1
|
Zhang H, Hou W, He Y, Liu Y, Ju Y, Shi X, Zhang Y, Qiao L, He J, Jiang J. Enhanced protection for interfacial lipid ozonolysis by sulfur-containing amino acids. J Colloid Interface Sci 2024; 677:244-249. [PMID: 39094485 DOI: 10.1016/j.jcis.2024.07.217] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2024] [Revised: 07/10/2024] [Accepted: 07/27/2024] [Indexed: 08/04/2024]
Abstract
Sulfur-containing amino acids have been proposed as drugs for lipid oxidation associated with diseases for a long time, but the molecular-level mechanism on the effectiveness of sulfur-containing amino acids against lipid oxidation remains elusive. In this work, with the interfacial sensitivity mass spectrometry method, oxidation of 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphatidylglycerol (POPG), a widely used model lipid, was significantly inhibited on hung droplet surface in presence of sulfur-containing amino acids, such as cysteine (Cys) and methionine (Met). Both the Cys and Met showed a self-sacrificing protection. The amino acids with -S-R tails (R referring to methyl or t-butyl group) showed more effective against POPG oxidation than those with -SH tails, and this process was not related to the conformations of amino acids. The low effectiveness of Cys during the interfacial chemistry was proved to arise from the formation of disulfide bond. This study extends the current understanding of chemistry of sulfur-containing amino acids and provides insights to aid the sulfur-containing amino acids against cell oxidation.
Collapse
Affiliation(s)
- Hong Zhang
- School of Marine Science and Technology, Harbin Institute of Technology at Weihai, Weihai, Shandong 264209, China; State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin, Heilongjiang 150090, China
| | - Wenhao Hou
- School of Marine Science and Technology, Harbin Institute of Technology at Weihai, Weihai, Shandong 264209, China; Marine College, Shandong University, Weihai, Shandong 264209, China
| | - Yuwei He
- School of Marine Science and Technology, Harbin Institute of Technology at Weihai, Weihai, Shandong 264209, China
| | - Yaqi Liu
- School of Marine Science and Technology, Harbin Institute of Technology at Weihai, Weihai, Shandong 264209, China
| | - Yun Ju
- School of Marine Science and Technology, Harbin Institute of Technology at Weihai, Weihai, Shandong 264209, China; State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin, Heilongjiang 150090, China
| | - Xiaohui Shi
- School of Marine Science and Technology, Harbin Institute of Technology at Weihai, Weihai, Shandong 264209, China
| | - Yuexin Zhang
- School of Marine Science and Technology, Harbin Institute of Technology at Weihai, Weihai, Shandong 264209, China
| | - Lina Qiao
- Marine College, Shandong University, Weihai, Shandong 264209, China
| | - Jing He
- School of Marine Science and Technology, Harbin Institute of Technology at Weihai, Weihai, Shandong 264209, China; State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin, Heilongjiang 150090, China.
| | - Jie Jiang
- School of Marine Science and Technology, Harbin Institute of Technology at Weihai, Weihai, Shandong 264209, China; State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin, Heilongjiang 150090, China
| |
Collapse
|
2
|
He J, Zhang H, Liu Y, Ju Y, He Y, Jiang Y, Jiang J. Interfacial Extraction to Trap and Characterize the Criegee Intermediates from Phospholipid Ozonolysis. Anal Chem 2023; 95:5018-5023. [PMID: 36840931 DOI: 10.1021/acs.analchem.2c05472] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/26/2023]
Abstract
Criegee intermediates (CIs) play a significant role in cell membrane peroxidation, but their identification remains elusive at the molecular level. Herein, we combined interfacial extraction and sonic spray ionization mass spectrometry to study the oxidation reaction of 1-palmitoyl-2-oleoyl-sn-glycero-3-phospho-(1'-rac-glycerol) (POPG) mediated by ozone (O3) at/near the surface of a hung water droplet. On-line interfacial extraction and ionization provided a snapshot of the short-lived CIs. Experiments in which the content of water was varied provided evidence for the formation of CIs, which has not been previously observed. Capture experiments using 5,5-dimethyl-pyrroline N-oxide (DMPO) indicated that CIs could be selectively characterized, and the extracted ion current (EICs) of CIs vs DMPO-CI adducts further confirmed the successful observation of CIs. Theoretical calculation suggested that surface ozonolysis of POPG was mainly mediated by anti-CI. These results open a new route for aqueous surface reactive species identification, and benefit toward the understanding of disease development associated with cell oxidative stress mediated by CIs.
Collapse
Affiliation(s)
- Jing He
- School of Marine Science and Technology, Harbin Institute of Technology (Weihai), Weihai 264209, Shandong, China
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin 150090, Heilongjiang, China
| | - Hong Zhang
- School of Marine Science and Technology, Harbin Institute of Technology (Weihai), Weihai 264209, Shandong, China
- State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin 150090, Heilongjiang, China
| | - Yaqi Liu
- School of Marine Science and Technology, Harbin Institute of Technology (Weihai), Weihai 264209, Shandong, China
| | - Yun Ju
- School of Marine Science and Technology, Harbin Institute of Technology (Weihai), Weihai 264209, Shandong, China
| | - Yuwei He
- School of Marine Science and Technology, Harbin Institute of Technology (Weihai), Weihai 264209, Shandong, China
| | - Yanxiao Jiang
- School of Marine Science and Technology, Harbin Institute of Technology (Weihai), Weihai 264209, Shandong, China
| | - Jie Jiang
- School of Marine Science and Technology, Harbin Institute of Technology (Weihai), Weihai 264209, Shandong, China
- State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin 150090, Heilongjiang, China
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin 150090, Heilongjiang, China
| |
Collapse
|
3
|
Li X, Chen MM, Su HF, Zhang ML, Xie SY, Zheng LS. Real-Time Sniffing Mass Spectrometry Aided by Venturi Self-Pumping Applicable to Gaseous and Solid Surface Analysis. Anal Chem 2022; 94:13719-13727. [PMID: 36173369 DOI: 10.1021/acs.analchem.2c01759] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Based on the Venturi self-pumping effect, real-time sniffing with mass spectrometry (R-sniffing MS) is developed as a tool for direct and real-time mass spectrometric analysis of both gaseous and solid samples. It is capable of dual-mode operation in either gaseous or solid phase, with the corresponding techniques termed as Rg-sniffing MS and Rs-sniffing MS, respectively. In its gaseous mode, Rg-sniffing MS is capable of analyzing a gaseous mixture with response time (0.8-2.1 s rise time and 7.3-9.6 s fall time), spatial resolution (<80 μm), three-dimensional diffusion imaging, and aroma distribution imaging of red pepper. In its solid mode, an appropriate solvent droplet desorbs the sample from a solid surface, followed by the aspiration of the mixture using the Venturi self-pumping effect into the mass spectrometer, wherein it is ionized by a standard ion source. Compared with the desorption electrospray ionization (DESI) technique, Rs-sniffing MS demonstrated considerably improved limit of detection (LOD) values for arginine (0.07 μg/cm2 Rs-sniffing vs 1.47 μg/cm2 DESI), thymopentin (0.10 μg/cm2 vs 2.67 μg/cm2), and bacitracin (0.16 μg/cm2 vs 2.28 μg/cm2). Rs-sniffing is applicable for the detection of C60(OCH3)6Cl-, an intermediate in the methoxylation reaction involving C60Cl6 (solid) and methanol (liquid). The convenient and highly sensitive R-sniffing MS has a characteristic separation of desorption from the ionization process, in which the matrix atmosphere of desorption can be interfaced by a pipe channel and self-pumped by the Venturi effect with consequent integration using a standard ion source. The R-sniffing MS operates in a voltage-, heat-, and vibration-free environment, wherein the analyte is ionized by a standard ion source. Consequently, a wide range of samples can be analyzed simultaneously by the R-sniffing MS technique, regardless of their physical state.
Collapse
Affiliation(s)
- Xiang Li
- State Key Laboratory for Physical Chemistry of Solid Surfaces, Collaborative Innovation Center of Chemistry for Energy Materials, Department of Chemistry, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Miao-Miao Chen
- State Key Laboratory for Physical Chemistry of Solid Surfaces, Collaborative Innovation Center of Chemistry for Energy Materials, Department of Chemistry, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Hai-Feng Su
- State Key Laboratory for Physical Chemistry of Solid Surfaces, Collaborative Innovation Center of Chemistry for Energy Materials, Department of Chemistry, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Mei-Lin Zhang
- State Key Laboratory for Physical Chemistry of Solid Surfaces, Collaborative Innovation Center of Chemistry for Energy Materials, Department of Chemistry, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Su-Yuan Xie
- State Key Laboratory for Physical Chemistry of Solid Surfaces, Collaborative Innovation Center of Chemistry for Energy Materials, Department of Chemistry, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Lan-Sun Zheng
- State Key Laboratory for Physical Chemistry of Solid Surfaces, Collaborative Innovation Center of Chemistry for Energy Materials, Department of Chemistry, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| |
Collapse
|
4
|
Shen B, Yang X, Noll SE, Yang X, Liu Y, Jia S, Zhao J, Zheng S, Zare RN, Zhong H. Cell-Based Ambient Venturi Autosampling and Matrix-Assisted Laser Desorption Ionization Mass Spectrometric Imaging of Secretory Products. Anal Chem 2022; 94:3456-3466. [PMID: 35157418 DOI: 10.1021/acs.analchem.1c03625] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A cell-based ambient Venturi autosampling device was established for the monitoring of dynamic cell secretions in response to chemical stimulations in real time with temporal resolution on the order of a second. Detection of secretory products of cells and screening of bioactive compounds are primarily performed on an ambient autosampling probe and matrix-assisted laser desorption ionization (MALDI) mass spectrometry. It takes advantage of the Venturi effect in which the fluid flowing through an inlet capillary tube is automatically fed into a parallel array of multiple outlet capillaries. Cells are incubated inside the inlet capillary tube that is connected with either a syringe pump or liquid chromatography (LC) for the transfer of single compounds or mixtures, respectively. Secretory products were continuously pushed into the outlet capillaries and then spotted into a compressed thin film of the matrix material 9-aminoacridine for MALDI mass spectrometric imaging. In physiological pH, without the use of high voltages and without the use of chemical derivatizations, this platform can be applied to the direct assay of neurotransmitters or other secretory products released from cells in response to the stimulation of individual compounds or LC-separated eluates of natural mixtures. It provides a new way to identify bioactive compounds with a detection limit down to 0.04 fmol/pixel.
Collapse
Affiliation(s)
- Baojie Shen
- Laboratory of Mass Spectrometry, College of Chemistry, Key Laboratory of Pesticides and Chemical Biology, Central China Normal University, Ministry of Education, Wuhan, Hubei 430079, P. R. China
| | - Xiaoyu Yang
- Laboratory of Mass Spectrometry, College of Chemistry, Key Laboratory of Pesticides and Chemical Biology, Central China Normal University, Ministry of Education, Wuhan, Hubei 430079, P. R. China
| | - Sarah Elizabeth Noll
- Department of Chemistry, Stanford University, Stanford, California 94305, United States
| | - Xiaojie Yang
- Laboratory of Mass Spectrometry, College of Chemistry, Key Laboratory of Pesticides and Chemical Biology, Central China Normal University, Ministry of Education, Wuhan, Hubei 430079, P. R. China
| | - Yanping Liu
- Laboratory of Mass Spectrometry, College of Chemistry, Key Laboratory of Pesticides and Chemical Biology, Central China Normal University, Ministry of Education, Wuhan, Hubei 430079, P. R. China
| | - Shanshan Jia
- Laboratory of Mass Spectrometry, College of Chemistry, Key Laboratory of Pesticides and Chemical Biology, Central China Normal University, Ministry of Education, Wuhan, Hubei 430079, P. R. China
| | - Jiaxing Zhao
- State Key Laboratory for Conservation and Utilization of Subtropical Agro-Bioresources, College of Life Science and Technology, Guangxi University, Nanning, Guangxi 530004, P. R. China
| | - Shi Zheng
- Laboratory of Mass Spectrometry, College of Chemistry, Key Laboratory of Pesticides and Chemical Biology, Central China Normal University, Ministry of Education, Wuhan, Hubei 430079, P. R. China
| | - Richard N Zare
- Department of Chemistry, Stanford University, Stanford, California 94305, United States
| | - Hongying Zhong
- Laboratory of Mass Spectrometry, College of Chemistry, Key Laboratory of Pesticides and Chemical Biology, Central China Normal University, Ministry of Education, Wuhan, Hubei 430079, P. R. China.,State Key Laboratory for Conservation and Utilization of Subtropical Agro-Bioresources, College of Life Science and Technology, Guangxi University, Nanning, Guangxi 530004, P. R. China
| |
Collapse
|
5
|
Sun J, Yin Y, Li W, Jin O, Na N. CHEMICAL REACTION MONITORING BY AMBIENT MASS SPECTROMETRY. MASS SPECTROMETRY REVIEWS 2022; 41:70-99. [PMID: 33259644 DOI: 10.1002/mas.21668] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Revised: 10/16/2020] [Accepted: 10/22/2020] [Indexed: 06/12/2023]
Abstract
Chemical reactions conducted in different media (liquid phase, gas phase, or surface) drive developments of versatile techniques for the detection of intermediates and prediction of reasonable reaction pathways. Without sample pretreatment, ambient mass spectrometry (AMS) has been applied to obtain structural information of reactive molecules that differ in polarity and molecular weight. Commercial ion sources (e.g., electrospray ionization, atmospheric pressure chemical ionization, and direct analysis in real-time) have been reported to monitor substrates and products by offline reaction examination. While the interception or characterization of reactive intermediates with short lifetime are still limited by the offline modes. Notably, online ionization technologies, with high tolerance to salt, buffer, and pH, can achieve direct sampling and ionization of on-going reactions conducted in different media (e.g., liquid phase, gas phase, or surface). Therefore, short-lived intermediates could be captured at unprecedented timescales, and the reaction dynamics could be studied for mechanism examinations without sample pretreatments. In this review, via various AMS methods, chemical reaction monitoring and mechanism elucidation for different classifications of reactions have been reviewed. The developments and advances of common ionization methods for offline reaction monitoring will also be highlighted.
Collapse
Affiliation(s)
- Jianghui Sun
- Key Laboratory of Radiopharmaceuticals Ministry of Education, College of Chemistry, Beijing Normal University, Beijing, People's Republic of China
| | - Yiyan Yin
- Key Laboratory of Radiopharmaceuticals Ministry of Education, College of Chemistry, Beijing Normal University, Beijing, People's Republic of China
| | - Weixiang Li
- Key Laboratory of Radiopharmaceuticals Ministry of Education, College of Chemistry, Beijing Normal University, Beijing, People's Republic of China
| | - Ouyang Jin
- Key Laboratory of Radiopharmaceuticals Ministry of Education, College of Chemistry, Beijing Normal University, Beijing, People's Republic of China
| | - Na Na
- Key Laboratory of Radiopharmaceuticals Ministry of Education, College of Chemistry, Beijing Normal University, Beijing, People's Republic of China
| |
Collapse
|
6
|
Liu J, Yu K, Zhang H, He J, Jiang J, Luo H. Mass spectrometric detection of fleeting neutral intermediates generated in electrochemical reactions. Chem Sci 2021; 12:9494-9499. [PMID: 34349924 PMCID: PMC8278903 DOI: 10.1039/d1sc01385h] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Accepted: 06/09/2021] [Indexed: 11/23/2022] Open
Abstract
Towards the goal of on-line monitoring of transient neutral intermediates during electrochemical reactions, an electrochemistry-neutral reionization-mass spectrometry (EC-NR-MS) technique was developed in this work. The EC-NR setup consisted of a customized EC flow cell, a sonic spray ionization source, a heating tube, an ion deflector and an electrospray ionization source, which were respectively used for the precise control of the electrochemical reaction, solution nebulization, droplet desolvation, ion deflection and neutral intermediate ionization. Based on the EC-NR-MS approach, some long-sought neutral radicals including TPrA˙, DBAE˙ and TEOA˙, which belong to important reductive intermediates in electrochemiluminescence (ECL) reactions, were successfully identified which helps to clarify the previously unproven ECL reaction mechanism. These findings were also supported by spin-trapping experiments and the tandem MS technique. Accordingly, the EC-NR-MS method provides a direct solution for studying complicated electrochemical reactions, especially for detecting short-lived neutral radicals as well as ionic intermediates. An electrochemistry-neutral reionization-mass spectrometry (EC-NR-MS) technique was developed for on-line studying the long-sought neutral radicals generated in electrochemical reactions.![]()
Collapse
Affiliation(s)
- Jilin Liu
- School of Environment, School of Marine Science and Technology (Weihai), Harbin Institute of Technology Weihai Shandong 150090 China .,State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology Harbin Heilongjiang 150090 China.,School of Chemistry and Chemical Engineering, Harbin Institute of Technology Harbin Heilongjiang 150001 China
| | - Kai Yu
- School of Environment, School of Marine Science and Technology (Weihai), Harbin Institute of Technology Weihai Shandong 150090 China .,State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology Harbin Heilongjiang 150090 China
| | - Hong Zhang
- School of Environment, School of Marine Science and Technology (Weihai), Harbin Institute of Technology Weihai Shandong 150090 China .,State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology Harbin Heilongjiang 150090 China
| | - Jing He
- School of Environment, School of Marine Science and Technology (Weihai), Harbin Institute of Technology Weihai Shandong 150090 China .,State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology Harbin Heilongjiang 150090 China.,School of Chemistry and Chemical Engineering, Harbin Institute of Technology Harbin Heilongjiang 150001 China
| | - Jie Jiang
- School of Environment, School of Marine Science and Technology (Weihai), Harbin Institute of Technology Weihai Shandong 150090 China .,State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology Harbin Heilongjiang 150090 China.,School of Chemistry and Chemical Engineering, Harbin Institute of Technology Harbin Heilongjiang 150001 China
| | - Hai Luo
- Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University Beijing 100871 China
| |
Collapse
|
7
|
Morato NM, Holden DT, Cooks RG. High‐Throughput Label‐Free Enzymatic Assays Using Desorption Electrospray‐Ionization Mass Spectrometry. Angew Chem Int Ed Engl 2020. [DOI: 10.1002/ange.202009598] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Affiliation(s)
- Nicolás M. Morato
- Department of Chemistry Purdue University 560 Oval Drive West Lafayette IN 47907 USA
| | - Dylan T. Holden
- Department of Chemistry Purdue University 560 Oval Drive West Lafayette IN 47907 USA
| | - R. Graham Cooks
- Department of Chemistry Purdue University 560 Oval Drive West Lafayette IN 47907 USA
| |
Collapse
|
8
|
Morato NM, Holden DT, Cooks RG. High‐Throughput Label‐Free Enzymatic Assays Using Desorption Electrospray‐Ionization Mass Spectrometry. Angew Chem Int Ed Engl 2020; 59:20459-20464. [PMID: 32735371 DOI: 10.1002/anie.202009598] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2020] [Indexed: 01/04/2023]
Affiliation(s)
- Nicolás M. Morato
- Department of Chemistry Purdue University 560 Oval Drive West Lafayette IN 47907 USA
| | - Dylan T. Holden
- Department of Chemistry Purdue University 560 Oval Drive West Lafayette IN 47907 USA
| | - R. Graham Cooks
- Department of Chemistry Purdue University 560 Oval Drive West Lafayette IN 47907 USA
| |
Collapse
|
9
|
Ranganathan N, Li C, Suder T, Karanji AK, Li X, He Z, Valentine SJ, Li P. Capillary Vibrating Sharp-Edge Spray Ionization (cVSSI) for Voltage-Free Liquid Chromatography-Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2019; 30:824-831. [PMID: 30793264 PMCID: PMC6560627 DOI: 10.1007/s13361-019-02147-0] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/27/2018] [Revised: 01/11/2019] [Accepted: 01/30/2019] [Indexed: 05/11/2023]
Abstract
Here, we report a continuous flow-based ionization method, capillary vibrating sharp-edge spray ionization (cVSSI), that nebulizes liquid sample directly at the outlet of a capillary without using high-speed nebulization gas or a high electrical field. cVSSI is built upon the recently reported VSSI principle which nebulizes bulk liquid using vibrating sharp-edges. By attaching a short piece of fused silica capillary on top of the vibrating glass slide in VSSI, liquid is nebulized at the outlet of the capillary as the result of the vibration. Utilizing standard 360-μm OD/100-μm ID capillary, cVSSI works with a wide range of flow rates from 1 μL/min to 1 mL/min. The power consumption is as low as 130 mW. ESI-like MS spectra are obtained for small molecules, peptides, and proteins. Five orders of magnitude linear response for acetaminophen solution is achieved with a limit of detection (LOD) of 3 nM. cVSSI is also demonstrated to be compatible with LC-MS analysis. Two LC-MS applications are demonstrated with cVSSI: (1) separation and detection of a mixture of small molecules and (2) bottom-up proteomics using a protein digest. A mixture of nine common metabolites was appropriately separated and detected using LC-cVSSI-MS. In the bottom-up experiment, 78 peptides were detected using LC-cVSSI-MS/MS with a protein coverage of 100% for cytochrome c, which is comparable with the coverage obtained using LC-ESI-MS. cVSSI offers a means of interfacing LC or other continuous flow-based applications to mass spectrometers with the salient features of voltage-free, flexibility, small footprint, and low power consumption.
Collapse
Affiliation(s)
- Nandhini Ranganathan
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Chong Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | | | - Ahmad K Karanji
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Xiaojun Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Ziyi He
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Stephen J Valentine
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA.
| | - Peng Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA.
| |
Collapse
|
10
|
Progress of Sonic-Spray Ionization Mass Spectrometry and Its Applications. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2019. [DOI: 10.1016/s1872-2040(18)61132-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
|
11
|
Wingen LM, Finlayson-Pitts BJ. Probing surfaces of atmospherically relevant organic particles by easy ambient sonic-spray ionization mass spectrometry (EASI-MS). Chem Sci 2018; 10:884-897. [PMID: 30774883 PMCID: PMC6346289 DOI: 10.1039/c8sc03851a] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2018] [Accepted: 11/01/2018] [Indexed: 12/12/2022] Open
Abstract
EASI-MS is a promising technique for probing the chemical structures of inhomogeneous airborne organic particles.
Both ambient and laboratory-generated particles can have a surface composition different from the bulk, but there are currently few analytical techniques available to probe these differences. Easy ambient sonic-spray ionization mass spectrometry (EASI-MS) was applied to solid, laboratory-generated particles with core–shell morphologies formed from a variety of dicarboxylic acids. The soft ionization facilitated parent peak detection for the two compounds, from which the depth probed could be determined from the relative signal intensities. Two different configurations of a custom-made nebulizer are reported that yield different probe depths. In the “orthogonal mode,” with the nebulizer ∼10 centimeters away from the particle stream and at a 90° angle to the MS inlet, evaporation of the nebulizer droplets forms ions before interaction with the particles. The probe depth for orthogonal mode EASI-MS is shown to be 2–4 nm in these particle systems. In the “droplet mode”, the nebulizer and particle streams are in close proximity to each other and the MS inlet so that the particles interact with charged liquid droplets. This configuration resulted in full dissolution of the particles and gives particle composition similar to that from collection on filters and extraction of the particles (bulk). These studies establish that EASI-MS is a promising technique for probing the chemical structures of inhomogeneous airborne organic particles.
Collapse
Affiliation(s)
- L M Wingen
- Department of Chemistry , University of California Irvine , Irvine , CA 92697-2025 , USA . ; Tel: +1-949-824-7670
| | - B J Finlayson-Pitts
- Department of Chemistry , University of California Irvine , Irvine , CA 92697-2025 , USA . ; Tel: +1-949-824-7670
| |
Collapse
|
12
|
Abstract
Ambient mass spectrometry has evolved rapidly over the past decade, yielding a plethora of platforms and demonstrating scientific advancements across a range of fields from biological imaging to rapid quality control. These techniques have enabled real-time detection of target analytes in an open environment with no sample preparation and can be coupled to any mass analyzer with an atmospheric pressure interface; capabilities of clear interest to the defense, customs and border control, transportation security, and forensic science communities. This review aims to showcase and critically discuss advances in ambient mass spectrometry for the trace detection of explosives.
Collapse
Affiliation(s)
- Thomas P Forbes
- National Institute of Standards and Technology, Materials Measurement Science Division, Gaithersburg, MD, USA.
| | | |
Collapse
|
13
|
van der Sluis R, Ungerer V, Nortje C, A van Dijk A, Erasmus E. New insights into the catalytic mechanism of human glycine N-acyltransferase. J Biochem Mol Toxicol 2017; 31. [PMID: 28759163 DOI: 10.1002/jbt.21963] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2017] [Revised: 06/13/2017] [Accepted: 07/03/2017] [Indexed: 01/30/2023]
Abstract
Even though the glycine conjugation pathway was one of the first metabolic pathways to be discovered, this pathway remains very poorly characterized. The bi-substrate kinetic parameters of a recombinant human glycine N-acyltransferase (GLYAT, E.C. 2.3.1.13) were determined using the traditional colorimetric method and a newly developed HPLC-ESI-MS/MS method. Previous studies analyzing the kinetic parameters of GLYAT, indicated a random Bi-Bi and/or ping-pong mechanism. In this study, the hippuric acid concentrations produced by the GLYAT enzyme reaction were analyzed using the allosteric sigmoidal enzyme kinetic module. Analyses of the initial rate (v) against substrate concentration plots, produced a sigmoidal curve (substrate activation) when the benzoyl-CoA concentrations was kept constant, whereas the plot with glycine concentrations kept constant, passed through a maximum (substrate inhibition). Thus, human GLYAT exhibits mechanistic kinetic cooperativity as described by the Ferdinand enzyme mechanism rather than the previously assumed Michaelis-Menten reaction mechanism.
Collapse
Affiliation(s)
- Rencia van der Sluis
- Human Metabolomics, Biochemistry Division, North-West University, Potchefstroom, 2520, South Africa
| | - Vida Ungerer
- Human Metabolomics, Biochemistry Division, North-West University, Potchefstroom, 2520, South Africa
| | - Carla Nortje
- Human Metabolomics, Biochemistry Division, North-West University, Potchefstroom, 2520, South Africa
| | - Alberdina A van Dijk
- Human Metabolomics, Biochemistry Division, North-West University, Potchefstroom, 2520, South Africa
| | - Elardus Erasmus
- Human Metabolomics, Biochemistry Division, North-West University, Potchefstroom, 2520, South Africa
| |
Collapse
|
14
|
|
15
|
Enhanced aerodynamic reach of vapor and aerosol sampling for real-time mass spectrometric detection using Venturi-assisted entrainment and ionization. Anal Chim Acta 2017; 957:20-28. [PMID: 28107830 DOI: 10.1016/j.aca.2016.12.037] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2016] [Revised: 12/20/2016] [Accepted: 12/25/2016] [Indexed: 11/21/2022]
Abstract
Venturi-assisted ENTrainment and Ionization (VENTI) was developed, demonstrating efficient entrainment, collection, and transport of remotely sampled vapors, aerosols, and dust particulate for real-time mass spectrometry (MS) detection. Integrating the Venturi and Coandă effects at multiple locations generated flow and analyte transport from non-proximate locations and more importantly enhanced the aerodynamic reach at the point of collection. Transport through remote sampling probes up to 2.5 m in length was achieved with residence times on the order of 10-2 s to 10-1 s and Reynolds numbers on the order of 103 to 104. The Venturi-assisted entrainment successfully enhanced vapor collection and detection by greater than an order of magnitude at 20 cm stand-off (limit of simple suction). This enhancement is imperative, as simple suction restricts sampling to the immediate vicinity, requiring close proximity to the vapor source. In addition, the overall aerodynamic reach distance was increased by approximately 3-fold over simple suction under the investigated conditions. Enhanced aerodynamic reach was corroborated and observed with laser-light sheet flow visualization and schlieren imaging. Coupled with atmospheric pressure chemical ionization (APCI), the detection of a range of volatile chemical vapors; explosive vapors; explosive, narcotic, and mustard gas surrogate (methyl salicylate) aerosols; and explosive dust particulate was demonstrated. Continuous real-time Venturi-assisted monitoring of a large room (approximately 90 m2 area, 570 m3 volume) was demonstrated for a 60-min period without the remote sampling probe, exhibiting detection of chemical vapors and methyl salicylate at approximately 3 m stand-off distances within 2 min of exposure.
Collapse
|