1
|
Zhao L, Wang L, Huang J, Chen H, Liu L, Shi M, Zhang M. Label-Free Imaging of Mesenchymal Stem Cell Spheroid Differentiation with Flexible-Probe SECM and a Microfluidic Device. Anal Chem 2024; 96:13473-13481. [PMID: 39122667 DOI: 10.1021/acs.analchem.4c01637] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/12/2024]
Abstract
Mesenchymal stem cells (MSCs) have emerged as an indispensable source for stem cell research and preclinical studies due to their capacity for in vitro proliferation and their potential to differentiate into mesodermal lineages, particularly into osteoblasts. This capability has propelled their application in the fields of bone regeneration and osteochondral repair. Traditional methodologies for assessing the differentiation status of MSCs necessitate invasive procedures such as cell lysis or fixation. In this study, we introduce a nondestructive technique that utilizes an integrated label-free approach to evaluate the osteogenic maturation of MSC spheroid aggregates. This method employs scanning electrochemical microscopy (SECM) with a flexible probe in conjunction with a top-removable microfluidic device designed for easy SECM access. By tracking the production rate of p-aminophenol (PAP) in the generation/collection mode and assessing morphological changes via the negative feedback mode using [Ru(NH3)6]Cl3 (Ruhex), we can discern variations in the alkaline phosphatase (ALP) activity indicative of osteogenic differentiation. This innovative strategy enables the direct evaluation of osteogenic differentiation in MSC spheroids cultured within microwell arrays without necessitating any labeling procedures. The utilization of a flexible microelectrode as the probe that scans in contact mode (with probe-substrate distances potentially as minimal as 0 μm) affords enhanced resolution compared to the traditional stiff-probe technique. Furthermore, this method is compatible with subsequent molecular biology assays, including gene expression analysis and immunofluorescence, thereby confirming the electrochemical findings and establishing the validity of this integrative approach.
Collapse
Affiliation(s)
- Liang Zhao
- Center of Excellence for Environmental Safety and Biological Effects, College of Chemistry and Life Science, Department of Chemistry, Beijing University of Technology, 100 Pingleyuan, Beijing 100124, China
- Beijing Key Laboratory for Bioengineering and Sensing Technology, School of Chemistry and Biological Engineering, University of Science and Technology Beijing, 30 Xueyuan Road, Beijing 100083, China
| | - Lin Wang
- Beijing Key Laboratory for Bioengineering and Sensing Technology, School of Chemistry and Biological Engineering, University of Science and Technology Beijing, 30 Xueyuan Road, Beijing 100083, China
| | - Jing Huang
- Beijing Key Laboratory for Bioengineering and Sensing Technology, School of Chemistry and Biological Engineering, University of Science and Technology Beijing, 30 Xueyuan Road, Beijing 100083, China
| | - Hongyu Chen
- Beijing Key Laboratory for Bioengineering and Sensing Technology, School of Chemistry and Biological Engineering, University of Science and Technology Beijing, 30 Xueyuan Road, Beijing 100083, China
| | - Lu Liu
- Beijing Key Laboratory for Bioengineering and Sensing Technology, School of Chemistry and Biological Engineering, University of Science and Technology Beijing, 30 Xueyuan Road, Beijing 100083, China
| | - Mi Shi
- Beijing Key Laboratory for Bioengineering and Sensing Technology, School of Chemistry and Biological Engineering, University of Science and Technology Beijing, 30 Xueyuan Road, Beijing 100083, China
| | - Meiqin Zhang
- Beijing Key Laboratory for Bioengineering and Sensing Technology, School of Chemistry and Biological Engineering, University of Science and Technology Beijing, 30 Xueyuan Road, Beijing 100083, China
| |
Collapse
|
2
|
Poderyte M, Ramanavicius A, Valiūnienė A. Exploring the Living Cell: Applications and Advances of Scanning Electrochemical Microscopy. Crit Rev Anal Chem 2024:1-12. [PMID: 38557222 DOI: 10.1080/10408347.2024.2328135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
Abstract
A living cell is a complex network of molecular, biochemical and physiological processes. Cellular activities, such as ion transport, metabolic processes, and cell-cell interactions can be determined electrochemically by detecting the electrons or ions exchanged in these processes. Electrochemical methods often are noninvasive, and they can enable the real-time monitoring of cellular processes. Scanning electrochemical microscopy (SECM) is an advanced scanning probe electroanalysis technique that can map the surface topography and local reactivity of a substrate with high precision at the micro- or nanoscale. By measuring electrochemical signals, such as redox reactions, ion fluxes, and pH changes, SECM can provide valuable insights into cellular activity. As a result of its compatibility with liquid medium measurements and its nondestructive nature, SECM has gained popularity in living cell research. This review aims to furnish an overview of SECM, elucidating its principles, applications, and its potential to contribute significantly to advancements in cell biology, electroporation, and biosensors. As a multidisciplinary tool, SECM is distinguished by its ability to unravel the intricacies of living cells and offers promising avenues for breakthroughs in our understanding of cellular complexity.
Collapse
Affiliation(s)
- Margarita Poderyte
- Faculty of Chemistry and Geosciences, Institute of Chemistry, Vilnius University, Vilnius, Lithuania
| | - Arunas Ramanavicius
- Faculty of Chemistry and Geosciences, Institute of Chemistry, Vilnius University, Vilnius, Lithuania
- Laboratory of Nanotechnology, State Research Institute Centre of Physical Sciences and Technology, Vilnius, Lithuania
| | - Aušra Valiūnienė
- Faculty of Chemistry and Geosciences, Institute of Chemistry, Vilnius University, Vilnius, Lithuania
- State Research Institute Center for Physical Sciences and Technology, Vilnius, Lithuania
| |
Collapse
|
3
|
Santana Santos C, Jaato BN, Sanjuán I, Schuhmann W, Andronescu C. Operando Scanning Electrochemical Probe Microscopy during Electrocatalysis. Chem Rev 2023; 123:4972-5019. [PMID: 36972701 PMCID: PMC10168669 DOI: 10.1021/acs.chemrev.2c00766] [Citation(s) in RCA: 26] [Impact Index Per Article: 26.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/29/2023]
Abstract
Scanning electrochemical probe microscopy (SEPM) techniques can disclose the local electrochemical reactivity of interfaces in single-entity and sub-entity studies. Operando SEPM measurements consist of using a SEPM tip to investigate the performance of electrocatalysts, while the reactivity of the interface is simultaneously modulated. This powerful combination can correlate electrochemical activity with changes in surface properties, e.g., topography and structure, as well as provide insight into reaction mechanisms. The focus of this review is to reveal the recent progress in local SEPM measurements of the catalytic activity of a surface toward the reduction and evolution of O2 and H2 and electrochemical conversion of CO2. The capabilities of SEPMs are showcased, and the possibility of coupling other techniques to SEPMs is presented. Emphasis is given to scanning electrochemical microscopy (SECM), scanning ion conductance microscopy (SICM), electrochemical scanning tunneling microscopy (EC-STM), and scanning electrochemical cell microscopy (SECCM).
Collapse
Affiliation(s)
- Carla Santana Santos
- Analytical Chemistry - Center for Electrochemical Sciences (CES), Faculty of Chemistry and Biochemistry, Ruhr University Bochum, Universitätsstr. 150, D-44780 Bochum, Germany
| | - Bright Nsolebna Jaato
- Technical Chemistry III, Center for Nanointegration Duisburg-Essen (CENIDE), University of Duisburg-Essen Carl-Benz-Straße 199, 47057 Duisburg, Germany
| | - Ignacio Sanjuán
- Technical Chemistry III, Center for Nanointegration Duisburg-Essen (CENIDE), University of Duisburg-Essen Carl-Benz-Straße 199, 47057 Duisburg, Germany
| | - Wolfgang Schuhmann
- Analytical Chemistry - Center for Electrochemical Sciences (CES), Faculty of Chemistry and Biochemistry, Ruhr University Bochum, Universitätsstr. 150, D-44780 Bochum, Germany
| | - Corina Andronescu
- Technical Chemistry III, Center for Nanointegration Duisburg-Essen (CENIDE), University of Duisburg-Essen Carl-Benz-Straße 199, 47057 Duisburg, Germany
| |
Collapse
|
4
|
Chen H, Kong X, Wang D, Zhang M. Flexible Disk Ultramicroelectrode for High-Resolution and Substrate-Tolerable Scanning Electrochemical Microscopy Imaging. Anal Chem 2022; 94:17320-17327. [PMID: 36448925 DOI: 10.1021/acs.analchem.2c04465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022]
Abstract
A simple and universal strategy for fabricating flexible 25 μm platinum (Pt) disk ultramicroelectrodes (UMEs) was proposed, where a pulled borosilicate glass micropipette acted as a mold for shaping the flexible tip with flexible epoxy resin. The whole preparation procedure was highly efficient, enabling 10 or more probes to be manually fabricated within 10 h. Intriguingly, this technique permits an adjustable RG ratio, tip length, and stiffness, which could be tuned according to varying experimental demands. Besides, the electroactive area of the probe could be exposed and made renewable with a thin blade, allowing its reuse in multiple experiments. The flexibility characterization was then employed to optimize the resin/hardener mass ratio of epoxy resin and the tip position during HF etching in the fabrication process, suggesting that more hardener, a larger RG value, or a longer tip length obtained stronger deformation resistance. Subsequently, the as-prepared probe was examined by optical microscopy, cyclic voltammetry, and SECM approach curves. The results demonstrated the probe possessed good geometry with a small RG ratio of less than 3 and exceptional electrochemical properties, and its insulating sheath remained undeformed after blade cutting. Owing to the tip's flexibility, it could be operated in contactless mode with an extremely low working distance and even in contact mode scanning to achieve high spatial resolution and high sensitivity while guaranteeing that the tip and samples would suffer minimal damage if the tip crashed. Finally, the flexible probe was successfully employed in three scanning scenarios where tilted and 3D structured PDMS microchips, a latent fingerprint deposited on the stiff copper sheet, and soft egg white were included. In all, the flexible probe encompasses the advantages of traditional disk UMEs and circumvents their principal drawbacks of tip crash and causing sample scratches, which is thus more compatible with large specimens of 3D structured, stiff, or even soft topography.
Collapse
Affiliation(s)
- Hongyu Chen
- Beijing Key Laboratory for Bioengineering and Sensing Technology, School of Chemistry and Biological Engineering, University of Science and Technology Beijing, 30 Xueyuan Road, Beijing100083, China
| | - Xiangyi Kong
- Beijing Key Laboratory for Bioengineering and Sensing Technology, School of Chemistry and Biological Engineering, University of Science and Technology Beijing, 30 Xueyuan Road, Beijing100083, China
| | - Dongrui Wang
- Beijing Key Laboratory for Bioengineering and Sensing Technology, School of Chemistry and Biological Engineering, University of Science and Technology Beijing, 30 Xueyuan Road, Beijing100083, China
| | - Meiqin Zhang
- Beijing Key Laboratory for Bioengineering and Sensing Technology, School of Chemistry and Biological Engineering, University of Science and Technology Beijing, 30 Xueyuan Road, Beijing100083, China
| |
Collapse
|
5
|
Liu Y, Fan Z, Qiao L, Liu B. Advances in microfluidic strategies for single-cell research. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116822] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
6
|
UTAGAWA Y, ITO K, INOUE KY, NASHIMOTO Y, INO K, SHIKU H. Electrochemical Substrates and Systems for Enzyme-Based Bioassays. BUNSEKI KAGAKU 2022. [DOI: 10.2116/bunsekikagaku.71.109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
| | - Kentaro ITO
- Graduate School of Environmental Studies, Tohoku University
| | - Kumi Y. INOUE
- Center for Basic Education, Faculty of Engineering, Graduate Faculty of Interdisciplinary Research, University of Yamanashi
| | - Yuji NASHIMOTO
- Frontier Research Institute for Interdisciplinary Sciences, Tohoku University
| | - Kosuke INO
- Graduate School of Engineering, Tohoku University
| | | |
Collapse
|
7
|
Hong T, Liu X, Zhou Q, Liu Y, Guo J, Zhou W, Tan S, Cai Z. What the Microscale Systems "See" In Biological Assemblies: Cells and Viruses? Anal Chem 2021; 94:59-74. [PMID: 34812604 DOI: 10.1021/acs.analchem.1c04244] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Tingting Hong
- School of Pharmacy, Changzhou University, Changzhou, Jiangsu 213164, China
| | - Xing Liu
- School of Pharmacy, Changzhou University, Changzhou, Jiangsu 213164, China
| | - Qi Zhou
- School of Pharmacy, Changzhou University, Changzhou, Jiangsu 213164, China
| | - Yilian Liu
- School of Pharmacy, Changzhou University, Changzhou, Jiangsu 213164, China
| | - Jing Guo
- School of Pharmacy, Changzhou University, Changzhou, Jiangsu 213164, China
| | - Wenhu Zhou
- Xiangya School of Pharmaceutical Sciences, Central South University, 172 Tongzipo Road, Changsha, Hunan 410013, China
| | - Songwen Tan
- Xiangya School of Pharmaceutical Sciences, Central South University, 172 Tongzipo Road, Changsha, Hunan 410013, China.,Jiangsu Dawning Pharmaceutical Co., Ltd., Changzhou, Jiangsu 213100, China
| | - Zhiqiang Cai
- School of Pharmacy, Changzhou University, Changzhou, Jiangsu 213164, China.,Jiangsu Dawning Pharmaceutical Co., Ltd., Changzhou, Jiangsu 213100, China
| |
Collapse
|