1
|
Yang K, Wang R, Lu J, Wang J, Liao X, Wang C. A covalent organic framework nanosheet-nanochannel composite with signal amplification strategy for electrochemical enantioselective recognition. Talanta 2024; 277:126331. [PMID: 38823324 DOI: 10.1016/j.talanta.2024.126331] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2024] [Revised: 05/18/2024] [Accepted: 05/27/2024] [Indexed: 06/03/2024]
Abstract
Recognition and separation of chiral isomers are of great importance in both industrial and biological applications. However, owing to identical molecular formulas and chemical properties of enantiomers, signal transduction and amplification are still two major challenges in chiral sensing. In this study, we developed an enantioselective device by integrating chiral covalent organic framework nanosheets (CONs) with nanochannels for sensitive identification and quantification of enantiomers. Using 3,4-dihydroxyphenylalanine (DOPA) as the model analyte, the as-prepared chiral nanofluidic device exhibits a remarkable chiral recognition ability to l-DOPA than d-DOPA. More importantly, due to the chelation of DOPA with Fe3+ ions, it can efficiently block the ion transport through channel and shield the channel surface charge, which will amplify the difference in the electrochemical response of l-DOPA and d-DOPA. Therefore, a sensitive chiral recognition can be achieved using the present nanofluidic device coupled using electrochemical amplification strategy. Notably, using this method, an ultra-low concentration of l-DOPA (as low as 0.21 pM) can be facilely and successfully detected with a linear range of 1 pM-10 μM. This study provides a reliable and sensitive approach for achieving highly selective detection of chiral molecules.
Collapse
Affiliation(s)
- Kun Yang
- Jiangsu Key Laboratory of Biofunctional Materials, Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, Jiangsu Key Laboratory of New Power Batteries, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing, 210023, China
| | - Ruyi Wang
- Jiangsu Key Laboratory of Biofunctional Materials, Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, Jiangsu Key Laboratory of New Power Batteries, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing, 210023, China
| | - Junjian Lu
- Jiangsu Key Laboratory of Biofunctional Materials, Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, Jiangsu Key Laboratory of New Power Batteries, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing, 210023, China; Honors college, Nanjing Normal University, Nanjing, 210023, China
| | - Jin Wang
- Jiangsu Key Laboratory of Biofunctional Materials, Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, Jiangsu Key Laboratory of New Power Batteries, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing, 210023, China
| | - Xuewei Liao
- Jiangsu Key Laboratory of Biofunctional Materials, Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, Jiangsu Key Laboratory of New Power Batteries, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing, 210023, China; Analytical & Testing Center, Nanjing Normal University, Nanjing, 210023, China.
| | - Chen Wang
- Jiangsu Key Laboratory of Biofunctional Materials, Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, Jiangsu Key Laboratory of New Power Batteries, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing, 210023, China.
| |
Collapse
|
2
|
Burk RJ, Wahab MF, Armstrong DW. Influence of theoretical and semi-empirical peak models on the efficiency calculation in chiral chromatography. Talanta 2024; 277:126308. [PMID: 38820823 DOI: 10.1016/j.talanta.2024.126308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2024] [Revised: 05/13/2024] [Accepted: 05/20/2024] [Indexed: 06/02/2024]
Abstract
Height equivalent to theoretical plate (H) equations, such as the van Deemter or Knox-Saleem equations, and other efficiency vs. linear velocity equations (u), provide kinetic insights into chromatographic separations phenomena and column performance. In enantioselective separations, the peak shape of the two enantiomers can differ significantly and are often asymmetric. The peak efficiency calculations heavily impact these efficiency-flow profiles, leading to erroneous estimations of eddy diffusion, longitudinal diffusion, and mass transfer terms. In this work, new asymmetric peak functions are employed for modeling enantiomer peaks based on the Haarhoff-Van der Linde function, its generalized variant (GHVL), once Generalized Asymmetric Gaussian (AGN), and Twice Generalized Gaussian (TGN). The new models (AGN, TGN, and GHVL) incorporate higher statistical moments besides the zeroth, first, and second moments to account for two-sided asymmetry (fronting or tailing). The fit results are compared with the traditional efficiency calculation methods endorsed by official pharmacopeia and numerical estimation of moments from the raw data. Enantiomeric separations of ibuprofen and dl-homophenylalanine were chosen as probe molecules. The results demonstrate that non-linear least squares fitted functions provide better estimations of peak efficiency data even in the presence of high noise. In particular, the generalized models consistently offered the best quality fits for various peak shapes in chiral separations. Conversely, the half-height Gaussian method greatly overpredicted skewed peak efficiencies. This investigation reveals that the commonly held assumptions of peak shape and numerical integration of raw data are highly insufficient for chiral chromatography. The impact of asymmetry on plate height should not be overlooked when accurate data from efficiency-flow rate curves is derived. We advocate for the broader adoption of these new generalized peak (AGN, TGN, GHVL) models because they provide robustness at various SNRs that account for right or left asymmetry while accurately representing peak geometry.
Collapse
Affiliation(s)
- Ryan Jacob Burk
- Department of Chemistry & Biochemistry, University of Texas at Arlington, Texas, 76019, USA
| | - M Farooq Wahab
- Department of Chemistry & Biochemistry, University of Texas at Arlington, Texas, 76019, USA.
| | - Daniel W Armstrong
- Department of Chemistry & Biochemistry, University of Texas at Arlington, Texas, 76019, USA.
| |
Collapse
|
3
|
Ren S, Zhang X, Zhang R, Zhang H, Jiao D, Chang H. A microchip based Z-cell absorbance detector integrating micro-lenses and slits for portable liquid chromatography. J Chromatogr A 2024; 1730:465099. [PMID: 38901298 DOI: 10.1016/j.chroma.2024.465099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2024] [Revised: 06/11/2024] [Accepted: 06/14/2024] [Indexed: 06/22/2024]
Abstract
A miniaturized microchip-based absorbance detector was developed for portable high-performance liquid chromatography (HPLC) to test glycated hemoglobin (HbA1c). The microchip integrating a Z-shaped cell, two collimating micro-lenses and two ink-filled optical slits is small in size (30 mm × 15 mm × 7 mm). The Z-shaped cell has a cross-sectional size of 500 μm × 500 μm and a physical optical path length of 2 mm. Two collimating micro-lenses were inserted in empty grooves on both sides of the cell, one micro-lens for collimating the initial light and the other for focusing the transmitted light. Optical slits on each end of the cell were used to block the stray light. Therefore, this detector indicated a low stray light level (0.011 %) and noise level (2.5 × 10-4 AU). This detector was applied for the commercial HPLC system to detect HbA1c level, and showed a low limit of detection (0.5 μg/mL) and excellent repeatability (≤ 2.03 %). The sensitivity was enhanced by 3.4 times when the optical path length was increased from 0.5 mm to 2 mm and the stray light was blocked by optical slits. The miniaturized microchip-based absorbance detector developed shows a great potential for application in portable and compact HPLC.
Collapse
Affiliation(s)
- Shuang Ren
- Ministry of Education Key Laboratory of Micro/Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an 710072, China
| | - Xiaorui Zhang
- Ministry of Education Key Laboratory of Micro/Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an 710072, China
| | - Ruirong Zhang
- Ministry of Education Key Laboratory of Micro/Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an 710072, China.
| | - Hantian Zhang
- Ministry of Education Key Laboratory of Micro/Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an 710072, China
| | - Dezhao Jiao
- Ministry of Education Key Laboratory of Micro/Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an 710072, China
| | - Honglong Chang
- Ministry of Education Key Laboratory of Micro/Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an 710072, China.
| |
Collapse
|
4
|
Girel S, Meister I, Glauser G, Rudaz S. Hyphenation of microflow chromatography with electrospray ionization mass spectrometry for bioanalytical applications focusing on low molecular weight compounds: A tutorial review. MASS SPECTROMETRY REVIEWS 2024. [PMID: 38952056 DOI: 10.1002/mas.21898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2024] [Revised: 06/10/2024] [Accepted: 06/20/2024] [Indexed: 07/03/2024]
Abstract
Benefits of miniaturized chromatography with various detection modes, such as increased sensitivity, chromatographic efficiency, and speed, were recognized nearly 50 years ago. Over the past two decades, this approach has experienced rapid growth, driven by the emergence of mass spectrometry applications serving -omics sciences and the need for analyzing minute volumes of precious samples with ever higher sensitivity. While nanoscale liquid chromatography (flow rates <1 μL/min) has gained widespread recognition in proteomics, the adoption of microscale setups (flow rates ranging from 1 to 100 μL/min) for low molecular weight compound applications, including metabolomics, has been surprisingly slow, despite the inherent advantages of the approach. Highly heterogeneous matrices and chemical structures accompanied by a relative lack of options for both selective sample preparation and user-friendly equipment are usually reported as major hindrances. To facilitate the wider implementation of microscale analyses, we present here a comprehensive tutorial encompassing important theoretical and practical considerations. We provide fundamental principles in micro-chromatography and guide the reader through the main elements of a microflow workflow, from LC pumps to ionization devices. Finally, based on both our literature overview and experience, illustrated by some in-house data, we highlight the critical importance of the ionization source design and its careful optimization to achieve significant sensitivity improvement.
Collapse
Affiliation(s)
- Sergey Girel
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland
| | - Isabel Meister
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland
- Swiss Center of Applied Human Toxicology (SCAHT), Basel, Switzerland
| | - Gaetan Glauser
- Neuchâtel Platform of Analytical Chemistry, University of Neuchâtel, Neuchâtel, Switzerland
| | - Serge Rudaz
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland
- Swiss Center of Applied Human Toxicology (SCAHT), Basel, Switzerland
| |
Collapse
|
5
|
Tan L, Cai W, Wang F, Li J, Wu D, Kong Y. Postsynthetic Modification Strategy for Constructing Electrochemiluminescence-Active Chiral Covalent Organic Frameworks Performing Efficient Enantioselective Sensing. Anal Chem 2024; 96:3942-3950. [PMID: 38394220 DOI: 10.1021/acs.analchem.3c05887] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/25/2024]
Abstract
Electrochemiluminescence (ECL), integrating the characteristics of electrochemistry and fluorescence, has the advantages of high sensitivity and low background. However, only a few studies have been reported for enantioselective sensing based on the ECL-active platform because of the huge challenges in constructing tunable chiral ECL luminophores. Here, we developed a facile strategy to design and prepare ECL-active chiral covalent organic frameworks (COFs) Ph-triPy+-(R)-Ru(II) for enantioselective sensing. In such an artificial structure, the ionic skeleton of COFs was beneficial to the electron transfer on the working electrode surface and the chiral Ru-ligand was used as the chiral ECL-active luminophore. It was found that Ph-triPy+-(R)-Ru(II) coupled with sodium persulfate (Na2S2O8) as the coreactant exhibited obvious ECL signals. More importantly, a clear difference toward l- and d-enantiomers was observed in the response of the ECL intensity, resulting in a uniform recognition law. That is, for amino alcohols, d-enantiomers (1 mM) measured by Ph-triPy+-(R)-Ru(II) showed a higher ECL intensity compared with l-enantiomers. Differently, amino acids (1 mM) gave an inverse recognition phenomenon. The ECL intensity ratios between l- and d-enantiomers (1 mM) are in the range of 1.25-1.94 for serine, aspartic acid, glutamic acid, valine, leucine, leucinol, and valinol. What is more interesting is that the ECL intensity was closely related to the concentration of l-amino alcohols and d-amino acids, whereas their inverse configurations remained unchanged. In a word, the present concept demonstrates a feasible direction toward chiral ECL-active COFs and their potential for efficient enantioselective sensing.
Collapse
Affiliation(s)
- Lilan Tan
- Jiangsu Key Laboratory of Advanced Materials and Technology, School of Petrochemical Engineering, Changzhou University, Changzhou 213164, China
| | - Wenrong Cai
- Jiangsu Key Laboratory of Advanced Materials and Technology, School of Petrochemical Engineering, Changzhou University, Changzhou 213164, China
| | - Fangqin Wang
- Jiangsu Key Laboratory of Advanced Materials and Technology, School of Petrochemical Engineering, Changzhou University, Changzhou 213164, China
| | - Junyao Li
- Jiangsu Key Laboratory of Advanced Materials and Technology, School of Petrochemical Engineering, Changzhou University, Changzhou 213164, China
| | - Datong Wu
- Jiangsu Key Laboratory of Advanced Materials and Technology, School of Petrochemical Engineering, Changzhou University, Changzhou 213164, China
| | - Yong Kong
- Jiangsu Key Laboratory of Advanced Materials and Technology, School of Petrochemical Engineering, Changzhou University, Changzhou 213164, China
| |
Collapse
|
6
|
Aredes RS, Lima IDP, Faillace AP, Madriaga VGC, Lima TDM, Vaz FAS, Marques FFDC, Duarte LM. From capillaries to microchips, green electrophoretic features for enantiomeric separations: A decade review (2013-2022). Electrophoresis 2023; 44:1471-1518. [PMID: 37667860 DOI: 10.1002/elps.202200178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 06/28/2023] [Accepted: 07/12/2023] [Indexed: 09/06/2023]
Abstract
Enantioseparation by the electromigration-based method is well-established and widely discussed in the literature. Electrophoretic strategies have been used to baseline resolve complex enantiomeric mixtures, typically using a selector substance into the background electrolyte (BGE) from capillaries to microchips. Along with developing new materials/substances for enantioseparations, it is the concern about the green analytical chemistry (GAC) principles for method development and application. This review article brings a last decade's update on the publications involving enantioseparation by electrophoresis for capillary and microchip systems. It also brings a critical discussion on GAC principles and new green metrics in the context of developing an enantioseparation method. Chemical and green features of native and modified cyclodextrins are discussed. Still, given the employment of greener substances, ionic liquids and deep-eutectic solvents are highlighted, and some new selectors are proposed. For all the mentioned selectors, green features about their production, application, and disposal are considered. Sample preparation and BGE composition in GAC perspective, as well as greener derivatization possibilities, were also addressed. Therefore, one of the goals of this review is to aid the electrophoretic researchers to look where they have not.
Collapse
Affiliation(s)
- Rafaella S Aredes
- Programa, de Pós-Graduação em Química, Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, Niterói, Rio de Janeiro, Brazil
| | - Isabela de P Lima
- Programa, de Pós-Graduação em Química, Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, Niterói, Rio de Janeiro, Brazil
| | - Amanda P Faillace
- Programa, de Pós-Graduação em Química, Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, Niterói, Rio de Janeiro, Brazil
| | - Vinicius G C Madriaga
- Programa, de Pós-Graduação em Química, Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, Niterói, Rio de Janeiro, Brazil
| | - Thiago de M Lima
- Programa, de Pós-Graduação em Química, Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, Niterói, Rio de Janeiro, Brazil
| | - Fernando A S Vaz
- Programa, de Pós-Graduação em Química, Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, Niterói, Rio de Janeiro, Brazil
| | - Flávia F de C Marques
- Programa, de Pós-Graduação em Química, Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, Niterói, Rio de Janeiro, Brazil
| | - Lucas M Duarte
- Programa, de Pós-Graduação em Química, Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, Niterói, Rio de Janeiro, Brazil
| |
Collapse
|
7
|
Yang S, Li Y, Chen L, Wang H, Shang L, He P, Dong H, Wang G, Ding G. Fabrication of Carbon-Based Quantum Dots via a "Bottom-Up" Approach: Topology, Chirality, and Free Radical Processes in "Building Blocks". SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023:e2205957. [PMID: 36610043 DOI: 10.1002/smll.202205957] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Revised: 12/28/2022] [Indexed: 06/17/2023]
Abstract
The discovery of carbon-based quantum dots (CQDs) has allowed opportunities for fluorescence bioimaging, tumor diagnosis and treatment, and photo-/electro-catalysis. Nevertheless, in the existing reviews related to the "bottom-up" approaches, attention is mainly paid to the applications of CQDs but not the formation mechanism of CQDs, which mainly derived from the high complexities during the synthesis of CQDs. Among the various synthetic methods, using small molecules as "building blocks", the development of a "bottom-up" approach has promoted the structural design, modulation of the photoluminescence properties, and control of the interfacial properties of CQDs. On the other hand, many works have demonstrated the "building blocks"-dependent properties of CQDs. In this review, from one of the most important variables, the relationships among intrinsic properties of "building blocks" and photoluminescence properties of CQDs are summarized. The topology, chirality, and free radical process are selected as descriptors for the intrinsic properties of "building blocks". This review focuses on the induction and summary of recent research results from the "bottom-up" process. Moreover, several empirical rules pertaining thereto are also proposed.
Collapse
Affiliation(s)
- Siwei Yang
- Joint Laboratory of Graphene Materials and Applications, State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, P. R. China
- College of Materials Science and Opto-Electronic Technology, University of Chinese Academy of Sciences, Beijing, 100049, P. R. China
| | - Yongqiang Li
- Joint Laboratory of Graphene Materials and Applications, State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, P. R. China
- College of Materials Science and Opto-Electronic Technology, University of Chinese Academy of Sciences, Beijing, 100049, P. R. China
| | - Liangfeng Chen
- Joint Laboratory of Graphene Materials and Applications, State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, P. R. China
- College of Materials Science and Opto-Electronic Technology, University of Chinese Academy of Sciences, Beijing, 100049, P. R. China
| | - Hang Wang
- Joint Laboratory of Graphene Materials and Applications, State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, P. R. China
- College of Materials Science and Opto-Electronic Technology, University of Chinese Academy of Sciences, Beijing, 100049, P. R. China
| | - Liuyang Shang
- Joint Laboratory of Graphene Materials and Applications, State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, P. R. China
- College of Materials Science and Opto-Electronic Technology, University of Chinese Academy of Sciences, Beijing, 100049, P. R. China
| | - Peng He
- Joint Laboratory of Graphene Materials and Applications, State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, P. R. China
- College of Materials Science and Opto-Electronic Technology, University of Chinese Academy of Sciences, Beijing, 100049, P. R. China
| | - Hui Dong
- Joint Laboratory of Graphene Materials and Applications, State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, P. R. China
- College of Materials Science and Opto-Electronic Technology, University of Chinese Academy of Sciences, Beijing, 100049, P. R. China
| | - Gang Wang
- Department of Microelectronic Science and Engineering, School of Physical Science and Technology, Ningbo University, Ningbo, 315211, P. R. China
| | - Guqiao Ding
- Joint Laboratory of Graphene Materials and Applications, State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, P. R. China
- College of Materials Science and Opto-Electronic Technology, University of Chinese Academy of Sciences, Beijing, 100049, P. R. China
| |
Collapse
|
8
|
Singh SK, Gogoi P, Deb A, Gooh Pattader PS. Chiral resolution of racemic amines in µ-reactor-crystallizer. Chem Eng Sci 2022. [DOI: 10.1016/j.ces.2022.117686] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
9
|
Přibyl M, Izák P, Slouka Z. A mathematical model of a lateral electrochromatography device for continuous chiral separation. Sep Purif Technol 2022. [DOI: 10.1016/j.seppur.2021.120033] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
10
|
Qu K, Xu J, Xue Y, Guo J, Gao Z, Song YY, Mei Y. Near Infrared Light-Driven Photothermal Effect on Homochiral Au/TiO 2 Nanotube Arrays for Enantioselective Desorption. Anal Chem 2021; 94:588-592. [PMID: 34931801 DOI: 10.1021/acs.analchem.1c04981] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Chiral enantiomers have different effects on biological processes. Enantiomer separation is significant and necessary. Herein, a photothermal (PT) effect-derived enantioselective desorption strategy based on homochiral Au/TiO2 nanotubes (NTs) is developed. Using 3,4-dihydroxyphenylalanine (DOPA) as the model enantiomer, an obvious selective desorption of L/D-DOPA can be achieved by the NIR light-triggered local temperature enhancement. Molecular docking simulation further verifies that the distinct affinity precipitated by the different hydrogen bonds between homochiral sorbent and target enantiomers is the origin of enantioselective desorption. This desorption strategy provides a green and alternative approach for the selective separation of chiral molecules.
Collapse
Affiliation(s)
- Kuanzhi Qu
- College of Sciences, Northeastern University, Shenyang 110819, China
| | - Jing Xu
- College of Sciences, Northeastern University, Shenyang 110819, China
| | - Yuanfei Xue
- State Key Laboratory of Precision Spectroscopy, School of Physics and Electronic Science, East China Normal University, Shanghai 200062, China.,NYU-ECNU Center for Computational Chemistry at NYU Shanghai, Shanghai 200062, China.,Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, Shanxi 030006, China
| | - Junli Guo
- College of Sciences, Northeastern University, Shenyang 110819, China
| | - Zhida Gao
- College of Sciences, Northeastern University, Shenyang 110819, China
| | - Yan-Yan Song
- College of Sciences, Northeastern University, Shenyang 110819, China
| | - Ye Mei
- State Key Laboratory of Precision Spectroscopy, School of Physics and Electronic Science, East China Normal University, Shanghai 200062, China.,NYU-ECNU Center for Computational Chemistry at NYU Shanghai, Shanghai 200062, China.,Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, Shanxi 030006, China
| |
Collapse
|
11
|
Chankvetadze B. Application of enantioselective separation techniques to bioanalysis of chiral drugs and their metabolites. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116332] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
12
|
Zhang Y, Hu X, Wang Q, He P. Investigation of hydroxypropyl-β-cyclodextrin-based synergistic system with chiral nematic mesoporous silica as chiral stationary phase for enantiomeric separation in microchip electrophoresis. Talanta 2020; 218:121121. [DOI: 10.1016/j.talanta.2020.121121] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2019] [Revised: 04/29/2020] [Accepted: 05/03/2020] [Indexed: 10/24/2022]
|
13
|
Abstract
AbstractThere is a growing need for chemical analyses to be performed in the field, at the point of need. Tools and techniques often found in analytical chemistry laboratories are necessary in performing these analyses, yet have, historically, been unable to do so owing to their size, cost and complexity. Technical advances in miniaturisation and liquid chromatography are enabling the translation of these techniques out of the laboratory, and into the field. Here we examine the advances that are enabling portable liquid chromatography (LC). We explore the evolution of portable instrumentation from its inception to the most recent advances, highlighting the trends in the field and discussing the necessary criteria for developing in-field solutions. While instrumentation is becoming more capable it has yet to find adoption outside of research.
Collapse
|
14
|
Li K, Hu W, Zhou Y, Dou X, Wang X, Zhang B, Guo G. Single-particle-frit-based packed columns for microchip chromatographic analysis of neurotransmitters. Talanta 2020; 215:120896. [PMID: 32312441 DOI: 10.1016/j.talanta.2020.120896] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2020] [Revised: 02/28/2020] [Accepted: 03/03/2020] [Indexed: 11/18/2022]
Abstract
The fabrication of effective microchip liquid chromatography (LC) systems tends to be limited by the availability of suitable chromatographic columns. Herein, we developed a glass microchip LC system in which porous single-particle silica was adopted as frits and a freeze-thaw valve was utilized to achieve sample injection without interfering with sampling. The fabrication of single-particle-frit-based packed columns did not require an additional packing channel, thus avoiding dead volumes within the channel interface that can influence chromatographic separation. Further, the length of the packed column could be adjusted using the location of single-particle frits within the column channel. The fabricated frits exhibited high mechanical strength, good permeability, and tolerance for high pressures during chromatographic separation. In particular, the developed microchip LC system was able to withstand high separation pressures of more than 5000 psi. The microchip LC system was applied to the separation of neurotransmitters. Three different monoamine neurotransmitters were completely separated within 5 min with theoretical plate numbers on the order of 100,000 plates m-1. The microchip LC system has a potential for application in a variety of fields including environmental analysis, food safety, drug analysis, and biomedicine.
Collapse
Affiliation(s)
- Ke Li
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Chemistry Engineering, Beijing University of Technology, Beijing, 100124, PR China
| | - Wangyan Hu
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Chemistry Engineering, Beijing University of Technology, Beijing, 100124, PR China
| | - Yingyan Zhou
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Chemistry Engineering, Beijing University of Technology, Beijing, 100124, PR China
| | - Xiangnan Dou
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Chemistry Engineering, Beijing University of Technology, Beijing, 100124, PR China
| | - Xiayan Wang
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Chemistry Engineering, Beijing University of Technology, Beijing, 100124, PR China.
| | - Bo Zhang
- College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, 361005, PR China
| | - Guangsheng Guo
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Chemistry Engineering, Beijing University of Technology, Beijing, 100124, PR China.
| |
Collapse
|
15
|
Potential and current limitations of superficially porous silica as a carrier for polysaccharide-based chiral selectors in separation of enantiomers in high-performance liquid chromatography. J Chromatogr A 2020; 1625:461297. [DOI: 10.1016/j.chroma.2020.461297] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2020] [Revised: 05/17/2020] [Accepted: 05/30/2020] [Indexed: 01/03/2023]
|
16
|
Abstract
Background::
Nano level chiral separation is necessary and demanding in the development
of the drug, genomic, proteomic, and other chemical and the environmental sciences. Few drugs exist
in human body cells for some days at nano level concentrations, that are out of the jurisdiction of the
detection by standard separation techniques. Likewise, the separation and identification of xenobiotics
and other environmental contaminants (at nano or low levels) are necessary for our healthiness.
Discussion:
Conclusion:
This article will be beneficial for chiral chromatographers, academicians, pharmaceutical
industries, environmental researchers and Government regulation authorities.
Collapse
Affiliation(s)
- Al Arsh Basheer
- State University of New York, Flint Entrance, Amherst, NY 14260, Buffalo, United States
| | - Iqbal Hussain
- Department of General Studies, Jubail Industrial College, Jubail Industrial City, Jubail, Saudi Arabia
| | - Marcus T. Scotti
- Cheminformatics Laboratory - Postgraduate Program in Natural Products and Synthetic Bioactive, Federal University of Paraiba-Campus I, 58051-970, Joao Pessoa, PB, Brazil
| | - Luciana Scotti
- Teaching and Research Management - University Hospital, Cheminformatics Laboratory - Postgraduate Program in Natural Products and Synthetic Bioactive, Federal University of Paraiba-Campus I, 58051-970, Joao Pessoa, PB, Brazil
| | - Imran Ali
- Department of Chemistry, College of Sciences, Taibah University, Al-Medina Al-Munawara - 41477, Saudi Arabia
| |
Collapse
|
17
|
Miniaturized liquid chromatography focusing on analytical columns and mass spectrometry: A review. Anal Chim Acta 2020; 1103:11-31. [DOI: 10.1016/j.aca.2019.12.064] [Citation(s) in RCA: 47] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2019] [Revised: 12/19/2019] [Accepted: 12/20/2019] [Indexed: 12/17/2022]
|
18
|
Piendl SK, Geissler D, Weigelt L, Belder D. Multiple Heart-Cutting Two-Dimensional Chip-HPLC Combined with Deep-UV Fluorescence and Mass Spectrometric Detection. Anal Chem 2020; 92:3795-3803. [DOI: 10.1021/acs.analchem.9b05206] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- Sebastian K. Piendl
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| | - David Geissler
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| | - Laura Weigelt
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| | - Detlev Belder
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| |
Collapse
|
19
|
On-chip integration of normal phase high-performance liquid chromatography and droplet microfluidics introducing ethylene glycol as polar continuous phase for the compartmentalization of n-heptane eluents. J Chromatogr A 2020; 1612:460653. [DOI: 10.1016/j.chroma.2019.460653] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2019] [Revised: 10/08/2019] [Accepted: 10/23/2019] [Indexed: 01/06/2023]
|
20
|
Chankvetadze B. Recent trends in preparation, investigation and application of polysaccharide-based chiral stationary phases for separation of enantiomers in high-performance liquid chromatography. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2019.115709] [Citation(s) in RCA: 96] [Impact Index Per Article: 24.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
21
|
Shedania Z, Kakava R, Volonterio A, Farkas T, Chankvetadze B. Separation of enantiomers of chiral sulfoxides in high-performance liquid chromatography with cellulose-based chiral selectors using acetonitrile and acetonitrile-water mixtures as mobile phases. J Chromatogr A 2020; 1609:460445. [DOI: 10.1016/j.chroma.2019.460445] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2019] [Revised: 08/03/2019] [Accepted: 08/08/2019] [Indexed: 10/26/2022]
|
22
|
|
23
|
Kaplitz AS, Kresge GA, Selover B, Horvat L, Franklin EG, Godinho JM, Grinias KM, Foster SW, Davis JJ, Grinias JP. High-Throughput and Ultrafast Liquid Chromatography. Anal Chem 2019; 92:67-84. [DOI: 10.1021/acs.analchem.9b04713] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Alexander S. Kaplitz
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| | - Glenn A. Kresge
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| | - Benjamin Selover
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| | - Leah Horvat
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| | | | - Justin M. Godinho
- Advanced Materials Technology, Inc., Wilmington, Delaware 19810, United States
| | - Kaitlin M. Grinias
- Analytical Platforms & Platform Modernization, GlaxoSmithKline, Upper Providence, Collegeville, Pennsylvania 19426, United States
| | - Samuel W. Foster
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| | - Joshua J. Davis
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| | - James P. Grinias
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| |
Collapse
|
24
|
Comparative study on enantiomer resolving ability of amylose tris(3-chloro-5-methylphenylcarbamate) covalently immobilized onto silica in nano-liquid chromatography and capillary electrochromatography. J Chromatogr A 2019; 1606:460425. [PMID: 31471135 DOI: 10.1016/j.chroma.2019.460425] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2019] [Revised: 08/02/2019] [Accepted: 08/03/2019] [Indexed: 12/14/2022]
Abstract
In the present study separation of enantiomers of some chiral neutral and weakly acidic analytes was investigated on the chiral stationary phase (CSP) made by covalent immobilization of amylose tris(3-chloro-5-methylphenylcarbamate) onto silica in nano-liquid chromatography (nano-LC) and capillary electrochromatography (CEC) in acetonitrile and aqueous acetonitrile. Few comparisons were made also between the enantioseparations in nano-LC and high-performance liquid chromatography (HPLC) with the chiral column of 4.6 × 250 mm dimension. Slightly better separation of enantiomers was observed in HPLC mode compared to nano-LC mode. It was shown that in the capillary columns packed with the CSP containing about 20% (w/w) of a covalently immobilized neutral chiral selector, amylose tris(3-chloro-5-methylphenylcarbamate), sufficient electroosmotic flow has been generated and enantioseparations with reasonable analysis time were performed also in CEC mode. It was shown once again that CEC offers a clear advantage over nano-LC from the viewpoint of plate numbers and peak resolution.
Collapse
|
25
|
Ai Y, Zhang F, Wang C, Xie R, Liang Q. Recent progress in lab-on-a-chip for pharmaceutical analysis and pharmacological/toxicological test. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.06.026] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
26
|
Xiang P, Yang Y, Zhao Z, Chen M, Liu S. Ultrafast Gradient Separation with Narrow Open Tubular Liquid Chromatography. Anal Chem 2019; 91:10738-10743. [PMID: 31288520 DOI: 10.1021/acs.analchem.9b02190] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Separation speed and resolution are two important figures of merit in chromatography. Often, one gains the speed at the cost of the resolution, and vice versa. Scientists have employed short-packed columns for ultrafast separations but encountered challenges such as limited mobile phase velocity, extra-column effect caused band broadening, and column packing difficulty. We have recently demonstrated ultrahigh resolutions of narrow open tubular liquid chromatography (NOTLC); this allows us to trade some of the resolution for speed. In this work, we explored NOTLC for ultrafast LC separations. We used a 2.7 cm (effective length) narrow open tubular (NOT) column and showed a baseline separation of 6 amino acids in less than 700 ms. Ways to further increase the speed were discussed. Using short narrow open tubular (NOT) columns to perform ultrafast separation we overcame the challenges from using short packed columns. To demonstrate the feasibility of using this ultrafast separation technique for practical applications, we separated complex protein digests; peptides were nicely resolved in ∼1 min.
Collapse
Affiliation(s)
- Piliang Xiang
- Department of Chemistry and Biochemistry , University of Oklahoma , 101 Stephenson Parkway , Norman , Oklahoma 73019 , United States
| | - Yu Yang
- Department of Chemistry and Biochemistry , University of Oklahoma , 101 Stephenson Parkway , Norman , Oklahoma 73019 , United States
| | - Zhitao Zhao
- Department of Chemistry and Biochemistry , University of Oklahoma , 101 Stephenson Parkway , Norman , Oklahoma 73019 , United States
| | - Mingli Chen
- Department of Chemistry , Northeastern University , Shenyang 110819 , P. R. China
| | - Shaorong Liu
- Department of Chemistry and Biochemistry , University of Oklahoma , 101 Stephenson Parkway , Norman , Oklahoma 73019 , United States
| |
Collapse
|
27
|
Chromatographic and thermodynamic comparison of amylose tris(3-chloro-5-methylphenylcarbamate) coated or covalently immobilized on silica in high-performance liquid chromatographic separation of the enantiomers of select chiral weak acids. J Chromatogr A 2019; 1602:228-236. [PMID: 31126590 DOI: 10.1016/j.chroma.2019.05.026] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2019] [Revised: 05/10/2019] [Accepted: 05/13/2019] [Indexed: 11/21/2022]
Abstract
The separation of enantiomers of some chiral weak acids was studied in HPLC with chiral HPLC columns prepared by coating or covalent immobilization of the same chiral selector, namely amylose tris(3-chloro-5-methylphenylcarbamate) onto silica. After screening some representatives of arylpropionic acid derivatives, coumarins and barbiturates in hydrocarbon-alcohol type mobile phases, we studied the temperature dependence of separation parameters for ketoprofen and naproxen. Instances of reversal of the enantiomer elution order were observed function of column temperature, nature of polar modifier and its content in the mobile phase, as well as between the coated and covalently immobilized versions of the columns made with more-or-less the same chiral selector. Thermodynamic parameters such as Gibb's free energy, the standard molar entropy and the standard molar enthalpy of analyte transfer from the mobile to the stationary phase were calculated in some cases in order to explain the differences observed in the enantiomer separation ability and pattern of coated and covalently immobilized columns.
Collapse
|
28
|
Piendl SK, Raddatz CR, Hartner NT, Thoben C, Warias R, Zimmermann S, Belder D. 2D in Seconds: Coupling of Chip-HPLC with Ion Mobility Spectrometry. Anal Chem 2019; 91:7613-7620. [DOI: 10.1021/acs.analchem.9b00302] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Sebastian K. Piendl
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| | - Christian-Robert Raddatz
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstrasse 9A, 30167 Hannover, Germany
| | - Nora T. Hartner
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| | - Christian Thoben
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstrasse 9A, 30167 Hannover, Germany
| | - Rico Warias
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| | - Stefan Zimmermann
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstrasse 9A, 30167 Hannover, Germany
| | - Detlev Belder
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| |
Collapse
|
29
|
Heiland JJ, Geissler D, Piendl SK, Warias R, Belder D. Supercritical-Fluid Chromatography On-Chip with Two-Photon-Excited-Fluorescence Detection for High-Speed Chiral Separations. Anal Chem 2019; 91:6134-6140. [DOI: 10.1021/acs.analchem.9b00726] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Josef J. Heiland
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| | - David Geissler
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| | - Sebastian K. Piendl
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| | - Rico Warias
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| | - Detlev Belder
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| |
Collapse
|
30
|
The Way to Ultrafast, High-Throughput Enantioseparations of Bioactive Compounds in Liquid and Supercritical Fluid Chromatography. Molecules 2018; 23:molecules23102709. [PMID: 30347852 PMCID: PMC6222346 DOI: 10.3390/molecules23102709] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2018] [Revised: 10/16/2018] [Accepted: 10/17/2018] [Indexed: 01/15/2023] Open
Abstract
Until less than 10 years ago, chiral separations were carried out with columns packed with 5 or 3 μm fully porous particles (FPPs). Times to resolve enantiomeric mixtures were easily larger than 30 min, or so. Pushed especially by stringent requirements from medicinal and pharmaceutical industries, during the last years the field of chiral separations by liquid chromatography has undergone what can be defined a “true revolution”. With the purpose of developing ever faster and efficient method of separations, indeed, very efficient particle formats, such as superficially porous particles (SPPs) or sub-2 μm FPPs, have been functionalized with chiral selectors and employed in ultrafast applications. Thanks to the use of short column (1–2 cm long), packed with these extremely efficient chiral stationary phases (CSPs), operated at very high flow rates (5–8 mL/min), resolution of racemates could be accomplished in very short time, in many cases less than 1 s in normal-, reversed-phase and HILIC conditions. These CSPs have been found to be particularly promising also to carry out high-throughput separations under supercritical fluid chromatography (SFC) conditions. The most important results that have been recently achieved in terms of ultrafast, high-throughput enantioseparations both in liquid and supercritical fluid chromatography with particular attention to the very important field of bioactive chiral compounds will be reviewed in this manuscript. Attention will be focused not only on the latest introduced CSPs and their applications, but also on instrumental modifications which are required in some cases in order to fully exploit the intrinsic potential of new generation chiral columns.
Collapse
|
31
|
Khundadze N, Pantsulaia S, Fanali C, Farkas T, Chankvetadze B. On our way to sub-second separations of enantiomers in high-performance liquid chromatography. J Chromatogr A 2018; 1572:37-43. [PMID: 30139619 DOI: 10.1016/j.chroma.2018.08.027] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2018] [Revised: 08/02/2018] [Accepted: 08/11/2018] [Indexed: 11/17/2022]
Abstract
In this study our preliminary attempt for obtaining fast and highly efficient separations of enantiomers in high-performance liquid chromatography with slightly modified state-of-the-art commercial instrumentation is described. In order to reach this goal after careful selection of chiral analytes, the preparation of chiral stationary phase (CSP), mobile phase composition and column dimensions were optimized. The concept of segmented chiral-achiral column was introduced. As the result of these optimizations baseline separation of enantiomers was achieved with the analysis time between 1-2 s.
Collapse
Affiliation(s)
- Nana Khundadze
- Institute of Physical and Analytical Chemistry, School of Exact and Natural Sciences, Tbilisi State University, Chavchavadze Ave. 3, 0179 Tbilisi, Georgia
| | - Salome Pantsulaia
- Institute of Physical and Analytical Chemistry, School of Exact and Natural Sciences, Tbilisi State University, Chavchavadze Ave. 3, 0179 Tbilisi, Georgia
| | - Chiara Fanali
- Department of Medicine, University Campus Bio-Medico of Rome, Via Alvaro del Portillo 21, 00128 Rome, Italy
| | - Tivadar Farkas
- Phenomenex Inc., 411 Madrid Ave., Torrance, 90501 CA, USA
| | - Bezhan Chankvetadze
- Institute of Physical and Analytical Chemistry, School of Exact and Natural Sciences, Tbilisi State University, Chavchavadze Ave. 3, 0179 Tbilisi, Georgia.
| |
Collapse
|
32
|
Aydoğan C. Chiral separation and determination of amino acid enantiomers in fruit juice by open-tubular nano liquid chromatography. Chirality 2018; 30:1144-1149. [DOI: 10.1002/chir.23006] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2018] [Revised: 06/10/2018] [Accepted: 07/09/2018] [Indexed: 01/18/2023]
Affiliation(s)
- Cemil Aydoğan
- Department of Food Engineering; Bingöl University; Bingöl Turkey
| |
Collapse
|
33
|
Bezhitashvili L, Bardavelidze A, Mskhiladze A, Gumustas M, Ozkan SA, Volonterio A, Farkas T, Chankvetadze B. Application of cellulose 3,5-dichlorophenylcarbamate covalently immobilized on superficially porous silica for the separation of enantiomers in high-performance liquid chromatography. J Chromatogr A 2018; 1571:132-139. [PMID: 30098733 DOI: 10.1016/j.chroma.2018.08.011] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2018] [Revised: 07/27/2018] [Accepted: 08/03/2018] [Indexed: 02/01/2023]
Abstract
Our earlier studies have demonstrated the applicability of polysaccharide-based chiral selectors in combination with superficially porous (or core-shell) silica (SPS) particles for the preparation of highly efficient chiral stationary phases (CSP). In earlier studies, CSPs were prepared by coating (adsorption) of the chiral selector onto the surface of silica. In this study we report for the first time the CSP obtained by covalent immobilization of a chiral selector onto the surface of SPS particles. The applicability of this CSP for the separation of enantiomers in pure methanol and acetonitrile, as well as in n-hexane/2-propanol mobile phases is shown. The effect of the injected sample amount, mobile phase flow rate and detection frequency on separation performance were studied, as well as high efficiency separation of enantiomers with the analysis time less than 30 s was attempted.
Collapse
Affiliation(s)
- Lia Bezhitashvili
- Institute of Physical and Analytical Chemistry, School of Exact and Natural Sciences, Tbilisi State University, Chavchavadze Ave 3, 0179 Tbilisi, Georgia
| | - Anna Bardavelidze
- Institute of Physical and Analytical Chemistry, School of Exact and Natural Sciences, Tbilisi State University, Chavchavadze Ave 3, 0179 Tbilisi, Georgia
| | - Antonina Mskhiladze
- Institute of Physical and Analytical Chemistry, School of Exact and Natural Sciences, Tbilisi State University, Chavchavadze Ave 3, 0179 Tbilisi, Georgia; Faculty of Natural Sciences and Healthcare, Sokhumi State University, Polytkovskaya 9, 0186 Tbilisi, Georgia
| | - Mehmet Gumustas
- Ankara University, Institute of Forensic Sciences, Department of Forensic Toxicology, Ankara, Turkey; Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, Anadolu Ave, 06100 Ankara, Turkey
| | - Sibel A Ozkan
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, Anadolu Ave, 06100 Ankara, Turkey
| | - Alessandro Volonterio
- Department of Chemistry, Materials and Chemical Engineering "G. Natta" Politecnico di Milano, Via Mancinelli 7-20131, Milano, Italy; C.N.R. Istituto di Chimica del Riconoscimento Molecolare (ICRM), Via Mancinelli 7, 20131 Milano, Italy
| | - Tivadar Farkas
- Phenomenex Inc., 411 Madrid Ave., Torrance, 90501 CA, USA
| | - Bezhan Chankvetadze
- Institute of Physical and Analytical Chemistry, School of Exact and Natural Sciences, Tbilisi State University, Chavchavadze Ave 3, 0179 Tbilisi, Georgia.
| |
Collapse
|
34
|
Kecskemeti A, Gaspar A. Particle-based liquid chromatographic separations in microfluidic devices - A review. Anal Chim Acta 2018; 1021:1-19. [DOI: 10.1016/j.aca.2018.01.064] [Citation(s) in RCA: 46] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2017] [Revised: 01/18/2018] [Accepted: 01/21/2018] [Indexed: 01/06/2023]
|
35
|
Haghighi F, Talebpour Z, Nezhad AS. Towards fully integrated liquid chromatography on a chip: Evolution and evaluation. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2018.05.002] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
36
|
Khatiashvili T, Kakava R, Matarashvili I, Tabani H, Fanali C, Volonterio A, Farkas T, Chankvetadze B. Separation of enantiomers of selected chiral sulfoxides with cellulose tris(4-chloro-3-methylphenylcarbamate)-based chiral columns in high-performance liquid chromatography with very high separation factor. J Chromatogr A 2018; 1545:59-66. [DOI: 10.1016/j.chroma.2018.02.054] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2018] [Revised: 02/17/2018] [Accepted: 02/25/2018] [Indexed: 11/16/2022]
|
37
|
Beridze N, Tsutskiridze E, Takaishvili N, Farkas T, Chankvetadze B. Comparative Enantiomer-Resolving Ability of Coated and Covalently Immobilized Versions of Two Polysaccharide-Based Chiral Selectors in High-Performance Liquid Chromatography. Chromatographia 2018. [DOI: 10.1007/s10337-018-3493-5] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
38
|
Bunzel HA, Garrabou X, Pott M, Hilvert D. Speeding up enzyme discovery and engineering with ultrahigh-throughput methods. Curr Opin Struct Biol 2018; 48:149-156. [PMID: 29413955 DOI: 10.1016/j.sbi.2017.12.010] [Citation(s) in RCA: 84] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2017] [Accepted: 12/26/2017] [Indexed: 01/24/2023]
Abstract
Exploring the sequence space of enzyme catalysts is ultimately a numbers game. Ultrahigh-throughput screening methods for rapid analysis of millions of variants are therefore increasingly important for investigating sequence-function relationships, searching large metagenomic libraries for interesting activities, and accelerating enzyme evolution in the laboratory. Recent applications of such technologies are reviewed here, with a particular focus on the practical benefits of droplet-based microfluidics for the directed evolution of natural and artificial enzymes. Broader implementation of such rapid, cost-effective screening technologies is likely to redefine the way enzymes are studied and engineered for academic and industrial purposes.
Collapse
Affiliation(s)
- Hans Adrian Bunzel
- Laboratory of Organic Chemistry, ETH Zurich, Zurich CH-8093, Switzerland
| | - Xavier Garrabou
- Laboratory of Organic Chemistry, ETH Zurich, Zurich CH-8093, Switzerland
| | - Moritz Pott
- Laboratory of Organic Chemistry, ETH Zurich, Zurich CH-8093, Switzerland
| | - Donald Hilvert
- Laboratory of Organic Chemistry, ETH Zurich, Zurich CH-8093, Switzerland.
| |
Collapse
|
39
|
Ciogli A, Ismail OH, Mazzoccanti G, Villani C, Gasparrini F. Enantioselective ultra high performance liquid and supercritical fluid chromatography: The race to the shortest chromatogram. J Sep Sci 2018; 41:1307-1318. [PMID: 29319915 DOI: 10.1002/jssc.201701406] [Citation(s) in RCA: 49] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2017] [Revised: 12/23/2017] [Accepted: 12/25/2017] [Indexed: 11/11/2022]
Abstract
The ever-increasing need for enantiomerically pure chiral compounds has greatly expanded the number of enantioselective separation methods available for the precise and accurate measurements of the enantiomeric purity. The introduction of chiral stationary phases for liquid chromatography in the last decades has revolutionized the routine methods to determine enantiomeric purity of chiral drugs, agrochemicals, fragrances, and in general of organic and organometallic compounds. In recent years, additional efforts have been placed on faster, enantioselective analytical methods capable to fulfill the high throughput requirements of modern screening procedures. Efforts in this field, capitalizing on improved chromatographic particle technology and dedicated instrumentation, have led to highly efficient separations that are routinely completed on the seconds time scale. An overview of the recent achievements in the field of ultra-high-resolution chromatography on column packed with chiral stationary phases, both based on sub-2 μm fully porous and sub-3 μm superficially porous particles, will be given, with an emphasis on very recent studies on ultrafast chiral separations.
Collapse
Affiliation(s)
- Alessia Ciogli
- Dipartimento di Chimica e Tecnologie del Farmaco, "Sapienza" Università di Roma, Rome, Italy
| | - Omar H Ismail
- Dipartimento di Chimica e Tecnologie del Farmaco, "Sapienza" Università di Roma, Rome, Italy
| | - Giulia Mazzoccanti
- Dipartimento di Chimica e Tecnologie del Farmaco, "Sapienza" Università di Roma, Rome, Italy
| | - Claudio Villani
- Dipartimento di Chimica e Tecnologie del Farmaco, "Sapienza" Università di Roma, Rome, Italy
| | - Francesco Gasparrini
- Dipartimento di Chimica e Tecnologie del Farmaco, "Sapienza" Università di Roma, Rome, Italy
| |
Collapse
|
40
|
Catani M, Felletti S, Ismail OH, Gasparrini F, Pasti L, Marchetti N, De Luca C, Costa V, Cavazzini A. New frontiers and cutting edge applications in ultra high performance liquid chromatography through latest generation superficially porous particles with particular emphasis to the field of chiral separations. Anal Bioanal Chem 2018; 410:2457-2465. [DOI: 10.1007/s00216-017-0842-4] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Revised: 12/05/2017] [Accepted: 12/15/2017] [Indexed: 11/28/2022]
|
41
|
Gerhardt RF, Peretzki AJ, Piendl SK, Belder D. Seamless Combination of High-Pressure Chip-HPLC and Droplet Microfluidics on an Integrated Microfluidic Glass Chip. Anal Chem 2017; 89:13030-13037. [DOI: 10.1021/acs.analchem.7b04331] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Affiliation(s)
- Renata F. Gerhardt
- Institute of Analytical Chemistry, University of Leipzig, Linnéstraße 3, 04103 Leipzig, Germany
| | - Andrea J. Peretzki
- Institute of Analytical Chemistry, University of Leipzig, Linnéstraße 3, 04103 Leipzig, Germany
| | - Sebastian K. Piendl
- Institute of Analytical Chemistry, University of Leipzig, Linnéstraße 3, 04103 Leipzig, Germany
| | - Detlev Belder
- Institute of Analytical Chemistry, University of Leipzig, Linnéstraße 3, 04103 Leipzig, Germany
| |
Collapse
|
42
|
|
43
|
Professor Bezhan Chankvetadze turns 60. Electrophoresis 2017; 38:1818-1821. [DOI: 10.1002/elps.201700240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
44
|
Xu S, Mo R, Jin C, Cui X, Bai R, Ji Y. Mesoporous silica nanoparticles incorporated hybrid monolithic stationary phase immobilized with pepsin for enantioseparation by capillary electrochromatography. J Pharm Biomed Anal 2017; 140:190-198. [DOI: 10.1016/j.jpba.2017.03.013] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2017] [Accepted: 03/09/2017] [Indexed: 11/26/2022]
|
45
|
D'Orazio G, Kakava R, Volonterio A, Fanali S, Chankvetadze B. An attempt for fast separation of enantiomers in nano-liquid chromatography and capillary electrochromatography. Electrophoresis 2017; 38:1932-1938. [DOI: 10.1002/elps.201700126] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2017] [Revised: 04/04/2017] [Accepted: 04/05/2017] [Indexed: 11/08/2022]
Affiliation(s)
- Giovanni D'Orazio
- Institute of Chemical Methodologies; Italian National Research Council (CNR); Monterotondo Italy
| | - Rusudan Kakava
- Institute of Physical and Analytical Chemistry, School of Exact and Natural Sciences; Tbilisi State University; Tbilisi Georgia
| | - Alessandro Volonterio
- Department of Chemistry; Materials and Chemical Engineering “G. Natta” Politecnico di Milano; Milano Italy
- C.N.R. Istituto di Chimica del Riconoscimento Molecolare (ICRM); Milano Italy
| | - Salvatore Fanali
- Institute of Chemical Methodologies; Italian National Research Council (CNR); Monterotondo Italy
| | - Bezhan Chankvetadze
- Institute of Physical and Analytical Chemistry, School of Exact and Natural Sciences; Tbilisi State University; Tbilisi Georgia
| |
Collapse
|
46
|
Wu D, Yin Q, Cai P, Zhao X, Pan Y. Enhancement of visual chiral sensing via an anion-binding approach: Novel ionic liquids as the chiral selectors. Anal Chim Acta 2017; 962:97-103. [DOI: 10.1016/j.aca.2017.01.015] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2016] [Revised: 01/08/2017] [Accepted: 01/11/2017] [Indexed: 12/11/2022]
|
47
|
Fanali S. An overview to nano-scale analytical techniques: Nano-liquid chromatography and capillary electrochromatography. Electrophoresis 2017; 38:1822-1829. [PMID: 28256745 DOI: 10.1002/elps.201600573] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2016] [Revised: 02/17/2017] [Accepted: 02/21/2017] [Indexed: 01/04/2023]
Abstract
Nano-liquid chromatography (nano-LC) and CEC are microfluidic techniques mainly used for analytical purposes. They have been applied to the separation and analysis of a large number of compounds, e.g., peptides, proteins, drugs, enantiomers, antibiotics, pesticides, nutraceutical, etc. Analytes separation is carried out into capillaries containing selected stationary phase. The mobile phase is moved either by a pump (nano-LC) or by an EOF, respectively. The two tools can offer some advantages over conventional techniques, e.g., high selectivity, separation efficiency, resolution, short analysis time and consumption of low volumes of mobile phase. Flow rates in the range 50-800 nL/min are usually applied. The low flow rate reduces the chromatographic dilution increasing the mass sensitivity. Special attention must be paid in avoiding peak dispersion selecting the appropriate detector, injector and tube connection. Finally due to the low flow rate these microfluidic techniques can be easily coupled with mass spectrometry.
Collapse
Affiliation(s)
- Salvatore Fanali
- Institute of Chemical Methodologies, Italian National Research Council, Monterotondo, Italy
| |
Collapse
|
48
|
Heiland JJ, Lotter C, Stein V, Mauritz L, Belder D. Temperature Gradient Elution and Superheated Eluents in Chip-HPLC. Anal Chem 2017; 89:3266-3271. [DOI: 10.1021/acs.analchem.7b00142] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Affiliation(s)
- Josef J. Heiland
- Institute
of Analytical Chemistry, Department of Chemistry and Mineralogy, University of Leipzig, Linnéstraße 3, 04103 Leipzig, Germany
| | - Carsten Lotter
- Institute
of Analytical Chemistry, Department of Chemistry and Mineralogy, University of Leipzig, Linnéstraße 3, 04103 Leipzig, Germany
| | - Volkmar Stein
- Fraunhofer ICT-IMM, Carl-Zeiss-Straße
18-20, 55129 Mainz, Germany
| | - Laura Mauritz
- Institute
of Analytical Chemistry, Department of Chemistry and Mineralogy, University of Leipzig, Linnéstraße 3, 04103 Leipzig, Germany
| | - Detlev Belder
- Institute
of Analytical Chemistry, Department of Chemistry and Mineralogy, University of Leipzig, Linnéstraße 3, 04103 Leipzig, Germany
| |
Collapse
|
49
|
Fanali S. Nano-liquid chromatography applied to enantiomers separation. J Chromatogr A 2017; 1486:20-34. [DOI: 10.1016/j.chroma.2016.10.028] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2016] [Revised: 10/01/2016] [Accepted: 10/11/2016] [Indexed: 10/20/2022]
|
50
|
Fanali C, D'Orazio G, Fanali S, Gentili A. Advanced analytical techniques for fat-soluble vitamin analysis. Trends Analyt Chem 2017. [DOI: 10.1016/j.trac.2016.12.001] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|