1
|
A preliminary study of rapid-fire high-throughput metabolite analysis using nano-flow injection/Q-TOFMS. Anal Bioanal Chem 2020; 412:4127-4134. [DOI: 10.1007/s00216-020-02645-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2020] [Revised: 03/17/2020] [Accepted: 04/04/2020] [Indexed: 12/25/2022]
|
2
|
Elpa DP, Prabhu GRD, Wu SP, Tay KS, Urban PL. Automation of mass spectrometric detection of analytes and related workflows: A review. Talanta 2019; 208:120304. [PMID: 31816721 DOI: 10.1016/j.talanta.2019.120304] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2019] [Revised: 08/26/2019] [Accepted: 08/28/2019] [Indexed: 12/13/2022]
Abstract
The developments in mass spectrometry (MS) in the past few decades reveal the power and versatility of this technology. MS methods are utilized in routine analyses as well as research activities involving a broad range of analytes (elements and molecules) and countless matrices. However, manual MS analysis is gradually becoming a thing of the past. In this article, the available MS automation strategies are critically evaluated. Automation of analytical workflows culminating with MS detection encompasses involvement of automated operations in any of the steps related to sample handling/treatment before MS detection, sample introduction, MS data acquisition, and MS data processing. Automated MS workflows help to overcome the intrinsic limitations of MS methodology regarding reproducibility, throughput, and the expertise required to operate MS instruments. Such workflows often comprise automated off-line and on-line steps such as sampling, extraction, derivatization, and separation. The most common instrumental tools include autosamplers, multi-axis robots, flow injection systems, and lab-on-a-chip. Prototyping customized automated MS systems is a way to introduce non-standard automated features to MS workflows. The review highlights the enabling role of automated MS procedures in various sectors of academic research and industry. Examples include applications of automated MS workflows in bioscience, environmental studies, and exploration of the outer space.
Collapse
Affiliation(s)
- Decibel P Elpa
- Department of Applied Chemistry, National Chiao Tung University, 1001 University Rd., Hsinchu, 300, Taiwan; Department of Chemistry, National Tsing Hua University, 101, Section 2, Kuang-Fu Rd., Hsinchu, 30013, Taiwan
| | - Gurpur Rakesh D Prabhu
- Department of Applied Chemistry, National Chiao Tung University, 1001 University Rd., Hsinchu, 300, Taiwan; Department of Chemistry, National Tsing Hua University, 101, Section 2, Kuang-Fu Rd., Hsinchu, 30013, Taiwan
| | - Shu-Pao Wu
- Department of Applied Chemistry, National Chiao Tung University, 1001 University Rd., Hsinchu, 300, Taiwan.
| | - Kheng Soo Tay
- Department of Chemistry, Faculty of Science, University of Malaya, 50603 Kuala Lumpur, Malaysia
| | - Pawel L Urban
- Department of Chemistry, National Tsing Hua University, 101, Section 2, Kuang-Fu Rd., Hsinchu, 30013, Taiwan; Frontier Research Center on Fundamental and Applied Sciences of Matters, National Tsing Hua University, 101, Section 2, Kuang-Fu Rd., Hsinchu, 30013, Taiwan.
| |
Collapse
|
3
|
Electron Ionization LC-MS. ADVANCES IN THE USE OF LIQUID CHROMATOGRAPHY MASS SPECTROMETRY (LC-MS) - INSTRUMENTATION DEVELOPMENTS AND APPLICATIONS 2018. [DOI: 10.1016/bs.coac.2017.06.008] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
4
|
Moreno-González D, Alcántara-Durán J, Gilbert-López B, García-Reyes JF, Molina-Díaz A. Matrix-effect free quantitative liquid chromatography mass spectrometry analysis in complex matrices using nanoflow liquid chromatography with integrated emitter tip and high dilution factors. J Chromatogr A 2017; 1519:110-120. [DOI: 10.1016/j.chroma.2017.09.006] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2017] [Revised: 07/12/2017] [Accepted: 09/03/2017] [Indexed: 12/12/2022]
|
5
|
Delabrière A, Hohenester UM, Colsch B, Junot C, Fenaille F, Thévenot EA. proFIA: a data preprocessing workflow for flow injection analysis coupled to high-resolution mass spectrometry. Bioinformatics 2017; 33:3767-3775. [DOI: 10.1093/bioinformatics/btx458] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2017] [Accepted: 07/12/2017] [Indexed: 02/06/2023] Open
Affiliation(s)
- Alexis Delabrière
- CEA, LIST, Laboratory for Data Analysis and Systems' Intelligence, MetaboHUB, Gif-Sur-Yvette, France
| | - Ulli M Hohenester
- CEA, DRF/JOLIOT/SPI, Laboratoire d'Etude du Métabolisme des Médicaments, MetaboHUB, Gif-Sur-Yvette, France
| | - Benoit Colsch
- CEA, DRF/JOLIOT/SPI, Laboratoire d'Etude du Métabolisme des Médicaments, MetaboHUB, Gif-Sur-Yvette, France
| | - Christophe Junot
- CEA, DRF/JOLIOT/SPI, Laboratoire d'Etude du Métabolisme des Médicaments, MetaboHUB, Gif-Sur-Yvette, France
| | - François Fenaille
- CEA, DRF/JOLIOT/SPI, Laboratoire d'Etude du Métabolisme des Médicaments, MetaboHUB, Gif-Sur-Yvette, France
| | - Etienne A Thévenot
- CEA, LIST, Laboratory for Data Analysis and Systems' Intelligence, MetaboHUB, Gif-Sur-Yvette, France
| |
Collapse
|
6
|
Besil N, Cesio V, Heinzen H, Fernandez-Alba AR. Matrix Effects and Interferences of Different Citrus Fruit Coextractives in Pesticide Residue Analysis Using Ultrahigh-Performance Liquid Chromatography-High-Resolution Mass Spectrometry. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2017; 65:4819-4829. [PMID: 28541668 DOI: 10.1021/acs.jafc.7b00243] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The matrix effects of ethyl acetate extracts from seven different citrus fruits on the determination of 80 pesticide residues using liquid chromatography coupled to high-resolution time-of-flight mass spectrometry (UHPLC-(ESI)-HR-TOF) at 4 GHz resolution mode were studied. Only 20% of the evaluated pesticides showed noticeable matrix effects (ME) due to coelution with natural products between tR = 3 and 11 min. Principal component analysis (PCA) of the detected coextractives grouped the mandarins and the orange varieties, but separated lemon, oranges, and mandarins from each other. Matrix effects were different among species but similar between varieties, forcing the determination of pesticide residues through matrix-matched calibration curves with the same fruit. Twenty-three natural products (synephrine, naringin, poncirin, glycosides of hesperitin, limonin, nomilin, and a few fatty acids, among others) were identified in the analyzed extracts. Twelve of the identified compounds coeluted with 28 of the pesticides under study, causing different matrix effects.
Collapse
Affiliation(s)
- Natalia Besil
- Agrifood Campus of International Excellence (ceiA3), European Union Reference Laboratory for Pesticide Residues in Fruit and Vegetables, Pesticide Residue Research Group, Department of Chemistry and Physics, University of Almeria , La Cañada de San Urbano, 04120 Almeria, Spain
- Grupo de Análisis de Compuestos Traza, Departamento de Quı́mica del Litoral, Facultad de Quı́mica, CENUR Litoral Norte, Universidad de la República (UdelaR) , 11800 Montevideo, Uruguay
- Grupo de Análisis de Compuestos Traza, Cátedra de Farmacognosia y Productos Naturales, Facultad de Quı́mica, Universidad de la República , General Flores 2124, 11800 Montevideo, Uruguay
| | - Verónica Cesio
- Grupo de Análisis de Compuestos Traza, Departamento de Quı́mica del Litoral, Facultad de Quı́mica, CENUR Litoral Norte, Universidad de la República (UdelaR) , 11800 Montevideo, Uruguay
- Grupo de Análisis de Compuestos Traza, Cátedra de Farmacognosia y Productos Naturales, Facultad de Quı́mica, Universidad de la República , General Flores 2124, 11800 Montevideo, Uruguay
| | - Horacio Heinzen
- Grupo de Análisis de Compuestos Traza, Departamento de Quı́mica del Litoral, Facultad de Quı́mica, CENUR Litoral Norte, Universidad de la República (UdelaR) , 11800 Montevideo, Uruguay
- Grupo de Análisis de Compuestos Traza, Cátedra de Farmacognosia y Productos Naturales, Facultad de Quı́mica, Universidad de la República , General Flores 2124, 11800 Montevideo, Uruguay
| | - Amadeo R Fernandez-Alba
- Agrifood Campus of International Excellence (ceiA3), European Union Reference Laboratory for Pesticide Residues in Fruit and Vegetables, Pesticide Residue Research Group, Department of Chemistry and Physics, University of Almeria , La Cañada de San Urbano, 04120 Almeria, Spain
| |
Collapse
|
7
|
Review of analytical methods for the determination of pesticide residues in grapes. J Chromatogr A 2016; 1433:1-23. [DOI: 10.1016/j.chroma.2015.12.076] [Citation(s) in RCA: 160] [Impact Index Per Article: 17.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2015] [Revised: 12/23/2015] [Accepted: 12/28/2015] [Indexed: 11/23/2022]
|
8
|
Abstract
A dynamic development of methodologies of analytical flow injection measurements during four decades since their invention has reinforced the solid position of flow analysis in the arsenal of techniques and instrumentation of contemporary chemical analysis.
Collapse
Affiliation(s)
- Marek Trojanowicz
- Laboratory of Nuclear Analytical Methods
- Institute of Nuclear Chemistry and Technology
- 03-195 Warsaw
- Poland
- Department of Chemistry
| | - Kamila Kołacińska
- Laboratory of Nuclear Analytical Methods
- Institute of Nuclear Chemistry and Technology
- 03-195 Warsaw
- Poland
| |
Collapse
|
9
|
Nanita SC, Kaldon LG. Emerging flow injection mass spectrometry methods for high-throughput quantitative analysis. Anal Bioanal Chem 2015; 408:23-33. [PMID: 26670771 DOI: 10.1007/s00216-015-9193-1] [Citation(s) in RCA: 62] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2015] [Revised: 11/07/2015] [Accepted: 11/12/2015] [Indexed: 01/07/2023]
Abstract
Where does flow injection analysis mass spectrometry (FIA-MS) stand relative to ambient mass spectrometry (MS) and chromatography-MS? Improvements in FIA-MS methods have resulted in fast-expanding uses of this technique. Key advantages of FIA-MS over chromatography-MS are fast analysis (typical run time <60 s) and method simplicity, and FIA-MS offers high-throughput without compromising sensitivity, precision and accuracy as much as ambient MS techniques. Consequently, FIA-MS is increasingly becoming recognized as a suitable technique for applications where quantitative screening of chemicals needs to be performed rapidly and reliably. The FIA-MS methods discussed herein have demonstrated quantitation of diverse analytes, including pharmaceuticals, pesticides, environmental contaminants, and endogenous compounds, at levels ranging from parts-per-billion (ppb) to parts-per-million (ppm) in very complex matrices (such as blood, urine, and a variety of foods of plant and animal origin), allowing successful applications of the technique in clinical diagnostics, metabolomics, environmental sciences, toxicology, and detection of adulterated/counterfeited goods. The recent boom in applications of FIA-MS for high-throughput quantitative analysis has been driven in part by (1) the continuous improvements in sensitivity and selectivity of MS instrumentation, (2) the introduction of novel sample preparation procedures compatible with standalone mass spectrometric analysis such as salting out assisted liquid-liquid extraction (SALLE) with volatile solutes and NH4(+) QuEChERS, and (3) the need to improve efficiency of laboratories to satisfy increasing analytical demand while lowering operational cost. The advantages and drawbacks of quantitative analysis by FIA-MS are discussed in comparison to chromatography-MS and ambient MS (e.g., DESI, LAESI, DART). Generally, FIA-MS sits 'in the middle' between ambient MS and chromatography-MS, offering a balance between analytical capability and sample analysis throughput suitable for broad applications in life sciences, agricultural chemistry, consumer safety, and beyond.
Collapse
Affiliation(s)
- Sergio C Nanita
- DuPont Crop Protection, Stine-Haskell Research Center, 1090 Elkton Road, Newark, DE, 19714, USA.
| | - Laura G Kaldon
- DuPont Crop Protection, Stine-Haskell Research Center, 1090 Elkton Road, Newark, DE, 19714, USA
| |
Collapse
|
10
|
Seemann B, Alon T, Tsizin S, Fialkov AB, Amirav A. Electron ionization LC-MS with supersonic molecular beams--the new concept, benefits and applications. JOURNAL OF MASS SPECTROMETRY : JMS 2015; 50:1252-63. [PMID: 26505770 DOI: 10.1002/jms.3695] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2015] [Revised: 08/19/2015] [Accepted: 08/20/2015] [Indexed: 05/28/2023]
Abstract
A new type of electron ionization LC-MS with supersonic molecular beams (EI-LC-MS with SMB) is described. This system and its operational methods are based on pneumatic spray formation of the LC liquid flow in a heated spray vaporization chamber, full sample thermal vaporization and subsequent electron ionization of vibrationally cold molecules in supersonic molecular beams. The vaporized sample compounds are transferred into a supersonic nozzle via a flow restrictor capillary. Consequently, while the pneumatic spray is formed and vaporized at above atmospheric pressure the supersonic nozzle backing pressure is about 0.15 Bar for the formation of supersonic molecular beams with vibrationally cold sample molecules without cluster formation with the solvent vapor. The sample compounds are ionized in a fly-though EI ion source as vibrationally cold molecules in the SMB, resulting in 'Cold EI' (EI of vibrationally cold molecules) mass spectra that exhibit the standard EI fragments combined with enhanced molecular ions. We evaluated the EI-LC-MS with SMB system and demonstrated its effectiveness in NIST library sample identification which is complemented with the availability of enhanced molecular ions. The EI-LC-MS with SMB system is characterized by linear response of five orders of magnitude and uniform compound independent response including for non-polar compounds. This feature improves sample quantitation that can be approximated without compound specific calibration. Cold EI, like EI, is free from ion suppression and/or enhancement effects (that plague ESI and/or APCI) which facilitate faster LC separation because full separation is not essential. The absence of ion suppression effects enables the exploration of fast flow injection MS-MS as an alternative to lengthy LC-MS analysis. These features are demonstrated in a few examples, and the analysis of the main ingredients of Cannabis on a few Cannabis flower extracts is demonstrated. Finally, the advantages of EI-LC-MS with SMB are listed and discussed.
Collapse
Affiliation(s)
- Boaz Seemann
- School of Chemistry, Tel Aviv University, Tel Aviv, 69978, Israel
| | - Tal Alon
- School of Chemistry, Tel Aviv University, Tel Aviv, 69978, Israel
| | - Svetlana Tsizin
- School of Chemistry, Tel Aviv University, Tel Aviv, 69978, Israel
| | | | - Aviv Amirav
- School of Chemistry, Tel Aviv University, Tel Aviv, 69978, Israel
| |
Collapse
|
11
|
Guo B, Wang M, Liu Y, Zhou J, Dai H, Huang Z, Shen L, Zhang Q, Chen B. Wide-Scope Screening of Illegal Adulterants in Dietary and Herbal Supplements via Rapid Polarity-Switching and Multistage Accurate Mass Confirmation Using an LC-IT/TOF Hybrid Instrument. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2015; 63:6954-6967. [PMID: 26189662 DOI: 10.1021/acs.jafc.5b02222] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
A new analytical strategy was developed that integrates a generic sample preparation into a liquid chromatography-multistage ion trap/time-of-flight mass spectrometry (LC-IT(MS(n))/TOF), allowing for large-scale screening and qualitative confirmation of wide-scope illegal adulterants in different food matrices. Samples were pretreated by a fast single-tube multifunction extraction for accurate multistage mass measurement on the hybrid LC-IT/TOF system. A qualitative validation performed for over 500 analyte-matrix pairs showed the method can reduce most of the matrix effects and achieve a lower limit of confirmation at 0.1 mg/kg for 73% of the target compounds. A unique combination of dual-polarity detection, retention time, isotopic profile, and accurate MS(n) spectra enables more comprehensive and precise confirmation, based on the multiparameter matching by automated library searching against the user-created database. Finally, the applicability of this LC-IT(MS(n))/TOF-based screening procedure for discriminating coeluting isobars, identifying nontarget adulterants, and even tentatively elucidating unexpected species in real samples is demonstrated.
Collapse
Affiliation(s)
| | - Meiling Wang
- §Hunan Academy of Inspection and Quarantine and Food Safety Key Laboratory of Hunan Province, Hunan Entry-Exit Inspection and Quarantine Bureau of China, Changsha 410004, China
| | | | | | - Hua Dai
- §Hunan Academy of Inspection and Quarantine and Food Safety Key Laboratory of Hunan Province, Hunan Entry-Exit Inspection and Quarantine Bureau of China, Changsha 410004, China
| | - Zhiqiang Huang
- §Hunan Academy of Inspection and Quarantine and Food Safety Key Laboratory of Hunan Province, Hunan Entry-Exit Inspection and Quarantine Bureau of China, Changsha 410004, China
| | - Lingling Shen
- #Guangzhou Branch, Shimadzu (China) Co., Limited,7FL,T. P. Plaza, 9/109 Liuhua Road, Guangzhou 510010, China
| | - Qingsheng Zhang
- ΔNational Institutes for Food and Drug Control, Beijing 100050, China
| | | |
Collapse
|
12
|
Lehotay SJ, Sapozhnikova Y, Mol HG. Current issues involving screening and identification of chemical contaminants in foods by mass spectrometry. Trends Analyt Chem 2015. [DOI: 10.1016/j.trac.2015.02.012] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
13
|
Boonjob W, Sklenářová H, Barron L, Solich P, Smith N. Renewable sorbent material for solid phase extraction with direct coupling of sequential injection analysis-bead injection to liquid chromatography-electrospray ionization tandem mass spectrometry. Anal Bioanal Chem 2015; 407:5719-28. [DOI: 10.1007/s00216-015-8752-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2015] [Revised: 04/22/2015] [Accepted: 04/29/2015] [Indexed: 11/30/2022]
|
14
|
Fedeniuk RW, McKenzie D, Mizuno M, Neiser C, O’Byrne C, Shurmer B. Development and validation of determinative and confirmatory LC–MS/MS methodologies for total florfenicol and tulathromycin residues in bovine, equine and porcine kidney, liver and muscle tissues. J Chromatogr B Analyt Technol Biomed Life Sci 2015; 983-984:1-9. [DOI: 10.1016/j.jchromb.2014.12.035] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2014] [Revised: 10/31/2014] [Accepted: 12/29/2014] [Indexed: 11/29/2022]
|
15
|
González-Curbelo MÁ, Lehotay SJ, Hernández-Borges J, Rodríguez-Delgado MÁ. Use of ammonium formate in QuEChERS for high-throughput analysis of pesticides in food by fast, low-pressure gas chromatography and liquid chromatography tandem mass spectrometry. J Chromatogr A 2014; 1358:75-84. [PMID: 25047819 DOI: 10.1016/j.chroma.2014.06.104] [Citation(s) in RCA: 74] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2014] [Revised: 06/27/2014] [Accepted: 06/30/2014] [Indexed: 11/28/2022]
Abstract
The "quick, easy, cheap, effective, rugged, and safe" (QuEChERS) approach to sample preparation is widely applied in pesticide residue analysis, but the use of magnesium sulfate and other nonvolatile compounds for salting out in the method is not ideal for mass spectrometry. In this study, we developed and evaluated three new different versions of the QuEChERS method using more volatile salts (ammonium chloride and ammonium formate and acetate buffers) to induce phase separation and extraction of 43 representative pesticide analytes of different classes. Fast low-pressure gas chromatography tandem mass spectrometry (LPGC-MS/MS) and liquid chromatography (LC)-MS/MS were used for analysis. The QuEChERS AOAC Official Method 2007.01 was also tested for comparison purposes. Of the studied methods, formate buffering using 7.5g of ammonium formate and 15mL of 5% (v/v) formic acid in acetonitrile for the extraction of 15g of sample (5g for wheat grain) provided the best performance and practical considerations. Method validation was carried out with and without the use of dispersive solid-phase extraction for cleanup, and no significant differences were observed for the majority of pesticides. The method was demonstrated in quantitative analysis for GC- and LC-amenable pesticides in 4 representative food matrices (apple, lemon, lettuce, and wheat grain). With the typical exceptions of certain pH-dependent and labile pesticides, 90-110% recoveries and <10% RSD were obtained. Detection limits were mostly <5ng/g, which met the general need to determine pesticide concentrations as low as 10ng/g for monitoring purposes in food applications.
Collapse
Affiliation(s)
- Miguel Ángel González-Curbelo
- US Department of Agriculture, Agricultural Research Service, 600 East Mermaid Lane, Wyndmoor, PA 19038, USA; Departamento de Química Analítica, Nutrición y Bromatología, Facultad de Química, Universidad de La Laguna, Avenida Astrofísico Francisco Sánchez s/n, 38206 La Laguna (Tenerife), España
| | - Steven J Lehotay
- US Department of Agriculture, Agricultural Research Service, 600 East Mermaid Lane, Wyndmoor, PA 19038, USA.
| | - Javier Hernández-Borges
- Departamento de Química Analítica, Nutrición y Bromatología, Facultad de Química, Universidad de La Laguna, Avenida Astrofísico Francisco Sánchez s/n, 38206 La Laguna (Tenerife), España
| | - Miguel Ángel Rodríguez-Delgado
- Departamento de Química Analítica, Nutrición y Bromatología, Facultad de Química, Universidad de La Laguna, Avenida Astrofísico Francisco Sánchez s/n, 38206 La Laguna (Tenerife), España
| |
Collapse
|