1
|
Gao L, Tian Y, Hussain A, Guan Y, Xu G. Recent developments and challenges in resistance-based hydrogen gas sensors based on metal oxide semiconductors. Anal Bioanal Chem 2024; 416:3697-3715. [PMID: 38443743 DOI: 10.1007/s00216-024-05213-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2023] [Revised: 02/15/2024] [Accepted: 02/19/2024] [Indexed: 03/07/2024]
Abstract
In recent years, the energy crisis has made the world realize the importance and need for green energy. Hydrogen safety has always been a primary issue that needs to be addressed for the application and large-scale commercialization of hydrogen energy, and precise and rapid hydrogen gas sensing technology and equipment are important prerequisites for ensuring hydrogen safety. Based on metal oxide semiconductors (MOS), resistive hydrogen gas sensors (HGS) offer advantages, such as low cost, low power consumption, and high sensitivity. They are also easy to test, integrate, and suitable for detecting low concentrations of hydrogen gas in ambient air. Therefore, they are considered one of the most promising HGS. This article provides a comprehensive review of the surface reaction mechanisms and recent research progress in optimizing the gas sensing performance of MOS-based resistive hydrogen gas sensors (MOS-R-HGS). Particularly, the advancements in metal-assisted or doped MOS, mixed metal oxide (MO)-MOS composites, MOS-carbon composites, and metal-organic framework-derived (MOF)-MOS composites are extensively summarized. Finally, the future research directions and possibilities in this field are discussed.
Collapse
Affiliation(s)
- Lili Gao
- School of Materials Science and Engineering, Shenyang Jianzhu University, Shenyang, 110168, China.
| | - Ye Tian
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun, 130022, People's Republic of China.
| | - Altaf Hussain
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun, 130022, People's Republic of China
- School of Applied Chemistry and Engineering, University of Science and Technology of China, No. 96 Jinzhai Road, Hefei, Anhui, 230026, People's Republic of China
| | - Yiran Guan
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun, 130022, People's Republic of China
| | - Guobao Xu
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun, 130022, People's Republic of China.
- School of Applied Chemistry and Engineering, University of Science and Technology of China, No. 96 Jinzhai Road, Hefei, Anhui, 230026, People's Republic of China.
| |
Collapse
|
2
|
Bushira FA, Hussain A, Wang P, Li H, Zheng L, Gao Z, Dong H, Jin Y. Boosting Electrochemiluminescence Performance of a Dual-Active Site Iron Single-Atom Catalyst-Based Luminol-Dissolved Oxygen System via Plasmon-Induced Hot Holes. Anal Chem 2024; 96:9704-9712. [PMID: 38819721 DOI: 10.1021/acs.analchem.4c01744] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2024]
Abstract
Due to the commonly low content of biomarkers in diseases, increasing the sensitivity of electrochemiluminescence (ECL) systems is of great significance for in vitro ECL diagnosis and biodetection. Although dissolved O2 (DO) has recently been considered superior to H2O2 as a coreactant in the most widely used luminol ECL systems owing to its improved stability and less biotoxicity, it still has unsatisfactory ECL performance because of its ultralow reactivity. In this study, an effective plasmonic luminol-DO ECL system has been developed by complexing luminol-capped Ag nanoparticles (AgNPs) with plasma-treated Fe single-atom catalysts (Fe-SACs) embedded in graphitic carbon nitride (g-CN) (pFe-g-CN). Under optimal conditions, the performance of the resulting ECL system could be markedly increased up to 1300-fold compared to the traditional luminol-DO system. Further investigations revealed that duple binding sites of pFe-g-CN and plasmonically induced hot holes that disseminated from AgNPs to g-CN surfaces lead to facilitate significantly the luminous reaction process of the system. The proposed luminol-DO ECL system was further employed for the stable and ultrasensitive detection of prostate-specific antigen in a wide linear range of 1.0 fg/mL to 1 μg/mL, with a pretty low limit of detection of 0.183 fg/mL.
Collapse
Affiliation(s)
- Fuad Abduro Bushira
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, National Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen 518060, China
| | - Altaf Hussain
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, P. R. China
| | - Ping Wang
- Key Laboratory of Preparation and Applications of Environment Friendly Materials of the Ministry of Education, College of Chemistry, Jilin Normal University, Changchun 130103, China
| | - Haijuan Li
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, P. R. China
| | - Lirong Zheng
- Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
| | - Zhuangqiang Gao
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, National Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen 518060, China
| | - Haifeng Dong
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, National Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen 518060, China
| | - Yongdong Jin
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, National Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen 518060, China
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, P. R. China
| |
Collapse
|
3
|
Li M, Zhang L, Liu W, Jin Y, Li B. Facile Estimation of Surface Oxygen Vacancies in Co 3O 4 Catalysts with a Colorimetric Method. Anal Chem 2024; 96:8999-9006. [PMID: 38758012 DOI: 10.1021/acs.analchem.4c00242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/18/2024]
Abstract
Oxygen vacancy (Ov) is known to act as an active center of the metal oxide. Quantification of surface Ov is vital for understanding the quantitative structure-activity relationship. Facile quantification characterization of surface Ov is highly desirable but still challenging. In this study, we presented a simple colorimetric method for rapidly quantifying surface Ov. As an example of metal oxide nanoparticles, Co3O4 was used to catalyze the 3,3',5,5'-tetramethylbenzidine (TMB)-H2O2 colorimetric reaction. It was found that the absorbance of the TMB-H2O2 system was dependent on the surface Ov amount in Co3O4. The investigation of the mechanism showed that the Ov-dependent absorbance would be attributed to the activity of surface Ov to easily adsorb and dissociate H2O2 into a hydroxyl radical (•OH). The absorbance signal of the TMB-H2O2 system acted as a probe to estimate the surface Ov. This colorimetric measurement could be completed in less than 20 min. The Ov concentrations obtained by the proposed colorimetric method matched well with those obtained by X-ray photoelectron spectroscopy. This method does not require any complex operation and expensive equipment and can be performed in any ordinary chemical laboratory. So, this colorimetric method is expected to become an alternative approach for quantifying the surface Ov in metal oxide nanoparticles. This method will provide essential insights into the rational design and application of Ov.
Collapse
Affiliation(s)
- Mei Li
- Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education; Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry & Chemical Engineering, Shaanxi Normal University, Xi'an 710062, China
| | - Ling Zhang
- Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education; Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry & Chemical Engineering, Shaanxi Normal University, Xi'an 710062, China
| | - Wei Liu
- Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education; Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry & Chemical Engineering, Shaanxi Normal University, Xi'an 710062, China
| | - Yan Jin
- Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education; Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry & Chemical Engineering, Shaanxi Normal University, Xi'an 710062, China
| | - Baoxin Li
- Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education; Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry & Chemical Engineering, Shaanxi Normal University, Xi'an 710062, China
| |
Collapse
|
4
|
Hussain A, Suleiman MY, Liu H, Xia S, Eticha T, Guan Y, Chen W, Xu G. Highly Sensitive Diethylamine Detection at Room Temperature Using g-C 3N 4 Nanosheets Decorated with CuO Hollow Polyhedral Structures. Anal Chem 2024; 96:8965-8972. [PMID: 38764427 DOI: 10.1021/acs.analchem.3c05968] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/21/2024]
Abstract
Chemiresistive-based metal oxide semiconductor (MOS) gas sensors are widely used in gas sensing due to their advantageous properties. Graphitic carbon nitride (g-C3N4) and metal oxide heterostructure materials can improve charge transport properties, selectivity, and sensitivity in MOS gas sensor materials. Herein, for the first time, CuO hollow polyhedral structures (HPSs) were synthesized via a hydrothermal technique and annealed at different temperatures, with the 400 °C annealed (CuO-400 HPSs) demonstrating remarkable sensing capabilities for diethylamine (DEA) gas at room temperature (RT). The x-g-C3N4 nanosheets were decorated with CuO HPSs in varying amounts (x = 0.8, 1.8, 2.1, and 3.1 wt %) and then annealed at 400 °C for x-g-C3N4-CuO-400 hollow polyhedral heterostructures (HPHSs). Indeed, among the synthesized samples, the 1.8%-g-C3N4-CuO-400 HPHSs have a higher sensitivity to DEA (resistance change in gas (Rg) and air (Ra); Rg/Ra= 65 @ 20 ppm), a low detection limit (Rg/Ra= 6 @ 500 ppb), wide dynamic response (Rg/Ra= 190 @ 80 ppm), strong stability (30 days), and 21.6 times higher sensitivity than pure CuO at RT toward 20 ppm of DEA. The exceptional gas-sensing behavior can be attributed to various factors, including controlled annealing conditions that result in the formation of well-defined structures and greater porosity, efficient charge transfer properties resulting from an optimized ratio of g-C3N4 to CuO in HPHSs, an abundance of defects, unsaturated Cu sites, and synergistic effects. The study presents a universal strategy for generating sensitive and selective g-C3N4-based composite materials for low-temperature gas sensors.
Collapse
Affiliation(s)
- Altaf Hussain
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, P. R. China
- School of Applied Chemistry and Engineering, University of Science and Technology of China, No. 96 Jinzhai Road, Hefei, Anhui 230026, P. R. China
| | - Mohammed Y Suleiman
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, P. R. China
- School of Applied Chemistry and Engineering, University of Science and Technology of China, No. 96 Jinzhai Road, Hefei, Anhui 230026, P. R. China
| | - Hongzhan Liu
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, P. R. China
- School of Applied Chemistry and Engineering, University of Science and Technology of China, No. 96 Jinzhai Road, Hefei, Anhui 230026, P. R. China
| | - Shiyu Xia
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, P. R. China
- School of Applied Chemistry and Engineering, University of Science and Technology of China, No. 96 Jinzhai Road, Hefei, Anhui 230026, P. R. China
| | - Tadele Eticha
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, P. R. China
- School of Applied Chemistry and Engineering, University of Science and Technology of China, No. 96 Jinzhai Road, Hefei, Anhui 230026, P. R. China
| | - Yiran Guan
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, P. R. China
| | - Wei Chen
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, P. R. China
- School of Applied Chemistry and Engineering, University of Science and Technology of China, No. 96 Jinzhai Road, Hefei, Anhui 230026, P. R. China
- School of Chemistry and Pharmaceutical Sciences, Guangxi Normal University, Guilin, Guangxi 541004, China
| | - Guobao Xu
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, P. R. China
- School of Applied Chemistry and Engineering, University of Science and Technology of China, No. 96 Jinzhai Road, Hefei, Anhui 230026, P. R. China
| |
Collapse
|
5
|
Kumar P, Chandel M, Kataria S, Swami K, Kaur K, Sahu BK, Dadhich A, Urkude RR, Subaharan K, Koratkar N, Shanmugam V. Handheld Crop Pest Sensor Using Binary Catalyst-Loaded Nano-SnO 2 Particles for Oxidative Signal Amplification. ACS Sens 2024; 9:81-91. [PMID: 38113168 DOI: 10.1021/acssensors.3c01669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2023]
Abstract
In agriculture, pest management is a major challenge. Crop releases volatiles in response to the pest; hence, sensing these volatile signals at a very early stage will ease pest management. Here, binary catalyst-loaded SnO2 nanoparticles of <5 nm were synthesized for the repeated capture and oxidation of the signature volatile and its products to amplify the chemoresistive signal to detect concentrations as low as ≈120 ppb. The sensitivity may be due to the presence of the elements in the Sn-Fe-Pt bond evidenced by extended X-ray absorption fine-structure spectroscopy (EXAFS) that captures and oxidize the volatile without escaping. This strong catalyst may oxidize nontarget volatiles and can cause false signals; hence, a molecular sieve filter has been coupled to ensure high selectivity for the detection ofTuta absolutainfestation in tomato. Finally, with the support of a mobile power bank, the optimized sensor has been assembled into a lightweight handheld device.
Collapse
Affiliation(s)
- Prem Kumar
- Institute of Nano Science and Technology, Mohali 140306, India
| | - Mahima Chandel
- Institute of Nano Science and Technology, Mohali 140306, India
| | - Sarita Kataria
- Institute of Nano Science and Technology, Mohali 140306, India
| | - Kanchan Swami
- Institute of Nano Science and Technology, Mohali 140306, India
| | - Kamaljit Kaur
- Institute of Nano Science and Technology, Mohali 140306, India
| | | | - Ankita Dadhich
- Institute of Nano Science and Technology, Mohali 140306, India
| | - Rajashri R Urkude
- Accelerator Physics & Synchrotrons Utilization Division, Raja Ramanna Centre for Advanced Technology, Indore 452013, India
| | - Kesavan Subaharan
- ICAR - National Bureau of Agricultural Insect Resources, Bangalore 560064, India
| | - Nikhil Koratkar
- Materials Science Department, Rensselaer Polytechnic Institute, Troy, New York 12180, United States
| | | |
Collapse
|
6
|
Lei J, Zhang L, Li M, Liu W, Jin Y, Li B. Surface Oxygen Vacancy-Rich Co 3O 4 Nanowires as an Effective Catalyst of Luminol-H 2O 2 Chemiluminescence for Sensitive Immunoassay. Anal Chem 2023; 95:17937-17944. [PMID: 37991222 DOI: 10.1021/acs.analchem.3c04409] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2023]
Abstract
Oxygen vacancy is one intrinsic defect in metal oxide materials. Interestingly, we herein found that the surface oxygen vacancy can significantly enhance the catalytic activity of Co3O4 nanowires in the luminol-H2O2 chemiluminescence (CL) reaction. 0.1 ng/mL Co3O4 nanowires containing 51.3% surface oxygen vacancies possessed ca. 2.5-fold catalytic activity of free Co2+ (the best metal ionic catalyst for the luminol-H2O2 CL reaction). The superior catalytic efficiency is attributed to the enhanced adsorption of H2O2 by surface oxygen vacancies, which in turn accelerates the cleavage of O-O bonds and generates •OH radicals. More importantly, the surface oxygen vacancy-rich Co3O4 nanowires retained about 90% catalytic activity after modification with antibodies. The surface oxygen vacancy-rich Co3O4 nanowires were used to label the secondary antibody, and one sandwich-type CL immunoassay of carcinoembryonic antigen was established. The detection limit was 0.3 ng/mL with a linear range of 1-10 ng/mL. This proof-of-concept work proves that surface oxygen vacancy-rich Co3O4 nanowires are suitable for labeling biomolecules in CL bioanalysis and biosensing.
Collapse
Affiliation(s)
- Jing Lei
- Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education, Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry & Chemical Engineering, Shaanxi Normal University, Xi'an 710062, China
| | - Ling Zhang
- Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education, Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry & Chemical Engineering, Shaanxi Normal University, Xi'an 710062, China
| | - Mei Li
- Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education, Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry & Chemical Engineering, Shaanxi Normal University, Xi'an 710062, China
| | - Wei Liu
- Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education, Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry & Chemical Engineering, Shaanxi Normal University, Xi'an 710062, China
| | - Yan Jin
- Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education, Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry & Chemical Engineering, Shaanxi Normal University, Xi'an 710062, China
| | - Baoxin Li
- Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education, Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry & Chemical Engineering, Shaanxi Normal University, Xi'an 710062, China
| |
Collapse
|
7
|
Hussain A, Lou B, Bushira FA, Xia S, Liu F, Guan Y, Chen W, Xu G. Ultrafast Response and High Selectivity of Diethylamine Gas Sensors at Room Temperature Using MOF-Derived 1D CuO Nano-Ellipsoids. Anal Chem 2023; 95:17568-17576. [PMID: 37988575 DOI: 10.1021/acs.analchem.3c02890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2023]
Abstract
Environmental and health monitoring requires low-cost, high-performance diethylamine (DEA) sensors. Materials based on metal-organic frameworks (MOFs) can detect hazardous gases due to their large specific surface area, many metal sites, unsaturated sites, functional connectivity, and easy calcination to remove the scaffold. However, developing facile materials with high sensitivity and selectivity in harsh environments for accurate DEA detection at a low detection limit (LOD) at room temperature (RT) is challenging. In this study, p-type semiconducting porous CuOx sensing materials were synthesized using a simple solvothermal process and annealed in an argon atmosphere at three different temperatures (x = 400, 600, and 800 °C). Significant variations in particle size, specific area, crystallite size, and shape were noticed when the annealing temperature was elevated. Cu-MIL-53 annealed at 400 °C (CuO-400) has a typical nanoellipsoid (NEs) shape with a length of 61.5 nm and a diameter of 33.2 nm. Surprisingly, CuO-400 NEs showed an excellent response to DEA with an ultra-LOD (Rg/Ra = 7.3 @ 100 ppb, 55% relative humidity), excellent selectivity and sensitivity (Rg/Ra = 236 @ 15 ppm), exceptional long-term stability and repeatability, and a fast response/recovery period at RT, outperforming most previously reported materials. CuO-400 NEs have outstanding gas-sensing characteristics due to their high porosity, 1D nanostructure, unsaturated Cu sites (Cu+ and Cu2+), large specific surface area, and numerous oxygen vacancies. This study presents a generic approach to produce future CuO derived from Cu-MOFs-sensitive materials, revealing new insights into the design of effective sensors for environmental monitoring at RT.
Collapse
Affiliation(s)
- Altaf Hussain
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, P. R. China
- University of Science and Technology of China, No. 96 Jinzhai Road, Hefei 230026, Anhui, P. R. China
| | - Baohua Lou
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, P. R. China
- University of Science and Technology of China, No. 96 Jinzhai Road, Hefei 230026, Anhui, P. R. China
| | - Fuad Abduro Bushira
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, P. R. China
- University of Science and Technology of China, No. 96 Jinzhai Road, Hefei 230026, Anhui, P. R. China
| | - Shiyu Xia
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, P. R. China
- University of Science and Technology of China, No. 96 Jinzhai Road, Hefei 230026, Anhui, P. R. China
| | - Fangshuo Liu
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, P. R. China
- University of Science and Technology of China, No. 96 Jinzhai Road, Hefei 230026, Anhui, P. R. China
| | - Yiran Guan
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, P. R. China
- University of Science and Technology of China, No. 96 Jinzhai Road, Hefei 230026, Anhui, P. R. China
| | - Wei Chen
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, P. R. China
- University of Science and Technology of China, No. 96 Jinzhai Road, Hefei 230026, Anhui, P. R. China
- School of Chemistry and Pharmaceutical Sciences, Guangxi Normal University, Guilin 541004, Guangxi, P. R. China
| | - Guobao Xu
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, P. R. China
- University of Science and Technology of China, No. 96 Jinzhai Road, Hefei 230026, Anhui, P. R. China
| |
Collapse
|