1
|
Hochstetter A. Lab-on-a-Chip Technologies for the Single Cell Level: Separation, Analysis, and Diagnostics. MICROMACHINES 2020; 11:E468. [PMID: 32365567 PMCID: PMC7281269 DOI: 10.3390/mi11050468] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/08/2020] [Revised: 04/25/2020] [Accepted: 04/25/2020] [Indexed: 12/14/2022]
Abstract
In the last three decades, microfluidics and its applications have been on an exponential rise, including approaches to isolate rare cells and diagnose diseases on the single-cell level. The techniques mentioned herein have already had significant impacts in our lives, from in-the-field diagnosis of disease and parasitic infections, through home fertility tests, to uncovering the interactions between SARS-CoV-2 and their host cells. This review gives an overview of the field in general and the most notable developments of the last five years, in three parts: 1. What can we detect? 2. Which detection technologies are used in which setting? 3. How do these techniques work? Finally, this review discusses potentials, shortfalls, and an outlook on future developments, especially in respect to the funding landscape and the field-application of these chips.
Collapse
Affiliation(s)
- Axel Hochstetter
- Experimentalphysik, Universität des Saarlandes, D-66123 Saarbrücken, Germany
| |
Collapse
|
2
|
Fukuyama Y, Yasuda N, Sugimoto K, Kimura S. X-ray diffraction measurement of a single nanometre-sized particle levitated in air by an optical-trap sample holder. JOURNAL OF SYNCHROTRON RADIATION 2020; 27:67-74. [PMID: 31868738 DOI: 10.1107/s1600577519013651] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2019] [Accepted: 10/07/2019] [Indexed: 06/10/2023]
Abstract
A single-beam optical-trap sample holder for X-ray diffraction measurements with synchrotron radiation has been developed. The sample holder was used to obtain an X-ray diffraction image of a single ZnO particle levitated in air, without mechanical contact, by the optical gradient force exerted by a focused laser beam. The diffraction image showed a Debye ring pattern, which was similar to a powder diffraction pattern of an assemblage of ZnO particles. While the ZnO particle is held by the optical trap in air, it rotates irregularly. Therefore, the Debye ring pattern of the ZnO particle can be clearly obtained even if the ZnO particle is a single grain. Lattice parameters and crystallite size of the single ZnO particle were determined simultaneously. The lattice parameters were determined to be a = 3.2505 ± 0.0005 Å and c = 5.207 ± 0.006 Å, which are consistent with those of the assemblage of ZnO particles. The crystallite size determined by the Scherrer method was 193.4 ± 26.2 nm.
Collapse
Affiliation(s)
- Yoshimitsu Fukuyama
- Center for Synchrotron Radiation Research, Japan Synchrotron Radiation Research Institute (JASRI), 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198, Japan
| | - Nobuhiro Yasuda
- Center for Synchrotron Radiation Research, Japan Synchrotron Radiation Research Institute (JASRI), 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198, Japan
| | - Kunihisa Sugimoto
- Center for Synchrotron Radiation Research, Japan Synchrotron Radiation Research Institute (JASRI), 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198, Japan
| | - Shigeru Kimura
- Center for Synchrotron Radiation Research, Japan Synchrotron Radiation Research Institute (JASRI), 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198, Japan
| |
Collapse
|
3
|
Three-dimensional optical trapping and orientation of microparticles for coherent X-ray diffraction imaging. Proc Natl Acad Sci U S A 2019; 116:4018-4024. [PMID: 30765527 DOI: 10.1073/pnas.1720785116] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023] Open
Abstract
Optical trapping has been implemented in many areas of physics and biology as a noncontact sample manipulation technique to study the structure and dynamics of nano- and mesoscale objects. It provides a unique approach for manipulating microscopic objects without inducing undesired changes in structure. Combining optical trapping with hard X-ray microscopy techniques, such as coherent diffraction imaging and crystallography, provides a nonperturbing environment where electronic and structural dynamics of an individual particle in solution can be followed in situ. It was previously shown that optical trapping allows the manipulation of micrometer-sized objects for X-ray fluorescence imaging. However, questions remain over the ability of optical trapping to position objects for X-ray diffraction measurements, which have stringent requirements for angular stability. Our work demonstrates that dynamic holographic optical tweezers are capable of manipulating single micrometer-scale anisotropic particles in a microfluidic environment with the precision and stability required for X-ray Bragg diffraction experiments-thus functioning as an "optical goniometer." The methodology can be extended to a variety of X-ray experiments and the Bragg coherent diffractive imaging of individual particles in solution, as demonstrated here, will be markedly enhanced with the advent of brighter, coherent X-ray sources.
Collapse
|
4
|
Nicolas JD, Hagemann J, Sprung M, Salditt T. The optical stretcher as a tool for single-particle X-ray imaging and diffraction. JOURNAL OF SYNCHROTRON RADIATION 2018; 25:1196-1205. [PMID: 29979182 DOI: 10.1107/s1600577518006574] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2018] [Accepted: 04/27/2018] [Indexed: 06/08/2023]
Abstract
For almost half a century, optical tweezers have successfully been used to micromanipulate micrometre and sub-micrometre-sized particles. However, in recent years it has been shown experimentally that, compared with single-beam traps, the use of two opposing and divergent laser beams can be more suitable in studying the elastic properties of biological cells and vesicles. Such a configuration is termed an optical stretcher due to its capability of applying high deforming forces on biological objects such as cells. In this article the experimental capabilities of an optical stretcher as a potential sample delivery system for X-ray diffraction and imaging studies at synchrotrons and X-ray free-electron laser (FEL) facilites are demonstrated. To highlight the potential of the optical stretcher its micromanipulation capabilities have been used to image polymer beads and label biological cells. Even in a non-optimized configuration based on a commercially available optical stretcher system, X-ray holograms could be recorded from different views on a biological cell and the three-dimensional phase of the cell could be reconstructed. The capability of the setup to deform cells at higher laser intensities in combination with, for example, X-ray diffraction studies could furthermore lead to interesting studies that couple structural parameters to elastic properties. By means of high-throughput screening, the optical stretcher could become a useful tool in X-ray studies employing synchrotron radiation, and, at a later stage, femtosecond X-ray pulses delivered by X-ray free-electron lasers.
Collapse
Affiliation(s)
- Jan David Nicolas
- Georg-August-Universität Göttingen, Institut für Röntgenphysik, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
| | - Johannes Hagemann
- Deutsches Elektronen-Synchrotron, Notkestraße. 85, 22607 Hamburg, Germany
| | - Michael Sprung
- Deutsches Elektronen-Synchrotron, Notkestraße. 85, 22607 Hamburg, Germany
| | - Tim Salditt
- Georg-August-Universität Göttingen, Institut für Röntgenphysik, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
| |
Collapse
|
5
|
Vergucht E, Brans T, Beunis F, Garrevoet J, Bauters S, De Rijcke M, Deruytter D, Janssen C, Riekel C, Burghammer M, Vincze L. Methodological challenges of optical tweezers-based X-ray fluorescence imaging of biological model organisms at synchrotron facilities. JOURNAL OF SYNCHROTRON RADIATION 2015; 22:1096-1105. [PMID: 26134817 DOI: 10.1107/s1600577515009534] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2015] [Accepted: 05/19/2015] [Indexed: 06/04/2023]
Abstract
Recently, a radically new synchrotron radiation-based elemental imaging approach for the analysis of biological model organisms and single cells in their natural in vivo state was introduced. The methodology combines optical tweezers (OT) technology for non-contact laser-based sample manipulation with synchrotron radiation confocal X-ray fluorescence (XRF) microimaging for the first time at ESRF-ID13. The optical manipulation possibilities and limitations of biological model organisms, the OT setup developments for XRF imaging and the confocal XRF-related challenges are reported. In general, the applicability of the OT-based setup is extended with the aim of introducing the OT XRF methodology in all research fields where highly sensitive in vivo multi-elemental analysis is of relevance at the (sub)micrometre spatial resolution level.
Collapse
Affiliation(s)
- Eva Vergucht
- Department of Analytical Chemistry, Ghent University, Krijgslaan 281, Ghent 9000, Belgium
| | - Toon Brans
- Department of Electronics and Information Systems, Ghent University, Sint-Pietersnieuwstraat 41, Ghent 9000, Belgium
| | - Filip Beunis
- Department of Electronics and Information Systems, Ghent University, Sint-Pietersnieuwstraat 41, Ghent 9000, Belgium
| | - Jan Garrevoet
- Department of Analytical Chemistry, Ghent University, Krijgslaan 281, Ghent 9000, Belgium
| | - Stephen Bauters
- Department of Analytical Chemistry, Ghent University, Krijgslaan 281, Ghent 9000, Belgium
| | - Maarten De Rijcke
- Laboratory of Environmental Toxicology and Aquatic Ecology, Ghent University, Jozef Plateaustraat 22, Ghent 9000, Belgium
| | - David Deruytter
- Laboratory of Environmental Toxicology and Aquatic Ecology, Ghent University, Jozef Plateaustraat 22, Ghent 9000, Belgium
| | - Colin Janssen
- Laboratory of Environmental Toxicology and Aquatic Ecology, Ghent University, Jozef Plateaustraat 22, Ghent 9000, Belgium
| | - Christian Riekel
- European Synchrotron Radiation Facility, 71 avenue des Martyrs, Grenoble 38000, France
| | - Manfred Burghammer
- Department of Analytical Chemistry, Ghent University, Krijgslaan 281, Ghent 9000, Belgium
| | - Laszlo Vincze
- Department of Analytical Chemistry, Ghent University, Krijgslaan 281, Ghent 9000, Belgium
| |
Collapse
|
6
|
In vivo X-ray elemental imaging of single cell model organisms manipulated by laser-based optical tweezers. Sci Rep 2015; 5:9049. [PMID: 25762511 PMCID: PMC4356986 DOI: 10.1038/srep09049] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2014] [Accepted: 01/29/2015] [Indexed: 11/08/2022] Open
Abstract
We report on a radically new elemental imaging approach for the analysis of biological model organisms and single cells in their natural, in vivo state. The methodology combines optical tweezers (OT) technology for non-contact, laser-based sample manipulation with synchrotron radiation confocal X-ray fluorescence (XRF) microimaging for the first time. The main objective of this work is to establish a new method for in vivo elemental imaging in a two-dimensional (2D) projection mode in free-standing biological microorganisms or single cells, present in their aqueous environment. Using the model organism Scrippsiella trochoidea, a first proof of principle experiment at beamline ID13 of the European Synchrotron Radiation Facility (ESRF) demonstrates the feasibility of the OT XRF methodology, which is applied to study mixture toxicity of Cu-Ni and Cu-Zn as a result of elevated exposure. We expect that the new OT XRF methodology will significantly contribute to the new trend of investigating microorganisms at the cellular level with added in vivo capability.
Collapse
|
7
|
Grad M, Bigelow AW, Garty G, Attinger D, Brenner DJ. Optofluidic cell manipulation for a biological microbeam. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2013; 84:014301. [PMID: 23387672 PMCID: PMC3562345 DOI: 10.1063/1.4774043] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2012] [Accepted: 12/11/2012] [Indexed: 06/01/2023]
Abstract
This paper describes the fabrication and integration of light-induced dielectrophoresis for cellular manipulation in biological microbeams. An optoelectronic tweezers (OET) cellular manipulation platform was designed, fabricated, and tested at Columbia University's Radiological Research Accelerator Facility (RARAF). The platform involves a light induced dielectrophoretic surface and a microfluidic chamber with channels for easy input and output of cells. The electrical conductivity of the particle-laden medium was optimized to maximize the dielectrophoretic force. To experimentally validate the operation of the OET device, we demonstrate UV-microspot irradiation of cells containing green fluorescent protein (GFP) tagged DNA single-strand break repair protein, targeted in suspension. We demonstrate the optofluidic control of single cells and groups of cells before, during, and after irradiation. The integration of optofluidic cellular manipulation into a biological microbeam enhances the facility's ability to handle non-adherent cells such as lymphocytes. To the best of our knowledge, this is the first time that OET cell handling is successfully implemented in a biological microbeam.
Collapse
Affiliation(s)
- Michael Grad
- Department of Mechanical Engineering, Columbia University, New York, New York 10027, USA.
| | | | | | | | | |
Collapse
|