Isokawa M, Nakanishi K, Kanamori T, Sekiguchi T, Funatsu T, Shoji S, Tsunoda M. Pillar Array Mixer for Postcolumn Derivatization Integrated into Liquid Chromatography-Based Microfluidic Device. Anal Chem 2024; 96:11002-11008. [PMID: 38870183 DOI: 10.1021/acs.analchem.4c01669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2024]
Abstract
The chemical derivatization of target analytes can enhance the sensitivity and selectivity of separation-based methods for metabolite analysis using microfluidic devices. However, the development of chromatography-based microfluidic devices with integrated derivatization units is challenging. In this study, a novel derivatization unit with a pillar array (PA)-based mixing channel was developed for postcolumn derivatization during on-chip liquid chromatography (LC). The PA mixer enhanced mixing between the derivatization reagents and analytes in the transverse direction, while preventing analyte dispersion in the flow direction. After the concept was confirmed using computational fluid dynamics analysis, microfluidic devices with a LC column and PA mixer were fabricated on a 20 × 20 mm silicon plate. Fluid experiments were performed using a PA mixer with a pillar size of 5 or 10 μm or a hollow-channel mixer, which revealed that the PA mixer enhanced transverse mixing without increasing the width of the analyte peak. Moreover, the developed device enabled the analysis of three amino acids within 40 s by separation via hydrophilic interaction chromatography followed by postcolumn fluorogenic derivatization with naphthalene-2,3-dicarboxaldehyde and fluorescence detection. Our results demonstrate the potential of integrated derivatization units for the development of micrototal analysis systems for use in bioanalysis.
Collapse
Affiliation(s)
- Muneki Isokawa
- Graduate School of Pharmaceutical Sciences, The University of Tokyo, Tokyo 113-0033, Japan
| | - Kanki Nakanishi
- Department of Nanoscience and Nanoengineering, Waseda University, Tokyo 169-8555, Japan
| | - Takahiro Kanamori
- Graduate School of Pharmaceutical Sciences, The University of Tokyo, Tokyo 113-0033, Japan
| | - Tetsushi Sekiguchi
- Department of Nanoscience and Nanoengineering, Waseda University, Tokyo 169-8555, Japan
| | - Takashi Funatsu
- Graduate School of Pharmaceutical Sciences, The University of Tokyo, Tokyo 113-0033, Japan
| | - Shuichi Shoji
- Department of Nanoscience and Nanoengineering, Waseda University, Tokyo 169-8555, Japan
| | - Makoto Tsunoda
- Graduate School of Pharmaceutical Sciences, The University of Tokyo, Tokyo 113-0033, Japan
| |
Collapse
|
2
|
Girel S, Meister I, Glauser G, Rudaz S. Hyphenation of microflow chromatography with electrospray ionization mass spectrometry for bioanalytical applications focusing on low molecular weight compounds: A tutorial review. MASS SPECTROMETRY REVIEWS 2024. [PMID: 38952056 DOI: 10.1002/mas.21898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2024] [Revised: 06/10/2024] [Accepted: 06/20/2024] [Indexed: 07/03/2024]
Abstract
Benefits of miniaturized chromatography with various detection modes, such as increased sensitivity, chromatographic efficiency, and speed, were recognized nearly 50 years ago. Over the past two decades, this approach has experienced rapid growth, driven by the emergence of mass spectrometry applications serving -omics sciences and the need for analyzing minute volumes of precious samples with ever higher sensitivity. While nanoscale liquid chromatography (flow rates <1 μL/min) has gained widespread recognition in proteomics, the adoption of microscale setups (flow rates ranging from 1 to 100 μL/min) for low molecular weight compound applications, including metabolomics, has been surprisingly slow, despite the inherent advantages of the approach. Highly heterogeneous matrices and chemical structures accompanied by a relative lack of options for both selective sample preparation and user-friendly equipment are usually reported as major hindrances. To facilitate the wider implementation of microscale analyses, we present here a comprehensive tutorial encompassing important theoretical and practical considerations. We provide fundamental principles in micro-chromatography and guide the reader through the main elements of a microflow workflow, from LC pumps to ionization devices. Finally, based on both our literature overview and experience, illustrated by some in-house data, we highlight the critical importance of the ionization source design and its careful optimization to achieve significant sensitivity improvement.
Collapse
Affiliation(s)
- Sergey Girel
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland
| | - Isabel Meister
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland
- Swiss Center of Applied Human Toxicology (SCAHT), Basel, Switzerland
| | - Gaetan Glauser
- Neuchâtel Platform of Analytical Chemistry, University of Neuchâtel, Neuchâtel, Switzerland
| | - Serge Rudaz
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland
- Swiss Center of Applied Human Toxicology (SCAHT), Basel, Switzerland
| |
Collapse
|
3
|
Blumberg LM. The best structures of LC columns-A theoretical perspective. J Chromatogr A 2024; 1721:464848. [PMID: 38569299 DOI: 10.1016/j.chroma.2024.464848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2024] [Revised: 03/23/2024] [Accepted: 03/25/2024] [Indexed: 04/05/2024]
Abstract
The largest peak capacity (n) that LC analysis can generate in isocratic or gradient elution analysis of a given sample in a given time at a given pressure is proportional to the quality factor (qmax) of its column structure. In this study, the multi-channel structures with open pseudo-planar channels (OPPC) and open circular channels (OCC) where compared with PC2 - a typical core-shell column packed with 2 μm particles. These columns have qmax of 1.27, 1.17 and 0.41, respectively. The former two qmax are the highest among all known column structures - about 3 times higher than qmax of PC2. This means that the OPPC and OCC can generate about 3 times higher n compared to what a PC2 can in the same analysis time (tanal) at the same pressure, or they require about 81 times shorter tanal (81 is the 4th power of 3) to generate the same n as a PC2 can at the same pressure. However, while PC2 is a commercially available column, there are substantial challenges in manufacturing the OPPC and OCC that can compete with PC2 in practical applications. In order to be competitive with PC2, the OPPC and OCC should have sub-1μm characteristic dimensions (e.g., the inter-pillar distance, g, in OPPC-based pillar array columns, internal diameters of OCC). Thus, in order to compete with PC2 in one scenario, an OPPC requires g ≤ 0.14 μm. Additionally, to be competitive with PC2, OPPC and OCC should be able to sustain the same high pressure. Highlighting the challenges of their design and manufacturing might help to develop the manufacturable columns substantially superior to the packed ones.
Collapse
|
4
|
Anderson BG, Hancock TA, Kennedy RT. Preparation of high-efficiency HILIC capillary columns utilizing slurry packing at 2100 bar. J Chromatogr A 2024; 1722:464856. [PMID: 38579610 DOI: 10.1016/j.chroma.2024.464856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Revised: 03/26/2024] [Accepted: 03/29/2024] [Indexed: 04/07/2024]
Abstract
Complex mixture analysis requires high-efficiency chromatography columns. Although reversed phase liquid chromatography (RPLC) is the dominant approach for such mixtures, hydrophilic interaction liquid chromatography (HILIC) is an important complement to RPLC by enabling the separation of polar compounds. Chromatography theory predicts that small particles and long columns will yield high efficiency; however, little work has been done to prepare HILIC columns longer than 25 cm packed with sub-2 μm particles. In this work, we tested the slurry packing of 75 cm long HILIC columns with 1.7 μm bridged-ethyl-hybrid amide HILIC particles at 2,100 bar (30,000 PSI). Acetonitrile, methanol, acetone, and water were tested as slurry solvents, with acetonitrile providing the best columns. Slurry concentrations of 50-200 mg/mL were assessed, and while 50-150 mg/mL provided comparable results, the 150 mg/mL columns provided the shortest packing times (9 min). Columns prepared using 150 mg/mL slurries in acetonitrile yielded a reduced minimum plate height (hmin) of 3.3 and an efficiency of 120,000 theoretical plates for acenaphthene, an unretained solute. Para-toluenesulfonic acid produced the lowest hmin of 1.9 and the highest efficiency of 210,000 theoretical plates. These results identify conditions for producing high-efficiency HILIC columns with potential applications to complex mixture analysis.
Collapse
Affiliation(s)
- Brady G Anderson
- Department of Chemistry, University of Michigan, Ann Arbor, MI 48109, United States
| | - Tate A Hancock
- Department of Chemistry, University of Michigan, Ann Arbor, MI 48109, United States
| | - Robert T Kennedy
- Department of Chemistry, University of Michigan, Ann Arbor, MI 48109, United States; Department of Pharmacology, University of Michigan, Ann Arbor, MI 48109, United States.
| |
Collapse
|
5
|
Tsai WH, Su CK. 4D-Printed Elution-Peak-Guided Dual-Responsive Monolithic Packing for the Solid-Phase Extraction of Metal Ions. Anal Chem 2024; 96:4469-4478. [PMID: 38380612 PMCID: PMC10955517 DOI: 10.1021/acs.analchem.3c04961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 02/06/2024] [Accepted: 02/08/2024] [Indexed: 02/22/2024]
Abstract
Four-dimensional printing (4DP) technologies are revolutionizing the fabrication of stimuli-responsive devices. To advance the analytical performance of conventional solid-phase extraction (SPE) devices using 4DP technology, in this study, we employed N-isopropylacrylamide (NIPAM)-incorporated photocurable resins and digital light processing three-dimensional printing to fabricate an SPE column with a [H+]/temperature dual-responsive monolithic packing stacked as interlacing cuboids to extract Mn, Co, Ni, Cu, Zn, Cd, and Pb ions. When these metal ions were eluted using 0.5% HNO3 solution as the eluent at a temperature below the lower critical solution temperature of polyNIPAM, the monolithic packing swelled owing to its hydrophilic/hydrophobic transition and electrostatic repulsion among the protonated units of polyNIPAM. These effects resulted in smaller interstitial volumes among these interlacing cuboids and improvements in the elution peak profiles of the metal ions, which, in turn, demonstrated the reduced method detection limits (MDLs; range, 0.2-7.2 ng L-1) during analysis using inductively coupled plasma mass spectrometry. We studied the effects of optimizing the elution peak profiles of the metal ions on the analytical performance of this method and validated its reliability and applicability by analyzing the metal ions in reference materials (CASS-4, SLRS-5, 1643f, and Seronorm Trace Elements Urine L-2) and performing spike analyses of seawater, groundwater, river water, and human urine samples. Our results suggest that this 4D-printed elution-peak-guided dual-responsive monolithic packing enables lower MDLs when packed in an SPE column to facilitate the analyses of the metal ions in complex real samples.
Collapse
Affiliation(s)
- Wen-Hsiu Tsai
- Department of Chemistry, National Chung Hsing University, Taichung 402, Taiwan, R.O.C
| | - Cheng-Kuan Su
- Department of Chemistry, National Chung Hsing University, Taichung 402, Taiwan, R.O.C
| |
Collapse
|
6
|
Vankeerberghen B, Op de Beeck J, Desmet G. Column-Only Band Broadening in a Porous Shell Radially Elongated Pillar Array Column. Anal Chem 2024; 96:3618-3626. [PMID: 38350649 DOI: 10.1021/acs.analchem.3c05756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/15/2024]
Abstract
In the quest for better performing separation media for liquid chromatography, micropillar array columns have received great interest over the past years. While previous research was mainly focused around micropillar array columns (μPACs) filled with cylindrical pillars, this contribution discusses μPACs with rectangular pillars, which, for the first time, have been anodized and hence carry a mesoporous shell. We report on a series of on-chip measurements of the band broadening and flow permeability in a μPAC with very wide radially elongated pillars (3·75 μm) and with an interpillar distance (2 μm) between that of the first (2.5 μm) and second generation (1.25 μm) of cylindrical μPACs. Because of the extreme flow path tortuosity, this type of μPAC can produce very large plate numbers over a short distance. Despite the relatively large interpillar distance, we obtain Hmin = 0.26 μm for a nearly unretained component (phase retention factor, k' ≈ 0.24) and Hmin = 0.79 μm for a retained component with k' ≈ 3. The kinetic performance in terms of separation impedance (Ei = 19) is considerably improved compared to cylindrical pillar μPACs (Ei in range 40-50) and is in excellent agreement with the theoretical value for an open tubular channel with a rectangular cross-section (Ei = 18). This shows that rectangular μPACs can be represented as a parallel bundle of interconnected open-tubular channels.
Collapse
Affiliation(s)
- Bert Vankeerberghen
- Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussels, Belgium
| | - Jeff Op de Beeck
- Thermo Fisher Scientific, Technologiepark-Zwijnaarde 82, 9052 Gent, Belgium
| | - Gert Desmet
- Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussels, Belgium
| |
Collapse
|