1
|
Isom M, Desaire H. Skin Surface Sebum Analysis by ESI-MS. Biomolecules 2024; 14:790. [PMID: 39062504 PMCID: PMC11274890 DOI: 10.3390/biom14070790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2024] [Revised: 06/26/2024] [Accepted: 06/28/2024] [Indexed: 07/28/2024] Open
Abstract
The skin surface is an important sample source that the metabolomics community has only just begun to explore. Alterations in sebum, the lipid-rich mixture coating the skin surface, correlate with age, sex, ethnicity, diet, exercise, and disease state, making the skin surface an ideal sample source for future noninvasive biomarker exploration, disease diagnosis, and forensic investigation. The potential of sebum sampling has been realized primarily via electrospray ionization mass spectrometry (ESI-MS), an ideal approach to assess the skin surface lipidome. However, a better understanding of sebum collection and subsequent ESI-MS analysis is required before skin surface sampling can be implemented in routine analyses. Challenges include ambiguity in definitive lipid identification, inherent biological variability in sebum production, and methodological, technical variability in analyses. To overcome these obstacles, avoid common pitfalls, and achieve reproducible, robust outcomes, every portion of the workflow-from sample collection to data analysis-should be carefully considered with the specific application in mind. This review details current practices in sebum sampling, sample preparation, ESI-MS data acquisition, and data analysis, and it provides important considerations in acquiring meaningful lipidomic datasets from the skin surface. Forensic researchers investigating sebum as a means for suspect elimination in lieu of adequate fingerprint ridge detail or database matches, as well as clinical researchers interested in noninvasive biomarker exploration, disease diagnosis, and treatment monitoring, can use this review as a guide for developing methods of best-practice.
Collapse
Affiliation(s)
| | - Heather Desaire
- Department of Chemistry, University of Kansas, Lawrence, KS 66045, USA;
| |
Collapse
|
2
|
Lee CW, Su H, Hsu YW, Su LZ, Wu YH, Hou CY, Shih SY, Shiea J. Rapid Characterization of Undeclared Pharmaceuticals in Herbal Preparations by Ambient Ionization Mass Spectrometry for Emergency Care. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024; 35:960-971. [PMID: 38616559 PMCID: PMC11066970 DOI: 10.1021/jasms.4c00016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/13/2024] [Revised: 03/12/2024] [Accepted: 04/09/2024] [Indexed: 04/16/2024]
Abstract
In Asia, some herbal preparations have been found to be adulterated with undeclared synthetic medicines to increase their therapeutic efficiency. Many of these adulterants were found to be toxic when overdosed and have been documented to bring about severe, even life-threatening acute poisoning events. The objective of this study is to develop a rapid and sensitive ambient ionization mass spectrometric platform to characterize the undeclared toxic adulterated ingredients in herbal preparations. Several common adulterants were spiked into different herbal preparations and human sera to simulate the clinical conditions of acute poisoning. They were then sampled with a metallic probe and analyzed by the thermal desorption-electrospray ionization mass spectrometry. The experimental parameters including sensitivity, specificity, accuracy, and turnaround time were prudently optimized in this study. Since tedious and time-consuming pretreatment of the sample is unnecessary, the toxic adulterants could be characterized within 60 s. The results can help emergency physicians to make clinical judgments and prescribe appropriate antidotes or supportive treatment in a time-sensitive manner.
Collapse
Affiliation(s)
- Chi-Wei Lee
- Institute
of Medical Science and Technology, National
Sun Yat-Sen University, Kaohsiung 804201, Taiwan, ROC
- Rapid
Screening Research Center for Toxicology and Biomedicine, National Sun Yat-Sen University, Kaohsiung 804201, Taiwan, ROC
- Research
Center for Environmental Medicine, Kaohsiung
Medical University, Kaohsiung 80756, Taiwan, ROC
| | - Hung Su
- Department
of Chemistry, National Sun Yat-Sen University, Kaohsiung 804201, Taiwan, ROC
| | - Yi-Wen Hsu
- Institute
of Medical Science and Technology, National
Sun Yat-Sen University, Kaohsiung 804201, Taiwan, ROC
| | - Lin-Zhen Su
- Institute
of Medical Science and Technology, National
Sun Yat-Sen University, Kaohsiung 804201, Taiwan, ROC
| | - Yen-Hung Wu
- Department
of Emergency Medicine, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung 80756, Taiwan, ROC
| | - Chia-Yi Hou
- Department
of Clinical Pathology, Chi-Mei Medical Center, Liouying 73659, Taiwan, ROC
| | - Shu-Yu Shih
- Department
of Emergency Medicine, Chi-Mei Medical Center, Liouying 73659, Taiwan, ROC
| | - Jentaie Shiea
- Department
of Chemistry, National Sun Yat-Sen University, Kaohsiung 804201, Taiwan, ROC
- Department
of Medicinal and Applied Chemistry, Kaohsiung
Medical University, Kaohsiung 80756, Taiwan, ROC
- Rapid
Screening Research Center for Toxicology and Biomedicine, National Sun Yat-Sen University, Kaohsiung 804201, Taiwan, ROC
- Research
Center for Environmental Medicine, Kaohsiung
Medical University, Kaohsiung 80756, Taiwan, ROC
| |
Collapse
|
3
|
Conway C, Weber M, Ferranti A, Wolf JC, Haisch C. Rapid desorption and analysis for illicit drugs and chemical profiling of fingerprints by SICRIT ion source. Drug Test Anal 2023. [PMID: 38155431 DOI: 10.1002/dta.3623] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 10/26/2023] [Accepted: 11/10/2023] [Indexed: 12/30/2023]
Abstract
Forensic analysis can encompass a wide variety of analytes from biological samples including DNA, blood, serum, and fingerprints to synthetic samples like drugs and explosives. In order to analyze this variety, there are various sample preparation techniques, which can be time-consuming and require multiple analytical instruments. With recent advancements in ambient ionization mass spectrometry (MS), plasma-based dielectric barrier discharge ionization (DBDI) sources have demonstrated to cover a wide range of these analytes. The flow-through design of this source also allows for easy connection to a thermal desorption type of sample introduction. We present an in-house built thermal desorption device where the sample is introduced via a glass slide, which gets heated and transferred to the DBDI-MS with nitrogen for identification and semi-quantification. Using a glass slide as an inexpensive sampling device, detection limits as low as 20 pg for fentanyl are demonstrated. Additionally, a very precise (>96% accuracy) identification of persons based on the chemical profile of their fingerprints is possible, establishing a direct analytical link of the drug trace to the individual in one measurement. We compared the DAG, TAG, sterol, and (semi-)volatile region of the averaged fingerprint spectra over multiple days, showing the best model accuracy for identification based on the DAG region. The combination of thermal desorption and DBDI-MS minimized sample preparation, leading to an ultrasensitive and rapid analysis of illicit drug traces and the identification of underlying personas based on fingerprints.
Collapse
Affiliation(s)
- Ciara Conway
- Department of Analytical Chemistry and Water Chemistry, Technical University of Munich, Garching, Germany
- Plasmion GmbH, Augsburg, Germany
| | | | | | | | - Christoph Haisch
- Department of Analytical Chemistry and Water Chemistry, Technical University of Munich, Garching, Germany
| |
Collapse
|
4
|
Hiraoka K, Shimada H, Kinoshita K, Rankin-Turner S, Ninomiya S. Analysis of human skin sebum and animal meats by heat pulse desorption/mass spectrometry using proximity corona discharge ionization. Anal Biochem 2023:115249. [PMID: 37454965 DOI: 10.1016/j.ab.2023.115249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Revised: 07/06/2023] [Accepted: 07/14/2023] [Indexed: 07/18/2023]
Abstract
Recently, we have developed heat pulse desorption/mass spectrometry (HPD/MS). In HPD/MS, a heated N2 gas pulse was directed to the sample surface and desorbed analytes were mass analyzed by corona discharge ionization/mass spectrometry using an Orbitrap mass spectrometer. In this work, HPD/MS was applied to the analysis of skin surface components sampled from the forehead, nose, and jaw of three volunteers. It was found that various kinds of biological compounds such as squalene, free fatty acids, wax esters, triacylglycerols, and amino acids were detected. The simultaneous detection of compounds with a wide range of proton affinities suggests that the occurrence of consecutive proton transfer reactions is less likely to occur in the present experimental system. This is mainly due to the short distance of 1.5 mm between the tip of the corona needle and the inlet of the mass spectrometer (i.e., proximity corona discharge ion source). Under this condition, the transition time of the primary reactant ions (e.g., H3O+) from the tip of the corona discharge needle to the ion sampling orifice is roughly estimated to be ∼20 μs. This value nearly corresponds to the reaction lifetime of exoergic proton transfer reactions with a rate constant: ∼10-9 cm3 s-1 for the analytes of 1 ppm. Accordingly, analytes with concentrations less than 1 ppm would be ionized semi-quantitatively by the present method, making this method highly suitable for the rapid analysis of samples composed of complex mixture of compounds, e.g., non-target lipidomics.
Collapse
Affiliation(s)
- Kenzo Hiraoka
- Clean Energy Research Center, University of Yamanashi, 4-3-11 Takeda, Kofu, Yamanashi, 400-8511, Japan.
| | - Haruo Shimada
- BioChromato, Inc. 1-12-19 Honcho, Fujisawa, Kanagawa, 251-0053, Japan
| | | | - Stephanie Rankin-Turner
- Department of Molecular Microbiology & Immunology, Johns Hopkins Bloomberg School of Public Health, 615 N. Wolfe Street, Baltimore, MD, 21205, USA
| | - Satoshi Ninomiya
- Clean Energy Research Center, University of Yamanashi, 4-3-11 Takeda, Kofu, Yamanashi, 400-8511, Japan.
| |
Collapse
|
5
|
Géhin C, Tokarska J, Fowler SJ, Barran PE, Trivedi DK. No skin off your back: the sampling and extraction of sebum for metabolomics. Metabolomics 2023; 19:21. [PMID: 36964290 PMCID: PMC10038389 DOI: 10.1007/s11306-023-01982-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Accepted: 02/19/2023] [Indexed: 03/26/2023]
Abstract
INTRODUCTION Sebum-based metabolomics (a subset of "sebomics") is a developing field that involves the sampling, identification, and quantification of metabolites found in human sebum. Sebum is a lipid-rich oily substance secreted by the sebaceous glands onto the skin surface for skin homeostasis, lubrication, thermoregulation, and environmental protection. Interest in sebomics has grown over the last decade due to its potential for rapid analysis following non-invasive sampling for a range of clinical and environmental applications. OBJECTIVES To provide an overview of various sebum sampling techniques with their associated challenges. To evaluate applications of sebum for clinical research, drug monitoring, and human biomonitoring. To provide a commentary of the opportunities of using sebum as a diagnostic biofluid in the future. METHODS Bibliometric analyses of selected keywords regarding skin surface analysis using the Scopus search engine from 1960 to 2022 was performed on 12th January 2023. The published literature was compartmentalised based on what the work contributed to in the following areas: the understanding about sebum, its composition, the analytical technologies used, or the purpose of use of sebum. The findings were summarised in this review. RESULTS Historically, about 15 methods of sampling have been used for sebum collection. The sample preparation approaches vary depending on the analytes of interest and are summarised. The use of sebum is not limited to just skin diseases or drug monitoring but also demonstrated for other systemic disease. Most of the work carried out for untargeted analysis of metabolites associated with sebum has been in the recent two decades. CONCLUSION Sebum has a huge potential beyond skin research and understanding how one's physiological state affects or reflects on the skin metabolome via the sebaceous glands itself or by interactions with sebaceous secretion, will open doors for simpler biomonitoring. Sebum acts as a sink to environmental metabolites and has applications awaiting to be explored, such as biosecurity, cross-border migration, localised exposure to harmful substances, and high-throughput population screening. These applications will be possible with rapid advances in volatile headspace and lipidomics method development as well as the ability of the metabolomics community to annotate unknown species better. A key issue with skin surface analysis that remains unsolved is attributing the source of the metabolites found on the skin surface before meaningful biological interpretation.
Collapse
Affiliation(s)
- C Géhin
- School of Chemistry, Manchester Institute of Biotechnology, University of Manchester, Princess Street, Manchester, M1 7DN, UK
| | - J Tokarska
- School of Chemistry, Manchester Institute of Biotechnology, University of Manchester, Princess Street, Manchester, M1 7DN, UK
| | - S J Fowler
- Department of Respiratory Medicine, Manchester University Hospitals NHS Foundation Trust, Manchester, UK
- Faculty of Biology, Medicine and Health, School of Biological Sciences, University of Manchester, Manchester, UK
- NIHR Manchester Biomedical Research Centre, Manchester University Hospitals NHS Foundation Trust, Manchester, UK
| | - P E Barran
- School of Chemistry, Manchester Institute of Biotechnology, University of Manchester, Princess Street, Manchester, M1 7DN, UK
| | - D K Trivedi
- School of Chemistry, Manchester Institute of Biotechnology, University of Manchester, Princess Street, Manchester, M1 7DN, UK.
| |
Collapse
|