1
|
Skiba M, Fatmi S, Elkasri N, Karrout Y, Lahiani-Skiba M. Development, validation and method stability study of a LC-MS method to quantify leuprolide (Hormone analog) in human plasma. J Chromatogr B Analyt Technol Biomed Life Sci 2020; 1160:122345. [PMID: 32920482 DOI: 10.1016/j.jchromb.2020.122345] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2020] [Revised: 08/08/2020] [Accepted: 08/20/2020] [Indexed: 11/16/2022]
Abstract
A rapid, highly sensitive and simple high-performance liquid chromatographic-tandem mass spectrometric (LC-MS) assay is developed and validated for the quantification of leuprolide: a Gonadotropin Releasing Hormone analog (GnRH) in human plasma. Moreover, various parameters of the method stability are determined. After the addition of stable isotope (internal standard), the leuprolide was extracted from human plasma by a C18 solid phase micro extraction (MEPS) cartridge and directly injected into LC-MS/MS system. Chromatographic separation was achieved using a Waters Atlantis HILIC, C18, 150 × 2.1 mm, 5 μ column. Mobile phase was a mixture of acetate buffer (pH 3) and acetonitrile (25/75). Drug detection was performed by MS using electrospray ionization in positive mode. Multiple reaction monitoring (MRM) with a tandem mass spectrometer was used to detect the analytes. Precursor to product ion transitions of: m/z 605.5 → m/z 110.2 and m/z 609.1 → m/z 249.1 were used to quantify leuprolide and leuprolide-13C6-15N, respectively. Sample analysis time was 3 min for each injection. The assay exhibited a linear dynamic range of 0.0500-40 ng/ml for each analyte with a lower limit of quantification (LLOQ) of: 0.0500 ng/ml. Furthermore, a complete analytic validation was carried out, including tests on: The specificity, precision, accuracy, matrix effect and stability under different storage conditions. Importantly, the obtained results established: an acceptable precision and accuracy for concentration over standard curve range. Nevertheless, it is to emphasize the simplicity, rapidity and also the high precision and accuracy of this novel LC-MS method, offering useful information about solution stability. Finally, this work is a good alternative to quantify Leuprolide concentration in human blood, especially on human clinic trials step.
Collapse
Affiliation(s)
- M Skiba
- Normandy UNIV, UNIROUEN, Galenic Pharmaceutical Team, UFR of Health, 22 boulevard Gambetta, 76000 Rouen, France; Normandy UNIV, UNIROUEN, DC2N INSERM U1239, Mont Saint-Aignan, France
| | - S Fatmi
- Normandy UNIV, UNIROUEN, Galenic Pharmaceutical Team, UFR of Health, 22 boulevard Gambetta, 76000 Rouen, France; Technology Pharmaceutical Laboratory, Department of Processes Engineering, Faculty of Technology, Université de Bejaia, 06000 Bejaia, Algeria.
| | - N Elkasri
- Normandy UNIV, UNIROUEN, Galenic Pharmaceutical Team, UFR of Health, 22 boulevard Gambetta, 76000 Rouen, France
| | - Y Karrout
- Univ. Lille, Inserm, CHU Lille, U1008, F-59000 Lille, France
| | - M Lahiani-Skiba
- Normandy UNIV, UNIROUEN, Galenic Pharmaceutical Team, UFR of Health, 22 boulevard Gambetta, 76000 Rouen, France; Normandy UNIV, UNIROUEN, DC2N INSERM U1239, Mont Saint-Aignan, France
| |
Collapse
|
2
|
Controlled release of a model hydrophilic high molecular weight compound from injectable non-lamellar liquid crystal formulations containing different types of phospholipids. Int J Pharm 2020; 577:118944. [DOI: 10.1016/j.ijpharm.2019.118944] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2019] [Revised: 11/18/2019] [Accepted: 12/06/2019] [Indexed: 11/21/2022]
|
3
|
Báez-Santos YM, Otte A, Mun EA, Soh BK, Song CG, Lee YN, Park K. Formulation and characterization of a liquid crystalline hexagonal mesophase region of phosphatidylcholine, sorbitan monooleate, and tocopherol acetate for sustained delivery of leuprolide acetate. Int J Pharm 2016; 514:314-321. [DOI: 10.1016/j.ijpharm.2016.06.138] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2016] [Revised: 06/10/2016] [Accepted: 06/30/2016] [Indexed: 01/23/2023]
|