1
|
Li Y, Miao S, Tan J, Zhang Q, Chen DDY. Capillary Electrophoresis: A Three-Year Literature Review. Anal Chem 2024; 96:7799-7816. [PMID: 38598751 DOI: 10.1021/acs.analchem.4c00857] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/12/2024]
Affiliation(s)
- Yueyang Li
- Department of Chemistry, University of British Columbia, Vancouver, British Columbia V6T 1Z1, Canada
| | - Siyu Miao
- Department of Chemistry, University of British Columbia, Vancouver, British Columbia V6T 1Z1, Canada
| | - Jiahua Tan
- Department of Chemistry, University of British Columbia, Vancouver, British Columbia V6T 1Z1, Canada
| | - Qi Zhang
- School of Pharmacy, Jiangsu University, Zhenjiang, Jiangsu 212013, P. R. China
| | - David Da Yong Chen
- Department of Chemistry, University of British Columbia, Vancouver, British Columbia V6T 1Z1, Canada
| |
Collapse
|
2
|
Casto-Boggess LD, Holland LA. Fluorescent parallel electrophoresis assay of enzyme inhibition. Anal Chim Acta 2024; 1296:342268. [PMID: 38401944 PMCID: PMC10911858 DOI: 10.1016/j.aca.2024.342268] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2023] [Revised: 01/14/2024] [Accepted: 01/17/2024] [Indexed: 02/26/2024]
Abstract
BACKGROUND Enzyme inhibitors comprise the largest class of pharmaceutical compounds. The discovery and development of new enzyme inhibitor drug candidates depends on sensitive tools to quantify inhibition constants, Ki, for the most promising candidates. A high throughput, automated, and miniaturized approach to measure inhibition is reported. In this technique enzyme inhibition occurs within a 16 nL nanogel reaction zone that is integrated into a capillary. The reaction and electrophoresis separation are completed in under 10 min. The nanoliter enzyme reaction zones are easily positioned inside a standard separation capillary by pseudo-immobilizing enzymes within a thermally reversible nanogel. RESULTS This report optimizes and validates a capillary nanogel electrophoresis reaction and separation with a multi-capillary array instrument. Inhibitor constants are determined for the neuraminidase enzyme to quantify the effect of the transition state analog, 2,3-dehydro-2-deoxy-N-acetylneuraminic acid (DANA), as well as the inhibitor Siastatin B. With the multi-capillary array assay replicate Ki values are determined to be 5.7 ± 0.1 μM (n = 3) and 9.2 ± 0.2 μM (n = 3) for DANA and Siastatin B, respectively. The enzyme reaction in each separation capillary converts the substrate to a product in real time. The nanogel is used under suppressed electroosmotic flow, sustains enzyme function, and is easily filled and replaced by changing the capillary temperature. Using laser-induced fluorescence allows the determination to be achieved with substrate concentrations well below the Michaelis-Menten constant, making the method independent of the substrate concentration and therefore a more easily implemented assay. SIGNIFICANCE A lower measurement cost is realized when the reaction volume is miniaturized because the amounts of enzyme, substrate and inhibitor are reduced. Fast enzyme reactions are possible because of the small reaction volume. With a multi-capillary array, the inhibition assay is achieved in a fraction of the time required for traditional methods. The separation-based assay can even be applied to labeled substrates not cleaned up following the labeling reaction.
Collapse
Affiliation(s)
- Laura D Casto-Boggess
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, 26506, USA
| | - Lisa A Holland
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, 26506, USA.
| |
Collapse
|
3
|
Ward CL, Cornejo MA, Peli Thanthri SH, Linz TH. A review of electrophoretic separations in temperature-responsive Pluronic thermal gels. Anal Chim Acta 2023; 1276:341613. [PMID: 37573098 DOI: 10.1016/j.aca.2023.341613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Revised: 07/10/2023] [Accepted: 07/11/2023] [Indexed: 08/14/2023]
Abstract
Gel electrophoresis is a ubiquitous bioanalytical technique used in research laboratories to validate protein and nucleic acid samples. Polyacrylamide and agarose have been the gold standard gel materials for decades, but an alternative class of polymer has emerged with potentially superior performance. Pluronic thermal gels are water-soluble polymers that possess the unique ability to undergo a change in viscosity in response to changing temperature. Thermal gels can reversibly convert between low-viscosity liquids and high-viscosity solid gels using temperature as an adjustable parameter. The properties of thermal gels provide unmatched flexibility as a dynamic separations matrix to measure analytes ranging from small molecules to cells. This review article describes the physical and chemical properties of Pluronic thermal gels to provide a fundamental overview of polymer behavior. The performance of thermal gels is then reviewed to highlight their applications as a gel matrix for electrokinetic separations in capillary, microfluidic, and slab gel formats. The use of dynamic temperature-responsive gels in bioanalytical separations is an underexplored area of research but one that holds exciting potential to achieve performance unattainable with conventional static polymers.
Collapse
Affiliation(s)
- Cassandra L Ward
- Department of Chemistry, Wayne State University, Detroit, MI, USA; Lumigen Instrument Center, Wayne State University, Detroit, MI, USA.
| | - Mario A Cornejo
- Department of Chemistry, Wayne State University, Detroit, MI, USA
| | | | - Thomas H Linz
- Department of Chemistry, Wayne State University, Detroit, MI, USA.
| |
Collapse
|
4
|
Peli Thanthri SH, Linz TH. Controlling the separation of native proteins with temperature in thermal gel transient isotachophoresis. Anal Bioanal Chem 2023; 415:4163-4172. [PMID: 36151350 PMCID: PMC10033466 DOI: 10.1007/s00216-022-04331-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Revised: 08/31/2022] [Accepted: 09/07/2022] [Indexed: 11/25/2022]
Abstract
Polyacrylamide gel electrophoresis (PAGE) is a ubiquitous technique used in biochemical research laboratories to characterize protein samples. Despite its popularity, PAGE is relatively slow and provides limited separation resolution, especially for native proteins. This report describes the development of a microfluidic thermal gel transient isotachophoresis (TG-tITP) method to rapidly separate native proteins with high resolution. Thermal gels were employed as a separations matrix because of their unique ability to change viscosity in response to temperature. Proteins were added into thermal gel and loaded into a microfluidic device. Electrolyte optimization was conducted to achieve robust tITP to isotachophoretically preconcentrate proteins and then electrophoretically separate them. Electropherograms were collected through both time and distance to enable both small and large proteins to be measured within a single analysis. The effects of temperature were evaluated and found to exhibit a pronounced effect on the separation. Temperature gradients were then employed to alter thermal gel viscosity over time to maximize separation resolution between proteins. The results herein demonstrate how gradient TG-tITP achieves rapid, high-performance separations of native proteins. This analysis provided a wide mass range (6-464 kDa) with two-fold higher resolution than native PAGE while requiring 15,000-fold less protein loading and providing five-fold faster analysis times.
Collapse
Affiliation(s)
| | - Thomas H Linz
- Department of Chemistry, Wayne State University, 5101 Cass Ave, Detroit, MI, 48202, USA.
| |
Collapse
|
5
|
Holland LA, Casto-Boggess LD. Gels in Microscale Electrophoresis. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2023; 16:161-179. [PMID: 37314879 DOI: 10.1146/annurev-anchem-091522-080207] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Gel matrices are fundamental to electrophoresis analyses of biopolymers in microscale channels. Both capillary gel and microchannel gel electrophoresis systems have produced fundamental advances in the scientific community. These analytical techniques remain as foundational tools in bioanalytical chemistry and are indispensable in the field of biotherapeutics. This review summarizes the current state of gels in microscale channels and provides a brief description of electrophoretic transport in gels. In addition to the discussion of traditional polymers, several nontraditional gels are introduced. Advances in gel matrices highlighted include selective polymers modified to contain added functionality as well as thermally responsive gels formed through self-assembly. This review discusses cutting-edge applications to challenging areas of discovery in DNA, RNA, protein, and glycan analyses. Finally, emerging techniques that result in multifunctional assays for real-time biochemical processing in capillary and three-dimensional channels are identified.
Collapse
Affiliation(s)
- Lisa A Holland
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, West Virginia, USA;
| | - Laura D Casto-Boggess
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, West Virginia, USA;
| |
Collapse
|
6
|
Wei Y, Du Q, Wang Y, Gao P, Wang Z, Jiang Y. Two-dimensional cellulose acetate membrane-supported mesoporous silica nanosheets for efficient nanosize-based molecules separation. J Mol Liq 2022. [DOI: 10.1016/j.molliq.2022.119827] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
7
|
Bhimwal R, Rustandi RR, Payne A, Dawod M. Recent advances in capillary gel electrophoresis for the analysis of proteins. J Chromatogr A 2022; 1682:463453. [DOI: 10.1016/j.chroma.2022.463453] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Revised: 08/23/2022] [Accepted: 08/25/2022] [Indexed: 11/16/2022]
|
8
|
MA Y, HU Y, ZHENG L, CHEN L, ZHAO X, QU F. [Annual review of capillary electrophoresis technology in 2021]. Se Pu 2022; 40:591-599. [PMID: 35791597 PMCID: PMC9404112 DOI: 10.3724/sp.j.1123.2022.03040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2022] [Indexed: 11/25/2022] Open
Abstract
This paper provides an annual review of capillary electrophoresis (CE) technology in 2021. A total of 291 research papers related to CE technology published in 2021 were retrieved from the ISI Web of Science using the keywords, "capillary electrophoresis-mass spectrometry" "capillary isoelectric focusing" "micellar electrokinetic chromatography", or "capillary electrophoresis" (not "capillary electrochromatography" "microchip" and "capillary monolithic column"). In addition, nine research papers related to CE technology in Chinese journals were reviewed: Chinese Journal of Chromatography and Chinese Journal of Analytical Chemistry. This review focused on seven papers published in Coordination Chemistry Reviews, Angewandte Chemie-International Edition, Nature Protocols, TrAC-Trends in Analytical Chemistry, and Signal Transduction and Targeted Therapy with impact factors (IFs) greater than 10.0, as well as 42 papers reported in Analytical Chemistry, Analytica Chimica Acta, Talanta, and Food Chemistry with IFs between 5.0 and 10.0. This review also provides a comprehensive overview of representative CE works in Journal of Chromatography A and Electrophoresis with IFs<5.0, as well as important Chinese journals, Chinese Journal of Chromatography and Chinese Journal of Analytical Chemistry. According to the IF, this paper introduces the representative work of CE-related papers to allow readers to quickly understand the important research progress of CE technology in the past year.
Collapse
Affiliation(s)
| | | | | | | | | | - Feng QU
- *Tel:(010)68918015,E-mail:(屈锋)
| |
Collapse
|
9
|
Feng R, Wu Y, Wang W, Fang Y, Chen M, Xia Y. Investigation of polymer−surfactant complexes by both micellar solubilization and pre-column derivatization capillary electrophoresis. J Mol Liq 2022. [DOI: 10.1016/j.molliq.2022.118898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
10
|
Štěpánová S, Kašička V. Applications of capillary electromigration methods for separation and analysis of proteins (2017–mid 2021) – A review. Anal Chim Acta 2022; 1209:339447. [DOI: 10.1016/j.aca.2022.339447] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2021] [Revised: 01/04/2022] [Accepted: 01/04/2022] [Indexed: 12/11/2022]
|
11
|
Guttman A, Filep C, Karger BL. Fundamentals of Capillary Electrophoretic Migration and Separation of SDS Proteins in Borate Cross-Linked Dextran Gels. Anal Chem 2021; 93:9267-9276. [PMID: 34165952 DOI: 10.1021/acs.analchem.1c01636] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Recent progress in the development and production of new, innovative protein therapeutics require rapid and adjustable high-resolution bioseparation techniques. Sodium dodecyl sulfate capillary gel electrophoresis (SDS-CGE) using a borate (B) cross-linked dextran (D) separation matrix is widely employed today for rapid consistency analysis of therapeutic proteins in manufacturing and release testing. Transient borate cross-linking of the semirigid dextran polymer chains leads to a high-resolution separation gel for SDS-protein complexes. To understand the migration and separation basis of the D/B gel, the present work explores various gel formulations of dextran monomer (2, 5, 7.5, and 10%) and borate cross-linker (2 and 4%) concentrations. Ferguson plots were analyzed for a mixture of protein standards with molecular weights ranging from 20 to 225 kDa, and the resulting nonlinear concave curves pointed to nonclassical sieving behavior. While the 2% D/4% B gel resulted in the fastest analysis time, the 10% D/2% B gel was found to produce the greatest separation window, even higher than with the 10% D/4% B gel, due to a significant increase in the electroosmotic flow of the former composition in the direction opposite to SDS-protein complex migration. The study then focused on SDS-CGE separation of a therapeutic monoclonal antibody and its subunits. A combination of molecular weight and shape selectivity as well as, to a lesser extent, surface charge density differences (due to glycosylation on the heavy chain) influenced migration. Greater molecular weight selectivity occurred for the higher monomer concentration gels, while improved glycoselectivity was obtained using a more dilute gel, even as low as 2% D/2% B. This latter gel took advantage of the dextran-borate-glycoprotein complexation. The study revealed that by modulating the dextran (monomer) and borate (cross-linker) concentration ratios of the sieving matrix, one can optimize the separation for specific biopharmaceutical modalities with excellent column-to-column, run-to-run, and gel-to-gel migration time reproducibilities (<0.96% relative standard deviation (RSD)). The widely used 10% dextran/4% borate gel represents a good screening option, which can then be followed by a modified composition, optimized for a specific separation as necessary.
Collapse
Affiliation(s)
- András Guttman
- Csaba Horváth Memorial Laboratory of Bioseparation Sciences, Research Center for Molecular Medicine, Faculty of Medicine, Doctoral School of Molecular Medicine, University of Debrecen, 98 Nagyerdei krt, Debrecen H-4032, Hungary.,Translational Glycomics Group, Research Institute for Biomolecular and Chemical Engineering, University of Pannonia, 10 Egyetem u, Veszprem H-8200, Hungary
| | - Csenge Filep
- Csaba Horváth Memorial Laboratory of Bioseparation Sciences, Research Center for Molecular Medicine, Faculty of Medicine, Doctoral School of Molecular Medicine, University of Debrecen, 98 Nagyerdei krt, Debrecen H-4032, Hungary
| | - Barry L Karger
- Barnett Institute, Northeastern University, 360 Huntington Avenue, Boston, Massachusetts 02115, United States
| |
Collapse
|