1
|
Zhang Y, Yuan J, Xu T, Dong L, Ma W, Zhang L, Yin W, Jia S. Total Reflection X-ray Fluorescence Spectrometry: A Comprehensive Review of Critical Components, Analytical Benefits and Practical Applications. Crit Rev Anal Chem 2024:1-20. [PMID: 39388297 DOI: 10.1080/10408347.2024.2411245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/12/2024]
Abstract
Total reflection X-ray fluorescence spectrometry (TXRF) is a pivotal technique in modern atomic spectroscopy, distinguished by its capability for multi-element simultaneous determination, a wide dynamic concentration range, samples do not require acid digestion. Additionally, TXRF exhibits negligible matrix effects when samples are prepared as thin films. Based on these unique features, recent research efforts have increasingly employed laboratory-built TXRF systems for the determination of major and trace elements in various samples. Given the diverse and intricate nature of TXRF systems components, this paper provides an overview of critical components that constitute these systems, compares the influence of various parameters on analytical performance, and offers recommendations for component selection. Additionally, recent applications of laboratory-built TXRF in fields such as environmental monitoring, nuclear energy, and food safety are discussed, with a focus on sample preparation, analyzed elements, and quantitative analysis are presented together with analytical parameters such as detection limits and recoveries. By introducing the instrument components and their practical applications, this paper aims to guide researchers in the construction and optimization of TXRF systems, thereby promoting the advancement of TXRF in future research and practical applications.
Collapse
Affiliation(s)
- Yongsheng Zhang
- State Key Laboratory of Quantum Optics and Quantum Optics Devices, Institute of Laser Spectroscopy, Shanxi University, Taiyuan, China
- Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, China
| | - Jian Yuan
- Beijing Research Institute of Uranium Geology, Beijing, China
| | - Tao Xu
- School of Physics and Energy, Fujian Normal University, Fuzhou, China
| | - Lei Dong
- State Key Laboratory of Quantum Optics and Quantum Optics Devices, Institute of Laser Spectroscopy, Shanxi University, Taiyuan, China
- Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, China
| | - Weiguang Ma
- State Key Laboratory of Quantum Optics and Quantum Optics Devices, Institute of Laser Spectroscopy, Shanxi University, Taiyuan, China
- Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, China
| | - Lei Zhang
- State Key Laboratory of Quantum Optics and Quantum Optics Devices, Institute of Laser Spectroscopy, Shanxi University, Taiyuan, China
- Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, China
| | - Wangbao Yin
- State Key Laboratory of Quantum Optics and Quantum Optics Devices, Institute of Laser Spectroscopy, Shanxi University, Taiyuan, China
- Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, China
| | - Suotang Jia
- State Key Laboratory of Quantum Optics and Quantum Optics Devices, Institute of Laser Spectroscopy, Shanxi University, Taiyuan, China
- Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, China
| |
Collapse
|
2
|
Sanyal K, Dhara S. Suitability and Applications of Total-Reflection X-Ray Fluorescence Spectrometry for Analytical Characterization of Nuclear Materials. Crit Rev Anal Chem 2024:1-16. [PMID: 38407126 DOI: 10.1080/10408347.2024.2316234] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/27/2024]
Abstract
The suitability and applications of Total reflection X-ray Fluorescence (TXRF) for characterization of nuclear materials are numerous. TXRF has been successfully applied for trace, minor and major determinations of constituents in nuclear materials such as fuel, clad, control rod, coolant, etc. The two major advantages of TXRF i.e. requirement of very small sample for analysis and non-requirement of matrix matched standards, make this technique further more attractive and suitable for nuclear industry. The applications of TXRF for trace analysis in nuclear materials such as fuel, clad, coolant and control rods are described in detail along with its applications for determination of major and speciation studies in TXRF mode.
Collapse
Affiliation(s)
- Kaushik Sanyal
- Fuel Chemistry Division, Bhabha Atomic Research Centre, Mumbai, India
- Homi Bhabha National Institute, Anushakti nagar, Mumbai 400094, India
| | - Sangita Dhara
- Fuel Chemistry Division, Bhabha Atomic Research Centre, Mumbai, India
- Homi Bhabha National Institute, Anushakti nagar, Mumbai 400094, India
| |
Collapse
|
3
|
Non-destructive determination of uranium and plutonium in annular (U, Pu)O2 mixed oxide sintered pellets by wavelength dispersive X-ray fluorescence spectrometry. J Radioanal Nucl Chem 2020. [DOI: 10.1007/s10967-020-07309-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
4
|
Sanyal K, Kanrar B, Dhara S, Sibilia M, Sengupta A, Karydas AG, Mishra NL. Direct non-destructive total reflection X-ray fluorescence elemental determinations in zirconium alloy samples. JOURNAL OF SYNCHROTRON RADIATION 2020; 27:1253-1261. [PMID: 32876601 DOI: 10.1107/s1600577520009364] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Accepted: 07/09/2020] [Indexed: 06/11/2023]
Abstract
The development of a direct non-destructive synchrotron-radiation-based total reflection X-ray fluorescence (TXRF) analytical methodology for elemental determinations in zirconium alloy samples is reported for the first time. Discs, of diameter 30 mm and about 1.6 mm thickness, of the zirconium alloys Zr-2.5%Nb and Zircalloy-4 were cut from plates of these alloys and mirror polished. These specimens were presented for TXRF measurements directly after polishing and cleaning. The TXRF measurements were made at the XRF beamline at Elettra synchrotron light source, Trieste, Italy, at two different excitation energies, 1.9 keV and 14 keV, for the determinations of low- and high-Z elements, respectively. The developed analytical methodology involves two complementary quantification schemes, i.e. using either the fundamental parameter method or relative sensitivity based method, allowing quantification of fifteen minor and trace elements with respect to Zr with very good precision and accuracy. In order to countercheck the TXRF analytical results, some samples were analyzed using the DC arc carrier distillation atomic emission spectrometry technique also, which shows an excellent agreement with the results of the TXRF-based methodology developed in this work. The present work resulted in a non-destructive TXRF elemental characterization methodology of metal and alloy samples avoiding the cumbersome dissolution and matrix separation which are normally required in other techniques and traditional methods of TXRF determination. In addition, the production of analytical waste could also be avoided to a large extent. Although the work was carried out for specific applications in the nuclear industry, it is equally suitable for other such samples in different industrial applications.
Collapse
Affiliation(s)
- Kaushik Sanyal
- Fuel Chemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085, India
| | - Buddhadev Kanrar
- Fuel Chemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085, India
| | - Sangita Dhara
- Fuel Chemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085, India
| | - Mirta Sibilia
- IAEA-XRF Beamline, Elettra Sinchotrone Trieste, Trieste, Italy
| | - Arijit Sengupta
- Homi Bhabha National Institute, Anushaktinagar, Mumbai 4000 094, India
| | | | - Nand Lal Mishra
- Fuel Chemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085, India
| |
Collapse
|
5
|
Yadav R, Pandey BN, Kumar A. Estimation and in-situ detection of thorium in human liver cell culture by arsenazo-III based colorimetric assay. Biometals 2020; 33:75-85. [DOI: 10.1007/s10534-019-00231-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Accepted: 12/11/2019] [Indexed: 12/19/2022]
|
6
|
Dhara S, Misra N. Elemental characterization of nuclear materials using total reflection X-ray fluorescence spectrometry. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.04.017] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
7
|
Pandey A, Dhara S, Khan FA, Kelkar A, Kumar P, Bhatt RB, Behere PG. Analysis of Th and U in thorium-based mixed-oxide fuel using wavelength dispersive X-ray fluorescence spectrometer. J Radioanal Nucl Chem 2019. [DOI: 10.1007/s10967-018-6387-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
8
|
Sanyal K, Dhara S, Misra NL. Direct Multielemental Trace Determinations in Plutonium Samples by Total Reflection X-ray Fluorescence Spectrometry Using a Very Small Sample Amount. Anal Chem 2018; 90:11070-11077. [PMID: 30091364 DOI: 10.1021/acs.analchem.8b02917] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A simple, safe, and sensitive method for direct multielemental trace determinations in plutonium samples using total reflection X-ray fluorescence (TXRF) spectrometry has been developed. A very small volume (2 μL) of the sample solutions was deposited on TXRF supports after separation of the plutonium matrix from these solutions. Since the amount of the plutonium deposited on the supports was in the ng level only fixed on the supports and the specimen spots were not disturbed during the sample preparation, the samples could be analyzed directly without putting the instrument in a glovebox. This approach avoided a cumbersome operation of the instrument in a glovebox, which is normally utilized for Pu-based samples using other techniques. Similarly, the requirement of small amounts of the samples minimized the radiation dose to the operator as well as a cumbersome problem of management of radioactive analytical waste of plutonium samples. The samples were analyzed using the TXRF spectra of the specimens, concentration of the internal standard Se or Ga and predetermined sensitivity values. The elemental detection limits for the elements K-Sr varied from 1.06 to 0.09 ng. The elements K, Ca, Cr, Mn, Fe, Ni, Cu, Zn, Sr, Ba, Tl, and Pb were analyzed at μg/mL level. The analytical results of TXRF determinations showed average relative standard deviation (RSD) value of 4.5% (1σ, n = 3) and the TXRF determined results deviated from the expected values by 5.9% on average for samples prepared by adding multielements in plutonium solutions. Two real plutonium samples were also analyzed in similar manner. For the real plutonium sample solution the average RSD values of TXRF determinations were 10.6% (1σ, n = 3) for the elemental concentrations in the range of 0.2 to 61 μg/mL. These values are comparable with conventional trace element analytical techniques with added advantages mentioned above.
Collapse
Affiliation(s)
- Kaushik Sanyal
- Fuel Chemistry Division , Bhabha Atomic Research Centre , Mumbai 400085 , India.,Homi Bhabha National Institute , Mumbai 400094 , India
| | - Sangita Dhara
- Fuel Chemistry Division , Bhabha Atomic Research Centre , Mumbai 400085 , India.,Homi Bhabha National Institute , Mumbai 400094 , India
| | - N L Misra
- Fuel Chemistry Division , Bhabha Atomic Research Centre , Mumbai 400085 , India.,Homi Bhabha National Institute , Mumbai 400094 , India
| |
Collapse
|
9
|
Agarwal R, Sharma MK, Jayachandran K, Gamare JS, Noronha DM, Lohithakshan KV. Poly(3,4-ethylenedioxythiophene)-Poly(styrenesulfonate)-Coated Glassy-Carbon Electrode for Simultaneous Voltammetric Determination of Uranium and Plutonium in Fast-Breeder-Test-Reactor Fuel. Anal Chem 2018; 90:10187-10195. [PMID: 30091590 DOI: 10.1021/acs.analchem.8b00769] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Uranium (U) and plutonium (Pu) contents in nuclear materials must be maintained to a definite level in order to get the desired performance of the fuel inside the reactor. Therefore, high accuracy and precision is an essential criterion for the determination of U and Pu. We already reported the voltammetric determination of Pu in the presence of U in fast-breeder-test-reactor (FBTR) fuel samples, but interfacial, coupled chemical reactions between U(IV) and Pu(IV) enhance the peak-current density of U(VI) reduction and thus make voltammetry unsuitable for the quantitative determination of U in the presence of Pu. Thus, developing a voltammetric method for the simultaneous determination of U and Pu is highly challenging. Herein, we report the simultaneous voltammetric determination of U and Pu in 1 M sulfuric acid (H2SO4) on a poly(3,4-ethylenedioxythiophene) (PEDOT)-poly(styrenesulfonate) (PSS)-modified glassy-carbon (GC) electrode (PEDOT-PSS/GC). The modified electrode shows enhanced performance compared with bare GC electrodes. The peak-current density for U(VI) reduction is enhanced in the presence of Pu(IV), but it attains saturation when [Pu]/[U] in solution is maintained ≥2. Hence, under these circumstances, the variation of Pu concentration no longer influences the U(VI)-reduction peak, and thus the quantitative determination of U in the presence of Pu is possible. No interference is observed from commonly encountered impurities present in FBTR fuel samples. This method shows accuracy and precision comparable to those of the biamperometry method. High robustness, fast analysis, simultaneous determination, reduced radiation exposure to the analyst, and ease of recovery of U and Pu from analytical waste makes it a suitable candidate to substitute the presently applied biamperometry method.
Collapse
Affiliation(s)
- Rahul Agarwal
- Homi Bhabha National Institute , Mumbai 400 094 , India.,Fuel Chemistry Division , Bhabha Atomic Research Centre (BARC) , Trombay, Mumbai 400 085 , India
| | - Manoj K Sharma
- Homi Bhabha National Institute , Mumbai 400 094 , India.,Fuel Chemistry Division , Bhabha Atomic Research Centre (BARC) , Trombay, Mumbai 400 085 , India
| | - Kavitha Jayachandran
- Homi Bhabha National Institute , Mumbai 400 094 , India.,Fuel Chemistry Division , Bhabha Atomic Research Centre (BARC) , Trombay, Mumbai 400 085 , India
| | - Jayashree S Gamare
- Fuel Chemistry Division , Bhabha Atomic Research Centre (BARC) , Trombay, Mumbai 400 085 , India
| | - Donald M Noronha
- Fuel Chemistry Division , Bhabha Atomic Research Centre (BARC) , Trombay, Mumbai 400 085 , India
| | - Kaiprath V Lohithakshan
- Fuel Chemistry Division , Bhabha Atomic Research Centre (BARC) , Trombay, Mumbai 400 085 , India
| |
Collapse
|
10
|
Saha A, Sanyal K, Rawat N, Deb SB, Saxena MK, Tomar BS. Selective Micellar Extraction of Ultratrace Levels of Uranium in Aqueous Samples by Task Specific Ionic Liquid Followed by Its Detection Employing Total Reflection X-ray Fluorescence Spectrometry. Anal Chem 2017; 89:10422-10430. [PMID: 28868888 DOI: 10.1021/acs.analchem.7b02427] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A task specific ionic liquid (TSIL) bearing phosphoramidate group, viz., N-propyl(diphenylphosphoramidate)trimethylammonium bis(trifluoromethanesulfonyl)imide, was synthesized and characterized by 1H NMR, 13C NMR, 31P NMR, and IR spectroscopies, elemental (C H N S) analysis, and electrospray ionization mass spectrometry (ESI-MS). Using this TSIL a cloud point extraction (CPE) or micelle mediated extraction procedure was developed for preconcentration of uranium (U) in environmental aqueous samples. Total reflection X-ray fluorescence spectrometry was utilized to determine the concentration of U in the preconcentrated samples. In order to understand the mechanism of the CPE procedure, complexation study of the TSIL with U was carried out by isothermal calorimetric titration, liquid-liquid extraction, 31P NMR and IR spectroscopies, and ESI-MS. The developed analytical technique resulted in quantitative extraction efficiency of 99.0 ± 0.5% and a preconcentration factor of 99 for U. The linear dynamic range and method detection limit of the procedure were found to be 0.1-1000 ng mL-1 and 0.02 ng mL-1, respectively. The CPE procedure was found to tolerate a higher concentration of commonly available interfering cations and anions, especially the lanthanides. The developed analytical method was validated by determining the concentration of U in a certified reference material, viz., NIST SRM 1640a natural water, which was found to be in good agreement at a 95% confidence limit with the certified value. The method was successfully applied to the U determination in three natural water samples with ≤4% relative standard deviation (1σ).
Collapse
Affiliation(s)
- Abhijit Saha
- Homi Bhabha National Institute , Mumbai 400 094, India
| | | | | | | | | | | |
Collapse
|
11
|
Sanyal K, Khooha A, Das G, Tiwari MK, Misra NL. Direct Determination of Oxidation States of Uranium in Mixed-Valent Uranium Oxides Using Total Reflection X-ray Fluorescence X-ray Absorption Near-Edge Spectroscopy. Anal Chem 2016; 89:871-876. [PMID: 27936602 DOI: 10.1021/acs.analchem.6b03945] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Total reflection X-ray fluorescence (TXRF)-based X-ray absorption near-edge spectroscopy has been used to determine the oxidation state of uranium in mixed-valent U3O8 and U3O7 uranium oxides. The TXRF spectra of the compounds were measured using variable X-ray energies in the vicinity of the U L3 edge in the TXRF excitation mode at the microfocus beamline of the Indus-2 synchrotron facility. The TXRF-based X-ray absorption near-edge spectroscopy (TXRF-XANES) spectra were deduced from the emission spectra measured using the energies below and above the U L3 edge in the XANES region. The data processing using TXRF-XANES spectra of U(IV), U(V), and U(VI) standard compounds revealed that U present in U3O8 is a mixture of U(V) and U(VI), whereas U in U3O7 is mixture of U(IV) and U(VI). The results obtained in this study are similar to that reported in literature using the U M edge. The present study has demonstrated the possibility of application of TXRF for the oxidation state determination and elemental speciation of radioactive substances in a nondestructive manner with very small amount of sample requirement.
Collapse
Affiliation(s)
- Kaushik Sanyal
- Fuel Chemistry Division, Bhabha Atomic Research Centre , Mumbai 400085, India.,Homi Bhabha National Institute , Mumbai 400094, India
| | - Ajay Khooha
- Synchrotrons Utilisation Section, Raja Ramanna Centre for Advanced Technology , Indore 452013, India
| | - Gangadhar Das
- Synchrotrons Utilisation Section, Raja Ramanna Centre for Advanced Technology , Indore 452013, India.,Homi Bhabha National Institute , Mumbai 400094, India
| | - M K Tiwari
- Synchrotrons Utilisation Section, Raja Ramanna Centre for Advanced Technology , Indore 452013, India.,Homi Bhabha National Institute , Mumbai 400094, India
| | - N L Misra
- Fuel Chemistry Division, Bhabha Atomic Research Centre , Mumbai 400085, India.,Homi Bhabha National Institute , Mumbai 400094, India
| |
Collapse
|