1
|
A Fast and Label-Free Potentiometric Method for Direct Detection of Glutamine with Silicon Nanowire Biosensors. BIOSENSORS 2022; 12:bios12060368. [PMID: 35735517 PMCID: PMC9221423 DOI: 10.3390/bios12060368] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Revised: 05/24/2022] [Accepted: 05/24/2022] [Indexed: 11/17/2022]
Abstract
In this paper, a potentiometric method is used for monitoring the concentration of glutamine in the bioprocess by employing silicon nanowire biosensors. Just one hydrolyzation reaction was used, which is much more convenient compared with the two-stage reactions in the published papers. For the silicon nanowire biosensor, the Al2O3 sensing layer provides a highly sensitive to solution-pH, which has near-Nernstian sensitivity. The sensitive region to detect glutamine is from ≤40 μM to 20 mM. The Sigmoidal function was used to model the pH-signal variation versus the glutamine concentration. Compared with the amperometric methods, a consistent result from different devices could be directly obtained. It is a fast and direct method achieved with our real-time setup. Also, it is a label-free method because just the pH variation of the solution is monitored. The obtained results show the feasibility of the potentiometric method for monitoring the glutamine concentrations in fermentation processes. Our approach in this paper can be applied to various analytes.
Collapse
|
2
|
Li YX, Yang M, Li PH, Chen SH, Li YY, Guo Z, Li SS, Jiang M, Lin CH, Huang XJ. Changing the Blood Test: Accurate Determination of Mercury(II) in One Microliter of Blood Using Oriented ZnO Nanobelt Array Film Solution-Gated Transistor Chips. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2019; 15:e1902433. [PMID: 31304682 DOI: 10.1002/smll.201902433] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2019] [Revised: 06/28/2019] [Indexed: 06/10/2023]
Abstract
The measurement of ultralow concentrations of heavy metal ions (HMIs) in blood is challenging. A new strategy for the determination of mercury ions (Hg2+ ) based on an oriented ZnO nanobelt (ZnO-NB) film solution-gated field-effect transistor (FET) chip is adopted. The FET chips are fabricated with ZnO-NB film channels with different orientations utilizing the Langmuir-Blodgett (L-B) assembly technique. The combined simulation and I-V behavior results show that the nanodevice with ZnO-NBs parallel to the channel has exceptional performance. The sensing capability of the oriented ZnO-NB film FET chips corresponds to an ultralow minimum detectable level (MDL) of 100 × 10-12 m in deionized water due to the change in the electrical double layer (EDL) arising from the synergism of the field-induced effect and the specific binding of Hg2+ to the thiol groups (-SH) on the film surface. Moreover, the prepared FET chips present excellent selectivity toward Hg2+ , excellent repeatability, and a rapid response time (less than 1 s) for various Hg2+ concentrations. The sensing performance corresponds to a low MDL of 10 × 10-9 m in real samples of a drop of blood.
Collapse
Affiliation(s)
- Yi-Xiang Li
- Key Laboratory of Environmental Optics and Technology, and Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei, 230031, P. R. China
- Department of Chemistry, University of Science and Technology of China, Hefei, 230026, P. R. China
| | - Meng Yang
- Key Laboratory of Environmental Optics and Technology, and Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei, 230031, P. R. China
| | - Pei-Hua Li
- Key Laboratory of Environmental Optics and Technology, and Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei, 230031, P. R. China
- Department of Chemistry, University of Science and Technology of China, Hefei, 230026, P. R. China
| | - Shi-Hua Chen
- Key Laboratory of Environmental Optics and Technology, and Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei, 230031, P. R. China
- Department of Chemistry, University of Science and Technology of China, Hefei, 230026, P. R. China
| | - Yong-Yu Li
- Key Laboratory of Environmental Optics and Technology, and Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei, 230031, P. R. China
- Institutes of Physical Science and Information Technology, Anhui University, Hefei, 230601, P. R. China
| | - Zheng Guo
- Institutes of Physical Science and Information Technology, Anhui University, Hefei, 230601, P. R. China
| | - Shan-Shan Li
- Key Laboratory of Environmental Optics and Technology, and Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei, 230031, P. R. China
- Department of Chemistry, University of Science and Technology of China, Hefei, 230026, P. R. China
| | - Min Jiang
- Key Laboratory of Environmental Optics and Technology, and Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei, 230031, P. R. China
- Department of Chemistry, University of Science and Technology of China, Hefei, 230026, P. R. China
| | - Chu-Hong Lin
- Key Laboratory of Environmental Optics and Technology, and Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei, 230031, P. R. China
- Department of Chemistry, University of Science and Technology of China, Hefei, 230026, P. R. China
| | - Xing-Jiu Huang
- Key Laboratory of Environmental Optics and Technology, and Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei, 230031, P. R. China
- Department of Chemistry, University of Science and Technology of China, Hefei, 230026, P. R. China
- Institutes of Physical Science and Information Technology, Anhui University, Hefei, 230601, P. R. China
| |
Collapse
|
3
|
Lowe BM, Sun K, Zeimpekis I, Skylaris CK, Green NG. Field-effect sensors - from pH sensing to biosensing: sensitivity enhancement using streptavidin-biotin as a model system. Analyst 2018; 142:4173-4200. [PMID: 29072718 DOI: 10.1039/c7an00455a] [Citation(s) in RCA: 78] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Field-Effect Transistor sensors (FET-sensors) have been receiving increasing attention for biomolecular sensing over the last two decades due to their potential for ultra-high sensitivity sensing, label-free operation, cost reduction and miniaturisation. Whilst the commercial application of FET-sensors in pH sensing has been realised, their commercial application in biomolecular sensing (termed BioFETs) is hindered by poor understanding of how to optimise device design for highly reproducible operation and high sensitivity. In part, these problems stem from the highly interdisciplinary nature of the problems encountered in this field, in which knowledge of biomolecular-binding kinetics, surface chemistry, electrical double layer physics and electrical engineering is required. In this work, a quantitative analysis and critical review has been performed comparing literature FET-sensor data for pH-sensing with data for sensing of biomolecular streptavidin binding to surface-bound biotin systems. The aim is to provide the first systematic, quantitative comparison of BioFET results for a single biomolecular analyte, specifically streptavidin, which is the most commonly used model protein in biosensing experiments, and often used as an initial proof-of-concept for new biosensor designs. This novel quantitative and comparative analysis of the surface potential behaviour of a range of devices demonstrated a strong contrast between the trends observed in pH-sensing and those in biomolecule-sensing. Potential explanations are discussed in detail and surface-chemistry optimisation is shown to be a vital component in sensitivity-enhancement. Factors which can influence the response, yet which have not always been fully appreciated, are explored and practical suggestions are provided on how to improve experimental design.
Collapse
Affiliation(s)
- Benjamin M Lowe
- Department of Electronics and Computer Science, Nano Research Group, University of Southampton, UK.
| | - Kai Sun
- Department of Electronics and Computer Science, Nano Research Group, University of Southampton, UK.
| | - Ioannis Zeimpekis
- Department of Electronics and Computer Science, Nano Research Group, University of Southampton, UK.
| | | | - Nicolas G Green
- Department of Electronics and Computer Science, Nano Research Group, University of Southampton, UK.
| |
Collapse
|
4
|
Lee J, Wipf M, Mu L, Adams C, Hannant J, Reed MA. Metal-coated microfluidic channels: An approach to eliminate streaming potential effects in nano biosensors. Biosens Bioelectron 2017; 87:447-452. [DOI: 10.1016/j.bios.2016.08.065] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2016] [Revised: 08/15/2016] [Accepted: 08/19/2016] [Indexed: 10/21/2022]
|
5
|
Duan X, Rajan NK, Izadi MH, Reed MA. Complementary metal oxide semiconductor-compatible silicon nanowire biofield-effect transistors as affinity biosensors. Nanomedicine (Lond) 2014; 8:1839-51. [PMID: 24156488 DOI: 10.2217/nnm.13.156] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
Affinity biosensors use biorecognition elements and transducers to convert a biochemical event into a recordable signal. They provides the molecule binding information, which includes the dynamics of biomolecular association and dissociation, and the equilibrium association constant. Complementary metal oxide semiconductor-compatible silicon (Si) nanowires configured as a field-effect transistor (NW FET) have shown significant advantages for real-time, label-free and highly sensitive detection of a wide range of biomolecules. Most research has focused on reducing the detection limit of Si-NW FETs but has provided less information about the real binding parameters of the biomolecular interactions. Recently, Si-NW FETs have been demonstrated as affinity biosensors to quantify biomolecular binding affinities and kinetics. They open new applications for NW FETs in the nanomedicine field and will bring such sensor technology a step closer to commercial point-of-care applications. This article summarizes the recent advances in bioaffinity measurement using Si-NW FETs, with an emphasis on the different approaches used to address the issues of sensor calibration, regeneration, binding kinetic measurements, limit of detection, sensor surface modification, biomolecule charge screening, reference electrode integration and nonspecific molecular binding.
Collapse
Affiliation(s)
- Xuexin Duan
- State Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University, Tianjin 300072, China
| | | | | | | |
Collapse
|
6
|
Influence of conductivity and dielectric constant of water-dioxane mixtures on the electrical response of SiNW-based FETs. SENSORS 2014; 14:2350-61. [PMID: 24481233 PMCID: PMC3958210 DOI: 10.3390/s140202350] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/26/2013] [Revised: 01/22/2014] [Accepted: 01/24/2014] [Indexed: 02/07/2023]
Abstract
In this study, we report on the electrical response of top-down, p-type silicon nanowire field-effect transistors exposed to water and mixtures of water and dioxane. First, the capacitive coupling of the back gate and the liquid gate via an Ag/AgCl electrode were compared in water. It was found that for liquid gating smaller potentials are needed to obtain similar responses of the nanowire compared to back gating. In the case of back gating, the applied potential couples through the buried oxide layer, indicating that the associated capacitance dominates all other capacitances involved during this mode of operation. Next, the devices were exposed to mixtures of water and dioxane to study the effect of these mixtures on the device characteristics, including the threshold voltage (VT). The VT dependency on the mixture composition was found to be related to the decreased dissociation of the surface silanol groups and the conductivity of the mixture used. This latter was confirmed by experiments with constant conductivity and varying water–dioxane mixtures.
Collapse
|
7
|
Guan W, Rajan NK, Duan X, Reed MA. Quantitative probing of surface charges at dielectric-electrolyte interfaces. LAB ON A CHIP 2013; 13:1431-1436. [PMID: 23411945 DOI: 10.1039/c3lc41351a] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
The intrinsic charging status at the dielectric-electrolyte interface (DEI) plays a critical role for electrofluidic gating in microfluidics and nanofluidics, which offers opportunities for integration of wet ionics with dry electronics. A convenient approach to quantitatively probe the surface charges at the DEI for material pre-selection purpose has been lacking so far. We report here a low-cost, off-chip extended gate field effect transistor configuration for direct electrostatic probing the charging status at the DEI. Capacitive coupling between the surface charges and the floating extended gate is utilized for signal transducing. The relationship between the surface charge density and the experimentally accessible quantities is given by device modeling. The multiplexing ability makes measuring a local instead of a globally averaged surface charge possible.
Collapse
Affiliation(s)
- Weihua Guan
- Department of Electrical Engineering, Yale University, New Haven, Connecticut 06520, USA
| | | | | | | |
Collapse
|