1
|
Courtney M, Carreno-Molina OM, Ren CL. Design Guidelines of Free-Flow Counterflow Gradient Focusing Device for Protein Fractionation. Electrophoresis 2025. [PMID: 39964910 DOI: 10.1002/elps.8106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2024] [Accepted: 01/30/2025] [Indexed: 02/20/2025]
Abstract
Free-flow counterflow gradient focusing (FF-CGF) is a promising tool for protein fractionation. This work establishes guidelines to construct an FF-CGF system suitable for preparative applications. Numerical and analytical computations are undertaken to investigate design parameters, including device geometry, flow conditions, sample concentration, and applied voltage. This collective information serves as a design tool to guide the fabrication of the device, which, in this case, is constructed from polymethyl methacrylate (PMMA) and double-sided tape. Furthermore, the design tool also supports device operation and provides insights into the expected resolution and throughput. Experimental results, which demonstrated the ability of the designed chip to generate a uniform counterflow gradient while separating small molecules and proteins, validated the accuracy of the design guidelines.
Collapse
Affiliation(s)
- Matthew Courtney
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, Ontario, Canada
| | | | - Carolyn L Ren
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, Ontario, Canada
| |
Collapse
|
2
|
Mahmud S, Ramproshad S, Deb R, Dutta D. A review of the zone broadening contributions in free-flow electrophoresis. Electrophoresis 2023; 44:1519-1538. [PMID: 37548630 DOI: 10.1002/elps.202300062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 06/20/2023] [Accepted: 07/18/2023] [Indexed: 08/08/2023]
Abstract
The broadening of analyte streams, as they migrate through a free-flow electrophoresis (FFE) channel, often limits the resolving power of FFE separations. Under laminar flow conditions, such zonal spreading occurs due to analyte diffusion perpendicular to the direction of streamflow and variations in the lateral distance electrokinetically migrated by the analyte molecules. Although some of the factors that give rise to these contributions are inherent to the FFE method, others originate from non-idealities in the system, such as Joule heating, pressure-driven crossflows, and a difference between the electrical conductivities of the sample stream and background electrolyte. The injection process can further increase the stream width in FFE separations but normally influencing all analyte zones to an equal extent. Recently, several experimental and theoretical works have been reported that thoroughly investigate the various contributions to stream variance in an FFE device for better understanding, and potentially minimizing their magnitudes. In this review article, we carefully examine the findings from these studies and discuss areas in which more work is needed to advance our comprehension of the zone broadening contributions in FFE assays.
Collapse
Affiliation(s)
- Sakur Mahmud
- Department of Chemistry, University of Wyoming, Laramie, Wyoming, USA
| | - Sarker Ramproshad
- Department of Chemistry, University of Wyoming, Laramie, Wyoming, USA
| | - Rajesh Deb
- Department of Chemistry, University of Wyoming, Laramie, Wyoming, USA
| | - Debashis Dutta
- Department of Chemistry, University of Wyoming, Laramie, Wyoming, USA
| |
Collapse
|
3
|
Courtney M, Glawdel T, Ren CL. Investigating peak dispersion in free-flow counterflow gradient focusing due to electroosmotic flow. Electrophoresis 2022; 44:646-655. [PMID: 36502493 DOI: 10.1002/elps.202200230] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Revised: 11/09/2022] [Accepted: 11/24/2022] [Indexed: 12/14/2022]
Abstract
Free-flow electrophoresis (FFE) has the ability to continuously separate charged solutes from complex biological mixtures. Recently, a free-flow counterflow gradient focusing mechanism has been introduced to FFE, and it offers the potential for improved resolution and versatility. However, further investigation is needed to understand the solute dispersion at the focal position. Therefore, the goal of this work is to model the impact of electroosmotic flow, which is found to produce a pressure-driven backflow to maintain the fixed counterflow inputs. Like the counterflow, this backflow has a parabolic velocity profile that must be considered when predicting the concentration distribution of a given solute. After the model is established, preliminary experimental results are presented for a qualitative comparison. Results demonstrate a reasonable agreement at low applied voltages and provide a strong framework for future experimental validation.
Collapse
Affiliation(s)
- Matthew Courtney
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, Ontario, Canada
| | - Tomasz Glawdel
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, Ontario, Canada
| | - Carolyn L Ren
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, Ontario, Canada
| |
Collapse
|
4
|
Multi-channel contactless conductivity detection device for online detection of free-flow electrophoresis separation. Se Pu 2022; 40:384-390. [PMID: 35362686 PMCID: PMC9404027 DOI: 10.3724/sp.j.1123.2021.11011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
现有自由流电泳(FFE)装置因不具备在线检测功能,其实用性仍然存在明显不足。针对这一问题,该工作发展了一种多通道电容耦合式非接触电导检测(MC-C4D)装置并开发了自动测量软件。MC-C4D装置采用了并行分时的非接触电导检测技术,即由多个同样的非接触电导检测模块并行排列,而单个电导检测模块又由多个非接触电导检测池组成,采用模拟开关切换这些检测池,能够分时检测流经相应检测池溶液的电导率。多个电导检测模块的检测池总数等于FFE的组分数,它们分别串行接入到FFE各流路中,这样MC-C4D装置就可在线并行分时在线测量各组分溶液的电导率。为验证所设计MC-C4D装置的检测性能,采用配制的氯化钾标准溶液作为检测对象对MC-C4D装置进行了标定和测试。实验数据表明,MC-C4D装置电导率检测范围为0.015~2.5 mS/cm,检出限(LOD)为0.002 mS/cm,日内相对标准偏差(RSD, n=3)为2.31%,测量相对误差(RE)为3.03%和通道间测量相对偏差为1.60%,这些参数表明该装置检测范围较大,LOD低,重复性好,准确性高,通道间测量相对偏差小。另外,将MC-C 4D装置应用于往复式自由流等电聚焦电泳(RFFIEF)在蛋白质聚焦过程中对各组分溶液电导率进行实时在线检测,结果表明,所开发的MC-C4D装置不仅可实现对FFE各组分溶液电导率的实时在线检测,而且还可在RFFIEF实验中辅助掌握分离的实验进度,提高FFE装置的实用性。
Collapse
|
5
|
Microfluidic free-flow electrophoresis: a promising tool for protein purification and analysis in proteomics. J IND ENG CHEM 2022. [DOI: 10.1016/j.jiec.2022.02.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
6
|
Courtney M, Glawdel T, Ren CL. Investigating peak dispersion in free-flow counterflow gradient focusing. Electrophoresis 2021; 43:776-784. [PMID: 34679205 DOI: 10.1002/elps.202100203] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 09/23/2021] [Accepted: 10/05/2021] [Indexed: 11/07/2022]
Abstract
Free-flow electrophoresis (FFE) enables the continuous separation and collection of charged solutes, and as a result, it has drawn interest as both a preparative and an analytical tool for biological applications. Recently, a free-flow counterflow gradient focusing (FF-CGF) mechanism has been proposed with the goal of improving the resolution and versatility of FFE. To realize this potential, the factors that influence solute dispersion deserve further attention, including the gradient strength and the parabolic profile of the counterflow. Therefore, the goal of this work is to develop a theoretical model to study the interplay between these factors and molecular diffusion. Overall, an asymmetric solute distribution emerges for a wide range of parameters, and this behavior can be characterized with an exponentially modified Gaussian function. Results show that FF-CGF can achieve high-resolution separations, with the potential for high-throughput protein purification. Moreover, this work provides a practical guide for optimizing experimental conditions, as well as a strong framework for understanding and developing FF-CGF further.
Collapse
Affiliation(s)
- Matthew Courtney
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, Ontario, N2L3G1, Canada
| | - Tomasz Glawdel
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, Ontario, N2L3G1, Canada
| | - Carolyn L Ren
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, Ontario, N2L3G1, Canada
| |
Collapse
|
7
|
Kochmann S, Ivanov NA, Lucas KS, Krylov SN. Topino: A Graphical Tool for Quantitative Assessment of Molecular Stream Separations. Anal Chem 2021; 93:9980-9985. [PMID: 34255479 DOI: 10.1021/acs.analchem.1c01229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
In molecular-stream separation (MSS), a stream of a multicomponent mixture is separated into multiple streams of individual components. Quantitative evaluation of MSS data has been a bottleneck in MSS for decades as there was no conventional way to present the data in a reproducible and uniform fashion. The roots of the problem were in the multidimensional nature of MSS data; even in the ideal case of steady-state separation, the data is three-dimensional: intensity and two spatial coordinates. We recently found a way to reduce the dimensionality via presenting the MSS data in a polar coordinate system and convoluting the data via integration of intensity along the radius axis. The result of this convolution is an angulagram, a simple 2D plot presenting integrated intensity vs angle. Not only does an angulagram simplify the visual assessment, but it also allows the determination of three quantitative parameters characterizing the quality of MSS: stream width, stream linearity, and stream deflection. Reliably converting an MSS image into an angulagram and accurately determining the stream parameters requires an advanced and user-friendly software tool. In this technical note, we introduce such a tool: the open-source software Topino available at https://github.com/Schallaven/topino. Topino is a stand-alone program with a modern graphical user interface that allows processing an MSS image in a fast (<2 min) and straightforward way. The robustness and ruggedness of Topino were confirmed by comparing the results obtained by three users. Topino removes the analytical bottleneck in MSS and will be an indispensable tool for MSS users with varying levels of experience.
Collapse
Affiliation(s)
- Sven Kochmann
- Department of Chemistry and Centre for Research on Biomolecular Interactions, York University, Toronto, Ontario M3J 1P3, Canada
| | - Nikita A Ivanov
- Department of Chemistry and Centre for Research on Biomolecular Interactions, York University, Toronto, Ontario M3J 1P3, Canada
| | - Kevin S Lucas
- Department of Chemistry and Centre for Research on Biomolecular Interactions, York University, Toronto, Ontario M3J 1P3, Canada
| | - Sergey N Krylov
- Department of Chemistry and Centre for Research on Biomolecular Interactions, York University, Toronto, Ontario M3J 1P3, Canada
| |
Collapse
|
8
|
Abstract
该文为2020年毛细管电泳(capillary electrophoresis, CE)技术年度回顾。归纳总结了以“capillary electrophoresis-mass spectrometry”或“capillary isoelectric focusing”或“micellar electrokinetic chromatography”或“capillary electrophoresis”为关键词在ISI Web of Science数据库中进行主题检索得到的2020年CE技术相关研究论文222篇,以及中文期刊《分析化学》和《色谱》中CE技术相关的研究论文37篇。对2020年影响因子(IF)≥5.0的Analytical Chemistry, Food Chemistry, Analytica Chimica Acta和Talanta等13本期刊的38篇文章报道的科研工作作了逐一介绍;对IF<5.0的期刊中CE技术报道较为集中的Journal of Chromatography A和Electrophoresis两本分析化学类期刊发表40篇文章中的代表性内容作了综合介绍;对重要的中文期刊《分析化学》出版的“核酸适配体专刊”和《色谱》出版的2期CE技术专刊所收录的37篇文章中的工作作了总体介绍。总体来说,2020年CE技术发展趋势仍以毛细管电泳-质谱(CE-MS)的新方法和新应用最为突出,主要集中在CE-MS与电化学检测、固相萃取以及多种毛细管电泳模式的联用方面,CE-MS接口相关的报道较前几年有所减少;常规CE技术则以胶束电动毛细管色谱(MEKC)在复杂样本分析、浓缩富集应用为主,尤其在食品和药品等复杂基质样本分析方面的报道较为集中;此外,我国CE相关领域专家学者的科研成果涵盖了CE在生命科学、临床医学、医药研发、环境科学、天然产物、食品分析等领域的应用,代表了国内CE科研应用水平和现状。
Collapse
|