1
|
Jeon CK, Rojas Ramirez C, Makey DM, Kurulugama RT, Ruotolo BT. CIUSuite 3: Next-Generation CCS Calibration and Automated Data Analysis Tools for Gas-Phase Protein Unfolding Data. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024; 35:1865-1874. [PMID: 38967378 DOI: 10.1021/jasms.4c00176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/06/2024]
Abstract
Ion mobility-mass spectrometry (IM-MS) has become a technology deployed across a wide range of structural biology applications despite the challenges in characterizing closely related protein structures. Collision-induced unfolding (CIU) has emerged as a valuable technique for distinguishing closely related, iso-cross-sectional protein and protein complex ions through their distinct unfolding pathways in the gas phase. With the speed and sensitivity of CIU analyses, there has been a rapid growth of CIU-based assays, especially regarding biomolecular targets that remain challenging to assess and characterize with other structural biology tools. With information-rich CIU data, many software tools have been developed to automate laborious data analysis. However, with the recent development of new IM-MS technologies, such as cyclic IM-MS, CIU continues to evolve, necessitating improved data analysis tools to keep pace with new technologies and facilitating the automation of various data processing tasks. Here, we present CIUSuite 3, a software package that contains updated algorithms that support various IM-MS platforms and supports the automation of various data analysis tasks such as peak detection, multidimensional classification, and collision cross section (CCS) calibration. CIUSuite 3 uses local maxima searches along with peak width and prominence filters to detect peaks to automate CIU data extraction. To support both the primary CIU (CIU1) and secondary CIU (CIU2) experiments enabled by cyclic IM-MS, two-dimensional data preprocessing is deployed, which allows multidimensional classification. Our data suggest that additional dimensions in classification improve the overall accuracy of class assignments. CIUSuite 3 also supports CCS calibration for both traveling wave and drift tube IM-MS, and we demonstrate the accuracy of a new single-field CCS calibration method designed for drift tube IM-MS leveraging calibrant CIU data. Overall, CIUSuite 3 is positioned to support current and next-generation IM-MS and CIU assay development deployed in an automated format.
Collapse
Affiliation(s)
- Chae Kyung Jeon
- Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States
| | | | - Devin M Makey
- Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States
| | | | - Brandon T Ruotolo
- Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States
| |
Collapse
|
2
|
Yang Y, Vagin SI, Rieger B, Destgeer G. Fabrication of Crescent Shaped Microparticles for Particle Templated Droplet Formation. Macromol Rapid Commun 2024; 45:e2300721. [PMID: 38615246 DOI: 10.1002/marc.202300721] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Revised: 04/08/2024] [Indexed: 04/15/2024]
Abstract
Crescent-shaped hydrogel microparticles are shown to template uniform volume aqueous droplets upon simple mixing with aqueous and oil media for various bioassays. This emerging "lab on a particle" technique requires hydrogel particles with tunable material properties and dimensions. The crescent shape of the particles is attained by aqueous two-phase separation of polymers followed by photopolymerization of the curable precursor. In this work, the phase separation of poly(ethylene glycol) diacrylate (PEGDA, Mw 700) and dextran (Mw 40 000) for tunable manufacturing of crescent-shaped particles is investigated. The particles' morphology is precisely tuned by following a phase diagram, varying the UV intensity, and adjusting the flow rates of various streams. The fabricated particles with variable dimensions encapsulate uniform aqueous droplets upon mixing with an oil phase. The particles are fluorescently labeled with red and blue emitting dyes at variable concentrations to produce six color-coded particles. The blue fluorescent dye shows a moderate response to the pH change. The fluorescently labeled particles are able to tolerate an extremely acidic solution (pH 1) but disintegrate within an extremely basic solution (pH 14). The particle-templated droplets are able to effectively retain the disintegrating particle and the fluorescent signal at pH 14.
Collapse
Affiliation(s)
- Yimin Yang
- Control and Manipulation of Microscale Living Objects, Department of Electrical Engineering, TUM School of Computation, Information and Technology, TranslaTUM - Center for Translational Cancer Research, Technical University of Munich, Einsteinstraße 25, 81675, Munich, Germany
| | - Sergei I Vagin
- WACKER-Chair of Macromolecular Chemistry, Department of Chemistry, TUM School of Natural Sciences, Technical University of Munich, Lichtenbergstraße 4, 85748, Garching, Germany
| | - Bernhard Rieger
- WACKER-Chair of Macromolecular Chemistry, Department of Chemistry, TUM School of Natural Sciences, Technical University of Munich, Lichtenbergstraße 4, 85748, Garching, Germany
| | - Ghulam Destgeer
- Control and Manipulation of Microscale Living Objects, Department of Electrical Engineering, TUM School of Computation, Information and Technology, TranslaTUM - Center for Translational Cancer Research, Technical University of Munich, Einsteinstraße 25, 81675, Munich, Germany
| |
Collapse
|
3
|
Guo Z, Zhao Y, Jin Z, Chang Y, Wang X, Guo G, Zhao Y. Monolithic 3D nanoelectrospray emitters based on a continuous fluid-assisted etching strategy for glass droplet microfluidic chip-mass spectrometry. Chem Sci 2024; 15:7781-7788. [PMID: 38784731 PMCID: PMC11110156 DOI: 10.1039/d4sc01700e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2024] [Accepted: 04/23/2024] [Indexed: 05/25/2024] Open
Abstract
Glass microfluidic chips are suitable for coupling with mass spectrometry (MS) due to their flexible design, optical transparency and resistance to organic reagents. However, due to the high hardness and brittleness of glass, there is a lack of simple and feasible technology to manufacture a monolithic nanospray ionization (nESI) emitter on a glass microchip, which hinders its coupling with mass spectrometry. Here, a continuous fluid-assisted etching strategy is proposed to fabricate monolithic three-dimensional (3D) nESI emitters integrated into glass microchips. A continuous fluid of methanol is adopted to protect the inner wall of the channels and the bonding interface of the glass microfluidic chip from being wet-etched, forming sharp 3D nESI emitters. The fabricated 3D nESI emitter can form a stable electrospray plume, resulting in consistent nESI detection of acetylcholine with an RSD of 4.5% within 10 min. The fabricated 3D emitter is integrated on a glass microfluidic chip designed with a T-junction droplet generator, which can realize efficient analysis of acetylcholine in picoliter-volume droplets by nESI-MS. Stability testing of over 20 000 droplets detected by the established system resulted in an RSD of 9.1% over approximately 180 min. The detection of ten neurochemicals in rat cerebrospinal fluid droplets is achieved. The established glass droplet microfluidic chip-MS system exhibits potential for broad applications such as in vivo neurochemical monitoring and single-cell analysis in the future.
Collapse
Affiliation(s)
- Ziyang Guo
- Department of Chemistry, Beijing University of Technology Beijing 100124 China
| | - Yingqi Zhao
- Department of Chemistry, Beijing University of Technology Beijing 100124 China
| | - Zhao Jin
- Department of Chemistry, Beijing University of Technology Beijing 100124 China
| | - Yaran Chang
- Department of Chemistry, Beijing University of Technology Beijing 100124 China
| | - Xiayan Wang
- Department of Chemistry, Beijing University of Technology Beijing 100124 China
| | - Guangsheng Guo
- Department of Chemistry, Beijing University of Technology Beijing 100124 China
- Minzu University of China Beijing 100081 China
| | - Yaoyao Zhao
- Department of Chemistry, Beijing University of Technology Beijing 100124 China
| |
Collapse
|
4
|
Zohouri D, Lienard-Mayor T, Obeid S, Taverna M, Mai TD. A review on hyphenation of droplet microfluidics to separation techniques: From instrumental conception to analytical applications for limited sample volumes. Anal Chim Acta 2024; 1291:342090. [PMID: 38280779 DOI: 10.1016/j.aca.2023.342090] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Revised: 11/17/2023] [Accepted: 11/28/2023] [Indexed: 01/29/2024]
Abstract
In this study, we review various strategies to couple sample processing in microfluidic droplets with different separation techniques, including liquid chromatography, mass spectrometry, and capillary electrophoresis. Separation techniques interfaced with droplet microfluidics represent an emerging trend in analytical chemistry, in which micro to femtoliter droplets serve as microreactors, a bridge between analytical modules, as well as carriers of target analytes between sample treatment and separation/detection steps. This allows to overcome the hurdles encountered in separation science, notably the low degree of module integration, working volume incompatibility, and cross contamination between different operational stages. For this droplet-separation interfacing purpose, this review covers different instrumental designs from all works on this topic up to May 2023, together with our viewpoints on respective advantages and considerations. Demonstration and performance of droplet-interfaced separation strategies for limited sample volumes are also discussed.
Collapse
Affiliation(s)
- Delaram Zohouri
- Université Paris-Saclay, CNRS, Institut Galien Paris-Saclay, 91400, Orsay, France
| | - Théo Lienard-Mayor
- Université Paris-Saclay, CNRS, Institut Galien Paris-Saclay, 91400, Orsay, France
| | - Sameh Obeid
- Université Paris-Saclay, CNRS, Institut Galien Paris-Saclay, 91400, Orsay, France
| | - Myriam Taverna
- Université Paris-Saclay, CNRS, Institut Galien Paris-Saclay, 91400, Orsay, France
| | - Thanh Duc Mai
- Université Paris-Saclay, CNRS, Institut Galien Paris-Saclay, 91400, Orsay, France.
| |
Collapse
|
5
|
Hu H, Singh AN, Lehnherr D, Mdluli V, Chun SW, Makarewicz AM, Gouker JR, Ukaegbu O, Li S, Wen X, McLaren DG, Velasquez JE, Moore JC, Galanie S, Appiah-Amponsah E, Regalado EL. Accelerating Pharmaceutical Process Development with an Acoustic Droplet Ejection-Multiple Reaction Monitoring-Mass Spectrometry Workflow. Anal Chem 2024; 96:1138-1146. [PMID: 38165811 DOI: 10.1021/acs.analchem.3c04211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2024]
Abstract
Fast-paced pharmaceutical process developments (e.g., high-throughput experimentation, directed evolution, and machine learning) involve the introduction of fast, sensitive, and accurate analytical assays using limited sample volumes. In recent years, acoustic droplet ejection (ADE) coupled with an open port interface has been invented as a sampling technology for mass spectrometry, providing high-throughput nanoliter analytical measurements directly from the standard microplates. Herein, we introduce an ADE-multiple reaction monitoring-mass spectrometry (ADE-MRM-MS) workflow to accelerate pharmaceutical process research and development (PR&D). This systematic workflow outlines the selection of MRM transitions and optimization of assay parameters in a data-driven manner using rapid measurements (1 sample/s). The synergy between ADE sampling and MRM analysis enables analytical assays with excellent sensitivity, selectivity, and speed for PR&D reaction screenings. This workflow was utilized to develop new ADE-MRM-MS assays guiding a variety of industrial processes, including (1) screening of Ni-based catalysts for C-N cross-coupling reaction at 1 Hz and (2) high-throughput regioisomer analysis-enabled enzyme library screening for peptide ligation reaction. ADE-MRM-MS assays were demonstrated to deliver accurate results that are comparable to conventional liquid chromatography (LC) experiments while providing >100-fold throughput enhancement.
Collapse
Affiliation(s)
- Hang Hu
- Analytical Research and Development, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Andrew N Singh
- Analytical Research and Development, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Dan Lehnherr
- Process Research and Development, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Velabo Mdluli
- Process Research and Development, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Stephanie W Chun
- Process Research and Development, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Amanda M Makarewicz
- Process Research and Development, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Joseph R Gouker
- Process Research and Development, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Ophelia Ukaegbu
- Analytical Research and Development, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Shasha Li
- Analytical Research and Development, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Xiujuan Wen
- Quantitative Biosciences, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - David G McLaren
- Quantitative Biosciences, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Juan E Velasquez
- Process Research and Development, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Jeffrey C Moore
- Process Research and Development, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Stephanie Galanie
- Process Research and Development, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | | | - Erik L Regalado
- Analytical Research and Development, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| |
Collapse
|
6
|
Juliano BR, Keating JW, Li HW, Anders AG, Xie Z, Ruotolo BT. Development of an Automated, High-Throughput Methodology for Native Mass Spectrometry and Collision-Induced Unfolding. Anal Chem 2023; 95:16717-16724. [PMID: 37924308 PMCID: PMC11081713 DOI: 10.1021/acs.analchem.3c03788] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2023]
Abstract
Native ion mobility mass spectrometry (nIM-MS) has emerged as a useful technology for the rapid evaluation of biomolecular structures. When combined with collisional activation in a collision-induced unfolding (CIU) experiment, nIM-MS experimentation can be leveraged to gain greater insight into biomolecular conformation and stability. However, nIM-MS and CIU remain throughput limited due to nonautomated sample preparation and introduction. Here, we explore the use of a RapidFire robotic sample handling system to develop an automated, high-throughput methodology for nMS and CIU. We describe native RapidFire-MS (nRapidFire-MS) capable of performing online desalting and sample introduction in as little as 10 s per sample. When combined with CIU, our nRapidFire-MS approach can be used to collect CIU fingerprints in 30 s following desalting by using size exclusion chromatography cartridges. When compared to nMS and CIU data collected using standard approaches, ion signals recorded by nRapidFire-MS exhibit identical ion collision cross sections, indicating that the same conformational populations are tracked by the two approaches. Our data further suggest that nRapidFire-MS can be extended to study a variety of biomolecular classes, including proteins and protein complexes ranging from 5 to 300 kDa and oligonucleotides. Furthermore, nRapidFire-MS data acquired for biotherapeutics suggest that nRapidFire-MS has the potential to enable high-throughput nMS analyses of biopharmaceutical samples. We conclude by discussing the potential of nRapidFire-MS for enabling the development of future CIU assays capable of catalyzing breakthroughs in protein engineering, inhibitor discovery, and formulation development for biotherapeutics.
Collapse
Affiliation(s)
- Brock R Juliano
- Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Joseph W Keating
- Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Henry W Li
- Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Anna G Anders
- Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Zhuoer Xie
- Attribute Sciences, Process Development, Amgen, Thousand Oaks, California 91320, United States
| | - Brandon T Ruotolo
- Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States
| |
Collapse
|
7
|
Juliano BR, Ruotolo BT. Collision Induced Unfolding Enables the Quantitation of Isomass Biotherapeutics in Complex Biological Matrices. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023; 34:2350-2357. [PMID: 37584234 PMCID: PMC11081006 DOI: 10.1021/jasms.3c00234] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/17/2023]
Abstract
Quantitative mass spectrometry has been widely used to evaluate the concentrations of molecules within a variety of biological matrices. Typically, such quantitative mass spectrometry analyses are predicated upon the production of mass-resolved precursor or fragment ions, leading to challenges surrounding the quantification of isomeric or conformationally distinct analytes. As such, new approaches are required for the label-free quantification of isomass proteins. Native ion-mobility MS (nIM-MS) in combination with collision induced unfolding (CIU) is a potentially enabling approach for such quantitative mass spectrometry methods as the technique can rapidly separate and detect many biomacromolecule isoforms. CIU uses collisional activation to capture the unfolding trajectory of ions in the gas phase, producing different intermediate structures that can be leveraged to distinguish protein structures that exhibit identical sizes at lower energies. Here we describe the deployment of quantitative CIU methodology to measure the concentrations of isomass pairs of biotherapeutics and sequence homologues in both standard and biological matrices. Our results cover three antibody pairs and include examples of mixed therapies where multiple biologics are commonly provided to patients. In all cases, CIU enables the production of resolved features for each antibody mixture probed, producing calibration curves with correlation coefficients ranging from 0.92 to 0.99, limits of detection ranging from 300 to 5000 nM and sensitivities ranging from 8.7 × 10-5 nM-1 to 6 × 10-3 μM-1. We conclude our report by projecting the future utility of CIU-enabled quantitative MS methods.
Collapse
Affiliation(s)
- Brock R Juliano
- Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Brandon T Ruotolo
- Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States
| |
Collapse
|
8
|
Murray BE, Penabad LI, Kennedy RT. Advances in coupling droplet microfluidics to mass spectrometry. Curr Opin Biotechnol 2023; 82:102962. [PMID: 37336080 DOI: 10.1016/j.copbio.2023.102962] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 05/12/2023] [Accepted: 05/23/2023] [Indexed: 06/21/2023]
Abstract
Droplet microfluidics enables development of workflows with low sample consumption and high throughput. Fluorescence-based assays are most used with droplet microfluidics; however, the requirement of a fluorescent reporter restricts applicability of this approach. The coupling of droplets to mass spectrometry (MS) has enabled selective assays on complex mixtures to broaden the analyte scope. Droplet microfluidics has been interfaced to MS via electrospray ionization (ESI) and matrix-assisted laser desorption ionization (MALDI). The works reviewed herein outline the development of this nascent field as well as initial exploration of its application in biotechnology and bioanalysis, including synthetic biology, reaction development, and in vivo sensing.
Collapse
Affiliation(s)
- Bridget E Murray
- Department of Chemistry, University of Michigan, 930 N. University Ave, Ann Arbor, MI 48109-1055, USA
| | - Laura I Penabad
- Department of Chemistry, University of Michigan, 930 N. University Ave, Ann Arbor, MI 48109-1055, USA
| | - Robert T Kennedy
- Department of Chemistry, University of Michigan, 930 N. University Ave, Ann Arbor, MI 48109-1055, USA.
| |
Collapse
|
9
|
Fiorentino F, Rotili D, Mai A. Native mass spectrometry-directed drug discovery: Recent advances in investigating protein function and modulation. Drug Discov Today 2023; 28:103548. [PMID: 36871843 DOI: 10.1016/j.drudis.2023.103548] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2022] [Revised: 02/15/2023] [Accepted: 02/28/2023] [Indexed: 03/07/2023]
Abstract
Native mass spectrometry (nMS) is a biophysical method for studying protein complexes and can provide insights into subunit stoichiometry and composition, protein-ligand, and protein-protein interactions (PPIs). These analyses are made possible by preserving non-covalent interactions in the gas phase, thereby allowing the analysis of proteins in their native state. Consequently, nMS has been increasingly applied in early drug discovery campaigns for the characterization of protein-drug interactions and the evaluation of PPI modulators. Here, we discuss recent developments in nMS-directed drug discovery and provide a timely perspective on the possible applications of this technology in drug discovery.
Collapse
Affiliation(s)
- Francesco Fiorentino
- Department of Drug Chemistry and Technologies, Sapienza University of Rome, Piazzale Aldo Moro 5, 00185 Rome, Italy.
| | - Dante Rotili
- Department of Drug Chemistry and Technologies, Sapienza University of Rome, Piazzale Aldo Moro 5, 00185 Rome, Italy.
| | - Antonello Mai
- Department of Drug Chemistry and Technologies, Sapienza University of Rome, Piazzale Aldo Moro 5, 00185 Rome, Italy; Pasteur Institute, Cenci-Bolognetti Foundation, Sapienza University of Rome, Piazzale Aldo Moro 5, 00185 Rome, Italy
| |
Collapse
|