1
|
Naylor CN, Nagy G. Recent advances in high-resolution traveling wave-based ion mobility separations coupled to mass spectrometry. MASS SPECTROMETRY REVIEWS 2024. [PMID: 39087820 DOI: 10.1002/mas.21902] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2024] [Revised: 06/07/2024] [Accepted: 07/22/2024] [Indexed: 08/02/2024]
Abstract
Recently, ion mobility spectrometry-mass spectrometry (IMS-MS) has become more readily incorporated into various omics-based workflows. These growing applications are due to developments in instrumentation within the last decade that have enabled higher-resolution ion mobility separations. Two such platforms are the cyclic (cIMS) and structures for lossless ion manipulations (SLIM), both of which use traveling wave ion mobility spectrometry (TWIMS). High-resolution separations achieved with these techniques stem from the drastically increased pathlengths, on the order of 10 s of meters to >1 km, in both cIMS-MS and SLIM IMS-MS, respectively. Herein, we highlight recent developments and advances, for the period 2019-2023, in high-resolution traveling wave-based IMS-MS through instrumentation, calibration strategies, hyphenated techniques, and applications. Specifically, we will discuss applications including CCS calculations in multipass IMS-MS separations, coupling of IMS-MS with chromatography, imaging, and cryogenic infrared spectroscopy, and isomeric separations of glycans, lipids, and other small metabolites.
Collapse
Affiliation(s)
- Cameron N Naylor
- Department of Chemistry, University of Utah, Salt Lake City, Utah, USA
| | - Gabe Nagy
- Department of Chemistry, University of Utah, Salt Lake City, Utah, USA
| |
Collapse
|
2
|
Haack A, Schaefer C, Zimmermann S. On the Arrival Time Distribution of Reacting Systems in Ion Mobility Spectrometry. Anal Chem 2024; 96. [PMID: 39009503 PMCID: PMC11295131 DOI: 10.1021/acs.analchem.4c02010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2024] [Revised: 06/13/2024] [Accepted: 07/09/2024] [Indexed: 07/17/2024]
Abstract
Ion mobility spectrometry (IMS) is a widely used gas-phase separation technique, particularly when coupled with mass spectrometry (MS). Modern IMS instruments often apply elevated reduced field strengths for improved ion separation and ion focusing. These alter the collision dynamics and further drive ion reaction processes that can change the analyte's structure. As a result, the measured arrival time distribution (ATD) can change with the applied reduced field strengths. In this work, we systematically study how the ion collision dynamics and the ion reaction dynamics, as a function of the reduced field strength, can alter the ATD. To this end, we investigate 2,6-di-tert-butylpyridine, methanol, and ethyl acetate using a home-built drift tube IMS coupled to a home-built MS and extensive first-principles Monte Carlo modeling. We show how elevated reduced field strengths can actually lower resolving power through increased ion diffusion and how the field dependency of the ion mobility can introduce uncertainties to collision cross sections (CCS) calculated from the measured mobilities. On top of the collision dynamics, we show how chemical transformation processes that alter the analyte's CCS, e.g., dynamic clustering or fragmentation, can lead to broadened, shifted, or non-Gaussian ATDs and how sensitive these processes are to the applied field strengths. We highlight how first-principles ion dynamics simulations can help to understand and even harness the mentioned effects.
Collapse
Affiliation(s)
- Alexander Haack
- Department of Sensors and
Measurement Technology, Institute of Electrical Engineering and Measurement
Technology, Leibniz University Hannover, 30167 Hannover, Germany
| | - Christoph Schaefer
- Department of Sensors and
Measurement Technology, Institute of Electrical Engineering and Measurement
Technology, Leibniz University Hannover, 30167 Hannover, Germany
| | - Stefan Zimmermann
- Department of Sensors and
Measurement Technology, Institute of Electrical Engineering and Measurement
Technology, Leibniz University Hannover, 30167 Hannover, Germany
| |
Collapse
|
3
|
Kingsley S, Hoover M, Pettit-Bacovin T, Sawyer AR, Chouinard CD. SLIM-Based High-Resolution Ion Mobility Reveals New Structural Insights into Isomeric Vitamin D Metabolites and their Isotopologues. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024. [PMID: 38709652 DOI: 10.1021/jasms.4c00116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2024]
Abstract
Testing for vitamin D deficiency remains a high-volume clinical assay, much of which is done using mass spectrometry-based methods to alleviate challenges in selectivity associated with immunoassays. Ion mobility-mass spectrometry (IM-MS) has been proposed as a rapid alternative to traditional LC-MS/MS methods, but understanding the structural ensemble that contributes to the ion mobility behavior of this molecular class is critical. Herein we demonstrate the first application of high-resolution Structures for Lossless Ion Manipulations (SLIM) IM separations of several groups of isomeric vitamin D metabolites. Despite previous IM studies of these molecules, the high resolving power of SLIM (Rp ∼ 200) has revealed additional conformations for several of the compounds. The highly similar collision cross sections (CCS), some differing by as little as 0.7%, precluded adequate characterization with low-resolution IM techniques where, in some cases, wider than expected peak widths and/or subtle shoulders may have hinted at their presence. Importantly, these newly resolved peaks often provided a unique mobility that could be used to separate isomers and provides potential for their use in quantification. Lastly, the contribution of isotopic labeling to arrival time distribution for commonly used 13C- and deuterium-labeled internal standards was explored. Minor shifts of ∼0.2-0.3% were observed, and in some instances these shifts were specific to the conformer being measured (i.e., "closed" vs "open"). Accounting for these shifts is important during raw data extraction to ensure reproducible peak area integration, which will be a critical consideration in future quantitative applications.
Collapse
Affiliation(s)
- Selena Kingsley
- Clemson University, Department of Chemistry; Clemson, South Carolina 29634, United States
- Lake Superior State University, Department of Chemistry, Sault Sainte Marie, Michigan 49783, United States
| | - Makenna Hoover
- Clemson University, Department of Chemistry; Clemson, South Carolina 29634, United States
| | - Terra Pettit-Bacovin
- Clemson University, Department of Chemistry; Clemson, South Carolina 29634, United States
| | - Anna Rose Sawyer
- Clemson University, Department of Chemistry; Clemson, South Carolina 29634, United States
| | | |
Collapse
|
4
|
Nagy G. High-resolution ion mobility separations coupled to mass spectrometry: What's next? JOURNAL OF MASS SPECTROMETRY : JMS 2024; 59:e5014. [PMID: 38605463 DOI: 10.1002/jms.5014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Revised: 02/01/2024] [Accepted: 02/21/2024] [Indexed: 04/13/2024]
Abstract
Herein, I provide a personal perspective on high-resolution multipass ion mobility spectrometry-mass spectrometry (IMS-MS), with a specific emphasis on cyclic (cIMS) and structures for lossless ion manipulations (SLIM IMS)-based separations. My overarching goal for this perspective was to detail what I believe will be the key important areas in which IMS-MS will help shape the bioanalytical community and especially omics-based research.
Collapse
Affiliation(s)
- Gabe Nagy
- Department of Chemistry, University of Utah, Salt Lake City, Utah, USA
| |
Collapse
|
5
|
Williamson DL, Windsor HM, Nagy G. Isolating the Contributions from Moments of Inertia in Isotopic Shifts Measured by High-Resolution Cyclic Ion Mobility Separations. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024. [PMID: 38654703 DOI: 10.1021/jasms.4c00082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/26/2024]
Abstract
The unexpected finding that isotopomers (i.e., isotopic isomers) can be separated with high-resolution ion mobility spectrometry-mass spectrometry (IMS-MS) has raised new structural considerations affecting an ion's mobility, namely its center of mass (CoM) and moments of inertia (MoI). Unfortunately, thus far, no studies have attempted to experimentally isolate either CoM or MoI, as they are intrinsically linked by their definitions, where MoI is calculated in relation to CoM. In this study, we designed and synthesized four isotopically labeled tetrapropylammonium (TAA3) ions, each with a unique mass distribution. Three of the synthesized TAA3 ions were labeled symmetrically, thus having identical CoM but differing MoI, which we verified using density functional theory (DFT) calculations. Consequently, we were able to isolate the effect of MoI changes in high-resolution IMS-MS separations. Cyclic ion mobility spectrometry-mass spectrometry (cIMS-MS) separations of the isotopically labeled TAA3 variants revealed isotopic mobility shifts attributable solely to changes in MoI. A 60-m cIMS-MS separation demonstrated that two nominally isobaric TAA3 pseudoisotopomers could be partially resolved, showcasing potential feasibility for isotopomer separations on commercially available IMS-MS platforms. With our previously established collision cross section (CCS) calibration protocol, we also quantified the relationship between MoI and CCS. Our results represent the first demonstration of IMS-MS separations based solely on MoI differences. We believe these findings will contribute important evidence to the growing body of literature on the physical nature of isotopic shifts in IMS-MS separations and work toward more accurate CCS predictions.
Collapse
Affiliation(s)
- David L Williamson
- Department of Chemistry, University of Utah, 315 South 1400 East, Room 2020, Salt Lake City, Utah 84112, United States
| | - Haisley M Windsor
- Department of Chemistry, University of Utah, 315 South 1400 East, Room 2020, Salt Lake City, Utah 84112, United States
| | - Gabe Nagy
- Department of Chemistry, University of Utah, 315 South 1400 East, Room 2020, Salt Lake City, Utah 84112, United States
| |
Collapse
|
6
|
Mubas-Sirah F, Gandhi VD, Latif M, Hua L, Tootchi A, Larriba-Andaluz C. Ion mobility calculations of flexible all-atom systems at arbitrary fields using two-temperature theory. Phys Chem Chem Phys 2024; 26:4118-4124. [PMID: 38226667 DOI: 10.1039/d3cp05415b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2024]
Abstract
Ion mobility spectrometry (IMS) separates and analyzes ions based on their mobility in a gas under an electric field. When the field is increased, the mobility varies in a complex way that depends on the relative velocity between gas and ion, their electrostatic potential interactions, and the effects from direct impingement. Recently, the two-temperature theory, primarily developed for monoatomic ions in monoatomic gases, has been extended to study mobilities at arbitrary fields using polyatomic ions in polyatomic gases, with some success. However, this extension poses challenges, such as inelastic collisions between gas and ion and structural modifications of ions as they heat up. These challenges become significant when working with diatomic gases and flexible molecules. In a previous study, experimental mobilities of tetraalkylammonium salts were obtained using a FAIMS instrument, showing satisfactory agreement with numerical two-temperature theory predictions. However, deviations occurred at fields greater than 100 Td. To address this issue, this paper introduces a modified high-field calculation method that accounts for the structural changes in ions due to field heating. The study focuses on tetraheptylammonium (THA+), tetradecylammonium (TDA+), and tetradodecylammonium (TDDA+) salts. Molecular structures were generated at various temperatures using MM2 forcefield. The mobility was calculated using IMoS 1.13 with two-temperature trajectory method calculations up to the fourth approximation. Multiple effective temperatures were considered, and a linear weighing system was used to create mobility vs. reduced field strength plots. The results suggest that the structural enlargement due to ion heating plays a significant role in mobility at high fields, aligning better with experimental data. FAIMS' dispersion plots also show improved agreement with experimental results. However, the contribution of inelastic collisions and energy transfer to rotational degrees of freedom in gas molecules remains a complex and challenging aspect.
Collapse
Affiliation(s)
- Farah Mubas-Sirah
- Department of Mechanical Engineering, Indiana University - Purdue University Indianapolis, Indianapolis, IN, USA.
| | - Viraj D Gandhi
- Department of Mechanical Engineering, Indiana University - Purdue University Indianapolis, Indianapolis, IN, USA.
- Department of Mechanical Engineering, Purdue University, West Lafayette, IN, USA
| | - Mohsen Latif
- Department of Mechanical Engineering, Indiana University - Purdue University Indianapolis, Indianapolis, IN, USA.
| | - Leyan Hua
- Department of Mechanical Engineering, Indiana University - Purdue University Indianapolis, Indianapolis, IN, USA.
| | - Amirreza Tootchi
- Department of Mechanical Engineering, Indiana University - Purdue University Indianapolis, Indianapolis, IN, USA.
| | - Carlos Larriba-Andaluz
- Department of Mechanical Engineering, Indiana University - Purdue University Indianapolis, Indianapolis, IN, USA.
| |
Collapse
|
7
|
Ribeiro FWM, Omari I, Thomas GT, Paul M, Williams PJH, McIndoe JS, Correra TC. Microstructural Analysis of Benzoxazine Cationic Ring-Opening Polymerization Pathways. Macromol Rapid Commun 2024; 45:e2300470. [PMID: 37716013 DOI: 10.1002/marc.202300470] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Revised: 09/06/2023] [Indexed: 09/18/2023]
Abstract
Herein, an evaluation of the initial step of benzoxazine polymerization is presented by mass spectrometry, with a focus on differentiating the phenoxy and phenolic products formed by distinct pathways of the cationic ring opening polymerization (ROP) mechanism of polybenzoxazine formation. The use of infrared multiple photon dissociation (IRMPD) and ion mobility spectrometry (IMS) techniques allows for differentiation of the two pathways and provides valuable insights into the ROP mechanism. The results suggest that type I pathway is favored in the initial stages of the reaction yielding the phenoxy product, while type II product should be observed at later stages when the phenoxy product would interconvert to the most stable type II phenolic product. Overall, the findings presented here provide important information on the initial step of the benzoxazine polymerization, allowing the development of optimal polymerization conditions and represents a way to evaluate other multifunctional polymerization processes.
Collapse
Affiliation(s)
- Francisco W M Ribeiro
- Department of Fundamental Chemistry, Institute of Chemistry, University of São Paulo, Av. Prof. Lineu Prestes, 748, Cidade Universitária, São Paulo, SP, 05508-000, Brazil
| | - Isaac Omari
- Department of Chemistry, University of Victoria, P. O. Box 3065, Victoria, BC V8W 3V6, Canada
| | - Gilian T Thomas
- Department of Chemistry, University of Victoria, P. O. Box 3065, Victoria, BC V8W 3V6, Canada
| | - Mathias Paul
- Department of Chemistry, University of Victoria, P. O. Box 3065, Victoria, BC V8W 3V6, Canada
| | - Peter J H Williams
- Department of Chemistry, University of Victoria, P. O. Box 3065, Victoria, BC V8W 3V6, Canada
| | - J Scott McIndoe
- Department of Chemistry, University of Victoria, P. O. Box 3065, Victoria, BC V8W 3V6, Canada
| | - Thiago C Correra
- Department of Fundamental Chemistry, Institute of Chemistry, University of São Paulo, Av. Prof. Lineu Prestes, 748, Cidade Universitária, São Paulo, SP, 05508-000, Brazil
| |
Collapse
|
8
|
Williamson DL, Nagy G. Coupling Isotopic Shifts with Collision Cross-Section Measurements for Carbohydrate Characterization in High-Resolution Ion Mobility Separations. Anal Chem 2023; 95:13992-14000. [PMID: 37683280 PMCID: PMC10538943 DOI: 10.1021/acs.analchem.3c02619] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/10/2023]
Abstract
Herein, we introduce a two-dimensional strategy to better characterize carbohydrate isomers. In a single experiment, we can derive cyclic ion mobility-mass spectrometry (cIMS-MS)-based collision cross-section (CCS) values in conjunction with measuring isotopic shifts through the relative arrival times of light and heavy isotopologues. These isotopic shifts were introduced by permethylating carbohydrates with either light, CH3, or heavy, CD3, labels at every available hydroxyl group to generate a light/heavy pair of isotopologues for every individual species analyzed. We observed that our calculated CCS values, which were exclusively measured for the light isotopologues, were orthogonal to our measured isotopic shifts (i.e., relative arrival time values between heavy and light permethylated isotopologues). Our permethylation-induced isotopic shifts scaled well with increasing molecular weight, up to ∼m/z 1300, expanding the analysis of isotopic shifts to molecules 3-4 times as large as those previously studied. Our presented use of coupling CCS values with the measurement of isotopic shifts in a single cIMS-MS experiment is a proof-of-concept demonstration that our two-dimensional approach can improve the characterization of challenging isomeric carbohydrates. We envision that our presented 2D approach will have broad utility for varying molecular classes as well as being amenable to many forms of derivatization.
Collapse
Affiliation(s)
- David L Williamson
- Department of Chemistry, University of Utah, 315 South 1400 East, Room 2020, Salt Lake City, Utah 84112, United States
| | - Gabe Nagy
- Department of Chemistry, University of Utah, 315 South 1400 East, Room 2020, Salt Lake City, Utah 84112, United States
| |
Collapse
|
9
|
Harrilal CP, Garimella SVB, Chun J, Devanathan N, Zheng X, Ibrahim YM, Larriba-Andaluz C, Schenter G, Smith RD. The Role of Ion Rotation in Ion Mobility: Ultrahigh-Precision Prediction of Ion Mobility Dependence on Ion Mass Distribution and Translational to Rotational Energy Transfer. J Phys Chem A 2023. [PMID: 37330993 DOI: 10.1021/acs.jpca.3c01264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/20/2023]
Abstract
The role of ion rotation in determining ion mobilities is explored using the subtle gas phase ion mobility shifts based on differences in ion mass distributions between isotopomer ions that have been observed with ion mobility spectrometry (IMS) measurements. These mobility shifts become apparent for IMS resolving powers on the order of ∼1500 where relative mobilities (or alternatively momentum transfer collision cross sections; Ω) can be measured with a precision of ∼10 ppm. The isotopomer ions have identical structures and masses, differing only in their internal mass distributions, and their Ω differences cannot be predicted by widely used computational approaches, which ignore the dependence of Ω on the ion's rotational properties. Here, we investigate the rotational dependence of Ω, which includes changes to its collision frequency due to thermal rotation as well as the coupling of translational to rotational energy transfer. We show that differences in rotational energy transfer during ion-molecule collisions provide the major contribution to isotopomer ion separations, with only a minor contribution due to an increase in collision frequency due to ion rotation. Modeling including these factors allowed for differences in Ω to be calculated that precisely mirror the experimental separations. These findings also highlight the promise of pairing high-resolution IMS measurements with theory and computation for improved elucidation of subtle structural differences between ions.
Collapse
Affiliation(s)
- Christopher P Harrilal
- Biological Sciences Division, Pacific Northwest National Laboratory, 902 Battelle Blvd, Richland, Washington 99354, United States
| | - Sandilya V B Garimella
- Biological Sciences Division, Pacific Northwest National Laboratory, 902 Battelle Blvd, Richland, Washington 99354, United States
| | - Jaehun Chun
- Physical and Computational Sciences Directorate, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| | - Nikhil Devanathan
- Biological Sciences Division, Pacific Northwest National Laboratory, 902 Battelle Blvd, Richland, Washington 99354, United States
| | - Xueyun Zheng
- Biological Sciences Division, Pacific Northwest National Laboratory, 902 Battelle Blvd, Richland, Washington 99354, United States
| | - Yehia M Ibrahim
- Biological Sciences Division, Pacific Northwest National Laboratory, 902 Battelle Blvd, Richland, Washington 99354, United States
| | - Carlos Larriba-Andaluz
- Department of Mechanical and Energy Engineering, IUPUI, Indianapolis, Indiana 46202, United States
| | - Gregory Schenter
- Physical and Computational Sciences Directorate, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| | - Richard D Smith
- Biological Sciences Division, Pacific Northwest National Laboratory, 902 Battelle Blvd, Richland, Washington 99354, United States
| |
Collapse
|
10
|
Pathak P, Shvartsburg AA. High-Definition Differential Ion Mobility Spectrometry with Structural Isotopic Shifts for Anionic Compounds. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023. [PMID: 37319378 DOI: 10.1021/jasms.3c00190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Differential ion mobility spectrometry (FAIMS) had emerged in the 2000s as a novel tool for postionization separations in conjunction with mass spectrometry (MS). High-definition FAIMS introduced a decade ago has enabled resolution of peptide, lipid, and other molecular isomers with minute structural variations and recently the isotopic shift analyses where the spectral pattern for stable isotopes fingerprints the ion geometry. Those studies, including all isotopic shift analyses, were in the positive mode. Here, we achieve the same high resolution for anions exemplified by phthalic acid isomers. The resolving power and magnitude of isotopic shifts are in line with the metrics for analogous haloaniline cations, establishing high-definition negative-mode FAIMS with structurally specific isotopic shifts. Different shifts (including the new 18O) remain additive and mutually orthogonal, demonstrating the generality of those properties across the elements and charge states. Expanding to common (not halogenated) organic compounds is a key step toward the broad use of FAIMS isotopic shift methodology.
Collapse
Affiliation(s)
- Pratima Pathak
- Department of Chemistry and Biochemistry, Wichita State University, 1845 Fairmount, Wichita, Kansas 67260, United States
| | - Alexandre A Shvartsburg
- Department of Chemistry and Biochemistry, Wichita State University, 1845 Fairmount, Wichita, Kansas 67260, United States
| |
Collapse
|
11
|
Gandhi VD, Lee J, Hua L, Latif M, Hogan CJ, Larriba-Andaluz C. Investigation of Zero-/High-Field Ion Mobility Orthogonal Separation Using a Hyphenated DMA-FAIMS System and Validation of the Two-Temperature Theory at Arbitrary Field for Tetraalkylammonium Salts in Nitrogen. Anal Chem 2023; 95:7941-7949. [PMID: 37172072 DOI: 10.1021/acs.analchem.3c00509] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Toward greater separation techniques for ions, a differential mobility analyzer (DMA) has been coupled with field asymmetric waveform ion mobility spectrometry (FAIMS) to take advantage of two mobility-related but different methods of separation. The filtering effect of the DMA allows ions to be selected individually based on low-field mobility and studied in FAIMS at variable electric field, yielding mobility separations in two dimensions. Because spectra fully describe ion mobility at variable field strength, results are then compared with a two-temperature theory-predicted mobility up to the fourth-order approximation. The comparison yields excellent results up to at least 100 Td, beyond which the theory deviates from experiments. This is attributed to two effects, the enlargement of the structure due to ion heating and the inelasticity of the collisions with the nitrogen bath gas. The corrected mobility can then be used to predict the dispersion plot through a newly developed implicit equation that circumvents the possible issues related to the more elaborate Buryakov equation. Our results simultaneously show that the DMA-FAIMS coupling yields complete information on ion mobility versus the field-strength to gas-density ratio and works toward predicting such spectra from ion structures and gas properties.
Collapse
Affiliation(s)
- Viraj D Gandhi
- Department of Mechanical Engineering, Purdue University, 585 Purdue Mall, West Lafayette, Indiana 47907, United States
- Department of Mechanical and Energy Engineering, IUPUI, 723 W. Michigan St., Indianapolis, Indiana 46202, United States
| | - Jihyeon Lee
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, Minnesota 55455, United States
| | - Leyan Hua
- Department of Mechanical and Energy Engineering, IUPUI, 723 W. Michigan St., Indianapolis, Indiana 46202, United States
| | - Mohsen Latif
- Department of Mechanical and Energy Engineering, IUPUI, 723 W. Michigan St., Indianapolis, Indiana 46202, United States
| | - Christopher J Hogan
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, Minnesota 55455, United States
| | - Carlos Larriba-Andaluz
- Department of Mechanical and Energy Engineering, IUPUI, 723 W. Michigan St., Indianapolis, Indiana 46202, United States
| |
Collapse
|
12
|
Williamson DL, Trimble TK, Nagy G. Hydrogen-Deuterium-Exchange-Based Mass Distribution Shifts in High-Resolution Cyclic Ion Mobility Separations. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023. [PMID: 37098274 DOI: 10.1021/jasms.3c00008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
The mass distribution of ions influences separations in ion mobility spectrometry-mass spectrometry (IMS-MS). Herein, we introduce a method to induce mass distribution shifts for various analytes using hydrogen-deuterium exchange (HDX) immediately prior to ionization using a dual syringe approach. By replacing labile hydrogens on analytes with deuteriums, we were able to differentiate isomers using separations of isotopologues. For each analyte studied, every possible level of deuteration (from undeuterated to fully deuterated) was generated and then separated using cyclic ion mobility spectrometry-mass spectrometry (cIMS-MS). The information gained from such separations (relative arrival times; tRel. values) was found to be orthogonal to conventional IMS-MS separations. Additionally, the observed shifts were linearly additive with increasing deuteration, suggesting that this methodology could be extended to analytes with a larger number of labile hydrogens. For one isomer pair, as few as two deuteriums were able to produce a large enough mass distribution shift to differentiate isomers. In another experiment, we found that the mass distribution shift was large enough to overcome the reduced mass contribution, resulting in a "flipped" arrival time where the heavier deuterated isotopologue arrived before the lighter one. In this work, we present a proof-of-concept demonstration that mass-distribution-based shifts, tRel. values, could potentially act as an added dimension to characterize molecules in IMS-MS. We anticipate, along with future work in this area, that mass-distribution-based shifts could enable the identification of unknown molecules through a database-driven approach in an analogous fashion to collision cross section (CCS) measurements.
Collapse
Affiliation(s)
- David L Williamson
- Department of Chemistry, University of Utah, 315 South 1400 East, Room 2020, Salt Lake City, Utah 84112, United States
| | - Tyson K Trimble
- Department of Chemistry, University of Utah, 315 South 1400 East, Room 2020, Salt Lake City, Utah 84112, United States
| | - Gabe Nagy
- Department of Chemistry, University of Utah, 315 South 1400 East, Room 2020, Salt Lake City, Utah 84112, United States
| |
Collapse
|
13
|
Pathak P, Shvartsburg AA. High-Definition Ion Mobility/Mass Spectrometry with Structural Isotopic Shifts for Nominally Isobaric Isotopologues. J Phys Chem A 2023; 127:3914-3923. [PMID: 37083428 DOI: 10.1021/acs.jpca.3c01792] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/22/2023]
Abstract
We had reported the isotopic envelopes in differential IMS (FAIMS) separations depending on the ion structure. However, this new approach to distinguish isomers was constrained by the unit-mass resolution commingling all nominally isobaric isotopologues. Here, we directly couple high-definition FAIMS to ultrahigh-resolution (Orbitrap) MS and employ the resulting platform to explore the FAIMS spectra for isotopic fine structure. The peak shifts therein for isotopologues of halogenated anilines with 15N and 13C (split by 6 mDa) in N2/CO2 buffers dramatically differ, more than for the 13C, 37Cl, or 81Br species apart by 1 or 2 Da. The shifts in FAIMS space upon different elemental isotopic substitutions are orthogonal mutually and to the underlying separations, forming fingerprint multidimensional matrices and 3-D trajectories across gas compositions that redundantly delineate all isomers considered. The interlocking instrumental and methodological upgrades in this work take the structural isotopic shift approach to the next level.
Collapse
Affiliation(s)
- Pratima Pathak
- Department of Chemistry and Biochemistry, Wichita State University, 1845 Fairmount, Wichita, Kansas 67260, United States
| | - Alexandre A Shvartsburg
- Department of Chemistry and Biochemistry, Wichita State University, 1845 Fairmount, Wichita, Kansas 67260, United States
| |
Collapse
|
14
|
Fu D, Habtegabir SG, Wang H, Feng S, Han Y. Understanding of protomers/deprotomers by combining mass spectrometry and computation. Anal Bioanal Chem 2023:10.1007/s00216-023-04574-1. [PMID: 36737499 DOI: 10.1007/s00216-023-04574-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 01/19/2023] [Accepted: 01/27/2023] [Indexed: 02/05/2023]
Abstract
Multifunctional compounds may form different prototropic isomers under different conditions, which are known as protomers/deprotomers. In biological systems, these protomer/deprotomer isomers affect the interaction modes and conformational landscape between compounds and enzymes and thus present different biological activities. Study on protomers/deprotomers is essentially the study on the acidity/basicity of each intramolecular functional group and its effect on molecular structure. In recent years, the combination of mass spectrometry (MS) and computational chemistry has been proven to be a powerful and effective means to study prototropic isomers. MS-based technologies are developed to discriminate and characterize protomers/deprotomers to provide structural information and monitor transformations, showing great superiority than other experimental methods. Computational chemistry is used to predict the thermodynamic stability of protomers/deprotomers, provide the simulated MS/MS spectra, infrared spectra, and calculate collision cross-section values. By comparing the theoretical data with the corresponding experimental results, the researchers can not only determine the protomer/deprotomer structure, but also investigate the structure-activity relationship in a given system. This review covers various MS methods and theoretical calculations and their devotion to isomer discrimination, structure identification, conformational transformation, and phase transition investigation of protomers/deprotomers.
Collapse
Affiliation(s)
- Dali Fu
- State Key Laboratory of Heavy Oil Processing, College of Chemical Engineering and Environment, China University of Petroleum-Beijing, Beijing, 102249, People's Republic of China
| | - Sara Girmay Habtegabir
- State Key Laboratory of Heavy Oil Processing, College of Chemical Engineering and Environment, China University of Petroleum-Beijing, Beijing, 102249, People's Republic of China
| | - Haodong Wang
- State Key Laboratory of Heavy Oil Processing, College of Chemical Engineering and Environment, China University of Petroleum-Beijing, Beijing, 102249, People's Republic of China
| | - Shijie Feng
- State Key Laboratory of Heavy Oil Processing, College of Chemical Engineering and Environment, China University of Petroleum-Beijing, Beijing, 102249, People's Republic of China
| | - Yehua Han
- State Key Laboratory of Heavy Oil Processing, College of Chemical Engineering and Environment, China University of Petroleum-Beijing, Beijing, 102249, People's Republic of China.
| |
Collapse
|
15
|
Gandhi VD, Hua L, Chen X, Latif M, Larriba-Andaluz C. A Critical Review of the two-temperature theory and the derivation of matrix elements. High field Ion mobility and energy calculation for all-atom structures in light gases using a 12-6-4 potential. TALANTA OPEN 2023. [DOI: 10.1016/j.talo.2023.100191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2023] Open
|
16
|
Williamson DL, Nagy G. Isomer and Conformer-Specific Mass Distribution-Based Isotopic Shifts in High-Resolution Cyclic Ion Mobility Separations. Anal Chem 2022; 94:12890-12898. [PMID: 36067027 DOI: 10.1021/acs.analchem.2c02991] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Herein, we present the use of mass distribution-based isotopic shifts in high-resolution cyclic ion mobility spectrometry-mass spectrometry (cIMS-MS)-based separations to characterize various isomeric species as well as conformers. Specifically, by using the observed relative arrival time values for the isotopologues found in the isotopic envelope after long pathlength cIMS-MS separations, we were able to distinguish dibromoaniline, dichloroaniline, and quaternary ammonium salt isomers, as well as a pair of 25-hydroxyvitamin D3 conformers based on their respective mass distribution-based shifts. Our observed shifts were highly reproducible and broadly applied to the isotopologues of various atoms (i.e., Cl, Br, and C). Additionally, through a control experiment, we determined that such shifts are indeed pathlength-independent, thus demonstrating that our presented methodology could be readily extended to other high-resolution IMS-MS platforms. These results are the first characterization of conformers using mass distribution-based IMS-MS shifts, as well as the first use of a commercial cIMS-MS platform to characterize isomers via their mass distribution-based shifts. We anticipate that our methodology will have broad applicability for biological analytes and that mass distribution-based shifts could potentially act as an added dimension of analysis in existing IMS-MS workflows in omics-based research. Specifically, we envision that the development of a database of these mass distribution-based shifts could, for example, enable the identification of unknown metabolites in complex matrices.
Collapse
Affiliation(s)
- David L Williamson
- Department of Chemistry, University of Utah, 315 South 1400 East, Room 2020, Salt Lake City, Utah 84112, United States
| | - Gabe Nagy
- Department of Chemistry, University of Utah, 315 South 1400 East, Room 2020, Salt Lake City, Utah 84112, United States
| |
Collapse
|
17
|
Williamson D, Nagy G. Evaluating the Utility of Temporal Compression in High-Resolution Traveling Wave-Based Cyclic Ion Mobility Separations. ACS MEASUREMENT SCIENCE AU 2022; 2:361-369. [PMID: 36785568 PMCID: PMC9836067 DOI: 10.1021/acsmeasuresciau.2c00016] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Ion mobility spectrometry coupled to mass spectrometry (IMS-MS) is slowly becoming a more integral part in omics-based workflows. With the recent technological advancements in IMS-MS instrumentation, particularly those involving traveling wave-based separations, ultralong pathlengths have become readily available in commercial platforms (e.g., Select Series Cyclic IMS from Waters Corporation and MOBIE from MOBILion). However, a tradeoff exists in such ultralong pathlength separations: increasing peak-to-peak resolution at the cost of lower signal intensities and thus poorer sensitivity of measurements. Herein, we explore the utility of temporal compression, where ions are compressed in the time domain, following high-resolution cyclic ion mobility spectrometry-mass spectrometry-based separations on a commercially available, unmodified platform. We assessed temporal compression in the context of various separations including those of reverse sequence peptide isomers, chiral noncovalent complexes, and isotopologues. From our results, we demonstrated that temporal compression improves IMS peak intensities by up to a factor of 4 while only losing ∼5 to 10% of peak-to-peak resolution. Additionally, the improvement in peak quality and signal-to-noise ratio was evident when comparing IMS-MS separations with and without a temporal compression step performed. Temporal compression can readily be implemented in existing traveling wave-based IMS-MS platforms, and our initial proof-of-concept demonstration shows its promise as a tool for improving peak shapes and peak intensities without sacrificing losses in resolution.
Collapse
|
18
|
Williamson DL, Bergman AE, Heider EC, Nagy G. Experimental Measurements of Relative Mobility Shifts Resulting from Isotopic Substitutions with High-Resolution Cyclic Ion Mobility Separations. Anal Chem 2022; 94:2988-2995. [PMID: 35107996 DOI: 10.1021/acs.analchem.1c05240] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Herein, we report on the experimental measurements for estimated relative mobility shifts caused by changes in mass distribution from isotopic substitutions in isotopologues and isotopomers with high-resolution cyclic ion mobility separations. By utilizing unlabeled and fully labeled isotopologues with the same isotopic substitutions (i.e., 2H or 13C), we created a highly precise mobility scale for each set analyzed to determine the magnitude of such mass distribution shifts and thus calculate estimated deviations from expected, theoretical reduced mass contributions. We observed relative mobility shifts in various isotopologues (e.g., hexadecyltrimethylammonium, sucrose, and palmitic acid species) that deviated from reduced mass theory, according to the Mason-Schamp relationship, ranging in estimated magnitude from ∼0.007% up to ∼0.1% in relative mobility. More interestingly, it was found that two deuterated palmitic acid isotopomers also differed by ∼0.03% from one another in their respective relative mobility shifts. Our results are the first report of isotopologue and isotopomer separations on a commercially available cyclic ion mobility spectrometry-mass spectrometry platform. We envision that our presented mobility scale methodology will have broad applicability in studying the effect of mass distribution changes from isotopic substitutions in other biomolecules and help pave the way for the improvement of ion mobility theory and collision cross section calculators.
Collapse
Affiliation(s)
- David L Williamson
- Department of Chemistry, University of Utah, 315 South 1400 East, Room 2020, Salt Lake City, Utah 84112, United States
| | - Addison E Bergman
- Department of Chemistry, University of Utah, 315 South 1400 East, Room 2020, Salt Lake City, Utah 84112, United States
| | - Emily C Heider
- Department of Chemistry, Utah Valley University, 800 W University Parkway, PS-009G, Orem, Utah 84058, United States
| | - Gabe Nagy
- Department of Chemistry, University of Utah, 315 South 1400 East, Room 2020, Salt Lake City, Utah 84112, United States
| |
Collapse
|