• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4609573)   Today's Articles (16)   Subscriber (49378)
For: Guziński M, Lisak G, Sokalski T, Bobacka J, Ivaska A, Bocheńska M, Lewenstam A. Solid-Contact Ion-Selective Electrodes with Highly Selective Thioamide Derivatives of p-tert-Butylcalix[4]arene for the Determination of Lead(II) in Environmental Samples. Anal Chem 2013;85:1555-61. [DOI: 10.1021/ac302772v] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Number Cited by Other Article(s)
1
Yang M, Silva R, Zhao K, Ding R, Foo JLC, Ge L, Lisak G. Corrective protocol to predict interference free sensor response for paper-based solution sampling coupled with heavy metal sensitive ion-selective electrodes. Analyst 2024. [PMID: 39005217 DOI: 10.1039/d4an00841c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/16/2024]
2
Kulkarni BB, Suvina V, Balakrishna RG, Nagaraju DH, Jagadish K. 1D GNR‐PPy Composite for Remarkably Sensitive Detection of Heavy Metal Ions in Environmental Water**. ChemElectroChem 2022. [DOI: 10.1002/celc.202101269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
3
Lisak G. Reliable environmental trace heavy metal analysis with potentiometric ion sensors - reality or a distant dream. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2021;289:117882. [PMID: 34364114 DOI: 10.1016/j.envpol.2021.117882] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2021] [Revised: 07/13/2021] [Accepted: 07/29/2021] [Indexed: 06/13/2023]
4
Mao C, Yuan D, Wang L, Bakker E. Separating boundary potential changes at thin solid contact ion transfer voltammetric membrane electrodes. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2020.114800] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
5
Yu J, Han J, Li P, Huang Z, Chen S. Simultaneous Determination of Cd 2+ , Cu 2+ , Pb 2+ and Hg 2+ Based on 1,4‐Benzenedithiol‐2,5‐diamino‐hydrochloride‐1,3,5‐triformylbenzene Covalent‐Organic Frameworks. ChemistrySelect 2020. [DOI: 10.1002/slct.202003417] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
6
Kushwaha CS, Shukla SK. Potentiometric extractive sensing of lead ions over a nickel oxide intercalated chitosan-grafted-polyaniline composite. Dalton Trans 2020;49:13862-13871. [PMID: 33006591 DOI: 10.1039/d0dt02687e] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
7
Kamel AH, Amr AEGE, Al-Omar MA, Almehizia AA. Solid-State Membrane Sensors Based on Man-Tailored Biomimetic Receptors for Selective Recognition of Isoproturon and Diuron Herbicides. MEMBRANES 2020;10:membranes10100279. [PMID: 33053713 PMCID: PMC7599700 DOI: 10.3390/membranes10100279] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Revised: 09/30/2020] [Accepted: 10/06/2020] [Indexed: 11/16/2022]
8
Yi K, Zhang L. Embedding dual fluoroprobe in metal-organic frameworks for continuous visual recognition of Pb2+ and PO43- via fluorescence 'turn-off-on' response: Agar test paper and fingerprint. JOURNAL OF HAZARDOUS MATERIALS 2020;389:122141. [PMID: 32000121 DOI: 10.1016/j.jhazmat.2020.122141] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/05/2019] [Revised: 01/16/2020] [Accepted: 01/18/2020] [Indexed: 06/10/2023]
9
Shao Y, Ying Y, Ping J. Recent advances in solid-contact ion-selective electrodes: functional materials, transduction mechanisms, and development trends. Chem Soc Rev 2020;49:4405-4465. [DOI: 10.1039/c9cs00587k] [Citation(s) in RCA: 143] [Impact Index Per Article: 35.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
10
Joon NK, He N, Ruzgas T, Bobacka J, Lisak G. PVC-Based Ion-Selective Electrodes with a Silicone Rubber Outer Coating with Improved Analytical Performance. Anal Chem 2019;91:10524-10531. [DOI: 10.1021/acs.analchem.9b01490] [Citation(s) in RCA: 46] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
11
Disposable Multi-Walled Carbon Nanotubes-Based Plasticizer-Free Solid-Contact Pb2+-Selective Electrodes with a Sub-PPB Detection Limit †. SENSORS 2019;19:s19112550. [PMID: 31167473 PMCID: PMC6603586 DOI: 10.3390/s19112550] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/13/2019] [Revised: 05/31/2019] [Accepted: 06/02/2019] [Indexed: 11/20/2022]
12
Łukasik N, Wagner-Wysiecka E, Małachowska A. Iron(iii)-selective materials based on a catechol-bearing amide for optical sensing. Analyst 2019;144:3119-3127. [PMID: 30924820 DOI: 10.1039/c9an00188c] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
13
Zhang L, Gupta B, Goudeau B, Mano N, Kuhn A. Wireless Electromechanical Readout of Chemical Information. J Am Chem Soc 2018;140:15501-15506. [PMID: 30347149 DOI: 10.1021/jacs.8b10072] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
14
Ion-Selective Electrodes for Detection of Lead (II) in Drinking Water: A Mini-Review. ENVIRONMENTS 2018. [DOI: 10.3390/environments5090095] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
15
Zahran EM, Fatila EM, Chen CH, Flood AH, Bachas LG. Cyanostar: C–H Hydrogen Bonding Neutral Carrier Scaffold for Anion-Selective Sensors. Anal Chem 2018;90:1925-1933. [DOI: 10.1021/acs.analchem.7b04008] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
16
Jarvis JM, Guzinski M, Perez F, Pendley BD, Lindner E. Differences in Electrochemically Deposited PEDOT(PSS) Films on Au and Pt Substrate Electrodes: A Quartz Crystal Microbalance Study. ELECTROANAL 2017. [DOI: 10.1002/elan.201700699] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
17
Ramanjaneyulu PS, Kundu K, Sharma MK, Nayak SK. Development of New Cs+ Ion-Selective Electrode with Alkyl-Bridged Calix[4]arene Crown-6 Compounds for the Determination of Cs+ in Nuclear Waste Streams. ChemistrySelect 2017. [DOI: 10.1002/slct.201701018] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
18
Ruecha N, Chailapakul O, Suzuki K, Citterio D. Fully Inkjet-Printed Paper-Based Potentiometric Ion-Sensing Devices. Anal Chem 2017;89:10608-10616. [DOI: 10.1021/acs.analchem.7b03177] [Citation(s) in RCA: 84] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
19
Ramanjaneyulu PS, Kumar AN, Sharma MK. Development of a new all solid contact Cs+ ion selective electrode. J Radioanal Nucl Chem 2017. [DOI: 10.1007/s10967-017-5318-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
20
Crespo GA. Recent Advances in Ion-selective membrane electrodes for in situ environmental water analysis. Electrochim Acta 2017. [DOI: 10.1016/j.electacta.2017.05.159] [Citation(s) in RCA: 78] [Impact Index Per Article: 11.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
21
Jeszke M, Trzciński K, Karczewski J, Luboch E. Investigation of poly(3,4-ethylenedioxythiophene) deposition method influence on properties of ion-selective electrodes based on bis(benzo-15-crown-5) derivatives. Electrochim Acta 2017. [DOI: 10.1016/j.electacta.2017.05.197] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
22
Guzinski M, Jarvis JM, D’Orazio P, Izadyar A, Pendley BD, Lindner E. Solid-Contact pH Sensor without CO2 Interference with a Superhydrophobic PEDOT-C14 as Solid Contact: The Ultimate “Water Layer” Test. Anal Chem 2017;89:8468-8475. [DOI: 10.1021/acs.analchem.7b02009] [Citation(s) in RCA: 59] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
23
Guzinski M, Jarvis JM, Perez F, Pendley BD, Lindner E, De Marco R, Crespo GA, Acres RG, Walker R, Bishop J. PEDOT(PSS) as Solid Contact for Ion-Selective Electrodes: The Influence of the PEDOT(PSS) Film Thickness on the Equilibration Times. Anal Chem 2017;89:3508-3516. [DOI: 10.1021/acs.analchem.6b04625] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
24
Chen J, Zhu Y, Zhang Y. Glutathione-capped Mn-doped ZnS quantum dots as a room-temperature phosphorescence sensor for the detection of Pb(2+) ions. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2016;164:98-102. [PMID: 27085295 DOI: 10.1016/j.saa.2016.04.014] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2015] [Revised: 04/04/2016] [Accepted: 04/05/2016] [Indexed: 06/05/2023]
25
Lisak G, Arnebrant T, Lewenstam A, Bobacka J, Ruzgas T. In Situ Potentiometry and Ellipsometry: A Promising Tool to Study Biofouling of Potentiometric Sensors. Anal Chem 2016;88:3009-14. [DOI: 10.1021/acs.analchem.5b04364] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
26
Hu J, Stein A, Bühlmann P. Rational design of all-solid-state ion-selective electrodes and reference electrodes. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2015.11.004] [Citation(s) in RCA: 220] [Impact Index Per Article: 27.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
27
Jamali A, Tehrani AA, Shemirani F, Morsali A. Lanthanide metal–organic frameworks as selective microporous materials for adsorption of heavy metal ions. Dalton Trans 2016;45:9193-200. [DOI: 10.1039/c6dt00782a] [Citation(s) in RCA: 97] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
28
Bakker E. Electroanalysis with Membrane Electrodes and Liquid–Liquid Interfaces. Anal Chem 2015;88:395-413. [DOI: 10.1021/acs.analchem.5b04034] [Citation(s) in RCA: 82] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
29
Huang MR, Ding YB, Li XG, Liu Y, Xi K, Gao CL, Kumar RV. Synthesis of semiconducting polymer microparticles as solid ionophore with abundant complexing sites for long-life Pb(II) sensors. ACS APPLIED MATERIALS & INTERFACES 2014;6:22096-22107. [PMID: 25403150 DOI: 10.1021/am505463f] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
30
Multicalibrational procedure for more reliable analyses of ions at low analyte concentrations. Electrochim Acta 2014. [DOI: 10.1016/j.electacta.2014.02.091] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
31
Huang MR, Ding YB, Li XG. Combinatorial screening of potentiometric Pb(II) sensors from polysulfoaminoanthraquinone solid ionophore. ACS COMBINATORIAL SCIENCE 2014;16:128-38. [PMID: 24512280 DOI: 10.1021/co400140g] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
32
Guziński M, Lisak G, Kupis J, Jasiński A, Bocheńska M. Lead(II)-selective ionophores for ion-selective electrodes: A review. Anal Chim Acta 2013;791:1-12. [DOI: 10.1016/j.aca.2013.04.044] [Citation(s) in RCA: 59] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2013] [Revised: 04/19/2013] [Accepted: 04/22/2013] [Indexed: 11/30/2022]
33
Fu L, Zhuang J, Lai W, Que X, Lu M, Tang D. Portable and quantitative monitoring of heavy metal ions using DNAzyme-capped mesoporous silica nanoparticles with a glucometer readout. J Mater Chem B 2013;1:6123-6128. [DOI: 10.1039/c3tb21155j] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA