1
|
Hong J, He H, Xu Y, Wang S, Luo C. An integrative temperature-controlled microfluidic system for budding yeast heat shock response analysis at the single-cell level. LAB ON A CHIP 2024. [PMID: 38915274 DOI: 10.1039/d4lc00313f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/26/2024]
Abstract
Cells can respond and adapt to complex forms of environmental change. Budding yeast is widely used as a model system for these stress response studies. In these studies, the precise control of the environment with high temporal resolution is most important. However, there is a lack of single-cell research platforms that enable precise control of the temperature and form of cell growth. This has hindered our understanding of cellular coping strategies in the face of diverse forms of temperature change. Here, we developed a novel temperature-controlled microfluidic platform that integrates a microheater (using liquid metal) and a thermocouple (liquid metal vs. conductive PDMS) on a chip. Three forms of temperature changes (step, gradient, and periodical oscillations) were realized by automated equipment. The platform has the advantages of low cost and a simple fabrication process. Moreover, we investigated the nuclear entry and exit behaviors of the transcription factor Msn2 in yeast in response to heat stress (37 °C) with different heating modes. The feasibility of this temperature-controlled platform for studying the protein dynamic behavior of yeast cells was demonstrated.
Collapse
Affiliation(s)
- Jie Hong
- The State Key Laboratory for Artificial Microstructures and Mesoscopic Physics, School of Physics, Peking University, Beijing, China.
- Center for Quantitative Biology, Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, China
| | - Hao He
- Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang, China
| | - Yinjia Xu
- The State Key Laboratory for Artificial Microstructures and Mesoscopic Physics, School of Physics, Peking University, Beijing, China.
| | - Shujing Wang
- The State Key Laboratory for Artificial Microstructures and Mesoscopic Physics, School of Physics, Peking University, Beijing, China.
- Center for Quantitative Biology, Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, China
| | - Chunxiong Luo
- The State Key Laboratory for Artificial Microstructures and Mesoscopic Physics, School of Physics, Peking University, Beijing, China.
- Center for Quantitative Biology, Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, China
- Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang, China
| |
Collapse
|
2
|
Shi L, Esfandiari L. Emerging on-chip electrokinetic based technologies for purification of circulating cancer biomarkers towards liquid biopsy: A review. Electrophoresis 2021; 43:288-308. [PMID: 34791687 DOI: 10.1002/elps.202100234] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2021] [Revised: 11/12/2021] [Accepted: 11/12/2021] [Indexed: 12/11/2022]
Abstract
Early detection of cancer can significantly reduce mortality and save lives. However, the current cancer diagnosis is highly dependent on costly, complex, and invasive procedures. Thus, a great deal of effort has been devoted to exploring new technologies based on liquid biopsy. Since liquid biopsy relies on detection of circulating biomarkers from biofluids, it is critical to isolate highly purified cancer-related biomarkers, including circulating tumor cells (CTCs), cell-free nucleic acids (cell-free DNA and cell-free RNA), small extracellular vesicles (exosomes), and proteins. The current clinical purification techniques are facing a number of drawbacks including low purity, long processing time, high cost, and difficulties in standardization. Here, we review a promising solution, on-chip electrokinetic-based methods, that have the advantage of small sample volume requirement, minimal damage to the biomarkers, rapid, and label-free criteria. We have also discussed the existing challenges of current on-chip electrokinetic technologies and suggested potential solutions that may be worthy of future studies.
Collapse
Affiliation(s)
- Leilei Shi
- Department of Electrical Engineering and Computer Science, College of Engineering and Applied Science, University of Cincinnati, Cincinnati, Ohio, USA
| | - Leyla Esfandiari
- Department of Electrical Engineering and Computer Science, College of Engineering and Applied Science, University of Cincinnati, Cincinnati, Ohio, USA.,Department of Biomedical Engineering, College of Engineering and Applied Science, University of Cincinnati, Cincinnati, Ohio, USA
| |
Collapse
|
3
|
Benton M, Hossan MR, Konari PR, Gamagedara S. Effect of Process Parameters and Material Properties on Laser Micromachining of Microchannels. MICROMACHINES 2019; 10:mi10020123. [PMID: 30769833 PMCID: PMC6413122 DOI: 10.3390/mi10020123] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/17/2019] [Revised: 02/07/2019] [Accepted: 02/12/2019] [Indexed: 11/16/2022]
Abstract
Laser micromachining has emerged as a promising technique for mass production of microfluidic devices. However, control and optimization of process parameters, and design of substrate materials are still ongoing challenges for the widespread application of laser micromachining. This article reports a systematic study on the effect of laser system parameters and thermo-physical properties of substrate materials on laser micromachining. Three dimensional transient heat conduction equation with a Gaussian laser heat source was solved using finite element based Multiphysics software COMSOL 5.2a. Large heat convection coefficients were used to consider the rapid phase transition of the material during the laser treatment. The depth of the laser cut was measured by removing material at a pre-set temperature. The grid independent analysis was performed for ensuring the accuracy of the model. The results show that laser power and scanning speed have a strong effect on the channel depth, while the level of focus of the laser beam contributes in determining both the depth and width of the channel. Higher thermal conductivity results deeper in cuts, in contrast the higher specific heat produces shallower channels for a given condition. These findings can help in designing and optimizing process parameters for laser micromachining of microfluidic devices.
Collapse
Affiliation(s)
- Matthew Benton
- Department of Engineering and Physics, University of Central Oklahoma, Edmond, OK 73034, USA.
| | - Mohammad Robiul Hossan
- Department of Engineering and Physics, University of Central Oklahoma, Edmond, OK 73034, USA.
- Center for Interdisciplinary Biomedical Education and Research, University of Central Oklahoma, Edmond, OK 73034, USA.
| | - Prashanth Reddy Konari
- Department of Engineering and Physics, University of Central Oklahoma, Edmond, OK 73034, USA.
| | - Sanjeewa Gamagedara
- Center for Interdisciplinary Biomedical Education and Research, University of Central Oklahoma, Edmond, OK 73034, USA.
- Department of Chemistry, University of Central Oklahoma, Edmond, OK 73034, USA.
| |
Collapse
|
4
|
Bayat P, Rezai P. Microfluidic curved-channel centrifuge for solution exchange of target microparticles and their simultaneous separation from bacteria. SOFT MATTER 2018; 14:5356-5363. [PMID: 29781012 DOI: 10.1039/c8sm00162f] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
One of the common operations in sample preparation is to separate specific particles (e.g. target cells, embryos or microparticles) from non-target substances (e.g. bacteria) in a fluid and to wash them into clean buffers for further processing like detection (called solution exchange in this paper). For instance, solution exchange is widely needed in preparing fluidic samples for biosensing at the point-of-care and point-of-use, but still conducted via the use of cumbersome and time-consuming off-chip analyte washing and purification techniques. Existing small-scale and handheld active and passive devices for washing particles are often limited to very low throughputs or require external sources of energy. Here, we integrated Dean flow recirculation of two fluids in curved microchannels with selective inertial focusing of target particles to develop a microfluidic centrifuge device that can isolate specific particles (as surrogates for target analytes) from bacteria and wash them into a clean buffer at high throughput and efficiency. We could process micron-size particles at a flow rate of 1 mL min-1 and achieve throughputs higher than 104 particles per second. Our results reveal that the device is capable of singleplex solution exchange of 11 μm and 19 μm particles with efficiencies of 86 ± 2% and 93 ± 0.7%, respectively. A purity of 96 ± 2% was achieved in the duplex experiments where 11 μm particles were isolated from 4 μm particles. Application of our device in biological assays was shown by performing duplex experiments where 11 μm or 19 μm particles were isolated from an Escherichia coli bacterial suspension with purities of 91-98%. We envision that our technique will have applications in point-of-care devices for simultaneous purification and solution exchange of cells and embryos from smaller substances in high-volume suspensions at high throughput and efficiency.
Collapse
Affiliation(s)
- Pouriya Bayat
- Department of Mechanical Engineering, York University, BRG 433B, 4700 Keele St, Toronto, ON M3J 1P3, Canada.
| | | |
Collapse
|
5
|
Guo J, Chen Y, Zhao L, Sun P, Li H, Zhou L, Wang X, Pu Q. A strategy to modulate the electrophoretic behavior in plastic microchips using sodium polystyrene sulfonate. J Chromatogr A 2016; 1477:132-140. [DOI: 10.1016/j.chroma.2016.11.042] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2016] [Revised: 11/21/2016] [Accepted: 11/22/2016] [Indexed: 10/20/2022]
|
6
|
Štěpánová S, Kašička V. Analysis of proteins and peptides by electromigration methods in microchips. J Sep Sci 2016; 40:228-250. [PMID: 27704694 DOI: 10.1002/jssc.201600962] [Citation(s) in RCA: 49] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2016] [Revised: 09/14/2016] [Accepted: 09/14/2016] [Indexed: 11/07/2022]
Abstract
This review presents the developments and applications of microchip electromigration methods in the separation and analysis of peptides and proteins in the period 2011-mid-2016. The developments in sample preparation and preconcentration, microchannel material, and surface treatment are described. Separations by various microchip electromigration methods (zone electrophoresis in free and sieving media, affinity electrophoresis, isotachophoresis, isoelectric focusing, electrokinetic chromatography, and electrochromatography) are demonstrated. Advances in detection methods are reported and novel applications in the areas of proteomics and peptidomics, quality control of peptide and protein pharmaceuticals, analysis of proteins and peptides in biomatrices, and determination of physicochemical parameters are shown.
Collapse
Affiliation(s)
- Sille Štěpánová
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Prague, Czech Republic
| | - Václav Kašička
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Prague, Czech Republic
| |
Collapse
|
7
|
A Novel Fabrication Technique for Liquid-Tight Microchannels by Combination of a Paraffin Polymer and a Photo-Curable Silicone Elastomer. MATERIALS 2016; 9:ma9080621. [PMID: 28773742 PMCID: PMC5509039 DOI: 10.3390/ma9080621] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/16/2016] [Revised: 07/11/2016] [Accepted: 07/25/2016] [Indexed: 11/16/2022]
Abstract
The development and growth of microfluidics has been mainly based on various novel fabrication techniques for downsizing and integration of the micro/nano components. Especially, an effective fabrication technique of three-dimensional structures still continues to be strongly required in order to improve device performance, functionality, and device packing density because the conventional lamination-based technique for integrating several two-dimensional components is not enough to satisfy the requirement. Although three-dimensional printers have a high potential for becoming an effective tool to fabricate a three-dimensional microstructure, a leak caused by the roughness of a low-precision structure made by a 3D printer is a critical problem when the microfluidic device is composed of several parts. To build a liquid-tight microchannel on such a low-precision structure, we developed a novel assembly technique in which a paraffin polymer was used as a mold for a microchannel of photo-curable silicone elastomer on a rough surface. The shape and roughness of the molded microchannel was in good agreement with the master pattern. Additionally, the seal performance of the microchannel was demonstrated by an experiment of electrophoresis in the microchannel built on a substrate which has a huge roughness and a joint.
Collapse
|
8
|
Peng X, Zhao L, Guo J, Yang S, Ding H, Wang X, Pu Q. Double-helix micro-channels on microfluidic chips for enhanced continuous on-chip derivatization followed by electrophoretic separation. Biosens Bioelectron 2015; 72:376-82. [DOI: 10.1016/j.bios.2015.05.021] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2015] [Revised: 05/04/2015] [Accepted: 05/07/2015] [Indexed: 11/15/2022]
|
9
|
Present state of microchip electrophoresis: state of the art and routine applications. J Chromatogr A 2014; 1382:66-85. [PMID: 25529267 DOI: 10.1016/j.chroma.2014.11.034] [Citation(s) in RCA: 130] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2014] [Revised: 11/07/2014] [Accepted: 11/12/2014] [Indexed: 12/20/2022]
Abstract
Microchip electrophoresis (MCE) was one of the earliest applications of the micro-total analysis system (μ-TAS) concept, whose aim is to reduce analysis time and reagent and sample consumption while increasing throughput and portability by miniaturizing analytical laboratory procedures onto a microfluidic chip. More than two decades on, electrophoresis remains the most common separation technique used in microfluidic applications. MCE-based instruments have had some commercial success and have found application in many disciplines. This review will consider the present state of MCE including recent advances in technology and both novel and routine applications in the laboratory. We will also attempt to assess the impact of MCE in the scientific community and its prospects for the future.
Collapse
|
10
|
Rapid, single-molecule assays in nano/micro-fluidic chips with arrays of closely spaced parallel channels fabricated by femtosecond laser machining. SENSORS 2014; 14:15400-14. [PMID: 25140634 PMCID: PMC4178987 DOI: 10.3390/s140815400] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/16/2014] [Revised: 08/08/2014] [Accepted: 08/18/2014] [Indexed: 12/24/2022]
Abstract
Cost-effective pharmaceutical drug discovery depends on increasing assay throughput while reducing reagent needs. To this end, we are developing an ultrasensitive, fluorescence-based platform that incorporates a nano/micro-fluidic chip with an array of closely spaced channels for parallelized optical readout of single-molecule assays. Here we describe the use of direct femtosecond laser machining to fabricate several hundred closely spaced channels on the surfaces of fused silica substrates. The channels are sealed by bonding to a microscope cover slip spin-coated with a thin film of poly(dimethylsiloxane). Single-molecule detection experiments are conducted using a custom-built, wide-field microscope. The array of channels is epi-illuminated by a line-generating red diode laser, resulting in a line focus just a few microns thick across a 500 micron field of view. A dilute aqueous solution of fluorescently labeled biomolecules is loaded into the device and fluorescence is detected with an electron-multiplying CCD camera, allowing acquisition rates up to 7 kHz for each microchannel. Matched digital filtering based on experimental parameters is used to perform an initial, rapid assessment of detected fluorescence. More detailed analysis is obtained through fluorescence correlation spectroscopy. Simulated fluorescence data is shown to agree well with experimental values.
Collapse
|
11
|
Nahavandi S, Baratchi S, Soffe R, Tang SY, Nahavandi S, Mitchell A, Khoshmanesh K. Microfluidic platforms for biomarker analysis. LAB ON A CHIP 2014; 14:1496-514. [PMID: 24663505 DOI: 10.1039/c3lc51124c] [Citation(s) in RCA: 67] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Biomarkers have been described as characteristics, most often molecular, that provide information about biological states, whether normal, pathological, or therapeutically modified. They hold great potential to assist diagnosis and prognosis, monitor disease, and assess therapeutic effectiveness. While a few biomarkers are routinely utilised clinically, these only reflect a very small percentage of all biomarkers discovered. Numerous factors contribute to the slow uptake of these new biomarkers, with challenges faced throughout the biomarker development pipeline. Microfluidics offers two important opportunities to the field of biomarkers: firstly, it can address some of these developmental obstacles, and secondly, it can provide the precise and complex platform required to bridge the gap between biomarker research and the biomarker-based analytical device market. Indeed, adoption of microfluidics has provided a new avenue for advancement, promoting clinical utilisation of both biomarkers and their analytical platforms. This review will discuss biomarkers and outline microfluidic platforms developed for biomarker analysis.
Collapse
Affiliation(s)
- Sofia Nahavandi
- Faculty of Medicine, Dentistry, & Health Sciences, The University of Melbourne, VIC 3010, Australia.
| | | | | | | | | | | | | |
Collapse
|
12
|
Microfluidic chip-based technologies: emerging platforms for cancer diagnosis. BMC Biotechnol 2013; 13:76. [PMID: 24070124 PMCID: PMC3849190 DOI: 10.1186/1472-6750-13-76] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2013] [Accepted: 09/05/2013] [Indexed: 12/20/2022] Open
Abstract
The development of early and personalized diagnostic protocols is considered the most promising avenue to decrease mortality from cancer and improve outcome. The emerging microfluidic-based analyzing platforms hold high promises to fulfill high-throughput and high-precision screening with reduced equipment cost and low analysis time, as compared to traditional bulky counterparts in bench-top laboratories. This article overviewed the potential applications of microfluidic technologies for detection and monitoring of cancer through nucleic acid and protein biomarker analysis. The implications of the technologies in cancer cytology that can provide functional personalized diagnosis were highlighted. Finally, the future niches for using microfluidic-based systems in tumor screening were briefly discussed.
Collapse
|
13
|
Nge PN, Rogers CI, Woolley AT. Advances in microfluidic materials, functions, integration, and applications. Chem Rev 2013; 113:2550-83. [PMID: 23410114 PMCID: PMC3624029 DOI: 10.1021/cr300337x] [Citation(s) in RCA: 515] [Impact Index Per Article: 46.8] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Pamela N. Nge
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602
| | - Chad I. Rogers
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602
| | - Adam T. Woolley
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602
| |
Collapse
|
14
|
Mogi K, Fujii T. A novel assembly technique with semi-automatic alignment for PDMS substrates. LAB ON A CHIP 2013; 13:1044-1047. [PMID: 23370712 DOI: 10.1039/c2lc40998d] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
This article describes a novel assembly technique with highly accurate semi-automatic alignment of polydimethylsiloxane (PDMS) substrates for microfluidic devices. The technique is realized by specific concave structures, consisting of fringes of PDMS named the "Pliant Zipper". Microchannels and the Pliant Zipper are easily fabricated together by soft lithography. Applying two Pliant Zippers on different substrates enables them to be engaged semi-automatically in the alignment position. The aligned substrates are held tightly without any external support. Highly accurate alignment was achieved manually without the micro-adjustment required in conventional techniques. The experiments presented in this article demonstrate the high accuracy of the alignment. The misalignment range of the experiments is less than 1.9 μm.
Collapse
Affiliation(s)
- Katsuo Mogi
- Institute of Industrial Science, The University of Tokyo, Fw-604, 4-6-1, Komaba, Tokyo, Japan
| | | |
Collapse
|
15
|
Nge PN, Pagaduan JV, Yu M, Woolley AT. Microfluidic chips with reversed-phase monoliths for solid phase extraction and on-chip labeling. J Chromatogr A 2012; 1261:129-35. [PMID: 22995197 PMCID: PMC3463737 DOI: 10.1016/j.chroma.2012.08.095] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2012] [Revised: 08/28/2012] [Accepted: 08/29/2012] [Indexed: 01/13/2023]
Abstract
The integration of sample preparation methods into microfluidic devices provides automation necessary for achieving complete micro total analysis systems. We have developed a technique that combines on-chip sample enrichment with fluorescence labeling and purification. Polymer monoliths made from butyl methacrylate were fabricated in cyclic olefin copolymer microdevices and used for solid phase extraction. We studied the retention of fluorophores, amino acids and proteins on these columns. The retained samples were subsequently labeled with both Alexa Fluor 488 and Chromeo P503, and unreacted dye was rinsed off the column before sample elution. Additional purification was obtained from the differential retention of proteins and fluorescent labels. A linear relation between the eluted peak areas and concentrations of on-chip labeled heat shock protein 90 samples demonstrated the utility of this method for on-chip quantitation. Our fast and simple method of simultaneously concentrating and labeling samples on-chip is compatible with miniaturization and desirable for automated analysis.
Collapse
Affiliation(s)
- Pamela N. Nge
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602
| | - Jayson V. Pagaduan
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602
| | - Ming Yu
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602
| | - Adam T. Woolley
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602
| |
Collapse
|
16
|
Garrido-Medina R, Puerta A, Rivera-Monroy Z, de Frutos M, Guttman A, Diez-Masa JC. Analysis of alpha-1-acid glycoprotein isoforms using CE-LIF with fluorescent thiol derivatization. Electrophoresis 2012; 33:1113-9. [PMID: 22539314 DOI: 10.1002/elps.201100473] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
The analysis of glycoprotein isoforms is of high interest in the biomedical field and clinical chemistry. Many studies have demonstrated that some glycoprotein isoforms could serve as biomarkers for several major diseases, such as cancers and vascular diseases, among others. Capillary zone electrophoresis (CZE) is a well-established technique to separate glycoprotein isoforms, however, it suffers from limited sensitivity when UV-Vis detection is used. On the other hand, with laser-induced fluorescence (LIF) detection, derivatization reaction to render the proteins fluorescent can destroy the resolution of the isoforms. In this work, a derivatization procedure through the thiol groups of glycoproteins using either 5-(iodoacetamide) fluorescein (5-IAF) or BODIPY iodoacetamide is presented with the model protein of alpha-1-acid glycoprotein (AGP). The derivatization process presented enabled high-resolution analysis of AGP isoforms by CZE-LIF. The derivatization procedure was successfully applied to label AGP from samples of serum and secretome of artery tissue, enabling the separation of the AGP isoforms by CE-LIF in natural samples at different concentration levels.
Collapse
|
17
|
Yang L, Li X, Li J, Yuan H, Zhao S, Xiao D. Small-angle optical deflection from collinear configuration for sensitive detection in microfluidic systems. Electrophoresis 2012; 33:1996-2004. [DOI: 10.1002/elps.201100442] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Affiliation(s)
- Li Yang
- College of Chemistry and College of Chemical Engineering; Sichuan University; Chengdu; P. R. China
| | - Xiangtang Li
- College of Chemistry and College of Chemical Engineering; Sichuan University; Chengdu; P. R. China
| | - Jing Li
- College of Chemistry and College of Chemical Engineering; Sichuan University; Chengdu; P. R. China
| | - Hongyan Yuan
- College of Chemistry and College of Chemical Engineering; Sichuan University; Chengdu; P. R. China
| | - Shulin Zhao
- College of Chemistry and Chemical Engineering; Guangxi Normal University; Guilin; P. R. China
| | - Dan Xiao
- College of Chemistry and College of Chemical Engineering; Sichuan University; Chengdu; P. R. China
| |
Collapse
|
18
|
Yi L, Chen YX, Lin PC, Schröder H, Niemeyer CM, Wu YW, Goody RS, Triola G, Waldmann H. Direct immobilization of oxyamine-modified proteins from cell lysates. Chem Commun (Camb) 2012; 48:10829-31. [DOI: 10.1039/c2cc35237k] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|