1
|
Buzitis NW, Clowers BH. Development of a Modular, Open-Source, Reduced-Pressure, Drift Tube Ion Mobility Spectrometer. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024; 35:804-813. [PMID: 38512132 DOI: 10.1021/jasms.4c00057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/22/2024]
Abstract
Toward the goal of minimizing construction costs while maintaining high performance, a new, reduced-pressure, drift tube ion mobility system is coupled with an ion trap mass analyzer through a custom ion shuttle. The availability of reduced-pressure ion mobility systems remains limited due to comparatively expensive commercial options and limited shared design features in the open literature. This report details the complete design and benchmarking characteristics of a reduced-pressure ion mobility system. The system is constructed from FR4 PCB electrodes and encased in a PTFE vacuum enclosure with custom torque-tightened couplers to utilize standard KF40 bulkheads. The PTFE enclosure directly minimizes the overall system expenses, and the implementation of threaded brass inserts allows for facile attachments to the vacuum enclosure without damaging the thermoplastic housing. Front and rear ion funnels maximize ion transmission and help mitigate the effects of radial ion diffusion. A custom planar ion shuttle transports ions from the exit of the rear ion funnel into the ion optics of an ion trap mass analyzer. The planar ion shuttle can couple the IM system to any contemporary Thermo Scientific ion trap mass analyzer. Signal stability and ion intensity remain unchanging following the implementation of the planar ion shuttle when compared to the original stacked ring ion guide. The constructed IM system showed resolving powers up to 85 for various small molecules and proteins using the Fourier transform from a ∼1 m drift tube. Recorded mobilities derived from first principles agree with published literature results with an average error of 1.1% and an average error toward literature values using single field calibration of <1.3%.
Collapse
Affiliation(s)
- Nathan W Buzitis
- Department of Chemistry, Washington State University, Pullman, Washington 99164, United States
| | - Brian H Clowers
- Department of Chemistry, Washington State University, Pullman, Washington 99164, United States
| |
Collapse
|
2
|
Wang J, Chen H, Ling Y, Zhang C, Zhou H, Wang X, Ni K. Enhancing ion mobility spectrometry performance through a programmable ion swarm shaping method based on Bradbury-Nielsen gates. Talanta 2024; 269:125396. [PMID: 37979507 DOI: 10.1016/j.talanta.2023.125396] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Revised: 10/19/2023] [Accepted: 11/03/2023] [Indexed: 11/20/2023]
Abstract
The ion gate is a critical element in drift tube ion mobility spectrometry (IMS) as it directly influences the resolving power and sensitivity of the system. However, the conventional Bradbury-Nielsen gate (BNG) often leads to deformation of the ion swarm shape, resulting in reduced resolving power and significant discrimination effects. To address these limitations, we propose a novel method that incorporates a cutting phase following the gate opening. This approach effectively reduces trailing edge deformation, resulting in a maximum resolving power of over 100 and increased signal intensity. Additionally, this method maintains high resolving power even during longer gate opening times. Remarkably, this method not only significantly reduces the mobility discrimination effect but also enables the achievement of reverse discrimination by adjusting the duration of the cutting phase. Consequently, it demonstrates the potential to selectively amplify the peak height of target ions. Our method offers straightforward implementation across all IMS systems utilizing the BNG, thereby significantly improving system performance.
Collapse
Affiliation(s)
- Jiyao Wang
- Division of Advanced Manufacturing, Tsinghua Shenzhen International Graduate School, Shenzhen, 518055, China
| | - Hai Chen
- Division of Advanced Manufacturing, Tsinghua Shenzhen International Graduate School, Shenzhen, 518055, China
| | - Yiyuan Ling
- Division of Advanced Manufacturing, Tsinghua Shenzhen International Graduate School, Shenzhen, 518055, China
| | - Chong Zhang
- Division of Advanced Manufacturing, Tsinghua Shenzhen International Graduate School, Shenzhen, 518055, China
| | - Haobo Zhou
- Division of Advanced Manufacturing, Tsinghua Shenzhen International Graduate School, Shenzhen, 518055, China
| | - Xiaohao Wang
- Division of Advanced Manufacturing, Tsinghua Shenzhen International Graduate School, Shenzhen, 518055, China; State Key Laboratory of Precision Measure Technology and Instruments, Tsinghua University, Beijing, 100084, China
| | - Kai Ni
- Division of Advanced Manufacturing, Tsinghua Shenzhen International Graduate School, Shenzhen, 518055, China.
| |
Collapse
|
3
|
Kobelt T, Lippmann M, Wuttke J, Wessel H, Zimmermann S. Influence of ionization volume and sample gas flow rate on separation power in gas chromatography-ion mobility spectrometry. J Chromatogr A 2024; 1713:464506. [PMID: 37983986 DOI: 10.1016/j.chroma.2023.464506] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Revised: 10/11/2023] [Accepted: 11/10/2023] [Indexed: 11/22/2023]
Abstract
In this work, the influence of the sample gas flow rate and the ionization region volume of an ion mobility spectrometer (IMS) used as a detector in gas chromatography (GC) on GC-IMS peak shape has been investigated. Therefore, a drift tube IMS with a field-switching ion shutter, a defined ionization region volume and an ultra-violet radiation source was used. To identify the influence of the sample gas flow rate entering the ionization region (equals the GC carrier gas flow rate if no further make-up gas is used) and the ionization region volume on peak broadening and signal intensity, different sample volumes as they would elute from a GC were tested at a variety of sample gas flow rates at a given ionization region volume. The results clearly show that for low sample gas flow rates a depletion of sample molecules in the ionization region leads to a significant decrease in effective detector volume but also to reduced signal intensities. Therefore, for optimal performance of a GC-IMS, the optimal operating point of the GC should match the flow range, where the IMS provides the best compromise between signal-to-noise ratio and peak broadening.
Collapse
Affiliation(s)
- Tim Kobelt
- Department of Sensors and Measurement Technology, Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Appelstr. 9A, Hannover 30167, Germany.
| | - Martin Lippmann
- Department of Sensors and Measurement Technology, Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Appelstr. 9A, Hannover 30167, Germany
| | - Jannik Wuttke
- Department of Sensors and Measurement Technology, Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Appelstr. 9A, Hannover 30167, Germany
| | - Hanno Wessel
- Department of Sensors and Measurement Technology, Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Appelstr. 9A, Hannover 30167, Germany
| | - Stefan Zimmermann
- Department of Sensors and Measurement Technology, Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Appelstr. 9A, Hannover 30167, Germany
| |
Collapse
|
4
|
Thoben C, Schlottmann F, Kobelt T, Nitschke A, Gloeden GL, Naylor CN, Kirk AT, Zimmermann S. Ultra-Fast Ion Mobility Spectrometer for High-Throughput Chromatography. Anal Chem 2023; 95:17073-17081. [PMID: 37953497 PMCID: PMC10666085 DOI: 10.1021/acs.analchem.3c03935] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Revised: 10/26/2023] [Accepted: 10/30/2023] [Indexed: 11/14/2023]
Abstract
Fast chromatography systems especially developed for high sample throughput applications require sensitive detectors with a high repetition rate. These high throughput techniques, including various chip-based microfluidic designs, often benefit from detectors providing subsequent separation in another dimension, such as mass spectrometry or ion mobility spectrometry (IMS), giving additional information about the analytes or monitoring reaction kinetics. However, subsequent separation is required at a high repetition rate. Here, we therefore present an ultra-fast drift tube IMS operating at ambient pressure. Short drift times while maintaining high resolving power are reached by several key instrumental design features: short length of the drift tube, resistor network of the drift tube, tristate ion shutter, and improved data acquisition electronics. With these design improvements, even slow ions with a reduced mobility of just 0.94 cm2/(V s) have a drift time below 1.6 ms. Such short drift times allow for a significantly increased repetition rate of 600 Hz compared with previously reported values. To further reduce drift times and thus increase the repetition rate, helium can be used as the drift gas, which allows repetition rates of up to 2 kHz. Finally, these significant improvements enable IMS to be used as a detector following ultra-fast separation including chip-based chromatographic systems or droplet microfluidic applications requiring high repetition rates.
Collapse
Affiliation(s)
- Christian Thoben
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Florian Schlottmann
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Tim Kobelt
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Alexander Nitschke
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Gian-Luca Gloeden
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Cameron N. Naylor
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Ansgar T. Kirk
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Stefan Zimmermann
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| |
Collapse
|
5
|
Zhang W, Cai J, Gao W, Han R, Wang H, Wu Y, Wu J, Wu Y, Wang C, Tang K, Yu J. Overlapping peak separation algorithm for ion mobility spectra based on multistrategy JAYA. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2023; 37:e9603. [PMID: 37580846 DOI: 10.1002/rcm.9603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Revised: 06/30/2023] [Accepted: 07/02/2023] [Indexed: 08/16/2023]
Abstract
RATIONALE In the field of separation science, ion mobility spectrometry (IMS) plays an important role as an analytical tool. However, the lack of sufficient structural resolution is a common problem in qualitative and quantitative analysis using IMS. A method is needed to solve the problem of overlapping peaks caused by insufficient resolution. METHODS The method uses multiple strategies to more effectively use population information to balance exploration and exploitation capabilities, prevent local optimization, accurately resolve overlapping peaks, quickly obtain optimal spectral peak model coefficients, and accurately identify compounds. RESULTS Multistrategy JAYA algorithm's (MSJAYA) performance is compared with improved particle swarm optimization (IPSO), dynamic inertia weight particle swarm optimization (DIWPSO), and multiobjective dynamic teaching-learning-based optimization (MDTLBO). The analysis shows that MSJAYA's maximum separation error is within 0.6%, a level of accuracy not guaranteed by the other algorithms. In addition, the separation error fluctuates within a much smaller range, demonstrating MSJAYA's superior robustness. CONCLUSIONS Compared with other overlapping peak separation algorithms, MSJAYA is more applicable because no special parameters are used. The method allows fast deconvolution analysis of strong overlapping peaks with multiple components, which greatly improves the resolution of IMS.
Collapse
Affiliation(s)
- Weiyang Zhang
- Faculty of Electrical Engineering and Computer Sciences, Ningbo University, Ningbo, China
- Zhejiang Engineering Research Center of Advanced Mass Spectrometry and Clinical Application, Institute of Mass Spectrometry, Ningbo University, Ningbo, China
| | - Jing Cai
- Academic Affairs Department, Zhejiang Police College, Hangzhou, China
| | - Wenqing Gao
- Zhejiang Engineering Research Center of Advanced Mass Spectrometry and Clinical Application, Institute of Mass Spectrometry, Ningbo University, Ningbo, China
| | - Renlu Han
- Zhejiang Engineering Research Center of Advanced Mass Spectrometry and Clinical Application, Institute of Mass Spectrometry, Ningbo University, Ningbo, China
| | - Haixing Wang
- Key Laboratory of Drug Monitoring and Control of Zhejiang Province, National Anti-Drug Laboratory Zhejiang Regional Center, Hangzhou, China
| | - Yanfei Wu
- Key Laboratory of Drug Monitoring and Control of Zhejiang Province, National Anti-Drug Laboratory Zhejiang Regional Center, Hangzhou, China
| | - Jiawei Wu
- Key Laboratory of Drug Monitoring and Control of Zhejiang Province, National Anti-Drug Laboratory Zhejiang Regional Center, Hangzhou, China
| | - Yong Wu
- Zhejiang Engineering Research Center of Advanced Mass Spectrometry and Clinical Application, Institute of Mass Spectrometry, Ningbo University, Ningbo, China
| | - Chenlu Wang
- Zhejiang Engineering Research Center of Advanced Mass Spectrometry and Clinical Application, Institute of Mass Spectrometry, Ningbo University, Ningbo, China
| | - Keqi Tang
- Zhejiang Engineering Research Center of Advanced Mass Spectrometry and Clinical Application, Institute of Mass Spectrometry, Ningbo University, Ningbo, China
| | - Jiancheng Yu
- Faculty of Electrical Engineering and Computer Sciences, Ningbo University, Ningbo, China
- Zhejiang Engineering Research Center of Advanced Mass Spectrometry and Clinical Application, Institute of Mass Spectrometry, Ningbo University, Ningbo, China
| |
Collapse
|
6
|
Raju CM, Buchowiecki K, Urban PL. An economical setup for atmospheric pressure chemical ionization drift tube ion-mobility mass spectrometry. Anal Chim Acta 2023; 1268:341359. [PMID: 37268338 DOI: 10.1016/j.aca.2023.341359] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 05/07/2023] [Accepted: 05/10/2023] [Indexed: 06/04/2023]
Abstract
Ion-mobility (IM) separations-performed in conjunction with mass spectrometry (MS)-increase selectivity of MS analyses. However, IM-MS instruments are costly, and many laboratories are only equipped with standard MS instruments without an IM separation stage. Therefore, it is appealing to upgrade the existing mass spectrometers with low-cost IM separation devices. Such devices can be constructed using widely available materials such as printed-circuit boards (PCBs). We demonstrate coupling of an economical PCB-based IM spectrometer (disclosed previously) with a commercial triple quadrupole (QQQ) mass spectrometer. The presented PCB-IM-QQQ-MS system incorporates an atmospheric pressure chemical ionization (APCI) source, drift tube comprising desolvation and drift regions, ion gates, and transfer line to the mass spectrometer. The ion gating is accomplished with the aid of two floated pulsers. The separated ions are divided into packets, which are sequentially introduced to the mass spectrometer. Volatile organic compounds (VOCs) are transferred with the aid of nitrogen gas flow from the sample chamber to the APCI source. The operation of the system has been demonstrated using standard compounds. The limits of detection for 2,4-lutidine, (-)-nicotine, and pyridine are 2.02 × 10-7 M, 1.54 × 10-9 mol, and 4.79 × 10-10 mol, respectively. The system was also used to monitor VOCs emitted from the porcine skin after exposure to nicotine patches, and VOCs released from meat undergoing the spoilage process. We believe this simple APCI-PCB-IM-QQQ-MS platform can be reproduced by others to augment the capabilities of the existing MS instrumentation.
Collapse
Affiliation(s)
- Chamarthi Maheswar Raju
- Department of Chemistry, National Tsing Hua University, 101, Section 2, Kuang-Fu Rd., Hsinchu, 300044, Taiwan
| | - Krzysztof Buchowiecki
- Department of Chemistry, National Tsing Hua University, 101, Section 2, Kuang-Fu Rd., Hsinchu, 300044, Taiwan
| | - Pawel L Urban
- Department of Chemistry, National Tsing Hua University, 101, Section 2, Kuang-Fu Rd., Hsinchu, 300044, Taiwan; Frontier Research Center on Fundamental and Applied Sciences of Matters, National Tsing Hua University, 101, Section 2, Kuang-Fu Rd., Hsinchu, 300044, Taiwan.
| |
Collapse
|
7
|
Boillat MA, Rakus JM, Hauser PC. Electrospray Ion Mobility Spectrometer Based on Flexible Printed-Circuit Board Electrodes with Improved Resolving Power. Anal Chem 2023. [PMID: 37407429 DOI: 10.1021/acs.analchem.3c01898] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/07/2023]
Abstract
An easily built drift tube instrument with ring electrodes made of rolled-up flexible printed circuit boards is reported. Its resolving power was maximized by careful attention to the drift tube geometry and the response time of the detector amplifier and by employing a high separation field strength. The separation of singly charged aliphatic quaternary ammonium ions introduced by electrospray was performed, and the measured resolving power was between 86 and 97% of the theoretical limit for three different drift tube lengths investigated. For the longest drift length of 30 cm, a resolving power of up to 228 was obtained. Three benzalkonium chlorides were also separated with resolving powers of over 210. The tristate injection scheme can also be used, with only a small loss of the separation performance compared to the two-state injection.
Collapse
Affiliation(s)
- Marc-Aurèle Boillat
- Department of Chemistry, University of Basel, Klingelbergstrasse 80, 4056 Basel, Switzerland
| | - Julian M Rakus
- Department of Chemistry, University of Basel, Klingelbergstrasse 80, 4056 Basel, Switzerland
| | - Peter C Hauser
- Department of Chemistry, University of Basel, Klingelbergstrasse 80, 4056 Basel, Switzerland
| |
Collapse
|
8
|
Thoben C, Raddatz CR, Tataroglu A, Kobelt T, Zimmermann S. How to Improve the Resolving Power of Compact Electrospray Ionization Ion Mobility Spectrometers. Anal Chem 2023; 95:8277-8283. [PMID: 37192335 DOI: 10.1021/acs.analchem.3c00471] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Every drift tube ion mobility spectrometer (IMS) has an optimum drift voltage to reach maximum resolving power. This optimum depends, among other things, on the temporal and spatial width of the injected ion packet and the pressure within the IMS. A reduction of the spatial width of the injected ion packet leads to improved resolving power, higher peak amplitudes when operating the IMS at optimum resolving power, and thus a better signal-to-noise ratio despite the reduced number of injected ions. Hereby, the performance of electrospray ionization (ESI)-IMS can be considerably improved. By setting the ion shutter opening time to just 5 μs and slightly increasing the pressure, a high resolving power RP > 150 can be achieved with a given drift length of just 75 mm. At such high resolving power, even a mixture of the herbicides isoproturon and chlortoluron having similar ion mobility can be well separated despite short drift length.
Collapse
Affiliation(s)
- Christian Thoben
- Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Christian-Robert Raddatz
- Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Aykut Tataroglu
- Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Tim Kobelt
- Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Stefan Zimmermann
- Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| |
Collapse
|
9
|
Schlottmann F, Schaefer C, Kirk AT, Bohnhorst A, Zimmermann S. A High Kinetic Energy Ion Mobility Spectrometer for Operation at Higher Pressures of up to 60 mbar. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023; 34:893-904. [PMID: 36999893 PMCID: PMC10161227 DOI: 10.1021/jasms.2c00365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) are usually operated at absolute pressures around 20 mbar in order to reach high reduced electric field strengths of up to 120 Td for influencing reaction kinetics in the reaction region. Such operating points significantly increase the linear range and limit chemical cross sensitivities. Furthermore, HiKE-IMS enables ionization of compounds normally not detectable in ambient pressure IMS, such as benzene, due to additional reaction pathways and fewer clustering reactions. However, operation at higher pressures promises increased sensitivity and smaller instrument size. In this work, we therefore study the theoretical requirements to prevent dielectric breakdown while maintaining high reduced electric field strengths at higher pressures. Furthermore, we experimentally investigate influences of the pressure, discharge currents and applied voltages on the corona ionization source. Based on these results, we present a HiKE-IMS that operates at a pressure of 60 mbar and reduced electric field strengths of up to 105 Td. The corona experiments show shark fin shaped curves for the total charge at the detector with a distinct optimum operating point in the glow discharge region at a corona discharge current of 5 μA. Here, the available charge is maximized while the generation of less-reactive ion species like NOx+ is minimized. With these settings, the reactant ion population, H3O+ and O2+, for ionizing and detecting nonpolar substances like n-hexane is still available even at 60 mbar, achieving a limit of detection of just 5 ppbV for n-hexane.
Collapse
Affiliation(s)
- Florian Schlottmann
- Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Appelstr. 9a, 30167 Hannover, Germany
| | - Christoph Schaefer
- Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Appelstr. 9a, 30167 Hannover, Germany
| | - Ansgar T Kirk
- Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Appelstr. 9a, 30167 Hannover, Germany
| | - Alexander Bohnhorst
- Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Appelstr. 9a, 30167 Hannover, Germany
| | - Stefan Zimmermann
- Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Appelstr. 9a, 30167 Hannover, Germany
| |
Collapse
|
10
|
Bohnhorst A, Zygmanowski A, Yin Y, Kirk AT, Zimmermann S. Highly Efficient Ion Manipulator for Tandem Ion Mobility Spectrometry: Exploring a Versatile Technique by a Study of Primary Alcohols. Anal Chem 2023; 95:7158-7169. [PMID: 37094083 PMCID: PMC10173250 DOI: 10.1021/acs.analchem.2c05483] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/26/2023]
Abstract
In this work, we present a tandem ion mobility spectrometer (IMS) utilizing a highly efficient ion manipulator allowing to store, manipulate, and analyze ions under high electric field strengths and controlled ion-neutral reactions at ambient conditions. The arrangement of tandem drift regions and an ion manipulator in a single drift tube allows a sequence of mobility selection of precursor ions, followed by storage and analysis, mobility separation, and detection of the resulting product ions. In this article, we present a journey exploring the capabilities of the present instrument by a study of eight different primary alcohols characterized at reduced electric field strengths E/N of up to 120 Td with a water vapor concentration ranging from 40 to 540 ppb. Under these conditions, protonated alcohol monomers up to a carbon number of nine could be dissociated, resulting in 18 different fragmented product ions in total. The fragmentation patterns revealed regularities, which can be used for assignment to the chemical class and improved classification of unknown substances. Furthermore, both the time spent in high electrical field strengths and the reaction time with water vapor can be tuned precisely, allowing the fragment distribution to be influenced. Thus, further information regarding the relations of the product ions can be gathered in a standalone drift tube IMS for the first time.
Collapse
Affiliation(s)
- Alexander Bohnhorst
- Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, Hannover 30167, Germany
- ACKISION GmbH, Appelstr. 9A, Hannover 30167, Germany
| | - Anne Zygmanowski
- Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, Hannover 30167, Germany
| | - Yu Yin
- Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, Hannover 30167, Germany
| | - Ansgar T Kirk
- Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, Hannover 30167, Germany
- ACKISION GmbH, Appelstr. 9A, Hannover 30167, Germany
| | - Stefan Zimmermann
- Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, Hannover 30167, Germany
| |
Collapse
|
11
|
Hitzemann M, Schaefer C, Kirk AT, Nitschke A, Lippmann M, Zimmermann S. Easy to assemble dielectric barrier discharge plasma ionization source based on printed circuit boards. Anal Chim Acta 2023; 1239:340649. [PMID: 36628746 DOI: 10.1016/j.aca.2022.340649] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2022] [Revised: 11/14/2022] [Accepted: 11/20/2022] [Indexed: 11/29/2022]
Abstract
Here, we present a new and an easy to assemble dielectric barrier discharge plasma ionization source based on printed circuit boards with two parallel isolated electrodes for generating a plasma inside an inert fused silica capillary. For demonstration, this plasma source is coupled to an ion mobility spectrometer. With two different sample gas feeds the analytes can either pass through the plasma or bypass the plasma before entering the reaction region of the ion mobility spectrometer, allowing for different ionization pathways, e.g. electron impact ionization, ionization by excited species, e.g. helium metastables, or chemical ionization via reactant ions generated inside or downstream of the plasma. The plasma source, in particular, the electrode geometry and the capillary diameter were designed with the help of electric field simulations. A rectangular electrode with a height of at least twice the outer diameter of the capillary turned out to be ideal, in both the simulation and the experiment. Furthermore, a simple control electronics has been developed, which can be easily applied to other plasma sources. With the plasma source presented here, detection limits in the mid pptv range have been reached.
Collapse
Affiliation(s)
- Moritz Hitzemann
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Appelstr. 9A, 30167, Hannover, Germany.
| | - Christoph Schaefer
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Appelstr. 9A, 30167, Hannover, Germany
| | - Ansgar T Kirk
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Appelstr. 9A, 30167, Hannover, Germany
| | - Alexander Nitschke
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Appelstr. 9A, 30167, Hannover, Germany
| | - Martin Lippmann
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Appelstr. 9A, 30167, Hannover, Germany
| | - Stefan Zimmermann
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Appelstr. 9A, 30167, Hannover, Germany
| |
Collapse
|
12
|
Butalewicz JP, Sanders JD, Clowers BH, Brodbelt JS. Improving Ion Mobility Mass Spectrometry of Proteins through Tristate Gating and Optimization of Multiplexing Parameters. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023; 34:101-108. [PMID: 36469482 DOI: 10.1021/jasms.2c00274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Coupling drift tube ion mobility (IM) to Fourier transform mass spectrometry (FT-MS) affords the opportunity for gas-phase separation of ions based on size and conformation with high-resolution mass analysis. However, combining IM and FT-MS is challenging because ions exit the drift tube on a much faster time scale than the rate of mass analysis. Fourier transform (FT) and Hadamard transform multiplexing methods have been implemented to overcome the duty-cycle mismatch, offering new avenues for obtaining high-resolution, high-mass-accuracy analysis of mobility-selected ions. The gating methods used to integrate the drift tube with the FT mass analyzer discriminate against the transmission of large, low-mobility ions owing to the well-known gate depletion effect. Tristate gating strategies have been shown to increase ion transmission for drift tube IM-FT-MS systems through implementation of dual ion gating, controlling the quantity and timing of ions through the drift tube to reduce losses of slow-moving ions. Here we present an optimized set of multiplexing parameters for tristate gating ion mobility of several proteins on an Orbitrap mass spectrometer and further report parameters for increased ion transmission and mobility resolution as well as decreased experimental times from 15 min down to 30 s. On average, peak intensities in the arrival time distributions (ATDs) for ubiquitin increased 2.1× on average, while those of myoglobin increased by 1.5× with a resolving power increase on average of 11%.
Collapse
Affiliation(s)
- Jamie P Butalewicz
- Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, United States
| | - James D Sanders
- Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Brian H Clowers
- Department of Chemistry, Washington State University, Pullman, Washington 99164, United States
| | - Jennifer S Brodbelt
- Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, United States
| |
Collapse
|
13
|
Alhajji E, Boulghobra A, Bonose M, Berthias F, Moussa F, Maître P. Multianalytical Approach for Deciphering the Specific MS/MS Transition and Overcoming the Challenge of the Separation of a Transient Intermediate, Quinonoid Dihydrobiopterin. Anal Chem 2022; 94:12578-12585. [PMID: 36074025 DOI: 10.1021/acs.analchem.2c00924] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Despite recent technological developments in analytical chemistry, separation and direct characterization of transient intermediates remain an analytical challenge. Among these, separation and direct characterization of quinonoid dihydrobiopterin (qH2Bip), a transient intermediate of tetrahydrobiopterin (H4Bip)-dependent hydroxylation reactions, essential in living organisms, with important and varied human pathophysiological impacts, are a clear illustration. H4Bip regeneration may be impaired by competitive nonenzymatic autoxidation reactions, such as isomerization of qH2Bip into a more stable 7,8-H2Bip (H2Bip) isomer, and subsequent nonenzymatic oxidation reactions. The quinonoid qH2Bip intermediate thus plays a key role in H4Bip-dependent hydroxylation reactions. However, only a few experimental results have indirectly confirmed this finding while revealing the difficulty of isolating qH2Bip from H4Bip-containing solutions. As a result, no current H4Bip assay method allows this isomer to be quantified even by liquid chromatography-tandem mass spectrometry (MS/MS). Here, we report isolation, structural characterization, and abundance of qH2Bip formed upon H4Bip autoxidation using three methods integrated into MS/MS. First, we characterized the structure of the two observed H2B isomers using IR photodissociation spectroscopy in conjunction with quantum chemical calculations. Then, we used differential ion mobility spectrometry to fully separate all oxidized forms of H4Bip including qH2Bip. These data are consistent and show that qH2Bip can also be unambiguously identified thanks to its specific MS/MS transition. This finding paves the way for the quantification of qH2Bip with MS/MS methods. Most importantly, the half-life value of this intermediate is nearly equivalent to that of H4Bip (tens of minutes), suggesting that an accurate method of H4Bip analysis should include the quantification of qH2Bip.
Collapse
Affiliation(s)
- Eskander Alhajji
- Institut de Chimie Physique, CNRS UMR 8000, Université Paris-Saclay, 91405 Orsay Cedex, France
| | - Ayoub Boulghobra
- Institut de Chimie Physique, CNRS UMR 8000, Université Paris-Saclay, 91405 Orsay Cedex, France
| | - Myriam Bonose
- Institut de Chimie Physique, CNRS UMR 8000, Université Paris-Saclay, 91405 Orsay Cedex, France
| | - Francis Berthias
- Institut de Chimie Physique, CNRS UMR 8000, Université Paris-Saclay, 91405 Orsay Cedex, France
| | - Fathi Moussa
- Institut de Chimie Physique, CNRS UMR 8000, Université Paris-Saclay, 91405 Orsay Cedex, France
| | - Philippe Maître
- Institut de Chimie Physique, CNRS UMR 8000, Université Paris-Saclay, 91405 Orsay Cedex, France
| |
Collapse
|
14
|
Chantipmanee N, Boillat MA, Hauser PC. High voltage pulser for ion shutters in ion mobility spectrometry based on an optocoupler. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2022; 93:074703. [PMID: 35922285 DOI: 10.1063/5.0093479] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Accepted: 06/14/2022] [Indexed: 06/15/2023]
Abstract
A novel high voltage pulser for an ion shutter used in drift-tube ion-mobility spectrometers is described. The simple design suitable for the in-house construction of these spectrometers relies on a special optocoupler to isolate the triggering circuitry from the high voltage at the ion shutter. The device was tested with an electrospray-ionization ion-mobility device with a 10 cm drift tube operated at 4 kV into which a standard test mixture of four tetraalkylamines was injected with a negative going gating pulse of about 50 V on top of 4 kV. A fall time of 15.7 µs and a rise time of 2.0 µs were determined for the pulse, which was adequate for the required injection pulse width of 450 µs. Resolving powers between 61 and 81 were determined for the four quaternary amines, which were found to be comparable to the performance obtained with a previously reported pulser circuitry of a different design used as a reference.
Collapse
Affiliation(s)
- Nattapong Chantipmanee
- University of Basel, Department of Chemistry, Klingelbergstrasse 80, 4056 Basel, Switzerland
| | - Marc-Aurèle Boillat
- University of Basel, Department of Chemistry, Klingelbergstrasse 80, 4056 Basel, Switzerland
| | - Peter C Hauser
- University of Basel, Department of Chemistry, Klingelbergstrasse 80, 4056 Basel, Switzerland
| |
Collapse
|
15
|
te Brinke E, Arrizabalaga-Larrañaga A, Blokland MH. Insights of ion mobility spectrometry and its application on food safety and authenticity: A review. Anal Chim Acta 2022; 1222:340039. [DOI: 10.1016/j.aca.2022.340039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2022] [Revised: 06/01/2022] [Accepted: 06/03/2022] [Indexed: 11/01/2022]
|
16
|
Wireless Low-Power Transfer for Galvanically Isolated High-Voltage Applications. ELECTRONICS 2022. [DOI: 10.3390/electronics11060923] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
For various applications, such as gate drivers for transistors, wireless chargers for mobile devices and cars, and isolated measurement equipment, an isolated DC power supply for electronic components is required. In this work, a new concept for an isolated power supply with insulation strength of 50 kV and power transmission of up to 60 W to supply measurement equipment with 12 or 24 V is presented. Furthermore, high overall efficiency of 82.5% at 55 W is achieved. Feasibility is demonstrated in a real application powering data acquisition electronics at high reference potential. Our new concept uses a coreless printed circuit board (PCB) transformer (15 cm × 10 cm × 4 cm and a weight of 480 g) designed for maximum efficiency via a coil layout and close proximity of adjacent coils on one PCB while reaching high isolation strength via the PCB material and potted coils. To increase efficiency, we investigated different coil geometries at different frequencies. A low-cost design consisting of two Qi charging coils mounted on one PCB is compared with our integrated PCB transformers manufactured from a four-layer PCB with ferrites applied on the outside. With this new design, high isolation voltages are possible while reaching high transformer efficiency of up to 90%.
Collapse
|
17
|
Hitzemann M, Kirk AT, Lippmann M, Bohnhorst A, Zimmermann S. Miniaturized Drift Tube Ion Mobility Spectrometer with Ultra-Fast Polarity Switching. Anal Chem 2022; 94:777-786. [DOI: 10.1021/acs.analchem.1c03268] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Moritz Hitzemann
- Department of Sensors and Measurement Technology, Institute of Electrical Engineering and Measurement Technology, Leibniz Universität Hannover, 30167 Hannover, Germany
| | - Ansgar T. Kirk
- Department of Sensors and Measurement Technology, Institute of Electrical Engineering and Measurement Technology, Leibniz Universität Hannover, 30167 Hannover, Germany
| | - Martin Lippmann
- Department of Sensors and Measurement Technology, Institute of Electrical Engineering and Measurement Technology, Leibniz Universität Hannover, 30167 Hannover, Germany
| | - Alexander Bohnhorst
- Department of Sensors and Measurement Technology, Institute of Electrical Engineering and Measurement Technology, Leibniz Universität Hannover, 30167 Hannover, Germany
| | - Stefan Zimmermann
- Department of Sensors and Measurement Technology, Institute of Electrical Engineering and Measurement Technology, Leibniz Universität Hannover, 30167 Hannover, Germany
| |
Collapse
|
18
|
Thoben C, Raddatz CR, Lippmann M, Salehimoghaddam Z, Zimmermann S. Electrospray ionization ion mobility spectrometer with new tristate ion gating for improved sensitivity for compounds with lower ion mobility. Talanta 2021; 233:122579. [PMID: 34215071 DOI: 10.1016/j.talanta.2021.122579] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Revised: 05/27/2021] [Accepted: 05/28/2021] [Indexed: 11/25/2022]
Abstract
An electrospray is a dispersed nebula of charged droplets produced under the influence of a strong electric field. The charged droplets subsequently result in ions in the gas phase. Therefore, electrospray is a commonly used method for transferring liquids to the gas phase while ionizing its constituents at the same time. In this work, we investigate the performance of an electrospray ionization ion mobility spectrometer by varying the electric field strength in the desolvation region. In particular, we investigate a new tristate ion shutter with increased sensitivity for ions with higher molecular mass and lower ion mobility that are usually suppressed by classical Bradbury-Nielsen or Tyndall-Powell ion shutters when using short gating times as required for high resolving power. The electric field in the tristate ion shutter affects the optimal ratio of the electric field strengths in the drift and desolvation region. Furthermore, the solvent flow rate needs to be considered when setting the field strengths in the desolvation region. However, a higher electric field strength in the desolvation region affects the field at the emitter tip. For this reason, a smaller ratio of the drift field strength and the desolvation field strength is beneficial, especially since higher solvent flow rates require higher fields to initiate an electrospray. In this work, we use tetraoctylammonium bromide as an instrument standard and the fungicide metalaxyl, the herbicide isoproturon and the antibiotic cefuroxime as model compounds.
Collapse
Affiliation(s)
- C Thoben
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Appelstr. 9A, 30167, Hannover, Germany.
| | - C-R Raddatz
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Appelstr. 9A, 30167, Hannover, Germany
| | - M Lippmann
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Appelstr. 9A, 30167, Hannover, Germany
| | - Z Salehimoghaddam
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Appelstr. 9A, 30167, Hannover, Germany
| | - S Zimmermann
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Appelstr. 9A, 30167, Hannover, Germany
| |
Collapse
|