• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4623409)   Today's Articles (240)   Subscriber (49407)
For: Veder JP, De Marco R, Patel K, Si P, Grygolowicz-Pawlak E, James M, Alam MT, Sohail M, Lee J, Pretsch E, Bakker E. Evidence for a surface confined ion-to-electron transduction reaction in solid-contact ion-selective electrodes based on poly(3-octylthiophene). Anal Chem 2013;85:10495-502. [PMID: 24080025 DOI: 10.1021/ac4024999] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Number Cited by Other Article(s)
1
Kul SM, Chailapakul O, Sagdic O, Ozer T. A smartphone-based sensor for detection of iron and potassium in food and beverage samples. Food Chem 2024;456:139971. [PMID: 38876060 DOI: 10.1016/j.foodchem.2024.139971] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2024] [Revised: 06/01/2024] [Accepted: 06/02/2024] [Indexed: 06/16/2024]
2
Soleimani A, Amirghasemi F, Al-Shami A, Khazaee Nejad S, Tsung A, Wang Y, Lara Galindo S, Parvin D, Olson A, Avishai A, Mousavi MPS. Towards sustainable and humane dairy farming: A low-cost electrochemical sensor for on-site diagnosis of milk fever. Biosens Bioelectron 2024;259:116321. [PMID: 38749287 DOI: 10.1016/j.bios.2024.116321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2024] [Revised: 04/15/2024] [Accepted: 04/19/2024] [Indexed: 06/03/2024]
3
Liu ZH, Cai X, Dai HH, Zhao YH, Gao ZW, Yang YF, Liu YZ, Yang M, Li MQ, Li PH, Huang XJ. Highly Stable Solid Contact Calcium Ion-Selective Electrodes: Rapid Ion-Electron Transduction Triggered by Lipophilic Anions Participating in Redox Reactions of CunS Nanoflowers. Anal Chem 2024;96:9069-9077. [PMID: 38749062 DOI: 10.1021/acs.analchem.4c00590] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/05/2024]
4
la Asunción-Nadal VD, Crespo GA, Cuartero M. Light-induced Delivery of Charged Species using Ion-selective Core-Shell Nanoparticles. Angew Chem Int Ed Engl 2024;63:e202403756. [PMID: 38501244 DOI: 10.1002/anie.202403756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2024] [Revised: 03/09/2024] [Accepted: 03/14/2024] [Indexed: 03/20/2024]
5
Li Y, Li J, Qin W. All-Solid-State Polymeric Membrane Ion-Selective Electrodes Based on NiCo2S4 as a Solid Contact. Anal Chem 2022;94:3574-3580. [PMID: 35175037 DOI: 10.1021/acs.analchem.1c04748] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
6
Ozer T, Henry CS. All-solid-state potassium-selective sensor based on carbon black modified thermoplastic electrode. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2021.139762] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
7
Jaworska E, Maksymiuk K, Michalska A. Ion-selective membrane plasticizer leakage in all-solid-state electrodes – an unobvious way to improve potential reading stability in time. Analyst 2022;147:3298-3304. [DOI: 10.1039/d2an00571a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
8
Choi KR, Chen XV, Hu J, Bühlmann P. Solid-Contact pH Sensor with Covalent Attachment of Ionophores and Ionic Sites to a Poly(decyl methacrylate) Matrix. Anal Chem 2021;93:16899-16905. [PMID: 34878238 DOI: 10.1021/acs.analchem.1c03985] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
9
Rousseau CR, Bühlmann P. Calibration-free potentiometric sensing with solid-contact ion-selective electrodes. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116277] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
10
Ruiz-Gonzalez A, Choy KL. Integration of an Aerosol-Assisted Deposition Technique for the Deposition of Functional Biomaterials Applied to the Fabrication of Miniaturised Ion Sensors. NANOMATERIALS (BASEL, SWITZERLAND) 2021;11:938. [PMID: 33916937 PMCID: PMC8067610 DOI: 10.3390/nano11040938] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/08/2021] [Revised: 04/02/2021] [Accepted: 04/06/2021] [Indexed: 12/02/2022]
11
Cheong YH, Ge L, Lisak G. Highly reproducible solid contact ion selective electrodes: Emerging opportunities for potentiometry - A review. Anal Chim Acta 2021;1162:338304. [PMID: 33926699 DOI: 10.1016/j.aca.2021.338304] [Citation(s) in RCA: 42] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Revised: 01/20/2021] [Accepted: 02/04/2021] [Indexed: 02/07/2023]
12
Mao C, Yuan D, Wang L, Bakker E. Separating boundary potential changes at thin solid contact ion transfer voltammetric membrane electrodes. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2020.114800] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
13
Wagner M, Wagner K, Barnsley JE, Veksha A, Wagner P, Gordon KC, Bobacka J, Wallace GG, Ivaska A, Officer DL, Lisak G. Polyterthiophenes Cross‐Linked with Terpyridyl Metal Complexes for Molecular Architecture of Optically and Electrochemically Tunable Materials. ChemElectroChem 2020. [DOI: 10.1002/celc.202001142] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
14
Lyu Y, Gan S, Bao Y, Zhong L, Xu J, Wang W, Liu Z, Ma Y, Yang G, Niu L. Solid-Contact Ion-Selective Electrodes: Response Mechanisms, Transducer Materials and Wearable Sensors. MEMBRANES 2020;10:membranes10060128. [PMID: 32585903 PMCID: PMC7345918 DOI: 10.3390/membranes10060128] [Citation(s) in RCA: 48] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Revised: 06/15/2020] [Accepted: 06/16/2020] [Indexed: 12/14/2022]
15
Anderson EL, Chopade SA, Spindler B, Stein A, Lodge TP, Hillmyer MA, Bühlmann P. Solid-Contact Ion-Selective and Reference Electrodes Covalently Attached to Functionalized Poly(ethylene terephthalate). Anal Chem 2020;92:7621-7629. [PMID: 32351106 DOI: 10.1021/acs.analchem.0c00296] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
16
Shao Y, Ying Y, Ping J. Recent advances in solid-contact ion-selective electrodes: functional materials, transduction mechanisms, and development trends. Chem Soc Rev 2020;49:4405-4465. [DOI: 10.1039/c9cs00587k] [Citation(s) in RCA: 143] [Impact Index Per Article: 35.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
17
Welbourn R, Clarke S. New insights into the solid–liquid interface exploiting neutron reflectivity. Curr Opin Colloid Interface Sci 2019. [DOI: 10.1016/j.cocis.2019.03.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
18
Zdrachek E, Bakker E. From Molecular and Emulsified Ion Sensors to Membrane Electrodes: Molecular and Mechanistic Sensor Design. Acc Chem Res 2019;52:1400-1408. [PMID: 31017760 DOI: 10.1021/acs.accounts.9b00056] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
19
Effect of oxidation ratio of conducting polymer on potential stability of the conducting polymer-coated electrode in voltammetric cell for the ion transfer. J Electroanal Chem (Lausanne) 2018. [DOI: 10.1016/j.jelechem.2018.07.057] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
20
Ion-Selective Electrodes for Detection of Lead (II) in Drinking Water: A Mini-Review. ENVIRONMENTS 2018. [DOI: 10.3390/environments5090095] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
21
Jarolímová Z, Han T, Mattinen U, Bobacka J, Bakker E. Capacitive Model for Coulometric Readout of Ion-Selective Electrodes. Anal Chem 2018;90:8700-8707. [DOI: 10.1021/acs.analchem.8b02145] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
22
Ghosh T, Chung HJ, Rieger J. All-Solid-State Sodium-Selective Electrode with a Solid Contact of Chitosan/Prussian Blue Nanocomposite. SENSORS (BASEL, SWITZERLAND) 2017;17:E2536. [PMID: 29099804 PMCID: PMC5713653 DOI: 10.3390/s17112536] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/05/2017] [Revised: 10/28/2017] [Accepted: 10/30/2017] [Indexed: 11/24/2022]
23
Guzinski M, Jarvis JM, Perez F, Pendley BD, Lindner E, De Marco R, Crespo GA, Acres RG, Walker R, Bishop J. PEDOT(PSS) as Solid Contact for Ion-Selective Electrodes: The Influence of the PEDOT(PSS) Film Thickness on the Equilibration Times. Anal Chem 2017;89:3508-3516. [DOI: 10.1021/acs.analchem.6b04625] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
24
Cuartero M, Acres RG, De Marco R, Bakker E, Crespo GA. Electrochemical Ion Transfer with Thin Films of Poly(3-octylthiophene). Anal Chem 2016;88:6939-46. [DOI: 10.1021/acs.analchem.6b01800] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
25
Hu J, Stein A, Bühlmann P. Rational design of all-solid-state ion-selective electrodes and reference electrodes. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2015.11.004] [Citation(s) in RCA: 220] [Impact Index Per Article: 27.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
26
SEICHI A, KOZUKA N, KASHIMA Y, TABATA M, GODA T, MATSUMOTO A, IWASAWA N, CITTERIO D, MIYAHARA Y, SUZUKI K. Real-time Monitoring and Detection of Primer Generation-Rolling Circle Amplification of DNA Using an Ethidium Ion-selective Electrode. ANAL SCI 2016;32:505-10. [DOI: 10.2116/analsci.32.505] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
27
Pławińska Ż, Michalska A, Maksymiuk K. Optimization of capacitance of conducting polymer solid contact in ion-selective electrodes. Electrochim Acta 2016. [DOI: 10.1016/j.electacta.2015.11.050] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
28
Cuartero M, Bishop J, Walker R, Acres RG, Bakker E, De Marco R, Crespo GA. Evidence of double layer/capacitive charging in carbon nanomaterial-based solid contact polymeric ion-selective electrodes. Chem Commun (Camb) 2016;52:9703-6. [DOI: 10.1039/c6cc04876e] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
29
Bakker E. Electroanalysis with Membrane Electrodes and Liquid–Liquid Interfaces. Anal Chem 2015;88:395-413. [DOI: 10.1021/acs.analchem.5b04034] [Citation(s) in RCA: 82] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
30
Szűcs J, Lindfors T, Bobacka J, Gyurcsányi RE. Ion-selective Electrodes with 3D Nanostructured Conducting Polymer Solid Contact. ELECTROANAL 2015. [DOI: 10.1002/elan.201500465] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
31
Yuan D, Anthis AHC, Ghahraman Afshar M, Pankratova N, Cuartero M, Crespo GA, Bakker E. All-solid-state potentiometric sensors with a multiwalled carbon nanotube inner transducing layer for anion detection in environmental samples. Anal Chem 2015;87:8640-5. [PMID: 26272001 DOI: 10.1021/acs.analchem.5b01941] [Citation(s) in RCA: 87] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
32
Crespo GA, Cuartero M, Bakker E. Thin Layer Ionophore-Based Membrane for Multianalyte Ion Activity Detection. Anal Chem 2015;87:7729-37. [DOI: 10.1021/acs.analchem.5b01459] [Citation(s) in RCA: 69] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
33
Ye J, Li F, Gan S, Jiang Y, An Q, Zhang Q, Niu L. Using sp2-C dominant porous carbon sub-micrometer spheres as solid transducers in ion-selective electrodes. Electrochem commun 2015. [DOI: 10.1016/j.elecom.2014.10.014] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]  Open
34
Stoikova EE, Sorvin MI, Shurpik DN, Budnikov HC, Stoikov II, Evtugyn GA. Solid‐Contact Potentiometric Sensor Based on Polyaniline and Unsubstituted Pillar[5]Arene. ELECTROANAL 2014. [DOI: 10.1002/elan.201400494] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
35
Zou XU, Zhen XV, Cheong JH, Bühlmann P. Calibration-Free Ionophore-Based Ion-Selective Electrodes With a Co(II)/Co(III) Redox Couple-Based Solid Contact. Anal Chem 2014;86:8687-92. [DOI: 10.1021/ac501625z] [Citation(s) in RCA: 72] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
36
Hu J, Zou XU, Stein A, Bühlmann P. Ion-selective electrodes with colloid-imprinted mesoporous carbon as solid contact. Anal Chem 2014;86:7111-8. [PMID: 24983327 DOI: 10.1021/ac501633r] [Citation(s) in RCA: 123] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
37
Jarolímová Z, Crespo GA, Xie X, Ghahraman Afshar M, Pawlak M, Bakker E. Chronopotentiometric Carbonate Detection with All-Solid-State Ionophore-Based Electrodes. Anal Chem 2014;86:6307-14. [DOI: 10.1021/ac5004163] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
38
Enhancing ion-selective polymeric membrane electrodes by instrumental control. Trends Analyt Chem 2014. [DOI: 10.1016/j.trac.2013.09.014] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA