1
|
Rojas D, Torricelli D, Cuartero M, Crespo GA. 3D-Printed Transducers for Solid Contact Potentiometric Ion Sensors: Improving Reproducibility by Fabrication Automation. Anal Chem 2024; 96:15572-15580. [PMID: 39303277 PMCID: PMC11447669 DOI: 10.1021/acs.analchem.4c02098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/22/2024]
Abstract
3D printing technology has become attractive in the development of electrochemical sensors as it offers automation in fabrication, customization on-demand, and reproducibility, among other features. Nonetheless, to date, solid contact potentiometric ion sensors have remained overlooked using this technology. Thus, the novelty of this work relies on demonstrating for the first time the usefulness of the multimaterial 3D printing approach to manufacture potentiometric ion-selective electrodes. The significance is indeed twofold. First, we discovered that by using the polyethylene terephthalate glycol (PETg) and polylactic acid-carbon black (PLA-CB) filaments together with a rational electrode design containing a well to accommodate the ion-selective membrane, a tight seal among all of the sensing materials is obtained. Importantly, this has mainly impacted the electrode-to-electrode reproducibility (ERSD0 ± 3 mV). Second, 75 ready-to-use electrodes can be printed in less than 3.5 h in a completely automated manner at a cost of ∼0.32 €/sensor. This feature may positively impact the suitability of further scaled-up production as well as the possibility of application in low-resource contexts. Overall, the presented outcomes are expected to encourage certain research directions to adopt using multimaterial 3D-printing approaches for producing highly reproducible solid contact potentiometric ion-selective electrodes, but are not restricted to them.
Collapse
Affiliation(s)
- Daniel Rojas
- UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain
| | - Dario Torricelli
- UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain
| | - María Cuartero
- UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain
- Department of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, SE-114 28 Stockholm, Sweden
| | - Gastón A Crespo
- UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain
- Department of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, SE-114 28 Stockholm, Sweden
| |
Collapse
|
2
|
Chipangura Y, Komal M, Brandao VSM, Sedmak C, Choi JS, Swisher SL, Bühlmann P, Stein A. Nanoporous Carbon Materials as Solid Contacts for Microneedle Ion-Selective Sensors. ACS APPLIED MATERIALS & INTERFACES 2024; 16:44428-44439. [PMID: 39146498 DOI: 10.1021/acsami.4c07683] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/17/2024]
Abstract
Continuous sensing of biomarkers, such as potassium ions or pH, in wearable patches requires miniaturization of ion-selective sensor electrodes. Such miniaturization can be achieved by using nanostructured carbon materials as solid contacts in microneedle-based ion-selective and reference electrodes. Here we compare three carbon materials as solid contacts: colloid-imprinted mesoporous (CIM) carbon microparticles with ∼24-28 nm mesopores, mesoporous carbon nanospheres with 3-9 nm mesopores, and Super P carbon black nanoparticles without internal porosity but with textural mesoporosity in particle aggregates. We compare the effects of carbon architecture and composition on specific capacitance of the material, on the ability to incorporate ion-selective membrane components in the pores, and on sensor performance. Functioning K+ and H+ ion-selective electrodes and reference electrodes were obtained with gold-coated stainless-steel microneedles using all three types of carbon. The sensors gave near-Nernstian responses in clinically relevant concentration ranges, were free of potentially detrimental water layers, and showed no response to O2. They all exhibited sufficiently low long-term potential drift values to permit calibration-free, continuous operation for close to 1 day. In spite of the different specific capacitances and pore architecture of the three types of carbon, no significant difference in potential stability for K+ ion sensing was observed between electrodes that used each material. In the observed drift values, factors other than the carbon solid contact are likely to play a role, too. However, for pH sensing, electrodes with CIM as a carbon solid contact, which had the highest specific capacitance and best access to the pores, exhibited better long-term stability than electrodes with the other carbon materials.
Collapse
Affiliation(s)
- Yevedzo Chipangura
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| | - Maria Komal
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| | - Vilma S M Brandao
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| | - Christopher Sedmak
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| | - Jung Suk Choi
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| | - Sarah L Swisher
- Department of Electrical and Computer Engineering, University of Minnesota, 200 Union St. SE, Minneapolis, Minnesota 55455, United States
| | - Philippe Bühlmann
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| | - Andreas Stein
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| |
Collapse
|
3
|
Choi KR, Honig ML, Bühlmann P. Ion-Selective Potentiometry with Plasma-Initiated Covalent Attachment of Sensing Membranes onto Inert Polymeric Substrates and Carbon Solid Contacts. Anal Chem 2024; 96:4702-4708. [PMID: 38451778 DOI: 10.1021/acs.analchem.4c00204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/09/2024]
Abstract
The physical delamination of the sensing membrane from underlying electrode bodies and electron conductors limits sensor lifetimes and long-term monitoring with ion-selective electrodes (ISEs). To address this problem, we developed two plasma-initiated graft polymerization methods that attach ionophore-doped polymethacrylate sensing membranes covalently to high-surface-area carbons that serve as the conducting solid contact as well as to polypropylene, poly(ethylene-co-tetrafluoroethylene), and polyurethane as the inert polymeric electrode body materials. The first strategy consists of depositing the precursor solution for the preparation of the sensing membranes onto the platform substrates with the solid contact carbon, followed by exposure to an argon plasma, which results in surface-grafting of the in situ polymerized sensing membrane. Using the second strategy, the polymeric platform substrate is pretreated with argon plasma and subsequently exposed to ambient oxygen, forming hydroperoxide groups on the surface. Those functionalities are then used for the initiation of photoinitiated graft polymerization of the sensing membrane. Attenuated total reflection-Fourier transform infrared spectroscopy, water contact angle measurements, and delamination tests confirm the covalent attachment of the in situ polymerized sensing membranes onto the polymeric substrates. Using membrane precursor solutions comprising, in addition to decyl methacrylate and a cross-linker, also 2-(diisopropylamino)ethyl methacrylate as a covalently attachable H+ ionophore and tetrakis(pentafluorophenyl)borate as ionic sites, both plasma-based fabrication methods produced electrodes that responded to pH in a Nernstian fashion, with the high selectivity expected for ionophore-based ISEs.
Collapse
Affiliation(s)
- Kwangrok R Choi
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455, United States
| | - Madeline L Honig
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455, United States
| | - Philippe Bühlmann
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455, United States
| |
Collapse
|
4
|
Chipangura YE, Spindler BD, Bühlmann P, Stein A. Design Criteria for Nanostructured Carbon Materials as Solid Contacts for Ion-Selective Sensors. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2309778. [PMID: 38105339 DOI: 10.1002/adma.202309778] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 12/05/2023] [Indexed: 12/19/2023]
Abstract
The ability to miniaturize ion-selective sensors that enable microsensor arrays and wearable sensor patches for ion detection in environmental or biological samples requires all-solid-state sensors with solid contacts for transduction of an ion activity into an electrical signal. Nanostructured carbon materials function as effective solid contacts for this purpose. They can also contribute to improved potential signal stability, reducing the need for frequent sensor calibration. In this Perspective, the structural features of various carbon-based solid contacts described in the literature and their respective abilities to reduce potential drift during long-term, continuous measurements are compared. These carbon materials include nanoporous carbons with various architectures, carbon nanotubes, carbon black, graphene, and graphite-based solid contacts. The effects of accessibility of ionophores, ionic sites, and other components of an ion-selective membrane to the internal or external carbon surfaces are discussed, because this impacts double-layer capacitance and potential drift. The effects of carbon composition on water-layer formation are also considered, which is another contributor to potential drift during long-term measurements. Recommendations regarding the selection of solid contacts and considerations for their characterization and testing in solid-contact ion-selective electrodes are provided.
Collapse
Affiliation(s)
- Yevedzo E Chipangura
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, MN, 55454, USA
| | - Brian D Spindler
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, MN, 55454, USA
| | - Philippe Bühlmann
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, MN, 55454, USA
| | - Andreas Stein
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, MN, 55454, USA
| |
Collapse
|
5
|
TABATA M, MIYAHARA Y. Control of interface functions in solid-state biosensors for stable detection of molecular recognition. PROCEEDINGS OF THE JAPAN ACADEMY. SERIES B, PHYSICAL AND BIOLOGICAL SCIENCES 2024; 100:32-56. [PMID: 38199246 PMCID: PMC10864167 DOI: 10.2183/pjab.100.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Accepted: 09/25/2023] [Indexed: 01/12/2024]
Abstract
Significant progress has been achieved in the field of solid-state biosensors over the past 50 years. Various sensing devices with high-density integration and flexible configuration, as well as new applications for clinical diagnosis and healthcare, have been developed using blood, serum, and other body fluids such as sweat, tears, and saliva. A high-density array of ion-sensitive field effect transistors was developed by exploiting the advantages of advanced semiconductor technologies and commercialized in combination with an enzymatic primer extension reaction as a DNA sequencer in 2011. Different types of materials such as inorganic materials, metals, polymers, and biomolecules are mixed together on the surface of the gate while maintaining their own functions; therefore, compatibility among different materials has to be optimized so that the best detection performance of solid-state biosensors, including stability and reliability, is achieved as designed. Solid-state biosensors are suitable for the rapid, cost-effective, and noninvasive identification of biomarkers at various timepoints over the course of a disease.
Collapse
Affiliation(s)
- Miyuki TABATA
- Graduate School of Bio-Applications and Systems Engineering, Tokyo University of Agriculture and Technology, Koganei, Tokyo, Japan
| | - Yuji MIYAHARA
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, Tokyo, Japan
| |
Collapse
|
6
|
Spindler BD, Graf KI, Dong XIN, Kim M, Chen XV, Bühlmann P, Stein A. Influence of the Composition of Plasticizer-Free Silicone-Based Ion-Selective Membranes on Signal Stability in Aqueous and Blood Plasma Samples. Anal Chem 2023; 95:12419-12426. [PMID: 37552138 DOI: 10.1021/acs.analchem.3c02074] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/09/2023]
Abstract
Solid-contact ion-selective electrodes (SC-ISEs) in direct long-term contact with physiological samples must be biocompatible and resistant to biofouling, but most wearable SC-ISEs proposed to date contain plasticized poly(vinyl chloride) (PVC) membranes, which have poor biocompatibility. Silicones are a promising alternative to plasticized PVC because of their excellent biocompatibility, but little work has been done to study the relationship between silicone composition and ISE performance. To address this, we prepared and tested K+ SC-ISEs with colloid-imprinted mesoporous (CIM) carbon as the solid contact and three different condensation-cured silicones: a custom silicone prepared in-house (Silicone 1), a commercial silicone (Dow 3140, Silicone 2), and a commercial fluorosilicone (Dow 730, Fluorosilicone 1). SC-ISEs prepared with each of these polymers and the ionophore valinomycin and added ionic sites exhibited Nernstian responses, excellent selectivities, and signal drifts as low as 3 μV/h in 1 mM KCl solution. All ISEs maintained Nernstian response slopes and had only very slightly worsened selectivities after 41 h exposure to porcine plasma (log KK,Na values of -4.56, -4.58, and -4.49, to -4.04, -4.00, and -3.90 for Silicone 1, Silicone 2, and Fluorosilicone 1, respectively), confirming that these sensors retain the high selectivity that makes them suitable for use in physiological samples. When immersed in porcine plasma, the SC-ISEs exhibited emf drifts that were still fairly low but notably larger than when measurements were performed in pure water. Interestingly, despite the very similar structures of these matrix polymers, SC-ISEs prepared with Silicone 2 showed lower drift in porcine blood plasma (-55 μV/h, over 41 h) compared to Silicone 1 (-495 μV/h) or Fluorosilicone 1 (-297 μV/h).
Collapse
Affiliation(s)
- Brian D Spindler
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55454, United States
| | - Katerina I Graf
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55454, United States
| | - Xin I N Dong
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55454, United States
| | - Minog Kim
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55454, United States
| | - Xin V Chen
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55454, United States
| | - Philippe Bühlmann
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55454, United States
| | - Andreas Stein
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55454, United States
| |
Collapse
|
7
|
Dong XIN, Spindler BD, Kim M, Stein A, Bühlmann P. Spontaneous Mesoporosity-Driven Sequestration of Ionic Liquids from Silicone-Based Reference Electrode Membranes. ACS Sens 2023; 8:1774-1781. [PMID: 37043696 DOI: 10.1021/acssensors.3c00085] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/14/2023]
Abstract
Nanopore-driven sequestration of ionic liquids from a silicone membrane is presented, a phenomenon that has not been reported previously. Reference electrodes with ionic liquid doped polydimethylsiloxane (PDMS) reference membranes and colloid-imprinted mesoporous carbon (CIM) as solid contact are not functional unless special attention is paid to the porosity of the solid contact. In the fabrication of such reference electrodes, a solution of a hydroxyl-terminated silicone oligomer, ionic liquid, cross-linking reagent, and polymerization catalyst is deposited on top of the carbon layer, rapidly filling the pores of the CIM carbon. The catalyzed polymerization curing of the silicone quickly results in cross-linking of the hydroxyl-terminated polydimethylsiloxane oligomers, forming structures that are too large to penetrate the CIM carbon pores. Therefore, as solvent evaporation from the top of freshly prepared membranes drives the diffusional transport of solvent toward that membrane surface, the solvent molecules that leave the CIM carbon pores can only be replaced by the ionic liquid. This depletes the ionic liquid in the reference membrane that overlies the CIM carbon solid contact and increases the membrane resistance by up to 3 orders of magnitude, rendering the devices dysfunctional. This problem can be avoided by presaturating the CIM carbon with ionic liquid prior to the deposition of the solution that contains the silicone oligomers and ionic liquid. Alternatively, a high amount of ionic liquid can be added into the membrane solution to account for the size-selective sequestration of ionic liquid into the carbon pores. Either way, a wide variety of ionic liquids can be used to prepare PDMS-based reference electrodes with CIM carbon as a solid contact. A similar depletion of the K+ ionophore BME-44 from ion-selective silicone membranes was observed too, highlighting that the depletion of active ingredients from polymeric ion-selective and reference membranes due to interactions with high surface area solid contacts may be a more common phenomenon that so far has been overlooked.
Collapse
Affiliation(s)
- Xin I N Dong
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| | - Brian D Spindler
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| | - Minog Kim
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| | - Andreas Stein
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| | - Philippe Bühlmann
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| |
Collapse
|
8
|
Kalasin S, Surareungchai W. Challenges of Emerging Wearable Sensors for Remote Monitoring toward Telemedicine Healthcare. Anal Chem 2023; 95:1773-1784. [PMID: 36629753 DOI: 10.1021/acs.analchem.2c02642] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
Digitized telemedicine tools with the Internet of Things (IoT) started advancing into our daily lives and have been incorporated with commercial wearable gadgets for noninvasive remote health monitoring. The newly established tools have been steered toward a new era of decentralized healthcare. The advancement of a telemedicine wearable monitoring system has attracted enormous interest in the multimodal big data acquisition of real-time physiological and biochemical information via noninvasive methods for any health-related industries. The expectation of telemedicine wearable creation has been focused on early diagnosis of multiple diseases and minimizing the cost of high-tech and invasive treatments. However, only limited progress has been directed toward the development of telemedicine wearable sensors. This Perspective addresses the advancement of these wearable sensors that encounter multiple challenges on the forefront and technological gaps hampering the realization of health monitoring at molecular levels related to smart materials mostly limited to single use, issues of selectivity to analytes, low sensitivity to targets, miniaturization, and lack of artificial intelligence to perform multiple tasks and secure big data transfer. Sensor stability with minimized signal drift, on-body sensor reusability, and long-term continuous health monitoring provides key analytical challenges. This Perspective also focuses on, promotes, and highlights wearable sensors with a distinct capability to interconnect with telemedicine healthcare for physical sensing and multiplex sensing at deeper levels. Moreover, it points out some critical challenges in different material aspects and promotes what it will take to advance the current state-of-art wearable sensors for telemedicine healthcare. Ultimately, this Perspective is to draw attention to some potential blind spots of wearable technology development and to inspire further development of this integrated technology in mitigating multimorbidity in aging societies through health monitoring at molecular levels to identify signs of diseases.
Collapse
Affiliation(s)
- Surachate Kalasin
- Faculty of Science and Nanoscience & Nanotechnology Graduate Program, King Mongkut's University of Technology Thonburi, 10140 Bangkok, Thailand
| | - Werasak Surareungchai
- Pilot Plant Research and Development Laboratory, King Mongkut's University of Technology Thonburi, 10150 Bangkok, Thailand
- School of Bioresource and Technology, King Mongkut's University of Technology Thonburi, 10150 Bangkok, Thailand
| |
Collapse
|
9
|
Activity-Dependent Fluctuations in Interstitial [K +]: Investigations Using Ion-Sensitive Microelectrodes. MOLECULES (BASEL, SWITZERLAND) 2023; 28:molecules28020523. [PMID: 36677581 PMCID: PMC9865121 DOI: 10.3390/molecules28020523] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 12/31/2022] [Accepted: 01/02/2023] [Indexed: 01/06/2023]
Abstract
In the course of action potential firing, all axons and neurons release K+ from the intra- cellular compartment into the interstitial space to counteract the depolarizing effect of Na+ influx, which restores the resting membrane potential. This efflux of K+ from axons results in K+ accumulation in the interstitial space, causing depolarization of the K+ reversal potential (EK), which can prevent subsequent action potentials. To ensure optimal neuronal function, the K+ is buffered by astrocytes, an energy-dependent process, which acts as a sink for interstitial K+, absorbing it at regions of high concentration and distributing it through the syncytium for release in distant regions. Pathological processes in which energy production is compromised, such as anoxia, ischemia, epilepsy and spreading depression, can lead to excessive interstitial K+ accumulation, disrupting sensitive trans-membrane ion gradients and attenuating neuronal activity. The changes that occur in interstitial [K+] resulting from both physiological and pathological processes can be monitored accurately in real time using K+-sensitive microelectrodes, an invaluable tool in electrophysiological studies.
Collapse
|
10
|
Gan S, Liao C, Liang R, Du S, Zhong L, Tang Y, Han T, Bao Y, Sun Z, Ma Y, Niu L. A Solid-Contact Reference Electrode Based on Silver/Silver Organic Insoluble Salt for Potentiometric Ion Sensing. ACS MEASUREMENT SCIENCE AU 2022; 2:568-575. [PMID: 36785773 PMCID: PMC9886000 DOI: 10.1021/acsmeasuresciau.2c00036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Revised: 07/31/2022] [Accepted: 08/01/2022] [Indexed: 06/18/2023]
Abstract
Solid-contact ion-selective electrodes are a type of ion measurement devices that have been focused in wearable biotechnology based on the features of miniaturization and integration. However, the solid-contact reference electrodes (SC-REs) remain relatively less focused compared with numerous working (or indicator) electrodes. Most SC-REs in wearable sensors rely on Ag/AgCl reference electrodes with solid electrolytes, for example, the hydrophilic electrolyte salts in polymer matrix, but face the risk of electrolyte leakage. Herein, we report a type of SC-REs based on the silver/silver tetraphenylborate (Ag/AgTPB) organic insoluble electrode. The SC-RE consists of a Ag substrate, a solid contact (AgTPB), and a plasticized poly(vinyl chloride) (PVC) membrane containing the hydrophobic organic salt of tetrabutylammonium tetraphenylborate (TBATPB). The potentiometric measurements demonstrated that the SC-RE of Ag/AgTPB/PVC-TBATPB showed a reproducible standard potential in various electrolytes and disclosed high long-term stability. This SC-RE was further fabricated on a flexible substrate and integrated into all-solid-state wearable potentiometric ion sensor for sweat Cl- monitoring.
Collapse
Affiliation(s)
- Shiyu Gan
- Guangzhou
Key Laboratory of Sensing Materials & Devices, Center for Advanced
Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Chunxian Liao
- Guangzhou
Key Laboratory of Sensing Materials & Devices, Center for Advanced
Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Rongfeng Liang
- Guangzhou
Key Laboratory of Sensing Materials & Devices, Center for Advanced
Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Sanyang Du
- Guangzhou
Key Laboratory of Sensing Materials & Devices, Center for Advanced
Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Lijie Zhong
- Guangzhou
Key Laboratory of Sensing Materials & Devices, Center for Advanced
Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Yitian Tang
- Guangzhou
Key Laboratory of Sensing Materials & Devices, Center for Advanced
Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Tingting Han
- Guangzhou
Key Laboratory of Sensing Materials & Devices, Center for Advanced
Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Yu Bao
- Guangzhou
Key Laboratory of Sensing Materials & Devices, Center for Advanced
Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Zhonghui Sun
- Guangzhou
Key Laboratory of Sensing Materials & Devices, Center for Advanced
Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Yingming Ma
- Guangzhou
Key Laboratory of Sensing Materials & Devices, Center for Advanced
Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Li Niu
- Guangzhou
Key Laboratory of Sensing Materials & Devices, Center for Advanced
Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| |
Collapse
|
11
|
Kai Tang, Liang Y, Xu R, Zhang Y, Xie Z, Hu B, Kang J, Cao Y, Xiang M. Effects of Molecular Structure on Crystallization Kinetics of Poly(ethylene terephthalate-co-neopentyl glycol). POLYMER SCIENCE SERIES A 2022. [DOI: 10.1134/s0965545x22030129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
12
|
Jiang T, Yin B, Liu X, Yang L, Pang H, Song J, Wu S. Porous carbon-based robust, durable, and flexible electrochemical device for K + detection in sweat. Analyst 2022; 147:1144-1151. [PMID: 35180282 DOI: 10.1039/d1an02322e] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Ion sensors are attracting attention for real-time ion monitoring in biological fluids, which requires the development of sensitive, stable, flexible, robust and durable ion-selective electrodes (ISEs) and reference electrodes (REs). In this paper, a highly robust and durable ion sensor was prepared by coating polymer membranes on porous carbon electrodes. A high sensitivity of 58.6 mV per decade with a rapid response time of 0.8 s, and a negligible potential drift less than 1.4 mV h-1 were obtained simultaneously. In addition, after six washing cycles, the K+ ion sensors still have an average sensitivity of 53.2 mV per decade. Importantly, the polymer membrane permeated and packed the porous structure tightly, and thus the ion sensors presented outstanding robustness and durability. The Nernst slope of the K+ ion response fluctuated from 60.2 to 57.9 mV per decade between 0° and 60° bending angles. Repeated bending for 8000 cycles did not result in the delamination of the sensing and reference membranes or reduction of the sensitivity (57.4 mV per decade). Furthermore, five kinds of flexible reference electrodes (LEC, bare Ag, bare Ag/AgCl, PVB + NaCl on Ag/AgCl, PVC/agarose + NaCl on Ag/AgCl) were fabricated and evaluated in terms of the sensitivity for Cl- and long-term stability. Finally, the flexible K+ ion sensor was integrated with microfluidic channels and connected to a portable electrochemical workstation to realize the real-time analysis of human sweat.
Collapse
Affiliation(s)
- Tingting Jiang
- School of Chemical Engineering, Dalian University of Technology, Dalian 116023, PR China.
| | - Bing Yin
- School of Chemical Engineering, Dalian University of Technology, Dalian 116023, PR China.
| | - Xiaobo Liu
- School of Chemical Engineering, Dalian University of Technology, Dalian 116023, PR China.
| | - Lihui Yang
- School of Chemical Engineering, Dalian University of Technology, Dalian 116023, PR China.
| | - Hongyu Pang
- School of Chemical Engineering, Dalian University of Technology, Dalian 116023, PR China.
| | - Jie Song
- School of Chemical Engineering, Dalian University of Technology, Dalian 116023, PR China.
| | - Shuo Wu
- School of Chemical Engineering, Dalian University of Technology, Dalian 116023, PR China.
| |
Collapse
|
13
|
Choi KR, Chen XV, Hu J, Bühlmann P. Solid-Contact pH Sensor with Covalent Attachment of Ionophores and Ionic Sites to a Poly(decyl methacrylate) Matrix. Anal Chem 2021; 93:16899-16905. [PMID: 34878238 DOI: 10.1021/acs.analchem.1c03985] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
With a view to improving the sensor lifetime, solid-contact ion-selective electrodes (ISEs) were prepared with a plasticizer-free and cross-linked poly(decyl methacrylate) matrix, to which only the ionic sites, only the ionophore, or both the ionic sites and ionophore were covalently attached. In earlier work with covalently attached ionophores or ionic sites, it was difficult to discount the presence of ionophores or ionic site impurities that were not covalently attached to the polymer backbone because the reagents used to introduce the ionophore or ionic sites had high hydrophobicities. In this work, we deliberately chose readily available hydrophilic reagents for the introduction of covalently attached H+ ionophores with tertiary amino groups and covalently attached sulfonate groups as ionic sites. This simplified the synthesis and made it possible to thoroughly remove ionophores and ionic sites not covalently attached to the polymer backbone. Our results confirm the expectation that hydrophobic ISE membranes with both covalently attached ionophores and ionic sites have impractically long response times. In contrast, ISEs with either covalently attached H+ ionophores or covalently attached ionic sites responded to pH with quick Nernstian responses and high selectivity. Both conventional plasticized poly(vinyl chloride) (PVC)-based ISEs and the new poly(decyl methacrylate) membranes were exposed to 90 °C heat for 2 h, 10% ethanol for 1 day, or undiluted blood serum for 5 days. In all three cases, the poly(decyl methacrylate) ISEs exhibited properties superior to conventional PVC-based ISEs, confirming the advantages of the covalent attachment.
Collapse
Affiliation(s)
- Kwangrok R Choi
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis Minnesota 55455, United States
| | - Xin V Chen
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis Minnesota 55455, United States
| | - Jinbo Hu
- Emerson Automation Solutions, 6021 Innovation Blvd, Shakopee Minnesota 55379, United States
| | - Philippe Bühlmann
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis Minnesota 55455, United States
| |
Collapse
|
14
|
Rousseau CR, Bühlmann P. Calibration-free potentiometric sensing with solid-contact ion-selective electrodes. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116277] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
15
|
Using MoS2/Fe3O4 as Ion-Electron Transduction Layer to Manufacture All-Solid-State Ion-Selective Electrode for Determination of Serum Potassium. CHEMOSENSORS 2021. [DOI: 10.3390/chemosensors9070155] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
As an essential electrolyte for the human body, the potassium ion (K+) plays many physiological roles in living cells, so the rapid and accurate determination of serum K+ is of great significance. In this work, we developed a solid-contact ion-selective electrode (SC-ISE) using MoS2/Fe3O4 composites as the ion-to-electron transducer to determine serum K+. The potential response measurement of MoS2/Fe3O4/K+-ISE shows a Nernst response by a slope of 55.2 ± 0.1 mV/decade and a low detection limit of 6.3 × 10−6 M. The proposed electrode exhibits outstanding resistance to the interference of O2, CO2, light, and water layer formation. Remarkably, it also presents a high performance in potential reproducibility and long-term stability.
Collapse
|
16
|
Affiliation(s)
- Elena Zdrachek
- Department of Inorganic and Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland
| | - Eric Bakker
- Department of Inorganic and Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland
| |
Collapse
|
17
|
Lyu Y, Gan S, Bao Y, Zhong L, Xu J, Wang W, Liu Z, Ma Y, Yang G, Niu L. Solid-Contact Ion-Selective Electrodes: Response Mechanisms, Transducer Materials and Wearable Sensors. MEMBRANES 2020; 10:membranes10060128. [PMID: 32585903 PMCID: PMC7345918 DOI: 10.3390/membranes10060128] [Citation(s) in RCA: 48] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Revised: 06/15/2020] [Accepted: 06/16/2020] [Indexed: 12/14/2022]
Abstract
Wearable sensors based on solid-contact ion-selective electrodes (SC-ISEs) are currently attracting intensive attention in monitoring human health conditions through real-time and non-invasive analysis of ions in biological fluids. SC-ISEs have gone through a revolution with improvements in potential stability and reproducibility. The introduction of new transducing materials, the understanding of theoretical potentiometric responses, and wearable applications greatly facilitate SC-ISEs. We review recent advances in SC-ISEs including the response mechanism (redox capacitance and electric-double-layer capacitance mechanisms) and crucial solid transducer materials (conducting polymers, carbon and other nanomaterials) and applications in wearable sensors. At the end of the review we illustrate the existing challenges and prospects for future SC-ISEs. We expect this review to provide readers with a general picture of SC-ISEs and appeal to further establishing protocols for evaluating SC-ISEs and accelerating commercial wearable sensors for clinical diagnosis and family practice.
Collapse
Affiliation(s)
- Yan Lyu
- School of Civil Engineering, c/o Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (Y.L.); (Y.B.); (L.Z.); (W.W.); (Z.L.); (Y.M.)
| | - Shiyu Gan
- School of Civil Engineering, c/o Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (Y.L.); (Y.B.); (L.Z.); (W.W.); (Z.L.); (Y.M.)
- Correspondence: (S.G.); (L.N.)
| | - Yu Bao
- School of Civil Engineering, c/o Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (Y.L.); (Y.B.); (L.Z.); (W.W.); (Z.L.); (Y.M.)
| | - Lijie Zhong
- School of Civil Engineering, c/o Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (Y.L.); (Y.B.); (L.Z.); (W.W.); (Z.L.); (Y.M.)
| | - Jianan Xu
- State Key Laboratory of Electroanalytical Chemistry, c/o Engineering Laboratory for Modern Analytical Techniques, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, China;
- University of Chinese Academy of Sciences, Beijing 100039, China
| | - Wei Wang
- School of Civil Engineering, c/o Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (Y.L.); (Y.B.); (L.Z.); (W.W.); (Z.L.); (Y.M.)
| | - Zhenbang Liu
- School of Civil Engineering, c/o Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (Y.L.); (Y.B.); (L.Z.); (W.W.); (Z.L.); (Y.M.)
| | - Yingming Ma
- School of Civil Engineering, c/o Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (Y.L.); (Y.B.); (L.Z.); (W.W.); (Z.L.); (Y.M.)
| | - Guifu Yang
- School of Information Science and Technology, Northeast Normal University, Changchun 130117, China;
| | - Li Niu
- School of Civil Engineering, c/o Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (Y.L.); (Y.B.); (L.Z.); (W.W.); (Z.L.); (Y.M.)
- MOE Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Guangzhou University, Guangzhou 510006, China
- Correspondence: (S.G.); (L.N.)
| |
Collapse
|