1
|
Bouza M, Ahlmann N, García-Reyes JF, Franzke J. Solvent-Assisted Laser Desorption Flexible Microtube Plasma Mass Spectrometry for Direct Analysis of Dried Samples on Paper. Anal Chem 2023; 95:18370-18378. [PMID: 37902451 PMCID: PMC10733904 DOI: 10.1021/acs.analchem.3c03009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 09/11/2023] [Accepted: 10/20/2023] [Indexed: 10/31/2023]
Abstract
The present study investigated the potential for solvent-assisted laser desorption coupled with flexible microtube plasma ionization mass spectrometry (SALD-FμTP-MS) as a rapid analytical technique for direct analysis of surface-deposited samples. Paper was used as the demonstrative substrate, and an infrared hand-held laser was employed for sample desorption, aiming to explore cost-effective sampling and analysis methods. SALD-FμTP-MS offers several advantages, particularly for biofluid analysis, including affordability, the ability to analyze low sample volumes (<10 μL), expanded chemical coverage, sample and substrate stability, and in situ analysis and high throughput potential. The optimization process involved exploring the use of viscous solvents with high boiling points as liquid matrices. This approach aimed to enhance desorption and ionization efficiencies. Ethylene glycol (EG) was identified as a suitable solvent, which not only improved sensitivity but also ensured substrate stability during analysis. Furthermore, the addition of cosolvents such as acetonitrile/water (1:1) and ethyl acetate further enhanced sensitivity and reproducibility for a standard solution containing amphetamine, imazalil, and cholesterol. Optimized conditions for reproducible and sensitive analysis were determined as 1000 ms of laser exposure time using a 1 μL solvent mixture of 60% EG and 40% acetonitrile (ACN)/water (1:1). A mixture of 60% EG and 40% ACN/water (1:1) resulted in signal enhancements and relative standard deviations of 12, 20, and 13% for the evaluated standards, respectively. The applicability of SALD-FμTP-MS was further evaluated by successfully analyzing food, water, and biological samples, highlighting the potential of SALD-FμTP-MS analysis, particularly for thermolabile and polarity diverse compounds.
Collapse
Affiliation(s)
- Marcos Bouza
- Analytical
Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, 23071 Jaén, Spain
| | - Norman Ahlmann
- ISAS—Leibniz
Institut für Analytische Wissenschaften, Bunsen-Kirchhoff-Str. 11, 44139 Dortmund, Germany
| | - Juan F. García-Reyes
- Analytical
Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, 23071 Jaén, Spain
| | - Joachim Franzke
- ISAS—Leibniz
Institut für Analytische Wissenschaften, Bunsen-Kirchhoff-Str. 11, 44139 Dortmund, Germany
| |
Collapse
|
2
|
A portable tool for colorimetric detection of corrosion inhibitors using paper-based analytical devices. Microchem J 2022. [DOI: 10.1016/j.microc.2022.108024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
3
|
Microfluidic paper-based analytical devices and electromembrane extraction; Hyphenation of fields towards effective analytical platforms. Anal Chim Acta 2022; 1216:339987. [DOI: 10.1016/j.aca.2022.339987] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2022] [Revised: 05/17/2022] [Accepted: 05/22/2022] [Indexed: 11/19/2022]
|
4
|
Zhang GL, Zhang M, Shi Q, Jiang Z, Tong L, Chen Z, Tang B. In Situ Construction of COF-Based Paper Serving as a Plasmonic Substrate for Enhanced PSI-MS Detection of Polycyclic Aromatic Hydrocarbons. ACS APPLIED MATERIALS & INTERFACES 2021; 13:43438-43448. [PMID: 34465082 DOI: 10.1021/acsami.1c13860] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Accurate detection, quantitation, and differentiation of polycyclic aromatic hydrocarbons (PAHs) and their isomers in diverse samples is elusive for paper spray ionization mass spectrometry (PSI-MS). To address these issues, herein, for the first time, we propose to fabricate a novel, flexible, and stable paper substrate based on covalent organic frameworks (COFs) via an in situ method under room temperature in air. After embedding gold nanoparticles (AuNPs), this paper substrate (COFs-paper) could further serve as a multifunctional plasmonic matrix (AuNPs-COFs-paper) for dual-wavelength laser-assisted PSI-MS detection of PAHs and feasible paper surface-enhanced Raman scattering (pSERS)-aided isomer discrimination. Taking advantage of the synergistic effect between the AuNPs and COFs present on the novel AuNP-embedded COFs-paper substrate, a satisfied LOD of 0.50 ng/μL for phenanthrene was realized, which improved almost 300 times compared with the naked-paper matrix, and the regression coefficient R2 was up to 0.999. Real sample corn oil-containing PAHs can be efficiently detected and identified using this technique. The established platform has promising potential for on-site chemical analysis with portable PSI-MS and pSERS instruments.
Collapse
Affiliation(s)
- Guang-Lu Zhang
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Institute of Biomedical Sciences, Shandong Normal University, Jinan 250014, P. R. China
| | - Minmin Zhang
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Institute of Biomedical Sciences, Shandong Normal University, Jinan 250014, P. R. China
| | - Qian Shi
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Institute of Biomedical Sciences, Shandong Normal University, Jinan 250014, P. R. China
| | - Zhongyao Jiang
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Institute of Biomedical Sciences, Shandong Normal University, Jinan 250014, P. R. China
| | - Lili Tong
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Institute of Biomedical Sciences, Shandong Normal University, Jinan 250014, P. R. China
| | - Zhenzhen Chen
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Institute of Biomedical Sciences, Shandong Normal University, Jinan 250014, P. R. China
| | - Bo Tang
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Institute of Biomedical Sciences, Shandong Normal University, Jinan 250014, P. R. China
| |
Collapse
|
5
|
Zhang X, Liu S, Wei X, Yu YL, Wang JH. A Novel Pretreatment Device Integrating Magnetic-Assisted Dispersive Extraction and Ultrasonic Spray Separation for Speciation Analysis of Arsenic in Whole Blood by Ion Chromatography-Inductively Coupled Plasma-Mass Spectrometry. Anal Chem 2021; 93:10577-10583. [PMID: 34283582 DOI: 10.1021/acs.analchem.1c01745] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Speciation analysis of arsenic in blood is essential for identifying and quantifying the exposure of arsenic and studying the metabolism and toxicity of arsenic. Herein, a novel pretreatment device is rationally designed and used for speciation analysis of arsenic in whole blood by ion chromatography-inductively coupled plasma-mass spectrometry (IC-ICP-MS). The sample centrifuge tubes containing blood, reagents, and a magnetic stir bar are placed on the fidget spinner of the pretreatment device. When flicking the fidget spinner rotation with the finger, the magnetic stir bar in the tube rotates in three dimensions under the magnetic field, thereby assisting dispersive extraction of arsenic species by the mixing of blood with reagents. Afterward, the arsenic extract is separated in situ from the blood matrix using an ultrasonic spray sheet covered with a filter and ultrafiltration membrane, which is directly used for subsequent IC-ICP-MS analysis. For 100 μL of blood, the whole pretreatment operation can be completed within 10 min. With As(III), As(V), MMA, and DMA in blood as analytes, the use of the present pretreatment device will hardly lead to the loss and transformation of arsenic species, and the extraction efficiency of the total arsenic is more than 96%. When the pretreatment device is coupled to IC-ICP-MS, the detection limits of four arsenic species in whole blood are 0.017-0.023 μg L-1, and precisions are within 2.3-4.2%. This pretreatment device provides a simple, fast, efficient, and low-cost tool for extraction and separation of arsenic species in whole blood, opening a new idea for the pretreatment of complex samples.
Collapse
Affiliation(s)
- Xiao Zhang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Shuang Liu
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Xing Wei
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Yong-Liang Yu
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Jian-Hua Wang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| |
Collapse
|
6
|
Yuan H, Chiu PY, Chen CF. Paper-based analytical devices for point-of-care blood tests. BIOMICROFLUIDICS 2021; 15:041303. [PMID: 34326913 PMCID: PMC8310430 DOI: 10.1063/5.0055601] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Accepted: 07/11/2021] [Indexed: 05/28/2023]
Abstract
Blood can be a window to health, and as a result, is the most intensively studied human biofluid. Blood tests can diagnose diseases, monitor therapeutic drugs, and provide information about the health of an individual. Rapid response blood tests are becoming increasingly essential, especially when subsequent treatment is required. Toward this need, paper-based devices have been excellent tools for performing blood tests due to their ability to conduct rapid and low-cost diagnostics and analyses in a non-laboratory environment. In this Perspective, we review recent advances in paper-based blood tests, particularly focusing on the specific techniques and assays applied. Additionally, we discuss the future of these paper-based devices, such as how the signal intensity can be enhanced and how the in situ synthesis of nanomaterials can be used to improve the sensitivity, functionality, and operational simplicity. With these advances, paper-based devices are becoming increasingly valuable tools for point-of-care blood tests in various practical scenarios.
Collapse
Affiliation(s)
- Hao Yuan
- Institute of Applied Mechanics, National Taiwan University, Taipei 106, Taiwan
| | | | - Chien-Fu Chen
- Institute of Applied Mechanics, National Taiwan University, Taipei 106, Taiwan
| |
Collapse
|
7
|
Frey BS, Damon DE, Badu-Tawiah AK. Emerging trends in paper spray mass spectrometry: Microsampling, storage, direct analysis, and applications. MASS SPECTROMETRY REVIEWS 2020; 39:336-370. [PMID: 31491055 PMCID: PMC7875099 DOI: 10.1002/mas.21601] [Citation(s) in RCA: 49] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2019] [Accepted: 07/22/2019] [Indexed: 05/20/2023]
Abstract
Recent advancements in the sensitivity of chemical instrumentation have led to increased interest in the use of microsamples for translational and biomedical research. Paper substrates are by far the most widely used media for biofluid collection, and mass spectrometry is the preferred method of analysis of the resultant dried blood spot (DBS) samples. Although there have been a variety of review papers published on DBS, there has been no attempt to unify the century old DBS methodology with modern applications utilizing modified paper and paper-based microfluidics for sampling, storage, processing, and analysis. This critical review will discuss how mass spectrometry has expanded the utility of paper substrates from sample collection and storage, to direct complex mixture analysis to on-surface reaction monitoring.
Collapse
Affiliation(s)
| | | | - Abraham K. Badu-Tawiah
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210
| |
Collapse
|
8
|
Boobphahom S, Nguyet Ly M, Soum V, Pyun N, Kwon OS, Rodthongkum N, Shin K. Recent Advances in Microfluidic Paper-Based Analytical Devices toward High-Throughput Screening. Molecules 2020; 25:E2970. [PMID: 32605281 PMCID: PMC7412548 DOI: 10.3390/molecules25132970] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Revised: 06/17/2020] [Accepted: 06/19/2020] [Indexed: 02/06/2023] Open
Abstract
Microfluidic paper-based analytical devices (µPADs) have become promising tools offering various analytical applications for chemical and biological assays at the point-of-care (POC). Compared to traditional microfluidic devices, µPADs offer notable advantages; they are cost-effective, easily fabricated, disposable, and portable. Because of our better understanding and advanced engineering of µPADs, multistep assays, high detection sensitivity, and rapid result readout have become possible, and recently developed µPADs have gained extensive interest in parallel analyses to detect biomarkers of interest. In this review, we focus on recent developments in order to achieve µPADs with high-throughput capability. We discuss existing fabrication techniques and designs, and we introduce and discuss current detection methods and their applications to multiplexed detection assays in relation to clinical diagnosis, drug analysis and screening, environmental monitoring, and food and beverage quality control. A summary with future perspectives for µPADs is also presented.
Collapse
Affiliation(s)
- Siraprapa Boobphahom
- Metallurgy and Materials Science Research Institute, Chulalongkorn University, Soi Chula 12, Phayathai Road, Pathumwan, Bangkok 10330, Thailand;
| | - Mai Nguyet Ly
- Department of Chemistry and Institute of Biological Interfaces, Sogang University, Seoul 04107, Korea; (M.N.L.); (V.S.); (N.P.); (O.-S.K.)
| | - Veasna Soum
- Department of Chemistry and Institute of Biological Interfaces, Sogang University, Seoul 04107, Korea; (M.N.L.); (V.S.); (N.P.); (O.-S.K.)
| | - Nayoon Pyun
- Department of Chemistry and Institute of Biological Interfaces, Sogang University, Seoul 04107, Korea; (M.N.L.); (V.S.); (N.P.); (O.-S.K.)
| | - Oh-Sun Kwon
- Department of Chemistry and Institute of Biological Interfaces, Sogang University, Seoul 04107, Korea; (M.N.L.); (V.S.); (N.P.); (O.-S.K.)
| | - Nadnudda Rodthongkum
- Metallurgy and Materials Science Research Institute, Chulalongkorn University, Soi Chula 12, Phayathai Road, Pathumwan, Bangkok 10330, Thailand;
| | - Kwanwoo Shin
- Department of Chemistry and Institute of Biological Interfaces, Sogang University, Seoul 04107, Korea; (M.N.L.); (V.S.); (N.P.); (O.-S.K.)
| |
Collapse
|
9
|
Swiner DJ, Jackson S, Burris BJ, Badu-Tawiah AK. Applications of Mass Spectrometry for Clinical Diagnostics: The Influence of Turnaround Time. Anal Chem 2020; 92:183-202. [PMID: 31671262 PMCID: PMC7896279 DOI: 10.1021/acs.analchem.9b04901] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
This critical review discusses how the need for reduced clinical turnaround times has influenced chemical instrumentation. We focus on the development of modern mass spectrometry (MS) and its application in clinical diagnosis. With increased functionality that takes advantage of novel front-end modifications and computational capabilities, MS can now be used for non-traditional clinical analyses, including applications in clinical microbiology for bacteria differentiation and in surgical operation rooms. We summarize here recent developments in the field that have enabled such capabilities, which include miniaturization for point-of-care testing, direct complex mixture analysis via ambient ionization, chemical imaging and profiling, and systems integration.
Collapse
Affiliation(s)
- Devin J. Swiner
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210
| | - Sierra Jackson
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210
| | - Benjamin J. Burris
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210
| | - Abraham K. Badu-Tawiah
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210
| |
Collapse
|
10
|
Song C, Gao D, Li S, Liu L, Chen X, Jiang Y. Determination and quantification of fatty acid C=C isomers by epoxidation reaction and liquid chromatography-mass spectrometry. Anal Chim Acta 2019; 1086:82-89. [PMID: 31561797 DOI: 10.1016/j.aca.2019.08.023] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2019] [Revised: 08/08/2019] [Accepted: 08/14/2019] [Indexed: 12/14/2022]
Abstract
The location of double bond in unsaturated fatty acids (FAs) plays a critical role in their physiological properties. However, structural identification and quantification of unsaturated FAs by mass spectrometry are still challenging. In this work, we reported the coupling of epoxidation reaction of the C=C in unsaturated FAs and liquid chromatography-mass spectrometry (LC-MS) with multiple reaction monitoring (MRM) mode for accurate identification and quantification of C=C isomers of FAs. Epoxidation of the C=C in unsaturated FAs was induced by a dioxide of ketone, tetrahydrothiopyran-4-one 1,1-dioxide, as a catalyst and Oxone as an oxidant in less than 5 min with nearly 100% yield. All the C=C bonds were epoxidized to obtain a single product, simplifying the chromatographic separation of epoxidation products to enable more accurate quantification analysis. The epoxidation products were stable at room temperature and can produce highly abundant diagnostic ions indicative of C=C locations by tandem mass spectrometry using collision-induced association (CID). The application of this approach for the analysis of FAs isomers in human plasma demonstrated the potential of our method for the qualitative and quantitative analysis of unsaturated FAs in complex biological samples, which is valuable in biological and medical analysis.
Collapse
Affiliation(s)
- Chao Song
- State Key Laboratory of Chemical Oncogenomics, Graduate School at Shenzhen, Tsinghua University, Shenzhen, Guangdong, 518055, China
| | - Dan Gao
- State Key Laboratory of Chemical Oncogenomics, Graduate School at Shenzhen, Tsinghua University, Shenzhen, Guangdong, 518055, China.
| | - Shangfu Li
- State Key Laboratory of Chemical Oncogenomics, Graduate School at Shenzhen, Tsinghua University, Shenzhen, Guangdong, 518055, China
| | - Liping Liu
- Department of Hepatobiliary and Pancreatic Surgery, Shenzhen People's Hospital, Second Clinical Medical College of Jinan University, 1017 North of Dongmen Road, Shenzhen, Guangdong Province, 518000, China
| | - Xiaowu Chen
- Shenzhen Kivita Innovative Drug Discovery Institute, Shenzhen, 518110, China
| | - Yuyang Jiang
- State Key Laboratory of Chemical Oncogenomics, Graduate School at Shenzhen, Tsinghua University, Shenzhen, Guangdong, 518055, China; School of Pharmaceutical Sciences, Tsinghua University, Beijing, 100084, China.
| |
Collapse
|
11
|
Li L, Geng Y, Xiang Y, Qiang H, Wang Y, Chang J, Zhao H, Zhang L. Instrument-free enrichment and detection of phosphopeptides using paper-based Phos-PAD. Anal Chim Acta 2019; 1062:102-109. [DOI: 10.1016/j.aca.2019.02.019] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2019] [Accepted: 02/05/2019] [Indexed: 01/24/2023]
|
12
|
Chen C, Zhao L, Zhang H, Shen X, Zhu Y, Chen H. Novel Wax Valves To Improve Distance-Based Analyte Detection in Paper Microfluidics. Anal Chem 2019; 91:5169-5175. [DOI: 10.1021/acs.analchem.8b05764] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Affiliation(s)
| | - Litao Zhao
- Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China
| | - Han Zhang
- Department of Biological Engineering, Utah State University, 4105 Old Main Hill, Logan, Utah 84322, United States
| | | | - Yonggang Zhu
- School of Science, RMIT University Melbourne, Victoria 3001, Australia
| | | |
Collapse
|
13
|
Abstract
Paper has unique advantages over other materials, including low cost, flexibility, porosity, and self-driven liquid pumping, thus making it widely used in various fields in biology, chemistry, physics and materials science.
Collapse
Affiliation(s)
- Bingbing Gao
- School of Pharmaceutical Sciences
- Nanjing Tech University
- Nanjing 211816
- China
| | - Xin Li
- School of Pharmaceutical Sciences
- Nanjing Tech University
- Nanjing 211816
- China
| | - Yaqiong Yang
- School of Pharmaceutical Sciences
- Nanjing Tech University
- Nanjing 211816
- China
| | - Jianlin Chu
- School of Pharmaceutical Sciences
- Nanjing Tech University
- Nanjing 211816
- China
| | - Bingfang He
- School of Pharmaceutical Sciences
- Nanjing Tech University
- Nanjing 211816
- China
| |
Collapse
|
14
|
Liu H, Gao W, Tian Y, Liu A, Wang Z, Cai Y, Zhao Z. Rapidly detecting tetrabromobisphenol A in soils and sediments by paper spray ionization mass spectrometry combined with isotopic internal standard. Talanta 2019; 191:272-276. [DOI: 10.1016/j.talanta.2018.08.069] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2018] [Revised: 08/22/2018] [Accepted: 08/27/2018] [Indexed: 01/02/2023]
|
15
|
Gold nanoparticles-enhanced ion-transmission mass spectrometry for highly sensitive detection of chemical warfare agent simulants. Talanta 2018; 190:403-409. [PMID: 30172526 DOI: 10.1016/j.talanta.2018.08.021] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2018] [Revised: 07/31/2018] [Accepted: 08/05/2018] [Indexed: 01/01/2023]
Abstract
Gold nanoparticles (AuNPs)-embedded paper was coupled with ion-transmission mass spectrometry (MS) to enable the highly sensitive detection of chemical warfare agent (CWA) simulants in solutions. With the assistance of a low-temperature plasma (LTP) probe, we found that AuNPs were capable to enhance the ionization efficiencies of target analytes, with MS signal intensities surprisingly undergone an 800-fold increase under optimized conditions. The interaction between AuNPs and the radiofrequency electromagnetic field was believed to promote the desorption/ionization process, resulting in the unusual signal enhancement phenomenon. Based on this finding, we established a method for the rapid analysis of two simulants of nerve agents, dimethyl methylphosphonate (DMMP) and diisopropyl methylphosphonate (DIMP), with a dynamic range from 0.5 ng/mL to 100 ng/mL and detection limits of 0.1 ng/mL and 0.3 ng/mL, respectively. As sample pretreatments have been eliminated, the developed strategy is particularly promising for the on-site detection of CWAs considering its simple and rapid analytical workflow.
Collapse
|
16
|
ZHANG XL, ZHANG H, WANG XC, HUANG KK, WANG D, CHEN HW. Advances in Ambient Ionization for Mass Spectrometry. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2018. [DOI: 10.1016/s1872-2040(18)61122-3] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
17
|
Fu LM, Wang YN. Detection methods and applications of microfluidic paper-based analytical devices. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2018.08.018] [Citation(s) in RCA: 154] [Impact Index Per Article: 25.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
18
|
Zhang H, He J, Qiao L, Yu K, Li N, You H, Jiang J. Doped Argon Surface Desorption Dielectric-Barrier Discharge Ionization Mass Spectrometry for Fragile Compounds. Anal Chem 2018; 90:9033-9039. [PMID: 29966414 DOI: 10.1021/acs.analchem.8b01304] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Argon surface desorption dielectric-barrier discharge ionization (Ar-SDDBDI) in conjunction with dopants was reported for rapid and sensitive determining of fragile compounds. In dopant/Ar-SDDBDI, analytes are ionized primarily through proton transfer with dopant ions, which are formed in Ar plasma. Different from He, dopant/Ar-SDDBDI generates low energetic ions, and therefore, fragmentation is suppressed. It thus significantly simplifies the mass spectra and the assignment of one peak. Dopants ranging from organic solvents to gaseous materials were systematically studied. The application of dopant/Ar-SDDBDI was demonstrated by analysis of multiple compounds, including antibiotics, amino acids, fatty acids, hormones, pharmaceuticals, and peptides. Rapid profiling of chemicals in such complex matrixes including mixtures and drug tablets was also tested. Positive and negative mass spectra with little to no fragmentation for compounds in the pure state and as mixtures were readily achieved. Limits of detection (S/N = 3) were determined to be 0.60 and 0.36 pmol, respectively, for the analysis of l-alanine and metronidazole. Furthermore, the demonstration applications also included imaging of an "H" character under ambient conditions. These results indicate that the technique by combining of Ar-SDDBDI with dopants exhibits high sensitivity, high spatial resolution, and a very low degree of fragmentation, which render it a potential tool for fragile compound analysis in mass spectrometry imaging.
Collapse
Affiliation(s)
- Hong Zhang
- School of Municipal and Environmental Engineering and State Key Laboratory of Urban Water Resource and Environment , Harbin Institute of Technology , Harbin , Heilongjiang 150090 , P. R. China
| | - Jing He
- School of Marine Science and Technology , Harbin Institute of Technology at Weihai , Weihai , Shandong 264209 , P. R. China
| | - Lina Qiao
- School of Municipal and Environmental Engineering and State Key Laboratory of Urban Water Resource and Environment , Harbin Institute of Technology , Harbin , Heilongjiang 150090 , P. R. China
| | - Kai Yu
- School of Marine Science and Technology , Harbin Institute of Technology at Weihai , Weihai , Shandong 264209 , P. R. China
| | - Na Li
- School of Marine Science and Technology , Harbin Institute of Technology at Weihai , Weihai , Shandong 264209 , P. R. China
| | - Hong You
- School of Marine Science and Technology , Harbin Institute of Technology at Weihai , Weihai , Shandong 264209 , P. R. China.,School of Municipal and Environmental Engineering and State Key Laboratory of Urban Water Resource and Environment , Harbin Institute of Technology , Harbin , Heilongjiang 150090 , P. R. China
| | - Jie Jiang
- School of Marine Science and Technology , Harbin Institute of Technology at Weihai , Weihai , Shandong 264209 , P. R. China
| |
Collapse
|
19
|
Zhao X, Zhao Y, Zhang L, Ma X, Zhang S, Zhang X. Rapid Analysis of Unsaturated Fatty Acids on Paper-Based Analytical Devices via Online Epoxidation and Ambient Mass Spectrometry. Anal Chem 2018; 90:2070-2078. [PMID: 29272100 DOI: 10.1021/acs.analchem.7b04312] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Affiliation(s)
- Xu Zhao
- Beijing
Key Laboratory for Microanalytical Methods and Instrumentation, Department
of Chemistry, Tsinghua University, Beijing 100084, People’s Republic of China
| | - Yaoyao Zhao
- Graduate
School of Health Science, Hokkaido University, North 12, West 5, Kita-ku, Sapporo 060-0812, Japan
| | - Lin Zhang
- Beijing
Key Laboratory for Microanalytical Methods and Instrumentation, Department
of Chemistry, Tsinghua University, Beijing 100084, People’s Republic of China
- State Key Laboratory of NBC Protection for Civilian, Beijing 102205, People’s Republic of China
| | - Xiaoxiao Ma
- State
Key Laboratory of Precision Measurement Technology and Instruments,
Department of Precision Instrument, Tsinghua University, Beijing 100084, People’s Republic of China
| | - Sichun Zhang
- Beijing
Key Laboratory for Microanalytical Methods and Instrumentation, Department
of Chemistry, Tsinghua University, Beijing 100084, People’s Republic of China
| | - Xinrong Zhang
- Beijing
Key Laboratory for Microanalytical Methods and Instrumentation, Department
of Chemistry, Tsinghua University, Beijing 100084, People’s Republic of China
| |
Collapse
|
20
|
Hecht M, Evard H, Takkis K, Veigure RT, Aro R, Lohmus R, Herodes K, Leito I, Kipper K. Sponge Spray-Reaching New Dimensions of Direct Sampling and Analysis by MS. Anal Chem 2017; 89:11592-11597. [PMID: 29028329 DOI: 10.1021/acs.analchem.7b02957] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Sample preparation for the analysis of clinical samples with the mass spectrometer (MS) can be extensive and expensive. Simplifying and speeding up the process would be very beneficial. This paper reports sponge spray-a novel sampling and direct MS analysis approach-attempting exactly that. It enables direct analysis without any sample preparation from dried blood, plasma, and urine. The tip of a volumetric absorptive microsampling device is used to collect an exact amount of sample and from that same tip an electrospray can be directed into a mass spectrometer. We demonstrate here that, although with significant matrix effects, quantitation of penicillin G, a common antimicrobial, is possible in plasma and in urine, with essentially no sample preparation.
Collapse
Affiliation(s)
- Max Hecht
- University of Tartu , Institute of Chemistry, 14a Ravila Street, 50411 Tartu, Estonia
| | - Hanno Evard
- University of Tartu , Institute of Chemistry, 14a Ravila Street, 50411 Tartu, Estonia.,Faculty of Pharmacy, Division of Pharmaceutical Chemistry and Technology, University of Helsinki , Viikinkaari 5, 00790 Helsinki, Finland
| | - Kalev Takkis
- University of Tartu , Institute of Chemistry, 14a Ravila Street, 50411 Tartu, Estonia
| | - Ru Ta Veigure
- University of Tartu , Institute of Chemistry, 14a Ravila Street, 50411 Tartu, Estonia
| | - Rudolf Aro
- University of Tartu , Institute of Chemistry, 14a Ravila Street, 50411 Tartu, Estonia
| | - Rynno Lohmus
- University of Tartu , Institute of Physics, W. Ostwaldi Street 1, 50411 Tartu, Estonia
| | - Koit Herodes
- University of Tartu , Institute of Chemistry, 14a Ravila Street, 50411 Tartu, Estonia
| | - Ivo Leito
- University of Tartu , Institute of Chemistry, 14a Ravila Street, 50411 Tartu, Estonia
| | - Karin Kipper
- University of Tartu , Institute of Chemistry, 14a Ravila Street, 50411 Tartu, Estonia.,Paediatric Infectious Diseases Research Group, Institute for Infection and Immunity, St. George's, University of London , Cranmer Terrace, London SW17 0RE, United Kingdom.,Analytical Services International, St George's University of London , Cranmer Terrace, London SW17 0RE, United Kingdom
| |
Collapse
|
21
|
Zhao Y, Zhao H, Zhao X, Jia J, Ma Q, Zhang S, Zhang X, Chiba H, Hui SP, Ma X. Identification and Quantitation of C═C Location Isomers of Unsaturated Fatty Acids by Epoxidation Reaction and Tandem Mass Spectrometry. Anal Chem 2017; 89:10270-10278. [PMID: 28837768 DOI: 10.1021/acs.analchem.7b01870] [Citation(s) in RCA: 71] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Affiliation(s)
- Yaoyao Zhao
- Graduate
School of Health Science, Hokkaido University, North 12, West 5, Kita-ku, Sapporo 060-0812, Japan
| | - Hansen Zhao
- Department
of Chemistry, Tsinghua University, Beijing 100084, P.R. China
| | - Xu Zhao
- Department
of Chemistry, Tsinghua University, Beijing 100084, P.R. China
| | - Jia Jia
- Department
of Chemistry, Tsinghua University, Beijing 100084, P.R. China
| | - Qiang Ma
- Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| | - Sichun Zhang
- Department
of Chemistry, Tsinghua University, Beijing 100084, P.R. China
| | - Xinrong Zhang
- Department
of Chemistry, Tsinghua University, Beijing 100084, P.R. China
| | - Hitoshi Chiba
- Graduate
School of Health Science, Hokkaido University, North 12, West 5, Kita-ku, Sapporo 060-0812, Japan
| | - Shu-Ping Hui
- Graduate
School of Health Science, Hokkaido University, North 12, West 5, Kita-ku, Sapporo 060-0812, Japan
| | - Xiaoxiao Ma
- Department
of Precision Instruments, Tsinghua University, Beijing 100084, P.R. China
| |
Collapse
|
22
|
Nanthasurasak P, Cabot JM, See HH, Guijt RM, Breadmore MC. Electrophoretic separations on paper: Past, present, and future-A review. Anal Chim Acta 2017; 985:7-23. [DOI: 10.1016/j.aca.2017.06.015] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2017] [Revised: 06/01/2017] [Accepted: 06/06/2017] [Indexed: 12/15/2022]
|
23
|
Dumlao M, Khairallah GN, Donald WA. Internal Energy Deposition in Dielectric Barrier Discharge Ionization is Significantly Lower than in Direct Analysis in Real-Time Mass Spectrometry. Aust J Chem 2017. [DOI: 10.1071/ch17440] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
The extent of internal energy deposition using three different plasma-based ionization mass spectrometry (MS) methods, atmospheric pressure chemical ionization (APCI), direct analysis in real time (DART), and active capillary dielectric barrier discharge ionization (DBDI), was investigated using benzylammonium ‘thermometer’ ions. Ions formed by DBDI were activated significantly less than those that were formed by DART and APCI under these conditions. Thermal ion activation by DART can be reduced slightly by positioning the DART source further from the capillary entrance to the MS and reducing the heat that is applied to metastable atoms exiting the DART source. For example, the average ion internal energy distribution decreased by less than 10 % (166.9 ± 0.3 to 152.2 ± 1.0 kJ mol−1) when the distance between the DART source and the MS was increased by 250 % (10 to 25 mm). By lowering the DART temperature from 350 to 150°C, the internal energy distributions of the thermometer ions decreased by ~15 % (169.93 ± 0.83 to 150.21 ± 0.52 kJ mol−1). Positioning the DART source nozzle more than 25 mm from the entrance to the MS and decreasing the DART temperature further resulted in a significant decrease in ion signal. Thus, varying the major DART ion source parameters had minimal impact on the ‘softness’ of the DART ion source under these conditions. Overall, these data indicate that DBDI can be a significantly ‘softer’ ion source than two of the most widely used plasma-based ion sources that are commercially available.
Collapse
|