1
|
Zhang Y, Pei C, Zhang J, Cheng C, Lian X, Chen M, Huang B, Fu Z, Zhou Z, Li M. Detection of polycyclic aromatic hydrocarbons using a high performance-single particle aerosol mass spectrometer. J Environ Sci (China) 2023; 124:806-822. [PMID: 36182185 DOI: 10.1016/j.jes.2022.02.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2021] [Revised: 12/14/2021] [Accepted: 02/03/2022] [Indexed: 06/16/2023]
Abstract
The real-time detection of the mixing states of polycyclic aromatic hydrocarbons (PAHs) and nitro-PAHs in ambient particles is of great significance for analyzing the source, aging process, and health effects of PAHs and nitro-PAHs; yet there is still few effective technology to achieve this type of detection. In this study, 11 types of PAH and nitro-PAH standard samples were analyzed using a high performance-single particle aerosol mass spectrometer (HP-SPAMS) in lab studies. The identification principles 'parent ions' and 'mass-to-charge (m/z) = 77' of each compound were obtained in this study. It was found that different laser energies did not affect the identification of the parent ions. The comparative experiments of ambient atmospheric particles, cooking and biomass burning emitted particles with and without the addition of PAHs were conducted and ruled out the interferences from primary and secondary organics on the identification of PAHs. Besides, the reliability of the characteristic ions extraction method was evaluated through the comparative study of similarity algorithm and deep learning algorithm. In addition, the real PAH-containing particles from vehicle exhaust emissions and ambient particles were also analyzed. This study improves the ability of single particle mass spectrometry technology to detect PAHs and nitro-PAHs, and HP-SPAMS was superior to SPAMS for detecting single particles containing PAHs and nitro-PAHs. This study provides support for subsequent ambient observations to identify the characteristic spectrum of single particles containing PAHs and nitro-PAHs.
Collapse
Affiliation(s)
- Yao Zhang
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air pollution, Jinan University, Guangzhou 510632, China; Guangdong-Hongkong-Macau Joint Laboratory of Collaborative Innovation for Environmental Quality, Guangzhou 510632, China
| | - Chenglei Pei
- Guangzhou Environmental Monitoring Center, Guangzhou 510030, China
| | - Jinwen Zhang
- Guangzhou Hexin Analytical Instrument Company Limited, Guangzhou 510530, China
| | - Chunlei Cheng
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air pollution, Jinan University, Guangzhou 510632, China; Guangdong-Hongkong-Macau Joint Laboratory of Collaborative Innovation for Environmental Quality, Guangzhou 510632, China.
| | - Xiufeng Lian
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air pollution, Jinan University, Guangzhou 510632, China; Guangdong-Hongkong-Macau Joint Laboratory of Collaborative Innovation for Environmental Quality, Guangzhou 510632, China
| | - Mubai Chen
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air pollution, Jinan University, Guangzhou 510632, China; Guangdong-Hongkong-Macau Joint Laboratory of Collaborative Innovation for Environmental Quality, Guangzhou 510632, China
| | - Bo Huang
- Guangzhou Hexin Analytical Instrument Company Limited, Guangzhou 510530, China
| | - Zhong Fu
- Guangzhou Hexin Analytical Instrument Company Limited, Guangzhou 510530, China
| | - Zhen Zhou
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air pollution, Jinan University, Guangzhou 510632, China; Guangdong-Hongkong-Macau Joint Laboratory of Collaborative Innovation for Environmental Quality, Guangzhou 510632, China
| | - Mei Li
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air pollution, Jinan University, Guangzhou 510632, China; Guangdong-Hongkong-Macau Joint Laboratory of Collaborative Innovation for Environmental Quality, Guangzhou 510632, China.
| |
Collapse
|
2
|
Azov VA, Mueller L, Makarov AA. LASER IONIZATION MASS SPECTROMETRY AT 55: QUO VADIS? MASS SPECTROMETRY REVIEWS 2022; 41:100-151. [PMID: 33169900 DOI: 10.1002/mas.21669] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Revised: 10/09/2020] [Accepted: 10/12/2020] [Indexed: 06/11/2023]
Abstract
Laser ionization mass spectrometry (LIMS) was one of the first practical methods developed for in situ analysis of the surfaces of solid samples. This review will encompass several aspects related to this analytical method. First, we will discuss the process of laser ionization, the influence of the laser type on its performance, and imaging capabilities of this method. In the second chapter, we will follow the historic development of LIMS instrumentation. After a brief overview of the first-generation instruments developed in 1960-1990 years, we will discuss in detail more recent designs, which appeared during the last 2-3 decades. In the last part of our review, we will cover the recent applications of LIMS for surface analysis. These applications include various types of analyses of solid inorganic, organic, and heterogeneous samples, often in combination with depth profiling and imaging capability.
Collapse
Affiliation(s)
- Vladimir A Azov
- Department of Chemistry, University of the Free State, Bloemfontein, South Africa
| | | | - Alexander A Makarov
- Thermo Fisher Scientific GmbH, Bremen, Germany
- Biomolecular Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular Research, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Utrecht, The Netherlands
| |
Collapse
|
3
|
Chang YP, Devi Y, Chen CH. Micro-droplet Trapping and Manipulation: Understanding Aerosol Better for a Healthier Environment. Chem Asian J 2021; 16:1644-1660. [PMID: 33999498 DOI: 10.1002/asia.202100516] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2021] [Indexed: 11/09/2022]
Abstract
Understanding the physicochemical properties and heterogeneous processes of aerosols is key not only to elucidate the impacts of aerosols on the atmosphere and humans but also to exploit their further applications, especially for a healthier environment. Experiments that allow for spatially control of single aerosol particles and investigations on the fundamental properties and heterogeneous chemistry at the single-particle level have flourished during the last few decades, and significant breakthroughs in recent years promise better control and novel applications aimed at resolving key issues in aerosol science. Here we propose graphene oxide (GO) aerosols as prototype aerosols containing polycyclic aromatic hydrocarbons, and GO can behave as two-dimensional surfactants which could modify the interfacial properties of aerosols. We describe the techniques of trapping single particles and furthermore the current status of the optical spectroscopy and chemistry of GO. The current applications of these single-particle trapping techniques are summarized and interesting future applications of GO aerosols are discussed.
Collapse
Affiliation(s)
- Yuan-Pin Chang
- Department of Chemistry, National Sun Yat-sen University, No. 70 Lien-hai Rd., Kaohsiung, 80424, Taiwan.,Aerosol Science Research Center, National Sun Yat-sen University, No. 70 Lien-hai Rd., Kaohsiung, 80424, Taiwan
| | - Yanita Devi
- Department of Chemistry, National Sun Yat-sen University, No. 70 Lien-hai Rd., Kaohsiung, 80424, Taiwan
| | - Chun-Hu Chen
- Department of Chemistry, National Sun Yat-sen University, No. 70 Lien-hai Rd., Kaohsiung, 80424, Taiwan
| |
Collapse
|
4
|
Affiliation(s)
- Patricia Forbes
- Department of Chemistry, University of Pretoria, Lynnwood Road, Pretoria 0002, South Africa
| |
Collapse
|
5
|
Schade J, Passig J, Irsig R, Ehlert S, Sklorz M, Adam T, Li C, Rudich Y, Zimmermann R. Spatially Shaped Laser Pulses for the Simultaneous Detection of Polycyclic Aromatic Hydrocarbons as well as Positive and Negative Inorganic Ions in Single Particle Mass Spectrometry. Anal Chem 2019; 91:10282-10288. [DOI: 10.1021/acs.analchem.9b02477] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Affiliation(s)
- Julian Schade
- Joint Mass Spectrometry Centre, Chair of Analytical Chemistry, University Rostock, 18059 Rostock, Germany
| | - Johannes Passig
- Joint Mass Spectrometry Centre, Chair of Analytical Chemistry, University Rostock, 18059 Rostock, Germany
- Joint Mass Spectrometry Centre, Cooperation Group ‘Comprehensive Molecular Analytics’ (CMA), Helmholtz Zentrum München, 85764 Neuherberg, Germany
| | - Robert Irsig
- Joint Mass Spectrometry Centre, Chair of Analytical Chemistry, University Rostock, 18059 Rostock, Germany
- Photonion GmbH, 19061 Schwerin, Germany
| | | | - Martin Sklorz
- Joint Mass Spectrometry Centre, Cooperation Group ‘Comprehensive Molecular Analytics’ (CMA), Helmholtz Zentrum München, 85764 Neuherberg, Germany
| | - Thomas Adam
- Joint Mass Spectrometry Centre, Cooperation Group ‘Comprehensive Molecular Analytics’ (CMA), Helmholtz Zentrum München, 85764 Neuherberg, Germany
- Bundeswehr University Munich, 85577 Neubiberg, Germany
| | - Chunlin Li
- Department of Earth and Planetary Sciences, Weizmann Institute of Science, Rehovot 76100, Israel
| | - Yinon Rudich
- Department of Earth and Planetary Sciences, Weizmann Institute of Science, Rehovot 76100, Israel
| | - Ralf Zimmermann
- Joint Mass Spectrometry Centre, Chair of Analytical Chemistry, University Rostock, 18059 Rostock, Germany
- Joint Mass Spectrometry Centre, Cooperation Group ‘Comprehensive Molecular Analytics’ (CMA), Helmholtz Zentrum München, 85764 Neuherberg, Germany
| |
Collapse
|
6
|
Shinoda R, Uchimura T. Evaluating the Creaming of an Emulsion via Mass Spectrometry and UV-Vis Spectrophotometry. ACS OMEGA 2018; 3:13752-13756. [PMID: 31458075 PMCID: PMC6644440 DOI: 10.1021/acsomega.8b02283] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/05/2018] [Accepted: 10/11/2018] [Indexed: 06/10/2023]
Abstract
The creaming behavior of a turbid oil-in-water emulsion was observed via the processes of multiphoton ionization time-of-flight mass spectrometry (MPI-TOFMS) and ultraviolet-visible spectrophotometry (UV-vis), and the results were compared. The transmittance measurement by UV-vis showed that the turbidity of the toluene emulsion was decreased with time. However, non-negligible errors are common in the measurement of a sample with high turbidity. The online measurement by MPI-TOFMS detected many spikes in the time profile, which revealed the existence of toluene droplets in the emulsion. A smooth time profile suggested that the signal intensity had initially increased, and then decreased with time; the initial concentration of toluene was 3 g/L, which had decreased by half after 60 min. The signal behavior obtained using MPI-TOFMS differed only slightly from that obtained using UV-vis. Since a change in turbidity is not the same as a change in the local concentration of an oil component, MPI-TOFMS is useful for the analysis of a turbid emulsion and offers additional information concerning the creaming phenomenon of an emulsion.
Collapse
|
7
|
Determination of Relative Ionization Cross Sections for Resonance Enhanced Multiphoton Ionization of Polycyclic Aromatic Hydrocarbons. APPLIED SCIENCES-BASEL 2018. [DOI: 10.3390/app8091617] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Resonance enhanced multiphoton ionization (REMPI) is a powerful method for the sensitive determination of polycyclic aromatic hydrocarbons (PAHs) in gaseous mixtures via mass spectrometry (MS). In REMPI, ions are produced by the absorption of at least two photons including defined electronic intermediate states. As a result—unlike other laser-based ionization techniques—spectroscopic selectivity is involved into the ionization process. Nevertheless, these wavelength-dependent ionization rates impede the quantification using REMPI. For this purpose, relative photoionization cross sections (relPICS) give an easy-to-use approach to quantify REMPI-MS measurements. Hereby, the ionization behavior of a single compound was compared to that of a reference substance of a given concentration. In this study, relPICS of selected single-core aromatics and PAHs at wavelengths of 266 nm and 248 nm were determined using two different time-of-flight mass spectrometric systems (TOFMS). For PAHs, relPICS were obtained which showed a strong dependence on the applied laser intensity. In contrast, for single-core aromatics, constant values of relPICS were determined. Deviations of relPICS between both TOFMS systems were found for small aromatics (e.g., benzene), which can be assigned to the differences in UV generation in the particular system. However, the relPICS of this study were found to be in good agreement with previous results and can be used for system-independent quantification.
Collapse
|
8
|
Development of Multiphoton Ionization Time-of-Flight Mass Spectrometry for the Detection of Small Emulsion Droplets. APPLIED SCIENCES-BASEL 2018. [DOI: 10.3390/app8030413] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
A system for measuring small oil droplets in an oil-in-water (O/W) emulsion was developed using multiphoton ionization time-of-flight mass spectrometry. In the present study, a capillary column with an inner diameter of 15 µm was used for sample introduction. Moreover, a compact microscopic system was constructed for observing an emulsion flowing through a capillary column. As a result, the length for sample introduction was shortened, which is preferable for the direct evaluation of an emulsion. Using this system, the minimum diameter of a detectable toluene droplet in an O/W emulsion was decreased to 1.7 µm. The present system could be used to evaluate the local microenvironment and stability of an emulsion.
Collapse
|
9
|
Mikuška P, Čapka L, Večeřa Z. Aerosol sampler for analysis of fine and ultrafine aerosols. Anal Chim Acta 2018; 1020:123-133. [PMID: 29655423 DOI: 10.1016/j.aca.2018.02.070] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2017] [Revised: 02/20/2018] [Accepted: 02/23/2018] [Indexed: 11/17/2022]
Abstract
A new aerosol sampler based on the original version of Aerosol Counterflow Two-Jets Unit (ACTJU) is described. The ACTJU collector, connected with a water-based Condensation Growth Unit (CGU) placed upstream of the ACTJU, accomplished the quantitative collection of fine and ultrafine aerosol particles down to a few nanometers in diameter. Condensation of water vapor in the CGU enlarges nanometer sized particles to larger sizes in the supermicrometer range and the formed droplets are then collected into water in the ACTJU collector. The continuous collection of aerosols with the CGU-ACTJU sampler allows for the time-resolved measurement of changes in the concentration of particulate constituents. Coupling of the CGU-ACTJU sampler with on-line detection devices allows in-situ automated analysis of water-soluble aerosol components with high time resolution of 1 s (e.g., FIA detection for nitrite or nitrate) or 1 h (e.g., IC detection with preconcentration step for inorganic anions). Under the optimum conditions (the air flow rate of 10 L min-1 and water flow rate of 1.5 mL min-1), the limit of detection (IC including the preconcentration) for particulate fluoride, chloride, nitrite, nitrate, sulphate and phosphate is 2.53, 6.64, 24.2, 16.8, 0.12 and 5.03 ng m-3, respectively. The apparatus is sufficiently robust for its application at routine monitoring of aerosol composition in real-time.
Collapse
Affiliation(s)
- Pavel Mikuška
- Institute of Analytical Chemistry of the Czech Academy of Sciences, v.v.i., Veveří 97, 602 00 Brno, Czech Republic.
| | - Lukáš Čapka
- Institute of Analytical Chemistry of the Czech Academy of Sciences, v.v.i., Veveří 97, 602 00 Brno, Czech Republic
| | - Zbyněk Večeřa
- Institute of Analytical Chemistry of the Czech Academy of Sciences, v.v.i., Veveří 97, 602 00 Brno, Czech Republic
| |
Collapse
|
10
|
Affiliation(s)
- Julia Laskin
- Department of Chemistry, Purdue University , West Lafayette, Indiana 47907, United States
| | - Alexander Laskin
- Department of Chemistry, Purdue University , West Lafayette, Indiana 47907, United States
| | - Sergey A Nizkorodov
- Department of Chemistry, University of California , Irvine, California 92697, United States
| |
Collapse
|