1
|
Azuaje-Hualde E, Alonso-Cabrera JA, de Pancorbo MM, Benito-Lopez F, Basabe-Desmonts L. Integration of secreted signaling molecule sensing on cell monitoring platforms: a critical review. Anal Bioanal Chem 2024:10.1007/s00216-024-05435-1. [PMID: 39048740 DOI: 10.1007/s00216-024-05435-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2024] [Revised: 06/10/2024] [Accepted: 06/28/2024] [Indexed: 07/27/2024]
Abstract
Monitoring cell secretion in complex microenvironments is crucial for understanding cellular behavior and advancing physiological and pathological research. While traditional cell culture methods, including organoids and spheroids, provide valuable models, real-time monitoring of cell secretion of signaling molecules remains challenging. Integrating advanced monitoring technologies into these systems often disrupts the delicate balance of the microenvironment, making it difficult to achieve sensitivity and specificity. This review explored recent strategies for integrating the monitoring of cell secretion of signaling molecules, crucial for understanding and replicating cell microenvironments, within cell culture platforms, addressing challenges such as non-adherent cell models and the focus on single-cell methodologies. We highlight advancements in biosensors, microfluidics, and three-dimensional culture methods, and discuss their potential to enhance real-time, multiplexed cell monitoring. By examining the advantages, limitations, and future prospects of these technologies, we aim to contribute to the development of integrated systems that facilitate comprehensive cell monitoring, ultimately advancing biological research and pharmaceutical development.
Collapse
Affiliation(s)
- Enrique Azuaje-Hualde
- Microfluidics Cluster UPV/EHU, BIOMICs Microfluidics Group, Lascaray Research Center, University of the Basque Country UPV/EHU, Vitoria-Gasteiz, Spain
| | - Juncal A Alonso-Cabrera
- Microfluidics Cluster UPV/EHU, BIOMICs Microfluidics Group, Lascaray Research Center, University of the Basque Country UPV/EHU, Vitoria-Gasteiz, Spain
| | - Marian M de Pancorbo
- BIOMICs Research Group, Lascaray Research Center, University of the Basque Country UPV/EHU, Vitoria-Gasteiz, Spain
| | - Fernando Benito-Lopez
- Microfluidics Cluster UPV/EHU, Analytical Microsystems & Materials for Lab-on-a-Chip (AMMa-LOAC) Group, Analytical Chemistry Department, University of the Basque Country UPV/EHU, Leioa, Spain.
- Microfluidics Cluster UPV/EHU, Bioaraba Health Research Institute, Vitoria-Gasteiz, Spain.
- Basque Foundation of Science, IKERBASQUE, María Díaz Haroko Kalea, 3, 48013, Bilbao, Spain.
| | - Lourdes Basabe-Desmonts
- Microfluidics Cluster UPV/EHU, BIOMICs Microfluidics Group, Lascaray Research Center, University of the Basque Country UPV/EHU, Vitoria-Gasteiz, Spain.
- Microfluidics Cluster UPV/EHU, Bioaraba Health Research Institute, Vitoria-Gasteiz, Spain.
- Basque Foundation of Science, IKERBASQUE, María Díaz Haroko Kalea, 3, 48013, Bilbao, Spain.
| |
Collapse
|
2
|
Expósito JR, Mejuto I, Catalá M. Detection of active cell death markers in rehydrated lichen thalli and the involvement of nitrogen monoxide (NO). Symbiosis 2020. [DOI: 10.1007/s13199-020-00727-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
3
|
Ruvalcaba-Cardenas AD, Gomez RAR, Khoshmanesh K, Tovar-Lopez FJ. Magnetic actuation and deformation of a soft shuttle. BIOMICROFLUIDICS 2020; 14:034103. [PMID: 32477442 PMCID: PMC7237223 DOI: 10.1063/5.0008176] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Accepted: 05/05/2020] [Indexed: 05/12/2023]
Abstract
Here, we describe the magnetic actuation of soft shuttles for open-top microfluidic applications. The system is comprised of two immiscible liquids, including glycerol as the soft shuttle and a suspension of iron powder in sucrose solution as the magnetic drop. Permanent magnets assembled on 3D printed motorized actuators were used for the actuation of the magnetic drop, enabling the glycerol shuttle to be propelled along customized linear, circular, and sinusoidal paths. The dynamics of the hybrid shuttle-magnetic drop system was governed by the magnetic force, the friction at the interface of the shuttle and the substrate, and the surface tension at the interface of the shuttle and the magnetic drop. Increasing the magnetic force leads to the localized deformation of the shuttle and eventually the full extraction of the magnetic drop. The versatility of the system was demonstrated through the propelling of the shuttle across a rough surface patterned with microfabricated barriers as well as taking advantage of the optical properties of the shuttle for the magnification and translation of microscale characters patterned on a planar surface. The integration of the system with current electrowetting actuation mechanisms enables the highly controlled motion of the magnetic drop on the surface of a moving shuttle. The simplicity, versatility, and controllability of the system provide opportunities for various fluid manipulation, sample preparation, and analysis for a range of chemical, biochemical, and biological applications.
Collapse
Affiliation(s)
- Ana Daysi Ruvalcaba-Cardenas
- School of Engineering, RMIT University, Melbourne, Victoria 3000, Australia
- Authors to whom correspondence should be addressed:; ; and
| | | | - Khashayar Khoshmanesh
- School of Engineering, RMIT University, Melbourne, Victoria 3000, Australia
- Authors to whom correspondence should be addressed:; ; and
| | - Francisco J. Tovar-Lopez
- School of Engineering, RMIT University, Melbourne, Victoria 3000, Australia
- Authors to whom correspondence should be addressed:; ; and
| |
Collapse
|
4
|
Varma S, Voldman J. Caring for cells in microsystems: principles and practices of cell-safe device design and operation. LAB ON A CHIP 2018; 18:3333-3352. [PMID: 30324208 PMCID: PMC6254237 DOI: 10.1039/c8lc00746b] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Microfluidic device designers and users continually question whether cells are 'happy' in a given microsystem or whether they are perturbed by micro-scale technologies. This issue is normally brought up by engineers building platforms, or by external reviewers (academic or commercial) comparing multiple technological approaches to a problem. Microsystems can apply combinations of biophysical and biochemical stimuli that, although essential to device operation, may damage cells in complex ways. However, assays to assess the impact of microsystems upon cells have been challenging to conduct and have led to subjective interpretation and evaluation of cell stressors, hampering development and adoption of microsystems. To this end, we introduce a framework that defines cell health, describes how device stimuli may stress cells, and contrasts approaches to measure cell stress. Importantly, we provide practical guidelines regarding device design and operation to minimize cell stress, and recommend a minimal set of quantitative assays that will enable standardization in the assessment of cell health in diverse devices. We anticipate that as microsystem designers, reviewers, and end-users enforce such guidelines, we as a community can create a set of essential principles that will further the adoption of such technologies in clinical, translational and commercial applications.
Collapse
Affiliation(s)
- Sarvesh Varma
- Department of Electrical Engineering and Computer Science
, Massachusetts Institute of Technology
,
77 Massachusetts Avenue, Room 36-824
, Cambridge
, USA
.
; Fax: +617 258 5846
; Tel: +617 253 1583
| | - Joel Voldman
- Department of Electrical Engineering and Computer Science
, Massachusetts Institute of Technology
,
77 Massachusetts Avenue, Room 36-824
, Cambridge
, USA
.
; Fax: +617 258 5846
; Tel: +617 253 1583
| |
Collapse
|
5
|
Rane AS, Rutkauskaite J, deMello A, Stavrakis S. High-Throughput Multi-parametric Imaging Flow Cytometry. Chem 2017. [DOI: 10.1016/j.chempr.2017.08.005] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
6
|
Effects of Nano-CeO₂ with Different Nanocrystal Morphologies on Cytotoxicity in HepG2 Cells. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2015; 12:10806-19. [PMID: 26404340 PMCID: PMC4586644 DOI: 10.3390/ijerph120910806] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2015] [Revised: 08/17/2015] [Accepted: 08/20/2015] [Indexed: 12/27/2022]
Abstract
Cerium oxide nanoparticles (nano-CeO2) have been reported to cause damage and apoptosis in human primary hepatocytes. Here, we compared the toxicity of three types of nano-CeO2 with different nanocrystal morphologies (cube-, octahedron-, and rod-like crystals) in human hepatocellular carcinoma cells (HepG2). The cells were treated with the nano-CeO2 at various concentrations (6.25, 12.5, 25, 50, 100 μg/mL). The crystal structure, size and morphology of nano-CeO2 were investigated by X-ray diffractometry and transmission electron microscopy. The specific surface area was detected using the Brunauer, Emmet and Teller method. The cellular morphological and internal structure were observed by microscopy; apoptotic alterations were measured using flow cytometry; nuclear DNA, mitochondrial membrane potential (MMP), reactive oxygen species (ROS) and glutathione (GSH) in HepG2 cells were measured using high content screening technology. The scavenging ability of hydroxyl free radicals and the redox properties of the nano-CeO2 were measured by square-wave voltammetry and temperature-programmed-reduction methods. All three types of nano-CeO2 entered the HepG2 cells, localized in the lysosome and cytoplasm, altered cellular shape, and caused cytotoxicity. The nano-CeO2 with smaller specific surface areas induced more apoptosis, caused an increase in MMP, ROS and GSH, and lowered the cell’s ability to scavenge hydroxyl free radicals and antioxidants. In this work, our data demonstrated that compared with cube-like and octahedron-like nano-CeO2, the rod-like nano-CeO2 has lowest toxicity to HepG2 cells owing to its larger specific surface areas.
Collapse
|
7
|
Caviglia C, Zór K, Montini L, Tilli V, Canepa S, Melander F, Muhammad HB, Carminati M, Ferrari G, Raiteri R, Heiskanen A, Andresen TL, Emnéus J. Impedimetric toxicity assay in microfluidics using free and liposome-encapsulated anticancer drugs. Anal Chem 2015; 87:2204-12. [PMID: 25582124 DOI: 10.1021/ac503621d] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
In this work, we have developed a microfluidic cytotoxicity assay for a cell culture and detection platform, which enables both fluid handling and electrochemical/optical detection. The cytotoxic effect of anticancer drugs doxorubicin (DOX), oxaliplatin (OX) as well as OX-loaded liposomes, developed for targeted drug delivery, was evaluated using real-time impedance monitoring. The time-dependent effect of DOX on HeLa cells was monitored and found to have a delayed onset of cytotoxicity in microfluidics compared with static culture conditions based on data obtained in our previous study. The result of a fluorescent microscopic annexin V/propidium iodide assay, performed in microfluidics, confirmed the outcome of the real-time impedance assay. In addition, the response of HeLa cells to OX-induced cytotoxicity proved to be slower than toxicity induced by DOX. A difference in the time-dependent cytotoxic response of fibrosarcoma cells (HT1080) to free OX and OX-loaded liposomes was observed and attributed to incomplete degradation of the liposomes, which results in lower drug availability. The matrix metalloproteinase (MMP)-dependent release of OX from OX-loaded liposomes was also confirmed using laryngopharynx carcinoma cells (FaDu). The comparison and the observed differences between the cytotoxic effects under microfluidic and static conditions highlight the importance of comparative studies as basis for implementation of microfluidic cytotoxic assays.
Collapse
Affiliation(s)
- Claudia Caviglia
- Department of Micro- and Nanotechnology, Technical University of Denmark , DK-2800 Kongens Lyngby, Denmark
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Real-time quantification of protein expression and translocation at individual cell resolution using imaging-dish-based live cell array. Anal Bioanal Chem 2014; 406:7085-101. [PMID: 25258284 DOI: 10.1007/s00216-014-8157-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2014] [Revised: 08/19/2014] [Accepted: 09/02/2014] [Indexed: 01/19/2023]
Abstract
Cell populations represent intrinsically heterogeneous systems with a high level of spatiotemporal complexity. Monitoring and understanding cell-to-cell diversity is essential for the research and application of intra- and interpopulation variations. Optical analysis of live cells is challenging since both adherent and nonadherent cells change their spatial location. However, most currently available single-cell techniques do not facilitate treatment and monitoring of the same live cells over time throughout multistep experiments. An imaging-dish-based live cell array (ID-LCA) has been developed and produced for cell handling, culturing, and imaging of numerous live cells. The dish is composed of an array of pico scale cavities-pico wells (PWs) embossed on its glass bottom. Cells are seeded, cultured, treated, and spatiotemporally measured on the ID-LCA, while each cell or small group of cells are locally constrained in the PWs. Finally, predefined cells can be retrieved for further evaluation. Various types of ID-LCAs were used in this proof-of-principle work, to demonstrate on-ID-LCA transfection of fluorescently tagged chimeric proteins, as well as the detection and kinetic analysis of their induced translocation. High variability was evident within cell populations with regard to protein expression levels as well as the extent and dynamics of protein redistribution. The association of these parameters with cell morphology and functional parameters was examined. Both the new methodology and the device facilitate research of the translocation process at individual cell resolution within large populations and thus, can potentially be used in high-throughput fashion.
Collapse
|
9
|
Halldorsson S, Lucumi E, Gómez-Sjöberg R, Fleming RMT. Advantages and challenges of microfluidic cell culture in polydimethylsiloxane devices. Biosens Bioelectron 2014; 63:218-231. [PMID: 25105943 DOI: 10.1016/j.bios.2014.07.029] [Citation(s) in RCA: 572] [Impact Index Per Article: 57.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2014] [Revised: 07/03/2014] [Accepted: 07/12/2014] [Indexed: 02/06/2023]
Abstract
Culture of cells using various microfluidic devices is becoming more common within experimental cell biology. At the same time, a technological radiation of microfluidic cell culture device designs is currently in progress. Ultimately, the utility of microfluidic cell culture will be determined by its capacity to permit new insights into cellular function. Especially insights that would otherwise be difficult or impossible to obtain with macroscopic cell culture in traditional polystyrene dishes, flasks or well-plates. Many decades of heuristic optimization have gone into perfecting conventional cell culture devices and protocols. In comparison, even for the most commonly used microfluidic cell culture devices, such as those fabricated from polydimethylsiloxane (PDMS), collective understanding of the differences in cellular behavior between microfluidic and macroscopic culture is still developing. Moving in vitro culture from macroscopic culture to PDMS based devices can come with unforeseen challenges. Changes in device material, surface coating, cell number per unit surface area or per unit media volume may all affect the outcome of otherwise standard protocols. In this review, we outline some of the advantages and challenges that may accompany a transition from macroscopic to microfluidic cell culture. We focus on decisive factors that distinguish macroscopic from microfluidic cell culture to encourage a reconsideration of how macroscopic cell culture principles might apply to microfluidic cell culture.
Collapse
Affiliation(s)
- Skarphedinn Halldorsson
- Center for Systems Biology and Biomedical Center, University of Iceland, Sturlugata 8, Reykjavik, Iceland
| | - Edinson Lucumi
- Luxembourg Centre for Systems Biomedicine, University of Luxembourg, 7 avenue des Hauts-Fourneaux, Esch-sur-Alzette, Luxembourg
| | - Rafael Gómez-Sjöberg
- Engineering Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA, United States of America
| | - Ronan M T Fleming
- Luxembourg Centre for Systems Biomedicine, University of Luxembourg, 7 avenue des Hauts-Fourneaux, Esch-sur-Alzette, Luxembourg.
| |
Collapse
|
10
|
Khanal G, Hiemstra S, Pappas D. Probing hypoxia-induced staurosporine resistance in prostate cancer cells with a microfluidic culture system. Analyst 2014; 139:3274-80. [PMID: 24479128 PMCID: PMC4043951 DOI: 10.1039/c3an02324a] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
A microfluidic system for cell culture and drug response studies was developed to elucidate the effects of hypoxia on drug susceptibility. Drug response studies were performed in prostate cancer cells and Ramos B cells under normoxic and hypoxic conditions. A vacuum actuated microfluidic culture device was used for cell culture and PC3 cells were cultured in the chip up to 16 hours. Cells were treated with several concentrations of staurosporine and apoptosis was assayed using the fluorescent probes MitoTracker Deep Red and Annexin-V. For hypoxic samples, the chip was placed in a hypoxia chamber and pre-conditioned at <1% oxygen before inducing the cells with staurosporine. Cells exposed to 2 μM staurosporine were 32% ± 10% apoptotic under normoxic conditions but only 1.5% ± 12% apoptotic under hypoxic conditions. As little as 1 hour of hypoxic preconditioning increased drug resistance. Cell apoptosis correlated with drug dose, although in each case hypoxia reduced the apoptotic fraction significantly. Given the rapid nature of cell adaptation to hypoxia, this chip and analysis approach can be used to identify compounds that can induce cell death in hypoxic tumor cells rapidly.
Collapse
Affiliation(s)
- Grishma Khanal
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX 79409-1061, USA.
| | | | | |
Collapse
|
11
|
Mart RJ, Errington RJ, Watkins CL, Chappell SC, Wiltshire M, Jones AT, Smith PJ, Allemann RK. BH3 helix-derived biophotonic nanoswitches regulate cytochrome c release in permeabilised cells. MOLECULAR BIOSYSTEMS 2014; 9:2597-603. [PMID: 23942570 DOI: 10.1039/c3mb70246d] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Dynamic physical interactions between proteins underpin all key cellular processes and are a highly attractive area for the development of research tools and medicines. Protein-protein interactions frequently involve α-helical structures, but peptides matching the sequences of these structures usually do not fold correctly in isolation. Therefore, much research has focused on the creation of small peptides that adopt stable α-helical structures even in the absence of their intended protein targets. We show that short peptides alkylated with azobenzene crosslinkers can be used to photo-stimulate mitochondrial membrane depolarization and cytochrome c release in permeabilised cells, the initial events of the intrinsic apoptosis pathway.
Collapse
Affiliation(s)
- Robert J Mart
- School of Chemistry, Cardiff University, Main Building, Park Place, Cardiff CF10 3AT, UK.
| | | | | | | | | | | | | | | |
Collapse
|
12
|
Javanmard M, Emaminejad S, Gupta C, Provine J, Davis R, Howe R. Depletion of cells and abundant proteins from biological samples by enhanced dielectrophoresis. SENSORS AND ACTUATORS. B, CHEMICAL 2014; 193:918-924. [PMID: 26924893 PMCID: PMC4765371 DOI: 10.1016/j.snb.2013.11.100] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Platforms that are sensitive and specific enough to assay low-abundance protein biomarkers, in a high throughput multiplex format, within a complex biological fluid specimen, are necessary to enable protein biomarker based diagnostics for diseases such as cancer. The signal from an assay for a low-abundance protein biomarker in a biological fluid sample like blood is typically buried in a background that arises from the presence of blood cells and from high-abundance proteins that make up 90% of the assayed protein mass. We present an automated on-chip platform for the depletion of cells and highly abundant serum proteins in blood. Our platform consists of two components, the first of which is a microfluidic mixer that mixes beads containing antibodies against the highly abundant proteins in the whole blood. This complex mixture (consisting of beads, cells, and serum proteins) is then injected into the second component of our microfluidic platform, which comprises a filter trench to capture all the cells and the beads. The size-based trapping of the cells and beads into the filter trench is significantly enhanced by leveraging additional negative dielectrophoretic forces to push the micron sized particles (cells and beads which have captured the highly abundant proteins) down into the trench, allowing the serum proteins of lower abundance to flow through. In general, dielectrophoresis using bare electrodes is incapable of producing forces beyond the low piconewton range that tend to be insufficient for separation applications. However, by using electrodes passivated with atomic layer deposition, we demonstrate the application of enhanced negative DEP electrodes together with size-based flltration induced by the filter trench, to deplete 100% of the micron sized particles in the mixture.
Collapse
Affiliation(s)
- M. Javanmard
- Stanford Genome Technology Center, Stanford University, Stanford, CA, USA
| | - S. Emaminejad
- Stanford Genome Technology Center, Stanford University, Stanford, CA, USA
- Electrical Engineering Department, Stanford University, Stanford, CA, USA
| | - C. Gupta
- Electrical Engineering Department, Stanford University, Stanford, CA, USA
| | - J. Provine
- Electrical Engineering Department, Stanford University, Stanford, CA, USA
| | - R.W. Davis
- Stanford Genome Technology Center, Stanford University, Stanford, CA, USA
| | - R.T. Howe
- Electrical Engineering Department, Stanford University, Stanford, CA, USA
| |
Collapse
|
13
|
Microfluidic chip integrated with flexible PDMS-based electrochemical cytosensor for dynamic analysis of drug-induced apoptosis on HeLa cells. Biosens Bioelectron 2014; 51:97-102. [DOI: 10.1016/j.bios.2013.07.025] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2013] [Revised: 06/06/2013] [Accepted: 07/12/2013] [Indexed: 12/26/2022]
|
14
|
Zheng XT, Yu L, Li P, Dong H, Wang Y, Liu Y, Li CM. On-chip investigation of cell-drug interactions. Adv Drug Deliv Rev 2013; 65:1556-74. [PMID: 23428898 DOI: 10.1016/j.addr.2013.02.001] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2012] [Revised: 01/23/2013] [Accepted: 02/06/2013] [Indexed: 12/17/2022]
Abstract
Investigation of cell-drug interaction is of great importance in drug discovery but continues to pose significant challenges to develop robust, fast and high-throughput methods for pharmacologically profiling of potential drugs. Recently, cell chips have emerged as a promising technology for drug discovery/delivery, and their miniaturization and flow-through operation significantly reduce sample consumption while dramatically improving the throughput, reliability, resolution and sensitivity. Herein we review various types of miniaturized cell chips used in investigation of cell-drug interactions. The design and fabrication of cell chips including material selection, surface modification, cell trapping/patterning, concentration gradient generation and mimicking of in vivo environment are presented. Recent advances of on-chip investigations of cell-drug interactions, in particular the high-throughput screening, cell sorting, cytotoxicity testing, drug resistance analysis and pharmacological profiling are examined and discussed. It is expected that this survey can provide thoughtful basics and important applications of on-chip investigations of cell-drug interactions, thus greatly promoting research and development interests in this area.
Collapse
|
15
|
Wlodkowic D, Skommer J, Akagi J, Fujimura Y, Takeda K. Multiparameter analysis of apoptosis using lab-on-a-chip flow cytometry. CURRENT PROTOCOLS IN CYTOMETRY 2013; 66:9.42.1-9.42.15. [PMID: 24510726 DOI: 10.1002/0471142956.cy0942s66] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The age of microfluidic flow cytometry (µFCM) is fast becoming a reality. One of the most exciting applications of miniaturized chip-based cytometers is multivariate analysis using sampling volumes as small as 10 µl while matching the multiparameter data collection of conventional flow cytometers. We outline several innovative protocols for analyzing caspase-dependent cell death and cell cycle (DNA-content) profile using a fully integrated microfluidic flow cytometry system, Fishman-R. The first protocol describes the use of a new plasma membrane-permeability marker, DRAQ7, and the fluorogenic caspase substrate PhiPhiLux to track caspase activation during programmed cell death. Also outlined is the use of DRAQ7 fluorochrome in conjunction with the mitochondrial membrane potential-sensitive probe TMRM to track dissipation of inner mitochondrial cross-membrane potential. Another protocol adds the ability to measure dissipation of mitochondrial inner membrane potential (using TMRM probe) in relation to the cell cycle profile (using DRAQ5 probe) in living leukemic cells. Finally, we describe the combined use of fluorogenic caspases substrate PhiPhiLux with DRAQ5 probe to measure caspase activation in relation to the cell cycle profile in living tumor cells.
Collapse
Affiliation(s)
- Donald Wlodkowic
- The BioMEMS Research Group, School of Chemical Sciences, University of Auckland, Auckland, New Zealand
- The BioMEMS Research Group, School of Applied Sciences, RMIT University, Melbourne, Australia
| | - Joanna Skommer
- The BioMEMS Research Group, School of Chemical Sciences, University of Auckland, Auckland, New Zealand
| | - Jin Akagi
- The BioMEMS Research Group, School of Chemical Sciences, University of Auckland, Auckland, New Zealand
| | - Yoo Fujimura
- R&D Division, On-chip Biotechnologies, Tokyo, Japan
| | - Kazuo Takeda
- R&D Division, On-chip Biotechnologies, Tokyo, Japan
| |
Collapse
|
16
|
Microflow cytometers with integrated hydrodynamic focusing. SENSORS 2013; 13:4674-93. [PMID: 23571670 PMCID: PMC3673106 DOI: 10.3390/s130404674] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/01/2013] [Revised: 03/22/2013] [Accepted: 03/28/2013] [Indexed: 11/17/2022]
Abstract
This study demonstrates the suitability of microfluidic structures for high throughput blood cell analysis. The microfluidic chips exploit fully integrated hydrodynamic focusing based on two different concepts: Two-stage cascade focusing and spin focusing (vortex) principle. The sample--A suspension of micro particles or blood cells--is injected into a sheath fluid streaming at a substantially higher flow rate, which assures positioning of the particles in the center of the flow channel. Particle velocities of a few m/s are achieved as required for high throughput blood cell analysis. The stability of hydrodynamic particle positioning was evaluated by measuring the pulse heights distributions of fluorescence signals from calibration beads. Quantitative assessment based on coefficient of variation for the fluorescence intensity distributions resulted in a value of about 3% determined for the micro-device exploiting cascade hydrodynamic focusing. For the spin focusing approach similar values were achieved for sample flow rates being 1.5 times lower. Our results indicate that the performances of both variants of hydrodynamic focusing suit for blood cell differentiation and counting. The potential of the micro flow cytometer is demonstrated by detecting immunologically labeled CD3 positive and CD4 positive T-lymphocytes in blood.
Collapse
|
17
|
Akagi J, Kordon M, Zhao H, Matuszek A, Dobrucki J, Errington R, Smith PJ, Takeda K, Darzynkiewicz Z, Wlodkowic D. Real-time cell viability assays using a new anthracycline derivative DRAQ7®. Cytometry A 2012; 83:227-34. [PMID: 23165976 DOI: 10.1002/cyto.a.22228] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2012] [Revised: 09/25/2012] [Accepted: 10/15/2012] [Indexed: 01/11/2023]
Abstract
The exclusion of charged fluorescent dyes by intact cells has become a well-established assay for determining viability of cells. In search for a noninvasive fluorescent probe capable of long-term monitoring of cell death in real-time, we evaluated a new anthracycline derivative DRAQ7. The novel probe does not penetrate the plasma membrane of living cells but when the membrane integrity is compromised, it enters and binds readily to nuclear DNA to report cell death. It proved to be nontoxic to a panel of cancer cell lines grown continuously for up to 72 h and did not induce any detectable DNA damage signaling when analyzed using laser scanning microscopy and flow cytometry. The DRAQ7 provided a sensitive, real-time readout of cell death induced by a variety of stressors such as hypoxia, starvation, and drug-induced cytotoxicity. The overall responses to anticancer agents and resulting pharmacological dose-response profiles were not affected by the growth of tumor cells in the presence DRAQ7. Moreover, we for the first time introduced a near real-time microflow cytometric assay based on combination of DRAQ7 and mitochondrial inner membrane potential (ΔΨ(m) ) sensitive probe TMRM. We provide evidence that this low-dosage, real-time labeling procedure provides multiparameter and kinetic fingerprint of anticancer drug action.
Collapse
Affiliation(s)
- Jin Akagi
- The BioMEMS Research Group, School of Chemical Sciences, University of Auckland, Auckland, New Zealand
| | | | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Darzynkiewicz Z, Zhao H, Halicka HD, Rybak P, Dobrucki J, Wlodkowic D. DNA damage signaling assessed in individual cells in relation to the cell cycle phase and induction of apoptosis. Crit Rev Clin Lab Sci 2012; 49:199-217. [PMID: 23137030 DOI: 10.3109/10408363.2012.738808] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Reviewed are the phosphorylation events reporting activation of protein kinases and the key substrates critical for the DNA damage signaling (DDS). These DDS events are detected immunocytochemically using phospho-specific Abs; flow cytometry or image-assisted cytometry provide the means to quantitatively assess them on a cell by cell basis. The multiparameter analysis of the data is used to correlate these events with each other and relate to the cell cycle phase, DNA replication and induction of apoptosis. Expression of γH2AX as a possible marker of induction of DNA double strand breaks is the most widely studied event of DDS. Reviewed are applications of this multiparameter approach to investigate constitutive DDS reporting DNA damage by endogenous oxidants byproducts of oxidative phosphorylation. Also reviewed are its applications to detect and explore mechanisms of DDS induced by variety of exogenous agents targeting DNA such as exogenous oxidants, ionizing radiation, radiomimetic drugs, UV light, DNA topoisomerase I and II inhibitors, DNA crosslinking drugs and variety of environmental genotoxins. Analysis of DDS induced by these agents provides often a wealth of information about mechanism of induction and the type of DNA damage (lesion) and is reviewed in the context of cell cycle phase specificity, DNA replication, and induction of apoptosis or cell senescence. Critically assessed is interpretation of the data as to whether the observed DDS events report induction of a particular type of DNA lesion.
Collapse
Affiliation(s)
- Zbigniew Darzynkiewicz
- Brander Cancer Research Institute and Department of Pathology, New York Medical College, Valhalla, NY 10595, USA.
| | | | | | | | | | | |
Collapse
|
19
|
Simultaneous analysis of seven oligopeptides in microbial fuel cell by micro-fluidic chip with reflux injection mode. Talanta 2012; 100:338-43. [DOI: 10.1016/j.talanta.2012.07.079] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2012] [Revised: 07/26/2012] [Accepted: 07/30/2012] [Indexed: 01/25/2023]
|
20
|
Real-time concurrent monitoring of apoptosis, cytosolic calcium, and mitochondria permeability transition for hypermulticolor high-content screening of drug-induced mitochondrial dysfunction-mediated hepatotoxicity. Toxicol Lett 2012; 214:175-81. [DOI: 10.1016/j.toxlet.2012.08.027] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2012] [Revised: 08/28/2012] [Accepted: 08/29/2012] [Indexed: 11/22/2022]
|
21
|
Dong M, Martinez MM, Mayer MF, Pappas D. Single molecule fluorescence correlation spectroscopy of single apoptotic cells using a red-fluorescent caspase probe. Analyst 2012; 137:2997-3003. [PMID: 22314869 DOI: 10.1039/c2an16173g] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
The detection of single molecules in single cells has enabled biochemical analyses to be conducted with high sensitivity and high temporal resolution. In this work, detection of apoptosis was studied by single molecule fluorescence correlation spectroscopy (FCS) in single living cells. Caspase activity was assayed using a new red fluorogenic probe that avoids the spectral overlap of green fluorescent probes and cell autofluorescence. This new probe, 2SBPO-Casp, was synthesized by coupling a water-soluble Nile Blue derivative (2SBPO) to an aspartic acid residue. Upon apoptosis induction and caspase activation, free 2SBPO dye is shown to accumulate inside the cell after probe cleavage. In previous work in our lab, single molecule fluorescence in single apoptotic cells was detected 45 min after induction using a rhodamine 110-based probe. However, significant statistical analysis was needed to exclude false positives. The use of 2SBPO-Casp overcomes the autofluorescence problem and offers a steady fluorescence signal. In our single molecule FCS measurements, Ramos cells were determined apoptotic on the basis of their correlation coefficient value (R(2)). Cells that contain an R(2) ≥ 0.65 were identified as highly correlated and therefore determined to be apoptotic. Single apoptotic cells identified in this manner were found as early as 30 min after induction and the number of apoptotic cells reached a peak value at the 3rd hour, which is consistent with other techniques. Using single molecule techniques and a new apoptosis probe, the temporal dynamics were elucidated with better sensitivity and resolution than in previous studies.
Collapse
Affiliation(s)
- Meicong Dong
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX 79409, USA
| | | | | | | |
Collapse
|
22
|
Bogojevic D, Chamberlain MD, Barbulovic-Nad I, Wheeler AR. A digital microfluidic method for multiplexed cell-based apoptosis assays. LAB ON A CHIP 2012; 12:627-34. [PMID: 22159547 DOI: 10.1039/c2lc20893h] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Digital microfluidics (DMF), a fluid-handling technique in which picolitre-microlitre droplets are manipulated electrostatically on an array of electrodes, has recently become popular for applications in chemistry and biology. DMF devices are reconfigurable, have no moving parts, and are compatible with conventional high-throughput screening infrastructure (e.g., multiwell plate readers). For these and other reasons, digital microfluidics has been touted as being a potentially useful new tool for applications in multiplexed screening. Here, we introduce the first digital microfluidic platform used to implement parallel-scale cell-based assays. A fluorogenic apoptosis assay for caspase-3 activity was chosen as a model system because of the popularity of apoptosis as a target for anti-cancer drug discovery research. Dose-response profiles of caspase-3 activity as a function of staurosporine concentration were generated using both the digital microfluidic method and conventional techniques (i.e., pipetting, aspiration, and 96-well plates.) As expected, the digital microfluidic method had a 33-fold reduction in reagent consumption relative to the conventional technique. Although both types of methods used the same detector (a benchtop multiwell plate reader), the data generated by the digital microfluidic method had lower detection limits and greater dynamic range because apoptotic cells were much less likely to de-laminate when exposed to droplet manipulation by DMF relative to pipetting/aspiration in multiwell plates. We propose that the techniques described here represent an important milestone in the development of digital microfluidics as a useful tool for parallel cell-based screening and other applications.
Collapse
Affiliation(s)
- Dario Bogojevic
- Institute for Biomaterials and Biomedical Engineering, University of Toronto, 164 College St., Toronto, ON M5S 3G9, Canada
| | | | | | | |
Collapse
|
23
|
Gielen F, deMello AJ, Edel JB. Dielectric cell response in highly conductive buffers. Anal Chem 2012; 84:1849-53. [PMID: 22148418 DOI: 10.1021/ac2022103] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
We present a novel method for the identification of live and dead T-cells, dynamically flowing within highly conductive buffers. This technique discriminates between live and dead (heat treated) cells on the basis of dielectric properties variations. The key advantage of this technique lies in its operational simplicity, since cells do not have to be resuspended in isotonic low conductivity media. Herein, we demonstrate that at 40 MHz, we are able to statistically distinguish between live and dead cell populations.
Collapse
Affiliation(s)
- Fabrice Gielen
- Department of Chemistry, Imperial College London, South Kensington, London, SW7 2AZ, United Kingdom
| | | | | |
Collapse
|
24
|
Kettlitz SW, Valouch S, Sittel W, Lemmer U. Flexible planar microfluidic chip employing a light emitting diode and a PIN-photodiode for portable flow cytometers. LAB ON A CHIP 2012; 12:197-203. [PMID: 22086498 DOI: 10.1039/c1lc20672a] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Detection of fluorescence particles is a key method of flow cytometry. We evaluate the performance of a design for a microfluidic fluorescence particle detection device. Due to the planar design with low layer thicknesses, we avoid optical components such as lenses or dichroic mirrors and substitute them with a shadow mask and colored film filters. A commercially available LED is used as the light source and a PIN-photodiode as detector. This design approach reduces component cost and power consumption and enables supplying the device with power from a standard USB port. From evaluation of this design, we obtain a maximum particle detection frequency of up to 600 particles per second at a sensitivity of better than 4.7 × 10(5) MESF (molecules of equivalent soluble fluorochrome) measured with particles for FITC sensitivity calibration. Lowering the flow rate increases the instrument sensitivity by an order of magnitude enabling the detection of particles with 4.5 × 10(4) MESF.
Collapse
Affiliation(s)
- Siegfried W Kettlitz
- Light Technology Institute, Karlsruhe Institute of Technology, Kaiserstr. 12 Geb. 30.34, Karlsruhe, Baden-Württemberg 76131, Germany.
| | | | | | | |
Collapse
|