1
|
Han T, Wang Y, Bai H, Zhang H, Liu J. A lamellar V 2O 3@C composite for aluminium-ion batteries displaying long cycle life and low-temperature tolerance. Chem Commun (Camb) 2022; 58:7172-7175. [PMID: 35670315 DOI: 10.1039/d2cc01931k] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Rechargeable aluminum-ion (Al-ion) batteries have important potential for fast charging and safe energy-storage systems. Here, we develop a composite composed of lamellar V2O3@C nanosheets, which displays high electrochemical properties as an Al-ion battery cathode. The unique structure is conducive to the rapid insertion and release of Al3+ ions, electrolyte infiltration, and improved conductivity. After cycling 500 times, the capacity exceeds 242.5 mA h g-1. Under a low temperature of -10 °C, the capacity remains 150.8 mA h g-1, and the Coulombic efficiency is higher than 98.8%. The V2O3@C also exhibits a good reversibility verified by using ex situ X-ray powder diffraction patterns, while the constant current intermittent titration technology shows a low reaction barrier, which indicates that the lamellar composite presented here could find significant applications for engineering many high-performance energy-storage systems.
Collapse
Affiliation(s)
- Tianli Han
- Key Laboratory of Functional Molecular Solids (Ministry of Education), Anhui Provincial Engineering Laboratory for New-Energy Vehicle Battery Energy-Storage Materials, College of Chemistry and Materials Science, Anhui Normal University, Wuhu, Anhui 241002, P. R. China.
| | - Yan Wang
- Key Laboratory of Functional Molecular Solids (Ministry of Education), Anhui Provincial Engineering Laboratory for New-Energy Vehicle Battery Energy-Storage Materials, College of Chemistry and Materials Science, Anhui Normal University, Wuhu, Anhui 241002, P. R. China.
| | - Haiyuan Bai
- Key Laboratory of Functional Molecular Solids (Ministry of Education), Anhui Provincial Engineering Laboratory for New-Energy Vehicle Battery Energy-Storage Materials, College of Chemistry and Materials Science, Anhui Normal University, Wuhu, Anhui 241002, P. R. China.
| | - Huigang Zhang
- National Laboratory of Solid State Microstructures, College of Engineering and Applied Sciences, Nanjing University, Nanjing, Jiangsu 210093, P. R. China.,State Key Laboratory of Multiphase Complex Systems, Institute of Process Engineering, Chinese Academy of Sciences, Beijing 100190, P. R. China
| | - Jinyun Liu
- Key Laboratory of Functional Molecular Solids (Ministry of Education), Anhui Provincial Engineering Laboratory for New-Energy Vehicle Battery Energy-Storage Materials, College of Chemistry and Materials Science, Anhui Normal University, Wuhu, Anhui 241002, P. R. China.
| |
Collapse
|
2
|
Microwave Synthesis, Characterization and Perspectives of Wood Pencil-Derived Carbon. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12010410] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
More than 14 billion pencils are manufactured and used globally every year. On average, a pencil is discarded after 60% of its original length has been depleted. In the present work we propose a simple and affordable way of converting this non-neglectable amount of waste into added value carbon product. In particular, we demonstrate the microwave synthesis of carbon from the wood pencil with and without chemical activation. This could be a process stage before the final recycling of the expensive graphite core. In the latter case, irradiation of the wood pencil in a domestic microwave oven heats up the pencil’s graphite core, thus inducing carbonization of its wood casing. The carbonized product consists of amorphous carbon nanosheets having relatively low surface area. However, if the wood pencil is soaked in 50% KOH aqueous solution prior to microwave irradiation, a significantly higher surface area of carbon is obtained, consisting of irregular-shaped porous particles. Consequently, the obtained carbon can easily decolorize a methylene blue aqueous solution, can be used to make pocket warmers or gunpowder, and lastly, serves as an excellent adsorbent towards Cr(VI) removal from water, showing a maximum adsorption capacity of 70–75 mg/g within 24 h at 23 °C, pH = 3.
Collapse
|
3
|
Bio-Surfactant Assisted Aqueous Exfoliation of High-Quality Few-Layered Graphene. CRYSTALS 2021. [DOI: 10.3390/cryst11080944] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Realizing the efficacy of the liquid-phase exfoliation technique to obtain a greater quantity of graphene, this study demonstrates a cost-effective technique of bio-surfactant-assisted liquid-phase exfoliation of few-layer graphene (FLG) with a low defect ratio. An ultrasonic bath without any toxic chemicals or chemical modification was employed to exfoliate the graphene at room temperature. Several state-of-the-art characterization techniques such as TEM, AFM, XRD UV-Vis, and Raman spectroscopy were used to confirm the presence of the graphene. The dispersion exhibits a typical Tyndall scattering to the red laser beam. After a 7-h sonication of the dispersion, followed by a centrifugation frequency of 500 rpm for half an hour, the graphene concentration was found to be 1.2 mg/mL. The concentration decreases monotonically with an increase in the frequency, as a higher frequency causes sedimentation of the larger flakes or removes the adsorbed surfactant molecules from the graphene structures that collapse the graphene sheets into the graphite. The presence of an amino acid head-group in the surfactant facilitated exfoliation in an aqueous solution at well below the critical micelle concentration (CMC) of the surfactant. The product demonstrates all characteristic features of an FLG system. The TEM and AFM image reveals large-area graphene with a wrinkle-free surface; these morphological properties are confirmed by XRD and Raman spectroscopy. This study suggests that a sonication-induced process with a biocompatible surfactant can produce a cheap, large-surface-area graphene system for a wide range of applications. Moreover, the use of a probe sonicator as an alternative to the bath-type sonicator, together with the demonstrated technique, may reduce the time needed, and leads to a manifold increase in the yield.
Collapse
|
4
|
Chung IM, Kim SH. Biological and biomedical (14)C-accelerator mass spectrometry and graphitization of carbonaceous samples. Analyst 2013; 138:3347-55. [PMID: 23626987 DOI: 10.1039/c3an00077j] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Accelerator mass spectrometry (AMS) is the ultimate technique for measuring rare isotopes in small samples. Biological and biomedical applications of (14)C-AMS (bio-(14)C-AMS) commenced in the early 1990s and are now widely used in many research fields including pharmacology, toxicology, food, and nutrition. For accurate, precise, and reproducible bio-(14)C-AMS analysis, the graphitization step in sample preparation is the most critical step. So, various sample preparation methods for a process called graphitization have been reported for specific applications. Catalytic graphitization using either a flame-sealed borosilicate tube or a septa-sealed vial is a popular sample preparation method for bio-(14)C-AMS. In this review, we introduce the AMS system, especially for bio-(14)C-AMS. In addition, we also review the graphitization method for bio-(14)C-AMS to promote further understanding and improvement of sample preparation for this technique. Examples of catalytic graphitization methods over the past two decades are described.
Collapse
Affiliation(s)
- Ill-Min Chung
- Department of Applied Bioscience, College of Life and Environmental Science, Konkuk University, Seoul 143-701, Republic of Korea
| | | |
Collapse
|
5
|
Food authenticity using natural carbon isotopes (12C, 13C, 14C) in grass-fed and grain-fed beef. Food Sci Biotechnol 2012. [DOI: 10.1007/s10068-012-0040-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022] Open
|
6
|
Kim SH, Chuang JC, Kelly PB, Clifford AJ. Carbon isotopes profiles of human whole blood, plasma, red blood cells, urine and feces for biological/biomedical 14C-accelerator mass spectrometry applications. Anal Chem 2011; 83:3312-8. [PMID: 21452856 DOI: 10.1021/ac103038s] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Radiocarbon ((14)C) is an ideal tracer for in vivo human ADME (absorption, distribution, metabolism, elimination) and PBPK (physiological-based pharmacokinetic) studies. Living plants peferentially incorporate atmospheric (14)CO(2) versus (13)CO(2) versus (12)CO(2), which result in unique signature. Furthermore, plants and the food chains they support also have unique carbon isotope signatures. Humans, at the top of the food chain, consequently acquire isotopic concentrations in the tissues and body fluids depending on their dietary habits. In preparation of ADME and PBPK studies, 12 healthy subjects were recruited. The human baseline (specific to each individual and their diet) total carbon (TC) and carbon isotope (13)C (δ(13)C) and (14)C (F(m)) were quantified in whole blood (WB), plasma, washed red blood cell (RBC), urine, and feces. TC (mg of C/100 μL) in WB, plasma, RBC, urine, and feces were 11.0, 4.37, 7.57, 0.53, and 1.90, respectively. TC in WB, RBC, and feces was higher in men over women, P < 0.05. Mean δ(13)C were ranked low to high as follows: feces < WB = plasma = RBC = urine, P < 0.0001. δ(13)C was not affected by gender. Our analytic method shifted δ(13)C by only ±1.0 ‰ ensuring our F(m) measurements were accurate and precise. Mean F(m) were ranked low to high as follows: plasma = urine < WB = RBC = feces, P < 0.05. F(m) in feces was higher for men over women, P < 0.05. Only in WB, (14)C levels (F(m)) and TC were correlated with one another (r = 0.746, P < 0.01). Considering the lag time to incorporate atmospheric (14)C into plant foods (vegetarian) and or then into animal foods (nonvegetarian), the measured F(m) of WB in our population (recruited April 2009) was 1.0468 ± 0.0022 (mean ± SD), and the F(m) of WB matched the (extrapolated) atmospheric F(m) of 1.0477 in 2008. This study is important in presenting a procedure to determine a baseline for a study group for human ADME and PBPK studies using (14)C as a tracer.
Collapse
Affiliation(s)
- Seung-Hyun Kim
- Department of Nutrition, University of California Davis, 95616, USA
| | | | | | | |
Collapse
|
7
|
Accelerator mass spectrometry-enabled studies: current status and future prospects. Bioanalysis 2011; 2:519-41. [PMID: 20440378 DOI: 10.4155/bio.09.188] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023] Open
Abstract
Accelerator mass spectrometry is a detection platform with exceptional sensitivity compared with other bioanalytical platforms. Accelerator mass spectrometry (AMS) is widely used in archeology for radiocarbon dating applications. Early exploration of the biological and pharmaceutical applications of AMS began in the early 1990s. AMS has since demonstrated unique problem-solving ability in nutrition science, toxicology and pharmacology. AMS has also enabled the development of new applications, such as Phase 0 microdosing. Recent development of AMS-enabled applications has transformed this novelty research instrument to a valuable tool within the pharmaceutical industry. Although there is now greater awareness of AMS technology, recognition and appreciation of the range of AMS-enabled applications is still lacking, including study-design strategies. This review aims to provide further insight into the wide range of AMS-enabled applications. Examples of studies conducted over the past two decades will be presented, as well as prospects for the future of AMS.
Collapse
|
8
|
Kim SH, Kelly PB, Ortalan V, Browning ND, Clifford AJ. Quality of graphite target for biological/biomedical/environmental applications of 14C-accelerator mass spectrometry. Anal Chem 2010; 82:2243-52. [PMID: 20163100 PMCID: PMC2837469 DOI: 10.1021/ac9020769] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2009] [Accepted: 02/03/2010] [Indexed: 11/28/2022]
Abstract
Catalytic graphitization for (14)C-accelerator mass spectrometry ((14)C-AMS) produced various forms of elemental carbon. Our high-throughput Zn reduction method (C/Fe = 1:5, 500 degrees C, 3 h) produced the AMS target of graphite-coated iron powder (GCIP), a mix of nongraphitic carbon and Fe(3)C. Crystallinity of the AMS targets of GCIP (nongraphitic carbon) was increased to turbostratic carbon by raising the C/Fe ratio from 1:5 to 1:1 and the graphitization temperature from 500 to 585 degrees C. The AMS target of GCIP containing turbostratic carbon had a large isotopic fractionation and a low AMS ion current. The AMS target of GCIP containing turbostratic carbon also yielded less accurate/precise (14)C-AMS measurements because of the lower graphitization yield and lower thermal conductivity that were caused by the higher C/Fe ratio of 1:1. On the other hand, the AMS target of GCIP containing nongraphitic carbon had higher graphitization yield and better thermal conductivity over the AMS target of GCIP containing turbostratic carbon due to optimal surface area provided by the iron powder. Finally, graphitization yield and thermal conductivity were stronger determinants (over graphite crystallinity) for accurate/precise/high-throughput biological, biomedical, and environmental (14)C-AMS applications such as absorption, distribution, metabolism, elimination (ADME), and physiologically based pharmacokinetics (PBPK) of nutrients, drugs, phytochemicals, and environmental chemicals.
Collapse
Affiliation(s)
| | | | | | | | - Andrew J. Clifford
- To whom correspondence should be addressed. E-mail: . Tel: 530-752-3376. Fax: 530-752-8966
| |
Collapse
|
9
|
Kim SH, Kelly PB, Clifford AJ. Accelerator mass spectrometry targets of submilligram carbonaceous samples using the high-throughput Zn reduction method. Anal Chem 2009; 81:5949-54. [PMID: 19548665 PMCID: PMC2710856 DOI: 10.1021/ac900406r] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
Abstract
The high-throughput Zn reduction method was developed and optimized for various biological/biomedical accelerator mass spectrometry (AMS) applications of mg of C size samples. However, high levels of background carbon from the high-throughput Zn reduction method were not suitable for sub-mg of C size samples in environmental, geochronology, and biological/biomedical AMS applications. This study investigated the effect of background carbon mass (mc) and background 14C level (Fc) from the high-throughput Zn reduction method. Background mc was 0.011 mg of C and background Fc was 1.5445. Background subtraction, two-component mixing, and expanded formulas were used for background correction. All three formulas accurately corrected for backgrounds to 0.025 mg of C in the aerosol standard (NIST SRM 1648a). Only the background subtraction and the two-component mixing formulas accurately corrected for backgrounds to 0.1 mg of C in the IAEA-C6 and -C7 standards. After the background corrections, our high-throughput Zn reduction method was suitable for biological (diet)/biomedical (drug) and environmental (fine particulate matter) applications of sub-mg of C samples (≥ 0.1 mg of C) in keeping with a balance between throughput (270 samples/day/analyst) and sensitivity/accuracy/precision of AMS measurement. The development of a high-throughput method for examination of ≥ 0.1 mg of C size samples opens up a range of applications for 14C AMS studies. While other methods do exist for ≥ 0.1 mg of C size samples, the low throughput has made them cost prohibitive for many applications.
Collapse
Affiliation(s)
- Seung-Hyun Kim
- Department of Nutrition, University of California Davis, One Shields Avenue, Davis, California 95616, USA
| | | | | |
Collapse
|