Nouwairi R, Jones CK, Charette ME, Holmquist E, Golabek Z, Landers JP. Automated Nanoliter Volume Assay Optimization on a Cost-Effective Microfluidic Disc. Anal Chem 2025; 97:300-311. [PMID: 39731577 PMCID: PMC11740179 DOI: 10.1021/acs.analchem.4c04210] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2024] [Revised: 11/14/2024] [Accepted: 12/16/2024] [Indexed: 12/30/2024]
Abstract
Optimizing multireagent assays often requires successive titration of individual components until the optimal combination of conditions is achieved. This process is time-consuming, laborious, and often expensive since parallelized experimentation requires bulk consumption of reagents. Microfluidics presents a solution through miniaturization of standard processes by reducing reaction volume, executing multiple parallel workflows, and enabling automation. While single-digit microliter reactions can be effective, scaling to nanoliter volumes without employing droplets is difficult. We describe a cost-effective, customizable centrifugal microdisc for optimizing assays pertinent to a broad array of applications. An automated two-stage metering process leverages tunable, laser-actuated valves that retain defined fluidic volumes upon opening and meter discrete nanoliter volumes into downstream architecture. We demonstrate that ∼150 nL volumes could be metered and tuned for specific applications. We illustrate the potential for controlled metering of up to four reagents with high parallelization for rapid, cost-effective assay optimization with minimal manual intervention.
Collapse
Affiliation(s)
- Renna
L. Nouwairi
- Department
of Chemistry, University of Virginia, Charlottesville, Virginia 22904, United States
| | - Carter K. Jones
- Department
of Chemistry, University of Virginia, Charlottesville, Virginia 22904, United States
| | - Maura E. Charette
- Department
of Chemistry, University of Virginia, Charlottesville, Virginia 22904, United States
| | - Emilee Holmquist
- Department
of Chemistry, University of Virginia, Charlottesville, Virginia 22904, United States
| | - Zoey Golabek
- Department
of Chemistry, University of Virginia, Charlottesville, Virginia 22904, United States
| | - James P. Landers
- Department
of Chemistry, University of Virginia, Charlottesville, Virginia 22904, United States
- Department
of Mechanical Engineering, University of
Virginia, Charlottesville, Virginia 22904, United States
- Department
of Pathology, University of Virginia, Charlottesville, Virginia 22904, United States
| |
Collapse
|
2
|
Kobelt T, Lippmann M, Nitschke A, Kielhorn L, Zimmermann S. An open source isolated data acquisition with trigger pulse generation for ion mobility spectrometry. HARDWAREX 2024; 20:e00600. [PMID: 39553919 PMCID: PMC11565032 DOI: 10.1016/j.ohx.2024.e00600] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/20/2024] [Revised: 10/16/2024] [Accepted: 10/19/2024] [Indexed: 11/19/2024]
Abstract
Ion mobility spectrometers (IMS) are used in a wide variety of applications, including trace gas detection in safety and security applications, but also in more analytical applications, e.g., in medicine or food quality monitoring. Consequently, IMS are often coupled with other separation techniques and laboratory equipment, requiring synchronization between the external equipment and the IMS electronics. In addition, IMS and the associated electronics are becoming increasingly complex due to ongoing instrumental developments. In this work, we present an open source data acquisition hardware tailored to the requirements of advanced IMS, but also applicable to other applications. The data acquisition hardware provides trigger pulses for synchronized operation of the IMS ion gate or external devices. In addition, the data acquisition hardware allows for parallel digitalization using two isolated 16-bit analog-to-digital converters (ADC) with up to 250 kilosamples per second. The galvanically isolated trigger input ensures a synchronized start of the IMS measurements, particularly when connecting external instrumentation such as a gas chromatograph. Furthermore, due to the isolated ADCs, the hardware allows great flexibility in defining the ground potential of the instrument setup.
Collapse
Affiliation(s)
- Tim Kobelt
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstr. 9A, 30167 Hannover, Germany
| | - Martin Lippmann
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstr. 9A, 30167 Hannover, Germany
| | - Alexander Nitschke
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstr. 9A, 30167 Hannover, Germany
| | - Lou Kielhorn
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstr. 9A, 30167 Hannover, Germany
| | - Stefan Zimmermann
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstr. 9A, 30167 Hannover, Germany
| |
Collapse
|
3
|
van der Loh M, Schiffmann M, Polack M, Wink K, Belder D. Coupling of droplet-on-demand microfluidcs with ESI/MS to study single-cell catalysis. RSC Adv 2024; 14:25337-25346. [PMID: 39139235 PMCID: PMC11320962 DOI: 10.1039/d4ra04835k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2024] [Accepted: 08/07/2024] [Indexed: 08/15/2024] Open
Abstract
Droplet microfluidics provides an efficient method for analysing reactions within the range of nanoliters to picoliters. However, the sensitive, label-free and versatile detection with ESI/MS poses some difficulties. One challenge is the difficult association of droplets with the MS signal in high-throughput droplet analysis. Hence, a droplet-on-demand system for the generation of a few droplets can address this and other problems such as surfactant concentration or cross-contamination. Accordingly, the system has been further developed for online coupling with ESI/MS. To achieve this, we developed a setup enabling on-demand droplet generation by hydrodynamic gating, with downstream microscopic droplet detection and MS analysis. This facilitated the incorporation of 1-9 yeast cells into individual 1-5 nL droplets and the monitoring of yeast-catalysed transformation from ketoester to ethyl-3-hydroxybutyrate by MS. With our method a mean production rate of 0.035 ± 0.017 fmol per cell per h was observed with a detection limit of 0.30 μM. In conclusion, our droplet-on-demand method is a versatile and advantageous tool for cell encapsulation in droplets, droplet imaging and reaction detection using ESI/MS.
Collapse
Affiliation(s)
- Marie van der Loh
- Institute of Analytical Chemistry, Leipzig University Linnéstraße 3 04103 Leipzig Germany
| | - Marie Schiffmann
- Institute of Analytical Chemistry, Leipzig University Linnéstraße 3 04103 Leipzig Germany
| | - Matthias Polack
- Institute of Analytical Chemistry, Leipzig University Linnéstraße 3 04103 Leipzig Germany
| | - Konstantin Wink
- Institute of Analytical Chemistry, Leipzig University Linnéstraße 3 04103 Leipzig Germany
| | - Detlev Belder
- Institute of Analytical Chemistry, Leipzig University Linnéstraße 3 04103 Leipzig Germany
| |
Collapse
|
4
|
Zohouri D, Lienard-Mayor T, Obeid S, Taverna M, Mai TD. A review on hyphenation of droplet microfluidics to separation techniques: From instrumental conception to analytical applications for limited sample volumes. Anal Chim Acta 2024; 1291:342090. [PMID: 38280779 DOI: 10.1016/j.aca.2023.342090] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Revised: 11/17/2023] [Accepted: 11/28/2023] [Indexed: 01/29/2024]
Abstract
In this study, we review various strategies to couple sample processing in microfluidic droplets with different separation techniques, including liquid chromatography, mass spectrometry, and capillary electrophoresis. Separation techniques interfaced with droplet microfluidics represent an emerging trend in analytical chemistry, in which micro to femtoliter droplets serve as microreactors, a bridge between analytical modules, as well as carriers of target analytes between sample treatment and separation/detection steps. This allows to overcome the hurdles encountered in separation science, notably the low degree of module integration, working volume incompatibility, and cross contamination between different operational stages. For this droplet-separation interfacing purpose, this review covers different instrumental designs from all works on this topic up to May 2023, together with our viewpoints on respective advantages and considerations. Demonstration and performance of droplet-interfaced separation strategies for limited sample volumes are also discussed.
Collapse
Affiliation(s)
- Delaram Zohouri
- Université Paris-Saclay, CNRS, Institut Galien Paris-Saclay, 91400, Orsay, France
| | - Théo Lienard-Mayor
- Université Paris-Saclay, CNRS, Institut Galien Paris-Saclay, 91400, Orsay, France
| | - Sameh Obeid
- Université Paris-Saclay, CNRS, Institut Galien Paris-Saclay, 91400, Orsay, France
| | - Myriam Taverna
- Université Paris-Saclay, CNRS, Institut Galien Paris-Saclay, 91400, Orsay, France
| | - Thanh Duc Mai
- Université Paris-Saclay, CNRS, Institut Galien Paris-Saclay, 91400, Orsay, France.
| |
Collapse
|
5
|
Thoben C, Schlottmann F, Kobelt T, Nitschke A, Gloeden GL, Naylor CN, Kirk AT, Zimmermann S. Ultra-Fast Ion Mobility Spectrometer for High-Throughput Chromatography. Anal Chem 2023; 95:17073-17081. [PMID: 37953497 PMCID: PMC10666085 DOI: 10.1021/acs.analchem.3c03935] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Revised: 10/26/2023] [Accepted: 10/30/2023] [Indexed: 11/14/2023]
Abstract
Fast chromatography systems especially developed for high sample throughput applications require sensitive detectors with a high repetition rate. These high throughput techniques, including various chip-based microfluidic designs, often benefit from detectors providing subsequent separation in another dimension, such as mass spectrometry or ion mobility spectrometry (IMS), giving additional information about the analytes or monitoring reaction kinetics. However, subsequent separation is required at a high repetition rate. Here, we therefore present an ultra-fast drift tube IMS operating at ambient pressure. Short drift times while maintaining high resolving power are reached by several key instrumental design features: short length of the drift tube, resistor network of the drift tube, tristate ion shutter, and improved data acquisition electronics. With these design improvements, even slow ions with a reduced mobility of just 0.94 cm2/(V s) have a drift time below 1.6 ms. Such short drift times allow for a significantly increased repetition rate of 600 Hz compared with previously reported values. To further reduce drift times and thus increase the repetition rate, helium can be used as the drift gas, which allows repetition rates of up to 2 kHz. Finally, these significant improvements enable IMS to be used as a detector following ultra-fast separation including chip-based chromatographic systems or droplet microfluidic applications requiring high repetition rates.
Collapse
Affiliation(s)
- Christian Thoben
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Florian Schlottmann
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Tim Kobelt
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Alexander Nitschke
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Gian-Luca Gloeden
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Cameron N. Naylor
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Ansgar T. Kirk
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Stefan Zimmermann
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| |
Collapse
|
6
|
Chen X, Zhang D, Liu Q, Liu S, Li H, Li Z. Enzyme-Linked Immunosorbent Assay-Based Microarray on a Chip for Bioaerosol Sensing: Toward Sensitive and Multiplexed Profiling of Foodborne Allergens. Anal Chem 2023; 95:7354-7362. [PMID: 37098245 DOI: 10.1021/acs.analchem.3c00591] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/27/2023]
Abstract
Food allergy has become a growing health concern that may impair life quality and even cause life-threatening outcomes. Accidental and continuous exposure to allergenic bioaerosols has a substantially negative impact on the respiratory health of patients. Traditional analytical methodologies for food allergens are restricted by strong reliance on bulk instrumentation and skilled personnel, particularly in low-resource settings. In this study, a fluorescent sensor array based on the enzyme-linked immunosorbent assay performed on a herringbone-shaped microfluidic chip (ELISA-HB-chip) was designed for dynamically sensitive and multiplexed quantification of foodborne allergens in aerosols that originated from liquid food extracts. Due to the high surface area of aerosol particles and sufficient mixing of immunological reagents using a herringbone micromixer, the detection sensitivity was improved by over an order of magnitude compared to traditional allergen detection in the aqueous phase. Through fluorescence imaging of multiple regions on the ELISA-HB-chip, four important foodborne allergens, namely, ovalbumin, ovomucoid, lysozyme, and tropomyosin, could be simultaneously monitored without any cross-reactivity, and the limits of detection for these allergenic species were determined to be 7.8, 1.2, 4.2, and 0.31 ng/mL, respectively. Combining with a 3D printed and portable fluorescence microscope, this platform exhibited an excellent field-deployable capacity for quick and accurate determination of allergens in the aerosol state from spiked buffer solutions, thus displaying the practicality for food safety screening at cooking or food processing sites where patients are potentially under exposure to allergenic bioaerosols that escaped from food matrices or extracts.
Collapse
Affiliation(s)
- Xiaofeng Chen
- Institute for Advanced Study, Shenzhen University, Shenzhen, Guangdong 518060, China
| | - Dongdong Zhang
- Tianjin First Central Hospital, School of Medicine, Nankai University, Tianjin 300071, China
| | - Qingmei Liu
- College of Ocean Food and Biologic Engineering, Jimei University, Xiamen, Fujian 361021, China
| | - Sihui Liu
- Institute for Advanced Study, Shenzhen University, Shenzhen, Guangdong 518060, China
| | - Houlin Li
- Institute for Advanced Study, Shenzhen University, Shenzhen, Guangdong 518060, China
| | - Zheng Li
- Institute for Advanced Study, Shenzhen University, Shenzhen, Guangdong 518060, China
| |
Collapse
|
7
|
Recent advances of integrated microfluidic systems for fungal and bacterial analysis. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116850] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
8
|
D'Amico CI, Polasky DA, Steyer DJ, Ruotolo BT, Kennedy RT. Ion Mobility-Mass Spectrometry Coupled to Droplet Microfluidics for Rapid Protein Structure Analysis and Drug Discovery. Anal Chem 2022; 94:13084-13091. [PMID: 36098981 DOI: 10.1021/acs.analchem.2c02307] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Native mass spectrometry coupled to ion mobility (IM-MS) has become an important tool for the investigation of protein structure and dynamics upon ligand binding. Additionally, collisional activation or collision induced unfolding (CIU) can further probe conformational changes induced by ligand binding; however, larger scale screens have not been implemented due to limitations associated with throughput and sample introduction. In this work we explore the high-throughput capabilities of CIU fingerprinting. Fingerprint collection times were reduced 10-fold over traditional data collections through the use of improved smoothing and interpolation algorithms. Fast-CIU was then coupled to a droplet sample introduction approach using 40 nL droplet sample volumes and 2 s dwell times at each collision voltage. This workflow, which increased throughput by ∼16-fold over conventional nanospray CIU methods, was applied to a 96-compound screen against Sirtuin-5, a protein target of clinical interest. Over 20 novel Sirtuin-5 binders were identified, and it was found that Sirtuin-5 inhibitors will stabilize specific Sirtuin-5 gas-phase conformations. This work demonstrates that droplet-CIU can be implemented as a high-throughput biophysical characterization approach. Future work will focus on improving the throughput of this workflow and on automating data acquisition and analysis.
Collapse
Affiliation(s)
- Cara I D'Amico
- Department of Pharmacology, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Daniel A Polasky
- Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Daniel J Steyer
- Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Brandon T Ruotolo
- Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Robert T Kennedy
- Department of Pharmacology, University of Michigan, Ann Arbor, Michigan 48109, United States.,Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States
| |
Collapse
|
9
|
Wink K, van der Loh M, Hartner N, Polack M, Dusny C, Schmid A, Belder D. Quantification of Biocatalytic Transformations by Single Microbial Cells Enabled by Tailored Integration of Droplet Microfluidics and Mass Spectrometry. Angew Chem Int Ed Engl 2022; 61:e202204098. [PMID: 35511505 PMCID: PMC9401594 DOI: 10.1002/anie.202204098] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2022] [Indexed: 12/23/2022]
Abstract
Improving the performance of chemical transformations catalysed by microbial biocatalysts requires a deep understanding of cellular processes. While the cellular heterogeneity of cellular characteristics, such as the concentration of high abundant cellular content, is well studied, little is known about the reactivity of individual cells and its impact on the chemical identity, quantity, and purity of excreted products. Biocatalytic transformations were monitored chemically specific and quantifiable at the single-cell level by integrating droplet microfluidics, cell imaging, and mass spectrometry. Product formation rates for individual Saccharomyces cerevisiae cells were obtained by i) incubating nanolitre-sized droplets for product accumulation in microfluidic devices, ii) an imaging setup to determine the number of cells in the droplets, and iii) electrospray ionisation mass spectrometry for reading the chemical contents of individual droplets. These findings now enable the study of whole-cell biocatalysis at single-cell resolution.
Collapse
Affiliation(s)
- Konstantin Wink
- University of LeipzigInstitute of Analytical Chemistry04107LeipzigGermany
| | - Marie van der Loh
- University of LeipzigInstitute of Analytical Chemistry04107LeipzigGermany
| | - Nora Hartner
- University of LeipzigInstitute of Analytical Chemistry04107LeipzigGermany
| | - Matthias Polack
- University of LeipzigInstitute of Analytical Chemistry04107LeipzigGermany
| | - Christian Dusny
- Department Solar MaterialsHelmholtz Centre for Environmental Research (UFZ)04318LeipzigGermany
| | - Andreas Schmid
- Department Solar MaterialsHelmholtz Centre for Environmental Research (UFZ)04318LeipzigGermany
| | - Detlev Belder
- University of LeipzigInstitute of Analytical Chemistry04107LeipzigGermany
| |
Collapse
|
10
|
Teixidor J, Novello S, Ortiz D, Menin L, Lashuel HA, Bertsch A, Renaud P. On-Demand Nanoliter Sampling Probe for the Collection of Brain Fluid. Anal Chem 2022; 94:10415-10426. [PMID: 35786947 DOI: 10.1021/acs.analchem.2c01577] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Continuous fluidic sampling systems allow collection of brain biomarkers in vivo. Here, we propose a new sequential and intermittent sampling paradigm using droplets, called Droplet on Demand (DoD). It is implemented in a microfabricated neural probe and alternates phases of analyte removal from the tissue and phases of equilibration of the concentration in the tissue. It allows sampling droplets loaded with molecules from the brain extracellular fluid punctually, without the long transient equilibration periods typical of continuous methods. It uses an accurately defined fluidic sequence with controlled timings, volumes, and flow rates, and correct operation is verified by the embedded electrodes and a flow sensor. As a proof of concept, we demonstrated the application of this novel approach in vitro and in vivo, to collect glucose in the brain of mice, with a temporal resolution of 1-2 min and without transient regime. Absolute quantification of the glucose level in the samples was performed by direct infusion nanoelectrospray ionization Fourier transform mass spectrometry (nanoESI-FTMS). By adjusting the diffusion time and the perfusion volume of DoD, the fraction of molecules recovered in the samples can be tuned to mirror the tissue concentration at accurate points in time. Moreover, this makes quantification of biomarkers in the brain possible within acute experiments of only 20-120 min. DoD provides a complementary tool to continuous microdialysis and push-pull sampling probes. Thus, the advances allowed by DoD will benefit quantitative molecular studies in the brain, i.e., for molecules involved in volume transmission or for protein aggregates that form in neurodegenerative diseases over long periods.
Collapse
Affiliation(s)
- Joan Teixidor
- Microsystems Laboratory 4 (STI-IEM-LMIS4), École Polytechnique Fédérale de Lausanne (EPFL), 1015 Lausanne, Switzerland
| | - Salvatore Novello
- Laboratory of Molecular and Chemical Biology of Neurodegeneration (SV-BMI-LMNN), EPFL, 1015 Lausanne, Switzerland
| | - Daniel Ortiz
- Mass Spectrometry and Elemental Analysis Platform (SB-ISIC-MSEAP), EPFL, 1015 Lausanne, Switzerland
| | - Laure Menin
- Mass Spectrometry and Elemental Analysis Platform (SB-ISIC-MSEAP), EPFL, 1015 Lausanne, Switzerland
| | - Hilal A Lashuel
- Laboratory of Molecular and Chemical Biology of Neurodegeneration (SV-BMI-LMNN), EPFL, 1015 Lausanne, Switzerland
| | - Arnaud Bertsch
- Microsystems Laboratory 4 (STI-IEM-LMIS4), École Polytechnique Fédérale de Lausanne (EPFL), 1015 Lausanne, Switzerland
| | - Philippe Renaud
- Microsystems Laboratory 4 (STI-IEM-LMIS4), École Polytechnique Fédérale de Lausanne (EPFL), 1015 Lausanne, Switzerland
| |
Collapse
|
11
|
Wink K, Loh M, Hartner N, Polack M, Dusny C, Schmid A, Belder D. Quantifizierung biokatalytischer Umwandlungen durch einzelne mikrobielle Zellen mittels maßgeschneiderter Integration von Tröpfchenmikrofluidik und Massenspektrometrie. Angew Chem Int Ed Engl 2022. [DOI: 10.1002/ange.202204098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- Konstantin Wink
- Universität Leipzig Institut für Analytische Chemie 04107 Leipzig Deutschland
| | - Marie Loh
- Universität Leipzig Institut für Analytische Chemie 04107 Leipzig Deutschland
| | - Nora Hartner
- Universität Leipzig Institut für Analytische Chemie 04107 Leipzig Deutschland
| | - Matthias Polack
- Universität Leipzig Institut für Analytische Chemie 04107 Leipzig Deutschland
| | - Christian Dusny
- Department Solare Materialien Helmholtz-Zentrum für Umweltforschung (UFZ) 04318 Leipzig Deutschland
| | - Andreas Schmid
- Department Solare Materialien Helmholtz-Zentrum für Umweltforschung (UFZ) 04318 Leipzig Deutschland
| | - Detlev Belder
- Universität Leipzig Institut für Analytische Chemie 04107 Leipzig Deutschland
| |
Collapse
|
12
|
Wang M, Liao X, Tchounwou PB, Liu YM. Coupling a droplet generator with conventional ESI-MS for quantitative analysis of small-volume samples. Anal Bioanal Chem 2022; 414:1809-1817. [PMID: 35061061 PMCID: PMC8828272 DOI: 10.1007/s00216-021-03808-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2021] [Revised: 11/22/2021] [Accepted: 11/25/2021] [Indexed: 02/03/2023]
Abstract
Quantitative mass spectrometric analysis of small-volume samples (e.g., < 1 μL) has been a challenge mainly due to the difficulties with sample handling and its injection into the system for analysis. Herein we report a microfluidic analytical platform coupling a droplet generator with conventional electrospray ionization-mass spectrometry (ESI-MS) that enables multiple analyses of a μL-sized sample with sensitivity and repeatability. In an analysis by droplet generator-assisted ESI-MS (DG-ESI-MS), a sample of μL volume is pulled into a sampling capillary and its equal nL-sized portions are generated by a droplet generator and analyzed by ESI-MS at time intervals of choice. The droplet generator is made of PMMA sheets by laser engraving conveniently and at a low cost. In a study to achieve effective ESI-MS detection of water-in-oil droplets, it's found that the problem of MS signal suppression by oil can be solved by using an appropriate organic carrier with ESI-enhancing additives. The proposed DG-ESI-MS method has linear calibration curves for both adenine and phenylalanine with LODs at the sub-μM level. Application of the present analytical platform for monitoring substrate concentration changes in an enzymatic reaction solution of 3 μL is demonstrated.
Collapse
Affiliation(s)
- Meiyuan Wang
- Department of Chemistry and Biochemistry, Jackson State University, Jackson, MS 39217, USA
| | - Xun Liao
- Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu, Sichuan 610041, China
| | - Paul B. Tchounwou
- Department of Biology, Jackson State University, 1400 Lynch Street, Jackson, MS 39217, USA
| | - Yi-Ming Liu
- Department of Chemistry and Biochemistry, Jackson State University, Jackson, MS 39217, USA
| |
Collapse
|