1
|
Shriver Z, Sasisekharan R. Capillary Electrophoretic Analysis of Isolated Sulfated Polysaccharides to Characterize Pharmaceutical Products. Methods Mol Biol 2021; 2303:329-339. [PMID: 34626391 DOI: 10.1007/978-1-0716-1398-6_27] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/16/2023]
Abstract
Capillary electrophoresis is a powerful methodology for quantification and structural characterization of highly anionic polysaccharides. Separation of saccharides under conditions of electrophoretic flow, typically achieved under low pH (Ampofo et al., Anal Biochem 199: 249-255, 1991; Rhomberg et al., Proc Natl Acad Sci U S A 95: 4176-4181, 1998) is charge-based. Resolution of components is often superior to flow-based techniques, such as liquid chromatography. During the heparin contamination crisis, capillary electrophoresis was one of the key methodologies used to identify whether or not heparin lots were contaminated (Guerrini et al., Nat Biotechnol 26: 669-675, 2008; Ye et al., J Pharm Biomed Anal 85: 99-107, 2013; Volpi et al., Electrophoresis 33: 1531-1537, 2012).Here we describe a method for the isolation of sulfated heparin/heparan sulfate saccharides from urine, their digestion by deployment of heparinase enzymes (Ernst et al., Crit Rev Biochem Mol Biol 30: 387-444, 1995) resolution of species through use of orthogonal digestions, and analysis of the resulting disaccharides by capillary electrophoresis.
Collapse
Affiliation(s)
- Zachary Shriver
- Department of Biological Engineering, Koch Institute of Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Ram Sasisekharan
- Department of Biological Engineering, Koch Institute of Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, USA.
| |
Collapse
|
2
|
Lee S, Chintalapudi K, Badu-Tawiah AK. Clinical Chemistry for Developing Countries: Mass Spectrometry. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2021; 14:437-465. [PMID: 33979544 PMCID: PMC8932337 DOI: 10.1146/annurev-anchem-091520-085936] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Early disease diagnosis is necessary to enable timely interventions. Implementation of this vital task in the developing world is challenging owing to limited resources. Diagnostic approaches developed for resource-limited settings have often involved colorimetric tests (based on immunoassays) due to their low cost. Unfortunately, the performance/sensitivity of such simplistic tests are often limited and significantly hinder opportunities for early disease detection. A new criterion for selecting diagnostic tests in low- and middle-income countries is proposed here that is based on performance-to-cost ratio. For example, modern mass spectrometry (MS) now involves analysis of the native sample in the open laboratory environment, enabling applications in many fields, including clinical research, forensic science, environmental analysis, and agriculture. In this critical review, we summarize recent developments in chemistry that enable MS to be applied effectively in developing countries. In particular, we argue that closed automated analytical systems may not offer the analytical flexibility needed in resource-limited settings. Alternative strategies proposed here have potential to be widely accepted in low- and middle-income countries through the utilization of the open-source ambient MS platform that enables microsampling techniques such as dried blood spot to be coupled with miniature mass spectrometers in a centralized analytical platform. Consequently, costs associated with sample handling and maintenance can be reduced by >50% of the total ownership cost, permitting analytical measurements to be operated at high performance-to-cost ratios in the developing world.
Collapse
Affiliation(s)
- Suji Lee
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210, USA;
| | - Kavyasree Chintalapudi
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210, USA;
| | - Abraham K Badu-Tawiah
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210, USA;
| |
Collapse
|
3
|
Glycosaminoglycans in biological samples – Towards identification of novel biomarkers. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2019.115732] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
4
|
Devlin A, Mycroft-West C, Procter P, Cooper L, Guimond S, Lima M, Yates E, Skidmore M. Tools for the Quality Control of Pharmaceutical Heparin. MEDICINA (KAUNAS, LITHUANIA) 2019; 55:E636. [PMID: 31557911 PMCID: PMC6843833 DOI: 10.3390/medicina55100636] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2019] [Revised: 09/02/2019] [Accepted: 09/04/2019] [Indexed: 11/25/2022]
Abstract
Heparin is a vital pharmaceutical anticoagulant drug and remains one of the few naturally sourced pharmaceutical agents used clinically. Heparin possesses a structural order with up to four levels of complexity. These levels are subject to change based on the animal or even tissue sources that they are extracted from, while higher levels are believed to be entirely dynamic and a product of their surrounding environments, including bound proteins and associated cations. In 2008, heparin sources were subject to a major contamination with a deadly compound-an over-sulphated chondroitin sulphate polysaccharide-that resulted in excess of 100 deaths within North America alone. In consideration of this, an arsenal of methods to screen for heparin contamination have been applied, based primarily on the detection of over-sulphated chondroitin sulphate. The targeted nature of these screening methods, for this specific contaminant, may leave contamination by other entities poorly protected against, but novel approaches, including library-based chemometric analysis in concert with a variety of spectroscopic methods, could be of great importance in combating future, potential threats.
Collapse
Affiliation(s)
- Anthony Devlin
- Molecular & Structural Biosciences, School of Life Sciences, Keele University, Huxley Building, Keele, Staffordshire ST5 5BG, UK.
| | - Courtney Mycroft-West
- Molecular & Structural Biosciences, School of Life Sciences, Keele University, Huxley Building, Keele, Staffordshire ST5 5BG, UK.
| | - Patricia Procter
- Molecular & Structural Biosciences, School of Life Sciences, Keele University, Huxley Building, Keele, Staffordshire ST5 5BG, UK.
| | - Lynsay Cooper
- Molecular & Structural Biosciences, School of Life Sciences, Keele University, Huxley Building, Keele, Staffordshire ST5 5BG, UK.
| | - Scott Guimond
- Institute for Science and Technology in Medicine, Keele University, Keele, Staffordshire ST5 5BG, UK.
- School of Biological Sciences, University of Liverpool, Crown Street, Liverpool L69 7ZB, UK.
| | - Marcelo Lima
- Molecular & Structural Biosciences, School of Life Sciences, Keele University, Huxley Building, Keele, Staffordshire ST5 5BG, UK.
| | - Edwin Yates
- Molecular & Structural Biosciences, School of Life Sciences, Keele University, Huxley Building, Keele, Staffordshire ST5 5BG, UK.
- School of Biological Sciences, University of Liverpool, Crown Street, Liverpool L69 7ZB, UK.
| | - Mark Skidmore
- Molecular & Structural Biosciences, School of Life Sciences, Keele University, Huxley Building, Keele, Staffordshire ST5 5BG, UK.
- Institute for Science and Technology in Medicine, Keele University, Keele, Staffordshire ST5 5BG, UK.
- School of Biological Sciences, University of Liverpool, Crown Street, Liverpool L69 7ZB, UK.
| |
Collapse
|
5
|
Im J, Lindsay S, Wang X, Zhang P. Single Molecule Identification and Quantification of Glycosaminoglycans Using Solid-State Nanopores. ACS NANO 2019; 13:6308-6318. [PMID: 31121093 DOI: 10.1021/acsnano.9b00618] [Citation(s) in RCA: 51] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Glycosaminoglycans (GAGs) are a class of polysaccharides with potent biological activities. Due to their complex and heterogeneous composition, varied charge, polydispersity, and presence of isobaric stereoisomers, the analysis of GAG samples poses considerable challenges to current analytical techniques. In the present study, we combined solid-state nanopores-a single molecule sensor with a support vector machine (SVM)-a machine learning algorithm for the analysis of GAGs. Our results indicate that the nanopore/SVM technique could distinguish between monodisperse fragments of heparin and chondroitin sulfate with high accuracy (>90%), allowing as low as 0.8% (w/w) of chondroitin sulfate impurities in a heparin sample to be detected. In addition, the nanopore/SVM technique distinguished between unfractionated heparin (UFH) and enoxaparin (low molecular weight heparin) with an accuracy of ∼94% on average. With a reference sample for calibration, a nanopore could achieve nanomolar sensitivity and a 5-Log dynamic range. We were able to quantify heparin with reasonable accuracy using multiple nanopores. Our studies demonstrate the potential of the nanopore/SVM technique to quantify and identify GAGs.
Collapse
|
6
|
Jiang Q, Dai D, Li H, Chen DDY. Simultaneous determination of multiple components in cigarettes by mechanochemical extraction and direct analysis in real time mass spectrometry in minutes. Anal Chim Acta 2019; 1057:70-79. [PMID: 30832920 DOI: 10.1016/j.aca.2019.01.024] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2018] [Revised: 01/09/2019] [Accepted: 01/14/2019] [Indexed: 01/14/2023]
Abstract
A simple, rapid and high throughput analytical approach with combination of mechanochemical extraction (MCE) and direct analysis in real time mass spectrometry (DART-MS) analysis was developed for the simultaneous determination of multiple chemical components in cigarette fillers. Different kinds of substances including nicotine, cigarette alkaloids, carbohydrates, organic acids, humectants and other additives were successfully extracted using MCE and detected by high resolution DART-MS. Six solvents of various polarities were compared during MCE process and significant differences were observed. Different brands of cigarettes as well as standard research cigarette exhibited distinctive chemical features and DART-MS fingerprints. Principle component analysis showed clear differentiation among different cigarettes extracted with the same solvent and different solvent extracts of the same type of cigarette. The putative chemical formulas were proposed based on accurate m/z values with <10 ppm mass errors. The relative contents of nicotine and other identified substances were compared and significant differences were observed among cigarettes of different locations. The whole procedure of MCE combined with DART-MS only takes minutes from raw cigarette fillers to obtaining the semi-quantitative results. The operation is simple and high throughput, providing an efficient method to analyze cigarette composition, and to establish a methodology to acquire the rapid cigarette fingerprints for quality control.
Collapse
Affiliation(s)
- Qing Jiang
- Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, Jiangsu Key Laboratory of Biomedical Materials, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing, 210023, China
| | - Diya Dai
- Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, Jiangsu Key Laboratory of Biomedical Materials, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing, 210023, China
| | - Hongli Li
- Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, Jiangsu Key Laboratory of Biomedical Materials, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing, 210023, China.
| | - David D Y Chen
- Department of Chemistry, University of British Columbia, Vancouver, BC V6T 1Z1, Canada.
| |
Collapse
|
7
|
Wang Y, Guan A, Wickramasekara S, Phillips KS. Analytical Chemistry in the Regulatory Science of Medical Devices. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2018; 11:307-327. [PMID: 29579404 DOI: 10.1146/annurev-anchem-061417-125556] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
In the United States, regulatory science is the science of developing new tools, standards, and approaches to assess the safety, efficacy, quality, and performance of all Food and Drug Administration-regulated products. Good regulatory science facilitates consumer access to innovative medical devices that are safe and effective throughout the Total Product Life Cycle (TPLC). Because the need to measure things is fundamental to the regulatory science of medical devices, analytical chemistry plays an important role, contributing to medical device technology in two ways: It can be an integral part of an innovative medical device (e.g., diagnostic devices), and it can be used to support medical device development throughout the TPLC. In this review, we focus on analytical chemistry as a tool for the regulatory science of medical devices. We highlight recent progress in companion diagnostics, medical devices on chips for preclinical testing, mass spectrometry for postmarket monitoring, and detection/characterization of bacterial biofilm to prevent infections.
Collapse
Affiliation(s)
- Yi Wang
- Division of Biology, Chemistry, and Materials Science, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Office of Medical Products and Tobacco, US Food and Drug Administration, Silver Spring, Maryland 20993, USA;
| | - Allan Guan
- Division of Biology, Chemistry, and Materials Science, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Office of Medical Products and Tobacco, US Food and Drug Administration, Silver Spring, Maryland 20993, USA;
| | - Samanthi Wickramasekara
- Division of Biology, Chemistry, and Materials Science, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Office of Medical Products and Tobacco, US Food and Drug Administration, Silver Spring, Maryland 20993, USA;
| | - K Scott Phillips
- Division of Biology, Chemistry, and Materials Science, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Office of Medical Products and Tobacco, US Food and Drug Administration, Silver Spring, Maryland 20993, USA;
| |
Collapse
|
8
|
Ma H, Jiang Q, Dai D, Li H, Bi W, Da Yong Chen D. Direct Analysis in Real Time Mass Spectrometry for Characterization of Large Saccharides. Anal Chem 2018; 90:3628-3636. [DOI: 10.1021/acs.analchem.8b00242] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Affiliation(s)
- Huiying Ma
- Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, Jiangsu Key Laboratory of Biomedical Materials, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China
| | - Qing Jiang
- Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, Jiangsu Key Laboratory of Biomedical Materials, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China
| | - Diya Dai
- Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, Jiangsu Key Laboratory of Biomedical Materials, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China
| | - Hongli Li
- Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, Jiangsu Key Laboratory of Biomedical Materials, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China
| | - Wentao Bi
- Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, Jiangsu Key Laboratory of Biomedical Materials, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China
| | - David Da Yong Chen
- Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, Jiangsu Key Laboratory of Biomedical Materials, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China
- Department of Chemistry, University of British Columbia, Vancouver BC V6T 1Z1, Canada
| |
Collapse
|
9
|
Szajek AY, Chess E, Johansen K, Gratzl G, Gray E, Keire D, Linhardt RJ, Liu J, Morris T, Mulloy B, Nasr M, Shriver Z, Torralba P, Viskov C, Williams R, Woodcock J, Workman W, Al-Hakim A. The US regulatory and pharmacopeia response to the global heparin contamination crisis. Nat Biotechnol 2017; 34:625-30. [PMID: 27281424 DOI: 10.1038/nbt.3606] [Citation(s) in RCA: 84] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
The contamination of the widely used lifesaving anticoagulant drug heparin in 2007 has drawn renewed attention to the challenges that are associated with the characterization, quality control and standardization of complex biological medicines from natural sources. Heparin is a linear, highly sulfated polysaccharide consisting of alternating glucosamine and uronic acid monosaccharide residues. Heparin has been used successfully as an injectable antithrombotic medicine since the 1930s, and its isolation from animal sources (primarily porcine intestine) as well as its manufacturing processes have not changed substantially since its introduction. The 2007 heparin contamination crisis resulted in several deaths in the United States and hundreds of adverse reactions worldwide, revealing the vulnerability of a complex global supply chain to sophisticated adulteration. This Perspective discusses how the US Food and Drug Administration (FDA), the United States Pharmacopeial Convention (USP) and international stakeholders collaborated to redefine quality expectations for heparin, thus making an important natural product better controlled and less susceptible to economically motivated adulteration.
Collapse
Affiliation(s)
- Anita Y Szajek
- Biologics and Biotechnology Department, US Pharmacopeia, Rockville, Maryland, USA
| | - Edward Chess
- Structure Elucidation/Technology Resources, Baxter Healthcare Corporation, Round Lake, Illinois, USA
| | | | - Gyöngyi Gratzl
- Boehringer Ingelheim, Ben Venue Laboratories, Inc., Bedford, Ohio, USA
| | - Elaine Gray
- National Institute for Biological Standards and Control, South Mimms, Potters Bar, UK
| | - David Keire
- US Food and Drug Administration/Division of Pharmaceutical Analysis, St. Louis, Missouri, USA
| | - Robert J Linhardt
- Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, New York, USA
| | - Jian Liu
- Eshelman School of Pharmacy, University of North Carolina, Chapel Hill, North Carolina, USA
| | - Tina Morris
- Biologics and Biotechnology Department, US Pharmacopeia, Rockville, Maryland, USA
| | - Barbara Mulloy
- National Institute for Biological Standards and Control, South Mimms, Potters Bar, UK.,Institute of Pharmaceutical Science King's College London, Franklin Wilkins Building, Waterloo Campus, London, UK
| | - Moheb Nasr
- R&D, GlaxoSmithKline, Collegeville, Pennsylvania, USA
| | - Zachary Shriver
- Department of Biological Engineering, Harvard-MIT Division of Health Sciences &Technology, Koch institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Pearle Torralba
- Product Development - Analytical Innovation and Development, Fresenius Kabi USA, Skokie, Illinois, USA
| | | | | | - Janet Woodcock
- Center for Drug Evaluation and Research, US Food and Drug Administration, Silver Spring, Maryland, USA
| | - Wesley Workman
- Pfizer Quality Operations Biotech, Chesterfield, Missouri, USA
| | - Ali Al-Hakim
- Center for Drug Evaluation and Research, US Food and Drug Administration, Silver Spring, Maryland, USA
| |
Collapse
|
10
|
Li H, Hitchins VM, Wickramasekara S. Rapid detection of bacterial endotoxins in ophthalmic viscosurgical device materials by direct analysis in real time mass spectrometry. Anal Chim Acta 2016; 943:98-105. [PMID: 27769383 PMCID: PMC5500980 DOI: 10.1016/j.aca.2016.09.030] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2016] [Revised: 09/23/2016] [Accepted: 09/24/2016] [Indexed: 01/17/2023]
Abstract
Bacterial endotoxins are lipopolysaccharides bound to the bacterial cell wall and released when bacteria rupture or disintegrate. Possible contamination of endotoxin in ophthalmic devices can cause a painful eye inflammation or result in toxic anterior segment syndrome after cataract surgery. Measurement of bacterial endotoxin in medical device materials is difficult since endotoxin binds with polymer matrix and some of the materials are very viscous and non-water soluble, where traditional enzyme-based Limulus amebocyte lysate (LAL) assay cannot be applied. Here we propose a rapid and high throughput ambient ionization mass spectrometric (MS) method using direct analysis in real time (DART) for the evaluation of endotoxin contamination in medical device materials. Large and structurally complex endotoxin instantaneously breaks down into low-mass characteristic fragment ions using DART and is detected by MS in both positive and negative ion modes. This method enables the identification and separation of endotoxin from medical materials with a detection limit of 0.03 ng mL-1 endotoxins in aqueous solution. Ophthalmic viscosurgical device materials including sodium hyaluronate (NaHA), non-water soluble perfluoro-n-octane (PFO) and silicone oil (SO) were spiked with different known concentrations of endotoxin and analyzed by DART MS, where the presence of endotoxin was successfully detected and featured small mass fragment ions were generated for NaHA, PFO and SO as well. Current findings showed the feasibility of measuring endotoxin contamination in medical device materials using DART-MS, which can lead to a one-step analysis of endotoxins in different matrices, avoiding any potential contamination during sample pre-treatment steps.
Collapse
Affiliation(s)
- Hongli Li
- Division of Biology, Chemistry, and Materials Science, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, MD, 20993, United States; Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, Jiangsu Key Laboratory of Biomedical Materials, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China
| | - Victoria M Hitchins
- Division of Biology, Chemistry, and Materials Science, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, MD, 20993, United States
| | - Samanthi Wickramasekara
- Division of Biology, Chemistry, and Materials Science, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, MD, 20993, United States.
| |
Collapse
|
11
|
Mulloy B, Hogwood J, Gray E, Lever R, Page CP. Pharmacology of Heparin and Related Drugs. Pharmacol Rev 2016; 68:76-141. [PMID: 26672027 DOI: 10.1124/pr.115.011247] [Citation(s) in RCA: 227] [Impact Index Per Article: 28.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
Heparin has been recognized as a valuable anticoagulant and antithrombotic for several decades and is still widely used in clinical practice for a variety of indications. The anticoagulant activity of heparin is mainly attributable to the action of a specific pentasaccharide sequence that acts in concert with antithrombin, a plasma coagulation factor inhibitor. This observation has led to the development of synthetic heparin mimetics for clinical use. However, it is increasingly recognized that heparin has many other pharmacological properties, including but not limited to antiviral, anti-inflammatory, and antimetastatic actions. Many of these activities are independent of its anticoagulant activity, although the mechanisms of these other activities are currently less well defined. Nonetheless, heparin is being exploited for clinical uses beyond anticoagulation and developed for a wide range of clinical disorders. This article provides a "state of the art" review of our current understanding of the pharmacology of heparin and related drugs and an overview of the status of development of such drugs.
Collapse
Affiliation(s)
- Barbara Mulloy
- Sackler Institute of Pulmonary Pharmacology, Institute of Pharmaceutical Science, King's College London, London, United Kingdom (B.M., C.P.P.); National Institute for Biological Standards and Control, Potters Bar, Hertfordshire, United Kingdom (J.H., E.G.); and University College London School of Pharmacy, London, United Kingdom (R.L.)
| | - John Hogwood
- Sackler Institute of Pulmonary Pharmacology, Institute of Pharmaceutical Science, King's College London, London, United Kingdom (B.M., C.P.P.); National Institute for Biological Standards and Control, Potters Bar, Hertfordshire, United Kingdom (J.H., E.G.); and University College London School of Pharmacy, London, United Kingdom (R.L.)
| | - Elaine Gray
- Sackler Institute of Pulmonary Pharmacology, Institute of Pharmaceutical Science, King's College London, London, United Kingdom (B.M., C.P.P.); National Institute for Biological Standards and Control, Potters Bar, Hertfordshire, United Kingdom (J.H., E.G.); and University College London School of Pharmacy, London, United Kingdom (R.L.)
| | - Rebecca Lever
- Sackler Institute of Pulmonary Pharmacology, Institute of Pharmaceutical Science, King's College London, London, United Kingdom (B.M., C.P.P.); National Institute for Biological Standards and Control, Potters Bar, Hertfordshire, United Kingdom (J.H., E.G.); and University College London School of Pharmacy, London, United Kingdom (R.L.)
| | - Clive P Page
- Sackler Institute of Pulmonary Pharmacology, Institute of Pharmaceutical Science, King's College London, London, United Kingdom (B.M., C.P.P.); National Institute for Biological Standards and Control, Potters Bar, Hertfordshire, United Kingdom (J.H., E.G.); and University College London School of Pharmacy, London, United Kingdom (R.L.)
| |
Collapse
|
12
|
Sorkin BC, Kuszak AJ, Williamson JS, Hopp DC, Betz JM. The Challenge of Reproducibility and Accuracy in Nutrition Research: Resources and Pitfalls. Adv Nutr 2016; 7:383-9. [PMID: 26980822 PMCID: PMC4785474 DOI: 10.3945/an.115.010595] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Inconsistent and contradictory results from nutrition studies conducted by different investigators continue to emerge, in part because of the inherent variability of natural products, as well as the unknown and therefore uncontrolled variables in study populations and experimental designs. Given these challenges inherent in nutrition research, it is critical for the progress of the field that researchers strive to minimize variability within studies and enhance comparability between studies by optimizing the characterization, control, and reporting of products, reagents, and model systems used, as well as the rigor and reporting of experimental designs, protocols, and data analysis. Here we describe some recent developments relevant to research on plant-derived products used in nutrition research, highlight some resources for optimizing the characterization and reporting of research using these products, and describe some of the pitfalls that may be avoided by adherence to these recommendations.
Collapse
Affiliation(s)
| | | | - John S Williamson
- National Center for Complementary and Integrative Health, NIH, Bethesda, MD
| | - D Craig Hopp
- National Center for Complementary and Integrative Health, NIH, Bethesda, MD
| | | |
Collapse
|
13
|
Lester J, Chandler T, Gemene KL. Reversible Electrochemical Sensor for Detection of High-Charge Density Polyanion Contaminants in Heparin. Anal Chem 2015; 87:11537-43. [DOI: 10.1021/acs.analchem.5b03347] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Affiliation(s)
- Jacob Lester
- Department
of Chemistry, Northern Kentucky University, Nunn Drive, Highland Heights, Kentucky 41099, United States
| | - Timothy Chandler
- Department
of Chemistry, Northern Kentucky University, Nunn Drive, Highland Heights, Kentucky 41099, United States
| | - Kebede L. Gemene
- Department
of Chemistry, Northern Kentucky University, Nunn Drive, Highland Heights, Kentucky 41099, United States
| |
Collapse
|
14
|
Li H, Wickramasekara S, Nemes P. One-Hour Screening of Adulterated Heparin by Simplified Peroxide Digestion and Fast RPIP-LC-MS2. Anal Chem 2015; 87:8424-32. [DOI: 10.1021/acs.analchem.5b01788] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Affiliation(s)
- Hongli Li
- US Food and Drug
Administration (FDA)/CDRH/OSEL/DBCMS, Silver
Spring, Maryland 20993, United States
| | - Samanthi Wickramasekara
- US Food and Drug
Administration (FDA)/CDRH/OSEL/DBCMS, Silver
Spring, Maryland 20993, United States
| | - Peter Nemes
- US Food and Drug
Administration (FDA)/CDRH/OSEL/DBCMS, Silver
Spring, Maryland 20993, United States
- Department
of Chemistry, The George Washington University, Washington, D.C., 20052, United States
| |
Collapse
|
15
|
Shriver Z, Sasisekharan R. Capillary electrophoretic analysis of isolated sulfated polysaccharides to characterize pharmaceutical products. Methods Mol Biol 2015; 1229:161-71. [PMID: 25325952 PMCID: PMC5460761 DOI: 10.1007/978-1-4939-1714-3_15] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
Capillary electrophoresis is a powerful methodology for quantification and structural characterization of highly anionic polysaccharides. Separation of saccharides under conditions of electrophoretic flow, typically achieved under low pH (Ampofo et al., Anal Biochem 199:249-255, 1991; Rhomberg et al., Proc Natl Acad Sci U S A 95:4176-4181, 1998), is charge-based. Resolution of components is often superior to flow-based techniques, such as liquid chromatography. During the heparin contamination crisis, capillary electrophoresis was one of the key methodologies used to identify whether or not heparin lots were contaminated (Guerrini et al., Nat Biotechnol 26:669-675, 2008). Here we describe a method for isolation of sulfated heparin/heparan sulfate saccharides from urine, their digestion by deployment of heparinase enzymes (Ernst et al., Crit Rev Biochem Mol Biol 30:387-444, 1995), resolution of species through use of orthogonal digestions, and analysis of the resulting disaccharides by capillary electrophoresis.
Collapse
Affiliation(s)
- Z Shriver
- Department of Biological Engineering, Koch Institute of Integrative Cancer Research, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA, 02139, USA
| | - R Sasisekharan
- Department of Biological Engineering, Koch Institute of Integrative Cancer Research, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA, 02139, USA
| |
Collapse
|