, with focus on the detection of neurotransmitters and oxidative stress markers. The design of electrochemical (bio)sensors, including their detection mechanism and functionality in biological systems, is described as well as their advantages and limitations. Application of these sensors to studies in live cells, embryonic development, and rodent models is discussed.
Collapse
|
10
|
Li R, Liu X, Qiu W, Zhang M. In Vivo Monitoring of H2O2 with Polydopamine and Prussian Blue-coated Microelectrode. Anal Chem 2016; 88:7769-76. [DOI: 10.1021/acs.analchem.6b01765] [Citation(s) in RCA: 65] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Affiliation(s)
- Ruixin Li
- Department
of Chemistry, Renmin University of China, Beijing 100872, China
| | - Xiaomeng Liu
- Department
of Chemistry, Renmin University of China, Beijing 100872, China
| | - Wanling Qiu
- Department
of Chemistry, Renmin University of China, Beijing 100872, China
| | - Meining Zhang
- Department
of Chemistry, Renmin University of China, Beijing 100872, China
| |
Collapse
|
11
|
Özel RE, Hayat A, Andreescu S. RECENT DEVELOPMENTS IN ELECTROCHEMICAL SENSORS FOR THE DETECTION OF NEUROTRANSMITTERS FOR APPLICATIONS IN BIOMEDICINE. ANAL LETT 2015; 48:1044-1069. [PMID: 26973348 PMCID: PMC4787221 DOI: 10.1080/00032719.2014.976867] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Neurotransmitters are important biological molecules that are essential to many neurophysiological processes including memory, cognition, and behavioral states. The development of analytical methodologies to accurately detect neurotransmitters is of great importance in neurological and biological research. Specifically designed microelectrodes or microbiosensors have demonstrated potential for rapid, real-time measurements with high spatial resolution. Such devices can facilitate study of the role and mechanism of action of neurotransmitters and can find potential uses in biomedicine. This paper reviews the current status and recent advances in the development and application of electrochemical sensors for the detection of small-molecule neurotransmitters. Measurement challenges and opportunities of electroanalytical methods to advance study and understanding of neurotransmitters in various biological models and disease conditions are discussed.
Collapse
Affiliation(s)
- Rıfat Emrah Özel
- Department of Chemistry and Biomolecular Science, Clarkson University, Potsdam, NY, USA. Fax: 3152686610; Tel: 3152682394
| | - Akhtar Hayat
- Department of Chemistry and Biomolecular Science, Clarkson University, Potsdam, NY, USA. Fax: 3152686610; Tel: 3152682394
- Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS Institute of Information Technology (CIIT), Lahore, Pakistan
| | - Silvana Andreescu
- Department of Chemistry and Biomolecular Science, Clarkson University, Potsdam, NY, USA. Fax: 3152686610; Tel: 3152682394
| |
Collapse
|
12
|
Park SS, Hong M, Ha Y, Sim J, Jhon GJ, Lee Y, Suh M. The real-time in vivo electrochemical measurement of nitric oxide and carbon monoxide release upon direct epidural electrical stimulation of the rat neocortex. Analyst 2015; 140:3415-21. [PMID: 25751504 DOI: 10.1039/c5an00122f] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
This study reports real-time, in vivo functional measurement of nitric oxide (NO) and carbon monoxide (CO), two gaseous mediators in controlling cerebral blood flow. A dual electrochemical NO/CO microsensor enables us to probe the complex relationship between NO and CO in regulating cerebrovascular tone. Utilizing this dual sensor, we monitor in vivo change of NO and CO simultaneously during direct epidural electrical stimulation of a living rat brain cortex. Both NO and CO respond quickly to meet physiological needs. The neural system instantaneously increases the released amounts of NO and CO to compensate the abrupt, yet transient hypoxia that results from epidural electrical stimulation. Intrinsic-signal optical imaging confirms that direct electrical stimulation elicits robust, dynamic changes in cerebral blood flow, which must accompany NO and CO signaling. The addition of l-arginine (a substrate for NO synthase, NOS) results in increased NO generation and decreased CO production compared to control stimulation. On the other hand, application of the NOS inhibitor, l-N(G)-nitroarginine methyl ester (l-NAME), results in decreased NO release but increased CO production of greater magnitude. This observation suggests that the interaction between NO and CO release is likely not linear and yet, they are tightly linked vasodilators.
Collapse
Affiliation(s)
- Sarah S Park
- Department of Chemistry and Nano Science, Ewha Womans University, Seoul, 120-750, Republic of Korea.
| | | | | | | | | | | | | |
Collapse
|
13
|
Bruinsma BG, Yarmush ML, Uygun K. Organomatics and organometrics: Novel platforms for long-term whole-organ culture. TECHNOLOGY 2014; 2:13. [PMID: 25035864 PMCID: PMC4097862 DOI: 10.1142/s2339547814300029] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Organ culture systems are instrumental as experimental whole-organ models of physiology and disease, as well as preservation modalities facilitating organ replacement therapies such as transplantation. Nevertheless, a coordinated system of machine perfusion components and integrated regulatory control has yet to be fully developed to achieve long-term maintenance of organ function ex vivo. Here we outline current strategies for organ culture, or organomatics, and how these systems can be regulated by means of computational algorithms, or organometrics, to achieve the organ culture platforms anticipated in modern-day biomedicine.
Collapse
|
14
|
de Mel A, Naghavi N, Cousins BG, Clatworthy I, Hamilton G, Darbyshire A, Seifalian AM. Nitric oxide-eluting nanocomposite for cardiovascular implants. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2014; 25:917-929. [PMID: 24293239 DOI: 10.1007/s10856-013-5103-2] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/01/2013] [Accepted: 11/18/2013] [Indexed: 06/02/2023]
Abstract
Cardiovascular implants must resist thrombosis and intimal hyperplasia, but they are prone to such patency limiting conditions during graft implantation and prior to endothelialisation. Nitric oxide (NO) released from the endothelium has a complex protective role in the cardiovascular system, and this study has addressed: (1) in situ NO release profiles from S-nitrosothiols ((S-Nitroso-N-acetylpenicillamine (SNAP) and (S-Nitrosoglutathione (GSNO)) incorporated into polyhedral oligomeric silsesquioxanepoly(carbonate-urea)urethane (POSS-PCU) coronary artery bypass grafts (CABG) in a physiological pulsatile flow, and (2) the determination of their interaction with endothelial progenitor cells (EPCs), smooth muscle cells, platelets, whole blood kinetics. It was found that 1, 2, and 3 wt% SNAP/GSNO incorporated into POSS-PCU-CABG successfully eluted NO, but optimal elution was evident with 2 %-SNAP-POSS-PCU. NO release determined under static conditions using the Griess assay, and in situ measurements under pulsatile flow using amperometric probe was found to differ, thus confirming the significance of monitoring NO-elution under haemodynamic conditions. 2 %-SNAP-POSS-PCU demonstrated anti-thrombogenic kinetics through thromboelastography measurements, while metabolic activity using Alamar Blue™ assay and scanning electron microscopy demonstrated greater adhesion of EPCs and reduced adhesion of platelets.
Collapse
Affiliation(s)
- Achala de Mel
- Centre for Nanotechnology & Regenerative Medicine, University College London, London, UK
| | | | | | | | | | | | | |
Collapse
|
15
|
Lourenço CF, Ferreira NR, Santos RM, Lukacova N, Barbosa RM, Laranjinha J. The pattern of glutamate-induced nitric oxide dynamics in vivo and its correlation with nNOS expression in rat hippocampus, cerebral cortex and striatum. Brain Res 2014; 1554:1-11. [PMID: 24495843 DOI: 10.1016/j.brainres.2014.01.030] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2013] [Revised: 01/13/2014] [Accepted: 01/18/2014] [Indexed: 01/20/2023]
Abstract
Nitric oxide (NO) is a diffusible intercellular messenger, acting via volume signaling in the brain and, therefore, the knowledge of its temporal dynamics is determinant to the understanding of its neurobiological role. However, such an analysis in vivo is challenging and indirect or static approaches are mostly used to infer NO bioactivity. In the present work we measured the glutamate-dependent NO temporal dynamics in vivo in the hippocampus (CA1, CA3 and DG subregions), cerebral cortex and striatum, using NO selective microelectrodes. Concurrently, the immunolocalization of nNOS was evaluated in each region. A transitory increase in NO levels occurred at higher amplitudes in the striatum and hippocampus relatively to the cortex. In the hippocampus, subtle differences in the profiles of NO signals were observed along the trisynaptic loop, with CA1 exhibiting the largest signals. The topography of NO temporal dynamics did not fully overlap with the pattern of the density of nNOS expression, suggesting that, complementary to the distribution of nNOS, the local regulation of NO synthesis as well as the decay pathways critically determine the effective NO concentration sensed by a target within the diffusional spread of this free radical. In sum, the rate and pattern of NO changes here shown, by incorporating regulatory mechanisms and processes that affect NO synthesis and decay, provide refined information critical for the understanding of NO multiple actions in the brain.
Collapse
Affiliation(s)
- C F Lourenço
- Faculty of Pharmacy and Center for Neurosciences and Cell Biology, University of Coimbra, Azinhaga de Santa Comba, 3000-548 Coimbra, Portugal
| | - N R Ferreira
- Faculty of Pharmacy and Center for Neurosciences and Cell Biology, University of Coimbra, Azinhaga de Santa Comba, 3000-548 Coimbra, Portugal
| | - R M Santos
- Faculty of Pharmacy and Center for Neurosciences and Cell Biology, University of Coimbra, Azinhaga de Santa Comba, 3000-548 Coimbra, Portugal
| | - N Lukacova
- Institute of Neurobiology, Slovak Academy of Sciences, Soltésovej 4, 040 01 Kosice, Slovak Republic
| | - R M Barbosa
- Faculty of Pharmacy and Center for Neurosciences and Cell Biology, University of Coimbra, Azinhaga de Santa Comba, 3000-548 Coimbra, Portugal
| | - J Laranjinha
- Faculty of Pharmacy and Center for Neurosciences and Cell Biology, University of Coimbra, Azinhaga de Santa Comba, 3000-548 Coimbra, Portugal.
| |
Collapse
|
16
|
Iverson NM, Barone PW, Shandell M, Trudel LJ, Sen S, Sen F, Ivanov V, Atolia E, Farias E, McNicholas TP, Reuel N, Parry NMA, Wogan GN, Strano MS. In vivo biosensing via tissue-localizable near-infrared-fluorescent single-walled carbon nanotubes. NATURE NANOTECHNOLOGY 2013; 8:873-80. [PMID: 24185942 PMCID: PMC4066962 DOI: 10.1038/nnano.2013.222] [Citation(s) in RCA: 193] [Impact Index Per Article: 17.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/22/2013] [Accepted: 09/26/2013] [Indexed: 05/17/2023]
Abstract
Single-walled carbon nanotubes are particularly attractive for biomedical applications, because they exhibit a fluorescent signal in a spectral region where there is minimal interference from biological media. Although single-walled carbon nanotubes have been used as highly sensitive detectors for various compounds, their use as in vivo biomarkers requires the simultaneous optimization of various parameters, including biocompatibility, molecular recognition, high fluorescence quantum efficiency and signal transduction. Here we show that a polyethylene glycol ligated copolymer stabilizes near-infrared-fluorescent single-walled carbon nanotubes sensors in solution, enabling intravenous injection into mice and the selective detection of local nitric oxide concentration with a detection limit of 1 µM. The half-life for liver retention is 4 h, with sensors clearing the lungs within 2 h after injection, thus avoiding a dominant route of in vivo nanotoxicology. After localization within the liver, it is possible to follow the transient inflammation using nitric oxide as a marker and signalling molecule. To this end, we also report a spatial-spectral imaging algorithm to deconvolute fluorescence intensity and spatial information from measurements. Finally, we demonstrate that alginate-encapsulated single-walled carbon nanotubes can function as implantable inflammation sensors for nitric oxide detection, with no intrinsic immune reactivity or other adverse response for more than 400 days.
Collapse
Affiliation(s)
- Nicole M Iverson
- 1] Department of Chemical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, Massachusetts 02139, USA [2] Department of Biological Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, Massachusetts 02139, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Lee GJ, Kim SK, Kang SW, Kim OK, Chae SJ, Choi S, Shin JH, Park HK, Chung JH. Real time measurement of myocardial oxygen dynamics during cardiac ischemia-reperfusion of rats. Analyst 2013; 137:5312-9. [PMID: 23016151 DOI: 10.1039/c2an35208g] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Because oxygen plays a critical role in the pathophysiology of myocardial injury during subsequent reperfusion, as well as ischemia, the accurate measurement of myocardial oxygen tension is crucial for the assessment of myocardial viability by ischemia-reperfusion (IR) injury. Therefore, we utilized a sol-gel derived electrochemical oxygen microsensor to monitor changes in oxygen tension during myocardial ischemia-reperfusion. We also analyzed differences in oxygen tension recovery in post-ischemic myocardium depending on ischemic time to investigate the correlation between recovery parameters for oxygen tension and the severity of IR injury. An oxygen sensor was built using a xerogel-modified platinum microsensor and a coiled Ag/AgCl reference electrode. Rat hearts were randomly divided into 5 groups: control (0 min ischemia), I-10 (10 min ischemia), I-20 (20 min ischemia), I-30 (30 min ischemia), and I-40 (40 min ischemia) groups (n = 3 per group, respectively). After the induction of ischemia, reperfusion was performed for 60 min. As soon as the ischemia was initiated, oxygen tension rapidly declined to near zero levels. When reperfusion was initiated, the changes in oxygen tension depended on ischemic time. The normalized peak level of oxygen tension during the reperfusion episode was 188 ± 27 in group I-10, 120 ± 24 in group I-20, 12.5 ± 10.6 in group I-30, and 1.24 ± 1.09 in group I-40 (p < 0.001, n = 3, respectively). After 60 min of reperfusion, the normalized restoration level was 129 ± 30 in group I-10, 88 ± 4 in group I-20, 3.40 ± 4.82 in group I-30, and 0.99 ± 0.94 in group I-40 (p < 0.001, n = 3, respectively). The maximum and restoration values of oxygen tension in groups I-30 and I-40 after reperfusion were lower than pre-ischemic values. In particular, oxygen tension in the I-40 group was not recovered at all. These results were also demonstrated by TTC staining. We suggest that these recovery parameters could be utilized as an index of tissue injury and severity of ischemia. Therefore, quantitative measurements of oxygen tension dynamics in the myocardium would be helpful for evaluation of the cardioprotective effects of therapeutic treatments such as drug administration.
Collapse
Affiliation(s)
- Gi-Ja Lee
- Department of Biomedical Engineering & Healthcare Industry Research Institute, College of Medicine, Kyung Hee University, Seoul 130-701, Korea
| | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Overview of significant examples of electrochemical sensor arrays designed for detection of nitric oxide and relevant species in a biological environment. Anal Bioanal Chem 2013; 405:3475-88. [PMID: 23334219 DOI: 10.1007/s00216-012-6671-6] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2012] [Revised: 12/04/2012] [Accepted: 12/18/2012] [Indexed: 12/15/2022]
Abstract
Ultramicroelectrode sensor arrays in which each electrode, or groups of electrodes, are individually addressable are of particular interest for detection of several species concomitantly, by using specific sensing chemistry for each analyte, or for mapping of one analyte to achieve spatio-temporal analysis. Microfabrication technology, for example photolitography, is usually used for fabrication of these arrays. The most widespread geometries produced by photolithography are thin-film microdisc electrode arrays with different electrode distributions (square, hexagonal, or random). In this paper we review different electrochemical sensor arrays developed to monitor, in vivo, NO levels produced by cultured cells or sliced tissues. Simultaneous detection of NO and analytes interacting with or released at the same time as NO is also discussed.
Collapse
|
19
|
Ha Y, Myung D, Shim JH, Kim MH, Lee Y. A dual electrochemical microsensor for simultaneous imaging of oxygen and pH over the rat kidney surface. Analyst 2013; 138:5258-64. [DOI: 10.1039/c3an00878a] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
20
|
Cheng H, Yu P, Lu X, Lin Y, Ohsaka T, Mao L. Biofuel cell-based self-powered biogenerators for online continuous monitoring of neurochemicals in rat brain. Analyst 2013; 138:179-85. [DOI: 10.1039/c2an36385b] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
21
|
Hong M, Park SS, Do H, Jhon GJ, Suh M, Lee Y. Primo Vascular System of Murine Melanoma and Heterogeneity of Tissue Oxygenation of the Melanoma. J Acupunct Meridian Stud 2011; 4:159-63. [DOI: 10.1016/j.jams.2011.09.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2011] [Accepted: 05/03/2011] [Indexed: 11/30/2022] Open
|
22
|
Lord HL, Zhang X, Musteata FM, Vuckovic D, Pawliszyn J. In vivo solid-phase microextraction for monitoring intravenous concentrations of drugs and metabolites. Nat Protoc 2011; 6:896-924. [DOI: 10.1038/nprot.2011.329] [Citation(s) in RCA: 62] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|